- Manufacturer: CROUZET
- Product type: Analogue Timers - DIN Rail
- Product Range:MCR1 Series; Timer Functions:Timing After Impulse; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:2
- Current Rating Nom: 8A
- Supply Voltage Max: 240VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 59.28 € |
| Current stock | 25+ |
| Lead time | 30 days |
## Single-Function Analog Timers ## **DIN-Rail Mount 17.5 mm** Chronos2 MAR1, MBR1, MCR1, MHR1 Series _The Chronos 2 range of industrial timers: ideal for timing, monitoring and counting functions. Available in single or multi-function versions, to meet the specific needs of each application._ Electrical Control & Protection > Timer Relays > DIN-Rail > Analog **> Relay Output** ## **Highlights** - Mono-function - Multi-range - Multi-voltage - Screw terminals - Possibility of external load connection in parallel to the control input - 3-wire PNP sensor compatible - Nominal rating 8 A ## **Standards** - LED status indicator ## **Part Numbers** **==> picture [475 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 88827115 88827125 88827135 88827145<br>i a ais bi<br>Functions: A - At Functions B Functions C Functions: H - Ht<br>Series: MAR1 Series: MBR1 Series: MCR1 Series: MHR1<br>**----- End of picture text -----**<br> ## **Part numbering system** ## **More info.** **Product line: Output Type: Power Supply: 88:** Control **0:** Static **3:** 12-240 VAC/DC **1:** Relay **4:** 24-240 VAC or 24-240 VAC/DC **5:** 24 VDC / 24-240 VAC or 24-240 VAC/DC **6:** 230-240 / 380-440 VAC **88 827 1 0 3 Function: 0:** Multifunction U **5:** Function L/Li **Casing: 1:** Function A **6:** Function K **827:** 17.5 mm **865/866:** 22.5 mm **2:** Function B **7:** Function Q **3:** Function C **8:** Multifunction X **4:** Function H/Ht **==> picture [23 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> HERE<br>**----- End of picture text -----**<br> 1 Single-Function Analog Timers ## **Specifications** |**Specifications**|||||| |---|---|---|---|---|---| |**Specifications**||**88827115**|**88827125**|**88827135**|**88827145**| ||||||| |**Inputs**<br>Supply voltage<br>24 VDC / 24-240 VAC<br>~~ME~~<br>eee|||||| ||||||| |Voltage supply tolerance||-15%, +10%|||| ||||||| |Operating factor||1 00%|||| |Max power consumption at Un||0.6 W (24 VDC)<br>1.1 VA (24 VAC)<br>10 VA (120 VAC)<br>28 VA (240 VAC)|||| |Immunity to power micro cuts||< 10 ms|||| |**Timing**<br>eee|||||| |Timing ranges||1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h|||| ||||||| |Minimum control pulse duration||30 ms DC / 50 ms AC|||| ||||||| |Recovery time (after by de-energization)||120 ms|||| |Setting accuracy (full range)||IEC/EN 61812-1: ± 0.5% with constant parameters|||| |Drift temperature||± 0.05% /°C|||| ||||||| |Drift voltage||± 0.2% / V|||| |**Outputs**<br>Outputs configuration<br>1 changeover relay<br>WE<br>eee|||||| |Maximum switching voltage||8 A 250 VAC resistive<br>8 A 30 VDC resistive|||| ||||||| |Maximum switching power (resistive)||250 VAC / 8 A resistive<br>125 VDC / 0.3 A resistive|||| ||||||| |Electrical life (operations)||10⁵<br>8 A 250 VAC resistive|||| ||||||| |Minimum breaking current||10 mA / 5 VDC|||| |Mechanical life (operations)||10x106 cycles|||| |Rated power||2000 VA / 40 W|||| ||||||| |Dielectric strength||IEC/EN 60664-1: 2.5 kV / 1 min / 1 mA / 50 Hz|||| |**Insulation**<br>ee|||||| |Insulation coordination||IEC/EN 60664-1: Voltage surge category III|||| ||||||| |Rated impulse voltage||IEC/EN 60664-1, IEC/EN 61812-1, IEC 62314:2022: 5 kV (1.2/50 μs)|||| |Clearance / creepage distances||IEC/EN 60664-1: 4 kV / 3 mm<br>Pollution degree 2|||| |Insulation resistance||IEC/EN 60664-1: 100 MΩ (500 VDC)|||| 2 ©Crouzet - Technical Datasheet - 9/01/2025 - www.crouzet.com Single-Function Analog Timers ## **Specifications** |**Specifications**||||| |---|---|---|---|---| |**Specifications**||**88827115**<br>**88827125**|**88827135**|**88827145**| |||||| |**General characteristics**||||| |||||| |Display||No, but status indicator.