XTPR020BC1
ROTARY MOTOR STARTER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Motor Starters
- No. of Poles: 3 Pole
- Power Rating: 15kW
- No. of Phases: Three Phase
- Product Range: XT Line IEC Series
- Current Rating: 20A
- IP / NEMA Rating: IP20
- Motor Starter Type: Manual Starter
- Supply Voltage Max: 690VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 149.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
IEC Contactors and Starters
## **IEC Contactors and Starters**
## **1.1**
|**_XT_ IEC Power Control**<br>Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-2**|**1**|
|---|---|---|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|**1**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**||
|Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|**1**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>C440/**_XT_**Electronic Overload Relay . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-128**<br>**V5-T1-141**|**1**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|**1**|
|Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-191**||
|**_XT_**Electronic Manual Motor Protector . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-217**|**1**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-230**|**1**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**||
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|**1**|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-1**
## Revision notes
Volume 5—Motor Control and Protection, CA08100006E
Tab 1—IEC Contactors and Starters
|**Revision date**||**Section**|**Change page(s)**|**Description**|
|---|---|---|---|---|
|04/07/2017||1.1|V5-T1-232|Newproduct inserted|
**==> picture [140 x 45] intentionally omitted <==**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1** _**XT**_ **IEC Power Control**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .|**V5-T1-217**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . .|**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## **Product Overview**
The _**XT**_ line of IEC power control offers starting and protection solutions ideal for control panels.
Innovations in the design and development allow users to reduce material costs, reduce installation effort, and enhance panel safety and performance all in a compact design. Some of these key innovations include:
- Toolless assembly of manual motor controllers and reversing contactors
- Low coil consumption
- Front accessibility to coil terminations
- Built-in surge suppression on electronic coils
- Built-in auxiliary contact for contactors up to 32A in a 45 mm frame
The _**XT**_ line includes a large offering of power control components and accessories that cover a broad range of applications and ratings:
- Three-pole contactors to 2000A
- Four-pole contactors to 200A
- Capacitor contactors to 680 kVAR
- Mini contactors to 9A
- Relays to 16A
- Thermal overload relays to 630A
- Electronic overload relays to 1500A
- Manual motor protectors to 65A
- Manual motor controllers and combination motor controllers to 65A
- Finger-safe and back-ofhand proof ratings
- Direct PLC control on 185A–2000A contactors
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-2**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **Relays and Timers**
## **Contents**
|**Contents**|||
|---|---|---|
|**Contents**<br>**_Description_**|**_Page_**|**1**|
|Relays and Timers<br>Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-4**|**1**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-5**<br>**V5-T1-6**|**1**|
|Technical Data and Specifications . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-12**<br>**V5-T1-16**|**1**|
|An Eaton<br>Green Solution||**1**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .<br>Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**<br>**V5-T1-35**|**1**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .<br>C440/**_XT_**Electronic Overload Relay . . . . . . . . . . . .|**V5-T1-128**<br>**V5-T1-141**|**1**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .<br>Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-157**<br>**V5-T1-191**|**1**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .<br>EMS—Electronic Motor Starter . . . . . . . . . . . . . . .|**V5-T1-217**<br>**V5-T1-230**|**1**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . .<br>Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**<br>**V5-T1-234**|**1**|
## **Relays and Timers**
## **Product Description**
Eaton’s new line of _**XT**_ relays and timers includes mini and standard frame control relays and auxiliary contacts, mini electronic on-delay and multi-function timers and an electronic star-delta (wye-delta) timer for use in star-delta (wye-delta) combinations. Because _**XT**_ meets UL[®] , CSA[®] and CE standards, it is the perfect product solution for IEC applications all over the world. The compact, space saving and easy to install _**XT**_ line of IEC contactors and starters is the efficient and effective solution for customer applications.
## **Features**
- For use with mini and standard frame size contactors and starters
- Control relays
- AC control from 12V to 550V 50 Hz, 600V 60 Hz
- DC control from 12V to 220V
- On-delay and multifunction timers
- 24–240 Vac/Vdc control
- Available with screw or spring cage terminals
- Four-pole configurations
- IP20 finger and back-ofhand proof
- Large ambient temperature range: –25° to 50°C [–13° to 122°F]
## **Standards and Certifications**
- IEC EN 60947
- CE approved
- UL
- CSA
## _**Instructional Leaflets**_
Pub51219 XTRM Mini Control Relays
Pub51210 XTRE Control Relays Pub51244 XTTR Electronic Star-Delta (Wye-Delta) Timer
Pub51245 XTMT Mini Electronic On-Delay and Multi-Function Timers
- The XTRE control relays have positively driven contacts between the relay and the auxiliary contact modules as well as within the auxiliary contact modules
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-3**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **—Relays**
**==> picture [491 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT RE C 10 B 22 AD<br>Product Line Prefix Coil Code<br>XT = XT IEC power control Product Family Code Contact See table on Page V5-T1-5 .<br>RM = Mini IEC control Terminations Frame Configuration<br>relay Blank = Screw XTRM 40 = 4NO<br>RE = IEC control relay terminals A = 45 mm—mini 31 = 3NO-1NC<br>C = Spring cage XTRE 22 = 2NO-2NC<br>terminals B = 45 mm—standard<br>Conventional Thermal<br>Current Rating<br>10 = 10A<br>**----- End of picture text -----**<br>
**==> picture [48 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT —Timers<br>**----- End of picture text -----**<br>
**==> picture [482 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT MT 6 B 30S 11 B<br>Product Line Prefix Coil Code<br>XT = XT IEC power control Product Family Code Time Range Max. Function B = 24–240 Vac/Vdc<br>MT = Mini IEC timing Conventional XTMT XTMT<br>relay Thermal Current 30S = 1.5–30s 11 = On-delay<br>TR = Electronic timing Rating 60H = 05–1s 70 = Adjustable<br>relay star-delta 6 = 6A 0.15–3s XTTE<br>(wye-delta) 0.5–10s 51 = Star-delta<br>3–60s<br>Frame<br>0.15–3 min<br>A = 45 mm 0.5–3 min<br>3–60 min<br>0.15–3h<br>0.5–3h<br>3–60h<br>XTTR<br>60S = 3–60s<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-4**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Product Selection**
## _**When Ordering**_
- Orders must be placed in multiples of the package quantity listed
- DC operated control relays have a built-in suppressor circuit
- Contact terminal numbers to EN50011
- Coil terminal numbers to EN50005
## **XTRM10A_**
## **Mini Control Relays**
|**Conventional**<br>**Thermal**|**Contact**|**Rated Operational Current**<br>**AC-15 Ie (A)**|**Rated Operational Current**||**Circuit**||||**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|
|**Current Ith (A)**<br>10|**Configuration**<br>4NO|**220–240V**<br>6|**380–415V**<br>3|**500V**<br>1.5|**Symbol**<br>14<br>13<br>33<br>34<br>A1<br>A2<br>23<br>24<br>~~ray~~||43<br>44||**Catalog Number**1<br>**XTRM10A40_**|
|10|3NO-1NC|6|3|1.5|14<br>13 21<br>22<br>33<br>34<br>A1<br>A2<br>~~ae~~|||43<br>44|**XTRM10A31_**|
|10|2NO-2NC|6|3|1.5|14<br>13 21<br>22<br>31<br>32<br>A1<br>A2<br>~~a~~|||43<br>44|**XTRM10A22_**2|
## **Control Relays**
**XTREC10_**
|**XTREC10_**|**Control Relays**|**Control Relays**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|[fe|**Conventional**<br>**Thermal**<br>**Current Open**<br>**at 60°C Ith (A)**<br>16<br>16|**Contact**<br>**Configuration**<br>4NO<br>3NO-1NC|**Rated Operational Current**<br>**AC-15 Ie (A)**<br>**220–240V**<br>**380–415V**<br>6<br>4<br>6<br>4||**500V**<br>1.5<br>1.5|**Circuit**<br>**Symbol**<br>14<br>13<br>33<br>34<br>A1<br>A2<br>23<br>24<br>14<br>13 21<br>22<br>33<br>34<br>A1<br>A2<br>~~oi~~<br>~~an~~||||43<br>44<br>43<br>44|**Screw Terminal**<br>**Catalog Number**1<br>**XTRE10B40_**<br>**XTRE10B31_**|**Spring Cage**<br>**Terminal**<br>**Catalog Number**1<br>**XTREC10B40_**<br>**XTREC10B31_**|
||16|2NO-2NC|6|4|1.5|14<br>13 21<br>22<br>31<br>32<br>43<br>44<br>A1<br>A2<br>~~ate~~|||||**XTRE10B22_**3|**XTREC10B22_**3|
||||||||||||||
|**Coil Voltage Suffix**|||||||||||||
|**Coil Voltage**<br>110V 50 Hz, 120V 60 Hz|**Suffix Code**<br>**A**|**Coil Voltage**<br>415V 50 Hz, 480V 60 Hz|415V 50 Hz, 480V 60 Hz|**Suffix Code**<br>**C**|**Coil Voltage**<br>380V 50 Hz, 440V 60 Hz|||||**Suffix Code**<br>**L**|**Coil Voltage**<br>120 Vdc|**Suffix Code**<br>**AD**|
|220V 50 Hz, 240V 60 Hz|**B**|550V 50 Hz, 600V 60 Hz|550V 50 Hz, 600V 60 Hz|**D**|380V 60 Hz|||||**P**|220 Vdc|**BD**|
|230V 50 Hz|**F**|208V 60 Hz||**E**|12V 50/60 Hz|||||**R**|12 Vdc|**RD**|
|24V 50/60 Hz|**T**|190V 50 Hz, 220V 60 Hz|190V 50 Hz, 220V 60 Hz|**G**|42V 50 Hz, 48V 60 Hz|42V 50 Hz, 48V 60 Hz||||**W**|48 Vdc|**WD**|
|24 Vdc|**TD**|240V 50 Hz, 277V 60 Hz|240V 50 Hz, 277V 60 Hz|**H**|48V 50 Hz|||||**Y**|||
## **Coil Voltage Suffix**
## _**Notes**_
- 1 Underscore (_) indicates magnet coil suffix required. See Coil Voltage Suffix table above.
- 2 DC operated control relays XTRM(C)10A22_ cannot be used with front mount auxiliary contacts.
- 3 DC operated control relays XTRE(C)10B22_ can only be combined with two-pole auxiliary contacts.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-5**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Accessories**
## _**Auxiliary Contacts**_
**XTMCXF_**
## **Front-Mount Auxiliary Contacts for Use with XTRM Mini Control Relays**
|**Conventional**<br>**Thermal Current,**<br>**I th Open (A)**|**Rated Operational Current**<br>**AC-15 Ie (A)**<br>**220V**<br>**230V**<br>**240V**<br>**380V**<br>**400V**<br>**415V**|**Rated Operational Current**<br>**AC-15 Ie (A)**<br>**220V**<br>**230V**<br>**240V**<br>**380V**<br>**400V**<br>**415V**|**Rated Operational Current**<br>**500V**|**Contact**<br>**Configuration**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|||**Pkg.**<br>**Qty.**1|**Screw Terminal**<br>**Catalog Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|10<br>10|4<br>4|2<br>2|1.5<br>1.5|2NC<br>1NO-1NC|51<br>52<br>61<br>62<br>53<br>~~ii~~||||||61|||||5<br>5|**XTMCXFA02**<br>**XTMCXFA11**|
|||||||||||||||||||
||||||||||54||62|||||||
|||||||||||||||||||
|10|4|2|1.5|2NO||||63<br>53||||||||5|**XTMCXFA20**|
|||||||||||||||||||
|||||||||54<br>64||||||||||
|||||||||||||||||||
|10|4|2|1.5|4NC|||||51||61|71|||81|5|**XTMCXFA04**|
|10|4|2|1.5|1NO-3NC||52<br>62<br>72 82<br>53 61 71<br>81<br>82<br>72<br>62<br>54<br>~~FF~~||||||||||5|**XTMCXFA13**|
|10|4|2|1.5|2NO-2NC||54<br>53 61<br>62<br>71<br>72<br>~~FP~~|||||||||83<br>84|5|**XTMCXFA22**|
|10|4|2|1.5|3NO-1NC|||||53||61||73||83|5|**XTMCXFA31**|
|||||||||||||||||||
||||||||||54||62||74||84|||
|||||||||||||||||||
|10|4|2|1.5|4NO|||||53||63|73|||83|5|**XTMCXFA40**|
||||||||||54||64|74|||84|||
|||||||||||||||||||
|10|4|2|1.5|1NO-1NC<br>1NOE-1NCL||58<br>57 65<br>66<br>71<br>72<br>~~Ap~~|||||||||83<br>84|5|**XTMCXFAL22**2|
## _**Notes**_
1 Orders must be placed in multiples of package quantity listed.
- 2 One early-make contact (NOE), one late-break contact (NCL).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-6**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Front-Mount Auxiliary Contacts for Use with XTRE Control Relays**[1]
||||**Rated Operational Current AC-15 I**|**Rated Operational Current AC-15 Ie (A)**|**Rated Operational Current AC-15 Ie (A)**||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||**Conventional**<br>**Thermal Current,**||**220V**<br>**230V**|**380V**<br>**400V**||**Contact**|||||||**Pkg.**|**Screw Terminal**|
||**Ith (A), Open at 60°C**|**Poles**|**240V**|**415V**|**500V**|**Configuration**|**Circuit Symbol**||||||**Qty.**2|**Catalog Number**|
||||||||||||||||
|**Two-Pole**|16|2|6|3|1.5|2NO|63<br>53||||||5|**XTCEXFAC20**|
||||||||54<br>64||||||||
||||||||||||||||
||16|2|6|3|1.5|1NO-1NC|5361||||||5|**XTCEXFAC11**3|
||||||||||||||||
||||||||54<br>62||||||||
||||||||||||||||
||16|2|6|3|1.5|2NC|51<br>61||||||5|**XTCEXFAC02**|
||||||||||||||||
||||||||52<br>62||||||||
|**Four-Pole**|16<br>16|2<br>4|6<br>6|3<br>3|1.5<br>1.5|1NOE-1NCL<br>4NO|58<br>57 65<br>66<br>54<br>6373<br>6474<br>53<br>~~+}~~<br>~~+H~~||83<br>84||||5<br>5|**XTCEXFALC11**4<br>**XTCEXFAC40**3|
||||||||||||||||
||16|4|6|3|1.5|3NO-1NC|53 61<br>73|||||83|5|**XTCEXFAC31**3|
||||||||||||||||
||||||||||||||||
||||||||54<br>62<br>74|||||84|||
||||||||||||||||
|||16|4|6|3|1.5|2NO-2NC|54<br>5361<br>62<br>71<br>72<br>~~+H~~|||||83<br>84|5|**XTCEXFAC22**3|
||16|4|6|3|1.5|1NO-3NC|536171 81<br>82<br>72<br>62<br>54<br>~~HH~~||||||5|**XTCEXFAC13**|
||16|4|6|3|1.5|4NC|51<br>52<br>61<br>62<br>71<br>72 82<br>81<br>~~+H~~||||||5|**XTCEXFAC04**|
||16|4|6|3|1.5|1NO-1NC<br>1NOE-1NCL|58<br>5765<br>66<br>71<br>72<br>~~+H~~|||||83<br>84|5|**XTCEXFCLC22**4|
## _**Notes**_
1 Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NOE and NCL contacts) and between the auxiliary contacts and built-in contacts of the XTRE control relays.
- 2 Orders must be placed in multiples of package quantity listed.
- 3 Catalog number is shown with screw type terminal. For spring cage, add a “ **C** ” before the last 2 digits. For example, to order a spring cage version of the XTCEXFAC22, change the catalog number to XTCEXFAC **C** 22.
- 4 One early-make contact (NOE), one late-break contact (NCL).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-7**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## _**Suppressors**_
For AC operated contactors 50–60 Hz. On DC operated contactor relays and on XTRE10B, the suppressor circuit is built-in. Note dropout delay.
## _**Varistor Suppressor**_ 12
|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|**Varistor Suppressor for XTRE**<br>**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>24–48<br>XTRE(C)10B<br>10<br>**XTCEXVSBW**<br>48–130<br>10<br>**XTCEXVSBA**<br>130–240<br>10<br>**XTCEXVSBB**<br>**XTCEXVSB_**<br>A1<br>A2<br>~~——~~<br>~~oe~~<br>r~~r~~<br>~~4~~|
|---|---|---|---|---|---|---|---|---|
|||240–500|||||10|**XTCEXVSBC**|
|**XTMCXVS_**||**Varistor Suppressor for XTRM**|||||||
|**Voltage**<br>**For Use**<br>**with…**<br>24–48<br>XTRM6A_,<br>XTRM9A_<br>48–130<br>XTRM6A_,<br>XTRM9A_<br>**XTRM Relay with**<br>**Installed Suppressor**<br><>|||**Circuit Symbol**<br>A1<br>A2<br>;<br>~~oe ~~<br>~~4~~||||**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>10<br>**XTMCXVSW**<br>10<br>**XTMCXVSA**<br> ~~a~~||
|||110–250<br>XTRM6A_,<br>XTRM9A_|||||10|**XTMCXVSB**|
|||380–415<br>XTRM6A_,|||||10|**XTMCXVSN**|
|||XTRM9A_|||||||
## _**Varistor Suppressor with Integrated LED**_ 12
## **XTCEXVSLB_**
## **Varistor Suppressor for XTRE**
||**For Use**|||||||||||**Pkg.**||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Voltage**|**with…**|**Contact Sequence**||||||||||**Qty.**3|**Catalog Number**|
|24–48|XTRE(C)10B|||||||||||10|**XTCEXVSLBW**|
|130–240||A1||||||||||10|**XTCEXVSLBB**|
|||A2||||||||||||
_**RC Suppressor**_ 12
## **RC Suppressor for XTRE**
|**RC Suppressor for XTRE**||||||
|---|---|---|---|---|---|
|**RC Suppressor for XTRE**<br>**XTCEXRSB_**||||||
|**Voltage**<br>**For Use**<br>**with…**<br>**Contact Sequence**<br>24–48<br>XTRE(C)10B<br>48–130<br>110–240<br>240–500<br>A1<br>A2<br>¢~~-_a.~~<br>~~4~~||||**Pkg.**<br>**Qty.**3<br>10<br>10<br>10<br>10|**Catalog Number**<br>**XTCEXRSBW**<br>**XTCEXRSBA**<br>**XTCEXRSBB**<br>**XTCEXRSBC**|
## _**Notes**_
- 1 Note dropout delay.
- 2 For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor.
- 3 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-8**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**RC Suppressor**_[12]
**==> picture [341 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTMCXRS_ RC Suppressor for XTRM [3]<br>For Use Circuit Pkg.<br>Voltage with… Symbol Qty. [4] Catalog Number<br>24–48 XTRM6A_, A1 10 XTMCXRSW<br>< XTRM9A_ y!<br>Ca iy}<br>XTRM Relay with Installed Suppressor a 48–130 XTRM6A_, A2 | 10 XTMCXRSA<br>XTRM9A_<br>110–250 XTRM6A_, 10 XTMCXRSB<br>t acl XTRM9A_<br>**----- End of picture text -----**<br>
## _**Free-Wheel Diode Suppressor**_
In addition to the built-in suppressor circuit for DC actuated contactors. Prevents negative breaking voltage when contactors are used in combination with a safety PLC.
**XTCEXVSLBB Free-Wheel Diode Suppressor for XTRE For Use Pkg. Voltage with… Qty.**[4] **Catalog Number** 130–240 XTRE10B 10 **XTCEXVSLBB**
## _**Connector**_[5]
## _**Mechanical Interlock**_ 6
**==> picture [490 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connector Mechanical Interlock<br>For Use Pkg. For Use Pkg.<br>with… Qty. [4] Catalog Number with… Qty. [4] Catalog Number<br>XTCEXCNC XTRE(C)10B 50 XTCEXCNC XTCEXMLB XTRE10B_ 5 XTCEXMLB<br>i<br>— a<br>XTMCXCN XTRM10A 50 XTMCXCN “ir<br>XTMCXML XTRM10A_ 5 XTMCXML<br>**----- End of picture text -----**<br>
## _**Notes**_
- 1 Note dropout delay.
- 2 For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor.
- 3 For AC operated contactors, 50/60 Hz. Note dropout delay.
- 4 Orders must be placed in multiples of package quantity listed.
- 5 For mechanically arranging contactors in combinations. Distance between contactors is 0 mm.
- 6 For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted. For Frame B, mechanical lifespan is 2.5 x 10[6] operations and the distance between contactors is 0 mm.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-9**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**Electronic Timer Modules**_
Front- (top-) mounted timer modules for use with XTRE10B control relays. Can not be combined with top-mount auxiliary contacts, XTCEXF_.
## **XTCEXT_**
## **Electronic Timer Modules for XTRE**
|||||||||||**For Use**|**Pkg.**||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Voltage**<br>**Contact Sequence**<br>**On-Delay**|||||||||**Timing Range**|**with…**|**Qty.**1|**Catalog Number**|
||24 Vac/Vdc<br>100–130 Vac<br>200–240 Vac||||57<br>58<br>65<br>66<br>A1<br>A2<br>~~a~~||||0.05–1s<br>0.5–10s<br>15–100s|XTRE10B_|1|**XTCEXTEEC11T**<br>**XTCEXTEEC11A**<br>**XTCEXTEEC11B**<br>~~—~~|
||**Off-Delay**||||||||||||
|24 Vac/Vdc<br>100–130 Vac<br>200–240 Vac<br>24 Vac/Vdc<br>57<br>58<br>65<br>66<br>A1<br>A2<br>~~rats~~|||||||||0.05–1s<br>0.5–10s|XTRE10B_<br>XTRE10B_|1<br>1|**XTCEXTED1C11T**<br>**XTCEXTED1C11A**<br>**XTCEXTED1C11B**<br>**XTCEXTED10C11T**<br>~~—_—~~|
||100–130 Vac|||100–130 Vac||||||||**XTCEXTED10C11A**|
||200–240 Vac|||200–240 Vac||||||||**XTCEXTED10C11B**|
||24 Vac/Vdc||||||||5–100s|XTRE10B_|1|**XTCEXTED100C11T**|
||100–130 Vac<br>200–240 Vac|||100–130 Vac<br>200–240 Vac||||||||**XTCEXTED100C11A**<br>**XTCEXTED100C11B**|
||**Star-Delta**||||||||||||
||24 Vac/Vdc||||57<br>A1||67||1–30s|XTRE10B_|1|**XTCEXTEYC20T**|
|100–130 Vac<br>200–240 Vac<br>58<br>68<br>A2<br>~~aT~~||||||||||||**XTCEXTEYC20A**<br>**XTCEXTEYC20B**<br>~~—_~~|
|**Sealable Shroud**<br>Transparent sealable shroud used to protect||||||||||XTCEXTEE,|1|**XTCEXTESHRD**|
|||||electronic timer modules from unwanted access.||||||XTCEXTED,|||
|||||||||||XTCEXTEY|||
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-10**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Mini Electronic Timers**_
## **XTMT6A_**
## **Mini Electronic On-Delay Timers**
|**XTMT6A_**|**Mini Electronic On-Delay Timers**|**Mini Electronic On-Delay Timers**|**Mini Electronic On-Delay Timers**|||||||
|---|---|---|---|---|---|---|---|---|---|
||**Conventional**<br>**Thermal Current**<br>**Ie (A)**<br>~~a~~|**Rated Operational Current**<br>**Ie AC-11 Amps**<br>**220/230/240V**<br>~~a~~|**Rated Operational Current**<br>**380/400/440V**<br>~~a~~|**Time**<br>**Range**<br>~~a~~|**Function**<br>~~a~~|**Terminal Marking**<br>**According to**<br>**EN 50042**<br>~~a~~|||**Catalog Number**<br>~~a~~|
||6<br>6|3<br>3|3<br>6|1.5–30 sec<br>0.05–1 sec<br>0.15–3 sec<br>0.5–10 sec<br>3–60 sec|Fixed, on-delay<br>Fixed, on-delay|**XTMT6A30S11B**<br>**XTMT6A60H11B**<br>A1<br>A2<br>15<br>16 18||||
|||||0.15–3 min<br>0.5–10 min||||||
|||||3–60 min||||||
|0.15–3h<br>0.5–10h<br>3–60h<br>6<br>3<br>3<br>0.05–1 sec<br>0.15–3 sec<br>0.5–10 sec<br>3–60 sec<br>0.15–3 min<br>0.5–10 min<br>3–60 min<br>Adjustable:<br>on-delay;<br>fleeting contact<br>on energization;<br>flashing; pulse<br>generating;<br>ON-OFF<br>**XTMT6A60H70B**<br>A1<br>A2<br>Z2<br>Z1<br>15<br>16 18<br>aan<br>1 02,0)~~a~~<br>~~sy”~~||||||||||
|||||0.15–3h<br>0.5–10h||||||
|||||3–60h||||||
## _**Electronic Star-Delta (Wye-Delta) Timers**_
## **XTTR6A60S51**
## **Electronic Star-Delta (Wye-Delta) Timers**
|**Conventional**<br>**Thermal Current**|**Rated Operational Current**<br>**Ie AC-11 Amps**|**Rated Operational Current**|**Time**||**Terminal Marking**<br>**According to**|**Terminal Marking**<br>**According to**|||
|---|---|---|---|---|---|---|---|---|
|**Ie (A)**|**230V**|**400V**|**Range**|**Function**|**EN 50042**|||**Catalog Number**|
|6|3|3|3–60 sec|Fixed, star-delta|17|||**XTTR6A60S51B**|
||||||A1<br>A2<br>18<br>28<br>~~=e~~||||
## **Actuating Voltage**
24–240 50/60 Hz 24–240 Vdc
**Admissible Cable Length Connection to** Cable unscreened, with cable cross-section 0.5–1.5 mm[2] Y1/Y2, Z1/Z2 Two-core cable M250 Two-core cable in the same cable duct with the main cable, 50/60 Hz M50
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-11**
1.1
_**XT**_ IEC Power Control
**1**
## IEC Contactors and Starters
## **Technical Data and Specifications**
## **Relays and Timers**
|**Relays and Timers**||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Description**|**XTRE**||||||**XTCEXFAC_**||||||**XTCEXTE_**|**XTRM**|**XTMCXFA_**|
|**General**||||||||||||||||
|Standards|IEC/EN 60947,||||||IEC/EN 60947,||||||DIN EN 61812,|IEC/EN 60947,|IEC/EN 60947,|
||VDE 0660,<br>UL, CSA||||||VDE 0660,<br>UL, CSA||||||IEC/EN 60947,<br>VDE 060, UL, CSA|VDE 0660,<br>UL, CSA|VDE 0660,<br>UL, CSA|
|Lifespan, mechanical—operations||||||||||||||||
|AC operated|20,000,000||||||10,000,000||||||3,000,000|10,000,000|10,000,000|
|DC operated|20,000,000||||||10,000,000||||||3,000,000|20,000,000|20,000,000|
|Maximum operating frequency (ops/hr)<br>Climatic proofing|9000<br>1||||||9000<br>1||||||—<br>1|9000<br>1|9000<br>1|
|Ambient temperature||||||||||||||||
|Open (°C, min./max.)|–25/60||||||–25/60||||||–40/80|–25/50|–25/50|
|Enclosed (°C, min./max.)|–25/40||||||–25/40||||||–25–60|–25/40|–25/40|
|Ambient temperature for storage (°C, min./max.)<br>Mounting position|–40/80<br>90°|||||90°|–40/80<br>90°||30°||||–25–40<br>As required,<br>not suspended|—<br>As required, except<br>vertically A1/A2 at<br>the bottom|—<br>As required, except<br>vertically A1/A2 at<br>the bottom|
||180°|||||||||||||||
|||||||||||||||||
|Mechanical shock resistance (IEC/EN 60068-2-27)||||||||||||||||
|Half-sinusoidal shock 10 ms<br>Base unit with auxiliary contact module||||||||||||||||
|Make contact|7g||||||7g||||||6g|10g|10g|
|Break contact|5g||||||5g||||||6g|8g|8g|
|Degree of protection|IP20||||||IP20||||||IP20|IP20|IP20|
|Protection against direct contact from the front|Finger and||||||Finger and||||||Finger and|Finger and|Finger and|
|when actuated by a perpendicular test finger (IEC 536)|back-of-hand proof||||||back-of-hand|proof|||||back-of-hand proof|back-of-hand proof|back-of-hand proof|
|Weight||||||||||||||||
|AC operated (kg)|0.23||||||0.05||||||0.08|0.17|—|
|DC operated (kg)<br>Terminal capacity|0.28||||||0.05||||||0.08|0.20|—|
|Screw terminals||||||||||||||||
|Solid (mm2)|1 x (0.75–4)0.||||||1 x (0.75–4)0.||||||1 x (0.75–2.5)|1 x (0.75–2.5)|1 x (0.75–2.5)|
|Flexible with ferrule (mm2)|2 x (0.75–2.5)<br>1 x (0.75–2.5)||||||2 x (0.75–2.5)<br>1 x (0.75–2.5)||||||2 x (0.75–1.5)<br>1 x (0.75–1.5)|2 x (0.75–2.5)<br>1 x (0.75–1.5)|2 x (0.75–2.5)<br>1 x (0.75–1.5)|
|Solid or stranded (AWG)|2 x (0.75–2.5)<br>18–14||||||2 x (0.75–2.5)||||||2 x (0.75–1.5)<br>18–14|2 x (0.75–1.5)<br>18–14|2 x (0.75–1.5)|
|Terminal screw|M3.5||||||M3.5||||||M3.5|M3.5|M3.5|
|Pozidriv screwdriver|Size 2||||||Size 2||||||Size 2|Size 2|Size 2|
|Standard screwdriver (mm)|0.8 x 5.5||||||0.8 x 5.5||||||0.8 x 5.5|0.8 x 5.5|0.8 x 5.5|
||1 x 6||||||1 x 6||||||1 x 6|1 x 6|1 x 6|
|Max. tightening torque (Nm)|1.2||||||1.2||||||1.2|1.2|1.2|
|Spring cage terminals||||||||||||||||
|Solid (mm2)|1 x (0.75–2.5)||||||1 x (0.75–2.5)||||||—|1 x (0.75–2.5)|1 x (0.75–2.5)|
||2 x (0.75–2.5)||||||2 x (0.75–2.5)||||||—|2 x (0.75–2.5)|2 x (0.75–2.5)|
|Flexible with or without ferrule DIN 46228 (mm2)|1 x (0.75–2.5)||||||1 x (0.75–2.5)||||||—|1 x (0.75–2.5)|1 x (0.75–2.5)|
||2 x (0.75–2.5)||||||2 x (0.75–2.5)||||||—|2 x (0.75–2.5)|2 x (0.75–2.5)|
|Solid or stranded (AWG)|18–14||||||18–14||||||—|18–14|18–14|
|Standard screwdriver (mm)|0.6 x 3.5||||||0.6 x 3.5||||||—|0.6 x 3.5|0.6 x 3.5|
_**Note**_
> 1 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-12**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Relays and Timers, continued**
|**Relays and Timers, continued**||||||
|---|---|---|---|---|---|
|**Description**|**XTRE**|**XTCEXFAC_**|**XTCEXTE_**|**XTRM**|**XTMCXFA_**|
|**Contacts**||||||
|Interlocked opposing contacts to ZH 1/457,|Yes|Yes|No|Yes|Yes|
|including auxiliary contact module||||||
|Rated impulse withstand voltage (Uimp) Vac|6000|6000|6000|6000|6000|
|Overvoltage category/pollution degree|III/3|III/3|III/3|III/3|III/3|
|Rated insulation voltage (Ui) Vac<br>Rated operational voltage (Ue) Vac|690<br>690|690<br>500|600<br>400|690<br>600|690<br>600|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1<br>Between coil and auxiliary contacts (Vac)|400|400|250|300|300|
|Between the auxiliary contacts (Vac)|400|400|250|300|300|
|Rated operational current||||||
|AC-15 220/240V Ie|6|6|Please inquire|6|4|
|380/415V Ie<br>500V Ie|4<br>1.5|3<br>—|Please inquire<br>—|3<br>1.5|2<br>1.5|
|DC-131||||||
|DC13 L/R <<br>~~1~~5 ms||||||
|Contacts in series—voltage:||||||
|1—24V|10|10|—|2.5|2.5|
|1—60V|6|6|—|—|—|
|2—60V<br>1—110V|10<br>3|10<br>3|—<br>—|2.5<br>—|2.5<br>—|
|3—110V|6|6|—|1.5|1.5|
|1—220V|1|1|—|—|—|
|3—220V|5|5|—|0.5|0.5|
|DC13 L/R <<br>~~5~~0 ms||||||
|Contacts in series—voltage:||||||
|3—24V|4|—|—|—|—|
|3—60V|4|—|—|—|—|
|3—110V|2|—|—|—|—|
|3—220V|1|—|—|—|—|
|Control circuit reliability|Failure rate = <10–8, <1 failure||—|Failure rate = <10–8, <1 failure||
|(at Ue= 24 Vdc, Umin= 17, Imin= 5.4 mA)|in 100 million operations|||in 100 million operations||
|Conventional thermal current (Ith)|16|16|6|10|10|
|Short-circuit rating without welding<br>Maximum overcurrent protective device||||||
|220/240V–XTPR Frame B|4|—|—|4|4|
|380/415V–XTPR Frame B|4|—|—|4|4|
|Short-circuit protection, max. fuse||||||
|500V (A gG/gL)|10|10|6|6|6|
|500V (A fast)|—|—|—|10|10|
|Current heat losses at load of Ith<br>AC operated (W)|0.3|0.3|—|0.2|0.2|
|DC operated (W)|0.3|0.3|—|0.3|0.3|
## _**Note**_
> 1 Making and breaking conditions to DC13, time constant as stated.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-13**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Relays and Timers, continued**
|**Relays and Timers, continued**||||||
|---|---|---|---|---|---|
|**Description**|**XTRE**|**XTCEXFAC_**|**XTCEXTE_**|**XTRM**|**XTMCXFA_**|
|**Magnet Systems**||||||
|Pickup and dropout values||||||
|AC operated||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz,<br>60 Hz (pickup x Uc)|0.8–1.1|—|0.85–11|0.8–1.1|—|
|Dual-frequency coil 50/60 Hz (pickup x Uc)<br>DC operated1|0.8–1.1|—|—|0.85–1.1|—|
|Pickup voltage (pickup x Uc)<br>At 24V: without auxiliary contact module (40°C) (pickup x Uc)|0.8–1.1<br>0.7–1.3|—<br>—|0.7–1.2<br>—|0.85–1.3<br>0.7–1.3|—<br>—|
|Power consumption||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz||||||
|Pickup VA|24|—|—|25|—|
|Pickup W<br>Sealing VA|19<br>3.4|—<br>—|—<br>2|22<br>4.6|—<br>—|
|Sealing W|1.2|—|1.8|1.3|—|
|Dual-frequency coil 50/60 Hz at 50 Hz||||||
|Pickup VA|27|—|—|30|—|
|Pickup W|22|—|—|26|—|
|Sealing VA|4.2|—|—|5.4|—|
|Sealing W<br>Dual-frequency coil 50/60 Hz at 60 Hz|1.4|—|—|1.6|—|
|Pickup VA|25|—|—|29|—|
|Pickup W|21|—|—|24|—|
|Sealing VA|3.3|—|—|3.9|—|
|Sealing W<br>DC operated|1.2|—|—|1.2|—|
|Pull-in = sealing (W)<br>Duty factor (% DF)|3<br>100|—<br>—|—<br>100|2.6<br>100|—<br>—|
|Switching times at 100% Uc(approximate values)||||||
|AC operated closing delay (ms)|<<br>~~2~~1|—|—|14–21|—|
|AC operated NO contact opening delay (ms)|<<br>~~1~~8|—|—|8–18|—|
|AC operated with auxiliary contact module,<br>max. closing delay (ms)|—|—|—|45|45|
|DC operated closing delay (ms)|<<br>~~3~~1|—|—|26–35|—|
|DC operated NO contact opening delay (ms)|<<br>~~1~~2|—|—|15–25|—|
|DC operated with auxiliary contact module,<br>max. closing delay (ms)|—|—|—|70|70|
## _**Note**_
> 1 Smoothed DC or three-phase bridge rectifier.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-14**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Control Relays—Characteristic Curves**_
## **XTRE (AC-15)**
## **XTRE (DC-13)**[1]
**==> picture [445 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
Component lifespan (operations) Component lifespan (operations)<br>Ie = Rated operational current Ie = Rated operational current<br> 10 [6] 10 [6]<br>20 20<br>10 10<br>5 5<br>2 2<br>1 1<br>DC-13<br>0.5 0.5<br>24 V<br>AC-15<br>0.2 0.2 L<br>240 V = 50 ms<br>R<br>0.1 0.1<br>0.01 0.02 0.05 0.1 2.0 0.5 1 2 5 10 A 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 A<br>Ie Ie<br>**----- End of picture text -----**<br>
The diagrams show the closing and opening travel of the contact of the contactor relays and auxiliary contacts at no load. Tolerances are not taken into consideration.
## _**Contact Travel Diagrams**_
## **XTRE**
XTRE_ — AC Operation Normally open contact Normally closed contact
XTCEXFAC_ — AC Operation Normally open contact Normally closed contact
XTCEXFALC_ — AC Operation Normally open contact (early make) Normally closed contact (late make)
**==> picture [65 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
0 3.3 4.5<br>0 1.0 4.5<br>0 3.2 4.5<br>0 1.6 4.5<br>0 2.0 4.5<br>0 2.8 4.5<br>**----- End of picture text -----**<br>
XTRE — DC Operation Normally open contact Normally closed contact XTCEXFAC_ — DC Operation Normally open contact Normally closed contact
XTCEXFALC_ — DC Operation Normally open contact (early make) Normally closed contact (late make)
**==> picture [64 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
0 2.1 2.9<br>0 0.7 2.9<br>0 2.3 2.9<br>0 0.7 2.9<br>0 1.1 2.9<br>0 1.9 2.9<br>**----- End of picture text -----**<br>
## _**Note**_
> 1 Making and breaking conditions to DC-13, time constant as stated.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-15**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Flow Diagrams—Electronic Timers, XTMT Mini Timers**_
## **On-Delay**
**==> picture [21 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1-A2<br>15-18<br>LED<br>**----- End of picture text -----**<br>
**==> picture [4 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
t<br>**----- End of picture text -----**<br>
## **ON-OFF Function**
**==> picture [109 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1-A2<br>15-18<br>OFF ON OFF<br> LED<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in mm [in.]
## _**Mini Contactor Relays**_
## **Mini Control Relay XTRM**
**==> picture [122 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.5 [.22]<br>58<br>[2.28]<br>45<br>[1.77] 52 – 54<br>[2.05] – [2.13]<br>**----- End of picture text -----**<br>
## **Fleeting Contact on Energization**
**==> picture [107 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1-A2<br>15-18<br>t<br>LED<br>**----- End of picture text -----**<br>
## **Flashing, Pulse Initiating**
**==> picture [108 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1-A2<br>15-18<br>t t t t<br>LED<br>**----- End of picture text -----**<br>
## **XTRM Mini Control Relay with IP40 XTMCX Shroud**
**==> picture [149 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
43<br>[1.69]<br>58 45<br>[2.28] [1.77]<br>45 65.3<br>[1.77] [2.57]<br>**----- End of picture text -----**<br>
## **XTRM Mini Control Relay with RC or Varistor Suppressor**
## **Pulse Generating**
**==> picture [108 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1-A2<br>15-18<br>t 0.5 s<br>LED<br>**----- End of picture text -----**<br>
**==> picture [126 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
62.5<br>[2.46]<br>45<br>[1.77] 52 – 54<br>[2.05] – [2.13]<br>**----- End of picture text -----**<br>
## _**Star-Delta (Wye-Delta) Timer**_
## **XTRM Mini Control Relay with XTMCXFA Auxiliary Contact**
## **Star-Delta**
**==> picture [124 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1-A2<br>17-18<br>17-28<br>t tu<br>Power LED<br>LED<br>LED<br>**----- End of picture text -----**<br>
**==> picture [211 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
M4<br>58 50<br>[2.28] [1.97]<br>45 83 – 86 35<br>[1.77] [3.27] – [3.39] [1.38]<br>**----- End of picture text -----**<br>
## _**Rating Data**_
## **Rating Data for Approved Types**
|**Pilot Duty**|**General Use**|
|---|---|
|**Control Relays—XTMR**||
|A600, P300|10A–600 Vac|
||0.5A–250 Vdc|
|**Timers—XTMT, XTTR**||
|B300|6A–250 Vac|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-16**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## Approximate Dimensions in mm [in.]
## _**Control Relays**_
## **Control Relay XTRE with XTCEXFA Auxiliary Contact**
**==> picture [234 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
68 45 18<br>[2.68] [1.77] [.71]<br>18<br>6.5<br>[.71]<br>[.26]<br>45 75<br>[1.77] [2.95]<br>117<br>[4.61]<br>**----- End of picture text -----**<br>
## **Control Relay with Spring Cage Terminals XTREC with XTCEXFA Auxiliary Contact**
**==> picture [222 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
68 52.3 26.4<br>[2.68] [2.06] [1.04]<br>36 6.5<br>[1.42] [.26]<br>45 75<br>[1.77] [2.95] 125<br>[4.92]<br>**----- End of picture text -----**<br>
## **Control Relay XTRE with XTCEXMLB Mechanical Interlock**
**==> picture [213 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
68 45<br>[2.68] [1.77]<br>6.5<br>90 [.26]<br>[3.54]<br>75<br>[2.95]<br>**----- End of picture text -----**<br>
## **Coil Suppressors for Use with XTRE Control Relays**
**==> picture [139 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
28 Approx.<br>[1.10] 32 [1.26]<br>25.9<br>[1.02]<br>19.2 9<br>[.76] [.35]<br>25<br>[.98]<br>**----- End of picture text -----**<br>
## **Electronic Timer Module XTCEXTE**
**==> picture [199 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
38 25<br>[1.50] [.98]<br>45 70<br>[1.77] [2.76]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-17**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTMC Miniature Contactor**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|
|Miniature Controls||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-19**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-20**|
|Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-24**|
|Technical Data and Specifications . . . . . . . . . . .<br>Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .<br>Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>An Eaton<br>Green Solution<br>a|**V5-T1-27**<br>**V5-T1-32**<br>**V5-T1-34**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .|**V5-T1-217**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . .|**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## **Miniature Controls**
## **Product Description**
Eaton’s new line of _**XT**_ miniature controls includes non-reversing and reversing mini contactors, mini overload relays and snap-on accessories. A wide range of applications is possible, including small electrical motors from fractional to 5 hp (460 Vac) or up to 4 kW (400 Vac).
## **Application Description**
Due to its compact size, the _**XT**_ line of mini controls is best suited to be applied in light-duty loads, such as hoisting, packaging, material handling, heating, lighting and automation systems. _**XT**_ mini contactors are a particularly compact, economic and environmentally friendly solution wherever control of small motors or loads is required.
## **Features**
## _**Mini Contactors—Types XTMC and XTMF, 6–9A**_
- AC control from 12V to 550V 50 Hz, 600V 60 Hz
- DC control from 12V to 220V
- Reversing or non-reversing
- Three- and four-pole configurations
- Three-pole XTMC
- Four-pole XTMF
- Panel or DIN rail mounting
- IP20 finger and back-ofhand proof
- Low noise operation
- High degree of climatic proofing
- Large ambient temperature range –25° to 50°C [–13° to 122°F]
## _**Mini Overload Relays— Bimetallic Type XTOM**_
- Phase failure sensitivity
- Direct mount to XTMC and XTMF mini contactors
- Trip Class 10
- 11 settings to cover 0.1 to 12A
- Ambient temperature compensated –5° to 50°C [23° to 122°F]
- Manual and automatic reset by selector switch
- One make (NO) or one break (NC) auxiliary contact as standard
- Test/Off button
- Trip-free release
## **Standards and Certifications**
- IEC EN 60947
- CE approved
- UL
- CSA
- CCC
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-18**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Instructional Leaflets**_
Pub51219 XTMC, XTMF Mini Contactors, XTRM Mini Control Relay and Accessories Pub51243 XTOM Mini Overload Relays Pub51206 Mini Reversing Link Kits MN03402002E XTOM Mini Overload Relays Installation and User Manual
## **Catalog Number Selection**
## _**XT**_ **IEC Miniature Contactors**
**==> picture [481 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT MC 6 A 10 A<br>Designation Coil Codes<br>XT = XT IEC power control Type A = 110V 50 Hz, 120V 60 Hz L = 380V 50 Hz, 440V 60 Hz<br>MC = Three-pole FVNR Current Rating, B = 220V 50 Hz, 240V 60 Hz N = 400V 50 Hz<br>mini IEC contactor AC-3 F = 230V 50 Hz P = 380V 60 Hz<br>MF = Four-pole FVNR mini XTMC T = 24V 50/60 Hz R = 12V 50/60 Hz<br>IEC contactor 6 = 6.6A TD = 24 Vdc W = 42V 50 Hz, 48V 60 Hz<br>MR = Three-pole FVR mini 9 = 8.8A C = 415V 50 Hz, 480V 60 Hz Y = 48V 50 Hz<br>IEC contactor XTMF D = 550V 50 Hz, 600V 60 Hz AD = 120 Vdc<br>E = 208V 60 Hz BD = 220 Vdc<br>9 = 8.8A<br>G = 190V 50 Hz, 220V 60 Hz RD = 12 Vdc<br>H = 240V 50 Hz, 277V 60 Hz WD = 48 Vdc<br>Frame Size<br>A = 45 mm mini Integral Auxiliary Contact<br>01 = 1NC<br>10 = 1NO<br>**----- End of picture text -----**<br>
_**XT**_ **IEC Miniature Overload Relays**
**==> picture [482 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT OM P16 A C1<br>Designation Trip Class<br>XT = XT IEC power control Type Frame Size C1 = Class 10A<br>OM = Mini overload relay Overload Release A = 45 mm mini<br>P16 = 0.1–0.16A 2P4 = 1.6–2.4A<br>P24 = 0.16–0.24A 004 = 2.4–4A<br>P40 = 0.24–0.4A 006 = 4–6A<br>P60 = 0.4–0.6A 009 = 6–9A<br>001 = 0.6–1A 012 = 9–12A<br>1P6 = 1–1.6A<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-19**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Product Selection**
## _**Full Voltage Non-Reversing Miniature Contactors**_
## **Maximum UL Ratings—Single-Phase and Three-Phase**
|**XTMC_**|**Maximum UL Ratings—Single-Phase and Three-Phase**|**Maximum UL Ratings—Single-Phase and Three-Phase**|**Maximum UL Ratings—Single-Phase and Three-Phase**|**Maximum UL Ratings—Single-Phase and Three-Phase**|**Maximum UL Ratings—Single-Phase and Three-Phase**|**Maximum UL Ratings—Single-Phase and Three-Phase**|**Maximum UL Ratings—Single-Phase and Three-Phase**||||
|---|---|---|---|---|---|---|---|---|---|---|
||**Horsepower Ratings**|**Horsepower Ratings**|||||||||
||**Single-Phase**|||**Three-Phase**||||**Number of**|**Auxiliary**|**Screw Terminal**|
||**115V**|**200V**|**230V**|**200V**|**230V**|**460V**|**575V**|**Power Poles**|**Contacts**|**Catalog Number**1|
||1/4|3/4|1|1-1/2|2|3|3|3|1NO|**XTMC6A10_**|
||1/4|3/4|1|1-1/2|2|3|3|3|1NC|**XTMC6A01_**|
||1/2<br>1/2|1<br>1|1-1/2<br>1-1/2|2<br>2|3<br>3|5<br>5|5<br>5|3<br>3|1NO<br>1NC|**XTMC9A10_**<br>**XTMC9A01_**|
||1/2|1|1-1/2|2|3|5|5|4|—|**XTMF9A00_**|
## **Maximum IEC Ratings AC-3**
|**Operational Current**<br>**AC-3 Amp Rating**|**Conventional Free**<br>**Air Thermal Current**|**Three-Phase Motors 50–60 Hz**<br>**220–**<br>**380–**|**Three-Phase Motors 50–60 Hz**<br>**220–**<br>**380–**|**Three-Phase Motors 50–60 Hz**|**660/**|**Number of**|**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|
|**380/400V**|**AC-1 at 50°C**|**240V**|**400V**|**550V**|**690V**|**Power Poles**|**Contacts**|**Catalog Number**1|
|6.6|20|1.5|3|3|3|3|1NO|**XTMC6A10_**|
|6.6<br>8.8|20<br>20|1.5<br>2.2|3<br>4|3<br>4|3<br>4|3<br>3|1NC<br>1NO|**XTMC6A01_**<br>**XTMC9A10_**|
|8.8|20|2.2|4|4|4|3|1NC|**XTMC9A01_**|
|8.8|20|2.2|4|4|4|4|—|**XTMF9A00_**|
## **Magnet Coil Suffix**
|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|
|---|---|---|---|---|---|---|---|
|110V 50 Hz, 120V 60 Hz<br>220V 50 Hz, 240V 60 Hz|**A**<br>**B**|415V 50 Hz, 480V 60 Hz<br>550V 50 Hz, 600V 60 Hz|**C**<br>**D**3|380V 60 Hz<br>12V 50/60 Hz|**P**<br>**R**3|120 Vdc<br>220 Vdc|**AD**<br>**BD**|
|230V 50 Hz|**F**|208V 60 Hz|**E**|42V 50 Hz, 48V 60 Hz|**W**|12 Vdc|**RD**|
|24V 50/60 Hz|**T**|190V 50 Hz, 220V 60 Hz|**G**|48V 50 Hz|**Y**|48 Vdc|**WD**|
|24 Vdc|**TD**2|240V 50 Hz, 277V 60 Hz|**H**|—|—|—|—|
|—|—|380V 50 Hz, 440V 60 Hz|**L**|—|—|—|—|
## _**Notes**_
IEC Utilization Categories, see **Page V5-T1-247** .
AC-1: Non-inductive or slightly inductive loads.
AC-3: Squirrel cage motors—starting, switching of motors during running.
AC-4: Squirrel cage motors—starting, plugging, inching.
> 1 Underscore (_) indicates magnetic coil suffix required.
> 2 With DC operation: Integrated diode resistor combination, coil rating 2.6W.
- 3 XTMF four-pole contactor not available with “D” or “R” coil voltage suffix.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-20**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Full Voltage Reversing Miniature Contactors**_
## **XTMR_**
## **Maximum UL Ratings—Single-Phase and Three-Phase**
|**Horsepower Ratings**|**Horsepower Ratings**||||||||
|---|---|---|---|---|---|---|---|---|
|**Single-Phase**<br>**115V**|**200V**|**230V**|**Three-Phase**<br>**200V**|**230V**|**460V**|**575V**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Catalog Number**12|
|1/4|3/4|1|1-1/2|2|3|3|63<br>63|**XTMR6A21_**|
|1/2|1|1-1/2|2|3|5|5|64<br>64<br>64<br>63<br>64<br>63<br>~~{4~~|**XTMR9A21_**|
## **Maximum IEC Ratings AC-3**
|||**Three-Phase Motors 50–60 Hz**|**Three-Phase Motors 50–60 Hz**|**Three-Phase Motors 50–60 Hz**||||
|---|---|---|---|---|---|---|---|
|**Operational Current**<br>**AC-3 Amp Rating**|**Conventional Free**<br>**Air Thermal Current**|**220/**<br>**230/**|**380/**<br>**400/**||**660/**|**Spare Auxiliary Contacts**||
|**380/400V**<br>6.6|**AC-1 at 50°C**<br>20|**240V**<br>1.5|**440V**<br>3|**500V**<br>3|**690V**<br>3|**K1M**<br>**K2M**<br>64<br>63<br>64<br>63<br>~~{4~~|**Catalog Number**12<br>**XTMR6A21_**|
|8.8|20|2.2|4|4|4|64<br>63<br>64<br>63<br>~~{4~~|**XTMR9A21_**|
## **Magnet Coil Suffix**
|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|
|---|---|---|---|---|---|---|---|
|110V 50 Hz, 120V 60 Hz|**A**|415V 50 Hz, 480V 60 Hz|**C**|380V 60 Hz|**P**|120 Vdc|**AD**|
|220V 50 Hz, 240V 60 Hz|**B**|550V 50 Hz, 600V 60 Hz|**D**3|12V 50/60 Hz|**R**3|220 Vdc|**BD**|
|230V 50 Hz|**F**|208V 60 Hz|**E**|42V 50 Hz, 48V 60 Hz|**W**|12 Vdc|**RD**|
|24V 50/60 Hz<br>24 Vdc|**T**<br>**TD**2|190V 50 Hz, 220V 60 Hz<br>240V 50 Hz, 277V 60 Hz|**G**<br>**H**|48V 50 Hz<br>—|**Y**<br>—|48 Vdc<br>—|**WD**<br>—|
|—|—|380V 50 Hz, 440V 60 Hz|**L**|—|—|—|—|
## _**Notes**_
IEC Utilization Categories, see **Page V5-T1-247** . AC-1: Non-inductive or slightly inductive loads.
AC-3: Squirrel cage motors—starting, switching of motors during running.
AC-4: Squirrel cage motors—starting, plugging, inching.
- 1 Underscore (_) indicates magnetic coil suffix required. See Magnet Coil Suffix table above.
- 2 The factory-installed reversing mini contactor includes (2) XTMC…01 contactors, (2) XTMCXFA20 2NO front-mount auxiliary contacts
(1) XTMCXRL reversing link kit and (1) XTMCXML mechanical interlock.
- 3 XTMF four-pole contactor not available with “D” or “R” coil voltage suffix.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-21**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Star-Delta (Wye-Delta) Miniature Contactors**_
## **XTMC_**
**Maximum Current UL Ratings—Single-Phase and Three-Phase**[1]
|**Horsepower Ratings**<br>**Single-Phase**|**Horsepower Ratings**<br>**Single-Phase**|**Three-Phase**|**Three-Phase**|||**Maximum**<br>**Changeover**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Component**||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**115V**<br>**200V**<br>1/2<br>1|**230V**<br>1-1/2|**200V**<br>2|**230V**<br>3|**460V**<br>5|**575V**<br>7-1/2|**Time (sec.)**<br>30|**K1M**<br>21<br>22<br>31<br>32<br>~~#~~|||||53<br>54|**Description**<br>K1M main contactor<br>K1M auxiliary contact|**Catalog Number**2<br>**XTMC9A10_**<br>**XTMCXFC22**|
||||||||||||||K5M delta contactor|**XTMC9A01_**|
||||||||||||||K3M star contactor|**XTMC9A10_**|
||||||||||||||K3M auxiliary contact<br>K1T timing relay|**XTMCXFC02**<br>**XTTR6A60S51B**|
## **Maximum IEC Ratings AC-3**[1]
|**Horsepower Ratings**|**Horsepower Ratings**||**Maximum**|||||||
|---|---|---|---|---|---|---|---|---|---|
|**Three-Phase Motors 50–60 Hz**<br>**220/230/240V**|**Three-Phase Motors 50–60 Hz**<br>**380/400/440V**|**500V**|**Changeover**<br>**Time (sec.)**|**Spare Auxiliary Contacts**<br>**K1M**||||**Component**<br>**Description**|**Catalog Number**2|
|4|5.5|5.5|30||21|31|53|K1M main contactor|**XTMC9A10_**|
||||||22|32|54|K1M auxiliary contact<br>K5M delta contactor|**XTMCXFC22**<br>**XTMC9A01_**|
|||||||||K3M star contactor<br>K3M auxiliary contact|**XTMC9A10_**<br>**XTMCXFC02**|
|||||||||K1T timing relay|**XTTR6A60S51B**|
## **Mini Overload Relay Settings (A)**
|**Mini Overload Relay Settings (A)**||
|---|---|
|**Setting**|**Starting**|
|**A:**INx 0.58|<<br>~~1~~5 sec|
|Motor protection in the Y and delta configurations.||
|**B:**INx 1|15–40 sec|
|Only partial motor protection in star position||
|**C:**INx 0.58|>40 sec|
|Motor not protected in star position.||
|Timing relay set to approximately 10 sec.||
## _**Notes**_
Depending on the coordination type required (that is, Type 1 or Type 2) it must be established whether the fuse protection and the input wiring for the main and delta contactors are to be common or separate.
> 1 Operating frequency: 30 starts/hour. See Magnet Coil Suffix table on following page.
> 2 Underscore (_) indicates magnet coil suffix required.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-22**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Magnet Coil Suffix**
|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|
|---|---|---|---|---|---|---|---|
|110V 50 Hz, 120V 60 Hz|**A**|415V 50 Hz, 480V 60 Hz|**C**|400V 50 Hz|**N**|120 Vdc|**AD**|
|220V 50 Hz, 240V 60 Hz|**B**|550V 50 Hz, 600V 60 Hz|**D**|380V 60 Hz|**P**|220 Vdc|**BD**|
|230V 50 Hz|**F**|208V 60 Hz|**E**|12V 50/60 Hz|**R**|12 Vdc|**RD**|
|24V 50/60 Hz<br>24 Vdc|**T**<br>**TD**1|190V 50 Hz, 220V 60 Hz<br>240V 50 Hz, 277V 60 Hz|**G**<br>**H**|24V 50 Hz<br>42V 50 Hz, 48V 60 Hz|**U**<br>**W**|48 Vdc<br>—|**WD**<br>—|
|—|—|380V 50 Hz, 440V 60 Hz|**L**|48V 50 Hz|**Y**|—|—|
## _**Mini Overload Relays**_
## **XTOM_**
**Mini Overload Relays**[23]
||||||||||||||**Short-Circuit Protection (A)**<br>**Type 1**<br>**Type 2**|**Short-Circuit Protection (A)**<br>**Type 1**<br>**Type 2**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Overload**<br>**Release It**|**Trip**<br>**Class**|**Contact**<br>**Sequence**||||||||||**Contact**<br>**Configuration**|**Coordination,**<br>**gG/gL**|**Coordination,**<br>**gG/gL**|**Circuit**<br>**Breaker**|**CEC/NEC**<br>**Fuse**|**Catalog Number**|
|0.1–0.16A<br>10A<br>0.16–0.24A<br>10A<br>0.24–0.4A<br>10A<br>6<br>4<br>2<br>98 96<br>97 95<br>~~ee~~||||||||||||1NO-1NC<br>1NO-1NC<br>1NO-1NC|20<br>20<br>20|0.5<br>1<br>2|15<br>15<br>15|—<br>—<br>—|**XTOMP16AC1**<br>**XTOMP24AC1**<br>**XTOMP40AC1**|
|0.4–0.6A|10A|||||||||||1NO-1NC|20|2|15|—|**XTOMP60AC1**|
|0.6–1A|10A|||||||||||1NO-1NC|20|4|15|3|**XTOM001AC1**|
|1–1.6A|10A|||||||||||1NO-1NC|20|6|15|6|**XTOM1P6AC1**|
|1.6–2.4A|10A|||||||||||1NO-1NC|20|6|15|6|**XTOM2P4AC1**|
|2.4–4A<br>4–6A|10A<br>10A|||||||||||1NO-1NC<br>1NO-1NC|20<br>20||15<br>15|15<br>20|**XTOM004AC1**<br>**XTOM006AC1**|
|6–9A|10A|||||||||||1NO-1NC|20||15|35|**XTOM009AC1**|
|9–12A|10A|||||||||||1NO-1NC|—||—|45|**XTOM012AC1**|
## _**Notes**_
1 With DC operation: Integrated diode resistor combination, coil rating 2.6W.
- 2 Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. See MN03402002E for more information.
- 3 When fitted directly to the contactor, a clearance of at least 5 mm is required between the overload relays.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-23**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**Accessories 1**
## _**Auxiliary Contacts**_
Front-mounted snap-on auxiliary contacts for mini contactors are available with screw terminals in a variety of contact configurations. Auxiliary contact modules are standard with interlocked opposing contacts, except in the case of early-make or late-break contacts.
## **Front-Mount Auxiliary Contacts for Use with Mini Contactors**
|**Front-Mount Auxiliary Contacts for Use with Mini Contactors**|**Front-Mount Auxiliary Contacts for Use with Mini Contactors**|**Front-Mount Auxiliary Contacts for Use with Mini Contactors**|**Front-Mount Auxiliary Contacts for Use with Mini Contactors**|**Front-Mount Auxiliary Contacts for Use with Mini Contactors**|**Front-Mount Auxiliary Contacts for Use with Mini Contactors**|
|---|---|---|---|---|---|
|**Conventional Free Air**<br>**Thermal Current,**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Contact Sequence**<br>**Pkg.**<br>**Qty.**1<br>**Screw Terminal**<br>**Catalog Number**||||||
|10<br>2NC||5<br>**XTMCXFC02**<br>21<br>22<br>31<br>32||||
|10<br>1NO-1NC||5<br>**XTMCXFD11**<br>21<br>22<br>33<br>34||||
|10<br>2NO-2NC|21<br>22|5<br>**XTMCXFC22**<br>31<br>32<br>43<br>44<br>53<br>54||||
|10<br>2NC||5<br>**XTMCXFA02**<br>51<br>52<br>61<br>62||||
|10<br>1NO-1NC||5<br>**XTMCXFA11**<br>54<br>53<br>61<br>62||||
|10<br>2NO||5<br>**XTMCXFA20**<br>54<br>63<br>64<br>53||||
|10<br>4NC||5<br>**XTMCXFA04**<br>1<br>2<br>61<br>62<br>71<br>72 82<br>81||||
||5<br>5|1<br>2<br>61<br>62|7|2 8<br>8|8|
||||7|||
|||||||
|10<br>1NO-3NC||5<br>**XTMCXFA13**<br>3 61 71<br>81<br>82<br>72<br>62<br>4||||
||5|3 61|7|8<br>8<br>2|8|
|||||||
||5|62<br>4|7|||
|||||||
|10<br>2NO-2NC||5<br>**XTMCXFA22**<br>4<br>3 61<br>62<br>71<br>72<br>83<br>84||||
||5|3 61|7|1||
|||||||
||5|4<br>62|7|2||
|||||||
|10<br>3NO-1NC||5<br>**XTMCXFA31**<br><br><br>61<br>62<br>73<br>74<br>83<br>84||||
||5|61|73|||
||54|62|74|||
|||||||
|10<br>4NO||5<br>**XTMCXFA40**<br>4<br>63 73<br>64 74<br>3<br>83<br>84||||
||5|63 73<br>3||||
||5|4<br>64 74||||
|||||||
|10<br>1NO-1NC<br>1NOE-1NCL||5<br>**XTMCXFAL22**2<br>8<br>7 65<br>66<br>71<br>72<br>83<br>84||||
||5|||||
||5|||||
## _**Notes**_
1 Orders must be placed in multiples of package quantity listed.
- 2 One early-make contact (NOE), one late-break contact (NCL).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-24**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Suppressors**_
|**XTMCXR_**|**RC Suppressor**1|**RC Suppressor**1||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||**For Use**||||||||**Pkg.**||
||**Voltage**|**with…**|**Circuit Symbol**<br>**Qty.**2||||||||**Catalog Number**|
||24–48|XTMC6A_,|A1|||||||10|**XTMCXRSW**|
|||XTMC9A_||||||||||
|48–130<br>**XTMC Relay with**<br>**Installed Suppressor**||XTMC6A_,<br>XTMC9A_|A2|||||||10|**XTMCXRSA**|
||110–250|XTMC6A_,||||||||10|**XTMCXRSB**|
|||XTMC9A_||||||||||
## **XTMCXR_**
## **Varistor Suppressor**[3]
||**Varistor Suppressor**|**Varistor Suppressor**[3]|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**XTMCX_**|**Varistor Suppressor**|**Varistor Suppressor**[3]|||||||||||
|||**For Use**|||||||||**Pkg.**||
||**Voltage**|**with…**|**Circuit Symbol**<br>**Qty.**2|||||||||**Catalog Number**|
||24–48|XTMC6A_,|A1||||||||10|**XTMCXVSW**|
|||XTMC9A_|||||||||||
||||||||||||||
|48–130<br>**XTMC Relay with**<br>**Installed Suppressor**||XTMC6A_,<br>XTMC9A_|A2||||||||10|**XTMCXVSA**|
||110–250|XTMC6A_,|||||||||10|**XTMCXVSB**|
|||XTMC9A_|||||||||||
||380–415|XTMC6A_,|||||||||10|**XTMCXVSN**|
|||XTMC9A_|||||||||||
## _**Mechanical Interlock**_
## **XTMCXML**
## **Mechanical Interlock**
||**Pkg.**||
|---|---|---|
|**Description**|**Qty.**2|**Catalog Number**|
|Mechanical interlock|5|**XTMCXML**|
## _**Notes**_
For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted, the distance between contactors is 0 mm and the mechanical lifespan is 2.5 x 10[6] operations.
- 1 For AC operated contactors, 50/60 Hz. Note dropout delay.
- 2 Orders must be placed in multiples of package quantity listed.
- 3 For AC operated contactors, 50/60 Hz. DC operated contactors have integrated varistor suppressors.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-25**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Additional Accessories**_
**XTMCXRL**
**Reversing Link Kit**[12]
|**Reversing Link Kit**[12]<br>**XTMCXRL**|**Reversing Link Kit**[12]<br>**XTMCXRL**|**Reversing Link Kit**[12]<br>**XTMCXRL**|**Reversing Link Kit**[12]<br>**XTMCXRL**|
|---|---|---|---|
|**Description**<br>**Pkg.**<br>**Qty.**3<br>**Catalog Number**<br>Main current wiring for reversing contactors and starters<br>1<br>**XTMCXRL**<br>~~wm~~<br>canes||||
|**XTMCXSDL**|**Star-Delta (Wye-Delta) Link Kit**45|||
|8|**Description**<br>Main current wiring for star-delta (wye-delta) combinations.<br>Includes the star-delta bridge|**Pkg.**<br>**Qty.**3<br>1|**Catalog Number**<br>**XTMCXSDL**|
|**XTMCXCN**|**Connector**|||
|BO|**Description**<br>For mechanically arranging contactors and timing relays in<br>combinations|**Pkg.**<br>**Qty.**3<br>50|**Catalog Number**<br>**XTMCXCN**6|
|**XTMCXSHROUD**|**IP40 Sealable Transparent Shroud**|**Pkg.**||
||**Description**<br>IP40 sealable transparent shroud, snap fitting on mini contactor|**Qty.**3<br>1|**Catalog Number**<br>**XTMCXSHROUD**|
## _**Notes**_
1 The following control cables are integrated as part of the electrical interlock: K1M: A1–K2M: 21; K1M: 21–K2M: A1
2 Reversing link kit does not include mechanical interlock. See Mechanical Interlock.
- 3 Orders must be placed in multiples of package quantity listed.
4 The following control cables are integrated in addition to the electrical interlock: K3M: A1–K5M: 21; K3M: 21–K5M: A1; K3M: A2–K5M: A2
- 5 When combined with overload relay, use separate mounting.
- 6 0 mm distance between contactors.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-26**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Technical Data and Specifications**
_**XT**_ **Miniature Controls—General**
|**_XT_ Miniature Controls—General**|||||||
|---|---|---|---|---|---|---|
||**XTMC6A_**||**XTMC9A_**||**XTMF9A_**||
|**Description**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|
|**Physical and Electrical**|||||||
|Standards|IEC/EN 60947,<br>VDE 0660, CSA,|IEC/EN 60947,<br>VDE 0660, CSA,|IEC/EN 60947,<br>VDE 0660, CSA,|IEC/EN 60947,<br>VDE 0660, CSA,|IEC/EN 60947,<br>VDE 0660, CSA,|IEC/EN 60947,<br>VDE 0660, CSA,|
|Weights in kg [lb]|UL, CCC<br>0.2 [0.44]|UL, CCC<br>0.17 [0.37]|UL, CCC<br>0.2 [0.44]|UL, CCC<br>0.17 [0.34]|UL, CCC<br>0.2 [0.44]|UL, CCC<br>0.17 [0.37]|
|Mechanical life—operations|10,000,000|20,000,000|10,000,000|20,000,000|10,000,000|10,000,000|
|Mechanical life—coil at 50 Hz|7|—|7|—|7|—|
|Maximum mechanical operating frequency (ops/hr)|9000|9000|9000|9000|9000|9000|
|Insulation voltage (Ui) Vac<br>Impulse withstand voltage (Uimp) Vac|690<br>6000|690<br>6000|690<br>6000|690<br>6000|690<br>6000|690<br>6000|
|Operational Voltage (Ue) Vac<br>Safe isolation to VDE 0106 Part 101 and Part 101/A1|690|690|690|690|690|690|
|Between coil and contacts (Vac)|300|300|300|300|300|300|
|Between contacts (Vac)|300|300|300|300|300|300|
|Making capacity (amps)|110|110|110|110|110|110|
|Breaking capacity (amps)<br>220/230V|90|90|90|90|90|90|
|380/400V|90|90|90|90|90|90|
|500V|64|64|64|64|64|64|
|660/690V|54|54|54|54|54|54|
|Short-circuit protection rating maximum fuse (gL/gG)|||||||
|Type 2 coordination (A)|10|10|10|10|10|10|
|Type 1 coordination (A)<br>Degree of protection|20<br>IP20|20<br>IP20|20<br>IP20|20<br>IP20|20<br>IP20|20<br>IP20|
|Flexible with ferrule (mm2)|1 x (0.75–1.5)<br>2 x (0.75–1.5)|1 x (0.75–1.5)<br>2 x (0.75–1.5)|1 x (0.75–1.5)<br>2 x (0.75–1.5)|1 x (0.75–1.5)<br>2 x (0.75–1.5)|1 x (0.75–1.5)<br>2 x (0.75–1.5)|1 x (0.75–1.5)<br>2 x (0.75–1.5)|
|Solid or stranded (AWG)|18–14|18–14|18–14|18–14|18–14|18–14|
|Terminal screw|M3.5|M3.5|M3.5|M3.5|M3.5|M3.5|
|Pozidriv screwdriver|Size 2|Size 2|Size 2|Size 2|Size 2|Size 2|
|Standard screwdriver (mm)|0.8 x 5.5|0.8 x 5.5|0.8 x 5.5|0.8 x 5.5|0.8 x 5.5|0.8 x 5.5|
||1 x 6|1 x 6|1 x 6|1 x 6|1 x 6|1 x 6|
|Max. tightening torque|||||||
|Nm|1.2|1.2|1.2|1.2|1.2|1.2|
|Lb-in|10.6|10.6|10.6|10.6|10.6|10.6|
|Terminal capacity of spring cage main terminals|||||||
|Solid (mm2)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|
|Flexible with ferrule (mm2)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|1 x (1–2.5)<br>2 x (1–2.5)|
|Standard screwdriver (mm)<br>Mounting position|0.6 x 3.5<br>1|0.6 x 3.5<br>1|0.6 x 3.5<br>1|0.6 x 3.5<br>1|0.6 x 3.5<br>1|0.6 x 3.5<br>1|
## _**Note**_
> 1 As required, except vertical with terminals A1/A2 at the bottom.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-27**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## _**XT**_ **Miniature Controls—General, continued**
||**XTMC6A_**||**XTMC9A_**||**XTMF9A_**||
|---|---|---|---|---|---|---|
|**Description**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|
|**Environmental**|||||||
|Ambient temperature|–25° to 50°C|–25° to 50°C|–25° to 50°C|–25° to 50°C|–25° to 50°C|–25° to 50°C|
||[–13° to 122°F]|[–13° to 122°F]|[–13° to 122°F]|[–13° to 122°F]|[–13° to 122°F]|[–13° to 122°F]|
|Mechanical shock resistance (IEC/EN 60068-2-27)|||||||
|Half-sinusoidal shock 10 ms|||||||
|Contactor without auxiliary contact module|||||||
|Main contact—make contact|10g|10g|10g|10g|10g|10g|
|Main contact—break/make contact|10/8g|10/8g|10/8g|10/8g|—|—|
|Contactor with auxiliary contact module|||||||
|Main contact—make contact|10g|10g|10g|10g|10g|10g|
|Main contact—make/break contact<br>Climatic proofing|20/20g<br>1|20/20g<br>1|20/20g<br>1|20/20g<br>1|20/20g<br>1|20/20g<br>1|
|Pollution degree|III/3|III/3|III/3|III/3|III/3|III/3|
## _**Note**_
> 1 Damp heat, constant, to IEC 60 068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-28**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
_**XT**_ **Miniature Controls—Magnet Systems**
||**XTMC6A_**||**XTMC9A_**||**XTMF9A_**||
|---|---|---|---|---|---|---|
|**Description**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|
|**Voltage Tolerance**|||||||
|Pickup (x Uc)|||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz|0.8–1.1|—|0.8–1.1|—|0.8–1.1|—|
|Dual frequency coil 50/60 Hz|0.85–1.1|—|0.85–1.1|—|0.85–1.1|—|
|DC operated1<br>**Power Consumption**|—|0.8–1.1|—|0.8–1.1|—|0.85–1.1|
|AC operation|||||||
|Pickup VA|||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz|25|—|25|—|25|—|
|Dual frequency coil 50/60 Hz at 50 Hz<br>Dual frequency coil 50/60 Hz at 60 Hz|30<br>29|—<br>—|30<br>29|—<br>—|30<br>29|—<br>—|
|Pickup W|||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz|22|—|22|—|22|—|
|Dual frequency coil 50/60 Hz at 50 Hz|26|—|26|—|26|—|
|Dual frequency coil 50/60 Hz at 60 Hz|24|—|24|—|24|—|
|Sealing VA|||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz<br>Dual frequency coil 50/60 Hz at 50 Hz|4.6<br>5.4|—<br>—|4.6<br>5.4|—<br>—|4.6<br>5.4|—<br>—|
|Dual frequency coil 50/60 Hz at 60 Hz|3.9|—|3.9|—|3.9|—|
|Sealing W|||||||
|Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz|1.3|—|1.3|—|1.3|—|
|Dual frequency coil 50/60 Hz at 50 Hz|1.6|—|1.6|—|1.6|—|
|Dual frequency coil 50/60 Hz at 60 Hz|1.1|—|1.1|—|1.1|—|
|DC operated1<br>Power consumption pickup = sealing (VA/W)|—|2.6|—|2.6|—|2.6|
|Duty factor (%)|100|100|100|100|100|100|
|**Switching Time at 100% Uc**|||||||
|Make contact|||||||
|Closing delay min. (ms)|14|26|14|26|14|26|
|Closing delay max. (ms)|21|35|21|35|21|35|
|Opening delay min. (ms)<br>Opening delay max. (ms)|8<br>18|15<br>25|8<br>18|15<br>25|8<br>18|15<br>25|
|Closing delay with top-mounting auxiliary contact (ms)|Max. 45|Max. 70|Max. 45|Max. 70|Max. 45|Max. 70|
|**Reversing Contactors**|||||||
|Changeover time at 100% Uc|||||||
|Minimum (ms)|16|40|16|40|16|40|
|Maximum (ms)|21|50|21|50|21|50|
|Arcing time at 690 Vac (ms)|Max. 12|Max. 12|Max. 12|Max. 12|Max. 12|Max. 12|
## _**Note**_
> 1 Smoothed DC or three-phase bridge rectifier.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-29**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## _**XT**_ **Miniature Controls**
|**_XT_ Miniature Controls**|||||||
|---|---|---|---|---|---|---|
||**XTMC6A_**||**XTMC9A_**||**XTMF9A_**||
|**Description**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|
|**AC-1 Operation**|||||||
|Conventional free air thermal current, three-pole, 50–60 Hz (A)|||||||
|at 40°C (Ith)|22|22|22|22|22|22|
|at 50°C (Ith)|20|20|20|20|20|20|
|at 55°C (Ith)<br>Conventional free air thermal current, single-pole (Ith)|19<br>50|19<br>50|19<br>50|19<br>50|19<br>60|19<br>60|
|**AC-3 Operation**<br>Rated operational current, 50/60 Hz1(Ie) in amperes (A)|||||||
|220/230V|6.6|6.6|9.0|9.0|9.0|9.0|
|240V|6.6|6.6|9.0|9.0|9.0|9.0|
|380/400V|6.6|6.6|9.0|9.0|9.0|9.0|
|415V|6.6|6.6|9.0|9.0|9.0|9.0|
|440V|6.6|6.6|9.0|9.0|9.0|9.0|
|500V<br>660/690V|5.0<br>3.5|5.0<br>3.5|6.4<br>4.8|6.4<br>4.8|6.4<br>4.8|6.4<br>4.8|
|Rated power (P) in kilowatts (kW)|||||||
|220/230V|1.5|1.5|2.2|2.2|2.2|2.2|
|240V|1.8|1.8|2.5|2.5|2.5|2.5|
|380/400V|3.0|3.0|4.0|4.0|4.0|4.0|
|415V|3.1|3.1|4.3|4.3|4.3|4.3|
|440V<br>500V|3.3<br>3.0|3.3<br>3.0|4.6<br>4.0|4.6<br>4.0|4.6<br>4.0|4.6<br>4.0|
|660/690V|3.0|3.0|4.0|4.0|4.0|4.0|
|**AC-4 Operation**|||||||
|Rated operational current, 50/60 Hz1(Ie) in amperes (A)|||||||
|220/230V|5.0|5.0|6.6|6.6|6.6|6.6|
|240V|5.0|5.0|6.6|6.6|6.6|6.6|
|380/400V<br>415V|5.0<br>5.0|5.0<br>5.0|6.6<br>6.6|6.6<br>6.6|6.6<br>6.6|6.6<br>6.6|
|440V<br>500V|5.0<br>3.7|5.0<br>3.7|6.6<br>5.0|6.6<br>5.0|6.6<br>5.0|6.6<br>5.0|
|660/690V|2.9|2.9|3.4|3.4|3.4|3.4|
|Rated power (P) in kilowatts (kW)|||||||
|220/230V|1.1|1.1|1.5|1.5|1.5|1.5|
|240V|1.3|1.3|1.8|1.8|1.8|1.8|
|380/400V|2.2|2.2|3.0|3.0|3.0|3.0|
|415V<br>440V|2.3<br>2.4|2.3<br>2.4|3.1<br>3.3|3.1<br>3.3|3.1<br>3.3|3.1<br>3.3|
|500V|2.2|2.2|3.0|3.0|3.0|3.0|
|660/690V|2.2|2.2|3.0|3.0|3.0|3.0|
|**DC-1 Operation**2|||||||
|12V|20|20|20|20|—|—|
|24V|20|20|20|20|—|—|
|60V<br>110V|20<br>20|20<br>20|20<br>20|20<br>20|—<br>—|—<br>—|
|220V|20|20|20|20|—|—|
## _**Notes**_
> 1 At maximum permissible ambient temperature.
> 2 Rated operation current (le) in amperes, at maximum permissible ambient temperature.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-30**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**XT**_ **Miniature Controls, continued**
|**_XT_ Miniature Controls, continued**|||||||
|---|---|---|---|---|---|---|
||**XTMC6A_**||**XTMC9A_**||**XTMF9A_**||
|**Description**<br>**DC-3 Operation**1|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|**AC Coils**|**DC Coils**|
|12V|6|6|8|8|—|—|
|24V|6|6|8|8|—|—|
|60V|3|3|4|4|—|—|
|110V|2|2|3|3|—|—|
|220V|—|—|—|—|1.0|1.0|
|**DC-4 Operation**1<br>12V|1.8|1.8|2.5|2.5|—|—|
|24V<br>60V|1.8<br>1.8|1.8<br>1.8|2.5<br>2.5|2.5<br>2.5|—<br>—|—<br>—|
|110V<br>220V|1.1<br>0.2|1.1<br>0.2|1.5<br>0.3|1.5<br>0.3|2.5<br>1.0|2.5<br>1.0|
|**Current Heat Loss (Three- or Four-Pole) in Watts**|||||||
|at Ith|2.0|3.5|2.0|3.5|2.7|4.7|
|at Ie to AC-3/400V|0.3|0.4|0.5|0.7|—|—|
## _**XT**_ **Miniature Controls—Auxiliary Contacts**
|**_XT_ Miniature Controls—Auxiliary Contacts**|||
|---|---|---|
||**Built-In Auxiliary**|**Add-On Auxiliary**|
|**Description**|**XTMC**|**XTMCXF_**|
|Interlocked opposing contacts to ZH1/457, including auxiliary contact module|Yes|Yes|
|Rated impulse withstand voltage, Uimp(Vac)<br>Overvoltage category/pollution degree|6000<br>III/3|6000<br>III/3|
|Rated insulation voltage, Ui(Vac)<br>Rated operational voltage, Ue(Vac)|690<br>600|690<br>600|
|Safe isolation to VDE 0106 Part 101 and Part 101(A) in Vac|||
|Between coil and auxiliary contacts|300|300|
|Between the auxiliary contacts|300|300|
|Rated operational current|||
|AC-15, Ie|||
|220/240V<br>380/415V|6A<br>3A|4A<br>2A|
|500V|1.5A|1.5A|
|DC-13 (contacts in series)|||
|1: 24V|2.5A|2.5A|
|2: 60V|2.5A|2.5A|
|3: 100V|1.5A|1.5A|
|3: 220V|0.5A|0.5A|
|Conventional thermal current, Ith|10A|10A|
|Control circuit reliability (at Ue= 24 Vdc, Umin= 17V, Imin= 5.4 mA)<br>Component lifespan at Ue= 240V|<10–8, <1 failure at 100 million operations|<10–8, <1 failure at 100 million operations|
|AC-15, operations x 106|0.2|0.2|
|DC-13 L/R = 50 ms: 2 contacts in series at Ie= 0.5A, operations x 106|0.15|0.15|
|Short-circuit rating without welding|||
|Short-circuit protection rating maximum fuse, 500V gG/gL|6A|6A|
|Short-circuit protection rating maximum fuse, 500V fast|10A|10A|
|Current heat loss at conventional free air thermal current Ithper contact, W|0.2|0.2|
## _**Note**_
> 1 Rated operation current (le) in amperes, at maximum permissible ambient temperature.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-31**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Wiring Diagrams**
## **XTMR Reversing Contactor Control Circuit**
**XTMR Reversing Contactor**
**Power Circuit**
**==> picture [232 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
21<br>0<br>22<br>22 1 3 5 1 3 5<br>21<br>II K1M K2M<br>22 21<br>2 4 6 2 4 6<br>54 53<br>I<br>53 54<br>54<br>54<br>K1M 53 K2M 53<br>22 K1M 22 U V W<br>K2M 21<br>21 M<br>A1 K2M A1 M1 3<br>K1M<br>A2 A2<br>**----- End of picture text -----**<br>
_**XT**_ **Mini Star-Delta (Wye-Delta) Contactor Power Circuit**
**==> picture [146 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>1 3 5 1 3 5 1 3 5<br>K1M K5M K3M<br>2 4 6 2 4 6 2 4 6<br>A C<br>U1 V2<br>V1 M1 W2<br>W1 3 U2<br>M1<br>**----- End of picture text -----**<br>
## **Tripping Characteristics**
## **Tripping Characteristics Chart**
**==> picture [156 x 212] intentionally omitted <==**
**----- Start of picture text -----**<br>
2h<br>100 XTOM<br>60<br>40<br>20<br>10<br>6<br>4<br>2<br>1<br>40<br>3-Phase<br>20<br>10<br>6<br>4<br>2-Phase<br>2<br>1<br>0.6<br>1 1.5 2 3 4 6 8 10 15 20<br>x Setting Current<br>Minutes<br>Seconds<br>**----- End of picture text -----**<br>
These tripping characteristics are mean values of the spread at 20°C ambient temperature in a cold state. Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found on **Page V5-T1-33** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-32**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Electrical Switching Operation Charts**
Squirrel cage motors
Operating characteristics Starting: from rest Stopping: after attaining a full running speed
Electrical characteristics Make (NO): Up to 6x rated motor current Breaking (NC): 1x rated motor current
## **Normal Switching Duty—AC-3/400V**
**==> picture [227 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC-3/400V<br>kW<br>A<br>30 58<br>22 43<br>18.5 36<br>15 30<br>11 23<br>7.5 16<br>5.5 12<br>4 8.8 XTMC 9A<br>3 6.5 XTMC 6A<br>2.2 5<br>XTMC DC Coil<br>1.5 3.5<br>1.1 2.5<br>XTMC AC Coil<br>0.8 2<br>0.55 1.6<br>0.01 0.04 0.1 0.4 0.75 2 4 6 10<br>0.02 0.06 0.2 0.6 1 3 5 8<br>Component lifespan (millions of operations)<br>Rated operational current l 50 – 60 Hze<br>Rated output of three-phase motors, 50 – 60 Hz<br>**----- End of picture text -----**<br>
## **Switching Duty for Non-Motor Loads, Three- and Four-Pole—AC-1/400V**
**==> picture [216 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
1400<br>AC-1/400V<br>1000<br>700<br>500<br>350<br>275<br>160<br>100<br>55<br>35<br>XTMC 6A<br>20 XTMC 9A<br>10<br>7<br>5<br>4<br>3<br>2<br>1<br>0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10<br>Component lifespan (millions of operations)<br>Breaking current<br>**----- End of picture text -----**<br>
Squirrel cage motors
Operating characteristics Jogging, plugging, reversing
Electrical characteristics Make (NO): 6x rated motor current Breaking (NC): 6x rated motor current
## **Extreme Switching Duty—AC-4/400V**
**==> picture [229 x 508] intentionally omitted <==**
**----- Start of picture text -----**<br>
kW A AC-4/400V<br>22 43<br>18.5 36<br>15 30<br>11 23<br>7.5 16<br>5.5 12<br>4 8.8<br>3 6.5 XTMC 9A<br>2.2 5 XTMC 6A<br>1.5 3.5<br>1.1 2.5<br>0.8 2<br>0.55 1.6<br>0.37 1.2<br>0.25 0.8<br>0.01 0.03 0.06 0.2 0.4 1 3 5 8<br>0.02 0.04 0.1 0.3 0.6 2 4 6 10<br>Component lifespan (millions of operations)<br>Short Time Loading, Three-Pole—AC-1/400V<br>(time interval between two loading cycles: 15 minutes)<br>A AC-1/400V<br>700<br>500<br>400<br>300<br>200<br>150<br>100<br>XTMC 6A<br>70 XTMC 9A<br>50<br>40<br>30<br>20<br>15<br>Seconds 2 3 5 7 10 20 30 50 70 100 200 300 500700 900<br>Duration of load 1 min 3 min 10 min<br>5 min 15 min<br>Rated operational current l 50 – 60 Hze<br>Rated output of three-phase motors, 50 – 60 Hz<br>Short-time current<br>**----- End of picture text -----**<br>
**Short Time Loading, Three-Pole—AC-1/400V (time interval between two loading cycles: 15 minutes)**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-33**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Dimensions**
Approximate Dimensions in mm [in.]
## **Non-Reversing Mini Contactor**
**==> picture [217 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
D M4<br>58 50<br>[2.28] [1.97]<br>35<br>[1.38]<br>45 D1<br>[1.77]<br>XTMC XTMCC<br>D 52 [2.05] 54 [2.13]<br>D1 83 [3.27] 86 [3.39]<br>**----- End of picture text -----**<br>
## **Star-Delta Starter Combinations**
**==> picture [239 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
61<br>[2.40]<br>180 83<br>[7.09] [3.27]<br>108<br>[4.25]<br>**----- End of picture text -----**<br>
## **Reversing Mini Contactor**
**==> picture [219 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
61<br>[2.40]<br>108<br>[4.25]<br>90 94<br>[3.54] [3.70]<br>**----- End of picture text -----**<br>
## **Non-Reversing Mini Contactor with Overload Relay**
**==> picture [192 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.5 [.22]<br>106 49<br>[4.17] [1.93]<br>32 58<br>[1.26] [2.28]<br>45<br>≥ 5 [.20]<br>[1.77]<br>**----- End of picture text -----**<br>
## **XTMCXRSA, XTMCXVSA Mini Suppressors**
**==> picture [129 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
62.5<br>[2.46]<br>45 52<br>[1.77] [2.05]<br>**----- End of picture text -----**<br>
## **XTMCXTSA Mini Sealable Shroud**
**==> picture [201 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
43<br>[1.69]<br>58 45<br>[2.28] [1.77]<br>45 69<br>[1.77] [2.72]<br>XTMCXML Mechanical Interlock<br>58<br>[2.28]<br>90 63<br>[3.54] [2.48]<br>58<br>[2.28]<br>90 94<br>[3.54] [3.70]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-34**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **XT Family of Contactors**
## **Contents**
|**Contents**|**Contents**|**Contents**||
|---|---|---|---|
|**_Description_**|||**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .<br>Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|||**V5-T1-3**<br>**V5-T1-18**|
|Contactors and Starters||||
|Product Identification . . . . . . . . . . . . . . . . . . . .|||**V5-T1-36**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|||**V5-T1-38**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|||**V5-T1-39**<br>**V5-T1-65**|
|Technical Data and Specifications . . . . . . . . . . .<br>Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|||**V5-T1-78**<br>**V5-T1-109**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>An Eaton|||**V5-T1-114**|
|||Green Solution||
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .||Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|||**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .|||**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|||**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .<br>EMS—Electronic Motor Starter . . . . . . . . . . . . . . .|||**V5-T1-217**<br>**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . .<br>Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|||**V5-T1-232**<br>**V5-T1-234**|
**1**
## **Contactors and Starters**
## **Product Description**
The Eaton _**XT**_ contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories. Because _**XT**_ meets IEC, UL[®] , CSA[®] and CE standards, it is the perfect product solution for IEC applications all over the world. The compact, space saving and easy to install _**XT**_ line of IEC contactors and starters is the efficient and effective solution for customer applications from 7A to 2450A.
## **Application Description**
The _**XT**_ line of IEC power control was engineered to provide highly effective control and protection for a variety of loads, including motors, compressors, pumps, resistive, capacitor banks, isolation, and others. _**XT**_ also includes IEC ratings for lighting applications as well.
_**XT**_ contactors can be used in safety applications according to EN 954-1, EN ISO 13849-1 and IEC 62061 up to Category 4, Pl e and SIL 3. Information concerning safety related characteristics (B10 and B10d values) is available online. The auxiliary contact modules and built-in auxiliary contacts meet IEC EN 60947-5-1 Annex L (positively driven) and IEC EN 60947-4-1 Annex F (mirror contacts).
## **Features and Benefits**
- AC control from 12V to 600V 50/60 Hz
- DC control from 12V to 220V
- Available with screw or spring cage terminals
- Reversing or non-reversing contactors and starters
- AC-3 contactor ratings to 1000A and AC-1 contactor ratings to 2000A
- Non-reversing starters to 650A
- Panel or DIN rail mounting to 65A
- IP20 finger and back-ofhand proof
- Large ambient temperature range, –25 to 50°C [–13 to 122°F]
- AC and DC controlled contactors in the same compact frame
- Low power consumption AC and DC coils
- Built-in NO or NC auxiliary contacts to 32A
- Plug-in accessories for reduced installation time
- Coil replacement on Frames C–N (18–820A)
- Contact replacement on Frames D–N (40 –820A)
- Integrated suppressor 7–150A DC operated contactors and 185–2000A AC and DC operated contactors
## **Standards and Certifications**
- IEC EN 60947
- CE approved
- UL
- CSA
- RoHS
**Note:** For Type 2 Coordination, see **Page V5-T1-235** .
## **Reference**
Refer to **Volume 10—Enclosed Control** , CA08100012E, Tab 3, section 3.1 for additional product information on IEC Non-Metallic Enclosed Contactors and Starters.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-35**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## **Product Identification**
## _**XTCE007B to XTCE170G (7 to 170A) Contactors**_
**==> picture [449 x 459] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 1 4 4 Mg<br>Lf vag 4<br>meee nae = 1<br>5 1<br>Ll<br>—| Se | .<br>;<br>r<br>4, * &/p 2 ]<br>©<br>7 ea 7<br>2 Ah VAY,<br>3 al 4<br>® © 6<br>3<br>4<br>4 3<br>7 4 aah<br>4 2<br>3<br>i oo. ae |<br>;<br>2900 3 18 fe |<br>| ae = =7<br>4<br>4<br>4 nan Sp<br>| | Roar y (eoAADeea<br>Notes<br>1 Contactor up to 170A AC-3 (see Page V5-T1-39 )<br>AC: 12–600V, 50, 60, 50/60 Hz<br>0.8–1.1 x Uc)<br>DC: 12–250V<br>XTCE…B_ (7–15A): 0.8–1.1 x Uc<br>XTCE…C_–XTCE…G_(18–150A): 0.7–1.2 x Uc<br>24V: 0.7–1.3 x Uc at 40°C without additional auxiliary contacts<br>Coils for special voltages<br>“Safe Isolation” to IEC 536 between coil and contacts<br>2 Suppressors (see Page V5-T1-71 )<br>RC suppressor<br>Varistor suppressor<br>Free-wheel diode suppressor<br>**----- End of picture text -----**<br>
- 3 **Overload Relays** (see **Page V5-T1-130** ) Can be mounted directly Separate mounting, possible Protection of EEx e-motors
- 4 **Auxiliary Contact Modules** (see **Page V5-T1-24** ) Two-pole, plug-in type Four-pole, plug-in type Overlapping contacts Two-pole, side-mounting
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-36**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**XTCE185–XTCE20 Contactors**_
**==> picture [322 x 329] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>3<br>1<br>=g<br>7<br>ea<br>4<br>Gn! \<br><j<br>Zi<br>A’ Vy a) Ry 5<br>| és a”. —<br>6<br>**----- End of picture text -----**<br>
## _**Notes**_
- 1 **XTCE Contactors for 185–2000A** (see **Page V5-T1-46** ) Multi-voltage coils:
- 24–48 Vdc
- 48–110 Vac/Vdc
- 110–250 Vac/Vdc
- 250–500 Vac
- 0.7–1.15 x Uc
- Actuation options: Directly From the PLC With low-consumption contact
## **XTCS Contactors for 185–570A AC-3**
## 2 **Cable Terminal Block**
- (see **Page V5-T1-97** )
- One or two conductors per phase Round and flat conductor connectable Finger-proof
- 3 **Flat Strip Conductor Terminals** (see **Page V5-T1-97** )
- One or two strips per phase Control circuit terminal Cover for fingerproofing
- 4 **Mechanical Interlock** (see **Page V5-T1-73** ) Fits between contactors
- 5 **Overload Relays**
- (see **Page V5-T1-130** )
- Can be mounted directly Separate mounting, possible Protection of EEx e-motors PTB certificate
- 6 **Terminal Shroud** (see **Page V5-T1-75** ) Finger-proof
- 7 **Auxiliary Contact Modules** (see **Page V5-T1-24** ) Two-pole, side-mounting
- (see **Page V5-T1-42** ) Control voltages: 110–120V 50/60 Hz 220–240V 50/60 Hz Conventional operation
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-37**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **IEC Contactors and Starters**
**XT CE C 007 B 01 AD P16 Designation XTAE, XTAS and XTAR Starters Only—** _**XT**_ = _**XT**_ line of IEC control **Maximum Overload Relay Terminations Coil Codes XTOB Maximum Overload Rating Type Blank** = Screw terminals See **Page Frame B Frame D CECSCFCRCCAE** ====== Three-pole FVNR S Series IEC contactorThree-pole FVR IEC contactorThree-pole FVNR IEC contactorFour-pole FVNR IEC contactorIEC capacitor contactorFVNR IEC starter **C** = terminals consult (6–65A); 5 mm (80–150A); no lugs (185–2000A)Spring cage **Built-In Auxiliary Contact01** = 1NC **V5-T1-53** . **P16P24P40P600011P6** ====== 0.6–1A0.1–0.16A0.24–0.4A0.4–0.6A1.0–1.6A0.16–0.24A **010016024040057065** ====== 6–10A10–16A16–24A24–40A40–57A50–65A **AS** = FVNR S-Series IEC starter local sales office **10** = 1NO **2P4** = 1.6–2.4A **075** = 65–75A **AR** = FVR IEC starter for availability **00** = 0NO–0NC **004** = 2.4–4A **S1** = 1NO–1NC **006** = 4–6A **Frame F** side-mount auxiliary **010** = 6–10A **035** = 25–35A **Current Ratings, AC-3 11** = 1NO–1NC **012** = 9–12A **050** = 35–50A top-mount auxiliary **016** = 12–16A **070** = 50–70A **007** = 7A **080** = 80A **570** = 570A **22** = 2NO–2NC **100** = 70–100A **009** = 9A **095** = 95A **580** = 580A **012** = 12A **115** = 115A **650** = 650A **Frame C Frame G 015** = 15A **150** = 150A **750** = 750A **P16** = 0.1–0.16A **035** = 25–35A **018025** = 18A = 25A **170 185** = 185A= 170A **820C10** = 820A = 1000A **Frame Size Designation P24P40** == 0.24–0.4A0.16–0.24A **050070** == 35–50A50–70A **032** = 32A **225** = 225A **C14** = 1400A, AC-1 **B** = 45 mm **L** = 140 mm **P60** = 0.4–0.6A **100** = 70–100A **040** = 40A **250** = 250A **C16** = 1600A, AC-3 **C** = 45 mm **M** = 160 mm **001** = 0.6–1A **125** = 95–125A **050** = 50A **300** = 300A **C20** = 2000A, AC-1 **D** = 55 mm **N** = 250 mm **1P6** = 1.0–1.6A **150** = 120–150A **065** = 65A **400** = 400A **F** = 90 mm **P** = 260 mm **2P4** = 1.6–2.4A **175** = 145–175A **072** = 72A **500** = 500A **G** = 90 mm **R** = 515 mm **004** = 2.4–4A **H** = 140 mm
|**Frame**<br>**P16** = <br>**P24** = <br>**P40** = <br>**P60** = <br>**001**<br>= <br>**1P6** = <br>**2P4** = <br>**004**<br>= <br>**006**<br>=|**Frame**<br>**P16** = <br>**P24** = <br>**P40** = <br>**P60** = <br>**001**<br>= <br>**1P6** = <br>**2P4** = <br>**004**<br>= <br>**006**<br>=|**C**<br> 0.1–0.16A<br> 0.16–0.24A<br> 0.24–0.4A<br> 0.4–0.6A<br> 0.6–1A<br> 1.0–1.6A<br> 1.6–2.4A<br> 2.4–4A<br> 4–6A|**Frame**<br>**035**<br>= <br>**050**<br>= <br>**070**<br>= <br>**100**<br>= <br>**125**<br>= <br>**150**<br>= <br>**175**<br>= <br>**Frame**|**G**<br> 25–35A<br> 35–50A<br> 50–70A<br> 70–100A<br> 95–125A<br> 120–150A<br> 145–175A<br>**L**|
|---|---|---|---|---|
|**010**<br>**016**|= <br>=|6–10A<br> 10–16A|**070**<br>= <br>**100**<br>=|50–70A<br> 70–100A|
|**024**|=|16–24A|**125**<br>=|95–125A|
|**032**|=|24–32A|**160**<br>= <br>**220**<br>=|120–160A<br> 160–220A|
||||**250**<br>=|200–250A|
||**XTOE Maximum**|**Overload Rating**|**Overload Rating**||
|---|---|---|---|---|
|||**Standard**||**Ground Fault**|
|||**Type Suffix**||**Type Suffix**|
||**Frame B**||||
||0.33–1.65A<br>1–5A|5E1P6<br>5E005||5G1P6<br>5G005|
||4–20A|5E020||5G020|
||**Frame C**<br>0.33–1.65A|5E1P6||5G1P6|
||1–5A|5E005||5G005|
||4–20A|5E020||5G020|
||9–45A|5E045||5G045|
||**Frame D**<br>9–45A|5E045||5G045|
||20–100A|5E100||5G100|
||**Frame F, G**<br>20–100A|5E100||5G100|
||**Frame G, H**||||
||35–175A|5E175||5G175|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-38**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Product Selection**
## _**Full Voltage, Non-Reversing Contactors**_
## **Frame B**
## **Three-Pole Contactors, Frame B—UL/CSA Ratings**
|**UL General Purpose**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|
|**Ampere Rating**<br>**115V**<br>**200V**<br>20<br>1/4<br>3/4<br>~~LL~~|||**230V**<br>1|**200V**<br>1-1/2|**230V**<br>2|**460V**<br>3|**575V**<br>5|**Contacts**<br>1NO|**Catalog Number**12<br>**XTCE007B10_**|
|20|1/4|3/4|1|1-1/2|2|3|5|1NC|**XTCE007B01_**|
|20|1/2|1|1-1/2|3|3|5|7-1/2|1NO|**XTCE009B10_**|
|20|1/2|1|1-1/2|3|3|5|7-1/2|1NC|**XTCE009B01_**|
|20|1|2|2|3|3|103|10|1NO|**XTCE012B10_**|
|20|1|2|2|3|3|103|10|1NC|**XTCE012B01_**|
|20<br>20|1<br>1|2<br>2|3<br>3|5<br>5|5<br>5|103<br>103|10<br>10|1NO<br>1NC|**XTCE015B10_**<br>**XTCE015B01_**|
## **Three-Pole Contactors, Frame B—IEC Ratings**
|**AC-3**|**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|
|**Ie (A)**|**Ie = Ith (A)**|**220/230V**|**380/400V**|**415V**|**660/690V**|**Contacts**|**Catalog Number**12|
|7|22|2.2|3|4|3.5|1NO|**XTCE007B10_**|
|7|22|2.2|3|4|3.5|1NC|**XTCE007B01_**|
|9<br>9|22<br>22|2.5<br>2.5|4<br>4|5.5<br>5.5|4.5<br>4.5|1NO<br>1NC|**XTCE009B10_**<br>**XTCE009B01_**|
|12|22|3.5|5.5|7|6.5|1NO|**XTCE012B10_**|
|12|22|3.5|5.5|7|6.5|1NC|**XTCE012B01_**|
|15.5|22|4|7.5|8|7|1NO|**XTCE015B10_**|
|15.5|22|4|7.5|8|7|1NC|**XTCE015B01_**|
## _**Notes**_
The 7–32A XTCE contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact module as well as within the auxiliary contact modules.
DC operated contactors (Frames B–G, 7–150A) have a built-in suppressor circuit.
- 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
- 2 For spring cage terminals, insert **C** after the fourth digit of the catalog number. Example: XTCE **C** 007B10A. For 7–12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage. For 18–32A XTCEC contactors, the auxiliary and coil terminals are spring cage. For 40–150A XTCEC contactors, the coil terminals only are spring cage.
- 3 For electrical life contactor application data. See **Page V5-T1-45** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-39**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## **Frame C**
## **Three-Pole Contactors, Frame C—UL/CSA Ratings**
|||**UL General Purpose**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|
|eee.<br>re<br>| <br>=<br>2<br>|<br>ae<br>——| *<br>“eet! <br>eae||**Ampere Rating**<br>**Contacts**<br>**Catalog Number**12<br>**115V**<br>**200V**<br>**230V**<br>**200V**<br>**230V**<br>**460V**<br>**575V**<br>40<br>2<br>2<br>3<br>5<br>5<br>10<br>15<br>1NO<br>**XTCE018C10_**<br>40<br>2<br>2<br>3<br>5<br>5<br>10<br>15<br>1NC<br>**XTCE018C01_**<br>40<br>2<br>3<br>5<br>7-1/2<br>10<br>15<br>20<br>1NO<br>**XTCE025C10_**<br> ~~De~~<br> ~~ooo~~||||||||
|||40|2<br>3|5|7-1/2<br>10|15|20|1NC|**XTCE025C01_**|
|||40|3<br>5|5|10<br>10|20|25|1NO|**XTCE032C10_**|
|||40|3<br>5|5|10<br>10|20|25|1NC|**XTCE032C01_**|
|||40|3<br>5|5|10<br>10|25|30|1NO|**XTCE038C10_**|
|||40|3<br>5|5|10<br>10|25|30|1NC|**XTCE038C01_**|
## **Three-Pole Contactors, Frame C—IEC Ratings**
|**AC-3**<br>**Ie (A)**<br>**AC-1 (40°C)**<br>**Ie = Ith (A)**<br>18<br>40<br>18<br>40<br>~~—~~<br>~~SSS~~|**AC-3**<br>**Ie (A)**<br>**AC-1 (40°C)**<br>**Ie = Ith (A)**<br>18<br>40<br>18<br>40<br>~~—~~<br>~~SSS~~|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**<br>5<br>7.5<br>10<br>11<br>5<br>7.5<br>10<br>11<br>~~SSS~~|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**<br>5<br>7.5<br>10<br>11<br>5<br>7.5<br>10<br>11<br>~~SSS~~|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**<br>5<br>7.5<br>10<br>11<br>5<br>7.5<br>10<br>11<br>~~SSS~~|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**<br>5<br>7.5<br>10<br>11<br>5<br>7.5<br>10<br>11<br>~~SSS~~|**Auxiliary**<br>**Contacts**<br>1NO<br>1NC<br>~~SSS~~|**Screw Terminal**<br>**Catalog Number**12<br>**XTCE018C10_**<br>**XTCE018C01_**<br>~~SSS~~|
|---|---|---|---|---|---|---|---|
|25<br>25|45<br>45|7.5<br>7.5|11<br>11|14.5<br>14.5|14<br>14|1NO<br>1NC|**XTCE025C10_**<br>**XTCE025C01_**|
|32|45|10|15|18|17|1NO|**XTCE032C10_**|
|32|45|10|15|18|17|1NC|**XTCE032C01_**|
|38|45|11|18.5|18.5|21|1NO|**XTCE038C10_**|
|38|45|11|18.5|18.5|21|1NC|**XTCE038C01_**|
## **Frame D**
## **Three-Pole Contactors, Frame D—UL/CSA Ratings**
|**UL General Purpose**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|---|
|**Ampere Rating**|**115V**|**200V**|**230V**|**200V**|**230V**||**460V**|**575V**|**Contacts**|**Catalog Number**12|
|63<br>3<br>5<br>7-1/2<br>10<br>15<br>30<br>40<br>—<br>**XTCE040D00_**<br>63<br>3<br>5<br>7-1/2<br>10<br>15<br>30<br>40<br>1NO-1NC<br>**XTCE040DS1_**<br>80<br>3<br>7-1/2<br>10<br>15<br>20<br>40<br>50<br>—<br>**XTCE050D00_**<br>~~a~~|||||||||||
|80<br>88<br>~~0~~|3<br>5|7-1/2<br>10|10<br>15<br>15<br>20<br>~~eee~~||20<br>25<br>~~eee~~|~~sss ss~~|40<br>50<br>50<br>60<br>~~sssss...~~||1NO-1NC<br>**XTCE050DS1_**<br>—<br>**XTCE065D00_**<br>~~QQXQ__c_=~~||
|88<br>88|5<br>5|10<br>10|15<br>15|20<br>20|25<br>25||50<br>50|60<br>60|1NO-1NC<br>—|**XTCE065DS1_**<br>**XTCE072D00_**|
|88|5|10|15|20|25||50|60|1NO-1NC|**XTCE072DS1_**|
## **Three-Pole Contactors, Frame D—IEC Ratings**
|**AC-3**|**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|
|**Ie (A)**<br>~~=~~|**Ie = Ith (A)**<br>~~=~~|**220/230V**<br>~~=~~|**380/400V**<br>~~=~~|**415V**<br>~~=~~|**660/690V**<br>~~=~~|**Contacts**<br>~~=~~|**Catalog Number**12<br>~~=~~|
|40|60|12.5|18.5|24|23|—|**XTCE040D00_**|
|40|60|12.5|18.5|24|23|1NO-1NC|**XTCE040DS1_**|
|50|80|15.5|22|30|30|—|**XTCE050D00_**|
|50|80|15.5|22|30|30|1NO-1NC|**XTCE050DS1_**|
|65|98|20|30|39|35|—|**XTCE065D00_**|
|65|98|20|30|39|35|1NO-1NC|**XTCE065DS1_**|
|72<br>72|98<br>98|22<br>22|37<br>37|41<br>41|35<br>35|—<br>1NO-1NC|**XTCE072D00_**<br>**XTCE072DS1_**|
## _**Notes**_
The 7–32A XTCE contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact module as well as within the auxiliary contact modules.
The 40–65A XTCE contactors have positively driven contacts within the auxiliary contact module. Six auxiliary contacts are possible with a combination of side-mounted and front-mount auxiliary contacts.
DC operated contactors (Frames B–G, 7–150A) have a built-in suppressor circuit.
- 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
- 2 For spring cage terminals, insert **C** after the fourth digit of the catalog number. Example: XTCE **C** 007B10A. For 7–12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage. For 18–32A XTCEC contactors, the auxiliary and coil terminals are spring cage. For 40–150A XTCEC contactors, the coil terminals only are spring cage.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-40**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame F**
## **Three-Pole Contactors, Frame F—UL/CSA Ratings**
||**UL General Purpose**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|---|
||**Ampere Rating**|**115V**|**200V**|**230V**|**200V**|**230V**|**460V**|**575V**|**Contacts**|**Catalog Number**12|
||125|7-1/2|15|15|25|30|60|75|—|**XTCE080F00_**|
||125|7-1/2|15|15|25|30|60|75|1NO-1NC|**XTCE080FS1_**|
||125|7-1/2|15|15|25|40|75|100|—|**XTCE095F00_**|
|125<br>7-1/2<br>15<br>15<br>25<br>40<br>75<br>100<br>1NO-1NC<br>**XTCE095FS1_**<br>~~2~~|||||||||||
## **Three-Pole Contactors, Frame F—IEC Ratings**
|**AC-3**|**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|
|**Ie (A)**<br>80|**Ie = Ith (A)**<br>110|**220/230V**<br>25|**380/400V**<br>37|**415V**<br>48|**660/690V**<br>63|**Contacts**<br>—|**Catalog Number**12<br>**XTCE080F00_**|
|80|110|25|37|48|63|1NO-1NC|**XTCE080FS1_**|
|95|130|30|45|57|75|—|**XTCE095F00_**|
|95|130|30|45|57|75|1NO-1NC|**XTCE095FS1_**|
## **Frame G**
## **Three-Pole Contactors, Frame G—UL/CSA Ratings**
|**UL General Purpose**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**||**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**<br>**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|
|**Ampere Rating**<br>160|**115V**<br>10|**200V**<br>25|**230V**<br>25||**200V**<br>40|**230V**<br>50|**460V**<br>100|**575V**<br>100|**Contacts**<br>**Catalog Number**12<br>—<br>**XTCE115G00_**|
|160<br>180|10<br>10|25<br>25|25<br>30||40<br>40|50<br>60|100<br>100<br>1NO-1NC<br>**XTCE115GS1_**<br>125<br>125<br>—<br>**XTCE150G00_**<br>~~Se~~|||
|180|10<br>n nnn|25<br> ttnsSnns|30<br> nnntN|NNN|40<br>NUN|60<br>125<br> ~~NNN~~||125|1NO-1NC<br>**XTCE150GS1_**<br>~~0000000000~~|
|180<br>180|10<br>10|25<br>25|30<br>30||40<br>40|60<br>60|125<br>125|125<br>125|—<br>**XTCE170G00_**<br>1NO-1NC<br>**XTCE170GS1_**|
## **Three-Pole Contactors, Frame G—IEC Ratings**
|**AC-3**|**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|
|**Ie (A)**|**Ie = Ith (A)**|**220/230V**|**380/400V**|**415V**|**660/690V**|**Contacts**|**Catalog Number**12|
|115|160|37|55|70|90|—|**XTCE115G00_**|
|115|160|37|55|70|90|1NO-1NC|**XTCE115GS1_**|
|150|190|48|75|91|96|—|**XTCE150G00_**|
|150|190|48|75|91|96|1NO-1NC|**XTCE150GS1_**|
|170<br>170|225<br>225|52<br>52|90<br>90|100<br>100|96<br>96|—<br>1NO-1NC|**XTCE170G00_**<br>**XTCE170GS1_**|
## _**Notes**_
The 40–65A XTCE contactors have positively driven contacts within the auxiliary contact module. Six auxiliary contacts are possible with a combination of side-mounted and front-mount auxiliary contacts.
DC operated contactors (Frames B–G, 7–150A) have a built-in suppressor circuit.
- 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
- 2 For spring cage terminals, insert **C** after the fourth digit of the catalog number. Example: XTCE **C** 007B10A. For 7–12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage. For 18–32A XTCEC contactors, the auxiliary and coil terminals are spring cage. For 40–150A XTCEC contactors, the coil terminals only are spring cage.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-41**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Frame H**
## **Three-Pole Contactors, Frame H (Electronic Coil)—UL/CSA Ratings**
|**UL General Purpose**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**|**Catalog**|
|---|---|---|---|---|---|---|
|**Ampere Rating**<br>250|**200V**<br>50|**240V**<br>60|**480V**<br>125|**600V**<br>150|**Contacts**<br>2NO-2NC|**Number**123<br>**XTCE185H22_**|
|250|60|75|150|200|2NO-2NC|**XTCE225H22_**|
## **Three-Pole Contactors, Frame H (Electronic Coil)—IEC Ratings**
## **Frame L**
||**AC-3**|**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Catalog**|
|---|---|---|---|---|---|---|---|
||**Ie (A)**|**Ie = Ith (A)**|**220/230V**<br>**380/400V**|**660/690V**4|**1000V**4|**Contacts**|**Number**123|
||185|337|55<br>90|140|108|2NO-2NC|**XTCE185H22_**|
|225||386|70<br>110|215|108|2NO-2NC|**XTCE225H22_**|
||**Three-Pole Contactors, Frame L—UL/CSA Ratings**|||**Three-Pole Contactors, Frame L—UL/CSA Ratings**||||
||**UL General Purpose**<br>**Ampere Rating**||**Three-Phase hp Ratings**<br>**200V**<br>**230V**|**460V**|**575V**|**Auxiliary**<br>**Contacts**|**Catalog**<br>**Number**12|
||**Standard Coil (110/120V, 230/240 Vac Coil Only)**<br>300<br>75<br>100|||200|250|2NO-2NC|**XTCS250L22_**|
||350<br>**Electronic Coil**||100<br>125|250|300|2NO-2NC|**XTCS300L22_**|
||300||75<br>100|200|250|2NO-2NC|**XTCE250L22_**|
||350||100<br>125|250|300|2NO-2NC|**XTCE300L22_**|
||**Three-Pole Contactors, Frame L—IEC Ratings**|||||||
||**AC-3**|**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**||**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Catalog**|
||**Ie (A)**|**Ie = Ith (A)**|**220/230V**<br>**380/400V**|**660/690V**4|**1000V**4|**Contacts**|**Number**12|
||**Standard Coil (110/120V, 230/240 Vac Coil Only)**|||||||
||250|429|75<br>132|240|108|2NO-2NC|**XTCS250L22_**|
||300|490|90<br>160|195|132|2NO-2NC|**XTCS300L22_**|
||**Electronic Coil**<br>250|429|75<br>132|240|108|2NO-2NC|**XTCE250L22_**|
||300|490|90<br>160|195|132|2NO-2NC|**XTCE300L22_**|
## _**Notes**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** . Terminals not included. See **Page V5-T1-75** for terminal accessories.
2 Does not include lugs.
3 Add “-S730” to the end of the catalog number after the coil voltage to configure as extended H frame model. Extended H frame will align with L frame contactor for interlocks and mounting height. Consult Vista/Eaton care for availability of extended base models
4 For 185–500A contactors at 660/690V or 1000V: Do not reverse directly.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-42**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Three-Pole Contactors, Frame M—UL/CSA Ratings**
|**Frame M**|**Three-Pole Contactors, Frame M—UL/CSA Ratings**<br>**UL General Purpose**|**Three-Pole Contactors, Frame M—UL/CSA Ratings**<br>**Three-Phase hp Ratings**|**Three-Pole Contactors, Frame M—UL/CSA Ratings**|**Three-Pole Contactors, Frame M—UL/CSA Ratings**||**Auxiliary**|**Catalog**|
|---|---|---|---|---|---|---|---|
||**Ampere Rating**<br>**Standard Coil (110/120V, 230/240 Vac Coil Only)**|**200V**<br>**230V**<br>**Standard Coil (110/120V, 230/240 Vac Coil Only)**||**460V**|**575V**|**Contacts**|**Number**12|
||450|125<br>150||300|400|2NO-2NC|**XTCS400M22_**|
||550|150<br>200||400|500|2NO-2NC|**XTCS500M22_**|
||**Electronic Coil**|||||||
||450|125<br>150||300|400|2NO-2NC|**XTCE400M22_**|
||550|150<br>200||400|500|2NO-2NC|**XTCE500M22_**|
||**Three-Pole Contactors, Frame M—IEC Ratings**|||||||
||**AC-3**<br>**AC-1 (40°C)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|||**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**|**Auxiliary**|**Catalog**|
||**Ie (A)**<br>**Ie = Ith (A)**|**220/230V**<br>**380/400V**|**415V**|**660/690V**3|**1000V**3|**Contacts**|**Number**12|
||**Standard Coil (110/120V, 230/240 Vac Coil Only)**|**Standard Coil (110/120V, 230/240 Vac Coil Only)**||||||
||400<br>612|125<br>200|240|344|132|2NO-2NC|**XTCS400M22_**|
||500<br>800<br>**Electronic Coil**|155<br>250|300|344|132|2NO-2NC|**XTCS500M22_**|
||400<br>612<br>500<br>800|125<br>200<br>155<br>250|240<br>300|344<br>344|132<br>132|2NO-2NC<br>2NO-2NC|**XTCE400M22_**<br>**XTCE500M22_**|
## _**Notes**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** . Terminals not included. See **Page V5-T1-75** for terminal accessories.
- 2 Does not include lugs.
- 3 For 185–500A contactors at 660/690V or 1000V: Do not reverse directly.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-43**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Frame N**
## **Three-Pole Contactors, Frame N (Electronic Coil)—UL/CSA Ratings**
|**UL General Purpose**<br>**Ampere Rating**|**Three-Phase hp Ratings**<br>**200V**<br>**230V**|**Three-Phase hp Ratings**<br>**200V**<br>**230V**|**460V**|**575V**|**Auxiliary**<br>**Contacts**|**Catalog Number**12|
|---|---|---|---|---|---|---|
|630<br>700|200<br>200|200<br>250|400<br>500|600<br>600|2NO-2NC<br>2NO-2NC|**XTCE580N22_**3<br>**XTCE650N22_**3|
|800<br>850<br>~~i~~|250<br>290|300<br>350|600<br>700|700<br>860|2NO-2NC<br>2NO-2NC|**XTCE750N22_**3<br>**XTCE820N22_**3|
|1100|350|420|850|980|2NO-2NC|**XTCEC10N22_**3|
## **Three-Pole Contactors, Frame N (Electronic Coil)—IEC Ratings**
## **Frame P**
|**AC-3**<br>**Ie (A)**<br>**AC-1 (40°C)**<br>**Ie = Ith (A)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**1000V**4|**Auxiliary**<br>**Contacts**|**Catalog Number**12|
|---|---|---|---|---|---|---|
|580<br>980|185<br>315|348|560|600|2NO-2NC|**XTCE580N22_**3|
|650<br>1041|205<br>355|390|630|600|2NO-2NC|**XTCE650N22_**3|
|750<br>1102|240<br>400|455|720|800|2NO-2NC|**XTCE750N22_**3|
|820<br>1225<br>1000<br>1225|260<br>450<br>315<br>560|500<br>610|750<br>1000|800<br>1000|2NO-2NC<br>2NO-2NC|**XTCE820N22_**3<br>**XTCEC10N22_**3|
|**Three-Pole Contactors, Frame P (Electronic Coil)—UL/CSA Ratings**<br>**UL General Purpose**<br>**Ampere Rating**<br>**Three-Phase hp Ratings**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|||||**Auxiliary**<br>**Contacts**|**Catalog Number**12|
|1400|—<br>—||—|—|2NO-2NC|**XTCEC14P22_**3|
## **Three-Pole Contactors, Frame P (Electronic Coil)—IEC Ratings**
## **Frame R**
|**AC-3**<br>**Ie (A)**<br>**AC-1 (40°C)**<br>**Ie = Ith (A)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**1000V**4|**Auxiliary**<br>**Contacts**|**Catalog Number**12|
|---|---|---|---|---|---|---|
|—<br>1714|—<br>—|—|—|—|2NO-2NC|**XTCEC14P22_**3|
|**Three-Pole Contactors, Frame R (Electronic Coil)—UL/CSA Ratings**|||||||
|**UL General Purpose**<br>**Ampere Rating**|**Three-Phase hp Ratings**<br>**200V**<br>**230V**||**460V**|**575V**|**Auxiliary**<br>**Contacts**|**Catalog Number**12|
|1600|560<br>640||1200|1300|2NO-2NC|**XTCEC16R22_**3|
|2000|—<br>—||—|—|2NO-2NC|**XTCEC20R22_**3|
## **Three-Pole Contactors, Frame R (Electronic Coil)—IEC Ratings**
|**AC-3**<br>**Ie (A)**|**AC-1 (40°C)**<br>**Ie = Ith (A)**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**220/230V**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**380/400V**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**415V**|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**660/690V**4|**Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz**<br>**1000V**4|**Auxiliary**<br>**Contacts**|**Catalog Number**12|
|---|---|---|---|---|---|---|---|---|
|1600|2200|500|900|900|1600|1700|2NO-2NC|**XTCEC16R22_**3|
|—|2450|—|—|—|—|—|2NO-2NC|**XTCEC20R22_**3|
## _**Notes**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** . Terminals not included. See **Page V5-T1-75** for terminal accessories.
- 2 Does not include lugs.
- 3 When operating the 580–2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test—see Pub51204, Pub51209.
- 4 For 185–500A contactors at 660/690V or 1000V: do not reverse directly.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-44**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**Contactor Application Data**[12]
|**Catalog**<br>**Electrical Life (Operations)**<br>**for 10 hp, 480V (14.2A)**|
|---|
|**Prefix**<br>**Applications**<br>XTCE012B<br>1 million<br>XTCE015B<br>1.2 million<br>XTCE018C<br>2 million<br>~~ES~~<br>~~oo~~<br>~~Se~~|
**Full Voltage Non-Reversing Three-Pole Contactors— Contact Sequence (Circuit Symbols)—Standard Offering**
|**Contactor**<br>**Frame**|**Auxiliary**<br>**Contacts**|**Contact Sequence**|
|---|---|---|
|B–C<br>B–C|1NO<br>1NC|2<br>3 5<br>4 6<br>A1<br>A2<br>1<br>13<br>14<br>2<br>3 5<br>4 6<br>A1<br>A2<br>1<br>21<br>22<br>|<br>~~yyy~~<br>Ito<br>~~oy~~|
|D–G|—|2<br>3 5<br>4 6<br>A1<br>A2<br>1<br>Ito<br>~~yy~~|
||||
|L–R|2NO-2NC||
## **Four-Pole Contactors with Screw Terminals—Maximum UL/CSA Motor Ratings**
|**Single-Phase hp Ratings**<br>**115V**|**Single-Phase hp Ratings**<br>**230V**|**Three-Phase hp Ratings**<br>**200V**|**Three-Phase hp Ratings**<br>**230V**|**460V**|**575V**|**Auxiliary**<br>**Contacts**|**Contact**<br>**Sequence**||**Catalog Number**3|
|---|---|---|---|---|---|---|---|---|---|
|1<br>—<br>—|2<br>—<br>—|3<br>7.5<br>7.5|3<br>7.5<br>10|10<br>10<br>15|10<br>15<br>20|—<br>1NO<br>1NO<br>~~TT~~ila|ANT)<br>3)8)7<br>Ciaalele<br>AbpU pays pry<br>ila||**XTCF020B00_**<br>**XTCF032C10_**<br>**XTCF045C10_**<br>~~—_—~~|
|—|—|10|15|30|40|—|Ati1 38;7||**XTCF063D00_**|
|—|—|15|20|40|50|—|||**XTCF080D00_**|
|—<br>—|—<br>—|25<br>25|30<br>40|60<br>75|75<br>100|—<br>—|AY1,<br>3)5)7||**XTCF125G00_**<br>**XTCF160G00_**|
|—|—|40|50|100|125|—|||**XTCF200G00_**|
## **Four-Pole Contactors with Screw Terminals—Maximum IEC Ratings**
|**Four-Pole Contactors with Screw Terminals—Maximum IEC Ratings**|||
|---|---|---|
|**AC-3**<br>**AC-1**<br>**Three-Phase hp Ratings**<br>**Auxiliary**|**Contact**||
|**Ie (A)**<br>**(40°C)**<br>**Contacts**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Sequence**|**Catalog Number**3|
|12<br>22<br>3<br>3<br>10<br>10<br>—<br>12<br>22<br>3.5<br>5.5<br>7<br>6.5<br>—|Att) 315)7<br>Caraalele<br>Att) 315)7<br>Caraalele|**XTCF020B00_**<br>**XTCF020B00_**|
|18<br>32<br>5<br>7.5<br>10<br>11<br>1NO<br>25<br>45<br>7.5<br>11<br>14.5<br>14<br>1NO<br>~~mijn ~~|ADpl pays<br>prqy<br> EA<br>A Velalie|**XTCF032C10_**<br>**XTCF045C10_**<br>~~—~~|
|40<br>63<br>12.5<br>18.5<br>24<br>23<br>—<br>50<br>80<br>15.5<br>22<br>30<br>30<br>—<br>80<br>125<br>25<br>37<br>48<br>63<br>—<br>95<br>160<br>30<br>45<br>57<br>75<br>—<br>115<br>200<br>37<br>55<br>70<br>90<br>—<br>~~—~ ~~|At\1;<br>3,5;7<br>Caaalele<br>AU.38i7<br> Cavrele|**XTCF063D00_**<br>**XTCF080D00_**<br>**XTCF125G00_**<br>**XTCF160G00_**<br>**XTCF200G00_**<br>~~OO~~|
## _**Notes**_
> 1 See **Page V5-T1-111** for electrical life curves.
> 2 AC and DC operated contactors have a built-in suppressor circuit (Frames L–R, 185–2000A).
> 3 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-45**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Switching of DC Currents**[1]
|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|**Switching of DC Currents**1|
|---|---|---|---|---|---|---|---|---|
|**escription**<br>**Single-Pole**<br>**Two-Pole**|||||||||
|TCF020B–XTCF200G<br>>60 Vdc|||||||||
||||||||||
||||||||||
## **Controlling XTCS and XTCE Contactors Frames L–R (185–2000A)**
**==> picture [392 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTCS250L–XTCS500M,<br>Description XTCE_H XTCEC16R, XTCEC20R XTCE250L–XTCEC14P<br>Conventional (+) L1 (+) L1 (+) L1<br>A1/A2 are applied to voltage in the usual manner. (–) N (–) N (–) N<br>b b b<br>A10 A2 A10 A2 A10 A2<br>A11 A1 A11 A1 A11 A1<br>A3 TY A3 A3<br>A4 TX A4 A4<br>Direct from the PLC — (+) L1 (+) L1<br>A 24V output from the PLC can be connected directly to (–) N (–) N<br>connections A3/A4. A10 A2 b A10 A2 b<br>A11 A1 A11 A1<br>TY A3 A3<br>TX A4 A4<br>24V 24V<br>GND GND<br>From Low-Consumption Command Devices — (+) L1 (+) L1<br>Command devices, which can only be subject to minimal loads (–) N (–) N<br>such as circuit board relays, control circuit devices or position switches can be connected directly to A10/A11. c A10A11 A2A1 b c A10A11 A2A1 b<br>TY A3 A3<br>TX A4 A4<br>**----- End of picture text -----**<br>
## _**Notes**_
> 1 When necessary, cable to be supplied by customer.
- 2 Standstill in an emergency (emergency-stop).
- 3 Command device connection.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-46**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Full Voltage, Reversing Contactors**_
## **Frame B**
## **Contactors with Screw Terminals, Frame B—Maximum UL/CSA Ratings**
|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**||
|---|---|---|---|---|---|---|---|---|---|---|
|**115V**|**230V**|**200V**|**230V**|**460V**|**575V**|**K1M**||**K2M**||**Catalog Number**1|
|1/4|1|1-1/2|2|3|5||63||63|**XTCR007B21_**|
||||||||64||64||
|1/2|1-1/2|3|3|5|7-1/2||63||63|**XTCR009B21_**|
||||||||64||64||
|1/2|2|3|3|10|10||64<br>63||64<br>63|**XTCR012B21_**|
## **Contactors with Screw Terminals, Frame B—Maximum IEC Ratings**
|**AC-3**|**Three-Phase Motors 50–60 Hz**|**Three-Phase Motors 50–60 Hz**|||**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**||
|---|---|---|---|---|---|---|---|---|---|
|**Ie (A)**|**220/230V**|**380/400V**|**415V**|**660/690V**|**K1M**||**K2M**||**Catalog Number**1|
|7|2.2|3|4|3.5||63||63|**XTCR007B21_**|
|||||||64||64||
|9|2.5|4|5.5|4.5||64<br>63||64<br>63|**XTCR009B21_**|
|12|3.5|5.5|7|6.5||63||63|**XTCR012B21_**|
|||||||64||64||
## **Frame C**
## **Contactors with Screw Terminals, Frame C—Maximum UL/CSA Ratings**
|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**||
|---|---|---|---|---|---|---|---|---|---|---|
|**115V**|**230V**|**200V**|**230V**|**460V**|**575V**|**K1M**||**K2M**||**Catalog Number**1|
|2|3|5|5|10|15||64<br>63||64<br>63|**XTCR018C21_**|
|2|5|7-1/2|10|15|20||64<br>63||64<br>63|**XTCR025C21_**|
|3|5|10|10|20|25||63||63|**XTCR032C21_**|
||||||||64||64||
## **Contactors with Screw Terminals, Frame C—Maximum IEC Ratings**
|**AC-3**<br>**Ie (A)**|**Three-Phase Motors 50–60 Hz**<br>**220/230V**|**Three-Phase Motors 50–60 Hz**<br>**380/400V**|**415V**|**660/690V**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Catalog Number**1|
|---|---|---|---|---|---|---|---|---|---|
|18|5|7.5|8|11||64<br>63||64<br>63|**XTCR018C21_**|
|25|7.5|11|14.5|14||63||63|**XTCR025C21_**|
|||||||64||64||
|32|10|15|18|17||63||63|**XTCR032C21_**|
|||||||64||64||
## _**Note**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-47**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Frame D**
## **Frame F**
## **Contactors with Screw Terminals, Frame D—Maximum UL/CSA Ratings**
||**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**||**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**||
|---|---|---|---|---|---|---|---|
||**115V**<br>**230V**|**200V**|**230V**<br>**460V**|**575V**|**K1M**|**K2M**|**Catalog Number**1|
||3<br>7-1/2|10|15<br>30|40|—|—|**XTCR040D11_**|
|3<br>10<br>15<br>20<br>40<br>50<br>—<br>—<br>**XTCR050D11_**<br>~~a~~||||||||
||5<br>15|20|25<br>50|60|—|—|**XTCR065D11_**|
||**Contactors with Screw Terminals, Frame D—Maximum IEC Ratings**|||||||
||**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**220/230V**|**Three-Phase Motors 50–60 Hz**<br>**380/400V**|**415V**|**660/690V**|**Spare Auxiliary Contacts**<br>**K1M**|**Spare Auxiliary Contacts**<br>**K2M**|**Catalog Number**1|
||40<br>12.5|18.5|24|23|—|—|**XTCR040D11_**|
||50<br>15.5|22|30|30|—|—|**XTCR050D11_**|
||65<br>20|30|39|35|—|—|**XTCR065D11_**|
||**Contactors with Screw Terminals, Frame F—Maximum UL/CSA Ratings**|||||||
||**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**||**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**||
||**115V**<br>**230V**|**200V**|**230V**<br>**460V**|**575V**|**K1M**|**K2M**|**Catalog Number**1|
|~~a~~|7-1/2<br>15<br>~~a~~|25<br>~~a~~|30<br>60<br>~~a~~|75<br>~~a~~|—<br>~~a~~|—<br>~~a~~|**XTCR080F11_**<br>~~a~~|
||7-1/2<br>15|25|40<br>75|100|—|—|**XTCR095F11_**|
## **Contactors with Screw Terminals, Frame F—Maximum IEC Ratings**
|**AC-3**<br>**Ie (A)**|**Three-Phase Motors 50–60 Hz**<br>**220/230V**|**Three-Phase Motors 50–60 Hz**<br>**380/400V**|**415V**|**660/690V**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Spare Auxiliary Contacts**<br>**K1M**<br>**K2M**|**Catalog Number**1|
|---|---|---|---|---|---|---|---|
|80|25|37|48|63|—|—|**XTCR080F11_**|
|95|30|45|57|75|—|—|**XTCR095F11_**|
## **Frame G**
## **Contactors with Screw Terminals, Frame G—Maximum UL/CSA Ratings**
|**Single-Phase hp Ratings**|**Single-Phase hp Ratings**|**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Spare Auxiliary Contacts**||
|---|---|---|---|---|---|---|---|
|**115V**|**230V**|**200V**|**230V**|**460V**|**575V**|**K1M**<br>**K2M**|**Catalog Number**1|
|10<br>15<br>~~ee~~|25<br>30<br>~~ee~~|40<br>40<br>~~ee~~|50<br>60<br>~~ee~~|100<br>100<br>~~ee~~|100<br>100<br>~~ee~~|—<br>—<br>—<br>—<br>~~ee~~|**XTCR115G11_**<br>**XTCR150G11_**<br>~~ee~~|
## **Contactors with Screw Terminals, Frame G—Maximum IEC Ratings**
|**AC-3**|**Three-Phase Motors 50–60 Hz**|**Three-Phase Motors 50–60 Hz**|||**Spare Auxiliary Contacts**|**Spare Auxiliary Contacts**||
|---|---|---|---|---|---|---|---|
|**Ie (A)**|**220/230V**|**380/400V**|**415V**|**660/690V**|**K1M**|**K2M**|**Catalog Number**1|
|115|37|55|70|90|—|—|**XTCR115G11_**|
|150|48|75|91|96|—|—|**XTCR150G11_**|
## _**Note**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-48**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTCR Reversing Contactor Components**
|**Quantity**|**Frame**|**B**|**C**|**D**|**F**|**G**|
|---|---|---|---|---|---|---|
|2|Contactor|XTCE…B01_|XTCE…C01_|XTCE…D00_|XTCE…F00_|XTCE…G00_|
|2|Auxiliary contact|XTCEXFAC20|XTCEXFAC20|XTCEXFBG11|XTCEXFBG11|XTCEXFBG11|
|1|Mechanical interlock|XTCEXMLB|XTCEXMLC|XTCEXMLD|XTCEXMLG|XTCEXMLG|
|1|Reversing link kit|XTCEXRLB|XTCEXRLC|XTCEXRLD|XTCEXRLG|XTCEXRLG|
## **Magnet Coil Suffix**
|**Coil Voltage**<br>**Suffix Code**<br>**Frames A–B**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24 Vdc<br>**TD**<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>120 Vdc<br>**AD**<br>220 Vdc<br>**BD**<br>12 Vdc<br>**RD**<br>48 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**<br>**Frames C–F**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD**<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>48–60 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**<br>**Frame G**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD**<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>42–48V 50/60 Hz<br>**W**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>48–60 Vdc<br>**WD**<br>**Frame H**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>24V 50/60Hz<br>**T**<br>42–48V 50/60Hz<br>**W**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>24–27 Vdc<br>**TD**<br>48–60 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**|
|---|---|---|---|
||||**Frames L–N**|
||||110–250 Vdc 40–60 Hz<br>**A**|
||||250–500V 40–60 Hz<br>**C**|
||||48–110 Vdc 40–60 Hz<br>**Y**|
||||24–48 Vdc<br>**TD** 1|
||||**Frames L–M, S-Series**|
||||110–120V 50/60 Hz<br>**A**|
||||220–240V 50/60 Hz<br>**B**|
||||**Frames P–R**|
||||230–250 Vdc 50–60 Hz<br>**B**|
|||||
## _**Note**_
> 1 Frames L–M only.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-49**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**Full Voltage, Non-Reversing Starters, with Bimetallic or Electronic Overload**_
## **Frame B**
## **Three-Pole Starters, Frame B—Maximum UL/CSA Ratings**[1]
|**Single-Phase hp Ratings**<br>**Three-Phase hp Ratings**<br>**Auxiliary**<br>**Contacts**<br>**Catalog Number**23<br>**115V**<br>**230V**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|
|---|
|1/4<br>1<br>1-1/2<br>2<br>3<br>5<br>1NO<br>**XTAE007B10_ _**<br>1/4<br>1<br>1-1/2<br>2<br>3<br>5<br>1NC<br>**XTAE007B01_ _**<br> ~~ee~~|
|1/2<br>1-1/2<br>3<br>3<br>5<br>7-1/2<br>1NO<br>**XTAE009B10_ _**<br>1/2<br>1-1/2<br>3<br>3<br>5<br>7-1/2<br>1NC<br>**XTAE009B01_ _**<br> ~~ee~~<br>~~OO~~|
|1<br>2<br>3<br>3<br>104<br>10<br>1NO<br>**XTAE012B10_ _**<br>1<br>2<br>3<br>3<br>104<br>10<br>1NC<br>**XTAE012B01_ _**|
|1<br>3<br>5<br>5<br>104<br>10<br>1NO<br>**XTAE015B10_ _**|
|1<br>3<br>5<br>5<br>104<br>10<br>1NC<br>**XTAE015B01_ _**|
## **Three-Pole Starters, Frame B—Maximum IEC Ratings**[1]
|**AC-3**<br>**Ie (A)**<br>**AC-1**<br>7<br>20<br>7<br>20<br>~~————~~<br>~~SSS~~|**AC-3**<br>**Ie (A)**<br>**AC-1**<br>7<br>20<br>7<br>20<br>~~————~~<br>~~SSS~~|**Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>2.2<br>2.2<br>~~SSS~~|**Three-Phase Motors 50–60 Hz**<br>**380/400V**<br>3<br>3<br>~~SSS~~|**415V**<br>4<br>4<br>~~SSS~~|**660/690V**<br>3.5<br>3.5<br>~~SSS~~|**Auxiliary**<br>**Contacts**<br>1NO<br>1NC<br>~~SSS~~|**Catalog Number**23<br>**XTAE007B10_ _**<br>**XTAE007B01_ _**<br>~~SSS~~|
|---|---|---|---|---|---|---|---|
|9|20|2.5|4|5.5|4.5|1NO|**XTAE009B10_ _**|
|9|20|2.5|4|5.5|4.5|1NC|**XTAE009B01_ _**|
|12|20|3.5|5.5|7|6.5|1NO|**XTAE012B10_ _**|
|12|20|3.5|5.5|7|6.5|1NC|**XTAE012B01_ _**|
|15.5|20|4|7.5|8|7|1NO|**XTAE015B10_ _**|
|15.5|20|4|7.5|8|7|1NC|**XTAE015B01_ _**|
## **Frame C**
## **Three-Pole Starters, Frame C—Maximum UL/CSA Ratings**[1]
|**Three-Pole Starters, Frame C—Maximum UL/CSA Ratings**|**Three-Pole Starters, Frame C—Maximum UL/CSA Ratings**[1]||
|---|---|---|
|**Single-Phase hp Ratings**<br>**115V**<br>**230V**|**Three-Phase hp Ratings**<br>**Auxiliary**<br>**Contacts**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Catalog Number**23|
|2<br>3<br>5<br>5<br>104<br>15<br>1NO<br>**XTAE018C10_ _**<br>2<br>3<br>5<br>5<br>104<br>15<br>1NC<br>**XTAE018C01_ _**<br>2<br>5<br>7-1/2<br>7-1/2<br>15<br>20<br>1NO<br>**XTAE025C10_ _**<br> ~~SSS~~<br>~~ee~~|||
|2<br>5|7-1/2<br>7-1/2<br>15<br>20<br>1NC|**XTAE025C01_ _**|
|3<br>5|10<br>10<br>20<br>25<br>1NO|**XTAE032C10_ _**|
|3<br>5|10<br>10<br>20<br>25<br>1NC|**XTAE032C01_ _**|
## **Three-Pole Starters, Frame C—Maximum IEC Ratings**[1]
|**AC-3**<br>**Ie (A)**|**AC-1**|**Three-Phase Motors 50–60 Hz**<br>**220/230V**|**Three-Phase Motors 50–60 Hz**<br>**380/400V**|**415V**|**660/690V**|**Auxiliary**<br>**Contacts**|**Catalog Number**23|
|---|---|---|---|---|---|---|---|
|18<br>35<br>~~————~~<br>~~SSS~~||5<br>~~SSS~~|7.5<br>~~SSS~~|10<br>~~SSS~~|11<br>~~SSS~~|1NO<br>~~SSS~~|**XTAE018C10_ _**<br>~~SSS~~|
|18|35|5|7.5|10|11|1NC|**XTAE018C01_ _**|
|25|40|7.5|11|14.5|14|1NO|**XTAE025C10_ _**|
|25<br>32|40<br>40|7.5<br>10|11<br>15|14.5<br>18|14<br>17|1NC<br>1NO|**XTAE025C01_ _**<br>**XTAE032C10_ _**|
|32|40|10|15|18|17|1NC|**XTAE032C01_ _**|
## _**Notes**_
1 Products shown are with the bimetallic overload relay.
- 2 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
- 3 Underscore (_) indicates overload relay suffix required. See **Page V5-T1-54** .
- 4 For electrical life contactor application data. See **Page V5-T1-53** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-50**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame D**
## **Frame F**
## **Frame G**
## **Three-Pole Starters, Frame D—Maximum UL/CSA Ratings**[1]
||**Single-Phase hp Ratings**<br>**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**||
|---|---|---|---|---|---|---|
||**115V**<br>**230V**<br>**200V**|**230V**|**460V**|**575V**|**Contacts**|**Catalog Number**23|
||3<br>7-1/2<br>10|15|30|40|—|**XTAE040D00_ _**|
||3<br>10<br>15|20|40|50|—|**XTAE050D00_ _**|
||5<br>15<br>20|25|50|60|—|**XTAE065D00_ _**|
||**Three-Pole Starters, Frame D—Maximum IEC Ratings**1||||||
||**AC-3**<br>**Ie (A)**<br>**AC-1**<br>**Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**|**415V**||**660/690V**|**Auxiliary**<br>**Contacts**|**Catalog Number**23|
||40<br>50<br>12.5<br>18.5|24||23|—|**XTAE040D00_ _**|
||50<br>60<br>15.5<br>22|30||30|—|**XTAE050D00_ _**|
||65<br>72<br>20<br>30|39||35|—|**XTAE065D00_ _**|
||**Three-Pole Starters, Frame F—Maximum UL/CSA Ratings**1||||||
||**Single-Phase hp Ratings**<br>**Three-Phase hp Ratings**|**Three-Phase hp Ratings**|||**Auxiliary**||
||**115V**<br>**230V**<br>**200V**|**230V**|**460V**|**575V**|**Contacts**|**Catalog Number**23|
||7-1/2<br>15<br>25|30|60|75|—|**XTAE080F00_ _**|
||7-1/2<br>15<br>25|40|75|100|—|**XTAE095F00_ _**|
||**Three-Pole Starters, Frame F—Maximum IEC Ratings**||**Three-Pole Starters, Frame F—Maximum IEC Ratings**1||||
||**AC-3**<br>**Ie (A)**<br>**AC-1**<br>**Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**|**415V**||**660/690V**|**Auxiliary**<br>**Contacts**|**Catalog Number**23|
||80<br>110<br>25<br>37|48||63|—|**XTAE080F00_ _**|
||95<br>110<br>30<br>45|57||75|—|**XTAE095F00_ _**|
||**Three-Pole Starters, Frame G—Maximum UL/CSA Ratings**1||||||
|**Single-Phase hp Ratings**<br>**Three-Phase hp Ratings**<br>**Auxiliary**<br>**Contacts**<br>**Catalog Number**23<br>**115V**<br>**230V**<br>**200V**<br>**230V**<br>**460V**<br>**575V**<br>10<br>25<br>40<br>50<br>100<br>125<br>—<br>**XTAE115G00_ _**<br>15<br>30<br>40<br>60<br>125<br>125<br>—<br>**XTAE150G00_ _**<br>|~~a~~|||||||
||**Three-Pole Starters, Frame G—Maximum IEC Ratings**1<br>**AC-3**<br>**Three-Phase Motors 50–60 Hz**||||**Auxiliary**||
||**Ie (A)**<br>**AC-1**<br>**220/230V**<br>**380/400V**|**415V**||**660/690V**|**Contacts**|**Catalog Number**23|
||115<br>160<br>37<br>55|70||105|—|**XTAE115G00_ _**|
||150<br>160<br>48<br>75|91||125|—|**XTAE150G00_ _**|
## _**Notes**_
1 Products shown are with the bimetallic overload relay.
- 2 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
- 3 Underscore (_) indicates overload relay suffix required. See **Page V5-T1-54** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-51**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**Full Voltage, Reversing Starters, with Bimetallic or Electronic Overload**_
## **Reversing Starters with Screw Terminals, Frame B—Maximum UL/CSA Ratings**
|**Single-Phase**|**hp Ratings**|**Three-Phase**|**hp Ratings**||||
|---|---|---|---|---|---|---|
|**115V**|**230V**|**200V**|**230V**|**460V**|**575V**|**Catalog Number**12|
|1/4|1|1-1/2|2|3|5|**XTAR007B21_ _**|
|1/2|1-1/2|3|3|5|7-1/2|**XTAR009B21_ _**|
|1|2|3|3|10|10|**XTAR012B21_ _**|
## **Reversing Starters with Screw Terminals, Frame B—Maximum IEC Ratings**
|**AC-3**<br>**Ie (A)**|**Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**|**Three-Phase Motors 50–60 Hz**<br>**220/230V**<br>**380/400V**|**415V**|**660/690V**|**Catalog Number**12|
|---|---|---|---|---|---|
|7<br>9|2.2<br>2.5|3<br>4|4<br>5.5|3.5<br>4.5|**XTAR007B21_ _**<br>**XTAR009B21_ _**|
|12|3.5|5.5|7|6.5|**XTAR012B21_ _**|
## **Reversing Starters with Screw Terminals, Frame C—Maximum UL/CSA Ratings**
|**Single-Phase**|**hp Ratings**|**Three-Phase**|**hp Ratings**||||
|---|---|---|---|---|---|---|
|**115V**|**230V**|**200V**|**230V**|**460V**|**575V**|**Catalog Number**12|
|2|3|5|5|10|15|**XTAR018C21_ _**|
|2<br>3|5<br>5|7-1/2<br>10|7-1/2<br>10|15<br>20|20<br>25|**XTAR025C21_ _**<br>**XTAR032C21_ _**|
## **Reversing Starters with Screw Terminals, Frame C—Maximum IEC Ratings**
|**AC-3**|**Three-Phase Motors 50–60 Hz**|**Three-Phase Motors 50–60 Hz**||||
|---|---|---|---|---|---|
|**Ie (A)**|**220/230V**|**380/400V**|**415V**|**660/690V**|**Catalog Number**12|
|18|5|7.5|8|11|**XTAR018C21_ _**|
|25|7.5|11|14.5|14|**XTAR025C21_ _**|
|32|10|15|18|17|**XTAR032C21_ _**|
## **Reversing Starters with Screw Terminals, Frame D—Maximum UL/CSA Ratings**
|**Single-Phase**<br>**115V**|**hp Ratings**<br>**230V**|**Three-Phase**<br>**200V**|**hp Ratings**<br>**230V**|**460V**|**575V**|**Catalog Number**12|
|---|---|---|---|---|---|---|
|3|7-1/2|10|15|30|40|**XTAR040D11_ _**|
|3|10|15|20|40|50|**XTAR050D11_ _**|
|5|15|20|25|50|60|**XTAR065D11_ _**|
## **Reversing Starters with Screw Terminals, Frame D—Maximum IEC Ratings**
|**AC-3**|**Three-Phase Motors 50–60 Hz**|**Three-Phase Motors 50–60 Hz**||||
|---|---|---|---|---|---|
|**Ie (A)**|**220/230V**|**380/400V**|**415V**|**660/690V**|**Catalog Number**12|
|40|12.5|18.5|24|23|**XTAR040D11_ _**|
|50<br>65|15.5<br>20|22<br>30|30<br>39|30<br>35|**XTAR050D11_ _**<br>**XTAR065D11_ _**|
## _**Notes**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-53** .
> 2 Underscore (_) indicates overload relay suffix required. See **Page V5-T1-54** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-52**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Starter Application Data**[1]
|**Starter Applica**|**tion Data**1||
|---|---|---|
|**Catalog Prefix**|**AC-3**|**Electrical Life (Operations)**|
|XTAE012B|12A|1 million|
|XTAE015B|15A|1.2 million|
|XTAE018C|18A|2 million|
## **Magnet Coil Suffix**
|**Coil Voltage**<br>**Suffix Code**<br>**Frames A–B**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24 Vdc<br>**TD**<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>120 Vdc<br>**AD**<br>220 Vdc<br>**BD**<br>12 Vdc<br>**RD**<br>48 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**|
|---|---|
||**Frames C–F**|
||110V 50 Hz, 120V 60 Hz<br>**A**|
||220V 50 Hz, 240V 60 Hz<br>**B**|
||230V 50 Hz<br>**F**|
||24V 50/60 Hz<br>**T**|
||24–27 Vdc<br>**TD**|
||415V 50 Hz, 480V 60 Hz<br>**C**|
||600V 60 Hz<br>**D**|
||208V 60 Hz<br>**E**|
||190V 50 Hz, 220V 60 Hz<br>**G**|
||240V 50 Hz, 277V 60 Hz<br>**H**|
||380V 50 Hz, 440V 60 Hz<br>**L**|
||400V 50 Hz<br>**N**|
||380V 60 Hz<br>**P**|
||12V 50/60 Hz<br>**R**|
||42V 50 Hz, 48V 60 Hz<br>**W**|
||48V 50 Hz<br>**Y**|
||110–130 Vdc<br>**AD**|
||200–240 Vdc<br>**BD**|
||48–60 Vdc<br>**WD**|
|||
|**Coil Voltage**<br>**Suffix Code**<br>**Frame G**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD**<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>42–48V 50/60 Hz<br>**W**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>48–60 Vdc<br>**WD**<br>**Frame H**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>24V 50/60Hz<br>**T**<br>42–48V 50/60Hz<br>**W**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>24–27 Vdc<br>**TD**<br>48–60 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**|
|---|---|
||**Frames L–N**|
||110–250 Vdc 40–60 Hz<br>**A**|
||250–500V 40–60 Hz<br>**C**|
||48–110 Vdc 40–60 Hz<br>**Y**|
||24–48 Vdc<br>**TD** 2|
||**Frames L–M, S-Series**|
||110–120V 50/60 Hz<br>**A**|
||220–240V 50/60 Hz<br>**B**|
||**Frames P–R**|
||230–250 Vdc 50–60 Hz<br>**B**|
|||
## _**Notes**_
> 1 See **Page V5-T1-111** for electrical life curves.
- 2 Frames L–M only.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-53**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Bimetallic Overload Relay Suffix**
|**Motor Full**<br>**Load Amperes**<br>**Suffix Code**<br>**For Use with**<br>**Contactor**<br>**Ampere Range**<br>**Overload Relay**<br>**Catalog Number**<br>**Frame B**<br>0.1–0.16<br>**P16**<br>7–15A<br>XTOBP16BC1<br>0.16–0.24<br>**P24**<br>7–15A<br>XTOBP24BC1<br>0.24–0.4<br>**P40**<br>7–15A<br>XTOBP40BC1<br>0.4–0.6<br>**P60**<br>7–15A<br>XTOBP60BC1<br>0.6–1<br>**001**<br>7–15A<br>XTOB001BC1<br>1–1.6<br>**1P6**<br>7–15A<br>XTOB1P6BC1<br>1.6–2.4<br>**2P4**<br>7–15A<br>XTOB2P4BC1<br>2.4–4<br>**004**<br>7–15A<br>XTOB004BC1<br>4–6<br>**006**<br>7–15A<br>XTOB006BC1<br>6–10<br>**010**<br>7–15A<br>XTOB010BC1<br>9–12<br>**012**<br>9–15A<br>XTOB012BC1<br>12–16<br>**016**<br>12–15A<br>XTOB016BC1<br>**Frame C**<br>0.1–0.16<br>**P16**<br>18–32A<br>XTOBP16CC1<br>0.16–0.24<br>**P24**<br>18–32A<br>XTOBP24CC1<br>0.24–0.4<br>**P40**<br>18–32A<br>XTOBP40CC1<br>0.4–0.6<br>**P60**<br>18–32A<br>XTOBP60CC1<br>0.6–1<br>**001**<br>18–32A<br>XTOB001CC1<br>1–1.6<br>**1P6**<br>18–32A<br>XTOB1P6CC1<br>1.6–2.4<br>**2P4**<br>18–32A<br>XTOB2P4CC1<br>2.4–4<br>**004**<br>18–32A<br>XTOB004CC1<br>4–6<br>**006**<br>18–32A<br>XTOB006CC1<br>6–10<br>**010**<br>18–32A<br>XTOB010CC1<br>10–16<br>**016**<br>18–32A<br>XTOB016CC1<br>16–24<br>**024**<br>18–32A<br>XTOB024CC1<br>24–32<br>**032**<br>25–32A<br>XTOB032CC1|**Motor Full**<br>**Load Amperes**<br>**Suffix Code**<br>**For Use with**<br>**Contactor**<br>**Ampere Range**<br>**Overload Relay**<br>**Catalog Number**|
|---|---|
||**Frame D**|
||6–10<br>**010**<br>40–72A<br>XTOB010DC1|
||10–16<br>**016**<br>40–72A<br>XTOB016DC1|
||16–24<br>**024**<br>40–72A<br>XTOB024DC1|
||24–40<br>**04**<br>40–72A<br>XTOB040DC1|
||40–57<br>**057**<br>50–72A<br>XTOB057DC1|
||50–65<br>**065**<br>65–72A<br>XTOB065DC1|
||65–75<br>**075**<br>65–72A<br>XTOB075DC1|
||**Frame F**|
||25–35<br>**035**<br>80–95A<br>XTOB055GC11|
||35–50<br>**050**<br>80–95A<br>XTOB050GC11|
||50–70<br>**070**<br>80–95A<br>XTOB070GC11|
||70–100<br>**100**<br>80–95A<br>XTOB100GC11|
||**Frame G**|
||25–35<br>**035**<br>115–170A<br>XTOB055GC11|
||35–50<br>**050**<br>115–170A<br>XTOB050GC11|
||50–70<br>**070**<br>115–170A<br>XTOB070GC11|
||70–100<br>**100**<br>115–170A<br>XTOB100GC11|
||95–125<br>**125**<br>115–170A<br>XTOB125GC11|
||120–150<br>**150**<br>150–170A<br>XTOB150GC11|
||145–175<br>**175**<br>150–170A<br>XTOB175GC11|
|||
## **Electronic Overload Relay Suffix**
|**XTOE Maximum**|**Overload Rating**||
|---|---|---|
|**Frame B**|**Standard Type Suffix**|**Ground Fault Type Suffix**|
|0.33–1.65A<br>1–5A|**5E1P6**<br>**5E005**|**5G1P6**<br>**5G005**|
|4–20A<br>**Frame C**|**5E020**|**5G020**|
|0.33–1.65A|**5E1P6**|**5G1P6**|
|1–5A|**5E005**|**5G005**|
|4–20A|**5E020**|**5G020**|
|9–45A|**5E045**|**5G045**|
|**Frame D**|||
|9–45A|**5E045**|**5G045**|
|20–100A|**5E100**|**5G100**|
|**Frame F, G**<br>20–100A|**5E100**|**5G100**|
|**Frame G**<br>35–175A|**5E175**|**5G175**|
## _**Note**_
> 1 Catalog number refers to direct mount overload relay. Add an **S** to the end of the catalog number for separate mount.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-54**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## _**Star-Delta (Wye-Delta) Starters**_
|**_ta) Starters_**||
|---|---|
|**Frame B—Maximum UL/CSA Ratings**<br>**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|3<br>3<br>2-1/2<br>10<br><20|K1M main contactor<br>**XTCE007B10_**|
||K5M delta contactor<br>**XTCE007B01_**|
||K3M star contactor<br>**XTCE007B01_**|
||Mechanical interlock<br>**XTCEXMLB**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…BC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLB**|
|3<br>5<br>7-1/2<br>10<br><20|K1M main contactor<br>**XTCE009B10_**|
||K5M delta contactor<br>**XTCE009B01_**|
||K3M star contactor<br>**XTCE009B01_**|
||Mechanical interlock<br>**XTCEXMLB**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…BC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLB**|
|5<br>5<br>10<br>15<br><20|K1M main contactor<br>**XTCE012B10_**|
||K5M delta contactor<br>**XTCE012B01_**|
||K3M star contactor<br>**XTCE012B01_**|
||Mechanical interlock<br>**XTCEXMLB**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…BC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLB**|
|**Frame B—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|12<br>3<br>5.5<br>7<br>5.5<br>5.5<br>—<br><20|K1M main contactor<br>**XTCE007B10_**|
||K5M delta contactor<br>**XTCE007B01_**|
||K3M star contactor<br>**XTCE007B01_**|
||Mechanical interlock<br>**XTCEXMLB**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…BC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLB**|
|16<br>4<br>7.5<br>8<br>7.5<br>7.5<br>—<br><20|K1M main contactor<br>**XTCE009B10_**|
||K5M delta contactor<br>**XTCE009B01_**|
||K3M star contactor<br>**XTCE009B01_**|
||Mechanical interlock<br>**XTCEXMLB**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…BC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLB**|
|22<br>5.5<br>11<br>14.5<br>11<br>11<br>—<br><20|K1M main contactor<br>**XTCE012B10_**|
||K5M delta contactor<br>**XTCE012B01_**|
||K3M star contactor<br>**XTCE012B01_**|
||Mechanical interlock<br>**XTCEXMLB**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…BC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLB**|
|**_Note_**<br>1Underscore (_) indicates magnet coil suffix required. See**Page V5-T1-62**.||
**1**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-55**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame C—Maximum UL/CSA Ratings**
|**Frame C—Maximum UL/CSA Ratings**||
|---|---|
|**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|7-1/2<br>7-1/2<br>15<br>20<br><20|K1M main contactor<br>**XTCE018C10_**|
||K5M delta contactor<br>**XTCE018C01_**|
||K3M star contactor<br>**XTCE018C01_**|
||Mechanical interlock<br>**XTCEXMLC**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…CC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLC**|
|10<br>15<br>30<br>40<br><20|K1M main contactor<br>**XTCE025C10_**|
||K5M delta contactor<br>**XTCE025C01_**|
||K3M star contactor<br>**XTCE025C01_**|
||Mechanical interlock<br>**XTCEXMLC**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…CC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLC**|
|15<br>20<br>40<br>50<br><20|K1M main contactor<br>**XTCE032C10_**|
||K5M delta contactor<br>**XTCE032C01_**|
||K3M star contactor<br>**XTCE032C01_**|
||Mechanical interlock<br>**XTCEXMLC**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…CC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLC**|
|**Frame C—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|30<br>7.5<br>15<br>19<br>18.5<br>18.5<br>—<br><20|K1M main contactor<br>**XTCE018C10_**|
||K5M delta contactor<br>**XTCE018C01_**|
||K3M star contactor<br>**XTCE018C01_**|
||Mechanical interlock<br>**XTCEXMLC**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…CC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLC**|
|45<br>11<br>22<br>30<br>30<br>22<br>—<br><20|K1M main contactor<br>**XTCE025C10_**|
||K5M delta contactor<br>**XTCE025C01_**|
||K3M star contactor<br>**XTCE025C01_**|
||Mechanical interlock<br>**XTCEXMLC**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…CC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLC**|
|55<br>15<br>30<br>39<br>37<br>30<br>—<br><20|K1M main contactor<br>**XTCE032C10_**|
||K5M delta contactor<br>**XTCE032C01_**|
||K3M star contactor<br>**XTCE032C01_**|
||Mechanical interlock<br>**XTCEXMLC**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…CC1**|
||(3) auxiliary contacts<br>**XTCEXFAC20**|
||Star-delta link kit<br>**XTCEXSDLC**|
_**Note**_ 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-62** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-56**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame D—Maximum UL/CSA Ratings**
|**Frame D—Maximum UL/CSA Ratings**||
|---|---|
|**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|20<br>25<br>50<br>60<br><20|K1M main contactor<br>**XTCE040D00_**|
||K5M delta contactor<br>**XTCE040D00_**|
||K3M star contactor<br>**XTCE040D00_**|
||Mechanical interlock<br>**XTCEXMLD**|
||K1T timingrelay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…DC1**|
||(2) auxiliarycontacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliarycontact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLD**|
|25<br>30<br>60<br>75<br><20|K1M main contactor<br>**XTCE050D00_**|
||K5M delta contactor<br>**XTCE050D00_**|
||K3M star contactor<br>**XTCE040D00_**|
||Mechanical interlock<br>**XTCEXMLD**|
||K1T timingrelay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…DC1**|
||(2) auxiliarycontacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliarycontact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLD**|
|40<br>50<br>100<br>125<br><20|K1M main contactor<br>**XTCE065D00_**|
||K5M delta contactor<br>**XTCE065D00_**|
||K3M star contactor<br>**XTCE040D00_**|
||Mechanical interlock<br>**XTCEXMLD**|
||K1T timingrelay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…DC1**|
||(2) auxiliarycontacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliarycontact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLD**|
|**Frame D—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|70<br>18.5<br>37<br>37<br>45<br>37<br>—<br><20|K1M main contactor<br>**XTCE040D00_**|
||K5M delta contactor<br>**XTCE040D00_**|
||K3M star contactor<br>**XTCE040D00_**|
||Mechanical interlock<br>**XTCEXMLD**|
||K1T timingrelay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…DC1**|
||(2) auxiliarycontacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliarycontact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLD**|
|90<br>22<br>45<br>45<br>55<br>45<br>—<br><20|K1M main contactor<br>**XTCE050D00_**|
||K5M delta contactor<br>**XTCE050D00_**|
||K3M star contactor<br>**XTCE040D00_**|
||Mechanical interlock<br>**XTCEXMLD**|
||K1T timingrelay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…DC1**|
||(2) auxiliarycontacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliarycontact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLD**|
|115<br>30<br>55<br>55<br>75<br>55<br>—<br><20|K1M main contactor<br>**XTCE065D00_**|
||K5M delta contactor<br>**XTCE065D00_**|
||K3M star contactor<br>**XTCE040D00_**|
||Mechanical interlock<br>**XTCEXMLD**|
||K1T timingrelay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…DC1**|
||(2) auxiliarycontacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliarycontact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLD**|
## _**Note**_
> 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-62** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-57**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame F—Maximum UL/CSA Ratings**
|**Frame F—Maximum UL/CSA Ratings**||
|---|---|
|**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|40<br>60<br>125<br>150<br><20|K1M main contactor<br>**XTCE080F00_**|
||K5M delta contactor<br>**XTCE080F00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock2<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…FC1**|
||(2) auxiliary contacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLF**|
|40<br>60<br>125<br>150<br><20|K1M main contactor<br>**XTCE095F00_**|
||K5M delta contactor<br>**XTCE095F00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock2<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…FC1**|
||(2) auxiliary contacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLF**|
|**Frame F—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|140<br>37<br>75<br>75<br>90<br>90<br>—<br><20|K1M main contactor<br>**XTCE080F00_**|
||K5M delta contactor<br>**XTCE080F00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock2<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…FC1**|
||(2) auxiliary contacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLF**|
|165<br>45<br>90<br>110<br>110<br>132<br>—<br><20|K1M main contactor<br>**XTCE095F00_**|
||K5M delta contactor<br>**XTCE095F00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock2<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…FC1**|
||(2) auxiliary contacts (K1M, K3M)<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLF**|
## _**Notes**_
- 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-62** .
- 2 If mechanical interlock of star contactor is required, it must be the same frame size of the delta contactor or use the same mechanical interlock, see **Page V5-T1-73** for mechanical interlocks. (Example: XTCE…L22_ and XTCE…M22_ both use mechanical interlock XTCEXMLM.)
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-58**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame G—Maximum UL/CSA Ratings**
|**Frame G—Maximum UL/CSA Ratings**||
|---|---|
|**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|50<br>60<br>125<br>150<br><20|K1M main contactor<br>**XTCE115G00_**|
||K5M delta contactor<br>**XTCE115G00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…GC1**|
||(2) auxiliary contacts<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLG**|
|75<br>100<br>200<br>250<br><20|K1M main contactor<br>**XTCE150G00_**|
||K5M delta contactor<br>**XTCE150G00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…GC1**|
||(2) auxiliary contacts<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLG**|
|**Frame G—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|200<br>55<br>110<br>132<br>132<br>160<br>—<br><20|K1M main contactor<br>**XTCE115G00_**|
||K5M delta contactor<br>**XTCE115G00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…GC1**|
||(2) auxiliary contacts<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLG**|
|260<br>75<br>132<br>148<br>160<br>160<br>—<br><20|K1M main contactor<br>**XTCE150G00_**|
||K5M delta contactor<br>**XTCE150G00_**|
||K3M star contactor<br>**XTCE080F00_**|
||Mechanical interlock<br>**XTCEXMLG**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…GC1**|
||(2) auxiliary contacts<br>**XTCEXFBG11**|
||(1) auxiliary contact (K5M)<br>**XTCEXFBG31**|
||Star-delta link kit<br>**XTCEXSDLG**|
**==> picture [191 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note<br>1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62 .<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-59**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame L—Maximum UL/CSA Ratings**
|**Frame L—Maximum UL/CSA Ratings**||
|---|---|
|**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|125<br>150<br>300<br>400<br><30|K1M main contactor<br>**XTCS250L22_**|
||K5M delta contactor<br>**XTCS250L22_**|
||K3M star contactor<br>**XTCS250L22_**|
||Mechanical interlock<br>**XTCEXMLM**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…LC1**|
|**Frame L—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|430<br>132<br>250<br>300<br>315<br>400<br>200<br><30|K1M main contactor<br>**XTCS250L22_**|
||K5M delta contactor<br>**XTCS250L22_**|
||K3M star contactor<br>**XTCS250L22_**|
||Mechanical interlock<br>**XTCEXMLM**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOB…LC1**|
|**Frame M—Maximum UL/CSA Ratings**<br>**Three-Phase hp Ratings**<br>**Max. Changeover**<br>**Time (sec)**<br>**200V**<br>**230V**<br>**460V**<br>**575V**|**Component**<br>**Description**<br>**Catalog Number**1|
|200<br>250<br>500<br>600<br><20|K1M main contactor<br>**XTCS400M22_**|
||K5M delta contactor<br>**XTCS400M22_**|
||K3M star contactor<br>**XTCS250L22_**|
||Mechanical interlock<br>**XTCEXMLM**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
|290<br>350<br>700<br>860<br><30|K1M main contactor<br>**XTCS500M22_**|
||K5M delta contactor<br>**XTCS500M22_**|
||K3M star contactor<br>**XTCS300M22_**|
||Mechanical interlock<br>**XTCEXMLM**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
|**Frame M—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|685<br>200<br>355<br>390<br>450<br>560<br>220<br><20|K1M main contactor<br>**XTCS400M22_**|
||K5M delta contactor<br>**XTCS400M22_**|
||K3M star contactor<br>**XTCS250L22_**|
||Mechanical interlock<br>**XTCSXMLM**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
|860<br>250<br>450<br>500<br>560<br>600<br>220<br><30|K1M main contactor<br>**XTCS500M22_**|
||K5M delta contactor<br>**XTCS500M22_**|
||K3M star contactor<br>**XTCS300M22_**|
||Mechanical interlock<br>**XTCEXMLM**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
## _**Notes**_
- 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-62** .
- 2 If mechanical interlock of star contactor is required, it must be the same frame size of the delta contactor or use the same mechanical interlock, see **Page V5-T1-73** for mechanical interlocks. (Example: XTCE…L22_ and XTCE…M22_ both use mechanical interlock XTCEXMLM.)
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-60**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Frame N—Maximum UL/CSA Ratings are not applicable.
|**Frame N—Maximum IEC Ratings**<br>**AC-3**<br>**Ie (A)**<br>**Three-Phase Motors 50–60 Hz**<br>**Max. Changeover**<br>**Time (sec)**<br>**220/230V**<br>**380/400V**<br>**415V**<br>**500V**<br>**660/690V**<br>**1000V**|**Component**<br>**Description**<br>**Catalog Number**1|
|---|---|
|1000<br>300<br>560<br>610<br>710<br>900<br>355<br><30|K1M main contactor<br>**XTCE580N22_**|
||K5M delta contactor<br>**XTCE580N22_**|
||K3M star contactor<br>**XTCE580N22_**|
||Mechanical interlock2<br>**XTCEXMLN**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
|1120<br>350<br>630<br>680<br>750<br>950<br>355<br><30|K1M main contactor<br>**XTCE650N22_**|
||K5M delta contactor<br>**XTCE650N22_**|
||K3M star contactor<br>**XTCE580N22_**|
||Mechanical interlock2<br>**XTCEXMLN**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
|1290<br>400<br>710<br>760<br>900<br>1200<br>1400<br><30|K1M main contactor<br>**XTCE750N22_**|
||K5M delta contactor<br>**XTCE750N22_**|
||K3M star contactor<br>**XTCE580N22_**|
||Mechanical interlock<br>**XTCEXMLN**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
|1400<br>450<br>800<br>850<br>950<br>1300<br>1400<br><30|K1M main contactor<br>**XTCE820N22_**|
||K5M delta contactor<br>**XTCE820N22_**|
||K3M star contactor<br>**XTCE580N22_**|
||Mechanical interlock<br>**XTCEXMLN**|
||K1T timing relay<br>**XTTR6A60S51**|
||Overload relay<br>**XTOT…C3S**|
|1700<br>560<br>1000<br>1050<br>1200<br>1700<br>1700<br><20|K1M main contactor<br>**XTCEC10N22_**|
||K5M delta contactor<br>**XTCEC10N22_**|
||K3M star contactor<br>**XTCE650N22_**|
||Mechanical interlock<br>**XTCEXMLN**|
||K1T timing relay<br>**XTTR6A60S51B**|
||Overload relay<br>**XTOT…C3S**|
## _**Notes**_
Main circuit: Depending on the coordination type required (that is, Type 1 or Type 2) it must be established whether the fuse protection and the input wiring for the main and delta contactors are to be common or separate.
Control circuit: If the combinations are used in the scope of the IEC/EN 60 204-1, VDE 0113 part 1, point 9.1.1 regarding the supply of control circuits is to be observed.
- 1 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-62** .
- 2 If mechanical interlock of star contactor is required, it must be the same frame size of the delta contactor or use the same mechanical interlock, see **Page V5-T1-73** for mechanical interlocks. (Example: XTCE…L22_ and XTCE…M22_ both use mechanical interlock XTCEXMLM.)
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-61**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Spare Auxiliary Contacts**
|**AC-3**|**K1M**|**K3M**|**K3M**|**K3M**|**K5M**|**K5M**|**K5M**|
|---|---|---|---|---|---|---|---|
|12–55|63|||63|||63|
|90–260|64<br>21<br>33|—||64|—||64|
||22<br>34|||||||
|||||||||
|315–1700|21<br>31||31<br>43|||31<br>43||
|||||||||
||22<br>32||32<br>44|||32<br>44||
## **Magnet Coil Suffix**
|**Coil Voltage**<br>**Suffix Code**<br>**Frames A–B**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24 Vdc<br>**TD**<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>120 Vdc<br>**AD**<br>220 Vdc<br>**BD**<br>12 Vdc<br>**RD**<br>48 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**<br>**Frames C–F**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD**<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>48–60 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**<br>**Frame G**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD**<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>42–48V 50/60 Hz<br>**W**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>48–60 Vdc<br>**WD**<br>**Frame H**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>24V 50/60Hz<br>**T**<br>42–48V 50/60Hz<br>**W**<br>110–130 Vdc<br>**AD**<br>200–240 Vdc<br>**BD**<br>24–27 Vdc<br>**TD**<br>48–60 Vdc<br>**WD**|**Coil Voltage**<br>**Suffix Code**|
|---|---|---|---|
||||**Frames L–N**|
||||110–250 Vdc 40–60 Hz<br>**A**|
||||250–500V 40–60 Hz<br>**C**|
||||48–110 Vdc 40–60 Hz<br>**Y**|
||||24–48 Vdc<br>**TD** 1|
||||**Frames L–M, S-Series**|
||||110–120V 50/60 Hz<br>**A**|
||||220–240V 50/60 Hz<br>**B**|
||||**Frames P–R**|
||||230–250 Vdc 50–60 Hz<br>**B**|
|||||
## **Overload Relay Settings (A)**
|**Setting**|**Starting**|
|---|---|
|**A**: INx 0.58|<<br>~~1~~5 sec|
|Motor protection in the star (wye) and delta configurations||
|**B**: INx 1|15–40 sec|
|Only partial motor protection in star position||
|**C**: INx 0.58<br>Motor not protected in star (wye) position|>40 sec|
|Timing relay set to approximately 10 sec||
## _**Note**_
> 1 Frames L–M only.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-62**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|||||||||
|---|---|---|---|---|---|---|---|
|**XTCC0_**|**XTCC Contactors for Three-Phase Capacitors**<br>**Three-Phase Capacitors, 50–60 Hz**<br>**Open kVAR Ratings**1<br>**Contact Sequence**<br>**230V**<br>**400V**<br>**525V**<br>**690V**||||||**Catalog Number**2|
|||||||||
||11<br>20<br>25<br>33.3||1<br>2<br>3<br>4<br>5<br>6<br>21<br>22<br>13<br>14||||**XTCC020C11_**|
||15<br>25<br>33.3<br>40<br>A1<br>A2||||1|3|**XTCC025C11_**|
||||||2|4||
|||||||||
||20<br>33.3<br>40<br>55||1<br>2<br>3<br>4<br>5<br>6<br>13<br>14||||**XTCC033D10_**|
||25<br>50<br>65<br>85<br>A1<br>A2||||1|3|**XTCC050D10_**|
||||||2|4||
## **Magnet Coil Suffix**
|**Magnet Coil Suffix**||
|---|---|
|**Coil Voltage**|**Suffix Code**|
|110V 50 Hz, 120V 60 Hz|**A**|
|220V 50 Hz, 240V 60 Hz|**B**|
|230V 50 Hz, 240V 60 Hz|**F**|
|400V 50 Hz, 440V 60 Hz|**N**|
|24V 50/60 Hz|**T**|
## _**Notes**_
Weld-resistant for capacitors with inrush current peaks up to 180 x IN.
1 With series resistors, without quick-discharge resistor.
2 Underscore (_) indicates magnet coil suffix required.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-63**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Engineering Notes for XTCC and XTCE Contactors for Power Factor Correction**_
## **Individual Compensation, Open Version**
|**Catalog**|**Switching**|**Duty in kVAR**|||
|---|---|---|---|---|
|**Number**|**230V**|**400V, 420V, 440V**|**525V**|**690V**|
|**XTCE007B**|1.5|3|3.5|5|
|**XTCE009B**|2|4|4.5|6|
|**XTCE012B**|2.5|4.5|5.5|7|
|**XTCE015B**|2.5|4.5|5.5|7|
|**XTCE018C**<br>**XTCE025C**|6.5<br>7|12<br>13.5|14.5<br>16|19<br>21|
|**XTCE032C**|7.5|14.5|17|22.5|
|**XTCE040D**|11|20.5|24.5|32|
|**XTCE050D**|11.5|22|26|34.5|
|**XTCE065D**|12.5|23.5|28|37|
|**XTCE080F**|16|30.5|36.5|48|
|**XTCE095F**<br>**XTCE115G**|18<br>24|34<br>46|41<br>54.5|54<br>72|
|**XTCE150G**|28|53|63.5|83.5|
|**XTCE580N**|175|300|400|300|
## **Group Compensation, with Reactor, Open Version**
|**Catalog**|**Switching**|**Duty in kVAR**|||
|---|---|---|---|---|
|**Number**|**230V**|**400V, 420V, 440V**|**525V**|**690V**|
|**XTCE007B**|4|7|7.5|12|
|**XTCE009B**|5|8|10|14|
|**XTCE012B**|5.5|1|12|16|
|**XTCE015B**|5.5|10|12|16|
|**XTCE018C**<br>**XTCE025C**|7.5<br>9|16<br>18|20<br>23|28<br>30|
|**XTCE032C**|10|20|24|32|
|**XTCE040D**|13|25|30|40|
|**XTCE050D**|16|30|36|48|
|**XTCE065D**|19|36|43|57|
|**XTCE080F**|30|58|68|90|
|**XTCE095**<br>**XTCE115G**|34<br>44|6<br>8|7<br>100|10<br>125|
|**XTCE150**|5|97|115|152|
|**XTCE250L**|110|190|260|340|
|**XTCE400M**|160|280|370|480|
|**XTCE500M**|220|390|500|680|
## **Group Compensation, without Reactor, Open Version**
|**Catalog**<br>**Number**|**Switching**<br>**230V**|**Duty in kVAR**<br>**400V, 420V, 440V**|**525V**|**690V**|
|---|---|---|---|---|
|**XTCC020C**|11|20|25|33.3|
|**XTCC025C**|15|25|33.3|40|
|**XTCC033D**|20|33.3|40|55|
|**XTCC050D**|25|50|65|85|
|**XTCE580N**|145|250|333|250|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-64**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Accessories**
## _**Auxiliary Contacts**_
Front-mounted snap-on auxiliary contacts for _**XT**_ contactors are available with screw or spring cage terminals in a variety of contact configurations.
## **Auxiliary Contacts Possible Combinations**
|**Auxiliary Contacts Possible Combinations**||
|---|---|
|**Frame**<br>**Size**<br>**Catalog**<br>**Number**<br>**Contactor**<br>**Built-In**<br>**Auxiliary**<br>**Fro**<br>**Tw**|**nt (Top) Mount**<br>**Side-Mount**<br>**Total Auxiliary**<br>**Contacts Available**<br>**o-Pole**<br>**Four-Pole**<br>**Single-Pole**<br>**Two-Pole**|
|A<br>**XTMC6A_ –**<br>**XTMC9A_**<br>1NO or 1NC<br>1<br>—|—<br>—<br>—<br>3|
||1<br>—<br>—<br>5|
||—<br>—<br>—|
|||
|B<br>**XTCE007B_ –**<br>**XTCE015B_**<br>1NO or 1NC<br>1<br>—<br>—|—<br>—<br>—<br>3|
||1<br>—<br>—<br>5|
||—<br>1<br>—<br>2|
||—<br>—|
|C<br>**XTCE018C_ –**<br>**XTCE032C_**<br>1NO or 1NC<br>1<br>—<br>—|—<br>—<br>—<br>3|
||1<br>—<br>—<br>5|
||—<br>—<br>1<br>3|
|||
|D<br>**XTCE040D00_ –**<br>**XTCE065D00_**<br>—<br>1<br>—|—<br>—<br>2<br>6|
||1<br>—<br>1<br>6|
||—<br>—|
|F–G<br>**XTCE080F00_ –**<br>**XTCE150G00_**<br>—<br>1<br>—<br>—|—<br>—<br>2<br>6|
||1<br>—<br>2<br>8|
||—<br>—<br>4<br>8|
||—<br>—|
|L–R<br>**XTCE185H22_ –**<br>**XTCEC20R22_**<br>2NO–2NC<br>—<br>—|—<br>2<br>8|
||—<br>—|
## _**Notes**_
Forced operation contact to IEC/EN 60947-5-1 Appendix L (positively driven), inside the auxiliary contact unit (not early close and late opening).
Auxiliary normally closed contact can be used as mirror contact to IEC/EN 60947-4-1 Appendix F (not late opening). No auxiliary contacts can be fitted between two contactors.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-65**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Auxiliary Contact Combinations**
**==> picture [487 x 610] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTMC6A_–XTMC9A_<br>XTMCXF...A_<br>Two-Pole or Four-Pole<br>Frame A<br>XTCE007B_–XTCE015B_<br>XTCEXF...C_<br>+ XTCE007B_–XTCE015B_ or Two-Pole or Four-Pole<br>Frame B<br>Not for use with mechanical interlock.<br>XTCE007B_– XTCE032C_<br>Two-Pole or Four-PoleXTCEXF...C_ or + XTCE018C_–XTCE032C_<br>Frame C<br>XTCE040D_– XTCE065D_ XTCE040D_– XTCE065D_<br>+ XTCEXF...G_ or + XTCEXF...G_<br>Two-Pole Four-Pole<br>Frame D<br>XTCE080F_–XTCE150G_<br>+ Two-Pole or Four-PoleXTCEXF...G_ or + + XTCE080F_–XTCE150G_<br>Frames F–G<br>+ + XTCE185H_–XTCEC20R_<br>Frames L–R<br>XTCEXSAB_<br>XTCEXSCC11<br>XTCEXSBN11 XTCEXSBN11 XTCEXSBN11 XTCEXSBN11<br>XTCEXSBN11 XTCEXSBN11 XTCEXSCN11 XTCEXSBN11 XTCEXSBN11 XTCEXSCN11<br>XTCEXSCR11 XTCEXSCR11<br>XTCEXSBR11 (Built-In) XTCEXSBR11 (Built-In)<br>+ +<br>+ + +<br>+ +<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-66**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Auxiliary Contacts**
## **XTCEXF_**
## **Frames B–C, Front (Top) Mount—Two-Pole**
|**Conventional Thermal Current,**||||||
|---|---|---|---|---|---|
|**Open at 60°C**|**Contact**|**Circuit**||**Pkg.**|**Screw Terminal**|
|**Ith = Ie, AC-1 in Amps**|**Configuration**|**Symbol**||**Qty.**1|**Catalog Number**|
|16|2NO||63<br>53|5|**XTCEXFAC20**|
||||54<br>64|||
|||||||
|16|1NO-1NC||5361|5|**XTCEXFAC11**4|
|||||||
||||54<br>62|||
|||||||
|16|2NC||51<br>61|5|**XTCEXFAC02**|
|||||||
||||52<br>62|||
|16|1NOE-1NCL||57 65|5|**XTCEXFALC11**2|
|||||||
||||58<br>66|||
|16|1NO-1NC|||5|**XTCEXFDC11**3|
|16|2NC||21<br>31|5|**XTCEXFCC02**3|
|||||||
||||22<br>32|||
## **XTCEXF_**
## **Frames B–C, Front (Top) Mount—Four-Pole**
|**Frames B–C, Front (Top) Mount—Four-Pole**||
|---|---|
|**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circ**<br>**Sym**|**uit**<br>**bol**<br>**Pkg.**<br>**Qty.**1<br>**Screw Terminal**<br>**Catalog Number**|
|16<br>4NO<br>54<br>53|5<br>**XTCEXFAC40**4<br><br>6373<br>6474<br><br>83<br>84|
|16<br>3NO-1NC<br>54<br>53|5<br>**XTCEXFAC31**4<br><br>61<br>62<br>73<br>74<br>83<br>84|
|16<br>2NO-2NC<br>54<br>53|5<br>**XTCEXFAC22**4<br><br>61<br>62<br>71<br>72<br>83<br>84|
|16<br>1NO-3NC<br>53<br>54|5<br>**XTCEXFAC13**<br>6171 81<br>82<br>72<br>62<br>|
|16<br>4NC<br>51<br>52|5<br>**XTCEXFAC04**<br><br><br>61<br>62<br>71<br>72 82<br>81|
|16<br>1NOE-1NCL<br>58<br>57|5<br>**XTCEXFCLC22**2<br><br>65<br>66<br>71<br>72<br>83<br>84|
|16<br>2NO-2NC<br>21<br>22<br>3<br>3|5<br>**XTCEXFCC22**3<br>1<br>2<br>43<br>44<br>53<br>54|
## _**Notes**_
- 1 Orders must be placed in multiples of package quantity listed.
- 2 1 early-make contact (1NOE), 1 late-break contact (1NCL).
- 3 To avoid duplicate terminal numbers in contact sequence, these auxiliary contacts should only be used with contactors having a built-in 1NO contact (XTCE…B10_, XTCE…C10_).
- 4 Catalog number is shown with screw type terminal. For spring cage, add a “ **C** ” before the last 2 digits. For example, to order a spring cage version of the XTCEXFAC22, change the catalog number to XTCEXFAC **C** 22.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-67**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1 XTCEXFATC_**
## **XTCEXFATC22**
## **XTCEXSAB_**
## **XTCEXSCC11**
**Frames B–C, Front (Top) Mount—Tall Version Two-Pole**[1]
|**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circuit**<br>**Symbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**|**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circuit**<br>**Symbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**|**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circuit**<br>**Symbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**|
|---|---|---|
|16<br>2NO<br>5<br>**XTCEXFATC20**<br>54<br>63<br>64<br>53|||
|16<br>1NO-1NC<br>5<br>**XTCEXFATC11**<br>54<br>5361<br>62|||
|16<br>2NC<br>5<br>**XTCEXFATC02**<br>51<br>52<br>61<br>62|||
|**Frames B–C, Front (Top) Mount—Tall Version Four-Pole**1<br>**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circuit**<br>**Symbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**|||
|16<br>2NO-2NC<br><br>|5<br>**XTCEXFATC22**<br>54<br>5361<br>62<br>71<br>72<br>83<br>84||
||||
||54<br>62|72|
|**Frames B–C, Front (Top) Mount—Electronic Contacts, Two- and Four-Pole**1<br>**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circuit**<br>**Symbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**|||
|1 mA–0.5A<br>2N0-2NC<br><br>|1<br>**XTCEXFARC22**3<br>54<br>5361<br>62<br>71<br>72<br>83<br>84||
|1 mA–5A<br>1NO-1NC|1<br>**XTCEXFARC11**3<br>54<br>5361<br>62||
||54<br><br>6||
|**Frame B, Side-Mount—Single-Pole**<br>**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Cir**<br>**Sy**|**cuit**<br>**mbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**||
|16<br>1NO|1<br>**XTCEXSAB10**4<br>53<br>54||
||||
|16<br>1NC<br>51<br>52|1<br>**XTCEXSAB01**4<br>||
|**Frame C, Side-Mount—Two-Pole**<br>**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Cir**<br>**Sy**|**cuit**<br>**mbol**<br>**Pkg.**<br>**Qty.**2<br>**Screw Terminal**<br>**Catalog Number**||
|10<br>1NO-1NC|1<br>**XTCEXSCC11**4<br>54<br>5361<br>62||
||54<br><br>6||
## _**Notes**_
Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NO [early make] and NC [late break] contacts) and for the built-in auxiliary contacts of the XTCE007B_–XTCE032C_. Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not NC [late break] contact). No auxiliary contacts can be fitted between two contactors.
- 1 Front (top) mount tall version is for use with Frame B electrical wire bridges and link kits (see **Page V5-T1-74** ) and toolless plug combination connection kits: XTCEXRLB, XTCEXSDLB, XTPAXTPCB, XTPAXTPCRB, XTPAX.
- 2 Orders must be placed in multiples of package quantity listed.
- 3 Low level inputs down to 1 mA (PLC communications). Ideal for functional safety applications.
- 4 Can be mounted to the left side of contactor only. Cannot be used in combination with front (top) mount auxiliary contacts or mechanical interlocks.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-68**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTCEXF_**
## **Frames D–G—Two-Pole**
|**Frames D–G—Two-Pole**||||||||
|---|---|---|---|---|---|---|---|
|**Conventional Thermal Current,**||||||||
|**Open at 60°C**|**Contact**|**Circuit**||||**Pkg.**|**Screw Terminal**|
|**Ith = Ie, AC-1 in Amps**|**Configuration**|**Symbol**||||**Qty.**1|**Catalog Number**|
|16|2NO||13||23|5|**XTCEXFBG20**|
||||14||24|||
|||||||||
|16|1NO-1NC|53||61||5|**XTCEXFAG11**|
|||||||||
|||54||62||||
|16|1NO-1NC|13||21||5|**XTCEXFBG11**|
|||||||||
|||14||22||||
|16|2NC|11||21||5|**XTCEXFBG02**|
|||||||||
|||12||22||||
## **XTCEXF_**
## **Frames D–G—Four-Pole**
|**Frames D–G—Four-Pole**||
|---|---|
|**Conventional Thermal Current,**<br>**Open at 60°C**<br>**Ith = Ie, AC-1 in Amps**<br>**Contact**<br>**Configuration**<br>**Circ**<br>**Sym**|**uit**<br>**bol**<br>**Pkg.**<br>**Qty.**1<br>**Screw Terminal**<br>**Catalog Number**|
|16<br>4NO-0NC<br>14<br>13|5<br>**XTCEXFBG40**<br><br>23<br>24<br>33<br>34<br>43<br>44|
|16<br>3NO-1NC<br>14<br>13|5<br>**XTCEXFBG31**<br><br>21<br>22<br>33<br>34<br>43<br>44|
|16<br>2NO-2NC<br>14<br>13|5<br>**XTCEXFBG22**<br><br>21<br>22<br>31<br>32<br>43<br>44|
|16<br>2NO-2NC<br>5<br>5|5<br>**XTCEXFAG_22**2<br>4<br>361<br>62<br>71<br>72<br>83<br>84|
|16<br>1NO-3NC<br>14<br>13|5<br>**XTCEXFBG13**<br><br>21<br>22<br>31<br>32<br>41<br>42|
|16<br>0NO-4NC<br>12<br>11|5<br>**XTCEXFBG04**<br><br>21<br>22<br>31<br>32<br>41<br>42|
|16<br>1NOE-1NCL<br>1<br>1|5<br>**XTCEXFBLG22**3<br>4<br>3 21<br>22<br>35<br>36<br>47<br>48|
||4<br>22<br>36|
## _**Notes**_
Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NO (early make) and NC (late break) contacts) and for the built-in auxiliary contacts of the XTCE007B_–XTCE032C_. Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not NC (late break) contact). No auxiliary contacts can be fitted between two contactors.
- 1 Orders must be placed in multiples of package quantity listed.
- 2 A “_” denotes catalog numbers are incomplete. To complete the catalog number for ordering a spring cage terminal, insert a **C** in the “_” position or remove “_” for screw type terminal.
- 3 One early-make contact (1NOE), one late-break contact (1NCL).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-69**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1 XTCEXS_**
## **XTCEXS_**
## **Frames D–H, Side Mount (Snap-On)—Two-Pole**
|**Conventional Free Air**||||||||
|---|---|---|---|---|---|---|---|
|**Thermal Current,**<br>**Ith = Ie, AC-1 in Amps**|**Contact**<br>**Configuration**|**Circuit**<br>**Symbol**||||**Pkg.**<br>**Qty.**1|**Screw Terminal**<br>**Catalog Number**|
|10|1NO–1NC||13|1<br>44<br>21<br>32|||**XTCEXSBN11**|
|10|1NOE–1NCL||14<br>17|43<br>31<br>22<br>48<br>25<br>36||1|**XTCEXSBLN11**2|
|||18<br>47<br>26<br>35||||||
|||||||||
|10|1NO–1NC||53|84<br>61|1<br>72||**XTCEXSCN11**3|
||||54|83<br>62|71|||
## **Frames L–R, Side Mount (Screw Mount)—Two-Pole**
|**Conventional Free Air**||||||||
|---|---|---|---|---|---|---|---|
|**Thermal Current,**|**Contact**|**Circuit**||||**Pkg.**|**Screw Terminal**|
|**Ith = Ie, AC-1 in Amps**|**Configuration**|**Symbol**||||**Qty.**1|**Catalog Number**|
|10|1NO–1NC||13|1<br>44<br>21<br>32|||**XTCEXSBR11**4|
||||14|43<br>22|31|||
|||||||||
|10|1NOE–1NCL||17|48<br>25<br>36||1|**XTCEXSBLR11**|
|||||||||
|||18<br>47<br>26<br>35||||||
|10|1NO–1NC||53|84<br>61|1<br>72||**XTCEXSCR11**|
||||54|83<br>62|71|||
## _**Notes**_
- 1 Orders must be placed in multiples of package quantity listed.
- 2 1 early-make contact (1NOE), 1 late-break contact (1NCL).
- 3 To avoid duplicate terminal numbers in contact sequence, the XTCEXSCN11 should be used with Frame D when a top mount auxiliary is also installed.
- 4 For replacement only. XTCEXSBR11 and XTCEXSBLR11 cannot be added onto side mount auxiliaries that come with the Frames L–R contactors as standard. To add auxiliaries onto the included side auxiliaries on Frames L–R contactors, use XTCEXSCR11.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-70**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Suppressors**_
The switching of contactor coils can generate voltage transients that may cause arching on switch contacts and/or damage electronics on the control line. Either an RC or varistor suppressor is recommended in these types of applications. All _**XT**_ DC contactor coils have built-in suppression.
Varistor suppressors clamp the voltage transient above the maximum coil voltage and are recommended when the level of the transient is known to not exceed the coil voltage. RC suppressors slow and reduce the level of the voltage transient but do not clamp them at a specific level. The slowing of the transient can reduce electrical interference. These are recommended in applications where operating rates are high.
|**XTCEXVS_**|**XTCEXVS_**|**XTCEXVS_**|**XTCEXVS_**|**XTCEXVS_**|**XTCEXVS_**|||**Varistor Suppressor**|**Varistor Suppressor**|**Varistor Suppressor**12||
|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||**For Use**|**Pkg.**||
|||||||||**Voltage**|**with…**|**Qty.**3|**Catalog Number**|
|||||||||24–48|XTCE007B–|10|**XTCEXVSBW**|
|||||||||48–130|XTCE015B,<br>XTCF020B|10|**XTCEXVSBA**|
|||||||||130–240||10|**XTCEXVSBB**|
|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**||||||240–500||10|**XTCEXVSBC**|
|||||||||24–48|XTCE018C–|10|**XTCEXVSCW**|
|A1||||||||48–130|XTCE032C|10|**XTCEXVSCA**|
|||||||||130–240||10|**XTCEXVSCB**|
|A2||||||||||||
|||||||||240–500||10|**XTCEXVSCC**|
|||||||||24–48|XTCE040D–|10|**XTCEXVSFW**|
|||||||||48–130|XTCE095F|10|**XTCEXVSFA**|
|||||||||130–240||10|**XTCEXVSFB**|
|||||||||240–500||10|**XTCEXVSFC**|
## **XTCEXVS_**
## **Contact Sequence**
## **RC Suppressor**[12]
## **XTCEXRS_**
|||||||||**Voltage**|**For Use**<br>**with…**|**Pkg.**<br>**Qty.**3|**Catalog Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||24–48<br>48–130|XTCE007B–<br>XTCE015B,<br>XTCF020B|10<br>10|**XTCEXRSBW**<br>**XTCEXRSBA**|
|||||||||110–240||10|**XTCEXRSBB**|
|**Contact Sequence**<br>A1<br>A2||**Contact Sequence**|**Contact Sequence**<br>~~rt~~<br>‘~~T~~t<br>~~He~~|||||240–500<br>24–48<br>XTCE018C–<br>XTCE032C<br>110–130<br>130–240<br>~~—~~<br>~~a~~||10<br>**XTCEXRSBC**<br>10<br>**XTCEXRSCW**<br>10<br>**XTCEXRSCA**<br>10<br>**XTCEXRSCB**<br>~~OO~~<br>~~ee~~||
|||||||||240–500||10|**XTCEXRSCC**|
|||||||||24–48|XTCE040D–|10|**XTCEXRSFW**|
|||||||||110–130|~~X~~TCE095F|10|**XTCEXRSFA**|
|||||||||130–240||10|**XTCEXRSFB**|
|||||||||240–500||10|**XTCEXRSFC**|
## **Contact Sequence**
**Varistor Suppressor with Integrated LED**[12]
## **XTCEXVSL_**
|||||||||||**Voltage**<br>**AC**|**For Use**<br>**with…**|**Pkg.**<br>**Qty.**3|**Catalog Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||24–48<br>130–240|XTCE007B–<br>XTCE015B|10<br>10|**XTCEXVSLBW**<br>**XTCEXVSLBB**|
|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|**Contact Sequence**|||||||24–48<br>130–240|XTCE018C–<br>XTCE032C|10<br>10|**XTCEXVSLCW**<br>**XTCEXVSLCB**|
|A1<br>A2||||||||||24–48<br>130–240|XTCE040D–<br>XTCE095F|10<br>10|**XTCEXVSLFW**<br>**XTCEXVSLFB**|
## **Contact Sequence**
## _**Notes**_
- 1 Note dropout delay.
- 2 For AC operated contactors, 50–60 Hz. DC operated contactors and XTCE115G_ to XTCE170G_ have a built-in suppressor circuit.
- 3 Orders must be placed in multiples of package quantity listed.
## **XTCEXDSB**
## **Free-Wheel Diode Suppressor**[4]
- 4 In addition to the built-in suppressor circuit for DC actuated contactors. Prevents negative breaking voltage when contactors are used in combination with a safety PLC.
|**Voltage**|**For Use**|**Pkg.**||
|---|---|---|---|
|**DC**|**with…**|**Qty.**3|**Catalog Number**|
|12–250|XTCE007B–|10|**XTCEXDSB**|
||XTCE015B,|||
||XTCF020B|||
## **Contact Sequence**
A1 [ A2
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-71**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**Electronic Timer Modules**_
## **Frames B–C Contactors (7–32A)**[1]
|||||**Contact**||**Timing**|**For Use**|**Pkg.**||
|---|---|---|---|---|---|---|---|---|---|
|**XTCEXTE_**|||**Voltage**<br>**On-Delay**|**Sequence**||**Range**|**with…**|**Qty.**2|**Catalog Number**|
|24 Vac/Vdc<br>0.05s–1s<br>0.5s–10s<br>5s–100s<br>XTCE…B_<br>XTCE…C_<br>1<br>**XTCEXTEEC11T**<br>100–130 Vac<br>1<br>**XTCEXTEEC11A**<br>200–240 Vac<br>1<br>**XTCEXTEEC11B**<br>**Off-Delay**<br>24 Vac/Vdc<br>0.05s–1s<br>XTCE…B_<br>XTCE…C_<br>1<br>**XTCEXTED1C11T**<br>100–130 Vac<br>1<br>**XTCEXTED1C11A**<br>200–230 Vac<br>1<br>**XTCEXTED1C11B**<br>57<br>58<br>65<br>66<br>A1<br>A2<br>57<br>58<br>65<br>66<br>A1<br>A2<br>~~UG~~<br>~~ToT~~||||||||||
||||24 Vac/Vdc<br>100–130 Vac<br>200–240 Vac|57<br>58<br>65<br>66<br>A1<br>A2<br>~~TT~~||0.5s–10s|XTCE…B_<br>XTCE…C_|1<br>1<br>1|**XTCEXTED10C11T**<br>**XTCEXTED10C11A**<br>**XTCEXTED10C11B**|
||||24 Vac/Vdc<br>100–130 Vac<br>200–240 Vac|57<br>58<br>65<br>66<br>A1<br>A2<br>~~ToT~~||5s–100s|XTCE…B_<br>XTCE…C_|1<br>1<br>1|**XTCEXTED100C11T**<br>**XTCEXTED100C11A**<br>**XTCEXTED100C11B**|
||||**Star-Delta**|||||||
||||24 Vac/Vdc<br>100–130 Vac<br>200–240 Vac<br>~~en ~~|57<br>58<br>67<br>68<br>A1<br>A2<br> ~~a.~~||1s–30s|XTCE…B_<br>XTCE…C_|1<br>**XTCEXTEYC20T**<br>1<br>**XTCEXTEYC20A**<br>1<br>**XTCEXTEYC20B**<br>~~OO~~||
|**XTCEXTESHRD**|||**Sealable Shroud**<br>—<br>Transparent sealable shroud used to||||XTCEXTEE,|1|**XTCEXTESHRD**|
|||||protect electronic timer modules from<br>unwanted access|protect electronic timer modules from||XTCEXTED,<br>XTCEXTEY|||
## _**Notes**_
- 1 Front (top) mounted timer modules for use with XTCE…B and XTCE…C contactors. Cannot be combined with top-mount auxiliary contacts, XTCEXF…C_.
- 2 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-72**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Additional Accessories**_
|**XMLB**<br>**XML_**<br>**XMLM**<br>**XMLN**<br>**XRLB**<br>**XRL_**|**Mechanical Interlock**1<br>**For Use**<br>**with…**<br>**Pkg.**<br>**Qty.**2<br>**Catalog Number**|
|---|---|
||XTCE007B–XTCE015B,<br>XTCF020B<br>5<br>**XTCEXMLB**|
||XTCE018C–XTCE032C,<br>XTCF032C–XTCF045C<br>1<br>**XTCEXMLC**|
||XTCE040D–XTCE072D,<br>XTCF063D–XTCF080D<br>1<br>**XTCEXMLD**|
||XTCE080F–XTCE170G,<br>XTCF125G–XTCF200G<br>1<br>**XTCEXMLG**3|
||XTCE185H–XTCE570M<br>1<br>**XTCEXMLM**|
||XTCE580N–XTCEC10N<br>1<br>**XTCEXMLN**3|
||**Reversing Link Kits**<br>**For Use**<br>**with…**<br>**Pkg.**<br>**Qty.**2<br>**Catalog Number**|
||XTCE007B–XTCE015B<br>1<br>**XTCEXRLB**4|
||XTCE018C–XTCE032C<br>1<br>**XTCEXRLC**|
||XTCE040D–XTCE065D<br>1<br>**XTCEXRLD**|
||XTCE080F–XTCE150G<br>1<br>**XTCEXRLG**|
Main current wiring for reversing combinations. Includes paralleling bridge and reversing bridge. Does not include mechanical interlock, see table on this page.
|**XSDLB**<br>**XSDL_**|**Star-Delta (Wye-Delta) Link Kits**<br>**For Use**<br>**with…**<br>**Pkg.**<br>**Qty.**2<br>**Catalog Number**|
|---|---|
||XTCE007B–XTCE015B<br>1<br>**XTCEXSDLB**3|
||XTCE018C–XTCE032C<br>1<br>**XTCEXSDLC**|
||XTCE040D–XTCE072D<br>1<br>**XTCEXSDLD**|
||XTCE080F–XTCE095F<br>1<br>**XTCEXSDLF**|
||XTCE115G–XTCE150G<br>1<br>**XTCEXSDLG**|
Main current wiring for star-delta (wye-delta) combinations. includes paralleling bridge, reversing bridge and star-delta bridge. Does not include mechanical interlock, see table on this page.
## **Paralleling Bridge**
||**Paralleling Bridge**|
|---|---|
|**XPBB**<br>**XPBC**|**For Use**<br>**with…**<br>**Pkg.**<br>**Qty.**2<br>**Catalog Number**|
||XTCE007B–XTCE015B<br>20<br>**XTCEXPBB**|
||XTCE018C–XTCE032C<br>20<br>**XTCEXPBC**|
Component part of reversing link kit (XTCEXRL_). Parallels the phases on the line-side of two contactors.
## **Reversing Bridge**
||**Reversing Bridge**|
|---|---|
|**XRBB**<br>**XRB_**|**For Use**<br>**with…**<br>**Pkg.**<br>**Qty.**2<br>**Catalog Number**|
||XTCE007B–XTCE015B<br>20<br>**XTCEXRBB**|
||XTCE018C–XTCE032C<br>20<br>**XTCEXRBC**|
||XTCE040D–XTCE065D<br>10<br>**XTCEXRBD**|
Component part of reversing link kit (XTCEXRL_). Reverses the phases on the load-side of two contactors.
## _**Notes**_
> 1 For two contactors with AC or DC operated magnet system which are horizontally or vertically mounted. For Frames B–G, mechanical lifespan is 2.5 x 106 operations and the distance between contactors is 0 mm. For Frames L–N, mechanical lifespan is 5 x 10[6] operations and no auxiliary contact can be mounted between the mechanical interlock and the contactor—the distance between contactors is 15 mm.
> 2 Orders must be placed in multiples of package quantity listed.
> 3 XTCEXMLG and XTCEXMLN consist of an interlock element and mounting plate.
> 4 Also includes interlocking bridge (XTCEXLBB). The following control cables are integrated for electrical interlock: K1M: A1–K2M: 21; K1M: 21–K2M: A1; K1M: A2–K2M: A2.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-73**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Electrical Interlocking Bridge**
**For Use Pkg. with… Qty.**[1] **Catalog Number** XTCE007B–XTCE015B 20 **XTCEXLBB**
## **Parallel Link**[456]
**For Use Pkg. with… Qty.**[1] **Catalog Number** XTCE007B –XTCE015B 5 **XTCEXPLKB**
**XTCEXPLKB** XTCE007B –XTCE015B
## **Star-Delta (Wye-Delta) Bridge**
**For Use Pkg. with… Qty.**[1] **Catalog Number XTCEXPLK_** ~~a~~ **XTCEXSDB** XTCE007B–XTCE015B 20 **XTCEXSDBB**[2]
|XTCE018C –XTCE032C<br>5<br>**XTCEXPLKC**<br>~~ee~~|
|---|
|XTCE040D –XTCE072D<br>1<br>**XTCEXPLKD**<br>XTCE080F–XTCE170G<br>1<br>**XTCEXPLKG**<br>~~oe~~|
**XTCEXSDB_** XTCE080F–XTCE170G 1 **XTCEXSDBG XTCEXPLKL185** XTCE185L 1 **XTCEXPLKL185** XTCE185L–XTCE400M 1 **XTCEXSDB400** XTCE500M 1 **XTCEXSDB500** ~~aa~~ Component part of star-delta link kit (XTCEXSDL_). Commons the three phases on the line side of shorting contactor. For using one contactor per phase. Each package comes with
For using one contactor per phase. Each package comes with two links for line: load.
## **Connector**
**==> picture [230 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
For Use Pkg.<br>with… Qty. [1] Catalog Number<br>XTCEXCNC XTCE007B–XTCE032C 50 XTCEXCNC<br>XTCEXCNG XTCE040D–XTCE170G 10 XTCEXCNG<br>**----- End of picture text -----**<br>
|**XGKE-GE**|**Contactor Labels**|||
|---|---|---|---|
||**For Use**|**Pkg.**||
||**with…**|**Qty.**|**Catalog Number**|
||XTC…|25|**XGKE-GE**7|
## _**Notes**_
- 1 Orders must be placed in multiples of package quantity listed.
- 2 Frame B is toolless connection type.
- 3 For mechanically arranging contactors in combinations. Distance between contactors is 0 mm.
- 4 Fourth pole can be broken off: four-pole: Ith = 60A; three-pole: Ith = 50A.
- 5 AC-1 current carrying capacity of the contactor increases by a factor of 2.5. For XTCEXPLKL185, one shroud is included for protection against accidental contact.
- 6 Protected against accidental contact in accordance with IEC 536.
- 7 Quantity 1 equals one sheet. One sheet contains 240 labels.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-74**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|**CI-K Basic Enclosures**|**CI-K Basic Enclosures**<br>**Dimensions in Inches (mm)**|**CI-K Basic Enclosures**<br>**Dimensions in Inches (mm)**|**CI-K Basic Enclosures**12|||||
|---|---|---|---|---|---|---|---|
||**Width**|**Height**|**External**<br>**Depth**|**Internal**<br>**Depth**|**Internal Mounting Type**|**Pkg.**<br>**Qty.**|**Catalog Number**|
||3.94 (100.0)|6.30 (160.0)|3.94 (100.0)|2.87 (73.0)<br>3.11 (79.0)|With mounting rail<br>With mounting plate|1|**CI-K2X-100-TS-NA**3<br>**CI-K2X-100-M-NA**3|
||||5.71 (145.0)|4.65 (118.0)|With mounting rail||**CI-K2X-145-TS-NA**3|
|||||4.88 (124.0)|With mounting plate||**CI-K2X-145-M-NA**3|
||4.72 (120.0)|7.87 (200.0)|4.92 (125.0)|3.66 (93.0)|With mounting rail|1|**CI-K3X-125-TS-NA**4|
||||6.30 (160.0)|3.86 (98.0)<br>5.04 (128.0)|With mounting plate<br>With mounting rail||**CI-K3X-125-M-NA**4<br>**CI-K3X-160-TS-NA**4|
|||||5.24 (133.0)|With mounting plate||**CI-K3X-160-M-NA**4|
||6.30 (160.0)|9.45 (240.0)|6.30 (160.0)|5.04 (128.0)|With mounting rail|1|**CI-K4X-160-TS-NA**4|
|||||5.24 (133.0)|With mounting plate||**CI-K4X-160-M-NA**4|
||7.87 (200.0)|11.02 (280.0)|6.30 (160.0)|5.04 (128.0)|With mounting rail|1|**CI-K5X-160-TS-NA**4|
|||||5.24 (133.0)|With mounting plate||**CI-K5X-160-M-NA**4|
## **XTCEXCN_**
## **Terminal Lug Kit—Set of Three Lugs**
|**For Use**||**Pkg.**||
|---|---|---|---|
|**with…**<br>XTCE500M, XTCE570M|**Description**<br>#4-500 kcmil two-phase Cu/Al 500A|**Qty.**5<br>1|**Catalog Number**<br>**XTCEXTL500**|
||Also for use with XTCS series|||
## **Terminal Flat Bar**[6]
## **XTCEXTFB6_**
|**Terminal Flat Bar**[6]<br>**XTCEXTFB6_**||
|---|---|
|**For Use**<br>**Pkg.**||
|**with…**<br>**Qty.**5<br>XTCE500M–XTCE570M<br>1<br>XTCE750N–XTCE820N<br>1<br>“ree ~~—_—_—<$<$_$_$_$_$_$_$_$__~~|**Catalog Number**<br>**XTCEXTFB650**<br>**XTCEXTFB820**|
|For connection of a flat strip conductor. Comes with control|For connection of a flat strip conductor. Comes with control|
|circuit terminal (consisting of three flat strip conductor<br>terminals). Also for use with XTCS series.||
## **Terminal Shroud**
## **XTCEXTS_**
|**Terminal Shroud**|||
|---|---|---|
|**For Use**|**Pkg.**||
|**with…**<br>XTCE185H–XTCE225H<br>XTCE250L–XTCE400M|**Qty.**5<br>1<br>1|**Catalog Number**<br>**XTCEXTS225**<br>**XTCEXTS400**|
|XTCE500M–XTCE570M<br>XTCE580N–XTCE650N|1<br>1|**XTCEXTS500**<br>**XTCEXTS650**|
|XTCE750N–XTCEC10N|1|**XTCEXTS820**|
## **Terminal Lug Assembly**
**XTCEXTLA400**
**For Use Pkg. with… Qty.**[5] **Catalog Number** XTCE185–XTCE225H 1 **XTCEXTLA225A** SS ~~a~~ XTCS250L–XTCS400M, 1 **XTCEXTLA400** XTCE250L_–XTCE400M_
For connection of: round conductor, flexible and stranded, flat strip conductor, with control circuit terminal. See **Page V5-T1-97** for terminal capacities. Consists of 3 integrated lugs for line or load side. Also for use with XTCS series.
## _**Notes**_
> 1 Enclosure base RAL 9005, black/enclosure top only RAL 7035. light gray.
- 2 Degree of protection—IEC: IP65; UL/CSA: Type 1, 3R, 4X, 12, 13—indoor and outdoor use.
- 3 CI-K2X_: 4 x 1/2 inch knockouts.
- 4 CI-K3X_, CI-K4X_, CI-K5X_: Smooth overall with sharp corners.
- 5 Orders must be placed in multiples of package quantity listed.
> 6 Not UL listed.
Protection against direct contact with connection lugs when touched vertically from the front. Also for use with XTCS series.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-75**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## **Renewal Parts**
## **Replacement Coil—Frame C**
## **Replacement Coil—Frame F**[1]
**XTCERENC_**
|**Voltage**<br>110/50 120/60<br>110–130 Vdc<br>220/50 240/60<br>200–240 Vdc<br>415/50 480/60<br>600/60<br>208/60<br>230/50<br>190/50 220/60<br>~~<_<~~|**Coil**<br>**Suffix**<br>**A**<br>**AD**<br>**B**<br>**BD**<br>**C**<br>**D**<br>**E**<br>**F**<br>**G**<br>~~<_<~~|**Catalog Number**<br>**XTCERENCOILCA**<br>**XTCERENCOILCAD**<br>**XTCERENCOILCB**<br>**XTCERENCOILCBD**<br>**XTCERENCOILCC**<br>**XTCERENCOILCD**<br>**XTCERENCOILCE**<br>**XTCERENCOILCF**<br>**XTCERENCOILCG**<br>~~<_<~~|**Voltage**<br>110/50 120/60<br>110–130 Vdc<br>220/50 240/60<br>200–240 Vdc<br>415/50 480/60<br>600/60<br>208/60<br>230/50<br>190/50 220/60|**Coil**<br>**Suffix**<br>**A**<br>**AD**<br>**B**<br>**BD**<br>**C**<br>**D**<br>**E**<br>**F**<br>**G**|**Catalog Number**<br>**XTCERENCOILFA**<br>**XTCERENCOILFAD**<br>**XTCERENCOILFB**<br>**XTCERENCOILFBD**<br>**XTCERENCOILFC**<br>**XTCERENCOILFD**<br>**XTCERENCOILFE**<br>**XTCERENCOILFF**<br>**XTCERENCOILFG**|
|---|---|---|---|---|---|
|240/50 277/60|**H**|**XTCERENCOILCH**|240/50 277/60|**H**|**XTCERENCOILFH**|
|380/50 440/60|**L**|**XTCERENCOILCL**|380/50 440/60|**L**|**XTCERENCOILFL**|
|400/50<br>380/60|**N**<br>**P**|**XTCERENCOILCN**<br>**XTCERENCOILCP**|400/50<br>380/60|**N**<br>**P**|**XTCERENCOILFN**<br>**XTCERENCOILFP**|
|12/50 12/60|**R**|**XTCERENCOILCR**|12/50 12/60|**R**|**XTCERENCOILFR**|
|12–14 Vdc|**RD**|**XTCERENCOILCRD**|24/50 24/60|**T**|**XTCERENCOILFT**|
|24/50 24/60|**T**|**XTCERENCOILCT**|24–27 Vdc|**TD**|**XTCERENCOILFTD**|
|24–27 Vdc|**TD**|**XTCERENCOILCTD**|42/50 48/60|**W**|**XTCERENCOILFW**|
|42/50 48/60|**W**|**XTCERENCOILCW**|48–60 Vdc|**WD**|**XTCERENCOILFWD**|
|48–60 Vdc|**WD**|**XTCERENCOILCWD**|48/50|**Y**|**XTCERENCOILFY**|
|48/50|**Y**|**XTCERENCOILCY**||||
|**Voltage**<br>**Coil**<br>**Suffix**<br>**Catalog Number**<br>110/50 120/60<br>**A**<br>**XTCERENCOILCA**<br>110–130 Vdc<br>**AD**<br>**XTCERENCOILCAD**<br>220/50 240/60<br>**B**<br>**XTCERENCOILCB**<br>~~<_<~~|
|---|
## **Replacement Coil—Frame G**[2]
## **Replacement Coil—Frame D**
||**Coil**||
|---|---|---|
|**Voltage**|**Suffix**|**Catalog Number**|
|100–120V 50/60|**A**|**XTCERENCOILGA**|
|110–130 Vdc|**AD**|**XTCERENCOILGAD**|
|190–240V 50/60|**B**|**XTCERENCOILGB**|
|200–240 Vdc|**BD**|**XTCERENCOILGBD**|
|480–500V 50/60<br>380–440V 50/60|**C**<br>**L**|**XTCERENCOILGC**<br>**XTCERENCOILGL**|
|4/50 24/60|**T**|**XTCERENCOILGT**|
|24–27 Vdc|**TD**|**XTCERENCOILGTD**|
|42–48V 50/60|**W**|**XTCERENCOILGW**|
|48–60 Vdc|**WD**|**XTCERENCOILGWD**|
||**Coil**||
|---|---|---|
|**Voltage**|**Suffix**|**Catalog Number**|
|110/50 120/60|**A**|**XTCERENCOILDA**|
|110–130 Vdc|**AD**|**XTCERENCOILDAD**|
|220/50 240/60|**B**|**XTCERENCOILDB**|
|200–240 Vdc|**BD**|**XTCERENCOILDBD**|
|415/50 480/60<br>600/60|**C**<br>**D**|**XTCERENCOILDC**<br>**XTCERENCOILDD**|
|208/60|**E**|**XTCERENCOILDE**|
|230/50|**F**|**XTCERENCOILDF**|
|190/50 220/60|**G**|**XTCERENCOILDG**|
|240/50 277/60<br>380/50 440/60|**H**<br>**L**|**XTCERENCOILDH**<br>**XTCERENCOILDL**|
|400/50<br>380/60<br>12/50 12/60|**N**<br>**P**<br>**R**|**XTCERENCOILDN**<br>**XTCERENCOILDP**<br>**XTCERENCOILDR**|
|12–14 Vdc|**RD**|**XTCERENCOILDRD**|
|24/50 24/60|**T**|**XTCERENCOILDT**|
|24–27 Vdc<br>42/50 48/60|**TD**<br>**W**|**XTCERENCOILDTD**<br>**XTCERENCOILDW**|
|48–60 Vdc|**WD**|**XTCERENCOILDWD**|
|48/50|**Y**|**XTCERENCOILDY**|
## _**Notes**_
- 1 Frame F replacement coils can only be used with contactors having the following date codes: DC coils, 2706 or later; AC coils, 4706 or later.
- 2 Frame G replacement coils can only be used with contactors having date codes of 2706 or later.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-76**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**Replacement Coil—Frame H**
||**Coil**||
|---|---|---|
|**Voltage**|**Suffix**|**Catalog Number**|
|100–120V 50/60 Hz|**A**|**XTCERENCOILHA**|
|190–240V 50/60 Hz|**B**|**XTCERENCOILHB**|
|480–500V 50/60 Hz|**C**|**XTCERENCOILHC**|
|380–440V 50/60 Hz|**L**|**XTCERENCOILHL**|
|24V 50/60Hz|**T**|**XTCERENCOILHT**|
|42–48V 50/60Hz|**W**|**XTCERENCOILHW**|
|110–130 Vdc|**AD**|**XTCERENCOILHAD**|
|200–240 Vdc|**BD**|**XTCERENCOILHBD**|
|24–27 Vdc|**TD**|**XTCERENCOILHTD**|
|48–60 Vdc|**WD**|**XTCERENCOILHWD**|
## **Replacement Coil—Frame L**[1]
||**Coil**||
|---|---|---|
|**Voltage**|**Suffix**|**Catalog Number**|
|110–250 Vac/Vdc|**A**|**XTCERENCOILLA**|
|250–500V 40–60|**C**|**XTCERENCOILLC**|
|24–48 Vdc|**TD**|**XTCERENCOILLTD**|
|48–110 Vac/Vdc|**Y**|**XTCERENCOILLY**|
**Replacement Coil—Frame L, S-Series**
||||**Coil**||
|---|---|---|---|---|
|**Voltage**|||**Suffix**|**Catalog Number**|
|110–120V|50/60|Hz|**A**|**XTCSRENCOILLA**|
|220–240V|50/60|Hz|**B**|**XTCSRENCOILLB**|
## **Replacement Contact Kit**
|**For Use with…**|**Catalog Number**|
|---|---|
|XTCE040D–XTCE065D|**XTCERENCONTACTD**|
|XTCE085F–XTCE095F|**XTCERENCONTACTF**|
|XTCE115G–XTCE150G|**XTCERENCONTACTG**|
|XTCE185H–XTCE225H<br>XTCE250L–XTCE300L|**XTCERENCONTACTH**<br>**XTCERENCONTACTL**|
|XTCE300M|**XTCERENCONTACTM300**|
|XTCE400M|**XTCERENCONTACTM400**|
|XTCE500M|**XTCERENCONTACTM500**|
## **Replacement Vacuum Tube Assembly**
|**Replacement Vacuum**|**Tube Assembly**|
|---|---|
|**For Use with…**<br>XTCE580N|**Catalog Number**<br>**XTCERENVACT580**|
|XTCE650N|**XTCERENVACT650**|
|XTCE750N|**XTCERENVACT750**|
|XTCE820N|**XTCERENVACT820**|
## **Replacement Arc Chamber**
|**For Use with…**|**Catalog Number**|
|---|---|
|XTCE250L|**XTCERENARC250**|
|XTCE300M|**XTCERENARC300**|
|XTCE400M|**XTCERENARC400**|
|XTCE500M–XTCE570M|**XTCERENARC500**|
## _**Note**_
> 1 Electronic modules including coils.
## **Replacement Coil—Frame M**[1]
||**Coil**||
|---|---|---|
|**Voltage**|**Suffix**|**Catalog Number**|
|110–250 Vac/Vdc|**A**|**XTCERENCOILMA**|
|250–500V 40–60|**C**|**XTCERENCOILMC**|
|24–48 Vdc|**TD**|**XTCERENCOILMTD**|
|48–110 Vac/Vdc|**Y**|**XTCERENCOILMY**|
## **Replacement Coil—Frame M, S-Series**
||||**Coil**||
|---|---|---|---|---|
|**Voltage**|||**Suffix**|**Catalog Number**|
|110–120V|50/60|Hz|**A**|**XTCSRENCOILMA**|
|220–240V|50/60|Hz|**B**|**XTCSRENCOILMB**|
## **Replacement Coil—Frame N**[1]
||**Coil**||
|---|---|---|
|**Voltage**|**Suffix**|**Catalog Number**|
|110–250 Vac/Vdc|**A**|**XTCERENCOILNA**|
|250–500V 40–60|**C**|**XTCERENCOILNC**|
|48–110 Vac/Vdc|**Y**|**XTCERENCOILNY**|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-77**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Technical Data and Specifications**
_**XT**_ **Contactors—Frame B**
|**_XT_Contactors—Frame B**|||||
|---|---|---|---|---|
|**Description**|**XTCE007B**|**XTCE009B**|**XTCE012B**|**XTCE015B**|
|**General**|||||
|Standards|IEC/EN 60947, VDE 0660,|IEC/EN 60947, VDE 0660,|IEC/EN 60947, VDE 0660,|IEC/EN 60947, VDE 0660,|
|Weights in kg [lb]|UL, CSA, CCC, RoHS|UL, CSA, CCC, RoHS|UL, CSA, CCC, RoHS|UL, CSA, CCC, RoHS|
|AC operated|0.23 [0.51]|0.23 [0.51]|0.23 [0.51]|0.23 [0.51]|
|DC operated|0.28 [0.62]|0.28 [0.62]|0.28 [0.62]|0.28 [0.62]|
|Mechanical life—operations|10,000,000|10,000,000|10,000,000|10,000,000|
|Mechanical operating frequency (ops/hr)|||||
|AC operated|9000|9000|9000|5000|
|DC operated<br>Electrical life|9000<br>See Curves,|9000<br>See Curves,|9000<br>See Curves,|5000<br>See Curves,|
|Electrical operating frequency (ops/hr)—see Curves,**Page V5-T1-111**|**Page V5-T1-111**|**Page V5-T1-111**|**Page V5-T1-111**|**Page V5-T1-111**|
|AC-1; 400V Ie<br>AC-3; 400V Ie|800<br>1000|800<br>1000|800<br>1000|800<br>1000|
|AC-4; 400V Ie|300|300|300|300|
|Climatic proofing|3|3|3|3|
|Insulation voltage (Ui) Vac|690|690|690|690|
|Impulse withstand voltage (Uimp) Vac<br>Operational voltage (Ue) Vac|8000<br>690|8000<br>690|8000<br>690|8000<br>690|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1<br>Between coil and contacts (Vac)|400|400|400|400|
|Between contacts (Vac)|400|400|400|400|
|Making capacity up to 690V (amps)1|112|112|144|155|
|Breaking capacity (amps)|||||
|220/230V|70|90|120|124|
|380/400V|70|90|120|124|
|500V<br>660/690V|50<br>40|70<br>50|100<br>70|100<br>70|
|Short-circuit protection rating maximum fuse|||||
|Type 2 coordination2|||||
|400V; gG/gL 500V|20|20|20|20|
|690V; gG/gL 690V|16|16|20|20|
|Type 1 coordination2|||||
|400V; gG/gL 500V<br>690V; gG/gL 690V|35<br>20|35<br>20|35<br>20|63<br>50|
|Degree of protection<br>Protection against direct contact when actuated from front (IEC 536)|IP20<br>Finger and|IP20<br>Finger and|IP20<br>Finger and|IP20<br>Finger and|
|Terminal capacity main cable—screw terminals|back-of-hand proof|back-of-hand proof|back-of-hand proof|back-of-hand proof|
|Solid (mm2)|1 x (0.75–4)<br>2 x (0.75–2.5)|1 x (0.75–4)<br>2 x (0.75–2.5)|1 x (0.75–4)<br>2 x (0.75–2.5)|1 x (0.75–4)<br>2 x (0.75–2.5)|
|Flexible with ferrule (mm2)|1 x (0.75–2.5)<br>1 x (0.75–2.5)|1 x (0.75–2.5)<br>1 x (0.75–2.5)|1 x (0.75–2.5)<br>1 x (0.75–2.5)|1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Solid or stranded (AWG)<br>Terminal capacity control circuit cable—screw terminals|18–14|18–14|18–14|18–14|
|Solid (mm2)|1 x (0.75–4)<br>2 x (0.75–2.5)|1 x (0.75–4)<br>2 x (0.75–2.5)|1 x (0.75–4)<br>2 x (0.75–2.5)|1 x (0.75–4)<br>2 x (0.75–2.5)|
## _**Notes**_
> 1 Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.
- 2 IEC 60947 Standard.
- 3 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-78**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
||||||
|---|---|---|---|---|
|**XT Contactors—Frame B, continued**<br>**Description**<br>**XTCE007B**||**XTCE009B**||**XTCE012B**<br>**XTCE015B**|
|**General, continued**|||||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Solid or stranded (AWG)<br>18–14||18–14||18–14<br>18–14|
|Main cable and control circuit cable connection screw/bolt<br>M3.5||M3.5||M3.5<br>M3.5|
|Tightening torque<br>Nm<br>1.2||1.2||1.2<br>1.2|
|Lb-in<br>10.6||10.6||10.6<br>10.6|
|Tools<br>Main and control circuit cable—screw terminals<br>Size 2||Size 2||Size 2<br>Size 2|
|Pozidriv screwdriver<br>0.8 x 5.5||0.8 x 5.5||0.8 x 5.<br>0.8 x 5.5|
|Standard screwdriver<br>1 x 6||1 x 6||1 x 6<br>1 x 6|
|Terminal capacity main circuit cable—spring cage terminals<br>Solid (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Flexible (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Solid or stranded (AWG)<br>18–14||18–14||18–14<br>18–14|
|Terminal capacity control circuit cable—spring cage terminals<br>Solid (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Flexible (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)||1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)<br>1 x (0.75–2.5)|
|Solid or stranded (AWG)<br>18–14||18–14||18–14<br>18–14|
|Tools<br>Main and control circuit cable—spring cage terminals<br>Stripping length (mm)<br>10||10||10<br>10|
|Screwdriver blade width (mm)<br>3.5||3.5||3.5<br>3.5|
|Mounting position, AC and DC operated<br>180°||||30°|
||90°|90°|90°||
||||||
||||||
|Ambient temperature<br>Open<br>–25 to 60°C<br>[–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]|
|Enclosed<br>–25 to 40°C<br>[–13 to 104°F]||–25 to 40°C<br>[–13 to 104°F]||–25 to 40°C<br>[–13 to 104°F]<br>–25 to 40°C<br>[–13 to 104°F]|
|Ambient storage temperature<br>–40 to 80°C<br>[–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]|
|**Environmental**|||||
|Mechanical shock resistance (IEC/EN 60068-2-27)<br>Half-sinusoidal shock 10 ms<br>Main contact—NO contact<br>10g||10g||10g<br>10g|
|Auxiliary contact—NO contact<br>7g||7g||7g<br>7g|
|Auxiliary contact—NC contact<br>5g||5g||5g<br>5g|
|Overvoltage category/pollution degree<br>III/3||III/3||III/3<br>III/3|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-79**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
_**XT**_ **Contactors—Frames C–D**
|**_XT_Contactors—Frames C–D**|||||||
|---|---|---|---|---|---|---|
|**Description**|**XTCE018C**|**XTCE025C**|**XTCE032C**|**XTCE040D**|**XTCE050D**|**XTCE065D, XTCE072D**|
|**General**|||||||
|Standards|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|
||VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|
|Weights in kg [lb]|||||||
|AC operated|0.42 [0.93]|0.42 [0.93]|0.42 [0.93]|0.9 [2.0]|0.9 [2.0]|0.9 [2.0]|
|DC operated|0.48 [1.06]|0.48 [1.06]|0.48 [1.06]|1.1 [2.4]|1.1 [2.4]|1.1 [2.4]|
|Mechanical life—operations|10,000,000|10,000,000|10,000,000|10,000,000|10,000,000|10,000,000|
|Mechanical operating frequency (ops/hr)|||||||
|AC operated<br>DC operated|5000<br>5000|5000<br>5000|5000<br>5000|5000<br>5000|5000<br>5000|5000<br>5000|
|Electrical mechanical operating frequency (ops/hr)—<br>see Curves,**Page V5-T1-111**|||||||
|AC-1; 400V Ie|800|800|800|800|800|800|
|AC-3; 400V Ie|800|800|800|800|800|800|
|AC-4; 400V Ie|300|300|300|300|300|300|
|Climatic proofing|2|2|2|2|2|2|
|Insulation voltage (Ui) Vac|690|690|690|690|690|690|
|Impulse withstand voltage (Uimp) Vac<br>Operating voltage (Ue) Vac|8000<br>690|8000<br>690|8000<br>690|8000<br>690|8000<br>690|8000<br>690|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1|||||||
|Between coil and contacts (Vac)|440|440|440|440|440|440|
|Between contacts (Vac)|238|440|440|440|440|440|
|Making capacity (amps)<br>Breaking capacity (amps)|238|350|384|560|700|910|
|220/230V|170|250|320|400|500|650|
|380/400V|170|250|320|400|500|650|
|500V|170|250|320|400|500|650|
|660/690V|120|150|180|250|320|370|
|Short-circuit protection rating maximum fuse (amps)|||||||
|Type 2 coordination1<br>400V; gG/gL 500V|25|35|63|63|80|125|
|690V; gG/gL 690V|25|35|35|50|63|80|
|Type 1 coordination1|||||||
|400V; gG/gL 500V|63|100|125|125|160|250|
|690V; gG/gL 690V|50|50|63|80|80|100|
|Degree of protection|IP00|IP00|IP00|IP00|IP00|IP00|
|Protection against direct contact when<br>actuated from front (IEC 536)|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|
|Terminal capacity main cable—screw terminals<br>Solid (mm2)|1 x (0.75–16)|1 x (0.75–16)|1 x (0.75–16)|1 x (0.75–16)|1 x (0.75–16)|1 x (0.75–16)|
|Flexible with ferrule (mm2)|2 x (0.75–10)<br>1 x (0.75–16)|2 x (0.75–10)<br>1 x (0.75–16)|2 x (0.75–10)<br>1 x (0.75–16)|2 x (0.75–10)<br>1 x (2.5–35)|2 x (0.75–10)<br>1 x (2.5–35)|2 x (0.75–10)<br>1 x (2.5–35)|
||2 x (0.75–10)|2 x (0.75–10)|2 x (0.75–10)|2 x (2.5–25)|2 x (2.5–25)|2 x (2.5–25)|
|Stranded (mm2)|1 x 16|1 x 16|1 x 16|1 x (16–50)|1 x (16–50)|1 x (16–50)|
|||||2 x (16–35)|2 x (16–35)|2 x (16–35)|
|Solid or stranded (AWG)|14–8|14–8|14–8|14–1|14–1|14–1|
|Flat conductor<br>(number of segments x width x thickness) (mm)|—|—|—|2 x (6 x 9 x 0.8)|2 x (6 x 9 x 0.8)|2 x (6 x 9 x 0.8)|
## _**Notes**_
> 1 IEC 60947 Standard.
> 2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-80**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
||||||||
|---|---|---|---|---|---|---|
|**_XT_Contactors—Frames C–D, continued**<br>**Description**<br>**XTCE018C**||**XTCE025C**<br>**XTCE032C**<br>**XTCE040D**|||**XTCE050D**<br>**XTCE065D, XTCE072D**||
|**General, continued**|||||||
|Main cable connection screw/bolt<br>M5||M5<br>M5<br>M6|||M6<br>M6||
|Tightening torque<br>Nm<br>3||3<br>3<br>3.3|||3.3<br>3.3||
|Lb-in<br>26.6||26.6<br>26.6<br>29.2|||29.2<br>29.2||
|Terminal capacity control circuit cable—screw terminals<br>Solid (mm2)<br>1 x (0.75–4)<br>2 x (0.75–4)||1 x (0.75–4)<br>2 x (0.75–4)<br>1 x (0.75–4)<br>2 x (0.75–4)<br>1 x (0.75–4)<br>2 x (0.75–4)|||1 x (0.75–4)<br>2 x (0.75–4)<br>1 x (0.75–4)<br>2 x (0.75–4)||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Solid or stranded (AWG)<br>18–14||18–14<br>18–14<br>18–14|||18–14<br>18–14||
|Control circuit cable connection screw/bolt<br>M3.5||M3.5<br>M3.5<br>M3.5|||M3.5<br>M3.5||
|Tightening torque<br>Nm<br>1.2||1.2<br>1.2<br>1.2|||1.2<br>1.2||
|Lb-in<br>10.6||10.6<br>10.6<br>10.6|||10.6<br>10.6||
|Tools<br>Main and control circuit cable—screw terminals<br>Size 2||Size 2<br>Size 2<br>Size 2|||Size 2<br>Size 2||
|Pozidriv screwdriver<br>0.8 x 5.5||0.8 x 5.5<br>0.8 x 5.5<br>0.8 x 5.5|||0.8 x 5.5<br>0.8 x 5.5||
|Standard screwdriver<br>1 x 6||1 x 6<br>1 x 6<br>1 x 6|||1 x 6<br>1 x 6||
|Terminal capacity control circuit cable—spring cage terminals<br>Solid (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Flexible (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Solid or stranded (AWG)<br>18–14||18–14<br>18–14|18–14||18–14<br>18–14||
|Tools<br>Main and control circuit cable—spring cage terminals<br>Stripping length (mm)<br>10||10<br>10|10||10<br>10||
|Screwdriver blade width (mm)<br>3.5||3.5<br>3.5|3.5||3.5<br>3.5||
|Mounting position, AC and DC operated<br>180°||90°<br>90°|30°<br>180°||90°<br>30°|30°|
||90°|90°||90°|90°||
||||||||
||||||||
|Ambient temperature<br>Open<br>–25 to 60°C<br>[–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]<br>–25 to<br>[–13 t|60°C<br>o 140°F]<br>–25 to 60°C<br>[–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]<br>–25 to<br>[–13 t|60°C<br>o 140°F]|
|Enclosed<br>–25 to 40°C<br>[–13 to 104°F]||–25 to 40°C<br>[–13 to 104°F]<br>–25 to<br>[–13 t|40°C<br>o 104°F]<br>–25 to 40°C<br>[–13 to 104°F]||–25 to 40°C<br>[–13 to 104°F]<br>–25 to<br>[–13 t|40°C<br>o 104°F]|
|Ambient storage temperature<br>–40 to 80°C<br>[–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]<br>–40 to<br>[–40 t|80°C<br>o 176°F]<br>–40 to 80°C<br>[–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]<br>–40 to<br>[–40 t|80°C<br>o 176°F]|
|**Environmental**|||||||
|Mechanical shock resistance<br>(IEC/EN 60068-2-27)<br>Main contact—NO Contact<br>10||10<br>10|10||1<br>1||
|Auxiliary contact—NO Contact<br>7||7<br>7|7||7<br>7||
|Auxiliary contact—NC Contact<br>5||5<br>5|5||5<br>5||
|Overvoltage category/pollution degree<br>III/3||III/3<br>III/3|III/3||III/3<br>III/3||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-81**
1.1
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
**1**
_**XT**_ **Contactors—Frames F–G**
|**_XT_Contactors—Frames F–G**||||||
|---|---|---|---|---|---|
|**Description**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|**General**||||||
|Standards|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|IEC/EN 60947,|
||VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|VDE 0660, UL, CSA,<br>CCC, RoHS|
|Weights in kg [lb]<br>AC operated|2 [4.41]|2 [4.41]|2 [4.41]|2 [4.41]|2 [4.41]|
|DC operated<br>Mechanical life—operations|2.1 [4.63]<br>10,000,000|2.1 [4.63]<br>10,000,000|2.1 [4.63]<br>10,000,000|2.1 [4.63]<br>10,000,000|2.1 [4.63]<br>10,000,000|
|Mechanical operating frequency (ops/hr)<br>AC operated|3600|3600|3600|3600|3600|
|DC operated|3600|3600|3600|3600|3600|
|Electrical mechanical operating frequency (ops/hr)—||||||
|see Curves,**Page V5-T1-111**<br>AC-1; 400V Ie|800|800|800|800|800|
|AC-3; 400V Ie|800|800|800|800|800|
|AC-4; 400V Ie|300|300|300|300|300|
|Climatic proofing|2|2|2|2|2|
|Insulation voltage (Ui) Vac|690|690|690|690|690|
|Impulse withstand voltage (Uimp) Vac|8000|8000|8000|8000|8000|
|Operational voltage (Ue) Vac|690|690|690|690|690|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1||||||
|Between coil and contacts (Vac)|690|690|690|690|690|
|Between contacts (Vac)|690|690|690|690|690|
|Making capacity (amps)<br>Breaking capacity (amps)|1120|1330|1610|2100|2100|
|220/230V<br>380/400V|800<br>800|950<br>950|1150<br>1150|1500<br>1500|1500<br>1500|
|500V<br>660/690V|800<br>650|950<br>800|1150<br>1100|1500<br>1200|1500<br>1320|
|1000V|—|—|—|—|—|
|Short-circuit protection rating maximum fuse||||||
|Type 2 coordination1||||||
|400V; gG/gL 500V|160|160|250|25|400|
|690V; gG/gL 690V|160|160|25|250|25|
|Type 1 coordination1||||||
|400V; gG/gL 500V|250|25|250|250|400|
|690V; gG/gL 690V|200|200|250|250|250|
|Degree of protection|IP00|IP00|IP00|IP00|IP00|
|Protection against direct contact when actuated from front (IEC 536)|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|Finger and<br>back-of-hand proof|
|Terminal capacity main cable—screw terminals||||||
|Solid (mm2)|—|—|—|—|—|
|Flexible with ferrule (mm2)|1 x (10–95)|1 x (10–95)|1 x (10–95)|1 x (10–95)|1 x (10–95)|
||2 x (10–70)|2 x (10–70)|2 x (10–70)|2 x (10–70)|2 x (10–70)|
|Stranded (mm2)|1 x (16–95)|1 x (16–95)|1 x (16–95)|1 x (16–95)|1 x (16–95)|
||2 x (16–70)|2 x (16–70)|2 x (16–70)|2 x (16–70)|2 x (16–70)|
|Flat conductor|2 x (6 x 16 x 0.8)|2 x (6 x 16 x 0.8)|2 x (6 x 16 x 0.8)|2 x (6 x 16 x 0.8)|2 x (6 x 16 x 0.8)|
|(number of segments x width x thickness) (mm)<br>Solid or stranded (AWG)|8–3/0|8–3/0|8–3/0|8–3/0|8–3/0|
|Main cable connection screw/bolt|M10|M10|M10|M10|M10|
|Tightening torque||||||
|Nm|14|14|14|14|14|
|Lb-in|123.9|123.9|123.9|123.9|123.9|
## _**Notes**_
> 1 IEC 60947 Standard.
> 2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-82**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
_**XT**_ **Contactors—Frames F–G, continued**
|**_XT_Contactors—Frames F–G, continued**|**_XT_Contactors—Frames F–G, continued**||||||
|---|---|---|---|---|---|---|
|**Description**<br>**XTCE080F**||**XTCE095F**|**XTCE115G**||**XTCE150G**<br>**XTCE170G**||
|**General, continued**|||||||
|Terminal capacity control circuit cable—screw terminals<br>Solid (mm2)<br>1 x (0.75–4)<br>1 x (0.75–4)||1 x (0.75–4)<br>1 x (0.75–4)|1 x (0.75–4)<br>1 x (0.75–4)||1 x (0.75–4)<br>1 x (0.75–4)<br>1 x (0.75–4)<br>1 x (0.75–4)||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)|1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Solid or stranded (AWG)<br>18–14||18–14|18–14||18–14<br>18–14||
|Control circuit cable connection screw/bolt<br>M3.5||M3.5|M3.5||M3.5<br>M3.5||
|Tightening torque<br>Nm<br>1.2||1.2|1.2||1.2<br>1.2||
|Lb-in<br>10.6||10.6|10.6||10.6<br>10.6||
|Tools<br>Main circuit cable—screw terminals<br>Hexagon socket-head spanner (mm)<br>5||5|5||5<br>5||
|Control circuit cable—screw terminals<br>Pozidriv screwdriver<br>Size 2||Size 2|Size 2||Size 2<br>Size 2||
|Standard screwdriver<br>1 x 6, 0.8 x 5.5||1 x 6, 0.8 x 5.5|1 x 6, 0.8 x 5.5||1 x 6, 0.8 x 5.5<br>1 x 6, 0.8 x 5.5||
|Terminal capacity control circuit cable—spring cage terminals<br>Solid (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)|1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Flexible (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)|1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)|1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Solid or stranded (AWG)<br>18–14||18–14|18–14||18–14<br>18–14||
|Tools<br>Control circuit cable—spring cage terminals<br>Stripping length (mm)<br>10||10|10||10<br>10||
|Screwdriver blade width (mm)<br>3.5||3.5|3.5||3.5<br>3.5||
|Mounting position, AC and DC operated<br>180°||90°<br>30°|30°<br>180°||90°<br>30°|30°|
||90°|90°||90°|90°||
||||||||
||||||||
|Ambient temperature<br>Open<br>–25 to 60°C<br>[–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]|–25 to 60°C<br>[–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]||
|Enclosed<br>–25 to 40°C<br>[–13 to 104°F]||–25 to 40°C<br>[–13 to 104°F]|–25 to 40°C<br>[–13 to 104°F]||–25 to 40°C<br>[–13 to 104°F]<br>–25 to 40°C<br>[–13 to 104°F]||
|Ambient storage temperature<br>–40 to 80°C<br>[–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]|–40 to 80°C<br>[–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]||
|**Environmental**|||||||
|Mechanical shock resistance<br>(IEC/EN 60068-2-27)<br>Half-sinusoidal shock 10 ms<br>Main contact—NO contact<br>10g||10g|10g||10g<br>10g||
|Auxiliary contact—NO contact<br>7g||7g|7g||7g<br>7g||
|Auxiliary contact—NC contact<br>5g||5g|5g||5g<br>5g||
|Overvoltage category/pollution degree<br>III/3||III/3|III/3||III/3<br>III/3||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-83**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**XT**_ **Contactors—Frames H–M**
|**_XT_Contactors—Frames H–M**||||||||
|---|---|---|---|---|---|---|---|
||||**XTCE250L,**|**XTCE300L,**|**XTCE400M**|**XTCE500M,**|**XTCE570M**|
|**Description**<br>**General**|**XTCE185H**|**XTCE225H**|**XTCS250L**|**XTCS300L**|**XTCS400M**|**XTCS500M**|**XTCS570M**|
|Standards|IEC/EN 60947,<br>VDE 0660,|IEC/EN 60947,<br>VDE 0660,|IEC/EN 60947,<br>VDE 0660,|IEC/EN 60947,<br>VDE 0660,|IEC/EN 60947,<br>VDE 0660,|IEC/EN 60947,<br>VDE 0660,|IEC/EN 60947,<br>VDE 0660,|
||UL, CSA|UL, CSA|UL, CSA|UL, CSA|UL, CSA|UL, CSA|UL, CSA|
|Weights in kg [lb]|3.2 [7.1]|3.2 [7.1]|6.5 [14.3]|6.5 [14.3]|8 [18]|8 [18]|8 [18]|
|Mechanical life—operations<br>Mechanical operating frequency (ops/hr)|10,000,000|10,000,000|10,000,000|10,000,000|7,000,000|7,000,000|7,000,000|
|AC operated|3000|3000|3000|3000|2000|2000|2000|
|DC operated|3000|3000|3000|3000|2000|2000|2000|
|Mechanical operating frequency (ops/hr)||||See**Page V5-T1-93**||||
|Climatic proofing|2|2|2|2|2|2|2|
|Insulation voltage (Ui) Vac|1000|1000|1000|1000|1000|1000|1000|
|Impulse withstand voltage (Uimp) Vac<br>Operating voltage (Ue) Vac|8000<br>1000|8000<br>1000|8000<br>1000|8000<br>1000|8000<br>1000|8000<br>1000|8000<br>1000|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1<br>Between coil and contacts (Vac)|500|500|500|500|500|500|500|
|Between contacts (Vac)|500|500|500|500|500|500|500|
|Making capacity (amps)|2700|2700|3000|3600|5500|5500|5500|
|Breaking capacity (amps)||||||||
|Between coil and contacts (Vac)||||||||
|220/230V|2250|2250|2500|3000|5000|5000|5000|
|380/400V|2250|2250|2500|3000|5000|5000|5000|
|500V|2250|2250|2500|3000|5000|5000|5000|
|660/690V<br>1000V|2250<br>760|2250<br>760|2500<br>760|3000<br>950|5000<br>950|5000<br>950|5000<br>950|
|Short-circuit protection rating maximum fuse<br>Type 2 coordination1||||||||
|400V; gG/gL 500V|315|315|315|315|500|500|500|
|690V; gG/gL 690V|250|250|315|315|500|500|500|
|1000V; gG/gL 1000V|160|160|160|160|200|200|200|
|Degree of protection|IP00|IP00|IP00|IP00|IP00|IP00|IP00|
|Protection against direct contact when|||Finger and back-of-hand proof with terminal shroud or terminal|||block||
|actuated from front (IEC 536)||||||||
|Main cable cross-section||||||||
|Flexible with cable lug (mm2)|50–185|50–185|50–240|50–240|50–240|50–240|50–240|
|Stranded with cable lug (mm2)|50–185|70–185|70–240|70–240|70–240|70–240|70–240|
|Solid or stranded (AWG)<br>Flat conductor (mm)|1/0–350 kcmil<br>3|2/0–250 kcmil<br>3|1/0–250 kcmil<br>3|2/0–500 kcmil<br>3|1/0–250 kcmil<br>3|1/0–250 kcmil<br>3|1/0–250 kcmil<br>3|
|Busbar—width in mm|32|32|25|25|25|30|30|
|Main cable connection screw/bolt|M10|M10|M10|M10|M10|M10|M10|
|Tightening torque<br>Nm|24|24|24|24|2|2|2|
|Lb-in|213|213|213|213|213|213|213|
## _**Notes**_
> 1 IEC 60947 Standard.
> 2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
> 3 Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-84**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
_**XT**_ **Contactors—Frames H–M, continued**
|**_XT_Contactors—Frames H–M, continued**|**_XT_Contactors—Frames H–M, continued**|**_XT_Contactors—Frames H–M, continued**|**_XT_Contactors—Frames H–M, continued**|**_XT_Contactors—Frames H–M, continued**|||||
|---|---|---|---|---|---|---|---|---|
|**Description**<br>**XTCE185H**<br>**XTCE225H**<br>**XTCE250L,**<br>**XTCS250L**<br>**XTCE300L,**<br>**XTCS300L**<br>**XTCE400M**<br>**XTCS400M**<br><br>|||||**XTCE500M,**<br>**XTCS500M**||**XTCE570M**<br>**XTCS570M**||
|**General, continued**|||||||||
|Control circuit cable cross-sections<br>Solid (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br> <br>|||||1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br> <br>|||||1 x (0.75–2.5)<br>2 x (0.75–2.5)||1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Solid or stranded (AWG)<br>2 x (18–12)||2 x (18–12)<br>2 x (18–12)||2 x (18–12)<br>2 x (18–12)<br>|2 x (18–12)||2 x (18–12)||
|Control circuit cable connection screw/bolt<br>M3.5<br>Tightening torque<br>Nm<br>1.2||M3.5<br>M3.5<br>1.2<br>1.2||M3.5<br>M3.5<br><br>1.2<br>1.2<br>|M3.5<br>1.2||M3.5<br>1.2||
|Lb-in<br>10.6||10.6<br>10.6||10.6<br>10.6<br>|10.6||10.6||
|Tools<br>Main cable wrench<br>16 mm||16 mm<br>16 mm||16 mm<br>16 mm<br>|16 mm||16 mm||
|Control circuit cable pozidriv screwdriver<br>Size 2||Size 2<br>Size 2||Size 2<br>Size 2<br>|Size 2||Size 2||
|Mounting position, AC and DC operated<br>180°|90°|90°|30°|30°|90°||90°<br>30°|30°|
||||||||||
||||||||||
||||||||||
|Ambient temperature<br>–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]<br> <br>[|||||–25 to 60°C<br>–13 to 140°F]||–25 to 60°C<br>[–13 to 140°F]||
|Ambient storage temperature<br>–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]<br> <br>[|||||–40 to 80°C<br>–40 to 176°F]||–40 to 80°C<br>[–40 to 176°F]||
|**Environmental**|||||||||
|Mechanical shock<br>Resistance (IEC/EN 60068-2-27)<br>Half-sinusoidal shock 10 ms<br>Main contact—NO contact<br>10g<br>10g<br>10g<br>10g<br>10g<br>|||||10g||10g||
|Auxiliary contact—NO contact<br>10g<br>10g<br>10g<br>10g<br>10g<br>|||||10g||10g||
|Auxiliary contact—NC contact<br>8g<br>8g<br>8g<br>8g<br>8g<br>|||||8g||8g||
|Overvoltage category/pollution degree<br>III/3<br>III/3<br>III/3<br>III/3<br>III/3<br>I|||||II/3||III/3||
|Switching capacity, kVAR1<br>Individual compensation<br>230V<br>—<br>—<br>—<br>—<br>—<br>|||||—||—||
|400/420/440V<br>—<br>—<br>—<br>—<br>—<br>|||||—||—||
|525V<br>220<br>220<br>—<br>307<br>—<br>|||||—||—||
|690V<br>133<br>133<br>—<br>177<br>—<br>|||||—||—||
|Group compensation, with choke<br>230V<br>—<br>—<br>100<br>—<br>160<br>|||||160||160||
|400/420/440V<br>—<br>—<br>190<br>—<br>280<br>|||||280||280||
|525V<br>—<br>—<br>260<br>—<br>370<br>|||||370||370||
|690V<br>—<br>—<br>340<br>—<br>480<br>|||||480||480||
## _**Note**_
> 1 When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with five windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-85**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**XT**_ **Contactors—Frames N–R**
|**_XT_Contactors—Frames N–R**|||||||
|---|---|---|---|---|---|---|
||||**XTCE750N,**|||**XTCEC16R,**|
|**Description**<br>**General**|**XTCE580N**|**XTCE650N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC20R**|
|Standards|IEC/EN 60947,<br>VDE 0660, UL, CSA|IEC/EN 60947,<br>VDE 0660, UL, CSA|IEC/EN 60947,<br>VDE 0660, UL, CSA|IEC/EN 60947,<br>VDE 0660, UL, CSA|IEC/EN 60947,<br>VDE 0660, UL, CSA|IEC/EN 60947,<br>VDE 0660, UL, CSA|
|Weights in kg [lb]|15 [33]|15 [33]|15 [33]|15 [33]|15, [33]|32 [70]|
|Mechanical life—operations|5,000,000|5,000,000|5,000,000|5,000,000|5,000,000|5,000,000|
|Mechanical operating frequency (ops/hr)|||||||
|AC operated|1000|1000|1000|1000|1000|1000|
|DC operated|1000|1000|1000|1000|1000|1000|
|Maximum operating frequency (ops/hr)<br>Climatic proofing|2|2|See**Page**<br>2|**V5-T1-113**<br>2|2|2|
|Insulation voltage (Ui) Vac|1000|1000|1000|1000|1000|1000|
|Impulse withstand voltage (Uimp) Vac|8000|8000|8000|8000|8000|8000|
|Operating voltage (Ue) Vac|1000|1000|1000|1000|1000|1000|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1|||||||
|Between coil and contacts (Vac)|500|500|500|500|500|500|
|Between contacts (Vac)<br>Making capacity (amps)|500<br>7800|500<br>7800|500<br>9840|500<br>9840|500<br>9840|500<br>19000, 9840|
|Breaking capacity (amps)|||||||
|220/230V|6500|6500|8200|8200|8200|16000, 8200|
|380/400V|6500|6500|8200|8200|8200|16000, 8200|
|500V|6500|6500|8200|8200|8200|16000, 8200|
|660/690V|6500|6500|8200|8200|8200|16000, 8200|
|1000V<br>Short-circuit protection rating maximum fuse|4350|4350|5800|5800|5800|5800|
|Type 2 coordination1|||||||
|400V; gG/gL 500V|630|630|630|630|—|—|
|690V; gG/gL 690V|630|630|630|630|—|—|
|1000V; gG/gL 1000V|500|500|630|630|—|—|
|Type 1 coordination1|||||||
|400V; gG/gL 500V<br>690V; gG/gL 690V|1000<br>1000|1000<br>1000|1200<br>1200|1200<br>1200|—<br>—|—<br>—|
|1000V; gG/gL 1000V|630|630|800|800|—|—|
|Degree of protection|IP00|IP00|IP00|IP00|IP00|IP00|
|Protection against direct contact when actuated<br>from front (IEC 536)|Finger and back-of-<br>hand proof with|Finger and back-of-<br>hand proof with|Finger and back-of-<br>hand proof with|Finger and back-of-<br>hand proof with|Finger and back-of-<br>hand proof with|Finger and back-of-<br>hand proof with|
||terminal shroud or<br>terminal block|terminal shroud or<br>terminal block|terminal shroud or<br>terminal block|terminal shroud or<br>terminal block|terminal shroud or<br>terminal block|terminal shroud or<br>terminal block|
|Main cable cross-section|||||||
|Flexible with cable lug (mm2)|50-240|50-240|50-240|50-240|50-240|50-240|
|Stranded with cable lug (mm2)|70-240|70-240|70-240|70-240|70-240|70-240|
|Solid or stranded (AWG)|2/0–500 kcmil|2/0–500 kcmil|2/0–500 kcmil|2/0–500 kcmil|2/0–500 kcmil|2/0–500 kcmil|
|Flat conductor (mm)|3|3|3|3|3|3|
|Busbar—width in mm|50|50|50|50|50|50|
|Main cable connection screw/bolt|M10|M10|M12|M12|M12|M1|
|Tightening torque<br>Nm|24|24|35|35|35|35|
|Lb-in|213|213|311|311|311|311|
## _**Notes**_
> 1 IEC 60947 Standard.
> 2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
> 3 Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-86**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XT Contactors—Frames N–R, continued**
|**Description**<br>|**XTCE580N**<br>**XTCE650N**<br>**XTCE750N, XTCE820N**<br>**XTCEC10N**<br>**XTCEC14P**<br>**XTCEC16R, XTCEC20R**|**XTCE580N**<br>**XTCE650N**<br>**XTCE750N, XTCE820N**<br>**XTCEC10N**<br>**XTCEC14P**<br>**XTCEC16R, XTCEC20R**|**XTCE580N**<br>**XTCE650N**<br>**XTCE750N, XTCE820N**<br>**XTCEC10N**<br>**XTCEC14P**<br>**XTCEC16R, XTCEC20R**|**XTCE580N**<br>**XTCE650N**<br>**XTCE750N, XTCE820N**<br>**XTCEC10N**<br>**XTCEC14P**<br>**XTCEC16R, XTCEC20R**|
|---|---|---|---|---|
|**General, continued**|||||
|Control circuit cable cross-sections<br>Solid (mm2)<br> <br>|1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|
|Flexible with ferrule (mm2)<br> <br>|1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)|
|Solid or stranded (AWG)<br>|2 x (18–12)|2 x (18–12)<br>2 x (18–12)||2 x (18–12)<br>2 x (18–12)<br>2 x (18–12)|
|Control circuit cable connection screw/bolt<br><br>Tightening torque<br>Nm<br>|M3.5<br>1.2|M3.5<br>M3.5<br>1.2<br>1.2||M3.5<br>M3.5<br>M3.5<br>1.2<br>1.2<br>1.2|
|Lb-in<br>|10.6|10.6<br>10.6||10.6<br>10.6<br>10.6|
|Tools<br>Main cable wrench<br>|16 mm|16 mm<br>18 mm||18 mm<br>18 mm<br>18 mm|
|Control circuit cable pozidriv screwdriver<br>|Size 2|Size 2<br>Size 2||Size 2<br>Size 2<br>Size 2|
|Mounting position, AC and DC operated|||30°<br>90°|30°|
||90°||90°||
||||||
||||||
||||||
|Ambient temperature<br> <br>[|–25 to 60°C<br>–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]|||–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]<br>–25 to 60°C<br>[–13 to 140°F]|
|Ambient storage temperature<br> <br>[|–40 to 80°C<br>–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]|||–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]<br>–40 to 80°C<br>[–40 to 176°F]|
|**Environmental**|||||
|Mechanical shock resistance (IEC/EN 60068-2-27)<br>Half-sinusoidal shock 10 ms (g)<br>Main contact—NO contact<br>|10<br>10<br>10|||10<br>10<br>10|
|Auxiliary contact—NO contact<br>|10<br>10<br>10|||10<br>10<br>10|
|Auxiliary contact—NC contact<br>|8<br>8<br>8|||8<br>8<br>8|
|Overvoltage category/pollution degree<br>I|II/3<br>III/3<br>III/3|||III/3<br>III/3<br>III/3|
|Switching capacity, kVAR1<br>Individual compensation<br>230V<br>|175<br>—<br>—|||—<br>—<br>—|
|400/420/440V<br>|300<br>—<br>—|||—<br>—<br>—|
|525V<br>|400<br>—<br>—|||—<br>—<br>—|
|690V<br>|300<br>—<br>—|||—<br>—<br>—|
## _**Note**_
> 1 When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with five windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-87**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Coil Data—Frames B–D**
||||**XTCE012B,**|||||||**XTCE065D,**|
|---|---|---|---|---|---|---|---|---|---|---|
|**Description**<br>**Voltage Tolerance**|**XTCE007B**|**XTCE009B**|**XTCF020B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|**XTCE040D**|**XTCE050D**|**XTCE072D**|
|Pickup (x Uc)|||||||||||
|AC operated|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|
|DC operated|0.8–1.11|0.8–1.11|0.8–1.11|0.8–1.11|0.7–1.22|0.7–1.22|0.7–1.22|0.7–1.22|0.7–1.22|0.7–1.22|
|Dropout (x Uc)<br>AC operated|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|0.3–0.6|
|DC operated|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|
|**Power Consumption of the Coil at**||**Cold State and 1.0 x Uc**|||||||||
|AC operated<br>Single-voltage coil 50 Hz|||||||||||
|Pickup VA|24|24|24|24|52|52|52|149|149|149|
|Pickup W|19|19|19|19|40|40|40|80|80|80|
|Sealing VA|3.4|3.4|3.4|3.4|7.1|7.1|7.1|16|16|16|
|Sealing W<br>Single-voltage coil 60 Hz|1.2|1.2|1.2|1.2|2.1|2.1|2.1|4.3|4.3|4.3|
|Pickup VA|30|30|30|30|67|67|67|178|178|178|
|Pickup W|23|23|23|23|50|50|50|117|117|117|
|Sealing VA|4.4|4.4|4.4|4.4|8.7|8.7|8.7|19|19|19|
|Sealing W|1.4|1.4|1.4|1.4|2.6|2.6|2.6|5.3|5.3|5.3|
|50/60 Hz|||||||||||
|Pickup VA|27<br>25|27<br>25|27<br>25|27<br>25|62<br>58|62<br>58|62<br>58|168<br>154|168<br>154|168<br>154|
|Pickup W|22<br>21|22<br>21|22<br>21|22<br>21|48<br>43|48<br>43|48<br>43|120<br>43|120<br>43|120<br>43|
|Sealing VA|4.2|4.2|4.2|4.2|9.1|9.1|9.1|22|22|22|
||3.3|3.3|3.3|3.3|6.5|6.5|6.5|14|14|14|
|Sealing W|1.4|1.4|1.4|1.4|2.5|2.5|2.5|5.3|5.3|5.3|
||1.2|1.2|1.2|1.2|2|2|2|4.3|4.3|4.3|
|DC operated|||||||||||
|Pickup W|3|3|4.5|4.5|12 at 24V|12 at 24V|12 at 24V|24 at 24V|24 at 24V|24 at 24V|
|Sealing W<br>Duty factor (%DF)|3<br>100|3<br>100|4.5<br>100|4.5<br>100|0.5 at 24V<br>100|0.5 at 24V<br>100|0.5 at 24V<br>100|0.5 at 24V<br>100|0.5 at 24V<br>100|0.5 at 24V<br>100|
|**Switching Time at 100% Uc (Approximate Values)**|||||||||||
|Main contact|||||||||||
|AC operated|||||||||||
|Closing delay (ms)|<21|<21|<21|<21|<22|<22|<22|<18|<18|<18|
|Opening delay (ms)|<18|<18|<18|<18|<14|<14|<14|<13|<13|<13|
|DC operated<br>Closing delay (ms)|<31|<31|<31|<31|<47|<47|<47|<54|<54|<54|
|Opening delay (ms)|<12|<12|<12|<12|<30|<30|<30|<24|<24|<24|
|Arcing time (ms)|10|10|10|10|10|10|10|10|10|10|
|**Electromagnetic Compatibility (EMC)**|||||||||||
|Emitted interference|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|
|Noise immunity|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|To EN-60947-1|
## _**Notes**_
> 1 0.7–1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F].
> 2 Coil Suffix TD: Umin 24 Vdc/Umax 27 Vdc. Coil Suffix WD: Umin 48 Vdc/Umax 60 Vdc. Coil Suffix AD: Umin 110 Vdc/Umax 130 Vdc. Coil Suffix BD: Umin 200 Vdc/Umax 240 Vdc. Example:
Uc = 0.7 x Umin—1.2 x Umax
Uc = 0.7 x 24V—1.2 x 27 Vdc
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-88**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Coil Data—Frames F–G**
|**Coil Data—Frames F–G**||||||
|---|---|---|---|---|---|
|**Description**|**XTCE80F**|**XTCE95F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|**Voltage Tolerance**||||||
|Pickup (x Uc)||||||
|AC operated|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|
|DC operated<br>Dropout (x Uc)|0.7–1.21|0.7–1.21|0.7–1.21|0.7–1.21|0.7–1.21|
|AC operated|0.3–0.6|0.3–0.6|0.25–0.6|0.25–0.6|0.25–0.6|
|DC operated|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|0.15–0.6|
|**Power Consumption of the Coil at Cold**|**State and 1.0 x Uc**|||||
|AC operated||||||
|Single-voltage coil 50 Hz||||||
|Pickup VA|310|310|180|180|180|
|Pickup W|165|165|130|130|130|
|Sealing VA<br>Sealing W|26<br>5.8|26<br>5.8|3.1<br>2.1|3.1<br>2.1|3.1<br>2.1|
|Single-voltage coil 60 Hz||||||
|Pickup VA|345|345|170|170|170|
|Pickup W|190|190|130|130|130|
|Sealing VA|30|30|3.1|3.1|3.1|
|Sealing W|7.1|7.1|2.1|2.1|2.1|
|50/60 Hz<br>Pickup VA|372|328|170|170|170|
|Pickup W|190|190|130|130|130|
|Sealing VA|37.1|22.6|3.1|3.1|3.1|
|Sealing W|7.5|6.1|2.1|2.1|2.1|
|DC operated<br>Pickup W|90 at 24V|90 at 24V|149 at 24V|149 at 24V|149 at 24V|
|Sealing W<br>Duty factor (%DF)|1.3 at 24V<br>100|1.3 at 24V<br>100|2.1 at 24V<br>100|2.1 at 24V<br>100|2.1 at 24V<br>100|
|**Switching Time at 100% Uc (Approximate Values)**||||||
|Main contact||||||
|AC operated||||||
|Closing delay (ms)<br>Opening delay (ms)|<20<br><14|<20<br><14|<33<br><41|<33<br><41|<33<br><41|
|DC operated||||||
|Closing delay (ms)|<45|<45|<35|<35|<35|
|Opening delay (ms)|<34|<34|<30|<30|<30|
|Arcing time (ms)|15|15|15|15|15|
|Permissible residual current with actuation of|<<br>~~1~~|<<br>1|<<br>1|<<br>~~1~~|<<br>~~1~~|
|A1–A2 by the electronics (with 0 signal) (mA)||||||
|**Electromagnetic Compatibility (EMC)**||||||
|Emitted interference<br>Noise immunity|To EN60947-1<br>To EN60947-1|To EN60947-1<br>To EN60947-1|To EN60947-1<br>To EN60947-1|To EN60947-1<br>To EN60947-1|To EN60947-1<br>To EN60947-1|
## _**Note**_
> 1 At 24V: 0.7–1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F].
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-89**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Coil Data—Frames H–R**
|||||**XTCE400M, XTCS400M, XTCE500M,**|
|---|---|---|---|---|
|**Description**<br>**Voltage Tolerance**|**XTCE185H, XTCE225H**|**XTCE250L, XTCS250L**|**XTCE300L, XTCS300L**|**XTCS500M, XTCE570M, XTCS570M**|
|Pickup (x Uc)|||||
|XTCE185H–XTCEC20R|0.8 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|
|XTCS250L–XTCS500M|—|0.85 x Ucmin–1.1 x Ucmax|0.85 x Ucmin–1.1 x Ucmax|0.85 x Ucmin–1.1 x Ucmax|
|Dropout (x Uc)|||||
|XTCE185H–XTCEC20R|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|
|XTCS250L–XTCS500M|—|0.2 x Ucmin–0.4 x Ucmax|0.2 x Ucmin–0.4 x Ucmax|0.2 x Ucmin–0.4 x Ucmax|
|**Power Consumption of**|**the Coil at Cold State and 1.0 x**|**Uc**|||
|XTCE185H–XTCEC20R<br>Pickup VA|2101|2501|3801|4501|
|Pickup W|180|200|250|350|
|Sealing VA|2.6|4.3|4.3|4.3|
|Sealing W|2.1|3.3|3.3|3.3|
|XTCS250L–XTCS500M|||||
|Pickup VA|—|360|360|715|
|Pickup W<br>Sealing VA|—<br>—|325<br>4.3|625<br>4.3|645<br>4.3|
|Sealing W|—|3.3|3.3|3.3|
|Duty factor (%DF)|—|100|100|100|
|**Switching Time at 100% Main Contact Uc (Approximate Values)**|||||
|XTCE185H–XTCEC20R|||||
|Closing delay (ms)|<60|<100|<80|<80|
|Opening delay (ms)|<40|<80|<110|<80|
|XTCS250L–XTCS500M|||||
|Closing delay (ms)<br>Opening delay (ms)|—<br>—|<50<br><40|<55<br><40|<50<br><40|
|**Reaction in Threshold and Sealing State Transition Range (XTCE185H–XTCEC20R)**|||||
|Voltage interruptions|||||
|(0–0.2 x Ucmin) <<br>~~1~~0 ms|Time is bridged successfully|Time is bridged successfully|Time is bridged successfully|Time is bridged successfully|
|(0–0.2 x Ucmin) >10 ms|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|
|Voltage dips|||||
|(0.2–0.6 x Ucmin) <<br>~~1~~2 ms|Time is bridged successfully|Time is bridged successfully|Time is bridged successfully|Time is bridged successfully|
|(0.2–0.6 x Ucmin) >12 ms|Contactor remains switched on|Contactor remains switched on|Dropout of the contactor|Contactor remains switched on|
|(0.6–0.7 x Ucmin)<br>Excess voltage|Contactor remains switched on|Contactor remains switched on|Contactor remains switched on|Contactor remains switched on|
|(1.15–1.3 x Ucmax)<br>(>1.3 x Ucmax) <<br>~~3~~s|Contactor remains switched on<br>Contactor remains switched on|Contactor remains switched on<br>Contactor remains switched on|Contactor remains switched on<br>Contactor remains switched on|Contactor remains switched on<br>Contactor remains switched on|
|(>1.3 x Ucmax) >3s|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|
|Pickup phase|||||
|(0–0.7 x Ucmin)|Contactor does not switch on|Contactor does not switch on|Contactor does not switch on|Contactor does not switch on|
|(0.7 x Ucmin–1.15 x Ucmax)|Contactor switches on with certainty|Contactor switches on with certainty|Contactor switches on with certainty|Contactor switches on with certainty|
|(>1.15 x Ucmax)|Contactor switches on with certainty|Contactor switches on with certainty|Contactor switches on with certainty|Contactor switches on with certainty|
_**Note**_
> 1 Control transformer with Uk < ~~6~~ %.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-90**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Coil Data—Frames H–R, continued**
|**Coil Data—Frames H–R, continued**||||
|---|---|---|---|
||||**XTCE400M, XTCS400M,**|
|**Description**|**XTCE185H, XTCE225H**<br>**XTCE250L, XTCS250L**|**XTCE300L, XTCS300L**|**XTCE500M, XTCS500M,**<br>**XTCE570M, XTCS570M**|
|**Reaction in Threshold and Sealing State Transition**<br>Permissible contact resistance (of the external command|**Range (XTCE185H–XTCEC20R), continued**<br>—<br>≤500|≤500|≤500|
|device with actuation of A11), ohms<br>Permissible residual current (with actuation of A11|—<br>≤1|≤1|≤1|
|by the electronics with 0 signal)||||
|SPS signal level (A3–A4) to IEC/EN 61131-2 (Type 2)||||
|High<br>Low|15V<br>15V<br>5V<br>5V|15V<br>5V|15V<br>5V|
|Electromagnetic compatibility (EMC)|This product is designed for operation in industrial environments (environment 2). The use in residential environments<br>(environment 1) could cause electrical interference so that addition suppression must be planned.|||
## **Coil Data—Frames N–R**
|**Coil Data—Frames**|**N–R**|||||
|---|---|---|---|---|---|
|||**XTCE750N,**|||**XTCE16R,**|
|**Description**<br>**Voltage Tolerance**|**XTCE580N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC20R**|
|Pickup (x Uc)||||||
|XTCE185L–XTCEC20R|0.7 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|0.7 x Ucmin–1.15 x Ucmax|
|XTCS185L–XTCS500M|0.85 x Ucmin–1.1 x Ucmax|0.85 x Ucmin–1.1 x Ucmax|0.85 x Ucmin–1.1 x Ucmax|0.85 x Ucmin–1.1 x Ucmax|0.85 x Ucmin–1.1 x Ucmax|
|Dropout (x Uc)<br>XTCE185L–XTCEC20R|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|0.2 x Ucmin–0.6 x Ucmax|
|XTCS185L–XTCS500M|0.2 x Ucmin–0.4 x Ucmax|0.2 x Ucmin–0.4 x Ucmax|0.2 x Ucmin–0.4 x Ucmax|0.2 x Ucmin–0.4 x Ucmax|0.2 x Ucmin–0.4 x Ucmax|
|**Power Consumption of the Coil at Cold State and 1.0 x Uc**||||||
|XTCE185L–XTCEC20R||||||
|Pickup VA|8001|8001|8001|8001|16001|
|Pickup W|700|700|700|700|1400|
|Sealing VA<br>Sealing W|7.5<br>6.5|7.5<br>6.5|7.5<br>6.5|7.5<br>6.5|15<br>13|
|XTCS185L–XTCS500M||||||
|Pickup VA|—|—|—|—|—|
|Pickup W|—|—|—|—|—|
|Sealing VA|—|—|—|—|—|
|Sealing W|—|—|—|—|—|
|Duty factor (%DF)<br>100<br>100<br>**Switching Time at 100% Main Contact Uc (Approximate Values)**|||100|100|100|
|XTCE185L–XTCEC20R||||||
|Closing delay (ms)|<70|<70|<70|<70|<70|
|Opening delay (ms)|<70|<70|<70|<40|<40|
|XTCS185L–XTCS500M||||||
|Closing delay (ms)|—|—|—|—|—|
|Opening delay (ms)|—|—|—|—|—|
_**Note**_
> 1 Control transformer with Uk < ~~7~~ %.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-91**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Coil Data—Frames N–R, continued**
|||**XTCE750N,**|||**XTCE16R,**|
|---|---|---|---|---|---|
|**Description**<br>**Reaction in Threshold and Sealing State**|**XTCE580N**<br>**XTCE820N**<br>**Transition Range (XTCE185L–XTCEC20R)**||**XTCEC10N**|**XTCEC14P**|**XTCEC20R**|
|Voltage interruptions||||||
|(0–0.2 x Ucmin) <<br>~~1~~0 ms|Time is bridged|Time is bridged|Time is bridged|Time is bridged|Time is bridged|
||successfully|successfully|successfully|successfully|successfully|
|(0–0.2 x Ucmin) >10 ms|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|
|Voltage dips||||||
|(0.2–0.6 x Ucmin) <<br>~~1~~2 ms|Time is bridged|Time is bridged|Time is bridged|Time is bridged|Time is bridged|
||successfully|successfully|successfully|successfully|successfully|
|(0.2–0.6 x Ucmin) >12 ms|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|
|(0.6–0.7 x Ucmin)|Contactor remains|Contactor remains|Contactor remains|Contactor remains|Contactor remains|
||switched on|switched on|switched on|switched on|switched on|
|Excess voltage||||||
|(1.15–1.3 x Ucmax)|Contactor remains<br>switched on|Contactor remains<br>switched on|Contactor remains<br>switched on|Contactor remains<br>switched on|Contactor remains<br>switched on|
|(>1.3 x Ucmax) <<br>~~3~~s|Contactor remains<br>switched on|Contactor remains<br>switched on|Contactor remains<br>switched on|Contactor remains<br>switched on|Contactor remains<br>switched on|
|(>1.3 x Ucmax) >3s|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|Dropout of the contactor|
|Pickup phase||||||
|(0–0.7 x Ucmin)|Contactor does not<br>switch on|Contactor does not<br>switch on|Contactor does not<br>switch on|Contactor does not<br>switch on|Contactor does not<br>switch on|
|(0.7 x Ucmin–1.15 x Ucmax)|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|
|(>1.15 x Ucmax)|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|Contactor switches on<br>with certainty|
|Permissible contact resistance (of the external|<<br>~~5~~00|<<br>~~5~~00|<<br>~~5~~00|<<br>~~5~~00|<<br>~~5~~00|
|command device with actuation of A11), ohms||||||
|Permissible residual current (with actuation of A11|<<br>~~1~~|<<br>~~1~~|<<br>~~1~~|<<br>~~1~~|<<br>~~1~~|
|by the electronics with 0 signal)||||||
|SPS signal level (A3–A4) to IEC/EN 61131-2 (Type 2)||||||
|High|15V|15V|15V|15V|15V|
|Low|5V|5V|5V|5V|5V|
|Electromagnetic compatibility (EMC)|1|1|1|1|1|
## _**Note**_
> 1 This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI). Noise suppression measures must be provided for the additional interference.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-92**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**XT**_ **Contactors—Four-Pole**
|**_XT_Contactors—Four-Pole**||
|---|---|
|**Description**|**XTCF020B**<br>**XTCF032C**<br>**XTCF045C**<br>**XTCF063D**<br>**XTCF080D**<br>**XTCF125G**<br>**XTCF160G**<br>**XTCF200G**|
|**General**||
|Standards|IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA<br>IEC/EN 60947,<br>VDE 0660, UL,<br>CSA|
|Weights in kg [lb]<br>AC operated|0.22 [0.49]<br>0.49 [1.1]<br>0.49 [1.1]<br>1.0 [2.3]<br>1.0 [2.3]<br>2.8 [6.2]<br>2.8 [6.2]<br>2.8 [6.2]|
|DC operated|0.29 [0.64]<br>0.49 [1.1]<br>0.49 [1.1]<br>1.0 [2.3]<br>1.0 [2.3]<br>2.8 [6.2]<br>2.8 [6.2]<br>2.8 [6.2]|
|Mechanical life—operations|10,000,000<br>10,000,000<br>10,000,000<br>10,000,000<br>10,000,000<br>10,000,000<br>10,000,000<br>10,000,000|
|Mechanical operating frequency (ops/hr)<br>AC operated|5000<br>5000<br>5000<br>5000<br>5000<br>3600<br>3600<br>3600|
|DC operated|5000<br>5000<br>5000<br>5000<br>5000<br>3600<br>3600<br>3600|
|Electrical life|See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**<br>See Curves,<br>**Page**<br>**V5-T1-111**|
|Electrical operating frequency (ops/hr)|600<br>600<br>600<br>600<br>600<br>600<br>600<br>600|
|Climatic proofing|1<br>1<br>1<br>1<br>1<br>1<br>1<br>1|
||2<br>2<br>2<br>2<br>2<br>2<br>2<br>2|
|Insulation voltage (Ui) Vac|690<br>690<br>690<br>690<br>690<br>690<br>690<br>690|
|Impulse withstand voltage (Uimp) Vac|8000<br>8000<br>8000<br>8000<br>8000<br>8000<br>8000<br>8000|
|Operation voltage (Ue) Vac|690<br>690<br>690<br>690<br>690<br>690<br>690<br>690|
|Safe isolation to VDE 0106 Part 101 and Part 101/A1<br>Between coil and contacts (Vac)|400<br>440<br>440<br>440<br>440<br>440<br>440<br>440|
|Between contacts (Vac)|400<br>440<br>440<br>440<br>440<br>440<br>440<br>440|
|Making capacity up to 690V (amps)|144<br>238<br>350<br>560<br>700<br>1120<br>1330<br>1800|
|Breaking capacity (amps)<br>220/230V|120<br>180<br>250<br>00<br>00<br>800<br>950<br>1150|
|380/400V|120<br>180<br>250<br>400<br>500<br>800<br>950<br>1150|
|500V|100<br>180<br>250<br>400<br>500<br>800<br>950<br>1150|
|660/690V|70<br>120<br>144<br>250<br>296<br>650<br>750<br>800|
|Short-circuit protection rating maximum fuse<br>Type 2 coordination<br>400V; gG/gL 500V|20<br>35<br>35<br>63<br>80<br>160<br>160<br>250|
|690V; gG/gL 690V|2<br>35<br>35<br>50<br>63<br>160<br>160<br>200|
|Type 1 coordination<br>400V; gG/gL 500V|35<br>6<br>100<br>125<br>160<br>250<br>250<br>250|
|690V; gG/gL 690V|25<br>50<br>50<br>80<br>80<br>200<br>200<br>200|
|Degree of protection with accessories|IP20<br>IP00<br>IP00<br>IP00<br>IP00<br>IP00<br>IP00<br>IP00|
||—<br>—<br>—<br>IP20<br>IP20<br>IP20<br>IP20<br>IP20|
|Protection against direct contact when<br>actuated from front (IEC 536)|Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof<br>Finger and<br>back-of-hand<br>proof|
## _**Notes**_
> 1 Damp heat, constant, to IEC 60068-2-3.
> 2 Damp heat, cyclical, to IEC 60068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-93**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## _**XT**_ **Contactors—Four-Pole, continued**
|**_XT_Contactors—Four-Pole, continued**|**_XT_Contactors—Four-Pole, continued**|**_XT_Contactors—Four-Pole, continued**|**_XT_Contactors—Four-Pole, continued**|||
|---|---|---|---|---|---|
|**Description**<br>**XTCF020B**<br>**XTCF032C**||||**XTCF045C**<br>**XTCF063D**<br>**XTCF080D**<br>**XTCF125G**<br>**XTCF160G**<br>**XTCF200G**||
|**General, continued**||||||
|Terminal capacity main cable—screw terminals<br>Solid (mm2)<br>1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–16)<br>2 x (0.75 –10)||||1 x (0.75–16)<br>2 x (0.75 –10)<br>1 x (2.5 –16)<br>2 x (2.5 –16)<br>1 x (2.5 –16)<br>2 x (2.5 –16)<br>—<br>—<br>—||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–16)<br>2 x (0.75–10)||||1 x (0.75–16)<br>2 x (0.75–10)<br>1 x (2.5–35)<br>2 x (2.5–25)<br>1 x (2.5–35)<br>2 x (2.5–25)<br>1 x (10 –95)<br>2 x (10–70)<br>1 x (10 –95)<br>2 x (10–70)<br>1 x (10 –95)<br>2 x (10–70)||
|Solid or stranded (AWG)<br>18–14<br>18–6||||18–6<br>12–2<br>12–2<br>8–250 kcmil<br>8–250 kcmil<br>8–250 kcmil||
|Terminal capacity control circuit cable—screw<br>terminals<br>Solid (mm2)<br>1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–4)<br>2 x (0.75–2.5)||||1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–4)<br>2 x (0.75–2.5)<br>1 x (0.75–4)<br>2 x (0.75–2.5)||
|Flexible with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||||1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)||
|Solid or stranded (AWG)<br>18–14||18–14||18–14|18–14<br>18–14<br>18–14<br>18–14<br>18–14|
|Main cable connection screw/bolt<br>Tightening torque<br>Nm<br>1.2||3||3|3.3<br>3.3<br>14<br>14<br>14|
|Lb-in<br>10.6||26.6||26.6|29.2<br>29.2<br>123.9<br>123.9<br>123.9|
|Control circuit cable connection screw/bolt<br>Tightening torque<br>Nm<br>1.2||1.2||1.2|1.2<br>1.2<br>1.2<br>1.2<br>1.2|
|Lb-in<br>10.6||10.6||10.6|10.6<br>10.6<br>10.6<br>10.6<br>10.6|
|Tools<br>Main and control circuit cable—<br>Screw terminals<br>2||2||2|2<br>2<br>—<br>—<br>—|
|Pozidriv screwdriver<br>0.8 x 5.5||0.8 x 5.5||0.8 x 5.5|0.8 x 5.5<br>0.8 x 5.5<br>—<br>—<br>—|
|Standard screwdriver<br>1|x 6|1 x 6||1 x 6|1 x 6<br>1 x 6<br>—<br>—<br>—|
|Mounting position, AC and DC operated<br>180°|90°|90°|||30°|
|||||90°|30|
|||||||
|||||||
|||||||
|Ambient temperature<br>Open<br>–25 to 60°C<br>(–13 to 140°F)<br>–25 to 60°C<br>(–13 to 140°F)||||–25 to 60°C<br>(–13 to 140°F)<br>–25 to 60°C<br>(–13 to 140°F)<br>–25 to 60°C<br>(–13 to 140°F)<br>–25 to 60°C<br>(–13 to 140°F)<br>–25 to 60°C<br>(–13 to 140°F)<br>–25 to 60°C<br>(–13 to 140°F)||
|Enclosed<br>–25 to 40°C<br>(–13 to 104°F)<br>–25 to 40°C<br>(–13 to 104°F)||||–25 to 40°C<br>(–13 to 104°F)<br>–25 to 40°C<br>(–13 to 104°F)<br>–25 to 40°C<br>(–13 to 104°F)<br>–25 to 40°C<br>(–13 to 104°F)<br>–25 to 40°C<br>(–13 to 104°F)<br>–25 to 40°C<br>(–13 to 104°F)||
|Ambient storage temperature<br>–40 to 80°C<br>(–40 to 176°F)<br>–40 to 80°C<br>(–40 to 176°F)||||–40 to 80°C<br>(–40 to 176°F)<br>–40 to 80°C<br>(–40 to 176°F)<br>–40 to 80°C<br>(–40 to 176°F)<br>–40 to 80°C<br>(–40 to 176°F)<br>–40 to 80°C<br>(–40 to 176°F)<br>–40 to 80°C<br>(–40 to 176°F)||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-94**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|**_XT_Contactors—Four-Pole, continued**<br>**Description**|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|---|---|---|---|---|---|---|---|---|
|**Environmental**|||||||||
|Mechanical shock resistance (IEC/EN 60068-2-27)|||||||||
|Half-sinusoidal shock 10 ms|||||||||
|Main contact—NO contact<br>Auxiliary contact—NO contact|10g<br>7g|10g<br>7g|10g<br>7g|10g<br>7g|10g<br>7g|10g<br>7g|10g<br>7g|10g<br>7g|
|Auxiliary contact—NC contact|5g|5g|5g|5g|5g|5g|5g|5g|
|Overvoltage category/pollution degree|III/3|III/3|III/3|III/3|III/3|III/3|III/3|III/3|
|**Coil Data Voltage Tolerance**|||||||||
|Pickup (x Uc)|||||||||
|AC operated|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|0.8–1.1|
|DC operated<br>Dropout (x Uc)|0.8–1.1|0.7–1.2|0.7–1.2|0.7–1.2|0.7–1.2|0.7–1.2|0.7–1.2|0.7–1.2|
|AC operated|0.4–0.6|0.4–0.6|0.4–0.6|0.4–0.6|0.4–0.6|0.4–0.6|0.4–0.6|0.4–0.6|
|DC operated|0.2–0.6|0.2–0.6|0.2–0.6|0.2–0.6|0.2–0.6|0.2–0.6|0.2–0.6|0.2–0.6|
|**Power Consumption of the Coil at Cold State**|**and 1.0 x Uc**||||||||
|AC operated 50/50Hz<br>Pickup VA|24|50|50|150|150|180|180|180|
|Pickup W<br>Sealing VA|19<br>4|40<br>8|40<br>8|95<br>16|95<br>16|150<br>3.1|150<br>3.1|150<br>3.1|
|Sealing W|1.2|2.4|2.4|4|4|2.1|2.1|2.1|
|DC operated|||||||||
|Pickup W|4.5|12|12|24|24|149|149|149|
|Sealing W<br>Duty factor (%DF)|4.5<br>100|0.5<br>100|0.5<br>100|0.5<br>100|0.5<br>100|2.1<br>100|2.1<br>100|2.1<br>100|
|**Switching Time at 100% Uc (Approximate Values)**|||||||||
|Main contact|||||||||
|AC operated|||||||||
|Closing delay (ms)|15 to 21|6 to 22|6 to 22|12 to 18|12 to 18|28 to 33|28 to 33|28 to 33|
|Opening delay (ms)|9 to 18|8 to 14|8 to 14|8 to 13|8 to 13|35 to 41|35 to 41|35 to 41|
|DC operated<br>Closing delay (ms)|31|47|47|54|54|35|35|35|
|Opening delay (ms)|12|30|30|24|24|30|30|30|
|Arcing time (ms)|10|10|10|10|10|15|15|15|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-95**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Auxiliary Contacts**
|**Auxiliary Contacts**||||||
|---|---|---|---|---|---|
||||||**XTCEXSBLN_**|
||||||**XTCEXSBN_**<br>**XTCEXSBNC_**|
||**XTCE007B_–**|**XTCEXFAC_**|**XTCEXFCC_**||**XTCEXSCN_**|
|**Description**|**XTCE032C**|**XTCEXFATC_**|**XTCEXSCC_**|**XTCEXFAG_**|**XTCEXSCNC_**|
|Interlocked opposing contacts with an auxiliary contact|—|Yes|Yes|Yes|Yes|
|module (to IEC 60947-5 -1 Annex L)||||||
|Break contact (not late-break contact) suitable as a mirror|XTCE007B_–|XTCE007B_–XTCE032C|XTCE007B_–XTCE032C|XTCE040D_–XTCE065D_|XTCE040D_–XTCE065D_|
|contact (to IEC/EN 60947-4 -1 Annex F)<br>Rated impulse withstand voltage, (Uimp) Vac|XTCE032C<br>6000|6000|6000|6000|XTCE185L_–XTCEC10N_<br>6000|
|Overvoltage category/pollution degree|III/3|III/3|III/3|III/3|III/3|
|Rated insulation voltage, (Ui) Vac|690|690|690|690|690|
|Rated operational voltage, (Ue) Vac|500|500|500|500|500|
|Safe isolation to VDE 0106 Part 101 and Part 101(A) in Vac<br>Between coil and auxiliary contacts|400|400|400|440|440|
|Between the auxiliary contacts|400|400|400|440|440|
|Rated operational current, le||||||
|AC-15||||||
|230V|6A|6A|6A|6A|6A|
|380/415V|4A|3A|4A|4A|4A|
|500V<br>DC-3 L/R <<br>~~5~~ms1|1.5A|—|1.5A|1.5A|1.5A|
|24V|10A|10A|10A|10A|10A|
|60V|6A|6A|6A|6A|6A|
|110V|3A|3A|3A|3A|3A|
|220V|1A|1A|1A|1A|1A|
|Conventional thermal current, Ith|16A|16A|16A3|10A|10A|
|Control circuit reliability<br>(at Ue= 24 Vdc, Umin = 17 V, Imin= 5.4 mA)|<10-8, <1 failure at<br>100 million operations|<10-8, <1 failure at<br>100 million operations|<10-8, <1 failure at<br>100 million operations|<10-8, <1 failure at<br>100 million operations|<10-8, <1 failure at<br>100 million operations|
|Component lifespan, operations x 106<br>at Ue= 230V, AC-15, 3A|1.3|1.3|1.3|1.3|1.3|
|Short-circuit rating without welding2<br>Maximum fuse, gG/gL|10A|10A|10A|16A|16A|
## _**Notes**_
> 1 Making and breaking conditions to DC-13, time L/R contact as stated.
> 2 See fuses overlay for time/current characteristic (on request).
> 3 Conventional thermal current (Ith) of XTCEXSCC_ is 10A.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-96**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Parallel Link**
|**Parallel Link**||||||
|---|---|---|---|---|---|
|**Description**|**XTCEXPLKB**|**XTECXPLKC**|**XTCEXPLKD**|**XTCEXPLKG**|**XTCEXPLK185**|
|Terminal capacity||||||
|Solid (mm2)|1–16|16|16|—|—|
|Flexible with ferrule (mm2)|1 x (0.5–25)|1 x (16–35)|1 x (16–120)|—|—|
||2 x (0.5–16)|||||
|Stranded (mm2)|1 x (0.5–25)|1 x (16–50)|1 x (16–120)|1 x (35–300)|—|
||2 x (0.5–16)|||2 x (35–120)||
|Flat conductor—number of segments x width x thickness (mm)|6 x 9 x 0.8|—|—|2 x (11 x 21 x 1)|1 x (6 x 16 x 0.8)|
||||||2 x (20 x 32 x 0.5)|
|Tightening torque (Nm)|4|4|14|—|2 x (11 x 21 x 1)<br>—|
|Tools||||||
|Pozidriv screwdriver|Size 2|Size 2|—|—|—|
|Hexagon socket head spanner—SW (mm)|—|—|5|6|—|
|Conventional thermal current||||||
|Three-pole (Ith) A|50|100|180|400|—|
|Four-pole (Ith) A|60|—|—|—|—|
|**Cable Terminal Block, Flat Cable Terminal**||||||
|---|---|---|---|---|---|
|**Description**|**XTCEXTLA225A**|**XTCEXTLA400**|**XTCEXPLK185**|**XTCEXTFB650**|**XTCEXTFB820**|
|Terminal capacity||||||
|Stranded (mm2)|1 x (16–185)|1 x (120–300)|—|—|—|
||2 x (16–150)|2 x (70–240)||||
|Stranded (AWG)|1 x (6–350 kcmil)|1 x (250–600 kcmil)|—|—|—|
||2 x (6–350 kcmil)|2 x (2/0–500 kcmil)||||
|Flat conductor—number of segments x width x thickness (mm)|—|—|1 x (6 x 16 x 0.8)<br>2 x (20 x 32 x 0.5)|1 x (6 x 16 x 0.8)<br>2 x (20 x 32 x 0.5)|1 x (6 x 16 x 0.8)<br>2 x (10 x 40 x 1)|
||||2 x (11 x 21 x 1)|2 x (11 x 21 x 1)|2 x (20 x 40 x 0.5)|
|**AC Ratings—AC-1 Operation**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**XTCE007B**|**XTCE009B**|**XTCE012B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|
|Conventional free air thermal current, three-pole, 50–60 Hz||||||||
|Open||||||||
|at 40°C (Ith)|22A|22A|22A|22A|40A|45A|45A|
|at 50°C (Ith)|21A|21A|21A|21A|38A|43A|43A|
|at 55°C (Ith)<br>at 60°C (Ith)|21A<br>20A|21A<br>20A|21A<br>20A|21A<br>20A|37A<br>35A|42A<br>40A|42A<br>40A|
|Enclosed|18A|18A|18A|18A|32A|36A|36A|
|Conventional free air thermal current, single-pole (Ith)||||||||
|Open|50A|50A|50A|50A|88A|100A|100A|
|Enclosed|45A|45A|45A|45A|80A|90A|90A|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-97**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## **AC Ratings—AC-3 Operation**
|**AC Ratings—AC-3 Operation**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**XTCE007B**|**XTCE009B**|**XTCE012B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|
|Rated operational current, 50/60 Hz1(Ie) in amperes||||||||
|220/230V|7|9|12|15.5|18|25|32|
|240V|7|9|12|15.5|18|25|32|
|380/400V<br>415V|7<br>7|9<br>9|12<br>12|15.5<br>15.5|18<br>18|25<br>25|32<br>32|
|440V|7|9|12|15.5|18|25|32|
|500V|5|7|10|12.5|18|25|32|
|660/690V|4|5|7|9|12|15|18|
|1000V|—|—|—|—|—|—|—|
|Rated power (P) in kilowatts||||||||
|220/230V<br>240V|2.2<br>2.2|2.5<br>3|3.5<br>4|4<br>4.6|5<br>5.5|7.5<br>8.5|10<br>11|
|380/400V|3|4|5.5|7.5|7.5|11|15|
|415V|4|5.5|7|8|10|14.5|19|
|440V|4.5|5.5|7.5|8.4|10.5|15.5|20|
|500V|3.5|4.5|7|7.5|12|17.5|23|
|660/690V|3.5|4.5|6.5|7|11|14|17|
|1000V|—|—|—|—|—|—|—|
## **AC Ratings—AC-4 Operation**
|**AC Ratings—AC-4 Operation**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**XTCE007B**|**XTCE009B**|**XTCE012B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|
|Rated operational current, 50/60 Hz2(Ie) in amperes||||||||
|220/230V|5|6|7|7|10|13|15|
|240V|5|6|7|7|10|13|15|
|380/400V|5|6|7|7|10|13|15|
|415V|5|6|7|7|10|13|15|
|440V|5|6|7|7|10|13|15|
|500V|4.5|5|6|6|1|13|1|
|660/690V|4|4.5|5|5|8|10|12|
|1000V|—|—|—|—|—|—|—|
|Rated power (P) in kilowatts<br>220/230V|1|1.5|2|2|2.5|3.5|4|
|240V|1.5|1.6|2.2|2.2|3|4|4.5|
|380/400V|2.2|2.5|3|3|4.5|6|7|
|415V|2.3|2.8|3.4|3.4|5|6.5|7.5|
|440V|2.4|3|3.6|3.6|5.5|7|8|
|500V|2.5|2.8|3.5|3.5|6|8|9|
|660/690V<br>1000V|2.9<br>—|3.6<br>—|4.4<br>—|4.4<br>—|6.5<br>—|8.5<br>—|10<br>—|
## _**Notes**_
> 1 At maximum permissible ambient temperature.
> 2 Example—
The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-98**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|**AC Ratings—AC-6A Operation**<br>**Description**<br>**XTCE007B**|**XTCE009B**|**XTCE012B**||**XTCE015B**||**XTCE018C**|**XTCE025C**|**XTCE032C**|
|---|---|---|---|---|---|---|---|---|
|Transformer loads<br>Values are<br>application specific|Values are<br>application specific|Values are<br>application|specific|Values are<br>application specific||Values are<br>application specific|Values are<br>application specific|Values are<br>application specific|
|Calculation is IeAC-3 = X / 6||* Ietransformer|where X is the inrush current of the transformer and Ietransformer is the nominal|||||current.1|
|**AC Ratings—AC-6B Operation**|||||||||
|**Description**|**XTCE007B**|**XTCE009B**|**XTCE012B**||**XTCE015B**<br>**XTCE018C**||**XTCE025C**|**XTCE032C**|
|Capacitor loads|||||||||
|Individual compensation rated operational current Ie<br>of three-phase capacitors in amperes|||||||||
|Up to 525V||||See**Page V5-T1-63**for capacitor ratings|||||
|690V||||See**Page V5-T1-63**for capacitor ratings|||||
|Maximum inrush current peak (x Ie)|30|30|30||30|30|30|30|
|Component lifesaving (operations)<br>Maximum operating frequency (ops/hr)|—<br>—|—<br>—|—<br>—||—<br>—|—<br>—|—<br>—|—<br>—|
## **AC Ratings—AC-1 Operation**
|**AC Ratings—AC-1 Operation**||||||||||
|---|---|---|---|---|---|---|---|---|---|
|**Description**|**XTCE040D**|**XTCE050D**|**XTCE065D**|**XTCE072D**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|Conventional free air thermal current,<br>three-pole, 50–60 Hz||||||||||
|Open||||||||||
|at 40°C (Ith)|60A|80A|98A|98A|110A|130A|160A|190A|275A2|
|at 50°C (Ith)|57A|71A|88A|88A|98A|125A|142A|180A|200A|
|at 55°C (Ith)<br>at 60°C (Ith)|55A<br>50A|68A<br>65A|83A<br>80A|83A<br>80A|94A<br>90A|115A<br>110A|135A<br>130A|170A<br>160A|190A<br>185A|
|Enclosed|45A|58A|72A|72A|80A|100A|115A|144A|166A|
|Conventional free air thermal current,||||||||||
|single-pole (Ith)<br>Open|125A|162A|200A|200A|225A|275A|325A|400A|460A|
|Enclosed|112A|145A|180A|180A|200A|250A|285A|360A|415A|
## _**Notes**_
> 1 Example—
The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
- 2 For 225–275A, use 2X 70 mm2 wire.
- 3 At maximum permissible ambient temperature.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-99**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **AC Ratings—AC-3 Operation**
|**1**|**AC Ratings—AC-3 Operation**<br>**Description**|**XTCE040D**|**XTCE050D**|**XTCE065D**|**XTCE072D**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|---|---|---|---|---|---|---|---|---|---|---|
|**1**|Rated operational current, 50/60 Hz1(Ie) in amperes||||||||||
||220/230V|40|50|65|72|80|95|115|150|170|
|**1**|240V|40|50|65|72|80|95|115|150|170|
|**1**|380/400V<br>415V|40<br>40|50<br>50|65<br>65|7<br>72|80<br>80|95<br>95|115<br>115|150<br>150|170<br>170|
|**1**|440V|40|50|65|72|80|95|115|15|170|
||500V|40|50|65|72|80|95|115|150|170|
|**1**|660/690|25|32|37|37|65|80|93|100|150|
||1000V|—|—|—|—|—|—|—|—|—|
|**1**|Rated power (P) in kilowatts||||||||||
|**1**|220/230V<br>240V|12.5<br>13.5|15.5<br>17|20<br>22|22<br>35|25<br>27.5|30<br>34|37<br>40|48<br>52|52<br>57|
|**1**|380/400V|18.5|22|30|37|37|45|55|75|90|
||415V|24|30|39|41|43|57|70|91|100|
|**1**|440V|25|32|41|44|51|60|75|95|105|
||500V|28|36|47|45|58|70|85|110|120|
|**1**|660/690V|23|30|35|35|63|75|90|96|140|
|**1**|1000V|—|—|—|—|—|—|—|—|—|
|**1**|**AC Ratings—AC-4 Operation**||||||||||
|**1**|**Description**|**XTCE040D**|**XTCE050D**|**XTCE065D**|**XTCE072D**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
||Rated operational current, 50/60 Hz1(Ie) in amperes||||||||||
|**1**|220/230V|18|21|25|25|40|50|55|65|65|
||240V|18|21|25|25|40|50|55|65|65|
|**1**|380/400V|18|21|25|25|40|50|55|65|65|
|**1**|415V|18|21|25|25|40|50|55|65|65|
||440V|18|21|25|25|40|50|55|65|65|
|**1**|500V|18|21|25|25|40|50|55|65|65|
||660/690V|14|17|20|20|40|50|45|50|50|
|**1**|1000V|—|—|—|—|—|—|—|—|—|
|**1**|Rated power (P) in kilowatts<br>220/230V|5|6|7|7|12|16|17|20|20|
|**1**|240V|5.5|6.5|7.5|7.5|13|17|19|22|22|
||380/400V|9|10|12|12|20|26|28|33|33|
|**1**|415V|9.5|11|13|13|24|30|33|39|39|
||440V|10|12|14|14|25|32|35|41|41|
|**1**|500V|11|13|16|16|29|36|40|47|47|
|**1**|660/690V<br>1000V|12<br>—|14<br>—|17<br>—|17<br>—|26<br>—|35<br>—|43<br>—|48<br>—|48<br>—|
## _**Note**_
> 1 At maximum permissible ambient temperature.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-100**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **AC Ratings—AC6-A Operation**
|**Description**|**XTCE040D**|**XTCE050D**|**XTCE065D**|**XTCE072D**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|---|---|---|---|---|---|---|---|---|---|
|Transformer loads|Values are<br>application|Values are<br>application|Values are<br>application|Values are<br>application|Values are<br>application|Values are<br>application|Values are<br>application|Values are<br>application|<br>Values are<br>application|
||specific|specific<br>specific<br>specific<br>specific<br>specific<br>Calculation is IeAC-3 = X / 6 * Ietransformer where X is the inrush current of the transformer|||||specific<br>specific<br>and Ietransformer is the nominal||specific<br>current.1|
## **AC Ratings—AC6-B Operation**
|**AC Ratings—AC6-B Operation**||||||||||
|---|---|---|---|---|---|---|---|---|---|
|**Description**|**XTCE040D**|**XTCE050D**|**XTCE065D**|**XTCE072D**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|Capacitor loads<br>Individual compensation rated operational current Ieof||||||||||
|three-phase capacitors in amperes<br>Up to 525V||||See**Page**|**V5-T1-63**for capacitor ratings|||||
|690V||||See**Page**|**V5-T1-63**for capacitor ratings|||||
|Maximum inrush current peak (x Ie)|30|30|30|30|30|30|30|30|30|
|Component lifesaving (operations)|—|—|—|—|—|—|—|—|—|
|Maximum operating frequency (ops/hr)|—|—|—|—|—|—|—|—|—|
## **AC Ratings—AC-1 Operation**
|**AC Ratings—AC-1 Operation**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Description**<br>Conventional free air thermal current, three-pole, 50–60 Hz|**XTCE185H**|**XTCE225L**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|**XTCE570M**|**XTCE580N**|
|at 40°C (Ith)|337|356|429|490|612|857|857|980|
|at 50°C (Ith)|301|310|383|438|548|767|767|876|
|at 55°C (Ith)|287|295|366|418|522|731|731|836|
|at 60°C (Ith)|275|285|350|400|500|700|700|800|
|Conventional free air thermal current, single-pole (Ith)|245|275|875|315|1250|1750|1750|2000|
## _**Note**_
> 1 Example—The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-101**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **AC Ratings—AC-3 Operation**
|**AC Ratings—AC-3 Operation**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Description**|**XTCE185H**|**XTCE225L**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|**XTCE570M**|**XTCE580N**|
|Rated operational current, 50/60 Hz1(Ie) in amperes|||||||||
|220/230V<br>185<br>225|||250<br>300||400|500|580|580|
|240V<br>185<br>225|||250<br>300||400|500|580|580|
|380/400V<br>185<br>225|||250<br>300||400|500|580|580|
|415V<br>185<br>225|||250<br>300||400|500|580|580|
|440V<br>185<br>225<br>500V<br>185<br>225|||250<br>300<br>250<br>300||400<br>400|500<br>500|580<br>580|580<br>580|
|660/690V<br>150<br>160|||250<br>210||400|500|580|580|
|1000V<br>76<br>76|||76<br>95||95|95|95|435|
|Rated power (P) in kilowatts|||||||||
|220/230V<br>55<br>70|||75<br>90||125|155|185|185|
|240V<br>62<br>75|||85<br>100||132|170|200|200|
|380/400V<br>90<br>110<br>415V<br>110<br>132|||132<br>160<br>148<br>180||200<br>240|250<br>300|315<br>348|315<br>348|
|440V<br>115<br>138|||157<br>185||255|345|370|370|
|500V<br>132<br>160|||180<br>215||290|360|420|420|
|660/690V<br>140<br>150|||240<br>195||344|344|344|560|
|1000V<br>108<br>108|||108<br>132||132|132|132|600|
|**AC Ratings—AC-4 Operation**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Description**<br>Rated operational current, 50/60 Hz1(Ie) in amperes|**XTCE185H**|**XTCE225L**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|**XTCE570M**|**XTCE580N**|
|220/230V<br>136<br>164|||200<br>200||296|360|360|456|
|240V<br>136<br>164|||200<br>200||296|360|360|456|
|380/400V<br>136<br>164|||200<br>200||296|360|360|456|
|415V<br>136<br>164|||200<br>200||296|360|360|456|
|440V<br>136<br>164|||200<br>200||296|360|360|456|
|500V<br>136<br>164<br>660/690V<br>110<br>120|||200<br>200<br>200<br>200||296<br>296|360<br>360|360<br>360|456<br>456|
|1000V<br>55<br>55|||76<br>76||95|95|95|348|
|Rated power (P) in kilowatts|||||||||
|220/230V<br>41<br>51|||62<br>75||92|112|112|143|
|240V<br>45<br>54|||68<br>82||101|122|122|156|
|380/400V<br>75<br>90|||110<br>132||160|200|200|250|
|415V<br>80<br>96|||117<br>142||176|216|216|274|
|440V<br>85<br>102|||125<br>150||186|229|229|290|
|500V<br>96<br>116|||143<br>172||214|260|260|330|
|660/690V<br>102<br>110|||189<br>160||283|344|344|440|
|1000V<br>77<br>77|||108<br>109||132|132|132|509|
## _**Note**_
> 1 At maximum permissible ambient temperature.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-102**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|**AC Ratings—AC-1 Operation**<br>**Description**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC16R**|**XTCEC20R**|
|---|---|---|---|---|---|---|---|
|Conventional free air thermal current, three-pole,<br>50–60 Hz||||||||
|at 40°C (Ith)<br>at 50°C (Ith)|1041<br>931|1102<br>986|1225<br>1095|1225<br>1095|17141<br>15331|2200<br>1970|24501<br>21901|
|at 55°C (Ith)|888|940|1044|1044|14621|1800|20891|
|at 60°C (Ith)|850|900|1000|1000|14001|1800|20001|
|Conventional free air thermal current,|2125|2250|2500|2500|3500|4500|5000|
|single-pole (Ith)||||||||
## **AC Ratings—AC-3 Operation**
|**AC Ratings—AC-3 Operation**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC16R**|**XTCEC20R**|
|Rated operational current, 50/60 Hz2(Ie) in amperes||||||||
|220/230V<br>240V|650<br>650|750<br>750|820<br>820|1000<br>1000|—<br>—|1600<br>1600|—<br>—|
|380/400V|650|750|820|1000|—|1600|—|
|415V|650|750|820|1000|—|1600|—|
|440V|650|750|820|1000|—|1600|—|
|500V<br>660/690V|650<br>650|750<br>750|820<br>820|1000<br>1000|—<br>—|1600<br>1600|—<br>—|
|1000V|435|580|580|700|—|—|—|
|Rated power (P) in kilowatts||||||||
|220/230V|205|240|260|315|—|500|—|
|240V|225|260|285|340|—|550|—|
|380/400V|355|400|450|560|—|900|—|
|415V<br>440V|390<br>420|455<br>480|500<br>525|610<br>650|—<br>—|930<br>1000|—<br>—|
|500V|470|550|600|730|—|1180|—|
|660/690V|630|720|750|1000|—|1600|—|
|1000V|600|800|800|1000|—|—|—|
## _**Notes**_
> 1 Up to 690V.
- 2 At maximum permissible ambient temperature.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-103**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **AC Ratings—AC-4 Operation**
|**1**|**AC Ratings—AC-4 Operation**<br>**Description**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC16R**|**XTCEC20R**|
|---|---|---|---|---|---|---|---|---|
|**1**|Rated operational current, 50/60 Hz1(Ie) in amperes||||||||
||220/230V|512|576|656|800|—|1280|—|
|**1**|240V|512|576|656|800|—|1280|—|
|**1**|380/400V<br>415V|512<br>512|576<br>576|656<br>656|800<br>800|—<br>—|1280<br>1280|—<br>—|
|**1**|440V|512|576|656|800|—|1280|—|
||500V|512|576|656|800|—|1280|—|
|**1**|660/690V|512|576|656|800|—|1280|—|
||1000V|348|464|464|700|—|—|—|
|**1**|Rated power (P) in kilowatts||||||||
|**1**|220/230V<br>240V|161<br>176|181<br>200|209<br>228|260<br>280|—<br>—|30<br>450|—<br>—|
|**1**|380/400V|280|315|355|450|—|750|—|
||415V|307|346|394|490|—|770|—|
|**1**|440V|32|367|41|520|—|830|—|
||500V|370|417|474|590|—|940|—|
|**1**|660/690V|494|556|633|780|—|1300|—|
|**1**|1000V|509|678|678|1000|—|—|—|
|**AC Ratings—AC-6A**|**Operation**|||||||
|---|---|---|---|---|---|---|---|
|**Description**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC16R**|**XTCEC20R**|
|Transformer loads|Values are|Values are|Values are|Values are|Values are|Values are|Values are|
||application<br>specific|application<br>specific|application<br>specific|application<br>specific|application<br>specific|application<br>specific|application<br>specific|
Calculation is Ie AC-3 = X / 6 * Ie transformer where X is the inrush current of the transformer and Ie transformer is the nominal current.[2]
## _**Notes**_
> 1 At maximum permissible ambient temperature.
> 2 Example—The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-104**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **AC Ratings—AC-6B Operation**
|**AC Ratings—AC-6B Operation**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC16R**|**XTCEC20R**|
|Capacitor loads<br>Individual compensation rated operational||||||||
|current Ieof three-phase capacitors in amperes<br>Up to 525V|463|463|463|463|—|—|—|
|690V|265|265|265|265|—|—|—|
|Maximum inrush current peak (x Ie)|30|30|30|30|—|—|—|
|Component lifesaving (operations)|100,000|100,000|100,000|100,000|—|—|—|
|Maximum operating frequency (ops/hr)|200|200|200|200|—|—|—|
## **AC Ratings—Four-Pole—AC-1 Operation**
|**Description**<br>Conventional free air thermal current, three-pole, 50-60 Hz|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|---|---|---|---|---|---|---|---|---|
|Open (amps)|||||||||
|at 40°C (Ith)|22|32|45|3|80|125|160|200|
|at 50°C (Ith)|21|30|41|60|76|116|15|188|
|at 60°C (Ith)|20|28|39|54|69|108|138|172|
|Enclosed (amps)|18|27|36|50|64|100|128|160|
|Conventional free air thermal current, single-pole<br>Open (amps)|60|84|117|162|207|325|415|516|
|Enclosed (amps)|54|76|105|146|186|292|373|464|
## **AC Ratings—Four-Pole—AC-3 Operation**
|**Description**|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|---|---|---|---|---|---|---|---|---|
|Rated operational current, 50/60 Hz (Ie) in amperes<br>220/230V|12|18|25|40|50|80|95|115|
|240V|12|18|25|40|50|80|95|115|
|380/400V|12|18|25|40|50|80|95|115|
|415V|12|18|25|40|50|80|95|115|
|440V|12|18|25|40|50|80|95|115|
|500V|10|18|25|40|50|80|95|115|
|660/690V<br>Rated power, (P) in kilowatts|7|12|15|25|32|65|80|93|
|220/230V|3.5|5|7.5|2.5|15.5|25|30|37|
|240V|4|5.5|8.5|13.5|17|27.5|33|40|
|380/400V|5.5|7.5|11|18.5|22|37|45|55|
|415V|7|10|14.5|24|30|48|57|70|
|440V|7.5|10.5|15.5|25|32|51|60|75|
|500V<br>660/690V|47<br>6.5|12<br>11|17.5<br>14|28<br>23|36<br>30|58<br>63|70<br>75|85<br>90|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-105**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **DC Ratings—DC-1**
|**1**|**DC Ratings—**<br>**Description**|**DC-1**||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|**1**|**Rated Operation**<br>**Current {1} (Ie) in**|||**XTCE012B,**||||||||
||**Amperes**|**XTCE007B**|**XTCE009B**|**XTCF020B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|**XTCE040D**|**XTCE050D**|**XTCE065D**|
|**1**|60V|20|20|20|20|35|40|40|50|60|72|
||110V|20|20|20|20|35|40|40|50|50|72|
|**1**|220V|15|15|15|15|3|4|40|45|45|65|
|**1**|440V|1|1.3|1.3|1.3|2.9|2.9|2.9|2.9|2.9|2.9|
|**1**||**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE185H**|**XTCE225H**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|
||60V|110|110|160|160|300|300|300|300|400|400|
|**1**|110V|110|110|16|160|300|300|300|300|400|400|
|**1**|220V<br>440V|70<br>4.5|70<br>4.5|90<br>4.5|90<br>4.5|300<br>11|300<br>11|300<br>11|300<br>11|400<br>11|400<br>11|
|**1**||||||||||||
|||**XTCE580N**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC20R**|**XTCEC16R**|||
|**1**|60V|—|—|—|—|—|—|—|—|||
|**1**|110V<br>220V|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|||
|**1**|440V|—|—|—|—|—|—|—|—|||
## **DC Ratings—DC-3**
|**Description**<br>**Rated Operation**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Current {1} (Ie) in**<br>**Amperes**|**XTCE007B**|**XTCE009B**|**XTCE012B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|**XTCE040D**|**XTCE050D**|**XTCE065D**|
|60V|20|20|20|20|35|35|40|50|60|72|
|110V|20|20|20|20|35|35|40|50|50|72|
|220V|1.5|1.5|1.5|1.5|10|10|25|25|25|35|
|440V|0.2|0.2|0.2|0.2|0.6|0.6|0.6|0.6|0.6|0.6|
||**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE185H**|**XTCE225H**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|
|60V|110|110|160|160|300|300|300|300|400|400|
|110V<br>220V|110<br>35|110<br>35|160<br>40|160<br>40|300<br>300|300<br>300|300<br>300|300<br>300|400<br>400|400<br>400|
|440V|1|1|1|1|—|—|—|—|—|—|
||**XTCE580N**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC20R**|**XTCEC16R**|||
|60V<br>110V|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|||
|220V|—|—|—|—|—|—|—|—|||
|440V|—|—|—|—|—|—|—|—|||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-106**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **DC Ratings—DC-5**
|**Description**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Rated Operation**<br>**Current {1} (Ie) in**|||||||||||
|**Amperes**|**XTCE007B**|**XTCE009B**|**XTCE012B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|**XTCE040D**|**XTCE050D**|**XTCE065D**|
|60V|20|20|20|20|35|35|40|50|60|72|
|110V|20|20|20|20|35|35|40|50|50|72|
|220V|1.5|1.5|1.5|1.5|10|10|25|25|25|35|
|440V|0.2|0.2|0.2|0.2|0.6|0.6|0.6|0.6|0.6|0.6|
||**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE185H**|**XTCE225H**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|
|60V|110|110|160|160|300|300|300|300|400|400|
|110V|110|110|160|160|300|300|300|300|400|400|
|220V<br>440V|35<br>1|35<br>1|40<br>1|40<br>1|300<br>—|300<br>—|300<br>—|300<br>—|400<br>—|400<br>—|
||**XTCE580N**|**XTCE650N**|**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC20R**||||
|60V|—|—|—|—|—|—|—||||
|110V<br>220V|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—||||
|440V|—|—|—|—|—|—|—||||
## **DC Ratings—Four-Pole—DC-1 Operation**
|**Description**<br>**Rated Operation**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Current {1} (Ie) in**<br>**Amperes**|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|60V|22|32|45|63|80|125|160|200|
|110V|22|32|45|6|80|125|160|200|
|220V|6|32|45|63|80|125|160|200|
|440V|1.3|3|3|5|5|100|125|150|
## **DC Ratings—Four-Pole—DC-3 Operation**
|**Description**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Rated Operation**<br>**Current {1} (Ie) in**|||||||||
|**Amperes**|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|60V|20|32|45|63|80|125|160|200|
|110V|20|32|45|63|80|125|160|200|
|220V|1.5|32|45|63|80|125|160|200|
|440V|0.2|6|6|8|8|75|95|115|
## **DC Ratings—Four-Pole—DC-5 Operation**
|**Description**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Rated Operation**|||||||||
|**Current {1} (Ie) in**<br>**Amperes**|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|60V<br>110V|20<br>20|32<br>25|45<br>32|63<br>508|80<br>80|125<br>125|160<br>160|200<br>200|
|220V|1.5|15|22|38|70|100|125|150|
|440V|0.2|4|4|8|8|60|75|90|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-107**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Current Heat Loss (Three-Pole) in Watts**
||||**XTCE012B,**||||||
|---|---|---|---|---|---|---|---|---|
|**Description**<br>Current heat loss (three-pole) in watts|**XTCE007B**|**XTCE009B**|**XTCF020B**|**XTCE015B**|**XTCE018C**|**XTCE025C**|**XTCE032C**|**XTCE040D**|
|at Ith|3|3|3|3|7.3|9.6|12.1|11.3|
|at Ieto AC-3/400V|0.37|0.6|1.1|1.8|1.9|3.8|6.1|7.2|
|Impedance per pole, megohms|2.5|2.5|2.5|2.5|2|2|2|1.5|
||**XTCE050D**|**XTCE065D**|**XTCE072D**|**XTCE080F**|**XTCE095F**|**XTCE115G**|**XTCE150G**|**XTCE170G**|
|Current heat loss (three-pole) in watts|||||||||
|at Ith|19|28.8|28.8|12.2|18.2|20.3|30.7|41.1|
|at Ieto AC-3/400V|11.3|19|23|9.6|13.5|15.9|27.0|34.7|
|Impedance per pole, megohms|1.5|1.5|1.5|0.5|0.5|0.4|0.4|0.4|
|Current heat loss (three-pole) in watts|**XTCE185H**|**XTCE225H**|**XTCE250L**|**XTCE300L**|**XTCE400M**|**XTCE500M**|**XTCE580N**|**XTCE650N**|
|at Ith|34|45|55|37|58|113|61|69|
|at Ieto AC-3/400V|16|23|28|21|37|58|32|41|
|Impedance per pole, megohms|—|—|—|—|—|—|—|—|
||**XTCE750N**|**XTCE820N**|**XTCEC10N**|**XTCEC14P**|**XTCEC20R**|**XTCEC16R**|||
|Current heat loss (three-pole) in watts|||||||||
|at Ith|78|96|96|188|192|155|||
|at Ieto AC-3/400V|54|65|96|—|—|123|||
|Impedance per pole, megohms|—|—|—|—|—|—|||
|**Current Heat Loss (Four-Pole) in Watts**|||||||||
|**Description**<br>Current heat loss (four-pole) in watts|**XTCF020B**|**XTCF032C**|**XTCF045C**|**XTCF063D**|**XTCF080D**|**XTCF125G**|**XTCF160G**|**XTCF200G**|
|at Ith|4.7|8.2|12|16|23|29|46|60|
|Impedance per pole, megohms|2.5|2|1.5|1|0.7|0.6|0.6|0.5|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-108**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Wiring Diagrams**
## _**7–150A XTCR Reversing Contactors**_
## **Control Circuit—7–32A Control Circuit—40–170A**
**==> picture [204 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
21 21<br>0 22 0 22<br>II 21 22 II 21 22<br>22 21 22 21<br>14 13 14 13<br>K1MI 13 5453 K2M 5354 14 K1MI 13 1413 K2M 13 [14] 14<br>22 22<br>K2M 21 K1M 21 K2M [22] K1M [22]<br>A1 A1 21 21<br>K1M A1 A1<br>A2 [K2M] A2 K1M K2M<br>(-)N A2 A2<br>**----- End of picture text -----**<br>
## _**Star-Delta (Wye-Delta) Starters**_
## **Power Circuit—12–385A AC-3**
**==> picture [119 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1L2 L3<br>F1<br>B 1 x ln<br>1 3 5 1 3 5 1 3 5<br>K1M 2 4 6 K5M 2 4 6 K3M 2 4 6<br>0.58 x ln A C<br>0.58 x ln<br>U1 V2<br>V1 M1 W2<br>W1 3~ U2<br>M1<br>**----- End of picture text -----**<br>
## **Control Circuit—12–55A AC-3**
**==> picture [137 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
21<br>0 22<br>S11<br>K1M<br>13 13<br>I 14 14<br>54 54 54 17 17<br>K1M 53 53 53 K1 18 K1 28<br>K3M K5M<br>22 22<br>K5M 21 K3M 21<br>A1 A1 A1 A1<br>K1M K1T K3M K5M<br>A2 A2 A2 A2<br>(–)N<br>N Y<br>**----- End of picture text -----**<br>
## **Control Circuit—70–1700A AC-3**
**==> picture [134 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
21<br>0 22<br>S11<br>K1M<br>13 13<br>I 14 14<br>44 14 14 17 17<br>K1M 43 13 13 K1 18 K1 28<br>K3M K5M<br>22 22<br>K5M 21 K3M 21<br>A1 A1 A1 A1<br>K1M K1T K3M K5M<br>A2 A2 A2 A2<br>(–)N<br>N Y<br>**----- End of picture text -----**<br>
**Power Circuit—7–150A with Mechanical Interlock 80– 150A on Mounting Plate**
**==> picture [75 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 3 5 1 3 5<br>K1M<br>2 4 6 K2M 2 4 6<br>U V W<br>M1 M<br>3<br>**----- End of picture text -----**<br>
## _**XTCC Contactors for Three-Phase Capacitors**_
## **Power Circuit—11–85 kVAR**
**==> picture [72 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2 L3<br>A1 1 3 5<br>A2 2 4 6<br>R11 R11<br>C1<br>R11<br>**----- End of picture text -----**<br>
In the case of group compensation, multi-stage capacitor banks are connected to the mains, as required. In the process, transient currents of up to 180 x Ie can flow between the capacitors. The capacitors are pre-charged via the earlymake auxiliary contacts and the fitted wire resistors, thereby reducing the inrush current. The main contacts then close after a time lag and carry the uninterrupted current. The contactors for capacitors are weld-resistant with inrush current peaks up to 180 x 1 Ie due to their special contacts. For switching reactive-power compensation equipment with chokes, observe design notes.
For switching of power factor connection with reactors, please observe engineering notes, **Page V5-T1-64** . Use of the contactors XTCE without series resistor for centralized power factor correction— when using contactors for group compensation, a minimum inductance of approximately 6 μH per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with 5 windings and a coil diameter of approximately 140 mm diameter. The conductor cross-section must be selected according to the rated current per phase.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-109**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Contactor Contact Travel Diagrams**
**==> picture [491 x 553] intentionally omitted <==**
**----- Start of picture text -----**<br>
Frame B<br>XTCE 7–15A, XTC—AC XTCE 7–9A—DC XTCE 12–15A, XTCF—DC<br>NO contact NO contact NO contact<br>0 3.3 4.5 0 2.1 2.9 0 3.3 4.4<br>NC contact NC contact NC contact<br>0 1.0 4.5 0 0.7 2.9 0 1.0 4.4<br>XTCEXSAC11 XTCEXSAC11 XTCEXSAC11<br>NO contact NO contact NO contact<br>0 3.2 4.5 0 2.3 2.9 0 3.2 4.4<br>NC contact NC contact NC contact<br>0 1.6 4.5 0 0.7 2.9 0 1.6 4.4<br>XTCEXF...LC_ XTCEXF...LC_ XTCEXF...LC_<br>NO contact NO contact NO contact<br>0 2.0 4.5 0 1.1 2.9 0 2.0 4.4<br>NC contact NC contact NC contact<br>0 2.8 4.5 0 1.9 2.9 0 2.8 4.4<br>Frame C Frame D Frames F and G<br>XTCE 15–32A XTCE 40–72A XTCE 80–170A<br>NO contact NO contact NO contact<br>0 4 6.0 0 5.1 7.5 0 8 11<br>Auxiliary NC<br>1.8<br>Auxiliary NO XTCEXF...G_ XTCEXF...G_<br>3.2<br>NO contact NO contact<br>0 5.7 7.5 0 9.2 11<br>NC contact NC contact<br>XTCEXSAC11, XTCEXF...C_ 0 3.9 7.5 0 7.4 11<br>NO contact<br>0 3.2 6<br>NC contact XTCEXF...LG_ XTCEXF...LG_<br>0 1.6 6<br>NO contact NO contact<br>0 3.8 7.5 0 7.3 11<br>NC contact NC contact<br>XTCEXF...LC_ 0 5.4 7.5 0 8.9 11<br>NO contact<br>0 2.0 6<br>NC contact XTCEXS...N_ XTCEXS...N_<br>0 2.8 6<br>NO contact NO contact<br>0 5.45 7.5 0 8.95 11<br>NC contact NC contact<br>0 3.6 7.5 0 7.1 11<br>XTCEXSBLN11 XTCEXSBLN11<br>NO contact NO contact<br>0 4.1 7.5 0 7.6 11<br>NC contact NC contact<br>0 4.95 7.5 0 8.45 11<br>**----- End of picture text -----**<br>
**Note:** The diagrams indicate the closing and travel of the contacts of the contactors and auxiliary contacts at no-load. Tolerances are not taken into consideration.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-110**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Electrical Life Curves**
## _**Normal Switching Duty**_
## **XTCE007B–XTCE170G**
**==> picture [221 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
kW A AC-3/400V<br>90 170 XTCE170G<br>75 150 XTCE150G<br>55 115 XTCE115G<br>45 95 XTCE095F<br>37 80 XTCE080F<br>30 65 XTCE065D<br>22 50 XTCE050D<br>18.5 40 XTCE040D<br>15 32 XTCE032C<br>11 25 XTCE025C<br>7.5 18 XTCE015B XTCE018C<br>5.5 12 XTCE012B<br>4 9 XTCE009B, XTMC9A<br>3 7 XTCE007B<br>5<br>4<br>XTMC9A<br>3<br>XTMC9A<br>2<br>0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10<br>Component Lifespan (millions of operations)<br> 50 – 60 Hz<br>Rated Operational Current I e<br>Rated Output of Three-phase Motors 50 – 60 Hz<br>**----- End of picture text -----**<br>
## **XTCE185H–XTCEC16R**
**==> picture [222 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
kW900 1600A XTCEC16R AC-3/400 V<br>560 1000 XTCEC10N<br>450 820 XTCE820N<br>400 750 XTCE750N<br>355 650 XTCE650N<br>315 580 XTCE580N<br>250 500 XTCE500M<br>200 400 XTCE400M<br>160 300 XTCE300L<br>132 250 XTCE250L<br>110 225 XTCE225H<br>90 185 XTCE185H<br>75 145<br>55 104<br>45 85<br>37 72<br>30 58<br>22 43<br>18.5 36<br>15 30<br>11 23<br>7.5 16<br>0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 3 4 5 6 8 10<br>Component Lifespan (millions of operations)<br> 50 – 60 Hz<br>Rated Operational Current I e<br>Rated Output of Three-phase Motors 50 – 60 Hz<br>**----- End of picture text -----**<br>
## _**Extreme Switching Duty**_
## **XTCE007B–XTCE170G**
**==> picture [221 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
kW A AC-4/400V<br>XTCE150G,<br>52 100 XTCE170G<br>47 90 XTCE115G<br>41 80 XTCE095F<br>33 66 XTCE080F<br>19 40 XTCE065D<br>17 35 XTCE050D<br>15 32 XTCE040D<br>9 20 XTCE032C<br>7. 5 17 XTCE025C<br>5.5 13<br>XTCE012B,<br>4 9 XTCE015B<br>3.5 8.3 XTCE009B<br>2.5 6.5 XTCE007B<br>5<br>4<br>3<br>XTMC9A<br>2<br>0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10<br>Component Lifespan (millions of operations)<br> 50 – 60 Hz<br>e<br>Rated Operational Current I<br>Rated Output of Three-phase Motors 50 – 60 Hz<br>**----- End of picture text -----**<br>
## **XTCE185H–XTCEC16R**
**==> picture [222 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
kW A AC-4/400 V<br>750 1280 XTCEC16R<br>450 800 XTCEC10N<br>355 656 XTCE820N<br>315 576 XTCE750N<br>280 512 XTCE650N<br>250 456 XTCE580N<br>200 360 XTCE500M<br>160 296 XTCE400M<br>132 240 XTCE300L<br>110 200 XTCE250L<br>90 164 XTCE225H<br>75 140 XTCE185H<br>55 104<br>45 85<br>37 72<br>30 58<br>22 43<br>18.5 36<br>15 30<br>11 23<br>7.5 16<br>5.5 12<br>4 8.8<br>3 6.5<br>2.2 5<br>1.5 3.5<br>0.01 0.02 0.03 0.04 0.06 0.1 0.2 0.3 0.4 0.6 1 2 3 4 5 6 8 10<br>Component Lifespan (millions of operations)<br> 50 – 60 Hz<br>e<br>Rated Operational Current I<br>Rated Output of Three-phase Motors 50 – 60 Hz<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-111**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Switching Duty for Non-Motor Loads**_
## **Three-Pole—XTCE007B–XTCEC20R**
**==> picture [220 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
20001800 XTCEC20RXTCEC16R AC-1/400 V<br>1400 XTCEC14P<br>9008001000850700 XTCE820N, XTCEC10NXTCE650XTCE500MN [XTCE580N] XTCE750N<br>500 XTCE400M<br>400 XTCE300L<br>350 XTCE250L<br>300 XTCE225H<br>275 XTCE185H<br>160 XTCE150G, XTCE170G<br>130 XTCE115G<br>110 XTCE095F<br>9080 XTCE065D XTCE080F<br>65 XTCE050D<br>50 XTCE040D<br>40 XTCE025C, XTCE032C<br>35 XTCE018C<br>20 XTMC9A<br>10<br>7<br>5<br>4<br>3<br>2<br>1<br>0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10<br>Component Lifespan (millions of operations)<br>XTCE007B, XTCE009B, XTCE012B, XTCE015B<br>Breaking Current A<br>**----- End of picture text -----**<br>
## **Four-Pole—XTCF020B–XTCF200G**
**==> picture [227 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC-1/400 V<br>200 XTCF200G<br>160 XTCF160G<br>125 XTCF125G<br>80 XTCF080D<br>63 XTCF063D<br>45 XTCF045C<br>32 XTCF032C<br>22 XTCF020B<br>0.1 0.2 0.4 0.6 1 2 4 6 10<br>Component Lifespan (millions of operations)<br>Operating characteristics:<br>Non-inductive and slightly inductive loads<br>Electrical characteristics:<br>Switch on: 1 x Rated current<br>Switch off: 1 x Rated current<br>Utilization category:<br>100% AC-1<br>Typical applications:<br>Electrical heating<br>Breaking Current A<br>**----- End of picture text -----**<br>
## _**Short-Time Loading**_
## **Three-Pole—XTCE007B–XTCEC20R**
**==> picture [235 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
A AC-1/400 V<br>700<br>600 XTCE065D<br>500 XTCE050D<br>450 XTCE040D<br>400<br>350 XTCE032C<br>300 XTCE025C<br>250 XTCE018C<br>200<br>150<br>XTCE012B,<br>120 XTCE015B<br>100 XTCE007B,<br>90 XTCE009B<br>70<br>50<br>40<br>30<br>20<br>15<br>2 3 5 7 10 20 30 50 70 100 200 300 500 700 900 Seconds<br>Duration of load 1 min 3 min 5 min 10 min 15 min<br>Short-time Current<br>**----- End of picture text -----**<br>
## **Three-Pole—XTCE080F–XTCEC16R**
**==> picture [234 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>19000 XTCEC16R AC-1/400 V<br>10000 XTCE820NXTCE750N XTCEC10N, XTCEC14P<br>8000 XTCE650N<br>XTCE580N<br>6000<br>XTCE500M<br>5000<br>XTCE400M<br>4000<br>XTCE300L<br>3000 XTCE250L<br>2500<br>2000 XTCE185H, XTCE225H<br>1800 XTCE115G,<br>1500 XTCE150G,<br>XTCE170G<br>1100 XTCE080F, XTCE095F<br>1000<br>700<br>500<br>400<br>300<br>200<br>2 3 5 7 10 20 30 50 70 100 200 300 500 700 900 Seconds<br>Duration of load 1 min 3 min 5 min 10 min 15 min<br>XTCEC20R<br>Short-time Current<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-112**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Maximum Operating Frequency—Related to Rating and Utilization Category (400V)**_
## **7 to 150 hp**
## **185 to 820 hp**
**==> picture [448 x 208] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ops./h Ops./h<br>6000 4000<br>3000 a<br>a b<br>4000 b 2000 c<br>c 1500 d<br>d<br>2000<br>1000<br>800<br>e 600<br>1000800 400500 e<br>600 300 f<br>200<br>400 150 g<br>100<br>200<br>50<br>0 10 20 30 40 50 60 70 80 90 100 %<br>100 PN [kW/hp]<br>0 10 20 30 40 50 60 70 80 90 100 %<br>PN [kW/hp]<br>**----- End of picture text -----**<br>
## **Utilization Category**[1]
||**Characteristic**|**Curve Above**||
|---|---|---|---|
|**Type**<br>XTCE007B–XTCE015B|**AC-1**<br>3|**AC-3**<br>1|**AC-2, AC-4**<br>5|
|XTCE018C–XTCE032C|3|2|5|
|XTCE040D–XTCE065D|3|2|5|
|XTCE080F–XTCE150G|3|4|5|
## **Utilization Category**[1]
||**Characteristic**|**Curve Above**||
|---|---|---|---|
|**Type**<br>XTCE185H|**AC-1**<br>2|**AC-3**<br>1|**AC-2, AC-4**<br>6|
|XTCE225H|2|1|6|
|XTCE250L|2|1|6|
|XTCE300L|3|2|7|
|XTCE400M|3|2|7|
|XTCE500M|3|2|7|
|XTCE580N|3|4|5|
|XTCE650N|3|4|5|
|XTCE750N|3|4|5|
|XTCE820N|3|4|5|
## _**Note**_
- 1 P N = max. motor rating (kW/hp) of the relevant contactor. ops./h = max. number of operations per hour.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-113**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Dimensions**
Approximate Dimensions in mm [in]
## _**XTCE Contactors (Three-Pole)**_
## **Frame B, XTCE007B and XTCE015B Contactors with Screw Terminals (7–15A) XTCF020B**
**==> picture [455 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
36 [1.42]<br>4 x M4 Dia.<br>68<br>18 [2.68] 60 [2.36]<br>[.71]<br>45<br>[1.77]<br>Auxiliary C 35 [1.38]<br>Type<br>8.7 [.34 ] 3.2 [.13]<br>Typ. XTCEXFAC_ 117 [4.61]<br>5.1 [.20] 6.5 [.26]<br>XTCEXFCC_ 117 [4.61]<br>45 [1.77] 75 [2.95]<br>XTCEXFATC_ 125 [4.92]<br>C<br>**----- End of picture text -----**<br>
**Frame B, XTCEC007B–XTCEC012B Contactors with Spring Cage Terminals (7–12A)**
**==> picture [458 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
68<br>26.4 [2.68] 4 x M4 Dia.<br>[1.04]<br>52.3<br>[2.06] 60 [2.36]<br>1.8 3.2 [.13]<br>[.07]<br>1.8 6.5 [.26]<br>[.07] 35 [1.38]<br>8.7 [.34] 75 [2.95]<br>Typ.<br>5.1 [.20] 125.2 [4.93]<br>45 [1.77]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-114**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frame C, XTCE018C–XTCE032C Contactors (18–32A)**
**==> picture [494 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
71<br>[2.80]<br>38<br>2 x M4 Dia.<br>[1.50] 85<br>[3.46]<br>60.4<br>[2.38]<br>75 [2.95]<br>4.5 [.17] 4.8 [.19] 4.5 [.17]<br>17.7 [.70] 6.5 [.26]<br>[.25]6.4 11.6 [.42]10.6 97.4 [3.83]138.7 [5.46] 35 [1.38]<br>[.46]<br>11.6<br>[.46]<br>45 [1.77] Note: Sideways distance to grounded parts: 6 mm [.39 in]<br>**----- End of picture text -----**<br>
## **Frame D, XTCE040D–XTCE072D Contactors (72A)**
**==> picture [488 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 x M4 Dia.<br>104<br>57 [4.09] 105 [4.13]<br>[2.24]<br>86.4<br>[3.40]<br>4.7 [.19] 45 [1.77]<br>34.4 [1.35]<br>6.9 [.27]<br>55 [2.17] 113.8 [4.48]<br>132.1 [5.20]<br>Note: Sideways distance to<br>146.8 [5.78] grounded parts: 6 mm [.39 in]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-115**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frames F–G, XTCE080F–XTCE170G Contactors (80–170A)**
||||||76.5 [3.01]<br>57 [2.24]<br>|76.5 [3.01]<br>57 [2.24]<br>|76.5 [3.01]<br>57 [2.24]<br>|76.5 [3.01]<br>57 [2.24]<br>|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||156 [6.14]||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||82.5 [3.25]<br>85.5 [3.37]<br>~~1~~42 [5.59]<br>~~1~~60 [630||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||90 [3.54|]<br>111 [437]|||||||||||||||
|**rames H–M, XTCE185H–XTCE570M**<br>.<br>**W**<br>**W1**<br>**W2**<br>W3<br>H1 H<br>W4<br>W<br>11 [.43] Dia.<br>W1<br>2|||||||||||||||||
||||||||||||**(185–580A)**<br>.<br>**W4**<br>**H**<br>**H1**<br><br>8 [.31]<br>W2<br>M6 Dia.<br>D1||||||
||11 [.43]<br>|W<br>Dia.<br>1|||||||||||||||
|2|||H1||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
|||||||||D2|||||||||
|||W3<br>W4|||||||||||||||
||**W**||||||||||||||||
||||||||**W3**||||||||||
|**ame H**|140 [5.|51]<br>160 [6.30]<br>120 [4.72]|||||20 [.79]||||41 [1.61]<br>180 [7.09]<br>165 [6.50]|||||190 [7.48]<br>160 [6.30]<br>158 [6.22]<br>4 [.16]<br>83 [3.27]|
|**ame L**|140 [5.|51]<br>160 [6.30]<br>120 [4.72]|||||20 [.79]||||48 [1.89]<br>180 [7.09]<br>164 [6.46]|||||189 [7.44]<br>160 [6.30]<br>208 [8.19]<br>5 [.20]<br>140 [5.51]|
|**ame M**|160 [6.<br>160 [6.|30]<br>180 [7.09]<br>130 [5.12]|||||25 [.98]||||48 [1.89]<br>200 [7.87]<br>184 [7.24]|||||209 [8.23]<br>180 [7.09]<br>216 [8.50]<br>6 [.24]<br>140 [5.51]|
|||30]<br>180 [7.09]<br>130 [5.12]|||||38 [1.50]||||57 [2.24]<br>200 [7.87]<br>189 [7.44]|||||219 [8.62]<br>180 [7.09]<br>216 [8.50]<br>6 [.24]<br>140 [5.51]|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-116**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frame N, XTCE580N–XTCEC10N Contactors (580–1000A)**
**==> picture [427 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|A Dia.|
|M6|
|Dia.|
|232|256|215|
|[9.13]|[10.08]|H|[8.46]|
|165 [6.50]|
|80|
|W|D1|
|[3.15]|
|250 [9.84]|140 [5.51]|
|270 [10.63]|232 [9.13]|
|W|H|D1|A (Dia.)|
|XTCE580N|45 [1.77]|296 [11.65]|6 [.24]|13.5 [.53]|
|XTCE650N|45 [1.77]|296 [11.65]|6 [.24]|13.5 [.53]|
|XTCE750N|45 [1.77]|296 [11.65]|6 [.24]|13.5 [.53]|
|XTCE820N|45 [1.77]|296 [11.65]|6 [.24]|13.5 [.53]|
|XTCEC10N|45 [1.77]|296 [11.65]|10 [.40]|13.5 [.53]|
**----- End of picture text -----**<br>
**Frame P, XTCEC14P Contactor (1400A, AC-1)**
**==> picture [447 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
M6 Dia.<br>210 342<br>[8.27] [13.46]<br>256 232 215<br>[10.08] [9.13] [8.46]<br>308<br>[12.13]<br>165 [6.50]<br>60 14 [.55] 130 [5.12] 10<br>[2.36] Dia. [.39]<br>100 100 232 [9.13]<br>[3.94] [3.94]<br>260 [10.24]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-117**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frame R, XTCEC16R, XTCEC20R Contactors**
**==> picture [390 x 361] intentionally omitted <==**
**----- Start of picture text -----**<br>
210 392<br>[8.27] [15.43]<br>272 300<br>10.71] [11.81]<br>352<br>[13.86]<br>150 [5.91] 10 [.39]<br>14 [.55] 40 252 [9.92]<br>Dia. [1.57]<br>80 [3.15] 80 [3.15]<br>150 [5.90] 125 [4.92]<br>172.5 [6.79] 172.5 [6.79]<br>515 [20.28]<br>M6 Dia.<br>270<br>[10.63]<br>430 [16.93]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-118**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**XTCF Contactors (Four-Pole)**_
## **Frame B, XTCF020B Contactors**
**==> picture [445 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 x M4<br>[0.71]18.0 [1.77]45.0 [2.36]60.0<br>68.0<br>[2.68]<br>6.5<br>[0.26]<br>36.0 3.2 35.0<br>[1.42] [0.13] 75.0 [1.38]<br>45.0 [2.95]<br>[1.77] 117.0<br>[4.61]<br>**----- End of picture text -----**<br>
## **Frame C, XTCF032C–XTCF045C Contactors**
**==> picture [452 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
85.0 2 x M4<br>60.0 [3.35]<br>75.0<br>38.0 [2.36]<br>[2.95]<br>[1.50] 71.0<br>[2.80]<br>6.5<br>58.0 [0.26] 35.0<br>[2.28] 4.5 [1.38]<br>[0.18] 97.4<br>[3.83]<br>138.0<br>[5.43]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-119**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frame D, XTCF063D–XTCF080D Contactors**
**==> picture [441 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
115.0 2 x M4<br>86.4<br>[4.53]<br>57.0 [3.40] 105.0<br>104.0<br>[2.24] [4.13]<br>[4.09]<br>6.9<br>45.0<br>74.0 [0.27]<br>4.7 [1.77]<br>[2.91]<br>[0.19] 114.0<br>85.0 [4.49]<br>[3.35] 132.1<br>[5.20]<br>147.0<br>[5.79]<br>**----- End of picture text -----**<br>
## **Frame G, XTCF125G–XTCF200G Contactors**
**==> picture [463 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 x M6<br>170.0<br>[6.69]<br>57.0 156.0 156.0<br>[2.24] [6.14] [6.14]<br>122.0<br>[4.80] 82.5 70.0<br>133.0 [3.25] [2.76]<br>[5.24] 85.5<br>[3.37]<br>142.0<br>[5.59]<br>160.0<br>[6.30]<br>175.0<br>[6.89]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-120**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**XTAE Starters with XTOB Overload Relay**_
**Frame B, XTAE007B–XTAE015B Starters with XTOB (7–12A)**
**==> picture [213 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting<br>45.3 Holes for 117.1<br>[1.78] M4 or #8 [4.61]<br>Screws<br>35 (4 Places) 75.8<br>[1.38] [2.98]<br>60<br>[2.36]<br>117.8<br>[4.64]<br>83.3 [3.28]<br>88.4 [3.48]<br>To Reset<br>**----- End of picture text -----**<br>
**Frame C, XTAE018C–XTAE032C Starters with XTOB (18–32A)**
**Frame D, XTAE040D–XTAE065D Starters with XTOB (40–65A)**
**==> picture [229 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
60 Mounting 146<br>[2.36] Holes for [5.75]<br>M4 or #8<br>45 Screws 132.5<br>[1.77] (4 Places) [5.22]<br>105<br>[4.13]<br>174<br>[6.85]<br>98 [3.86]<br>To Reset<br>93.6 [3.69]<br>**----- End of picture text -----**<br>
**==> picture [225 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
45 Mounting 139.8<br>[1.77] Holes for [5.50]<br>M4 or #8<br>35 Screws 97.8<br>[1.38] (2 Places) [3.85]<br>75<br>[2.95]<br>136.4<br>[5.37]<br>100.2 [3.94]<br>105.3 [4.15]<br>To Reset<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-121**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
Approximate Dimensions in mm [in]
## **Frames F–G, XTAE080F–XTAE150G Starters with XTOB (80–150A)**
**==> picture [355 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
90 [3.54] 160 [6.30]<br>70 [2.76] 150 [5.91]<br>156 57 170<br>[6.14] [2.24] [6.69]<br>277<br>[10.91]<br>91<br>[3.58] 74<br>[2.91]<br>95 [3.74]<br>7 [.276] 100 [3.94]<br>Dia. 118 [4.65] 134 [5.28]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-122**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## Approximate Dimensions in mm [in]
## _**XTAE Starters with XTOE Overload Relay**_
**Frames F–G, XTAE080F–XTAE115G Starters with XTOE (20–100A)**
## **Frame B, XTAE007B–XTAE012B Starters with XTOE (0.35–20A)**
**==> picture [239 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
117.0 [4.61] Mounting 45.3 [1.78]<br>75.8 [2.98] Holes for 35.0 [1.38]<br>M4 or #8<br>Screws<br>(4 places)<br>60.0<br>[2.36]<br>100.6<br>143.2 [3.96]<br>[5.64] 1.2 Nm<br>[11 lb-in]<br>18.2 [0.71]<br>Trip/Test<br>102.7 [4.04] 10.6 [0.42]<br>110.4 [4.35] Reset<br>**----- End of picture text -----**<br>
**==> picture [234 x 232] intentionally omitted <==**
**----- Start of picture text -----**<br>
111.8<br>[4.40]<br>90.0<br>[3.54]<br>Mtg.<br>[0.31]7.8 [2.76]70.0 Mtg. Holes for(4) M6 or #10 175.0 [6.89]<br>Screws 160.0 [6.30]<br>156.0<br>[6.14]<br>222.3 Mtg. [6.59] [167.3]<br>[8.75] Mtg.<br>To Reset<br>291.1<br>[11.46]<br>108.4<br>[4.27]<br>Mtg.<br>41.2 [1.62] Mtg. 1 32.4 [5.21]<br>Mtg. Holes To Reset<br>for (2) M4 56.0 [2.20] 140.2 [5.52]<br>or #8 Screws<br>**----- End of picture text -----**<br>
**Frame C, XTAE018C–XTAE032C Starters with XTOE (0.35–45A)**
**==> picture [236 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
140.0 [5.50]<br>45.0 [1.77]<br>98.0 [3.80]<br>35.0 [1.38]<br>Mounting<br>Holes for<br>M4 or #8<br>Screws 75.0<br>(2 places) [2.95]<br>117.3<br>161.0 [4.62]<br>[6.30]<br>2.5–3.0 Nm<br>[22–26 lb-in]<br>18.2 [0.71]<br>102.7 [4.04] Trip/Test<br>110.4 [4.35] 10.6 [0.42]<br>Reset<br>**----- End of picture text -----**<br>
**Frame G, XTAE115G–XTAE150G Starters with XTOE (100–175A)**
**==> picture [498 x 308] intentionally omitted <==**
**----- Start of picture text -----**<br>
M6 [#10] Screws<br>[22–26 lb-in]<br>70.0<br>[2.76] Terminal<br>156.0 Torque:<br>18.2 [0.71] [6.14] 14 Nm<br>102.7 [4.04] Trip/Test [124 lb-in]<br>110.4 [4.35] 10.6 [0.42] 21.3 [0.84]<br>Reset<br>345.0<br>[13.6]<br>Frame D, XTAE040D–XTAE065D Starters<br>with XTOE (20–100A) 152.0<br>[6.00]<br>45.0 [1.77] Mtg. 77.0<br>55.0 [2.17] 5.0 [3.00]<br>5.0 [0.20] [0.20]<br>Mtg. Holes for<br>146.1 [5.75] 18.2 [0.71] Trip/Test 157.0 [6.18]<br>5.0 [0.20] (4) #8 Screws or<br>M4 Screws 10.6 [0.42] Reset 161.0 [6.30]<br>36.0 [1.42]<br>89.0 110.0 [4.30]<br>105.0 [3.50]<br>[4.13]<br>Mtg. 159.7<br>[6.29]<br>213.6 To Reset<br>[8.41]<br>38.7 [1.52]<br>To Reset 136.2 [5.36]<br>To Reset<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-123**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**XTCR Reversing Combination**_
## **Frames B–D**
|H||||||||
|---|---|---|---|---|---|---|---|
|||||||||
|||||||||
|W||||||||
|**A)**<br> <br>**H**<br>**D**<br><br>68<br>2.68]<br>117<br>[4.61]<br> <br>[<br>||**Frame C (18–32A)**<br>**W**<br>**H**<br>|||**D**<br>|||
|||90<br>3.54]<br>85<br>[3.34]|||138<br>[5.43]||110<br>[4.33]<br>115<br>[4.53]<br>146.8<br>[5.78]|
## **Frames F–G**
**==> picture [394 x 294] intentionally omitted <==**
**----- Start of picture text -----**<br>
299 314<br>[11.77] [12.36]<br>176 [6.93] M6<br>196 [7.72] 183 [7.20]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-124**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**Star-Delta Combination**_
## **Frames B–D**
|||||||H||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||W||||||D||||
|**me B**<br>**H**|**D**<br>|||**Frame C**<br>**W**<br>**H**<br>158<br>[6.22]<br>85<br>[3.34]|||**D**|**Frame D**<br>**W**<br>**H**<br>188<br>[7.40]<br>115<br>[4.53]<br>||||
|]<br>68<br>[2.|68]<br>117<br>[4.61]||||||138<br>[5.43]||||146.8<br>[5.78]|
## **Frames F–G**
**==> picture [486 x 294] intentionally omitted <==**
**----- Start of picture text -----**<br>
299 314<br>[11.77] [12.36]<br>144 [5.67] 144 [5.67] M6<br>308 [12.13] 183 [7.20]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-125**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**Mechanical Interlock**_
**Frames H–M—XTCEXMLM**
**==> picture [83 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
15<br>[.59]<br>**----- End of picture text -----**<br>
## **XTCEXMLN**
**==> picture [222 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
20<br>515 [20.28]<br>[.79]<br>430 [16.93]<br>270<br>[10.63]<br>300<br>[11.81]<br>9 [.35]<br>**----- End of picture text -----**<br>
## _**Contactor with Terminal Shroud**_
**Frames L–N Contactors, XTCE250L–XTCEC10N, with Terminal Shroud XTLEXTS**
||||||||**H**<br>404<br>[15.91]<br>H|**XTCE500M, XTCE570M**<br>**W**<br>**H**<br>174<br>[6.85]<br>426<br>[16.77]|**XTCE580N, XTCE650N,**<br>**XTCE750N, XTCE820N,**<br>**XTCEC10N**<br>**W**<br>**H**|
|---|---|---|---|---|---|---|---|---|---|
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|**TCE250L**<br>**W**|**H**||||**XTCE400M**<br>**W**|||||
|50<br>5.91]|384<br>[15.12]||||150<br>[5.91]||||236<br>[9.29]<br>506<br>[19.92]|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-126**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**Suppressor**_
## **XTCE_ Suppressor**
|||D<br>H2<br>H3<br>H1||
|---|---|---|---|
|W2<br>W1||||
|||||
|**TCEXRSB_**<br>**TCEXVSB_**<br>**TCEXVSLB_**<br>**TCEXDSB_**<br>25<br>[.98]<br>9.2<br>[.36]<br>25.9<br>[1.02]<br>28<br>[1.10]<br>32<br>[1.26]<br>9<br>[.35]||||
|**TCEXRSC_**<br>**TCEXVSC_**<br>**TCEXVSLC_**<br>25<br>[.98]<br>9.2<br>[.36]<br>16<br>[.63]<br>28<br>[1.10]<br>32<br>[1.26]<br>9<br>[.35]||||
|**TCEXRSF_**<br>**TCEXVSF_**<br>**TCEXVSLF_**<br>25<br>[.98]<br>20<br>[.79]<br>18.5<br>[.73]<br>28<br>[1.10]<br>32<br>[1.26]<br>9<br>[.35]||||
## _**Cable Terminal Block**_
**==> picture [226 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTCEXTLA<br>H<br>135 222<br>[5.31] [8.74] 30<br>[1.18]<br>H<br>XTCE250L 198 [7.80]<br>XTCE400M 218 [8.58]<br>**----- End of picture text -----**<br>
## _**Flat Strip Conductor Terminals**_
## **XTCEXTFB**
**==> picture [138 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
W<br>H<br>**----- End of picture text -----**<br>
||**W**||**H**||
|---|---|---|---|---|
|**XTCE500M–XTCE570M**<br>**XTCE750N–XTCE820N**|171<br>231|[6.73]<br>[9.09]|232<br>310|[9.13]<br>[12.20]|
## _**Three-Phase Commoning Link**_
## **Frame B**
**==> picture [218 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
W 12.5<br>[.49]<br>18.1 [.71]<br>13.1 [.52]<br>**----- End of picture text -----**<br>
||**W**||
|---|---|---|
|**XTCEXCLK3B**|112|[4.41]|
|**XTCEXCLK4B**|157|[6.18]|
|**XTCBXCLK5B**|202|[7.95]|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-127**
1.1
_**XT**_ IEC Power Control
## IEC Contactors and Starters
**1**
**==> picture [82 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTOB, XTOT Overload Relays<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-129**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-130**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-133**|
|Technical Data and Specifications . . . . . . . . . .|**V5-T1-136**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-138**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors. . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .|**V5-T1-217**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . .|**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## **Thermal Overload Relays**
## **Product Description**
The _**XT**_ line of IEC motor thermal overload relays provides an efficient motor protection solution, available up to 630A. XTOB units can be directly mounted to the contactor or mounted separately.
## **Features and Benefits**
- Direct connect up to 250A
- Stand alone and CT type up to 630A
- Large thermal overcurrent range
- Test button
- Manual/automatic selectable reset
## **Standards and Certifications**
- IEC EN 60947
- CE approved
- UL
- CSA
- ATEX
- RoHS
- NO-NC auxiliary as standard
- Class 10A (to 250A)
- Class 30 (CT type)
## _**Notes**_
Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. See MN03402001E for more information on overload relays for Frames B–G. Trip Class: 10A
Suitable for protection of EEx e-motors. EC prototype test certificate available upon request. See manuals MN03402001E and MN03407001E, **Page V5-T1-133** .
## _**Instructional Leaflets**_
Pub51221 XTOB, D Frame overload relays (inside of packaging) Pub51222 XTOB, B–C Frame overload relays (inside of packaging)
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-128**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **IEC Overload Relays**
**XT OB P16 B C1 S Mounting Trip Class Blank** = Direct to contactor **Overload Release Frame Size C1** = Class 10A (XTOB) **S** = Separate mount **Frame G Designation C3** = Class 30 (XTOT) **035** = 25–35A **B** = 45 mm **050** = 35–50A **C** = 45 mm **070** = 50–70A **D** = 55 mm **100** = 70–100A **G** = 90 mm **125** = 95–125A **L** = 140 mm **150** = 120–150A **Blank** = XTOT only
|||||||||
|---|---|---|---|---|---|---|---|
|||||||||
|**Device Type**||||||||
|**_XT_**=**_XT_**line of IEC control||||||||
||||**Overload Release**|||||
|**Type**||<br><br><br><br><br><br><br><br><br><br><br><br><br> <br><br><br><br><br><br><br><br><br><br><br><br><br><br> <br><br><br><br><br><br><br><br> <br><br><br><br>|**Frame B**<br>**P16** = 0.1–0.16A<br>**P24** = 0.16–0.24A<br>**P40** = 0.24–0.4A<br>**P60** = 0.4–0.6A<br>**001**<br>= 0.6–1A<br>**1P6** = 1.0–1.6A<br>**2P4** = 1.6–2.4A<br>**004**<br>= 2.4–4A<br>**006**<br>= 4–6A<br>**010**<br>= 6–10A<br>**012**<br>= 9–12A<br>**016**<br>= 12–16A<br>**Frame C**<br>**P16** = 0.1–0.16A<br>**P24** = 0.16–0.24A<br>**P40** = 0.24–0.4A<br>**P60** = 0.4–0.6A<br>**001**<br>= 0.6–1A<br>**1P6** = 1.0–1.6A<br>**2P4** = 1.6–2.4A<br>**004**<br>= 2.4–4A<br>**006**<br>= 4–6A<br>**010**<br>= 6–10A<br>**016**<br>= 12–16A<br>**024**<br>= 16–24A<br>**032**<br>= 24–32A<br>**Frame D**<br>**010**<br>= 6–10A<br>**016**<br>= 12–16A<br>**024**<br>= 16–24A<br>**040**<br>= 24–40A<br>**057**<br>= 40–57A<br>**065**<br>= 50–65A<br>**075**<br>= 65–75A<br>**Frame F**<br>**035**<br>= 25–35A<br>**050**<br>= 35–50A<br>**070**<br>= 50–70A<br>**100**<br>= 70–100A||**Frame G**<br>**035**<br>= 25–35A<br>**050**<br>= 35–50A<br>**070**<br>= 50–70A<br>**100**<br>= 70–100A<br>**125**<br>= 95–125A<br>**150**<br>= 120–150A<br>**175**<br>= 145–175A<br>**Frame H**<br>**070**<br>= 50–70A<br>**100**<br>= 70–100A<br>**125**<br>= 95–125A<br>**160**<br>= 120–160A<br>**220**<br>= 160–220A<br>**250**<br>= 200–250A<br>**Frame L**<br>**070**<br>= 50–70A<br>**100**<br>= 70–100A<br>**125**<br>= 95–125A<br>**160**<br>= 120–160A<br>**220**<br>= 160–220A<br>**250**<br>= 200–250A<br>**300**<br>= 200–300A<br>**Frame M**<br>**063**<br>= 42–63A<br>**090**<br>= 60–90A<br>**125**<br>= 85–125A<br>**160**<br>= 110–160A<br>**240**<br>= 160–240A<br>**290**<br>= 190–290A<br>**400**<br>= 170–400A<br>**540**<br>= 360–540A<br>**Frame N**<br>**063**<br>= 42–63A<br>**090**<br>= 60–90A<br>**125**<br>= 85–125A<br>**160**<br>= 110–160A<br>**240**<br>= 160–240A<br>**290**<br>= 190–290A<br>**400**<br>= 170–400A<br>**540**<br>= 360–540A<br>**630**<br>= 420–630A|||
|**OB**<br>= Bimetallic overload relay<br>**OT**<br>= Current transformer overload relay||||||||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-129**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Product Selection**
## **Frame B**
## **Overload Relay, Direct Mount—Frame B**
||||||||||||||||**Short-Circuit Protection (A)**|**Short-Circuit Protection (A)**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||**For Use**<br>**with**|**Fuse**<br>**Type 1**|**Type 2**|**Maximum**|||
|**Overload**|**Contact**||||||||||||**Contact**|**Contactor**|**Coordination,**|**Coordination,**|**Circuit**|**CEC/NEC**||
|**Releases, Ir**<br>**Sequence**<br>0.1–0.16<br>0.16–0.24<br>0.24–0.4<br>0.4–0.6<br>2 4 6 9896A214/<br>22<br>97 95<br>~~——~~|||||||||||||**Configuration**<br>1NO-1NC<br>1NO-1NC<br>1NO-1NC<br>1NO-1NC|**Amp Range**<br>7–15A<br>7–15A<br>7–15A<br>7–15A|**gG/gL**<br>25<br>25<br>25<br>25|**gG/gL**<br>0.5<br>1<br>2<br>4|**Breaker**<br>25<br>25<br>25<br>25|**Fuse**<br>3<br>3<br>3<br>3|**Catalog Number**<br>**XTOBP16BC1**<br>**XTOBP24BC1**<br>**XTOBP40BC1**<br>**XTOBP60BC1**|
|0.6–1|||||||||||||1NO-1NC|7–15A|25|4|25|3|**XTOB001BC1**|
|1–1.6|||||||||||||1NO-1NC|7–15A|25|6|25|6|**XTOB1P6BC1**|
|1.6–2.4|||||||||||||1NO-1NC|7–15A|25|10|25|6|**XTOB2P4BC1**|
|2.4–4|||||||||||||1NO-1NC|7–15A|25|16|25|15|**XTOB004BC1**|
|4–6|||||||||||||1NO-1NC|7–15A|25|20|25|20|**XTOB006BC1**|
|6–10|||||||||||||1NO-1NC|7–15A|50|25|25|35|**XTOB010BC1**|
|9–12|||||||||||||1NO-1NC|9–15A|50|25|25|45|**XTOB012BC1**|
|12–16|||||||||||||1NO-1NC|12–15A|50|25|30|45|**XTOB016BC1**|
## **Frame C**
## **Overload Relay, Direct Mount—Frame C**
|||||||||||||||**Short-Circuit Protection (A)**|**Short-Circuit Protection (A)**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||**For Use**|**Fuse**|||||
||||||||||||||**with**|**Type 1**|**Type 2**|**Maximum**|||
|**Overload**|**Contact**|||||||||||**Contact**|**Contactor**|**Coordination,**|**Coordination,**|**Circuit**|**CEC/NEC**||
|**Releases, Ir**<br>**Sequence**<br>**Configuration**<br>**Amp Range**<br>**Catalog Number**<br>**Breaker**<br>**Fuse**<br>**gG/gL**<br>**gG/gL**<br>0.1–0.16<br>1NO-1NC<br>18–32A<br>25<br>0.5<br>25<br>3<br>**XTOBP16CC1**<br>0.16–0.24<br>1NO-1NC<br>18–32A<br>25<br>1<br>25<br>3<br>**XTOBP24CC1**<br>0.24–0.4<br>1NO-1NC<br>18–32A<br>25<br>2<br>25<br>3<br>**XTOBP40CC1**<br>0.4–0.6<br>1NO-1NC<br>18–32A<br>25<br>4<br>25<br>3<br>**XTOBP60CC1**<br>2 4 6 989614/<br>22<br>97 95<br>~~——ae~~|||||||||||||||||||
|0.6–1<br>1–1.6||||||||||||1NO-1NC<br>1NO-1NC|18–32A<br>18–32A|25<br>25|4<br>6|25<br>25|3<br>6|**XTOB001CC1**<br>**XTOB1P6CC1**|
|1.6–2.4||||||||||||1NO-1NC|18–32A|25|10|25|6|**XTOB2P4CC1**|
|2.4–4||||||||||||1NO-1NC|18–32A|25|16|25|15|**XTOB004CC1**|
|4–6||||||||||||1NO-1NC|18–32A|25|20|25|20|**XTOB006CC1**|
|6–10||||||||||||1NO-1NC|18–32A|50|25|25|25|**XTOB010CC1**|
|10–16||||||||||||1NO-1NC|18–32A|63|35|30|25|**XTOB016CC1**|
|16–24<br>24–32||||||||||||1NO-1NC<br>1NO-1NC|18–32A<br>25–32A|100<br>125|35<br>63|30<br>30|25<br>25|**XTOB024CC1**<br>**XTOB032CC1**|
|32–38||||||||||||1NO-1NC|32–38A|125|63|30|25|**XTOB032CC1**|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-130**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **Frame D**
## **Frames F–G**
## **Overload Relay, Direct Mount—Frame D**
|||||||||||||**Short-Circuit Protection (A)**|**Short-Circuit Protection (A)**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||**For Use**<br>**with**|**Fuse**<br>**Type 1**|**Type 2**|**Maximum**|||
|**Overload**<br>**Releases, Ir**|**Contact**<br>**Sequence**|||||||||**Contact**<br>**Configuration**|**Contactor**<br>**Amp Range**|**Coordination,**<br>**gG/gL**|**Coordination,**<br>**gG/gL**|**Circuit**<br>**Breaker**|**CEC/NEC**<br>**Fuse**|**Catalog Number**|
|6–10<br>10–16<br>16–24|2 4 6 98 96<br>97 95<br>~~sot}~~|||||||||1NO-1NC<br>1NO-1NC<br>1NO-1NC|40–72A<br>40–72A<br>40–72A|50<br>63<br>63|25<br>35<br>50|25<br>25<br>30|25<br>25<br>25|**XTOB010DC1**<br>**XTOB016DC1**<br>**XTOB024DC1**|
|24–40||||||||||1NO-1NC|40–72A|125|63|125|125|**XTOB040DC1**|
|40–57||||||||||1NO-1NC|50–72A|160|80|150|150|**XTOB057DC1**|
|50–65||||||||||1NO-1NC|65–72A|160|100|150|200|**XTOB065DC1**|
|65–75||||||||||1NO-1NC|72A|200|125|150|200|**XTOB075DC1**|
## **Overload Relay, Direct Mount—Frames F–G**
**1**
||||||||||||||**Short-Circuit Protection (A)**|**Short-Circuit Protection (A)**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||**For Use**<br>**with**|**Fuse**<br>**Type 1**|**Type 2**|**Maximum**|||
|**Overload**|**Contact**||||||||||**Contact**|**Contactor**|**Coordination,**|**Coordination,**|**Circuit**|**CEC/NEC**||
|**Releases, Ir**|**Sequence**||||||||||**Configuration**|**Amp Range**|**gG/gL**|**gG/gL**|**Breaker**|**Fuse**|**Catalog Number**|
|25–35||||||||97 95|||1NO-1NC|80–170A|125|100|125|125|**XTOB035GC1**|
|35–50<br>1NO-1NC<br>80–170A<br>160<br>125<br>150<br>200<br>**XTOB050GC1**<br>50–70<br>1NO-1NC<br>80–170A<br>250<br>160<br>150<br>200<br>**XTOB070GC1**<br>70–100<br>1NO-1NC<br>80–170A<br>315<br>200<br>400<br>400<br>**XTOB100GC1**<br>2 4 6 98 96<br>~~OE~~||||||||||||||||||
|95–125|||||||||||1NO-1NC|80–170A|315|200|500|400|**XTOB125GC1**|
|120–150|||||||||||1NO-1NC|80–170A|315|200|600|600|**XTOB150GC1**|
|145–175|||||||||||1NO-1NC|150–170A|315|200|600|600|**XTOB175GC1**|
## **Frames F–G**
## **Overload Relay, Separate Mount—Frames F–G**
||||||||||||||**Short-Circuit Protection (A)**|**Short-Circuit Protection (A)**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||**For Use**<br>**with**|**Fuse**<br>**Type 1**|**Type 2**|**Maximum**|||
|**Overload**|**Contact**||||||||||**Contact**|**Contactor**|**Coordination,**|**Coordination,**|**Circuit**|**CEC/NEC**||
|**Releases, Ir**<br>**Sequence**<br>**Configuration**<br>**Amp Range**<br>**Catalog Number**<br>**Breaker**<br>**Fuse**<br>**gG/gL**<br>**gG/gL**<br>25–35<br>1NO-1NC<br>80–170A<br>125<br>100<br>125<br>125<br>**XTOB035GC1S**<br>35–50<br>1NO-1NC<br>80–170A<br>160<br>125<br>150<br>200<br>**XTOB050GC1S**<br>50–70<br>1NO-1NC<br>80–170A<br>250<br>160<br>150<br>200<br>**XTOB070GC1S**<br>2 4 6 98 96<br>97 95<br>~~——<=$$|-—_-~~||||||||||||||||||
|70–100|||||||||||1NO-1NC|80–170A|315|200|400|400|**XTOB100GC1S**|
|95–125<br>120–150|||||||||||1NO-1NC<br>1NO-1NC|80–170A<br>80–170A|315<br>315|250<br>250|500<br>600|400<br>600|**XTOB125GC1S**<br>**XTOB150GC1S**|
|145–175|||||||||||1NO-1NC|150–170A|315|250|600|600|**XTOB175GC1S**|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-131**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame H**
## **Overload Relay, Separate Mount—Frame H**
## **Short-Circuit Protection (A)**
||||||||||||**For Use**<br>**with**|**Fuse**<br>**Type 1**|**Type 2**|**Maximum**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Overload**<br>**Releases, Ir**|**Contact**<br>**Sequence**|||||||||**Contact**<br>**Configuration**|**Contactor**<br>**Amp Range**|**Coordination,**<br>**gG/gL**|**Coordination,**<br>**gG/gL**|**Circuit**<br>**Breaker**|**CEC/NEC**<br>**Fuse**|**Catalog Number**|
|50–70<br>70–100|1||3||5 97 95||5 97 95|||1NO-1NC<br>1NO-1NC|185–250A<br>185–250A|250<br>315|160<br>200|150<br>400|200<br>400|**XTOB070HC1**<br>**XTOB100HC1**|
|95–125|2||4||6||98 96|||1NO-1NC|185–250A|315|250|500|400|**XTOB125HC1**|
|120–160||||||||||1NO-1NC|185–250A|400|250|600|600|**XTOB160HC1**|
|160–220||||||||||1NO-1NC|185–250A|4001|3151|600|800|**XTOB220HC1**|
|200–250||||||||||1NO-1NC|225–250A|4001|3151|600|700|**XTOB250HC1**|
## **Frame L**
## **Overload Relay, Separate Mount—Frame L**
||||||||||||**For Use**|**Short-Circuit Protection (A)**<br>**Fuse**|**Short-Circuit Protection (A)**<br>**Fuse**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Overload**<br>**Releases, Ir**|**Contact**<br>**Sequence**|||||||||**Contact**<br>**Configuration**|**with**<br>**Contactor**<br>**Amp Range**|**Type 1**<br>**Coordination,**<br>**gG/gL**|**Type 2**<br>**Coordination,**<br>**gG/gL**|**Maximum**<br>**Circuit**<br>**Breaker**|**CEC/NEC**<br>**Fuse**|**Catalog Number**|
|50–70|1||3||5 97 95||5 97 95|||1NO-1NC|185–250A|250|160|150|200|**XTOB070LC1**|
|70–100||||||||||1NO-1NC|185–250A|315|200|400|400|**XTOB100LC1**|
|95–125|2||4||6||98 96|||1NO-1NC|185–250A|315|250|500|400|**XTOB125LC1**|
|120–160<br>160–220||||||||||1NO-1NC<br>1NO-1NC|185–250A<br>185–250A|400<br>4001|250<br>3151|600<br>600|600<br>800|**XTOB160LC1**<br>**XTOB220LC1**|
|200–250||||||||||1NO-1NC|225–250A|4001|3151|600|700|**XTOB250LC1**|
|200–300||||||||||1NO-1NC|225–300A|6301|6301|600|700|**XTOB300LC1**|
## **Frames M-N**
**Current Transformer Operated Overload Relays, Separate Mount—Frames M–N**[2]
|||||||||||||||||||**For Use**|**Short-Circuit Protection (A)**|**Short-Circuit Protection (A)**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||||||**with**|**Type 1**|**Type 2**||||
|**Overload**|**Contact**||||||||||||||||**Contact**|**Contactor**|**Coordination,**|**Coordination,**|**Circuit**|**CEC/NEC**||
|**Releases, Ir**|**Sequence**||||||||||||||||**Configuration**|**Amp Range**|**gG/gL**|**gG/gL**|**Breaker**|**Fuse**|**Catalog Number**|
|42–63<br>60–90<br>85–125<br>110–160<br>~~— ~~|96<br>98<br>95<br>97<br> ~~HB~~||||||||||||||||1NO-1NC<br>1NO-1NC<br>1NO-1NC<br>1NO-1NC|300–500A<br>300–500A<br>300–500A<br>300–500A|—<br>—<br>—<br>—|—<br>—<br>—<br>—|150<br>250<br>500<br>600|200<br>250<br>400<br>600|**XTOT063C3S**<br>**XTOT090C3S**<br>**XTOT125C3S**<br>**XTOT160C3S**|
|160–240<br>190–290|||||||||||||||||1NO-1NC<br>1NO-1NC|300–500A<br>300–500A|—<br>—|—<br>—|600<br>600|700<br>700|**XTOT240C3S**<br>**XTOT290C3S**|
|270–400|||||||||||||||||1NO-1NC|300–500A|—|—|1000|1000|**XTOT400C3S**|
|360–540|||||||||||||||||1NO-1NC|500A|—|—|600|1000|**XTOT540C3S**|
|420–6303|||||||||||||||||1NO-1NC|630A|—|—|600|1000|**XTOT630C3S**|
## _**Notes**_
1 For separate mounting, short-circuit Type 1 rating is 500A and short-circuit Type 2 rating is 400A.
2 The main current parameters are defined by the main current wiring that is used.
3 Recommend busbar solution at 600A, 1.06 diameter CT openings.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-132**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Accessories**
## **Terminal Lug Kit—Set of Three Lugs**
**XTOBXDIN_ DIN Rail or Panel Mount Adapter, Terminal Lug Kit—Set of Three Lugs Frames C–D**[1] **For Use Pkg. For Use Pkg. Description with… Qty.**[2] **Catalog Number with… Qty.**[2] **Catalog Number** #6 AWG-350 kcmil XTOB…LC1 1 **XTOBXTLL** XTOB…CC1 5 **XTOBXDINC** = ~~e~~ XTOB…DC1 2 **XTOBXDIND** ~~e~~ **Documentation—Manuals for Overload Monitoring of EEX e-motors Terminal Shroud Publication Number For Use with… For Use** MN03402001E XTOB…BC1 **with… Catalog Number** XTOB…CC1 **XTOBXTSL** XTOB…LC1 **XTOBXTSL** MN03407001E XTOB…DC1
|**of EEX e-motors**||
|---|---|
|**Publication Number**|**For Use with…**|
|MN03402001E|XTOB…BC1|
||XTOB…CC1|
|MN03407001E|XTOB…DC1|
||XTOB…GC1|
## _**Notes**_
> 1 Can be snap fitted on a top hat rail (DIN rail) to IEC/EN 60715 or can be screw fitted.
> 2 Orders must be placed in multiples of package quantity listed.
XTOB…HC1 **XTOBXTSCH XTOBXTSCL** XTOB…LC1 to XTCE250L **XTOBXTSCL** or XTCE300L
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-133**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## _**Overload Fitted Directly to the Contactor**_
**1 Frame B (7–15A) Frame C (18–32A)**
**==> picture [65 x 172] intentionally omitted <==**
**==> picture [46 x 120] intentionally omitted <==**
**Frames F–G (80–170A)**
**Frames H–L (185–250A)**
**==> picture [72 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Frame D (40–72A)<br>**----- End of picture text -----**<br>
**==> picture [75 x 177] intentionally omitted <==**
**==> picture [58 x 57] intentionally omitted <==**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-134**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Overload Mounted Separately from the Contactor**_
**Frame C (18–32A) Frame D (40–72A)**
**Frames F–G (80–170A)**
**==> picture [49 x 52] intentionally omitted <==**
**Frames H–L (185–250A)**
**==> picture [70 x 178] intentionally omitted <==**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-135**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Technical Data and Specifications**
## **XTOB Overload Relay—General**
|**XTOB Overload Relay—General**|||||
|---|---|---|---|---|
|**Description**|**XTOB…BC1, XTOB…CC1**|**XTOB…DC1**|**XTOB…GC1, XTOB…GC1S**|**XTOB…HC1, XTOB…LC1**|
|Standards|IEC/EN 60947, VDE 0660,<br>UL, CSA|IEC/EN 60947, VDE 0660,<br>UL, CSA|IEC/EN 60947, VDE 0660,<br>UL, CSA|IEC/EN 60947, VDE 0660,<br>UL, CSA|
|Climate proofing|1|1|1|1|
|Ambient temperature2|–25°C to 55°C|–25°C to 55°C|–25°C to 55°C|–25°C to 50°C|
|Temperature compensation|[–13°F to 131°F]<br>Continuous|[–13°F to 131°F]<br>Continuous|[–13°F to 131°F]<br>Continuous|[–13°F to 122°F]<br>Continuous|
|Mechanical shock resistance (IEC/EN 60068-2-27)<br>half-sinusoidal shock 10 ms|10g|10g|10g|10g|
|Degree of protection|IP20|IP20|IP20|P00|
|Protection against direct contact when actuated|Finger and|Finger and|Finger and|Finger and|
|from front (IEC 536)|back-of-hand proof|back-of-hand proof|back-of-hand proof|back-of-hand proof|
|Insulation voltage (Ui) Vac|690|690|690|1000|
|Overvoltage category/pollution degree|III/3|III/3|III/3|III/3|
|Impulse withstand voltage (Uimp) Vac|6000|6000|6000|8000|
|Operational voltage (Ue) Vac|690|690|690|1000|
|Safe isolation to VDE 0106 Part 101 and part 101/A1<br>between auxiliary contacts and main contacts (Vac)|440|440|440|500|
|between main contacts (Vac)|440|440|440|500|
|Overload release setting range|0.1–32A|6–75A|25–150A|50–300A|
|Short-circuit protection maximum fuse|See overload relay tables starting on**Page V5-T1-144**.||||
|Temperature compensation residual error >40°C|<0.25|<0.25|<0.25|<0.25|
|Current heat loss (three conductors)|||||
|Lower value of setting range, W<br>Upper value of setting range|2.5<br>6|3<br>7.5|16<br>28|16<br>28|
|Terminal capacity|||||
|Solid, mm2|2 x (1–6)|2 x (1–16)|2 x (4–16)|—|
|Flexible with ferrule, mm2|2 x (1–4)|1 x 25|1 x (4–70)|—|
||2 x (1–6)3|2 x (1–10)4|2 x (4–50)|—|
|Flexible with cable lug, mm2|—|—|—|50–240|
|Stranded with cable lug, mm2|—|—|—|50–240|
|Solid or stranded, AWG|14 - 8|14 - 2|3 / 0|250 kcmil|
|Flat conductor (number of segments x width x thickness, mm2)<br>Busbar—width (mm)|—<br>—|—<br>—|—<br>—|6 x 16 x 0.8<br>25|
|Terminal screw|M4|M6|M10|M10 x 35|
|Tightening torque|||||
|Nm|1.8|3.5|10|18|
|Lb-in|16|31|88.5|159.31|
|Tools|||||
|Pozidriv screwdriver|Size 2|Size 2|—|—|
|Standard screwdriver|1 x 6|1 x 6|—|—|
|Hexagon socket head spanner (SW)|—|—|5 mm|16 mm|
## _**Notes**_
> 1 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60068-2-30.
> 2 Ambient temperature operating range to IEC/EN 60947, PTB: –5°C to 50°C.
> 3 6 mm2 flexible with ferrules to DIN 46228.
> 4 Main contact terminal capacity, solid and stranded conductors with ferrules: When using two conductors use identical cross-section.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-136**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTOB Overload Relay—Auxiliary and Control Circuit Connections**
|**Description**||**XTOB…BC1, XTOB…CC1**|**XTOB…DC1**|**XTOB…GC1, XTOB…GC1S**|**XTOB…HC1, XTOB…LC1**|
|---|---|---|---|---|---|
|Impulse withstand voltage (Uimp) Vac||6000|6000|6000|4000|
|Overvoltage category/pollution degree||III/3|III/3|III/3|III/3|
|Terminal capacity||||||
|Solid, mm2<br>Flexible with ferrule, mm2||2 x (0.75–4)<br>2 x (0.75–2.5)|2 x (0.75–4)<br>2 x (0.75–2.5)|2 x (0.75–4)<br>2 x (0.75–2.5)|2 x (0.75–4)<br>2 x (0.75–2.5)|
|Solid or stranded (AWG)||2 x (18–12)|2 x (18–12)|2 x (18–12)|2 x (18–12)|
|Terminal screw||M3.5|M3.5|M3.5|M3.5|
|Tightening torque||||||
|Nm||0.8–1.2|0.8–1.2|0.8–1.2|0.8–1.2|
|Lb-in||7–10.6|7–10.6|7–10.6|7–10.6|
|Tools<br>Pozidriv screwdriver||Size 2|Size 2|Size 2|Size 2|
|Standard screwdriver||1 x 6|1 x 6|1 x 6|1 x 6|
|Rated insulated voltage (Ui) Vac||500|500|500|500|
|Rated operational voltage||500|500|500|500|
|Safe isolation to VDE 0106 Part 101 and<br>between auxiliary contacts|part 101/A1|240|240|240|240|
|Conventional thermal current, Ith||6|6|6|6|
|Rated operational current—AC-15||||||
|Make contact<br>120V||1.5|1.5|1.5|1.5|
|240V||1.5|1.5|1.5|1.5|
|415V||0.5|0.5|0.5|0.5|
|500V||0.5|0.5|0.5|0.5|
|Break contact||||||
|120V||1.5|1.5|1.5|1.5|
|240V||1.5|1.5|1.5|1.5|
|415V||0.9|0.9|0.9|0.9|
|500V||0.8|0.8|0.8|0.8|
|Rated operational current—DC-13 L/R <<br>~~1~~5 ms1||||||
|24V||0.9|0.9|0.9|0.9|
|60V<br>110V||0.75<br>0.4|0.75<br>0.4|0.75<br>0.4|0.75<br>0.4|
|220V||0.2|0.2|0.2|0.2|
|Short-circuit rating without welding maximum fuse, A gG/gl||6|6|6|6|
## _**Note**_
> 1 Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-137**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Tripping Characteristics**_
These tripping characteristics are the mean values of the spread at 20°C ambient temperature in a cold state.
## **XTOB...BC1, XTOB...CC1, XTOB...DC1**
Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approximately
## **XTOB...GC1**
25% of the read off value. Specific characteristics for each individual setting range can be found in MN03402001E.
## **XTOB...HC1, XTOB...LC1**
**==> picture [370 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
2h 2h 2h<br>1 00 XTOB...BC1, 1 00 XTOB...GC1 1 00 XTOB...HC1,XTOB...LC1<br>60 XTOB...CC1, 60 60<br>40 XTOB...DC1 40 40<br>20 20 20<br>10 10 10<br>6 6 6<br>4 4 4<br>2 2 2<br>1 1 1<br>40 40 40<br>3-Phase 3-Phase 3-Phase<br>20 20 20<br>10 10 10<br>6 6 6<br>4 4 4<br>2-Phase 2-Phase 2-Phase<br>2 2 2<br>1 1 1<br>0.6 0.6 0.6<br>1 1.5 2 3 4 6 8 10 15 20 1 1.5 2 3 4 6 8 10 15 20 1 1.5 2 3 4 6 8 10 15 20<br>x Setting Current x Setting Current x Setting Current<br>Minutes Minutes Minutes<br>Seconds Seconds Seconds<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in mm [in]
## **Frames B–C, XTOB…BC1 and XTOB…CC1 Overload Relays**
**==> picture [277 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
35.5<br>[1.40]<br>29.5<br>48<br>39.5 [1.16]<br>[1.89]<br>[1.56]<br>65 [2.56]<br>45 [1.77] 83 [3.27]<br>**----- End of picture text -----**<br>
## **Frame D, XTOB…DC1 Overload Relay**
**==> picture [268 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
20.3 51.5<br>[.80] [2.03]<br>79.2<br>[3.12]<br>95.5 [3.76]<br>60 [2.36] 102 [4.02]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-138**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frame C, XTOBXDINC DIN Rail or Panel Mount Adapter and Frame D, XTOBXDIND DIN Rail or Panel Mount Adapter**
**==> picture [244 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
D1<br>42.5<br>[1.67]<br>H<br>5 [.20] D2<br>1 6.5 [.65] D<br>W<br>H W D D1 D2<br>XTOB…CC1 85 [3.46] 45 [1.77] 90.5 [3.56] 58.3 [2.30] 3.8 [.15]<br>XTOB…DC1 86 [3.39] 60 [2.36] 112 [4.41] 80.5 [3.17] 4.7 [.19]<br>**----- End of picture text -----**<br>
## **Frames F–G, XTOB…GC1 Overload Relay**
## **Frames F–G, XTOB…G1CS Overload Relay**
**==> picture [496 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
99 [3.90] 100 [3.94]<br>80 [3.15] 73 [2.87]<br>121<br>74 [4.76]<br>[2.91]<br>138<br>74 [5.43]<br>[2.91]<br>95 [3.74] 63 [2.48]<br>99 [3.90] 129 [5.08]<br>118 [4.65] 134 [5.28]<br>95 [3.74] 63 [2.48]<br>100 [3.94] 129 [5.08]<br>118 [4.65] 134 [5.28]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-139**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Frames L and H, XTOB…LC1, HC1 Overload Relay**
**==> picture [318 x 212] intentionally omitted <==**
**----- Start of picture text -----**<br>
121 [4.76]<br>110 [4.33]<br>144 [5.67]<br>96 [3.78]<br>111 [4.37]<br>48 [1.89]<br>144<br>[5.67]<br>74 94<br>[2.91] 169 [3.70]<br>7 [.28] [6.65]<br>5 * 7 [.28] Dia.<br>25 [.20] **<br>16.5<br>[.98] [.65] * = OFF<br> ** = RESET/ON<br>128 [5.04] 11 [.43] Dia.<br>*<br>**<br>**----- End of picture text -----**<br>
## **XTOT…C3S Current Transformer Operated Overload Relay**
**==> picture [485 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
185 [7.28]<br>8 [.31] 4.3 [.17] 7.5 [.30] 1 .5 [.06] 185 [7.28]<br>44<br>21 [.83] * M4 [1.73]<br>[2.80] 71 [44 [1.73]] [1.30]33 [2.17]55 [3.35]85 [2.17]55 * 26 [1.02]<br>26 1 59 [6.26]<br>[1.02]<br>172 – 250<br>[6.77 – 9.84]<br>* = RESET/ON<br>200 [7.87]<br>65 65<br>[2.56] [2.56]<br>71<br>[2.80]<br>90° 90° 90°<br>27<br>[1.06]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-140**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**C440/** _**XT**_ **Electronic Overload Relay**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .<br>Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**<br>**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .<br>Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**<br>**V5-T1-128**|
|C440/**_XT_** Electronic Overload Relay<br>Standards and Certifications . . . . . . . . . . . . . .|**V5-T1-142**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-143**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-144**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-146**|
|Technical Data and Specifications . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-149**<br>**V5-T1-155**|
|An Eaton<br>Green Solution<br>wa||
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .<br>Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-157**<br>**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .<br>EMS—Electronic Motor Starter . . . . . . . . . . . . . . .|**V5-T1-217**<br>**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**<br>**V5-T1-234**|
**1**
## **C440/** _**XT**_ **Electronic Overload Relay**
## **Product Description**
Eaton’s new electronic overload relay (EOL) is the most compact, highfeatured, economical product in its class. Designed on a global platform, the new EOL covers the entire power control spectrum including NEMA, IEC and DP contactors. The NEMA and DP versions are offered with the _C440_ designation while the IEC offering has the _**XT**_ designation. The electronic design provides reliable, accurate and value driven protection and communications capabilities in a single compact device. It is the flexible choice for any application requiring easy-touse, reliable protection.
Eaton has a long history of innovations and product development in motor control and protection, including both traditional NEMA, as well as IEC control. It was from this experience that the C440 was developed, delivering new solutions to meet today’s demands.
C440 is a self-powered electronic overload relay available up to 175A as a self contained unit. With external CTs, C440 can protect motor up to 1500 FLA. Available add-on accessories include remote reset capability and communication modules with I/O for DeviceNet, PROFIBUS, and Modbus.
## **Features and Benefits**
## _**Features**_
- Reliable, accurate, electronic motor protection
- Easy to select, install and maintain
- Compact size
- Flexible, intelligent design
- Global product offering—available with NEMA, IEC and DP power control
## **User Interface**
## **Size/Range**
- Broad FLA range (0.33–1500A)
- Large FLA selection dial
- Trip status indicator
- Selectable trip class (10A, 10, 20, 30)
- Operating mode LED
- DIP switch selectable trip class, phase unbalance and ground fault
- Direct mounting to NEMA, IEC and DP contactors
- Most compact electronic overload in its class
- Selectable Auto/Manual reset
## **Motor Control**
## **Feature Options**
- Two B600 alarm (NO) and fault (NC) contacts
- Remote reset
- 120 Vac
- Test/Trip button
- 24 Vac
## **Motor Protection**
- 24 Vdc
- Thermal overload
- Tamper-proof cover
- Phase loss
- Communications modules
- Selectable (ON/OFF) phase unbalance
- Modbus RTU RS-485
- DeviceNet with I/O
- Selectable (ON/OFF) ground fault
- PROFIBUS with I/O
- Modbus RTU with I/O
- Ethernet IP with I/O
- Modbus TCP with I/O
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-141**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Benefits**_
## **Reliability and Improved Uptime**
## **Flexibility**
- C440 provides the users with peace of mind knowing that their assets are protected with the highest level of motor protection and communication capability in its class
- Available with NEMA, IEC and DP contactors
- Improves return on investment by reducing inventory carrying costs with wide FLA adjustment (5:1) and selectable trip class
- Extends the life of plant assets with selectable motor protection features such as trip class, phase unbalance and ground fault
- Design incorporates built-in ground fault protection thus eliminating the need for separate CTs and modules
- Protects against ● Flexible communication unnecessary downtime with optional I/O enables by discovering changes easy integration into plant
- in your system (line/load) management systems for with remote monitoring remote monitoring and
- capabilities control
## **Monitoring Capabilities**
- Individual phase currents RMS
- Average three-phase current RMS
- Thermal memory
- Fault indication (overload, phase loss, phase unbalance, ground fault)
## **Safety**
- IP 20 rated terminal blocks
- Available in Eaton’s industry leading FlashGard MCCs
- Tested to the highest industry standards such as UL, CSA, CE and IEC
- RoHS compliant
## **Standards and Certifications**
- UL
- CSA
- CE
- NEMA
- IEC/EN 60947 VDE 0660
- ISO 13849-1 (EN954-1)
- RoHS
- ATEX directive 94/9/EC
- Equipment Group 2, Category 2
- Status LED provides ● Available as an open added assurance that component and in valuable assets are enclosed control and motor protected by indicating the control center assemblies overload operational status
## **Electronic Overload Education**
|**Description**|**Definition**|**Cause**|**Effect if not Protected**|**C440/****_XT_Protection**|
|---|---|---|---|---|
|**Motor Protection**|||||
|Thermal overload|Overload is a condition in which|• An increase in the load or torque that is|• Increase in current draw leads to heat|• Thermal trip behavior is defined by|
||current draw exceeds 115% of<br>the full load amperage rating for<br>an inductive motor.|being driven by the motor.<br>• A low voltage supply to the motor<br>causes the current to go high to<br>maintain the power needed.|and insulation breakdown, which can<br>cause system failure.<br>• Increase in current can increase<br>power consumption and waste|UL, CSA and IEC standards.<br>• Trip class is settable from 10A,<br>10, 20, 30|
|||• A poor power factor causing above<br>normal current draw.|valuable energy.||
|Ground fault|A line to ground fault.|A current leakage path to ground.|An undetected ground fault can burn<br>through multiple insulation windings,|Fixed protective setting that takes the<br>starter offline if ground fault current|
||||ultimately leading to motor failure, not to|exceeds 50% of the FLA dial setting,|
||||mention risk to equipment or personnel|that is, if the FLA dial is set to 12A, the<br>overload relay will trip if the ground|
|||||current exceeds 6A.|
|Unbalanced phases|Uneven voltage or current between|When a three-phase load is powered with|Unbalanced voltage causes large|Fixed protective setting that takes the|
|(voltage and current)|phases in a three-phase system.|a poor quality line, the voltage per phase|unbalanced currents and as a result this|starter offline if a phase drops below|
|||may be unbalanced.|can lead to motor stator windings being<br>overloaded, causing excessive heating,|50% of the other two phases.|
||||reduced motor efficiency and reduced||
||||insulation life.||
|Phase loss—current|One of the three-phase voltages is|Multiple causes, loose wire, improper|Single-phasing can lead to unwanted|Fixed protective setting that takes the|
|(single-phasing)|not present.|wiring, grounded phase, open fuse, etc.|motor vibrations in addition to the results<br>of unbalanced phases as listed above.|starter offline if a phase is lost.|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-142**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **Electronic Overload Relay—IEC**[1]
## _**XT**_ **OE 1P6 C CS S**
||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||||||
||**Designation**||||||||||||||||**Mounting**||
|**_XT_**=**_XT_**line of IEC control||||||||||||||||**Blank**= Direct to contactor|||
|||||||||||||||||**P**= Pass-through|||
|||**Type**||||||||||||||**S**= Separate mount (Frames C and G only)|||
||**OE**=|Electronic overload||relay|||||||||||||||
||||||||||||||||||**Trip Type**||
||||||||||||||**CS**||= Selectable Class 10A, 10, 20, 30||||
||||||||||||||**GS**||= Ground fault with selectable Class 10, 20||||
||||||||||||||||||||
|||||||**GS**= Groun|
|---|---|---|---|---|---|---|
||||||||
||**Overload Range**||||||
||||||**Contactor Frame**||
|**1P6 **|= 0.33–1.65A|||**B**= 45 mm|||
|**005 **|= 1–5A||||||
|**020**|= 4–20A||||||
|**1P6 **|= 0.33–1.65A|||**C**= 45 mm|||
|**005 **|= 1–5A||||||
|**020**|= 4–20A||||||
|**045**|= 9–45A||||||
|**045 **|= 9–45A|||**D**= 55 mm|||
|**100**|= 20–100A||||||
|**100 **|= 20–100A|||**F, G**=||105 mm|
|**175 **|= 35–175A|||**G,**|**H**= 110 mm||
## _**Note**_
> 1 See **Page V5-T1-144** for Product Selection.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-143**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Product Selection**
## _**XT Electronic Overload Relays**_
|**45 mm****_XT_ for**<br>**Direct Mount**|**_XT_Electronic Overload Relays for Direct Mount to**<br>**For Use with**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to**|**Electronic Overload Relays for Direct Mount to****_XT_Contactors**|**Electronic Overload Relays for Direct Mount to****_XT_Contactors**|**Electronic Overload Relays for Direct Mount to****_XT_Contactors**|**Electronic Overload Relays for Direct Mount to****_XT_Contactors**|**Electronic Overload Relays for Direct Mount to****_XT_Contactors**|**Auxiliary**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||**_XT_ Contactor**|**For Use with**|**Overload**|**Contact**||||||**Contact**|||||**Frame**|**Contact**|||
||**Frame**|**Contactor**|**Range (Amps)**|**Sequence**|||||||||||**Size**|**Configuration**|**Type**|**Catalog Number**|
||B|XTCE007B…,|0.33–1.65||||||||97 95||||45 mm|NO-NC|ZEB12-1,65|**XTOE1P6BCS**|
|||XTCE009B…,<br>XTCE012B…,<br>XTCE015B…|1–5<br>4–20||2||4||6 98 96||6 98 96||||||ZEB12-5<br>ZEB12-20|**XTOE005BCS**<br>**XTOE020BCS**|
||C|XTCE018C…,|0.33–1.65||||||||97 95||||45 mm|NO-NC|ZEB32-1,65|**XTOE1P6CCS**|
|||XTCE025C…,<br>XTCE032C|1–5<br>~~—~~||||||||||||||ZEB32-5<br>**XTOE005CCS**<br>~~oe~~||
||||4–20<br>9–45||2||4||6 98 96||6 98 96||||||ZEB32-20<br>ZEB32-45|**XTOE020CCS**<br>**XTOE045CCS**|
||D|XTCE040D…,<br>XTCE050D…,<br>XTCE065D…,<br>XTCE072D…|9–45<br>20–100||2 4 6 98 96<br>97 95<br>~~deh4~~||||||||||45 mm<br>55 mm|NO-NC|ZEB65-45<br>ZEB65-100|**XTOE045DCS**<br>**XTOE100DCS**|
||F|XTCE080F…,<br>XTCE095F…|20–100||2 4 6 98 96<br>97 95<br>~~ca~~||||||||||55 mm|NO-NC|ZEB150-100|**XTOE100GCS**|
||G<br>XTCE115G…,<br>XTCE150G…,<br>XTCE170G…<br>20–100<br>35–175<br>H<br>XTCE185H…<br>35–175<br>2 4 6 98 96<br>97 95<br>~~ep~~||||||||||||||55 mm<br>110 mm<br>110 mm|NO-NC<br>NO-NC|ZEB150-100<br>ZEB150-175<br>ZEB225-175|**XTOE100GCS**<br>**XTOE175GCS**<br>**XTOE175HCS**|
|**45 mm****_XT_ for**<br>**Direct Mount**<br>**with Ground Fault**|**_XT_Electronic Overload Relays with Ground Fault for Direct Mount to**<br>**For Use with**<br>**_XT_ Contactor**|**Electronic Overload Relays with Ground Fault for Direct Mount to**<br>**For Use with**|**Electronic Overload Relays with Ground Fault for Direct Mount to****_XT_Contactors**<br>**Overload**<br>**Contact**<br>**Frame**<br>**Auxiliary**<br>**Contact**|
|---|---|---|---|
|**Frame**<br>**Contactor**<br>**Range (Amps)**<br>**Sequence**<br>**Size**<br>**Configuration**<br>**Type**<br>**Catalog Number**<br>B<br>XTCE007B…,<br>XTCE009B…,<br>XTCE012B…,<br>XTCE015B…<br>0.33–1.65<br>45 mm<br>NO-NC<br>ZEB12-1,65-GF<br>**XTOE1P6BGS**<br>1–5<br>ZEB12-5-GF<br>**XTOE005BGS**<br>4–20<br>ZEB12-20-GF<br>**XTOE020BGS**<br>C<br>XTCE018C…,<br>XTCE025C…,<br>XTCE032C<br>0.33–1.65<br>45 mm<br>NO-NC<br>ZEB32-1,65-GF<br>**XTOE1P6CGS**<br>1–5<br>ZEB32-5-GF<br>**XTOE005CGS**<br>2 4 6 98 96<br>97 95<br>97 95<br>s~~ay~~<br>~~EEE~~<br>~~—~~<br>~~a~~||||
||||4–20<br>ZEB32-20-GF<br>**XTOE020CGS**<br>9–45<br>ZEB32-45-GF<br>**XTOE045CGS**<br>2 4 6 98 96|
||D|XTCE040D…,<br>XTCE050D…,<br>XTCE065D…,<br>XTCE072D…|9–45<br>45 mm<br>NO-NC<br>ZEB65-45-GF<br>**XTOE045DGS**<br>20–100<br>55 mm<br>ZEB65-100-GF<br>**XTOE100DGS**<br>2 4 6 98 96<br>97 95<br>~~a~~|
||F|XTCE080F…,<br>XTCE095F…|20–100<br>55 mm<br>NO-NC<br>ZEB150-100-GF<br>**XTOE100GGS**<br>2 4 6 98 96<br>97 95<br>~~sh~~|
||G<br>XTCE115G…,<br>XTCE150G…,<br>XTCE170G…<br>20–100<br>55 mm<br>NO-NC<br>ZEB150-100-GF<br>**XTOE100GGS**<br>35–175<br>110 mm<br>ZEB150-175-GF<br>**XTOE175GGS**<br>97 95<br>~~ep~~|||
||H|XTCE185H…|35–175<br>110 mm<br>NO-NC<br>ZEB225-175-GF<br>**XTOE175HGS**<br>2 4 6 98 96|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-144**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **1–5A OL with CTs**
_**XT**_ **Electronic Overload Relays for use with Large Frame** _**XT**_ **Contactors (L–R)** Use CTs and 1-5A _**XT**_ overload relay. CT kit does not include overload relay (order separately).
|Use CTs and 1-5A|Use CTs and 1-5A**_XT_** overload relay. CT kit does not include overload relay (order separately).|overload relay. CT kit does not include overload relay (order separately).|overload relay. CT kit does not include overload relay (order separately).|overload relay. CT kit does not include overload relay (order separately).|overload relay. CT kit does not include overload relay (order separately).|overload relay. CT kit does not include overload relay (order separately).||
|---|---|---|---|---|---|---|---|
|**_XT_**<br>**Contactor**|**For Use with IEC**<br>**Contactor Amp**|**CT Range**||**CT Kit**|**Terminal**|**Overload Relay**|**Overload Relay**<br>**with Ground Fault**|
|**Frame**|**Range (AC-3)**|**(Amps)**|**Description**|**Catalog Number**|**Size**|**Catalog Number**|**Catalog Number**|
|L, M|185–500A|60-300|300: 5 panel-mount CT kit|**ZEB-XCT300**|750 kcmil|**XTOE005CCSS**|**XTOE005CGSS**|
||||with integrated lugs||(2) 250 kcmil|||
||||||3/0 Cu/Al|||
|M, N|300–820A|120-600|600: 5 panel-mount CT kit|**ZEB-XCT600**|(2) 750 kcmil|**XTOE005CCSS**|**XTOE005CGSS**|
||||with integrated,<br>pass through holes||3/0 Cu/Al|||
|N|580–1000A|200-1000|1000: 5 panel-mount CT kit<br>with integrated,|**ZEB-XCT1000**|(3) 750 kcmil<br>3/0 Cu/Al|**XTOE005CCSS**|**XTOE005CGSS**|
||||pass through holes|||||
|R|1600A|300-1500|1500: 5 panel-mount CT kit|**ZEB-XCT1500**|(4) 750 kcmil|**XTOE005CCSS**|**XTOE005CGSS**|
||||with integrated,||1/0 Cu/Al|||
||||pass through holes|||||
**45 mm** _**XT**_ **for** _**XT**_ **Electronic Overload Relays for Separate Mount Separate Mount**
|**45 mm****_XT_ for**<br>**Separate Mount**|**_XT_Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**|**Electronic Overload Relays for Separate Mount**||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Separate Mount**|**Overload**|**Frame**|**Contact**||||||**Contact**||||**Overload Relay**|**Overload Relay**<br>**with Ground Fault**|
|SS|**Range (Amps)**<br>**Overload Relay**<br>0.33–1.65<br>1–5<br>4–20<br> ~~—~~|**Size**<br>45 mm|**Sequence**<br>1 3 5 97 95<br>2 4 6 98 96|||||||||**Type**<br>ZEB32-1,65/KK<br>ZEB32-5/KK<br>ZEB32-20/KK|**Catalog Number**<br>**XTOE1P6CCSS**<br>**XTOE005CCSS**<br>**XTOE020CCSS**|**Catalog Number**<br>**XTOE1P6CGSS**<br>**XTOE005CGSS**<br>**XTOE020CGSS**|
||9–45<br>20–100|55 mm||||||||||ZEB32-45/KK<br>ZEB150-100/KK|**XTOE045CCSS**<br>**XTOE100GCSS**|**XTOE045CGSS**<br>**XTOE100GGSS**|
||35–175|110 mm||||||||||ZEB150-175/KK|**XTOE175GCSS**|**XTOE175GGSS**|
_**XT**_ **Electronic Overload Relay for Pass-Through Design** Pass-through design does not include any lugs to land wires. Terminate motor leads directly on contactor.
|**Overload**|**Frame**|**Contact**|**Contact**||||**Overload Relay**|**Overload Relay**<br>**with Ground Fault**|
|---|---|---|---|---|---|---|---|---|
|**Range (Amps)**<br>35–175|**Size**<br>110 mm|**Sequence**<br>1 3 5 97 95||||**Type**<br>ZEB150-175/PT|**Catalog Number**<br>**XTOE175GCSP**|**Catalog Number**<br>**XTOE175GGSP**|
|||2 4 6 98 96<br>~~eng~~|||||||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-145**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Accessories**
**==> picture [25 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
CT Kits<br>**----- End of picture text -----**<br>
**==> picture [349 x 230] intentionally omitted <==**
**----- Start of picture text -----**<br>
Accessories<br>Description Catalog Number<br>De oo EE EEE<br>Safety Cover Safety Cover<br>Clear Lexan cover that mounts on top of the FLA dial and DIP switches when closed. ZEB-XSC<br>he Yel a<br>|<br>» *—<br>me —_ >, hy<br>Reset Bar Reset Bar<br>Assembles to the top of the overload to provide a larger target area for door ZEB-XRB<br>f ~ mounted reset operators.<br>SS F. ey<br>—_ ae bs 2 / ay<br>"= —4<br>L<br>Remote Reset Remote Reset<br>Remote reset module (24 Vdc) [1] C440-XCOM<br>Remote reset module (120 Vac) [1] ZEB-XRR-120<br>Remote reset module (24 Vac) [1] ZEB-XRR-24<br>**----- End of picture text -----**<br>
## _**Communication**_
The C440 is provided with two levels of communication capability.
## **Basic Communication via Expansion Module— Monitoring Only**
Basic communication on the C440 is accomplished using an expansion module. The expansion module plugs into the expansion bay on the C440 overload relay, enabling communications with the overload via their Modbus RTU (RS-485) network. No additional parts are required. See figure below.
## **Advanced Communication— Monitoring and Control**
C440 also has the ability to communicate on industrial protocols such as DeviceNet, PROFIBUS, Modbus RTU and Modbus TCP, and Ethernet (planned) while providing control capability using I/O.
An expansion module (mentioned earlier) combined with a communication adapter and a communication module allows easy integration onto the customer’s network. See figure below.
## **Advanced Communication— Communication Module**
The communication adapter comes standard with four inputs and two outputs (24 Vdc or 120 Vac) while providing the customer with flexible mounting options (DIN rail or panel). See figure below,
**==> picture [70 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
Basic Communication—<br>Modbus<br>**----- End of picture text -----**<br>
**==> picture [85 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Advanced Communication—<br>Communication Adapter with<br>Communication Module<br>**----- End of picture text -----**<br>
**==> picture [14 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note<br>**----- End of picture text -----**<br>
> 1 Customer can wire remote mounted button to reset module (that is, 22 mm pushbutton, catalog number M22-D-B-GB14-K10).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-146**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
The following information can be viewed using the communication option:
- Motor status—running, ● Percent thermal capacity ● Overload relay settings— stopped, tripped or ● Fault codes (only available trip class, DIP switch resetting prior to reset) selections, reset selections
- Individual rms phase currents (A, B, C)
- Individual rms phase ● Percent phase unbalance ● Modbus address (can be currents (A, B, C) ● Ground fault current and set over the network)
- ● Average of three-phase percent rms current
**1**
## **Communication Accessories**
**Description Catalog Number Expansion Module** Expansion module (Remote Reset/Modbus RTU, RS-485 Communication) **C440-XCOM Communication** Communication adapter kit (DIN C Panel mounted adapter, required for advance communication option) **C440-COM-ADP Adapter** $ DeviceNet communication module kit—120V I/O (consists of C440-XCOM + C441K + C440-COM-ADP) **C440-DN-120** DeviceNet communication module kit—24 Vdc I/O (consists of C440-XCOM + C441L + C440-COM-ADP) **C440-DN-24** PROFIBUS communication module kit—120V I/O (consists of C440-XCOM + C441S + C440-COM-ADP) **C440-DP-120** PROFIBUS communication module kit—24V I/O (consists of C440-XCOM + C441Q + C440-COM-ADP) **C440-DP-24** Modbus communication module kit—120V I/O (consists of C440-XCOM + C441N + C440-COM-ADP) **C440-MOD-120** Modbus communication module kit—24 Vdc I/O (consists of C440-XCOM + C441P + C440-COM-ADP) **C440-MOD-24** Modbus TCP/Ethernet IP communication module kit—120V I/O (consists of C440-XCOM + C441U) **C440-ET-120** Modbus TCP/Ethernet IP communication module kit—24V I/O (consists of C440-XCOM + C441V) **C440-ET-24**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-147**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Modbus Communication Module**_
The Modbus module combined with an expansion module and a communication adapter provide Modbus communication capability to the C440 electronic overload relay.
**Modbus Communication Module**
## **Features and Benefits**
- The Modbus
- communication module is capable of baud rates up to 115K
- The Modbus address and baud rate configuration can be easily changed using the HMi user interface
- Modbus address and baud rate are set via convenient DIP switches; LEDs are provided to display Modbus traffic
- Configuration with common Modbus configuration tools
- Terminals
- Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed
- Each terminal is marked for ease of wiring and troubleshooting
- Selectable I/O assemblies
- 4IN/2OUT
- Signal types include 24 Vdc I/O and 120 Vac I/O
- Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops
- Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise
- Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF
## _**DeviceNet Communication Modules**_
The DeviceNet Communication Module provides monitoring and control for the C440 overload relay from a single DeviceNet node. These modules also offer convenient I/O in two voltage options, 24 Vdc and 120 Vac.
**DeviceNet Communication Module**
## **Features and Benefits**
- Communication to DeviceNet uses only one DeviceNet MAC ID
- Terminals
- Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed
- Configuration
- DeviceNet MAC ID and Baud rate are set via field wiring installed convenient DIP switches ● Each terminal is marked with an option to set for ease of wiring and from the network troubleshooting
- Advanced configuration available using common DeviceNet tools
- Selectable I/O assemblies
- 4IN/2OUT
- Signal types include 24 Vdc I/O and 120 Vac I/O
- Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops
- Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise
- Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF
- Combined status LED
## _**PROFIBUS Communication Modules**_
The PROFIBUS module combined with an expansion module and a communication adapter provide Modbus communication capability to the C440 electronic overload relay.
**PROFIBUS Communication Module**
## **Features and Benefits**
- The PROFIBUS
communication module is capable of baud rates up to 12 Mb
- PROFIBUS address is set via convenient DIP switches; LEDs are provided to display PROFIBUS status
- Intuitive configuration with common PROFIBUS configuration tools
- Terminals
- Unique locking mechanism provides for easy removal of the terminal block with the field wiring installed
- Each terminal is marked for ease of wiring and troubleshooting
- Selectable I/O assemblies
- 4IN/2OUT
- Signal types include 24 Vdc I/O and 120 Vac I/O
- Each I/O module is optically isolated between the field I/O and the network adapter to protect the I/O and communication circuits from possible damage due to transients and ground loops
- Input Module features a user-definable input debounce, which limits the effects of transients and electrical noise
- Output Module supports a user-definable safe state for loss of communication; hold last state, ON or OFF
**V5-T1-148 Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Technical Data and Specifications**
**Electronic Overload Relays up to 1500A**
||**Specification**|||
|---|---|---|---|
|**Description**|**45 mm**|**55 mm**|**110 mm**|
|**Electrical Ratings**|**Range**|**Range**|**Range**|
|Operating voltage (three-phase) and frequency<br>**FLA Range**|690 Vac (60/50 Hz)|690 Vac (60/50 Hz)|690 Vac (60/50 Hz)|
||0.33–1.65A<br>1–5A|20–100A|28–140A (NEMA)<br>35–175A (IEC)|
||4–20A|||
||9–45A|||
|**Use with Contactors**||||
|**_XT_**IEC frames|B, C, D|F, G|G, H|
|Freedom NEMA sizes<br>**Trip Class**|00, 0, 1, 2|3|4|
||10A, 10, 20, 30<br>Selectable|10A, 10, 20, 30<br>Selectable|10A, 10, 20, 30<br>Selectable|
|**Motor Protection**||||
|Thermal overload setting|1.05 x FLA: does not trip|1.05 x FLA: does not trip|1.05 x FLA: does not trip|
||1.15 x FLA: overload trip|1.15 x FLA: overload trip|1.15 x FLA: overload trip|
|**Feature**|**Range**|**Range**|**Range**|
|Phase loss|Fixed threshold 50%|Fixed threshold 50%|Fixed threshold 50%|
|Phase unbalance (selectable: enable/disable)|Fixed threshold 50%|Fixed threshold 50%|Fixed threshold 50%|
|Ground fault (selectable: enable/disable)|50% of FLA dial setting|50% of FLA dial setting|50% of FLA dial setting|
||>150% = 2 sec|>150% = 2 sec|>150% = 2 sec|
||>250% = 1 sec|>250% = 1 sec|>250% = 1 sec|
|Reset|Manual/automatic|Manual/automatic|Manual/automatic|
|**Indicators**||||
|Trip status<br>Mode LED|Orange flag<br>One flash: Overload operating properly|Orange flag<br>One flash: Overload operating properly|Orange flag<br>One flash: Overload operating properly|
||Two flashes: Current is above FLA dial|Two flashes: Current is above FLA dial|Two flashes: Current is above FLA dial|
||setting—pending trip|setting—pending trip|setting—pending trip|
|**Options**||||
|Remote reset|Yes|Yes|Yes|
|Reset bar<br>Communication expansion module|Yes<br>Yes|Yes<br>Yes|Yes<br>Yes|
|Communication adapter|Yes|Yes|Yes|
|**Capacity**||||
|Load terminals||||
|Terminal capacity|12–10 AWG (4–6 mm2)|6–1 AWG (16–50 mm2)|8–4/0 AWG (10–95 mm2)|
||8–6 AWG (6–16 mm2)|||
|Tightening torque|20–25 lb-in (2.3–2.8 Nm)|25–30 lb-in (2.8–3.4 Nm)|124 lb-in (14 Nm)|
||25–30 lb-in (2.8–3.4 Nm)|||
|Input, auxiliary contact and remote reset terminals||||
|Terminal capacity|2 x (18–12) AWG|2 x (18–12) AWG|2 x (18–12) AWG|
|Tightening torque<br>**Voltages**|7–11 lb-in (0.8–1.2 Nm)|7–11 lb-in (0.8–1.2 Nm)|7–11 lb-in (0.8–1.2 Nm)|
|Insulation voltage Ui(three-phase)|690 Vac|690 Vac|690 Vac|
|Insulation voltage Ui(control)|500 Vac|500 Vac|500 Vac|
|Rated impulse withstand voltage|6000 Vac|6000 Vac|6000 Vac|
|Overvoltage category/pollution degree|III/3|III/3|III/3|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-149**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Electronic Overload Relays up to 1500A, continued**
||**Specification**|||
|---|---|---|---|
|**Description**|**45 mm**|**55 mm**|**110 mm**|
|**Auxiliary and Control Circuit Ratings**||||
|Conventional thermal continuous current|5A|5A|5A|
|Rated operational current—IEC AC-15||||
|Make contact (1800 VA)||||
|120V<br>240V|15A<br>15A|15A<br>15A|15A<br>15A|
|415V|0.5A|0.5A|0.5A|
|500V|0.5A|0.5A|0.5A|
|Break contact (180 VA)||||
|120V|1.5A|1.5A|1.5A|
|240V|1.5A|1.5A|1.5A|
|415V|0.9A|0.9A|0.9A|
|500V|0.8A|0.8A|0.8A|
|IEC DC-13 (L/R F 15 ms1)||||
|0–250V|1.0A|1.0A|1.0A|
|Rated operational current—UL B600||||
|Make contact (3600 VA)<br>120V|30A|30A|30A|
|240V|15A|15A|15A|
|480V|7.5A|7.5A|7.5A|
|600V|6A|6A|6A|
|Break contact (360 VA)||||
|120V|3A|3A|3A|
|240V<br>480V|1.5A<br>0.75A|1.5A<br>0.75A|1.5A<br>0.75A|
|600V|0.6A|0.6A|0.6A|
|R300—Vdc ratings (28 VA)||||
|0–120V|0.22A|0.22A|0.22A|
|250V|0.11A|0.11A|0.11A|
|**Short-Circuit Rating without Welding**||||
|Maximum fuse|6A gG/gL|6A gG/gL|6A gG/gL|
|**Environmental Ratings**||||
|Ambient temperature (operating)|–13° to 149°F (–25° to 65°C)|–13° to 149°F (–25° to 65°C)|–13° to 149°F (–25° to 65°C)|
|Ambient temperature (storage)|–40° to 185°F (–40° to 85°C)|–40° to 185°F (–40° to 85°C)|–40° to 185°F (–40° to 85°C)|
|Operating humidity UL 991 (H3)|5% to 95% non-condensing|5% to 95% non-condensing|5% to 95% non-condensing|
|Altitude (no derating) NEMA ICS1<br>Shock (IEC 600068-2-27)|2000m<br>15g any direction|2000m<br>15g any direction|2000m<br>15g any direction|
|Vibration (IEC 60068-2-6)|3g any direction|3g any direction|3g any direction|
|Pollution degree per IEC 60947-4-1|3 for product (2 for pcb)|3 for product (2 for pcb)|3 for product (2 for pcb)|
|Ingress protection|IP20|IP20|IP20|
|Protection against direct contact when actuated from|Finger- and back-of-hand proof|Finger- and back-of-hand proof|Finger- and back-of-hand proof|
|front (IEC 536)||||
|Mounting position|Any|Any|Any|
|Climatic proofing|Damp heat, constant to IEC 60068-2-30|Damp heat, constant to IEC 60068-2-30|Damp heat, constant to IEC 60068-2-30|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-150**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **Electronic Overload Relays up to 1500A, continued**
|**Description**|**Specification**<br>**45 mm**<br>**55 mm**<br>**110 mm**|
|---|---|
|**Electrical/EMC**||
|Radiated emissions<br>IEC 60947-4-1-Table 15<br>EN 55011 (CISPIR 11) Group 1, Class A, ISM|30 mHz to 1000 mHz<br>30 mHz to 1000 mHz<br>30 mHz to 1000 mHz|
|Conducted emissions<br>IEC 60947-4-1-Table 14<br>EN 55011 (CISPIR 11) Group 1; Class ISM|0.15 mHz to 30 mHz<br>0.15 mHz to 30 mHz<br>0.15 mHz to 30 mHz|
|ESD immunity<br>IEC 60947-4-1 (Table 13)|±8 kV air, ±6 kV contact<br>±8 kV air, ±6 kV contact<br>±8 kV air, ±6 kV contact|
|Radiated immunity<br>IEC 60947-4-1<br>IEC 61000-4-3|10 V/m 80 mHz–1000 mHz<br>3 V/m from 1.4 to 2.7 gHz<br>80% amplitude modulated<br>1 kHz sine wave<br>10 V/m 80 mHz–1000 mHz<br>3 V/m from 1.4 to 2.7 gHz<br>80% amplitude modulated<br>1 kHz sine wave<br>10 V/m 80 mHz–1000 mHz<br>3 V/m from 1.4 to 2.7 gHz<br>80% amplitude modulated<br>1 kHz sine wave|
|Conducted immunity<br>IEC 60947-4-1, IEC 61000-4-6|140 dub (10V rms)<br>150 kHz–100 mHz<br>140 dub (10V rms)<br>150 kHz–100 mHz<br>140 dub (10V rms)<br>150 kHz–100 mHz|
|Fast transient immunity<br>IEC 60947-4-1 (Table 13)<br>IEC 61000-4-4|±4 kV using direct method<br>with accessory installed in expansion bay<br>±2 kV using direct method<br>±4 kV using direct method<br>with accessory installed in expansion bay<br>±2 kV using direct method<br>±4 kV using direct method<br>with accessory installed in expansion bay<br>±2 kV using direct method|
|Surge immunity<br>IEC 60947-4-1 (Table 13)<br>IEC 61000-4-5 a Class 4|Three-phase power inputs:<br>±4 kV line-to-line (DM)<br>±4 kV line-to-ground (CM)<br>Three-phase power inputs:<br>±4 kV line-to-line (DM)<br>±4 kV line-to-ground (CM)<br>Three-phase power inputs:<br>±4 kV line-to-line (DM)<br>±4 kV line-to-ground (CM)|
||With accessory installed in expansion bay:<br>±2 kV line-to-line (DM) –>1.2/50 us;<br>2 kV line-to-earth, 1 kV line-to-line<br>±4 kV line-to-ground (CM)<br>With accessory installed in expansion bay:<br>±2 kV line-to-line (DM) –>1.2/50 us;<br>2 kV line-to-earth, 1 kV line-to-line<br>±4 kV line-to-ground (CM)<br>With accessory installed in expansion bay:<br>±2 kV line-to-line (DM) –>1.2/50 us;<br>2 kV line-to-earth, 1 kV line-to-line<br>±4 kV line-to-ground (CM)|
|Power freq. magnetic field immunity<br>IEC 60947-4-1, IEC 61000-4-8|30 A/m, 50 Hz<br>30 A/m, 50 Hz<br>30 A/m, 50 Hz|
|Electromagnetic field<br>IEC 60947-4-1 Table 13, IEC 61000-4-3|10 V/m<br>10 V/m<br>10 V/m|
|Distortion IEEE 519|5% THD max., 5th harmonic 3% max.<br>5% THD max., 5th harmonic 3% max.<br>5% THD max., 5th harmonic 3% max.|
|Electrostatic discharge (ESD)<br>IEC 61000-4-2, EN 61131-2|4 kV contact<br>8 kV air discharge<br>4 kV contact<br>8 kV air discharge<br>4 kV contact<br>8 kV air discharge|
|Electrical fast transient (EFT)<br>IEC 61000-4-4, EN 61131-2|±2 kV using direct method<br>±2 kV using direct method<br>±2 kV using direct method|
|Surge immunity<br>IEC 61000-4-5, EN 61131-2|±2 kV line-to-ground (CM)<br>±2 kV line-to-ground (CM)<br>±2 kV line-to-ground (CM)|
**1**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-151**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **Communication Modules**
|**1**|**Communication Modules**<br>**Description**|**Modbus**|**DeviceNet**|**PROFIBUS**|**Ethernet**|
|---|---|---|---|---|---|
|**1**|**Electrical/EMC**|||||
||Radiated emissions|30–1000 mHz|30–1000 mHz|30–1000 mHz|30–1000 mHz|
|**1**|IEC 60947-4-1—Table 15, EN 55011<br>(CISPIR 11) Group 1, Class A|||||
|**1**|Conducted emissions<br>IEC 60947-4-1—Table 14, EN 55011|0.15–30 mHz|0.15–30 mHz|0.15–30 mHz|0.15–30 mHz|
||(CISPIR 11) Group 1, Class A|||||
|**1**|ESD immunity|±8 kV air, ±4 kV contact|±8 kV air, ±4 kV contact|±8 kV air, ±4 kV contact|±8 kV air, ±4 kV contact|
||IEC 60947-4-1 (Table 13)|||||
|**1**|Radiated immunity|10 V/m 80–1000 mHz|10 V/m 80–1000 mHz|10 V/m 80–1000 mHz|10 V/m 80–1000 mHz|
||IEC 60947-4-1|80% amplitude modulated|80% amplitude modulated|80% amplitude modulated|80% amplitude modulated|
|**1**|Conducted immunity|1 kHz sine wave<br>140 dBuV (10V rms)|1 kHz sine wave<br>140 dBuV (10V rms)|1 kHz sine wave<br>140 dBuV (10V rms)|1 kHz sine wave<br>140 dBuV (10V rms)|
|**1**|IEC 60947-4-1<br>Fast transient immunity|150 kHz–80 mHz<br>±2 kV using direct method|150 kHz–80 mHz<br>±2 kV supply and control,|150 kHz–80 mHz<br>±2 kV supply and control,|150 kHz–80 mHz<br>±2 kV supply and control,|
|**1**|IEC 60947-4-1 (Table 13) IEC 6100-4-4<br>Surge immunity|User IO and communication lines1:|±1 kV communication<br>User IO and communication lines:|±1 kV communication<br>User IO and communication lines:|±1 kV communication<br>User IO and communication lines:|
||IEC 60947-4-1 (Table 13)|±1 kV line-to-line (DM)|±0.5 kV line-to-line (DM)|±0.5 kV line-to-line (DM)|±0.5 kV line-to-line (DM)|
|**1**|IEC 61000-4-5 Class 3|±2 kV line-to-ground (CM)|±1 kV line-to-ground (CM)|±1 kV line-to-ground (CM)|±1 kV line-to-ground (CM)|
||Electromagnetic field1|10 V/m|10 V/m|10 V/m|10 V/m|
|**1**|IEC 60947-4-1 (Table 13) IEC 61000-4-3|||||
||**Environmental Ratings**|||||
|**1**|Ambient temperature (operating)|–4° to 122°F (–20° to 50°C)|–13° to 122°F (–25° to 50°C)|–13° to 122°F (–25° to 50°C)|–13° to 122°F (–25° to 50°C)|
||Ambient temperature (storage)|–40° to 185°F (–40° to 85°C)|–40° to 185°F (–40° to 85°C)|–40° to 185°F (–40° to 85°C)|–40° to 185°F (–40° to 85°C)|
|**1**|Operating humidity|5–95% noncondensing|5–95% noncondensing|5–95% noncondensing|5–95% noncondensing|
|**1**|Altitude (no derating)<br>Shock (IEC 600068-2-27)|2000m<br>15G any direction|2000m<br>15G any direction|2000m<br>15G any direction|2000m<br>15G any direction|
|**1**|Vibration (IEC 60068-2-6)|3G any direction|3G any direction|3G any direction|3G any direction|
||Pollution degree per IEC 60947-1|3|3|3|3|
|**1**|Degree of protection|IP20|IP20|IP20|IP20|
||Overvoltage category per UL 508|III|III|III|III|
|**1**|**DeviceNet**|||||
|**1**|DeviceNet connections|—|Group 2, polling, bit strobe,<br>explicit, no UCMM|—|Group 2, polling, bit strobe,<br>explicit, no UCMM|
||DeviceNet baud rate|—|125K, 250K, 500K|—|125K, 250K, 500K|
|**1**|**Ethernet**|||||
|**1**|Ethernet connections|—|—|—|Integrated two-port switch with dual<br>RJ45 Ethernet connections|
|**1**|Ethernet type|—|—|—|Ethernet 10/100 Mbs, AutoMDX,<br>Auto Negotiation|
||**PROFIBUS**|||||
|**1**|PROFIBUS connections|—|—|Group 2, polling, bit strobe,|—|
|||||explicit, no UCMM||
|**1**|PROFIBUS baud rate|—|—|9.6K, 19.2K, 45.45K, 93.75K, 187.5K,|—|
|||||500K, 1.5M, 3M, 6M, 12M||
## _**Note**_
> 1 Relates to C441M only.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-152**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Communication Modules, continued**
|**Description**|**Modbus**|**DeviceNet**|**PROFIBUS**|**Ethernet**|
|---|---|---|---|---|
|**C441_ 24 Vdc Input**|||||
|Nominal input voltage|24 Vdc|24 Vdc|24 Vdc|24 Vdc|
|Operating voltage|18–30 Vdc|18–30 Vdc|18–30 Vdc|18–30 Vdc|
|Number of inputs|4|4|4|4|
|Signal delay|5 ms (programmable to 65 sec)|5 ms (programmable to 65 sec)|5 ms (programmable to 65 sec)|5 ms (programmable to 65 sec)|
|OFF-state voltage<br>ON-state voltage|<6 Vdc<br>>18 Vdc|<6 Vdc<br>>18 Vdc|<6 Vdc<br>>10 Vdc|<6 Vdc<br>>18 Vdc|
|Nominal input current<br>Isolation|5 mA<br>1500V|5 mA<br>1500V|5 mA<br>1500V|5 mA<br>1500V|
|Terminal screw torque|7–9 in-lb|7–9 in-lb|7–9 in-lb|7–9 in-lb|
|24V source current|50 mA|50 mA|50 mA|50 mA|
|**Operating Voltage Range—DC**|**Input Modules**||||
|OFF state|0–6 Vdc|0–6 Vdc|0–6 Vdc|0–6 Vdc|
|Transition region|6–18 Vdc|6–18 Vdc|6–18 Vdc|6–18 Vdc|
|ON state|18–30 Vdc|18–30 Vdc|18–30 Vdc|18–30 Vdc|
|**C441_ 120 Vac Input**|||||
|Nominal input voltage<br>Operating voltage|120 Vac<br>80–140 Vac|120 Vac<br>80–140 Vac|120 Vac<br>80–140 Vac|120 Vac<br>80–140 Vac|
|Number of inputs|4|4|4|4|
|OFF-state voltage|<30 Vac|<30 Vac|<20 Vac|<30 Vac|
|ON-state voltage|>80 Vac|>80 Vac|>70 Vac|>80 Vac|
|Nominal input current|15 mA|15 mA|15 mA|15 mA|
|Signal delay|1/2 cycle|1/2 cycle|1/2 cycle|1/2 cycle|
|Isolation|1500V|1500V|1500V|1500V|
|Terminal screw torque|7–9 in-lb|7–9 in-lb|7–9 in-lb|7–9 in-lb|
|**Operating Voltage Range—AC**<br>OFF state|**Input Modules**<br>0–30 Vac|0–30 Vac|0–30 Vac|0–30 Vac|
|Transition region<br>ON state|30–80 Vac<br>80–140 Vac|30–80 Vac<br>80–140 Vac|30–80 Vac<br>80–140 Vac|30–80 Vac<br>80–140 Vac|
|**Output Modules**|||||
|Nominal voltage|120 Vac|120 Vac|120 Vac|120 Vac|
|Number of outputs|24 Vdc<br>(2) 1NO Form A|24 Vdc<br>(2) 1NO Form A|24 Vdc<br>(2) 1NO Form A|24 Vdc<br>(2) 1NO Form A|
|Relay OFF time|1NO/NC Form C<br>3 ms|1NO/NC Form C<br>3 ms|1NO/NC Form C<br>3 ms|1NO/NC Form C<br>3 ms|
|Relay ON time<br>Max. current per point1|7 ms<br>5A (B300 rated)|7 ms<br>5A (B300 rated)|7 ms<br>5A (B300 rated)|7 ms<br>5A (B300 rated)|
|Electrical life|100,000 cycles|100,000 cycles|100,000 cycles|100,000 cycles|
|Mechanical life|1,000,000 cycles|1,000,000 cycles|1,000,000 cycles|1,000,000 cycles|
## _**Note**_
> 1 Relates to C441M only.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-153**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## _**Short Circuit Ratings (North America CSA, cUL)**_
Changes to UL 508A and NEC in recent years have brought a focus to control panel safety with regard to short-circuit current ratings (SCCR). Eaton’s C440 electronic overload relays combined with _**XT**_ series IEC and Freedom Series NEMA contactors provide a wide variety of SCCR solutions needed for a variety of applications. The SCCR data in this document reflects the latest information as of April 2010.
## **C440/** _**XT**_ **Standalone Overload Relays (** _**XT**_ **, C440)**
||**Maximum**|**Standard-Fault**|**Short Circuit**<br>**Maximum**|**Data**<br>**Maximum**|**High-Fault Short Circuit Data**<br>**Fuses (RK5, J, CC)**|**High-Fault Short Circuit Data**<br>**Fuses (RK5, J, CC)**||**Thermal-Magnetic Circuit**|**Thermal-Magnetic Circuit**|**Breakers**|
|---|---|---|---|---|---|---|---|---|---|---|
|**Overload**|**Operating**||**Fuse Size (A)**|**Breaker**|||**Maximum**|||**Maximum**|
|**FLA Range**|**Voltage**|**600V (kA)**|**(RK5)**|**Size (A)**|**480V (kA)**|**600V (kA)**|**Fuse Size**|**480V (kA)**|**600V (kA)**|**Breaker Size**|
|0.33–1.65A|600 Vac|1|6|15|—|—|—|—|—|—|
|1–5A|600 Vac|5|20|20|100|100|30|100|35|20|
|4–20A<br>9–45A|600 Vac<br>600 Vac|5<br>5|80<br>175|80<br>175|100<br>100|100<br>100|100<br>100|100<br>100|35<br>35|80<br>100/175 (480/600)|
|20–100A|600 Vac|10|400|400|100|100|200|150|35|250/400 (480/600)|
|28–140A|600 Vac|10|450|500|100|100|400|100|65|400|
|35–175A|690 Vac|10|500 (gG)|350 (690 Vac)|100|100|500 (gG)|100 (415 Vac)|—|350 (LGC3350)|
|||||320 (415 Vac)||||||320 (NZMH3)|
## **IEC** _**XT**_ **Starters with** _**XT**_ **Electronic Overload Relays**
|**Contactor**<br>**Frame Size**|**Maximum**<br>**Operating**<br>**Voltage**<br>**High-Fault Short Circuit Data**<br>**Thermal-Magnetic Circuit Breakers**<br>**Fuses (RK5, J, CC)**<br>**480V**<br>**600V**<br>**Maximum**<br>**Fuse Size**<br>**480V**<br>**600V**<br>**Maximum**<br>**Breaker Size**|
|---|---|
|B|1–5A<br>100<br>100<br>30<br>—<br>—<br>—|
||4–20A<br>100<br>100<br>30<br>—<br>—<br>—|
|C|1–5A<br>100<br>100<br>60<br>—<br>—<br>—|
||4–20A<br>100<br>100<br>60<br>—<br>—<br>—|
||9–45A<br>100<br>100<br>60<br>—<br>—<br>—|
|D|9–45A<br>100<br>100<br>200<br>65<br>35<br>175|
||20–100A<br>100<br>100<br>200<br>65<br>35<br>175|
|F|20–100A<br>100<br>100<br>200<br>65<br>65<br>350|
|G|20–100A<br>100<br>100<br>200<br>65<br>65<br>350|
||35–175A<br>100<br>100<br>400<br>65<br>30<br>250 (480 Vac)<br>350 (600 Vac)|
|H|35–175A<br>100<br>100<br>400<br>65<br>30<br>400|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-154**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **45 mm C440/** _**XT**_ **Electronic Overload Relays**
|A|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||**Text O**||||||
||||||||||||||||
||||||||B<br>B||||||||
|||||||||1<br>|||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
|**Width**<br>**A**<br>**Depth**<br>**B1**|||**B**|||**Mounting Holes**<br>**(Height) C**|||||||||
|**tarter Size**|||||||||||||||
|1.80 (45.7)<br>4.32 (109.7)|||4.63 (117.5)|||3.68 (93.5)|||||||||
|**rame Size**|||||||||||||||
|1.80 (45.7)<br>4.00 (101.6)|||4.30 (109.2)|||3.68 (93.5)|||||||||
|**one**|||||||||||||||
|1.80 (45.7)<br>4.30 (109.2)|||4.60 (116.8)|||3.68 (93.5)|||||||||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-155**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in Inches (mm)
**55 mm C440/** _**XT**_ **Electronic Overload Relays**
|C<br>A|B||||
|---|---|---|---|---|
||||||
||||||
|**Width**<br>**A**|**Height To Reset**<br>**B**||**B1**||
|**Starter Size**|||||
|2.21 (56.0)|5.52 (140.2)||5.21 (132.4)|4.13 (104.8)|
|**Frame Size**|||||
|2.21 (56.0)|5.52 (140.2)||5.21 (132.4)|4.13 (104.8)|
|**one**|||||
|2.21 (56.0)|5.52 (140.2)||5.21 (132.4)|4.13 (104.8)|
**110 mm C440/** _**XT**_ **Electronic Overload Relays**
|||||||||C|||B|1|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||
||||||||||||||
|||||||||C|||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||B||
|||A|||||||||||
||||||||||||||
|**Width**<br>**A**||**Height To Reset**<br>**B**|**B1**|**Mounting Depth**<br>**C**|||||||||
|**Starter Size**|||||||||||||
|4.33 (110.0)||6.20 (157.0)|5.90 (150.0)|6.00 (152.0)|||||||||
|**Frame Size**|||||||||||||
|4.33 (110.0)||6.20 (157.0)|5.90 (150.0)|6.00 (152.0)|||||||||
|4.33 (110.0)||6.20 (157.0)|5.90 (150.0)|6.00 (152.0)|||||||||
|**one**|||||||||||||
|4.33 (110.0)||6.20 (157.0)|5.90 (150.0)|6.00 (152.0)|||||||||
|**rough**|||||||||||||
|4.33 (110.0)||5.90 (149.0)|5.60 (142.0)|4.00 (102.0)|||||||||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-156**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **Manual Motor Protectors**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .<br>Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**<br>**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .<br>Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**<br>**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .<br>Manual Motor Protectors|**V5-T1-141**|
|Features and Benefits . . . . . . . . . . . . . . . . . . .|**V5-T1-158**|
|Standards and Certifications . . . . . . . . . . . . . .|**V5-T1-158**|
|Product Identification . . . . . . . . . . . . . . . . . . . .|**V5-T1-159**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-160**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-161**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V5-T1-164**<br>**V5-T1-174**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-183**<br>**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .<br>EMS—Electronic Motor Starter . . . . . . . . . . . . . . .|**V5-T1-217**<br>**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**<br>**V5-T1-234**|
**1**
## **Manual Motor Protectors**
## **Product Description**
Eaton’s new _**XT**_ family of manual motor protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class 10 adjustable bimetallic overload relay and fixed magnetic short-circuit trip capability in one compact unit. Two frame sizes are available: Frame B (45 mm) for motors with FLA ratings up to 32A and Frame D (55 mm) covers motor FLA ratings up to 65A.
## **Application Description**
The XTPB and XTPR MMPs can be used in the following applications.
## _**Motor Protective Circuit Breaker**_
In many countries outside of the United States and Canada, especially Europe, the MMPs are tested and classified as thermalmagnetic circuit breakers for use in motor branch circuits. This can be an important consideration for all companies who export their equipment and machines internationally. Both the XTPB and XTPR conform to IEC/EN 60947 and have the CE Mark.
## _**Manual Motor Protectors**_
The XTPB and XTPR MMPs are UL listed under UL 508 as manual motor protectors. They provide an economical solution for applications requiring simple manual starting and stopping of motors. When used as a manual starter, they are typically installed in an enclosure. Many enclosures are offered as accessories for the MMPs. Separate shortcircuit protective devices, such as circuit breakers or fuses, are wired ahead of the MMPs. The short-circuit protective device should be sized per the NEC and should not exceed 400% of the maximum FLA dial setting of the MMP.
## _**Group Motor Installations**_
A group motor installation can be defined as more than one motor circuit protected by a single set of fuses or circuit breaker on a motor branch circuit. This eliminates the need for individual fuses or circuit breakers for each motor circuit. Substantial component cost savings, panel space savings and reduced wiring installation time can be achieved in group motor installations.
The MMPs are tested and listed for group installation. If remote operation is required, a magnetic contactor can be wired in series with the MMP.
Article 430.53 of the NEC contains the rules and requirements for group motor installations. Refer to application note AP03402001E for NEC requirement for group motor installation.
## _**Individual Branch Motor Applications**_
A UL 508 Type E selfprotected manual combination starter/motor controller consists of a single device possessing four essential elements: disconnect, short circuit protection, motor controller, and motor overload protection. Some MMPs require use of a lineside adapter for this type of approval. When tested as an official combination by UL, this device takes the place of a fuse-starter or breakerstarter, _**XT**_ Type E MMPs are self-protected, meaning they do not need additional short circuit protection of a fuse or breaker. Type E devices can also be used with a contactor or other types of UL approved controllers. If tested with a contactor, the combination motor controller becomes a Type F device. See **Page V5-T1-197** for XTFC Type F devices.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-157**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Features and Benefits**
- ON/OFF rotary handle with lockout provision
- Visible trip indication
- Class 10 overload protection
- Phase loss sensitivity
- Ambient temperature compensation to IEC/EN 60947, VDE 0660
- Fixed short-circuit trip— 14 times maximum setting of overload FLA dial
- Type 2 coordination per IEC 947
- Identification markers standard on starter faceplate
- Motor applications from 0.1A to 65A
- Built-in heater and magnetic trip elements to protect the motor
## **Standards and Certifications**
- Adjustment dial for setting motor FLA
- DIN rail mount
- Terminal types available:
- Screw terminals
- Screw (line) and spring cage (load) terminals
- Spring cage terminals
- Accessories include:
- Front and side auxiliary contacts
- Trip indicating contacts
- Tamperproof cover for OLR dial
- Undervoltage release
- Shunt trip
- Through-the-door operators
- Enclosures
- Three-phase line side connecting links
## **Line Side Adapters—When to Use Them**
**Note:** Line side adapters are not required for non-US applications. Most countries outside of the US classify the MMP as a thermal magnetic circuit breaker.
**==> picture [239 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
Manual Motor Protectors<br>Self-Protected Manual Combination Starters<br>Group Installation UL 508 Type E Self-Protected Manual<br>Upstream SCPD required. Combination Starter<br>Self-protected. No additional SCPD needed in<br>branch circuit.<br>Line Side Adapter (LSA) Line Side Adapter (LSA)<br>Not required Required<br>Line Side Adapter Line Side Adapter<br>XTPAXLSA XTPAXLSAD<br>MMP MMP<br>XTPR…BC1 XTPR…DC1<br>**----- End of picture text -----**<br>
**Manual Motor Protector and Line Side Adapter**
- ATEX
- CE approved
- UL listed File No. E36332
- UL listed File No. E123500
- UL 508 group motor and Type E compliant
- IEC/EN 60947
- CSA File 229767, Class 3211-05
- DIN VDE 0660 Part 100, Part 101 and Part 102
**Note:** For Type 2 Coordination of MMCs, see **Page V5-T1-235** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-158**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Product Identification**
**==> picture [323 x 357] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>4<br>2<br>5 5<br>3 Wy @ a<br>5<br>2<br>2<br>Bq 6<br>6<br>**----- End of picture text -----**<br>
_**Notes**_
## **Basic Units**
- 1 XTPB pushbutton manual motor protectors (see **Page V5-T1-161** ) Rated operational current up to 25A Switching capacity 50 kA/415V Short-circuit release, adjustable 0.6–1 x lu
- Single-phasing sensitive
- 2 XTPR rotary manual motor protectors (see **Page V5-T1-162** ) Rated operational current up to 32A, 65A
- Switching capacity 150/50 kA/415V Short-circuit release, fixed setting to 14 x lu
- Overload release, adjustable 0.6–1 x lu Single-phasing sensitive With screws or spring-loaded terminals
## **Mounting Accessories**
- 3 Rotary handle mechanism (see **Page V5-T1-167** )
- ON/OFF/tripped switch position indication Lockable door/cover interlock Extendable y plug fit extension shaft Handle latched in switch positions Optionally also without locking and door interlock function
## Insulated enclosures
(see **Page V5-T1-170** ) Surface mounting, enclosures, IP40,
- IP55 and IP40 and IP55 front flush mounting enclosure
- Mounting/wiring (see **Page V5-T1-167** ) Component adapter for busbar mounting Three-phase commoning link for side-by-side-mounting
- Mounting kits for rapid mounting of direct-on-line, reversing and stardelta starters
## **Add-On Functions**
- 4 Voltage releases (see **Page V5-T1-166** ) Undervoltage release Shunt releases
- With screws or spring-loaded terminals
- 5 Standard auxiliary contacts (see **Page V5-T1-164** )
- ON/OFF indication Differential fault indication overload/ short-circuit release
- ON/OFF for (high capacity) contact
module
ON/OFF for starter combination With early-make contacts With screws or spring-loaded terminals
- 6 Current limiter (see **Page V5-T1-166** ) Increases the switching capacity of the 10–25A manual motor protectors to 100 kA/440V
- Can be used for individual group protection
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-159**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **Manual Motor Protectors**
**XT PR 012 B C1 Designation Trip Class** _**XT**_ = _**XT**_ IEC power control **Type Frame Size C1** = Class 10 **PB** = Manual motor protector— **Current Ratings B** = 45 mm pushbutton **Frame B Frame D D** = 55 mm **PR** = Manual motor protector— **P16** = 0.16A **016** = 16A rotary **P25** = 0.25A **025** = 25A **P40** = 0.40A **032** = 32A **P63** = 0.63A **040** = 40A **001** = 1A **050** = 50A **1P6** = 1.6A **058** = 58A **2P5** = 2.5A **063** = 63A **004** = 4A **6P3** = 6.3A **010** = 10A **012** = 12A **016** = 16A **020** = 20A **025** = 25A **032** = 32A
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-160**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Product Selection**
## _**Product Selection for Manual Motor Starter Applications**_
When ordering, specify catalog numbers according to the following stipulations:
_**XT**_ manual motor protectors are selected based on the overload current range required for a given motor. This current range is determined from the motor full load ampere rating and motor service factor usually found on the motor nameplate.
**For motors with service factors less than 1.15,**
multiply the motor FLA by 0.90 to select appropriate MMP.
Example: For motor having FLA of 6.4A and service factor of 1.0 (6.4A x 0.90 = 5.76A) select catalog number XTPB6P3B01.
**For motor with service factor of 1.15 or greater,**
use motor nameplate full load amperes to select the appropriate MMP.
Example: For motor having FLA of 11A and service factor of 1.15, select catalog number XTPR012BC1.
See Application Note— AP03402001E.
## **Frame B**
**XTPB Pushbutton Manual Motor Protectors—Global and North American Ratings—Frame B** Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip
|**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu = Ie (Amps)**|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**FLA**<br>**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~[2]~~|**Maximum Motor Ratings**1<br>**500V**|**660–**<br>**690V**|**Maximum hp Rating—P (hp)**<br>**UL 508/CSA C22.2 No. 14**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V**|**Maximum hp Rating—P (hp)**<br>**UL 508/CSA C22.2 No. 14**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V**|**Maximum hp Rating—P (hp)**<br>**UL 508/CSA C22.2 No. 14**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V**|**Maximum hp Rating—P (hp)**<br>**600V**|**Screw Terminal**<br>**Catalog Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|0.16|0.1–0.16<br>2.2||||—|—|—|—|0.06|2|2|2|2|**XTPBP16BC1**|
|0.25<br>0.4|0.16–0.25<br>3.5<br>0.25–0.4<br>5.6||||—<br>0.06|0.06<br>0.09|0.06<br>0.12|0.06<br>0.12|0.12<br>0.18|2<br>2|2<br>2|2<br>2|2<br>2|**XTPBP25BC1**<br>**XTPBP40BC1**|
|0.63|0.4–0.63<br>8.8||||0.09|0.12|0.18|0.25|0.25|2|2|2|2|**XTPBP63BC1**|
|1|0.63–1||14||0.12|0.25|0.25|0.37|0.55|2|2|2|1/2|**XTPB001BC1**|
|1.6|1–1.6||22||0.25|0.55|0.55|0.75|1.1|2|2|3/4|3/4|**XTPB1P6BC1**|
|2.5|1.6–2.5||35||0.37|0.75|1.1|1.1|1.5|1/2|1/2|1|1-1/2|**XTPB2P5BC1**|
|4|2.5–4||56||0.75|1.5|1.5|2.2|3|3/4|3/4|2|3|**XTPB004BC1**|
|6.3<br>10|4–6.3<br>6.3–10||88<br>140||1.1<br>2.2|2.2<br>4|3<br>4|3<br>4|4<br>7.5|1<br>3|1-1/2<br>3|3<br>7-1/2|5<br>10|**XTPB6P3BC1**<br>**XTPB010BC1**|
|12|8–12||168||3|5.5|5.5|5.5|11|3|3|7-1/2|10|**XTPB012BC1**|
|16|10–16||224||4|7.5|9|9|12.5|3|5|10|10|**XTPB016BC1**|
|20|16–20||280||5.5|9|11|12.5|15|5|—|—|15|**XTPB020BC1**|
|25|20–25||350||5.5|12.5|12.5|15|22|—|7-1/2|15|20|**XTPB025BC1**|
## _**Notes**_
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor: SF = 1.15 → Ir = 1 x In mot SF = 1 → Ir = 0.9 x In mot
For manual motor protective circuit breaker switching capacity, see **Page V5-T1-179** .
1 Select manual motor protectors by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-161**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Frame B**
## **XTPR Rotary Manual Motor Protectors with Screw Terminals— Global Ratings and North American Ratings—Frame B**
Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip
||**FLA**||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu = Ie (Amps)**|**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~cH~~|||||||**Maximum Motor Ratings**1<br>**500V**|**660–**<br>**690V**|**Maximum hp Rating—P (hp)**<br>**UL 508/CSA C22.2 No. 14**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V**|||**Maximum hp Rating—P (hp)**<br>**600V**|**Screw Terminal**<br>**Catalog Number**|
|0.16|0.1–0.16<br>2.2||||—|—|—|—|0.06|2|2|2|2|**XTPRP16BC1**|
|0.25|0.16–0.25<br>3.5||||—|0.06|0.06|0.06|0.12|2|2|2|2|**XTPRP25BC1**|
|0.4<br>0.63|0.25–0.4<br>5.6<br>0.4–0.63<br>8.8||||0.06<br>0.09|0.09<br>0.12|0.12<br>0.18|0.12<br>0.25|0.18<br>0.25|2<br>2|2<br>2|2<br>2|2<br>2|**XTPRP40BC1**<br>**XTPRP63BC1**|
|1|0.63–1||14||0.12|0.25|0.25|0.37|0.55|2|2|2|2|**XTPR001BC1**|
|1.6|1–1.6||22||0.25|0.55|0.55|0.75|1.1|2|2|3/4|3/4|**XTPR1P6BC1**|
|2.5|1.6–2.5||35||0.37|0.75|1.1|1.1|1.5|1/2|1/2|1|1-1/2|**XTPR2P5BC1**|
|4|2.5–4||56||0.75|1.5|1.5|2.2|3|3/4|3/4|2|3|**XTPR004BC1**|
|6.3|4–6.3||88||1.1|2.2|3|3|4|1|1-1/2|3|5|**XTPR6P3BC1**|
|10<br>12|6.3–10<br>8–12||140<br>168||2.2<br>3|4<br>5.5|4<br>5.5|4<br>5.5|7.5<br>11|3<br>3|3<br>3|7-1/2<br>7-1/2|10<br>10|**XTPR010BC1**<br>**XTPR012BC1**|
|16|10–16||224||4|7.5|9|9|12.5|3|5|10|10|**XTPR016BC1**|
|20|16–20||280||5.5|9|11|12.5|15|5|—|—|15|**XTPR020BC1**|
|25|20–25||350||5.5|12.5|12.5|15|22|—|7-1/2|15|20|**XTPR025BC1**|
|32|25–32||448||7.5|15|15|22|30|7-1/2|10|20|25|**XTPR032BC1**|
## **Frame D**
## **XTPR Rotary Manual Motor Protectors with Screw Terminals— Global Ratings and North American Ratings—Frame D**
Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip
||**FLA**||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu = Ie (Amps)**|**Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**<br>**Maximum kW Rating**<br>**AC-3—P (kW)**<br>**Three-Phase**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**440V**<br>~~Es~~||||||**Maximum Motor Ratings**1<br>**500V**|**660–**<br>**690V**|**Maximum hp Rating—P (hp)**<br>**UL 508/CSA C22.2 No. 14**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V**||**Maximum hp Rating—P (hp)**<br>**600V**|**Screw Terminal**<br>**Catalog Number**|
|16|10–16||224||4<br>7.5|9|9|12.5|3<br>5|10|15|**XTPR016DC1**|
|25|16–25||350||5.5<br>12.5|12.5|15|22|7-1/2<br>7-1/2|15|20|**XTPR025DC1**|
|32|25–32||448||7.5<br>15|17.5|22|22|10<br>10|20|30|**XTPR032DC1**|
|40<br>50|32–40<br>40–50||560<br>700||11<br>20<br>14<br>25|22<br>30|24<br>30|30<br>45|10<br>15<br>10<br>15|30<br>30|30<br>40|**XTPR040DC1**<br>**XTPR050DC1**|
|58|50–58||812||17<br>30|37|37|55|15<br>15|40|50|**XTPR058DC1**|
|65|55–65||882||18.5<br>34|37|45|55|15<br>15|40|50|**XTPR063DC1**|
## _**Notes**_
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor:
- SF = 1.15 → Ir = 1 x In mot
SF = 1 → Ir = 0.9 x In mot
For manual motor protective circuit breaker switching capacity, see **Page V5-T1-179** .
- 1 Select manual motor protectors by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
- 2 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-162**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|**Frame B**|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**<br>Motor Protective Device with Thermal and Magnetic Trip|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**|**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B**1|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|tL.|**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu (Amps)**|**FLA Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>~~4~~|||**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**|||||**Rated Short-Circuit**<br>**Breaking Capacity (kA)**<br>**480/**<br>**277V**<br>**600/**<br>**347V**||**Line Side**<br>**Adapter**1<br>**Catalog Number**|**Manual Motor**<br>**Protector—**<br>**Screw Terminal**<br>**Catalog Number**|
||0.16<br>0.25|0.1–0.16<br>0.16–0.25|||2.2<br>3.4||3<br>3<br>3<br>3|1/2<br>1/2|1/2<br>1/2|50<br>50|50<br>50|**XTPAXLSA**<br>**XTPAXLSA**|**XTPRP16BC1**<br>**XTPRP25BC1**|
||0.4<br>0.63|0.25–0.4<br>0.4–0.63|||5.6<br>8.8||3<br>3<br>3<br>3|1/2<br>1/2|1/2<br>1/2|50<br>50|50<br>50|**XTPAXLSA**<br>**XTPAXLSA**|**XTPRP40BC1**<br>**XTPRP63BC1**|
||1<br>1.6|0.63–1<br>1–1.6|||14<br>22||3<br>3<br>3<br>3|1/2<br>3/4|1/2<br>3/4|50<br>50|50<br>50|**XTPAXLSA**<br>**XTPAXLSA**|**XTPR001BC1**<br>**XTPR1P6BC1**|
||2.5|1.6–2.5|||35||1/2<br>1/2|1|1-1/2|50|50|**XTPAXLSA**|**XTPR2P5BC1**|
||4|2.5–4|||56||3/4<br>1|2|3|50|50|**XTPAXLSA**|**XTPR004BC1**|
||6.3|4–6.3|||88||1<br>1-1/2|3|5|65|50|**XTPAXLSA**|**XTPR6P3BC1**|
||10|6.3–11|||140||3<br>3|7-1/2|10|65|50|**XTPAXLSA**|**XTPR010BC1**|
||12|8–12|||168||3<br>3|7-1/2|—|65|—|**XTPAXLSA**|**XTPR012BC1**|
||16|10–16|||224||3<br>5|10|—|42|—|**XTPAXLSA**|**XTPR016BC1**|
||20|16–20|||280||5<br>5|—|—|18|—|**XTPAXLSA**|**XTPR020BC1**|
||25<br>32|20–25<br>25–32|||350<br>448||5<br>7-1/2<br>7-1/2<br>10|15<br>25|—<br>—|18<br>18|—<br>—|**XTPAXLSA**<br>**XTPAXLSA**|**XTPR025BC1**<br>**XTPR032BC1**|
## **Frame D**
## **XTPR Circuit Breaker According to UL 489—Frame D**
|**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu (Amps)**|**FLA Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**|**FLA Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**|**Rated Short-Circuit**<br>**Breaking Capacity (kA)**<br>**240V**<br>**480/**<br>**277V**<br>**600/**<br>**347V**|**Rated Short-Circuit**<br>**Breaking Capacity (kA)**<br>**240V**<br>**480/**<br>**277V**<br>**600/**<br>**347V**|**Manual Motor**<br>**Protector—**<br>**Screw Terminal**<br>**Catalog Number**|
|---|---|---|---|---|---|---|---|---|---|
|16|10–16||224||3<br>5|10<br>10|65<br>65|25|**XTPR016DCB**|
|25|16–25||350||7-1/2<br>7-1/2|20<br>25|65<br>65|25|**XTPR025DCB**|
|32|24–32||448||10<br>10|25<br>30|65<br>65|25|**XTPR032DCB**|
**Frame D**
**XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame D**[1] Motor Protective Device with Thermal and Magnetic Trip
|**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu (Amps)**<br>16<br>25<br>32|**FLA Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>10–16<br>16–25<br>25–32|**FLA Adjustment**<br>**Range/**<br>**Overload**<br>**Release—**<br>**Ir (Amps)**<br>10–16<br>16–25<br>25–32|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**<br>224<br>3<br>5<br>10<br>10<br>350<br>7-1/2<br>7-1/2<br>20<br>25<br>448<br>10<br>10<br>25<br>30|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**<br>224<br>3<br>5<br>10<br>10<br>350<br>7-1/2<br>7-1/2<br>20<br>25<br>448<br>10<br>10<br>25<br>30|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**<br>224<br>3<br>5<br>10<br>10<br>350<br>7-1/2<br>7-1/2<br>20<br>25<br>448<br>10<br>10<br>25<br>30|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Motor Ratings**2<br>**Maximum hp Rating—P (hp)**<br>**Three-Phase**<br>**200V**<br>**240V**<br>**480V/**<br>**277V**<br>**600V/**<br>**247V**<br>224<br>3<br>5<br>10<br>10<br>350<br>7-1/2<br>7-1/2<br>20<br>25<br>448<br>10<br>10<br>25<br>30|**Rated Short-Circuit**<br>**Breaking Capacity (kA)**<br>**240V**<br>**480/**<br>**277V**<br>**600/**<br>**347V**<br>65<br>65<br>25<br>65<br>65<br>25<br>65<br>65<br>25|**Rated Short-Circuit**<br>**Breaking Capacity (kA)**<br>**240V**<br>**480/**<br>**277V**<br>**600/**<br>**347V**<br>65<br>65<br>25<br>65<br>65<br>25<br>65<br>65<br>25|**Line Side**<br>**Adapter**1<br>**Catalog Number**<br>**XTPAXLSAD**<br>**XTPAXLSAD**<br>**XTPAXLSAD**|**Manual Motor**<br>**Protector—**<br>**Screw Terminal**<br>**Catalog Number**<br>**XTPR016DC1**<br>**XTPR025DC1**<br>**XTPR032DC1**|
|---|---|---|---|---|---|---|---|---|---|---|
|40<br>50|32–40<br>40–50||560<br>700||10<br>—<br>—<br>15|30<br>30<br>30<br>—|65<br>65|65<br>25<br>65<br>—|**XTPAXLSAD**<br>**XTPAXLSAD**|**XTPR040DC1**<br>**XTPR050DC1**|
|58|50–58||812||—<br>—|40<br>—|65|65<br>—|**XTPAXLSAD**|**XTPR058DC1**|
|65|55–65||882||—<br>—|40<br>—|65|65<br>—|**XTPAXLSAD**|**XTPR063DC1**|
## _**Notes**_
A UL 508 Type E self-protected manual combination starter (XTPR) consists of a manual motor protector (XTPR) and a UL Listed line side adapter (for example, XTPAXLSA). The Type E self-protected manual combination starter alone is a legitimate short-circuit protective device and disconnect means for the downstream motor, while the contactor has been added to provide remote operation of the motor circuit. Conductor size for XTPAXLSA is 14–6 AWG, XTPAXLSAD is 8 AWG–1/0.
1 UL 508 Type E starters are assembled from a standard XTPR and a special incoming terminal line side adapter (XTPAXLSA or XTPAXLSAD).
2 Select manual motor protectors by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
- 3 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-163**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Accessories**
## _**Auxiliary Contacts**_
## **XTPAXSA_**
## **Side-Mount Auxiliary Contacts**
**==> picture [311 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contact Pkg. Screw Terminal<br>Configuration Contact Sequence Qty. [1] Catalog Number<br>1NO-1NC ° i ee 1.13 1.21 5 XTPAXSA11<br>L1 L2 L3<br>XTPAXSA11 A ey<br>leq !<br>ee| |<br>1.14 1.22<br>1NO-2NC 1.13 1.21 1.31 5 XTPAXSA12<br>a L1 L2 L3 fe) 1 ee| i<br>XTPAXSA12 a +o] [| HH4-----4 | |<br>tr Po} ; Fie] !<br>| |<br>1.14 1.22 1.32<br>2NO-1NC fe) I 1.13 1.21 1.33 5 XTPAXSA21<br>[ L1 L2 L3 TTT en<br>XTPAXSA21 = HH 4----4<br>es ee<br>| |<br>1.14 1.22 1.34<br>**----- End of picture text -----**<br>
Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and XTPAXFA_ trip indicating auxiliary contact.
## **XTPAXFA11**
## **Front-Mount Auxiliary Contacts**
||**Contact**|||||||||||||||||**Pkg.**|**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|=<br>Cy <br>a,|**Configuration**<br>**Contact Sequence**<br>**Qty.**1<br>**Catalog Number**<br>1NO-1NC<br>5<br>**XTPAXFA11**<br>1.53 1.61<br>L1 L2 L3<br>XTPAXFA11<br> ~~SS~~<br>fe}<br>f<br>~~a~~<br>~~en~~<br>~~oe~~|||||||||||||||||||
|||||||||||;<br>~~Eto]~~<br>~~jus~~||||1.54 1.62<br>'<br>|||||||
Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR…B and XTPB) or 55 mm (XTPR…D) widths of manual motor protectors remain unchanged.
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-164**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTPAXSATR_**
## **Side-Mount Trip Indicating Auxiliary Contacts**
|**Contact**|||||||||**Pkg.**|**For Use**||
|---|---|---|---|---|---|---|---|---|---|---|---|
|**Configuration**|**Contact Sequence**||||||||**Qty.**1|**with…**|**Catalog Number**|
|2 x 1NO|“+”||“ ”<br>I>||||||2|XTPB, XTPR,|**XTPAXSATR20**|
||4.44 <br>4.43<br>~~a~~<br>~~Ho)~~<br>|<br>i ~~Ley~~<br>~~—.~~||4.14<br>4.13|||||||XTPM, XTPT||
||On/Off|||||||||||
||a~~S~~|||||||||||
||L1L2L3<br>~~fe)~~||||~~1~~|||||||
||“+”<br>“>”<br>~~eee~~<br>a<br>~~nl~~|||||||||||
||Trip “+”<br>L1L2L3<br>~~—_—~~<br>~~fe)~~||||~~1~~|||||||
||“+”|||~~TH~~||||||||
||“>”<br>_<br>~~—~~i~~a~~|||||||||||
|||||||||||||
|2 x 1NC|“+”||“ ”<br>I>||||||2|XTPB, XTPR,|**XTPAXSATR02**|
||4.31<br>~~4~~<br>~~HH~~<br>|<br>~~lin~~d||4.21|||||||XTPM, XTPT||
|||||||||||||
|||||||||||||
||4.32||4.22|||||||||
||On/Off|||||||||||
||+|||||||||||
||°||||I|||||||
||L1L2L3|||||||||||
||“+”<br>“>”<br>~~—~Y~~||||||||||||
||Trip “+”|||||||||||
||~~—_—~~|||||||||||
||“+”<br>“>”<br>L1L2L3<br>~~fe}~~<br>~~CT~~<br>~~=~~<br>~~~T~~|||||~~|~~||||||
Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable.
## **Early-Make Front-Mount Auxiliary Contacts**
**==> picture [386 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contact Pkg. For Use<br>Configuration Contact Sequence Qty. [1] with… Catalog Number<br>XTPBXFAEM20 2NO 3.13 3.23 5 XTPB XTPBXFAEM20<br>fp<br>enn Soa HEA<br>= lic |<br>3.14 3.24<br>XTPAXFAEM20 2NO 2 XTPR… NL, PKZM XTPAXFAEM20 [23]<br>**----- End of picture text -----**<br>
For use with XTPB_, Frame B XTPR and XTPT. Can be fitted to the front of a manual motor protector. 45 mm width of manual motor protector remains unchanged. For early energization of undervoltage release, for example, in emergency-stop circuits to EN 60204.
## _**Notes**_
- 1 Orders must be placed in multiples of package quantity listed.
- 2 Not for use with rotary handle mechanism.
- 3 Not compatible with XTPR lockable handle, order PKZM0 or XTPR… NL. NL is the non-lockable handle version.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-165**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Additional Accessories**_
|**XTPAXSR_**|**XTPAXSR_**|**XTPAXSR_**|**XTPAXSR_**|**XTPAXSR_**|**XTPAXSR_**|**Shunt Release**<br>**Pkg.**|**Screw Terminal**|**XTPAXUVR_**|**XTPAXUVR_**|**XTPAXUVR_**|**XTPAXUVR_**|**XTPAXUVR_**|**XTPAXUVR_**|**Undervoltage Release**<br>**Pkg.**<br>**Screw Terminal**|**Undervoltage Release**<br>**Pkg.**<br>**Screw Terminal**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||**Qty.**1<br>2|**Catalog Number**<br>**XTPAXSR24V50H**|||||||**Qty.**1<br>2|**Catalog Number**<br>**XTPAXUVR24V50H**|
|||||||2|**XTPAXSR48V50H**|||||||2|**XTPAXUVR24V60H**|
|||||||2|**XTPAXSR110V50H**|||||||2|**XTPAXUVR48V50H**|
|**Contact Sequence**||||||2|**XTPAXSR120V60H**|**Contact Sequence**||||||2|**XTPAXUVR60V50H**|
|||C1||||2|**XTPAXSR208V60H**|||D1||||2|**XTPAXUVR110V50H**|
|||||||2|**XTPAXSR220V50H**|||||||2|**XTPAXUVR120V60H**|
|||||||2<br>2|**XTPAXSR230V50H**<br>**XTPAXSR240V50H**|||U||||2<br>2|**XTPAXUVR208V60H**<br>**XTPAXUVR220V50H**|
|||C2||||||||D2||||||
|||||||2|**XTPAXSR240V60H**|||||||2|**XTPAXUVR230V50H**|
|||||||2|**XTPAXSR380V50H**|||||||2|**XTPAXUVR240V50H**|
|||||||2|**XTPAXSR400V50H**|||||||2|**XTPAXUVR240V60H**|
|||||||2|**XTPAXSR415V50H**|||||||2|**XTPAXUVR380V50H**|
|||||||2|**XTPAXSR440V60H**|||||||2|**XTPAXUVR400V50H**|
|||||||2|**XTPAXSR480V60H**|||||||2|**XTPAXUVR415V50H**|
|||||||2|**XTPAXSR24VDC**|||||||2|**XTPAXUVR440V60H**|
|||||||2|**XTPAXSR48VDC**|||||||2|**XTPAXUVR480V60H**|
|||||||2|**XTPAXSR60VDC**|||||||2|**XTPAXUVR600V60H**|
|||||||2<br>2<br>2|**XTPAXSR110VDC**<br>**XTPAXSR125VDC**<br>**XTPAXSR220VDC**|||||||Can be used to trip the manual motor<br>protector from a remote location. Can<br>be fitted on left side manual motor||
|||||||2|**XTPAXSR250VDC**|||||||protectors. Cannot be combined with<br>XTPAXSR. When combined with a circuit||
Can be used to trip the manual motor protector from a remote location. Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When combined with a circuit breaker, it can be used as emergency-stop device to IEC/EN 60204.
Can be used to trip the manual motor protector from a remote location. Can be fitted on the left side of manual motor protectors. Cannot be combined with the XTPAXUVR. DC: Intermittent operation 5 sec.
## **XTPAXCL**
## **Current Limiter**[2]
|**Current Limiter**[2]|**Current Limiter**[2]|**Current Limiter**[2]|||
|---|---|---|---|---|
|**Description**<br>**Contact**<br>**Sequence**|||**Pkg.**<br>**Qty.**1|**Catalog Number**|
|To enhance the switching capacity of non-inherently<br>safe 10–25A manual motor protectors to 150 kA/440V|L||1|**XTPAXCL**|
||||||
||T||||
The XTPAXCL enhances the switching capacity of the XT manual motor protectors. It can be used with the XTPB, XTPR…BC1, XTPR…DC1 for individual or group protections. The rated uninterrupted current is 63A for IEC and 25A for UL/CSA. It can be mounted next to or behind the manual motor protector. See **Page V5-T1-179** for ratings when using the current limiter.
## _**Notes**_
- 1 Orders must be placed in multiples of package quantity listed.
- 2 Max. rated operation voltage Ue = 690V, rated uninterrupted current Iu = 63A. Can be used for individual and group protection. For group protection and in combination with the XTPR…D order additional XTPAXIT incoming terminal if required. Mounting next to or behind the manual motor protector. 16–63A XTPR…D: 100 kA/400V, 10 kA/690V.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-166**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**IP65 Rotary Handle Mechanism**[1234]
||**IP65 Rotary Handle Mechanism**[1234]||||
|---|---|---|---|---|
|||**Enclosure**|**Pkg.**||
||**Description**|**Rating**|**Qty.**5|**Catalog Number**|
|**XTPAXRHM_**|**Complete Kits—Includes Handle, Shaft and Required Hardware**|**Complete Kits—Includes Handle, Shaft and Required Hardware**|||
|Bo!|Rotary handle mechanism—black6<br>Rotary handle mechanism—red/yellow7<br>Rotary handle mechanism—black—rotated 90° from vertical6|IP65<br>NEMA 12<br>UL/CSA 4X|1<br>**XTPAXRHMB**<br>1<br>**XTPAXRHMRY**<br>1<br>**XTPAXRHM90B**<br>~~——~~||
||Rotary handle mechanism—red/yellow—rotated 90° from||1|**XTPAXRHM90RY**|
||vertical7||||
|**XTPAXRHMSFT**|**Separate Parts**||||
|Shaft only—includes shaft to mount to XTPR, 175 mm length<br>—<br>10<br>**XTPAXRHMSFT**<br>MMP shaft support, metal, D-frame MMP only<br>—<br>1<br>**XTPAXMBM**<br>~~a~~|||||
||Replacement lockable handle for XTPR|—|1|**XTPAXLRH**|
|**XTPAXSW**|**Sealing Facility**||||
||||**Pkg.**||
||**Description**||**Qty.**5|**Catalog Number**|
||To prevent tampering with the overload release and the test function.|To prevent tampering with the overload release and the test function.|5|**XTPAXSW**|
||It can be sealed using industry standard sealing wire. For use with||||
||XTPR manual motor protectors.||||
## **Three-Phase Commoning Links**[8]
||||**Three-Phase Commoning Links**[8]|
|---|---|---|---|
||||**Qty.**<br>**MMP**<br>**Pkg.**|
||||**For Use with…**<br>**MMP**<br>**Frame Size**<br>**Qty.**5<br>**Catalog Number**|
|MMP with no side-mounted auxiliaries or voltage<br>releases<br>2<br>B<br>10<br>**XTPAXCLKA2**<br>D<br>1<br>**XTPAXCLKA2D**<br>3<br>B<br>10<br>**XTPAXCLKA3**<br>D<br>1<br>**XTPAXCLKA3D**<br>4<br>B<br>10<br>**XTPAXCLKA4**<br>~~C—O~~<br>~~aad~~<br>~~ee~~<br>~~ee~~||||
|D<br>1<br>**XTPAXCLKA4D**<br>5<br>B<br>10<br>**XTPAXCLKA5**<br>~~Sp~~<br>~~a~~||||
|~~— ~~<br>~~Sa~~|||Each MMP with one auxiliary contact or trip-indicating<br>auxiliary contact fitted on the right<br>2<br>B<br>10<br>**XTPAXCLKB2**<br>D<br>1<br>**XTPAXCLKB2D**<br>3<br>B<br>10<br>**XTPAXCLKB3**<br> ~~TN~~<br>~~SEE~~|
|D<br>1<br>**XTPAXCLKB3D**<br>4<br>B<br>10<br>**XTPAXCLKB4**<br>D<br>1<br>**XTPAXCLKB4D**<br>5<br>B<br>10<br>**XTPAXCLKB5**<br>~~a~~<br>~~a~~<br>~~la~~<br>~~BO~~||||
|~~— ~~|||Each MMP with an auxiliary contact and trip-indicating<br>2<br>B<br>10<br>**XTPAXCLKC2**<br> ~~a~~|
||||auxiliary contact mounted on the right or a voltage<br>release mounted on the left.<br>4<br>D<br>1<br>**XTPAXCLKC4D**|
For parallel power feed to several manual motor protectors on terminals 1, 3 and 5.
## _**Notes**_
- 1 Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 100–240 mm. Carrier with extension shaft included.
- 2 With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4–8 mm hasp. Can be locked in the OFF position, if required.
- 3 Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock.
- 4 Not for use with XTPAXFAEM20 early-make front-mount auxiliary contact.
- 5 Orders must be placed in multiples of package quantity listed.
- 6 For use on main switches to IEC/EN 60204.
- 7 For use on main switches with emergency-stop function to IEC/EN 60204.
- 8 Protected against accidental contact. Frame B short-circuit proof Ue = 690V, Iu = 63A. Frame B links can be combined by rotating mounting.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-167**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**|**XTPAXUTS**||||**Shroud for Unused Terminals of Three-Phase Commoning Links**<br>**Pkg.**|**Shroud for Unused Terminals of Three-Phase Commoning Links**<br>**Pkg.**|**Shroud for Unused Terminals of Three-Phase Commoning Links**<br>**Pkg.**|**Catalog**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||||||**For Use with…**<br>**Description**<br>**Qty.**1<br>Frame B XTPR<br>To cover unused terminals on three-phase commoning link.<br>20|||**Number**<br>**XTPAXUTS**|||
||||||||||||||||||||Protected against direct contact.||||||
|**XTPAXIT**|||||||||||||||||||**Incoming Terminals for Three-Phase**<br>**Commoning Link**2||||||
|||||||||||.es|es||||||||**For Use with…**<br>**Pkg.**<br>**Qty.**1<br>**Catalog**<br>**Number**||||||
||||||||||||||||||||Frame B XTPR, XTPB<br>5<br>**XTPAXIT**||||||
||||||||||||||||||||**Line-Side Adapters**3||||||
||||||||||||||||||||**Catalog**|||||**Catalog**|
||||||||||||||||||||**For Use with…**<br>**Number**||**For Use with…**|||**Number**|
|**XTPAXLSA**|||||||||||||||||||Frame B XTPR to create a UL 508 Type E/F<br>manual combination starter<br>**XTPAXLSA**<br>**XTPAXLSAD**||Frame D XTPR to create a UL 508<br>Type E/F manual combination starter|||**XTPAXLSAD**4|
|**XTPAXIP2X**|||||||||||||||||||Reduced size Frame D XTPR to create a UL 508<br>**XTPAXIP2X**||||||
||||||||||||||||||||Type E/F manual combination starter (not to be||||||
||||||||ty||||||||||||used with 3-phase commoning links)||||||
|||||||||||1||||||||||||||||
||||||||||||||||||||**_Combination Connection Kits_**||||||
||||||||||||||||||||**Non-Reversing Starters**||||||
||||||||||||||||||||**For Use with…**<br>**Description/Comprised of …**||||**Std.**<br>**Pack**1|**Catalog Number**|
|**XTPAXTPCB**|||||||||||||||||||XTPR…B + XTCE…B<br>Mechanical connection element for XTPR…B and contactor<br>Main current wiring between XTPR…B and contactor in toolless plug connection||||1<br>1|**XTPAXTPCB**|
||||||||||||||||||||Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables<br>up to 2.5 mm2external diameter or four cables up to 3.5 mm2external diameter.||||||
||||||||||||||||||||||||||
|**XTPAXEMCB**|||||||||||||||||||XTPR…B + XTCE…B<br>Mechanical connection element for XTPR…B and contactor<br>Main current wiring between XTPR…B and contactor screw in type connection||||1<br>1|**XTPAXEMCB**|
||||||||||||||||||||||||||
||||||||||||||||||||||||||
||||||||||||||||||||~~Be~~|~~Be~~|~~Be~~|~~Be~~|~~Be~~|~~Be~~|
|**XTPAXTPC_**|||||||||||||||||||XTPR…B + XTCE…C<br>DIN rail adapter plate<br>Main current wiring between XTPR and contactor|Main current wiring between XTPR and contactor|||1|**XTPAXTPCC**|
||||||||||||||||||||XTPR…D + XTCE…D<br>DIN rail adapter plate||||1|**XTPAXTPCD**|
||All<br>=||||||||||||||||||Main current wiring between XTPR and contactor|Main current wiring between XTPR and contactor|||||
||||||||||||||||||||**_Notes_**||||||
||||||||||||||||||||1Orders must be placed in multiples of package quantity listed.<br>2For three-phase commoning link, protected against accidental contact, Ue= 690V, Iu= 63A;||||||
||||||||||||||||||||For conductor cross-sections: 2.5–25 mm2stranded; 2.5–16 mm2flexible with ferrules, AWG 14-6.||||||
||||||||||||||||||||3XTPAXLSA is for three-phase commoning link, finger and back-of-hand proof,<br>Ue= 690V, Iu= 60A for conductor cross sections: 2.5–25 mm2stranded,||||||
||||||||||||||||||||2.5–16 mm2flexible with ferrule, AWG 14-6.||||||
||||||||||||||||||||4XTPAXLSAD cannot be combined with three-phase commoning links. Conductor size 8 AWG–1/0.||||||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-168**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Reversing Starters**
|**TPCRB**<br>**TPCRC**<br>**ECM_**<br>**TPCPB**<br>**TPCPD**|**For Use with…**|**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|
|---|---|---|
||XTPR…B + XTCE…B01_|Mechanical connection element for XTPR…B and contactor<br>1<br>**XTPAXTPCRB**<br>Reversing starter main current wiring in toolless plug connection<br>1<br>Control cables for electrical interlocking in toolless plug connection:<br>– K1M: A1–K2M: 21<br>– K1M: 21–K2M: A1<br>– K1M: A2–K2M: A2<br>1<br>Cable guidance<br>1<br>Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables<br>up to 2.5 mm2external diameter or four cables up to 3.5 mm2external diameter.|
||XTPR…B + XTCE…C|DIN rail adapter plate<br>1<br>**XTPAXTPCRC**<br>Reversing starter main current wiring<br>1|
||**Electrical Connection Module**<br>**For Use with…**<br>**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**||
||XTPR…B + XTCE…C<br>Main current wiring between XTPR…B and contactor<br>5<br>**XTPAXECMC**||
||XTPR…D + XTCE…D<br>Main current wiring between XTPR…D and contactor<br>5<br>**XTPAXECMD**||
||**DIN Rail Adapter Plates**<br>**For Use with…**<br>**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**||
||XTPAXTPCB<br>XTPAXTPCRB|45 mm wide adapter plate with one DIN rail<br>4<br>**XTPAXTPCPB**<br>Connection element for side-by-side positioning of further plates|
||XTPAXECMD<br>XTPR…D + XTCE…C<br>XTPR…D + XTCE…D|55 mm wide adapter plate with two DIN rails<br>4<br>**XTPAXTPCPD**<br>Connection cams for further plates<br>For use with reversing and star-delta starters|
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-169**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## _**Pushbutton MMP Enclosures**_
**Insulated Enclosures for Surface Mounting of XTPB Pushbutton Motor-Protective Circuit Breakers—Global Usage**[1]
|**Motor-Protective Circuit Breakers—Global U**|**sage**1|
|---|---|
|**Degree of**<br>**Protection**<br>**For Use**<br>**with…**|**Description**<br>**Catalog Number**|
|IP40<br>NEMA 1<br>XTPB MMP only or with:<br>XTPAXFA_, XTPBXFAEM20,<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXSR_<br>IP65<br>NEMA<br>3R, 4X, 12, 13|—<br>**XTPBXENCS40**|
||With actuation membrane.<br>**XTPBXENCS65**|
|IP65<br>NEMA<br>3R, 4X, 12, 13<br>XTPB MMP only or with:<br>XTPAXFA_, XTPAXUVR_,<br>XTPAXSR_, XTPAXCL|Lockable in OFF position.<br>**XTPBXENCSLO65**|
|IP65<br>NEMA<br>3R, 4X, 12, 13<br>XTPB MMP only or with:<br>XTPAXFA_, XTPBXFAEM20,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>IP65<br>NEMA<br>3R, 4X, 12, 13<br>IP65<br>NEMA<br>3R, 4X, 12, 13|Lockable in OFF position in combination with XTPBXFAEM20<br>early-make front-mount auxiliary contact<br>**XTPBXENCSLE65**|
||With emergency-stop (e-stop) pushbutton actuator, red-yellow<br>**XTPBXENCSES65**|
||With emergency-stop (e-stop) pushbutton actuator, red-yellow<br>key release<br>**XTPBXENCSEK65**|
|**Insulated Enclosures for Surface Mounting of XTPB Pushbutton**<br>**Manual Motor Protectors—North American Usage**23<br>**Degree of**<br>**Protection**<br>**For Use**<br>**with…**<br>**Description**<br>**Catalog Number**||
|IP41<br>NEMA 1<br>XTPB MMP only or with:<br>XTPAXFA_, XTPBXFAEM20,<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXSR_<br>IP65<br>NEMA<br>3R, 4X, 12, 13|—<br>**XTPBXENAS41**|
||With actuating diaphragm<br>**XTPBXENAS65**|
|IP65<br>NEMA<br>3R, 4X, 12, 13<br>XTPB MMP only or with:<br>XTPAXFA_, XTPAXUVR_,<br>XTPAXSR_, XTPAXCL|Lockable in OFF position<br>**XTPBXENASLO65**|
|IP65<br>NEMA<br>3R, 4X, 12, 13<br>XTPB MMP only or with:<br>XTPAXFA_, XTPBXFAEM20,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>IP65<br>NEMA<br>3R, 4X, 12, 13<br>IP65<br>NEMA<br>3R, 4X, 12, 13|Lockable in OFF position in combination with XTPBXFAEM20<br>early-make front-mount auxiliary contact<br>**XTPBXENASLE65**|
||With emergency-stop (e-stop) pushbutton actuator, red-yellow<br>**XTPBXENASES65**|
||With emergency-stop (e-stop) pushbutton actuator, red-yellow<br>key release<br>**XTPBXENASEK65**|
## _**Notes**_
1 Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom.
2 Built-in terminal for PE(N).
- 3 North American enclosures come with conduit adapters for use with 1/2 in NPT.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-170**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**Insulated Enclosures for Surface Mounting of XTPB Pushbutton Manual Motor Protectors—North American Usage**[1]
|**Manual Motor Protectors—North American**|**Usage**1|
|---|---|
|**Degree of**<br>**Protection**<br>**For Use**<br>**with…**|**Description**<br>**Catalog Number**|
|Front IP40<br>NEMA 1<br>XTPB MMP only or with:<br>XTPAXFA_, XTPBXFAEM20,<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXSR_<br>Front IP65<br>NEMA<br>3R, 4X, 12, 13|—<br>**XTPBXENCF40**|
||With actuating diaphragm<br>**XTPBXENCF55**|
|Front IP65<br>NEMA<br>3R, 4X, 12, 13<br>XTPB MMP only or with:<br>XTPAXFA_, XTPAXUVR_,<br>XTPAXSR_, XTPAXCL|Lockable in OFF position<br>**XTPBXENCFLO55**|
|Front IP65<br>NEMA<br>3R, 4X, 12, 13<br>XTPB MMP only or with:<br>XTPAXFA_, XTPBXFAEM20,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>Front IP65<br>NEMA<br>3R, 4X, 12, 13<br>Front IP65<br>NEMA<br>3R, 4X, 12, 13|Lockable in OFF position in combination with XTPBXFAEM20<br>early-make front-mount auxiliary contact<br>**XTPBXENCFLE55**|
||With emergency-stop (e-stop) pushbutton actuator, red-yellow<br>**XTPBXENCFES55**|
||With emergency-stop (e-stop) pushbutton actuator, red-yellow<br>key release<br>**XTPBXENCFEK55**|
## _**Rotary MMP Enclosures**_
**Insulated Enclosures for Surface Mounting of Frame B (0.1–32A) XTPR Motor-Protective Circuit Breakers—Global Usage**
|**Degree of**<br>**Protection**<br>**For Use**<br>**with…**|**Description**<br>**Catalog Number**|
|---|---|
|IP41 with vertical<br>mounting<br>Frame B XTPR only or with:<br>XTPAXFA_, XTPAXSA_,<br>XTPAXSATR_, XTPAXUVR_,<br>XTPAXSR_, XTPAXCL<br>IP65<br>IP65|Cover with aperture dimensioned to accommodate front of<br>MMP. IP40, when mounted turned through 90° to left/right<br>**XTPAXENCS41**1|
||With black/grey rotary handle<br>**XTPAXENCS65B**1|
||With red/yellow rotary handle for use as emergency-stop<br>switches to IEC/EN 60204<br>**XTPAXENCS65RY**1|
|IP40<br>Frame B XTPR only or with:<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXSR_, XTPAXCL|Cover with aperture dimensioned to accommodate front of MMP<br>**XTPAXENCS40**2|
|IP55<br>Frame B XTPR only or with:<br>XTPAXFA_, XTPAXSA_,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>IP55|With black/gray rotary handle<br>**XTPAXENCS55B**2|
||With red/yellow rotary handle for use as emergency-stop<br>switches to IEC/EN 60204<br>**XTPAXENCS55RY**2|
## _**Note**_
1 Integrated terminal for PE(N) connection.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-171**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Insulated Enclosures for Surface Mounting of Frame B (0.1–32A)**
**XTPR Rotary Manual Motor Protectors—North American Usage**[3]
|**XTPR Rotary Manual Motor Protectors—Nor**|**th American Usage**3|
|---|---|
|**Degree of**<br>**Protection**<br>**For Use**<br>**with…**|**Description**<br>**Catalog Number**|
|IP55<br>NEMA 1, 12, 3R<br>Frame B XTPR only or with:<br>XTPAXSA_ and XTPAXFA_,<br>XTPAXUVR_ and XTPAXFA_,<br>XTPAXSR_ and XTPAXFA_,<br>XTPAXCL|With black/gray rotary handle<br>**XTPAXENAS55B**|
||With red/yellow rotary handle for use as emergency-stop<br>switch to VDE 0113<br>**XTPAXENAS55RY**|
**Insulated Enclosures for Surface Mounting of Frame B XTPR (0.1–32A) Rotary Motor-Protective Circuit Breakers with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact—Global Usage**
|**Degree of**<br>**Protection**<br>**For Use**<br>**with…**|**Description**<br>**Catalog Number**|
|---|---|
|IP65<br>Frame B XTPR and XTPAXFAEM20<br>only or with: XTPAXFA_,<br>XTPAXSA_, XTPAXSATR_,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>IP65|With black/gray rotary handle<br>**XTPAXENCSEM65B**|
||With red/yellow rotary handle for use as emergency-stop<br>switches to IEC/EN 60204<br>**XTPAXENCSEM65RY**|
|IP55<br>Frame B XTPR and XTPAXFAEM20<br>only or with: XTPAXFA_,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>IP55|With black/gray rotary handle<br>**XTPAXENCSEM55B**|
||With red/yellow rotary handle for use as emergency-stop<br>switches to IEC/EN 60204<br>**XTPAXENCSEM55RY**|
|**Insulated Enclosures for Surface Mounting of Frame B XTPR (0.1–32A) Rotary Manual Motor Protectors**<br>**with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact—North American Usage**4<br>**Degree of**<br>**Protection**<br>**For Use**<br>**with…**<br>**Description**<br>**Catalog Number**||
|IP55<br>NEMA 1, 12, 3R<br>Frame B XTPR only or with:<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXCL|With black/grey rotary handle<br>**XTPAXENASEM55B**|
||With red/yellow rotary handle for use as emergency-stop<br>switch to VDE 0113<br>**XTPAXENASEM55RY**|
|**Insulated Enclosures for Flush Mounting of Frame B (0.1–32A)**<br>**XTPR Rotary Manual Motor Protectors—Global Usage**5<br>**Degree of**<br>**Protection**<br>**For Use**<br>**with…**<br>**Description**<br>**Catalog Number**||
|Front IP40<br>Frame B XTPR only or with:<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXSR_, XTPAXCL|Cover with aperture dimensioned to accommodate front of MMP<br>**XTPAXENCF40**|
|Front IP55<br>Frame B XTPR only or with:<br>XTPAXSA_, XTPAXUVR_,<br>XTPAXSR_, XTPAXFA_,<br>XTPAXCL|With black/gray rotary handle<br>**XTPAXENCF55B**|
||With red/yellow rotary handle for use as emergency-stop<br>switches to IEC/EN 60204<br>**XTPAXENCF55RY**|
|**Insulated Enclosures for Surface Mounting of Frame D (10–65A)**<br>**Rotary Motor-Protective Circuit Breakers**<br>**Degree of**<br>**Protection**<br>**For Use**<br>**with…**<br>**Description**<br>**Catalog Number**||
|IP65<br>NEMA 1, 12,<br>3R, 4X<br>Frame D XTPR only or with:<br>XTPAXFA_, XTPAXFAEM20,<br>XTPAXSA_, XTPAXSATR_,<br>XTPAXUVR_, XTPAXSR_,<br>XTPAXCL<br>IP65<br>NEMA 1, 12,<br>3R, 4X|With black/gray rotary handle<br>**XTPAXENCSD65B**|
||With red/yellow rotary handle for use as emergency-stop<br>switches to IEC/EN 60204<br>**XTPAXENCSD65RY**|
|**_Notes_**||
- 1 M25 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry. Includes N and PE terminals.
- 2 Integrated terminal for PE(N) connection, two M25 cable entry knockouts at the top and bottom.
- 3 Built-in N and PE terminal, lower part without knockouts.
- 4 Built-in N and PE terminal, lower part without knockouts.
- 5 Integrated terminal for PE(N) connection.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-172**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**MMP Enclosure Accessories**_
|**XTPAXPL_**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|
|---|---|---|---|---|---|---|---|
|**XTPAXPL_**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|**XTPR Manual Motor Protector Enclosure Padlock Attachment**|||
|---|---|---|---|---|
|oe|**For Use**<br>**with…**<br>XTPAXENCS65B, XTPAXENCS65RY,<br>XTPAXENCSEM65B, XTPAXENCSEM65RY,<br>XTPAXENCS55B, XTPAXENCS55RY,<br>XTPAXENCSEM55B, XTPAXENCSEM55RY|**Description**<br>Padlocking feature. Up to three padlocks with 3–6 mm hasp thickness.<br>For use as main switch to IEC/EN 60204|**Pkg.**<br>**Qty.**1<br>3|**Catalog Number**<br>**XTPAXPL1**2|
||XTPAXENCSD65B, XTPAXENCSD65RY<br>XTPAXENCF55B, XTPAXENCF55RY||1<br>3|**XTPAXPL2**2<br>**XTPAXPL3**3|
|**XTPAXNT**|**Neutral Terminal for Use with XTPB and Frame B XTPR Flush-Mount Enclosures**||||
||**For Use**||**Pkg.**||
||**with…**|**Description**|**Qty.**1|**Catalog Number**|
||XTPBXENCF40, XTPBXENCF55, XTPAXENCF40,|For connection of a fifth conductor|20|**XTPAXNT**|
||XTPAXENCF55B, XTPAXENCF55RY||||
## **XTPAXIL_**
## **Indicating Lights with Neon Bulb**[4]
|**Color**|**Description—**<br>**Indicating Light**|**Pkg.**<br>**Qty.**1|**Catalog Number**|
|---|---|---|---|
|White|110–230V|10|**XTPAXILWB**|
||230–400V|10|**XTPAXILWN**|
||415–500V|10|**XTPAXILWC**|
|Green|110–230V|10|**XTPAXILGB**|
||230–400V|10|**XTPAXILGN**|
|Red|415–500V<br>110–230V|10<br>10|**XTPAXILGC**<br>**XTPAXILRB**|
||230–400V|10|**XTPAXILRN**|
For use with XTPR and XTPB enclosures.
Lights do not carry individual IP or NEMA rating. All enclosure ratings remain valid when using indicating lights.
## _**Notes**_
- 1 Orders must be placed in multiples of package quantity listed.
- 2 Lockable in the 0-position of the XTPR manual motor protector.
- 3 Lockable in the OFF position of the Frame B XTPR manual motor protector.
- 4 Product is not UL Listed/Registered.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-173**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Technical Data and Specifications**
_**XT**_ **Manual Motor Protectors**
|**_XT_Manual Motor Protectors**||||||
|---|---|---|---|---|---|
|**Description**<br><br>|**XTPBP16B–**<br>**XTPB025B**||||**XTPRP16B–**<br>**XTPR032B**<br>**XTPR016D–**<br>**XTPR063D**|
|**General**||||||
|Standards<br> <br> <br>|IEC/EN 60947,<br>VDE 0660, UL 508,<br>CSA C22.2 No. 14||||IEC/EN 60947,<br>VDE 0660, UL 508,<br>CSA C22.2 No. 14<br>IEC/EN 60947,<br>VDE 0660, UL 508,<br>CSA C22.2 No. 14|
|Climatic proofing<br>|1||||1<br>1|
|Ambient temperature, °C<br>Storage<br>|–25/80||||–25/80<br>–25/70|
|Open<br>|–25/55||||–25/55<br>–25/55|
|Enclosed<br><br>Mounting position|–25/40<br>90<br>90|||90|–25/40<br>–25/40<br>90<br>90<br>90<br>90<br>90|
|||||||
|||||||
|Direction of incoming supply<br>|As required||||As required<br>As required|
|Degree of protection<br>Device<br>|IP20||||IP20<br>IP20|
|Terminals<br>|IP00||||IP00<br>IP00|
|Protection against direct contact<br> <br>|Finger and<br>back-of-hand proof||||Finger and<br>back-of-hand proof<br>Finger and<br>back-of-hand proof|
|Shock resistance half-sinusoidal shock<br>10 ms to IEC 60068-2-27 (g)<br>|25||||25<br>15|
|Altitude (m), maximum<br>|2000||||2000<br>2000|
|Terminal capacity<br>Solid (mm2)<br> <br>|1 x (1–6)<br>2 x (1–6)||||1 x (1–6)<br>2 x (1–6)<br>1 x (1–50)<br>2 x (1–35)|
|Flexible with ferrule to DIN 46228, (mm2)<br> <br>|1 x (1–6)<br>2 x (1–6)||||1 x (1–6)<br>2 x (1–6)<br>1 x (1–35)<br>2 x (1–35)|
|Solid or stranded (AWG)<br>|18–10||||18–10<br>14–2|
|Terminal screw tightening torque||||||
|Main cable, Nm<br>|1.7||||1.<br>3|
|Main cable, lb-in<br>|15.0||||15.0<br>26.6|
|Control circuit cable, Nm<br>|1||||1<br>1|
|Control circuit cable, lb-in<br>|8.9||||8.9<br>8.9|
|**Main Contacts**||||||
|Rated impulse withstand voltage (Uimp), Vac<br>|6000||||6000<br>6000|
|Overvoltage category/pollution degree<br>|III/3||||III/3<br>III/3|
|Rated operational voltage (Ue), Vac<br>|690||||690<br>690|
|Rated uninterrupted current = rated operational<br>current (Iu= Ie) in amperes<br> <br>|25 or current setting of<br>the overcurrent release||||25 or current setting of<br>the overcurrent release<br>25 or current setting of<br>the overcurrent release|
|Rated frequency, Hz<br>|40–60||||40–60<br>40–60|
|Current heat loss (three-pole at operating temperature), W<br>|6||||6<br>22|
|Lifespan, mechanical (ops)<br>|50,000||||100,000<br>30,000|
|Lifespan, electrical (AC-3 at 400V) (ops)<br>|50,000||||100,000<br>30,000|
|Maximum operating frequency, operations/hr<br>|25||||40<br>40|
|Short-circuit rating||||||
|AC<br>|See**Page V5-T1-179**||||See**Page V5-T1-179**<br>See**Page V5-T1-179**|
|DC (kA)<br>|60||||60 (up to XTPR016B)<br>40 (XTPR020B–XTPR032B)<br>60|
|Motor switching capacity||||||
|AC-3 (up to 690V) in amperes<br>|25||||32<br>65|
|DC-5 (up to 250V) in amperes<br>|25||||25 (3 contacts in series)<br>63 (3 contacts in series)|
## _**Note**_
> 1 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60068-2-30.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-174**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
_**XT**_ **Manual Motor Protectors, continued**
|**_XT_Manual Motor Protectors, continued**||||||
|---|---|---|---|---|---|
||**XTPBP16B–**|**XTPRP16B–**|||**XTPR016D–**|
|**Description**<br>**Releases**|**XTPB025B**|**XTPR032B**|||**XTPR063D**|
|Overload release setting range (x Iu)|0.6–1.0|0.6–1.0|||0.6–1.0|
|Fixed short-circuit release (x Iu)|14|14|||14|
|Short-circuit release tolerance|± 20%|±|20%||± 20%|
|Phase-failure sensitivity|IEC/EN 60947-1-1,<br>VDE 0660 Part 102|IEC/EN 60947-1-1,<br>VDE 0660 Part 102|||IEC/EN 60947-1-1,<br>VDE 0660 Part 102|
|Temperature compensation||||||
|to IEC/EN 60947, VDE 0660, °C|–5/40|–5/40|||–5/40|
|operating range, °C<br>Temperature compensation residual error for T >20°C, %/K|–25/55<br><<br>~~0~~.25|–25/55<br><<br>~~0~~.25|||–25/55<br><<br>~~0~~.25|
|**Auxiliary Contacts**||||||
|**Description**|**XTPAXSA_ _**|**XTPAXFA_ _**||**XTPA(B)XFAEM_ _**|**XTPAXSATR_ _**|
|Rated impulse withstand voltage, Uimp(Vac)|6000|4000||4000|6000|
|Overvoltage category/pollution degree|III/3|III/3||III/3|III/3|
|Rated operational voltage||||||
|Ue(Vac)<br>Ue(Vdc)|500<br>250|440<br>250||440<br>250|500<br>250|
|Safe isolation to VDE 0106 Part 101 and<br>Part 101/A1 between auxiliary contacts|690|690||690|690|
|and main contacts (Vac)<br>Rated operational current||||||
|AC-15||||||
|220–240 V, Ie (A)|3.5|1||1|3.5|
|380–415 V, Ie(A)|2|—||—|2|
|440–500 V, Ie(A)|1|—||—|1|
|DC-13 L/R <100 ms||||||
|24 V, Ie(A)<br>60 V, Ie(A)|2<br>1.5|2<br>—||2<br>—|2<br>1.5|
|110 V, Ie(A)|1|—||—|1|
|220 V, Ie(A)|0.25|—||—|0.25|
|**Lifespan**||||||
|Mechanical, operations (x 106)|0.1|0.1||0.1|0.01|
|Electrical, operations (x 106)|0.05|0.1||0.1|0.005|
|Contact reliability (at Ue= 24 Vdc, Umin–17V,<br>Imin= 5.4 mA, fault probability|<10–8<1 fault<br>at 1 x 108operations|<10–8<1 fault<br>at 1 x 108operations||<10–8<1 fault<br>at 1 x 108operations|<10–8<1 fault<br>at 1 x 108operations|
|Positively driven contacts to ZH 1/457<br>**Short-Circuit Rating without Welding**|Yes|—||—|—|
|Fuseless|FAZ-B4/1-HI|—||—|FAZ-B4/1-HI|
|Fuse (A gG/gL)|10|10||10|10|
|**Terminal Capacity**||||||
|Solid or flexible conductor with ferrule (mm2)|0.75–2.5|0.75–1.5||0.75–1.5|0.75–2.5|
|Solid or stranded (AWG)|18–14|18–16||18–16|18–14|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-175**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Protection of PVC Insulated Cables Against Thermal Overload at Short-Circuit**
## **Undervoltage Release**
|**Description**<br>**XTPAXUVR_**<br>**Cross-Section**<br>Solid or flexible conductor with ferrule (mm2)<br>1 x (0.75–2.5)<br>2 x (0.75–2.5)<br>Solid or stranded (AWG)<br>1 x (18–14)<br>2 x (18–14)<br>**Main Contact**<br>Rated operational voltage, Ue(Vac)<br>42–480<br>Rated operational voltage, Ue(Vdc)<br>24–250<br>Pickup voltage, x Us<br>0.85–1.1<br>Dropout voltage, x Us<br>0.7–0.35<br>**Power Consumption**<br>Pickup AC (VA)<br>5<br>Sealing AC (VA)<br>3|**veoa a ocu**|**veoa a ocu**|**veoa a ocu**|**veoa a ocu**|**veoa a ocu**|**veoa a ocu**|
|---|---|---|---|---|---|---|
||Min. Cross-Section Protected<br>380-415V, 50 Hz, Cu mm2|||||Device<br>Type|
||4|2.5|1.5|1|0.75|XTPRP16BC1<br>...<br>XTPR6P3BC1<br>XTPR010BC1<br>XTPR016BC1<br>XTPR020BC1<br>XTPR025BC1<br>XTPR016DC1<br>XTPR025DC1<br>XTPR032DC1<br>XTPR040DC1<br>XTPR050DC1<br>XTPR058DC1<br>XTPR063DC1|
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
## **Current Limiter**
The chart above indicates which minimum cable cross-sections are protected by XTPR motor protective circuit breakers up to their rated conditional short-circuit current Iq.
|**Current Limiter**||
|---|---|
|**Description**|**XTPAXCL**|
|Rated impulse withstand voltage (Uimp), Vac|6000|
|Overvoltage category/pollution degree|III/3|
|Rated operational voltage, Ue(Vac)<br>Rated interrupted current = Rated operational current (lu= le) in amperes|690<br>63|
## **XTPB, XTPR Single- and Two-Pole Circuits with DC and AC Current**
**==> picture [120 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 3 5 1 3 5<br>I > I > I > I > I > I ><br>2 4 6 2 4 6<br>**----- End of picture text -----**<br>
## **Shunt Release**
|**Shunt Release**||
|---|---|
|**Description**|**XTPAXSR __**|
|**Cross-Section**||
|Solid or flexible conductor with ferrule (mm2)|1 x (0.75–2.5)|
||2 x (0.75–2.5)|
|Solid or stranded (AWG)|1 x (18–14)|
||2 x (18–14)|
|**Main Contact**||
|Rated operational voltage, Ue(Vac)|42–480|
|Rated operational voltage, Ue(Vdc)|24–250|
|AC operating range, x Us|0.7–1.1|
|DC operating range, x Us(intermittent operation 5s)|0.7–1.1|
|**Power Consumption**||
|Pickup AC (VA)|5|
|Sealing AC (VA)|3|
|Pickup DC (VA)|3|
|Sealing DC (VA)|3|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-176**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Wiring Diagrams**
## _**Fuseless Installation with XTPR**_
## **Backup Protection Diagram—XTPR…B**
**==> picture [213 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPR…B 100<br>XTPR...B<br>415 Vac Inherently<br>Back-up short-circuit-proof<br>protection 50<br>range<br>with XTPAXCL<br>30<br>20<br>16<br>Rated<br>short-circuit<br>breaking 10<br>capacity 6<br>range<br>XTPR…B<br>0.16... 101620 25<br>Rated<br>Current<br>n [A]<br>cc rms [kA]<br>XTPR…B + XTPAXCL<br>cn cc<br>XTPR…B<br>Inherently short-circuit proof<br>**----- End of picture text -----**<br>
## **Backup Protection Diagram—XTPR…D**
**==> picture [212 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPR…D 100<br>XTPR...D + XTPAXCL<br>415 Vac<br>Back-up<br>protection 50<br>range with XTPAXCL Rated<br>Current<br>30<br>n [A]<br>20 XTPR…D<br>16<br>Rated<br>short-circuit<br>breaking 10<br>capacity<br>6<br>range<br>XTPR…D<br>16... 25 32 40 50 63<br>Rated<br>Current<br>n [A]<br>cc rms [kA]<br>Inherentlyshort-circuit-proof<br>cn cc<br>Inherently short-circuit proof<br>**----- End of picture text -----**<br>
## **Time/Current Curves**
## _**Characteristics**_
The time/current characteristic, the current limiting characteristics and the I[2] t characteristics were determined in accordance with DIN VDE 0660 and IEC 60 947.
The tripping characteristic of the **inverse-time delayed overload releases** (thermal overload releases or “a” releases) for DC and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic.
The characteristics apply to the cold state. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25%.
Under normal operating conditions, all three-poles of the device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase or DC loads.
With three-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is ±20% and thus in accordance with DIN VDE 0165.
The tripping characteristics for the instantaneous, electromagnetic overcurrent releases (short-circuit releases or “n” releases) are based on the rated current In, which is also the maximum value of the setting range for circuit breakers with adjustable overload releases. If the current is set to a lower value, the tripping current of the “n” release is increased by a corresponding factor.
The characteristics of the electromagnetic overcurrent releases apply to frequencies of 50/60 Hz. Appropriate correction factors must be used for lower frequencies up to 16-2/3 Hz, for higher frequencies up to 400 Hz and for DC.
Time/current characteristics, current limiting characteristics and I[2] t characteristics are available on request.
## _**MMP Tripping Characteristics**_
## **XTPB, XTPR Frame B**
**==> picture [144 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
2h<br>20 XTPB, XTPR Frame B<br>10<br>5<br>2<br>1<br>40<br>20<br>10<br>5<br>2 XTPT<br>1<br>200<br>50<br>20<br>5<br>2<br>1.5 2 3 4 6 8 10 15 20 30<br>x Rated Operational Current<br>Minutes<br>Seconds<br>Milli-seconds<br>**----- End of picture text -----**<br>
## **XTPR Frame D**
**==> picture [144 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
2h<br>20 XTPR Frame D<br>10<br>5<br>2<br>1<br>40<br>20<br>10<br>5<br>2<br>1<br>200<br>50<br>20<br>5<br>2<br>1.5 2 3 4 6 8 10 15 20 30<br>x Rated Operational Current<br>Minutes<br>Seconds<br>Milli-seconds<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-177**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**MMP Let-Through Tripping Characteristics**_ **XTPB, XTPR Frame B**
**==> picture [188 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
32 A<br>I^ D 1086 XTPB XTPR Frame BXTPM 20 A25 A10 A/12 A16 A<br>[kA]<br>4 6.3 A<br>3<br>4.0 A<br>2<br>1<br>0.8 2.5 A<br>0.6<br>0.4 1.6 A<br>0.3<br>0.2 1 A<br>0.1<br>0.08 0.63 A<br>0.06<br>0.04<br>0.03 0.4 A<br>0.02<br>0.015 U e = 400 V 0.25 A<br>0.01<br>1 1.5 2 3 4 6 8 10 15 20 3040 6080100<br>cc rms [[kA]]<br>2 • cc<br>**----- End of picture text -----**<br>
## **XTPR Frame D**
**==> picture [193 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [6]<br>XTPR Frame D<br>i [2] dt<br>[A [2] s]<br>63/58 A<br>50/40/32 A<br>10 [5] 25 A<br>16 A<br>10 [4]<br>10 [3]<br>U e = 400 V<br>10 [2]<br>1 10 100<br>cc rms [[kA]]<br>1st half-wave<br>**----- End of picture text -----**<br>
## **XTPR Frame D**
**==> picture [192 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>I^ D XTPR Frame D<br>[kA]<br>63/58 A<br>50/40/32 A<br>25 A<br>10<br>16 A<br>U e = 400 V<br>1<br>1 10 100<br>cc rms [[kA]]<br>cc<br>2 •<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-178**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Manual Motor Protector Short-Circuit Ratings**_
Rated uninterrupted current Iu = Rated operational current Ie. Rated conditional short-circuit current Iq —IEC/EN 60947-4-1. Rated ultimate short-circuit breaking capacity Icu — IEC/EN 60947-2. Rated operational short-circuit breaking capacity Ics — IEC/EN 60947-2.
## **Global Use, IEC/EN 60947—XTPB with Classification Type “1” and Type “2”**
|**Iu**|**230V**<br>**Iq**|**Icu**|**Ics**|**Fuse**|12|**400V**<br>**Iq**|**Icu**|**Ics**|**Fuse**|12|**440V**<br>**Iq**|**Icu**|**Ics**|**Fuse**|12|**500V**<br>**Iq**|**Icu**|**Ics**|**Fuse**|12|**690V**<br>**Iq**|**Icu**|**Ics**|**Fuse**|12|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**|**kA**|**kA**|**kA**|**A**||**kA**|**kA**|**kA**|**A**||**kA**|**kA**|**kA**|**A**||**kA**|**kA**|**kA**|**A**||**kA**|**kA**|**kA**|**A**||
|0.16–1|50|50|50|50||50|50|50|50||50|50|50|50||—|—|—|—||—|—|—|—||
|1.6|50|50|50|50||50|50|50|50||50|50|50|50||—|—|—|—||—|—|—|—||
|2.5|50|50|50|50||50|50|50|50||50|50|50|50||—|—|—|—||—|—|—|—||
|4|50|50|50|50||50|50|50|50||50|50|50|50||—|—|—|—||—|—|—|—||
|6.3<br>10|50<br>50|50<br>50|50<br>50|50<br>50||50<br>50|50<br>50|50<br>50|50<br>50||50<br>42|50<br>42|50<br>10|50<br>50||—<br>—|—<br>—|—<br>—|—<br>—||—<br>—|—<br>—|—<br>—|—<br>—||
|12|50|50|10|50||50|50|10|50||15|15|10|50||—|—|—|—||—|—|—|—||
|16|50|50|10|50||50|50|10|50||15|15|10|50||—|—|—|—||—|—|—|—||
|20|50|50|10|50||50|50|10|50||10|10|10|50||—|—|—|—||—|—|—|—||
|25|50|50|10|50||50|50|10|50||10|10|10|50||—|—|—|—||—|—|—|—||
## **Global Use, IEC/EN 60947—XTPR…BC1 with Classification Type “1” and Type “2”**
|**Iu**|**230V**<br>**Iq**|**Icu**|**Ics**|**Fuse**12|**400V**<br>**Iq**|**Icu**|**Ics**|**Fuse**12|**440V**<br>**Iq**|**Icu**|**Ics**|**Fuse**12|**500V**<br>**Iq**|**Icu**|**Ics**|**Fuse**12|**690V**<br>**Iq**|**Icu**|**Ics**|**Fuse**12|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|
|0.16–1|1503|1503|1503|N|1503|1503|1503|N|3|3|3|N|3|3|3|N|3|3|3|N|
|1.6|1503|1503|1503|N|1503|1503|1503|N|3|3|3|N|3|3|3|N|3|3|3|N|
|2.5|1503|1503|1503|N|1503|1503|1503|N|3|3|3|N|3|3|3|N|5|5|5|50|
|4|1503|1503|1503|N|1503|1503|1503|N|3|3|3|N|3|3|3|N|3|3|3|50|
|6.3<br>10|1503<br>1503|1503<br>1503|1503<br>1503|N<br>N|1503<br>1503|1503<br>1503|1503<br>1503|N<br>N|3<br>42|3<br>42|3<br>10|N<br>50|42<br>42|42<br>42|6<br>6|50<br>50|3<br>3|3<br>3|2<br>2|50<br>50|
|12|50|50|10|50|50|50|10|50|15|15|10|50|15|15|6|50|3|3|2|50|
|16|50|50|10|50|50|50|10|50|15|15|10|50|15|15|6|50|3|3|2|50|
|20|50|50|10|50|50|50|10|50|15|15|10|50|6|6|6|50|3|3|2|50|
|25|50|50|10|50|50|50|10|50|10|10|10|50|6|6|6|50|3|3|2|50|
|32|50|50|10|50|50|50|10|50|10|10|10|50|6|6|6|50|3|3|2|50|
## _**Notes**_
> 1 N = Not required.
> 2 XTPR…BC1, XTPT, XTPM—Required back-up fuse if the short-circuit current exceeds the rated conditional short-circuit current (Icc > Iq); XTPB, XTPR…DC1—Fuse (A gG/gL) for enhancing the switching capacity of the motor protective circuit breaker to 100 kA.
> 3 No upstream protective device required, as it is the auto-protected range (100/150 kA—Frame B, 150 kA—Frame D).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-179**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Global Use, IEC/EN 60947—XTPR…DC1 with Classification Type “1” and Type “2”**
||**230V**||||**400V**||||**440V**||||**500V**||||**690V**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Iu**|**Iq**|**Icu**|**Ics**|**Fuse**12|**Iq**|**Icu**|**Ics**|**Fuse**12|**Iq**|**Icu**|**Ics**|**Fuse**12|**Iq**|**Icu**|**Ics**|**Fuse**12|**Iq**|**Icu**|**Ics**|**Fuse**12|
|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|**kA**|**kA**|**kA**|**A**|
|16|1503|1503|25|N|1503|1503|25|N|45|45|25|100|15|15||100|8|8|2.5|100|
|25|1503|1503|25|N|1503|1503|25|N|45|45|25|100|15|15||100|8|8|2.5|100|
|32|50|50|25|100|50|50|25|100|45|45|25|100|15|15||100|5|5|2.5|100|
|40<br>50|50<br>50|50<br>50|25<br>25|100<br>100|50<br>50|50<br>50|25<br>25|100<br>100|45<br>45|45<br>45|25<br>25|100<br>100|15<br>15|15<br>15||100<br>100|5<br>5|5<br>5|2.5<br>2.5|100<br>100|
|58|50|50|25|160|50|50|25|160|45|45|25|160|15|15||160|5|5|2.5|160|
|63|50|50|25|160|50|50|25|160|45|45|25|160|15|15||160|5|5|2.5|160|
## _**Ratings for Group Motor Applications**_
**UL 508/CSA C22.2 No. 14—XTPB—Frame B, Manual Motor Protector with Thermal and Magnetic Trip**
|**Catalog Number**<br>**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu (Amps)**<br><br><br> <br><br>|**FLA**<br>**Adjustment**<br>**Range/Overload**<br>**Release—**<br>**Ir (Amps)**<br><br> <br><br>|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Protective Device for UL/CSA Group Protection**<br>**Maximum rms**<br>**Sym Current—**<br>**480V (kA)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**<br>**Maximum Fuse**<br>**Rating (A)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**<br>**Circuit Breaker**<br>**Maximum (A)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**|
|---|---|---|
|**XTPBP16BC1**<br>0.16<br>|0.1–0.16<br>|2.2<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPBP25BC1**<br>0.25<br>|0.16–0.25<br>|3.5<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPBP40BC1**<br>0.4<br>|0.25–0.4<br>|5.6<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPBP63BC1**<br>0.63<br>|0.4–0.63<br>|8.8<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPB001BC1**<br>1<br>|0.63–1<br>|14<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPB1P6BC1**<br>1.6<br>|1–1.6<br>|22<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPB2P5BC1**<br>2.5<br>|1.6–2.5<br>|35<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPB004BC1**<br>4<br>|2.5–4<br>|56<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPB6P3BC1**<br>6.3<br>|4–6.3<br>|88<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPB010BC1**<br>10<br>|6.3–10<br>|140<br>30<br>50<br>600<br>600<br>600<br>600|
|**XTPB012BC1**<br>12<br>|8–12<br>|168<br>10<br>50<br>150<br>600<br>1255<br>600|
|**XTPB016BC1**<br>16<br>|10–16<br>|224<br>10<br>50<br>150<br>600<br>1255<br>600|
|**XTPB020BC1**4<br>20<br>|16–20<br>|280<br>10<br>18<br>150<br>600<br>125<br>600|
|**XTPB025BC1**4<br>25<br>|20–25<br>|350<br>10<br>18<br>150<br>600<br>125<br>600|
## _**Notes**_
> 1 N = Not required.
> 2 XTPR…BC1, XTPT, XTPM—Required back-up fuse if the short-circuit current exceeds the rated conditional short-circuit current (Icc > Iq); XTPB, XTPR…DC1—Fuse (A gG/gL) for enhancing the switching capacity of the motor protective circuit breaker to 100 kA.
- 3 No upstream protective device required, as it is the auto-protected range (100/150 kA—Frame B, 150 kA—Frame D).
- 4 IEC/EN 60947-4-1.
- 5 22 kA 600 Vac.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-180**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**UL 508/CSA C22.2 No. 14—XTPR—Frame B (all Screw and Spring Cage Terminal Options), Manual Motor Protector with Thermal and Magnetic Trip**
|**Catalog Number**<br>**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu (Amps)**<br><br><br> <br><br>|**FLA**<br>**Adjustment**<br>**Range/Overload**<br>**Release—**<br>**Ir (Amps)**<br><br> <br><br>|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Protective Device for UL/CSA Group Protection**<br>**Maximum rms**<br>**Sym Current—**<br>**480V (kA)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**<br>**Maximum Fuse**<br>**Rating (A)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**<br>**Circuit Breaker**<br>**Maximum (A)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**|
|---|---|---|
|**XTPRP16BC1**<br>0.16<br>|0.1–0.16<br>|2.2<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPRP25BC1**<br>0.25<br>|0.16–0.25<br>|3.5<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPRP40BC1**<br>0.4<br>|0.25–0.4<br>|5.6<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPRP63BC1**<br>0.63<br>|0.4–0.63<br>|8.8<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPR001BC1**<br>1<br>|0.63–1<br>|14<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPR1P6BC1**<br>1.6<br>|1–1.6<br>|22<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPR2P5BC1**<br>2.5<br>|1.6–2.5<br>|35<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPR004BC1**<br>4<br>|2.5–4<br>|56<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPR6P3BC1**<br>6.3<br>|4–6.3<br>|88<br>50<br>—<br>600<br>—<br>600<br>—|
|**XTPR010BC1**<br>10<br>|6.3–10<br>|140<br>30<br>50<br>600<br>600<br>600<br>600|
|**XTPR012BC1**<br>12<br>|8–12<br>|168<br>10<br>50<br>150<br>600<br>125<br>600|
|**XTPR016BC1**<br>16<br>|10–16<br>|224<br>10<br>50<br>150<br>600<br>1251<br>600|
|**XTPR032BC1**<br>32<br>|25–32<br>|448<br>10<br>18<br>150<br>600<br>125<br>600|
|**XTPR025BC1**<br>25<br>|20–25<br>|350<br>10<br>18<br>150<br>600<br>125<br>600|
|**XTPR032BC1**<br>32<br>|25–32<br>|448<br>10<br>18<br>150<br>600<br>125<br>600|
## **UL 508/CSA C22.2 No. 14—XTPR—Frame D, Manual Motor Protector with Thermal and Magnetic Trip**
|**Catalog Number**<br>**Rated**<br>**Uninterrupted**<br>**Current—**<br>**Iu (Amps)**<br><br><br> <br><br>|**FLA**<br>**Adjustment**<br>**Range/Overload**<br>**Release—**<br>**Ir (Amps)**<br><br> <br><br>|**Short**<br>**Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Maximum Protective Device for UL/CSA Group Protection**<br>**Maximum rms**<br>**Sym Current—**<br>**480V (kA)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**<br>**Maximum Fuse**<br>**Rating (A)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**<br>**Circuit Breaker**<br>**Maximum (A)**<br>**w/Current**<br>**Limiter—**<br>**XTPAXCL**|
|---|---|---|
|**XTPR016DC1**<br>16<br>|10–16<br>|224<br>65<br>—<br>600<br>—<br>600<br>—|
|**XTPR025DC1**<br>25<br>|16–25<br>|350<br>65<br>—<br>600<br>—<br>600<br>—|
|**XTPR032DC1**<br>32<br>|25–32<br>|448<br>65<br>—<br>600<br>—<br>600<br>—|
|**XTPR040DC1**<br>40<br>|32–40<br>|560<br>65<br>—<br>600<br>—<br>600<br>—|
|**XTPR050DC1**<br>50<br>|40–50<br>|700<br>65<br>—<br>600<br>—<br>600<br>—|
|**XTPR058DC1**<br>58<br>|50–58<br>|812<br>65<br>—<br>600<br>—<br>600<br>—|
|**XTPR063DC1**<br>65<br>|55–63<br>|882<br>65<br>—<br>600<br>—<br>600<br>—|
## _**Note**_
> 1 22 kA 600 Vac.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-181**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **UL 508 Type E Ratings—XTPR Frame B + XTPAXLSA**
|||||**UL 508 Type E Application**|**UL 508 Type E Application**|**Maximum Upstream