<br>Un: green LED blinks when counting, flashes when not counting, and lights up continously<br>when relay is closed and not counting.||| |Display accuracy||IEC/EN 61812-1: ± 10% / 25°C||| |||||| |Casing||17.5 mm||| |||||| |Mounting||IEC/EN 60715: 35 mm symmetrical DIN-Rail||| |||||| |Mounting position||Vertical||| |||||| |Housing material||Self-extinguishing<br>Incandescent wire test||| |||||| |Degree of protection||According to IEC/EN 60529 :<br>Terminal block : IP20<br>Housing : IP40<br>Front face : IP50||| |||||| |Terminal capacity||Single-wire without ferrule:<br>1x0,5 - 3,3 mm² (AWG 20 - AWG 12)<br>2x0,5 - 2,5 mm² (AWG 20 - AWG 14)<br>Multi-wire with ferrule:<br>1x0.5 - 2.5mm² (AWG20 - AWG14)<br>2x0.5 - 1.5mm² (AWG20 - AWG16)||| |Maximum tightening torques||IEC 60947-1 : 0.5 - 0.6 N.m||| |Operating temperature||-20°C to +60°C||| |Storage temperature||-30°C to +60°C||| |Humidity||IEC/EN 60068-2-30: 93% non-condensing||| |Vibration resistance||IEC/EN 60068-2-6: 20 m/s² / 10 Hz - 150 Hz||| |||||| |Shock resistance||IEC/EN 60068-2-27: 15 g - 11 ms||| |Short interruption on power line||IEC/EN 61000-4-11: 0% residual voltage, 250/300 cycles||| |Weight||63 g||| |Packaging||Paper<br>Compact carton<br>Corrugated carton<br>PE bags (not glued)<br>Molded cellulose pulp (e.g.-box)<br>PET pieces (recyclable)||| |**Standards**||||| |||||| |Approvals / marking||CE, cULus Listed Industrial Control Equipment, CCC*|CE, cULus Listed Industrial Control Equipment, CCC*|| |||||| |Conformity with environmental directives||2015/863/UE: RoHS<br>1907/2006: Reach||| |||||| |Immunity to electrostatic discharges||IEC/EN 61000-4-2: Level III (Air 8 kV / Contact 6 kV)||| |Immunity to radiated, radio-frequency,<br>electromagnetic field||IEC/EN 61000-4-3:<br>Level I (1 V/m: 2.0 GHz - 2.7 GHz)<br>Level II (3 V/m: 1.4 GHz - 2.0 GHz)<br>Level III (10 V/m: 80 MHz - 1 GHz)||| |Immunity to rapid transient bursts||IEC/EN 61000-4-4: Level III (direct 2 kV / Capacitive coupling clamp 1 kV)||| |||||| |Immunity to shock waves on power<br>supply||IEC/EN 61000-4-5: Level III (2 kV / common mode 2 kV / residual current mode 1 kV)||| |Immunity to radiofrequency in common<br>mode||IEC/EN 61000-4-6: Level III (10 Vrms: 0.15 MHz - 80 MHz)||| |||||| |Immunity to voltage dips and breaks||IEC/EN 61000-4-11:<br>0% residual voltage, 1 cycle<br>70% residual voltage, 25/30 cycles||| ©Crouzet - Technical Datasheet - 9/01/2025 - www.crouzet.com 3 Single-Function Analog Timers ## **Dimensions (mm)** **==> picture [246 x 515] intentionally omitted <==** **----- Start of picture text -----**<br> 60 ±0.5<br>44 (MAX)<br>17.9 [+0.5] 0<br>23.1 ±0.25<br>= Ey j<br>5.5 ±0.2<br>3.5 ±0.2<br>= od<br>Wiring diagrams<br>U<br>~__—<br>+<br>A1 Y1 15<br>R<br>A2<br>16 18<br>a e<br>0 0.5- ±0.5 ±0.5<br>90 67.5 45<br>±0.2<br>**----- End of picture text -----**<br> ## **Wiring diagrams** ©Crouzet - Technical Datasheet - 9/01/2025 - www.crouzet.com 4 Single-Function Analog Timers ## **Function diagrams** ## **Function A: On-Delay (Delay on make)** ## **Function C: Off-Delay (Delay on brake)** **==> picture [167 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Function At: Summation Time Relay<br>**----- End of picture text -----**<br> **==> picture [91 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function H: Interval<br>**----- End of picture text -----**<br> ## **Function B: One-Shot** ## **Function Ht: Interval with Memory** **WARNING -** The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products. ©Crouzet - Technical Datasheet - 9/01/2025 - www.crouzet.com 5
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →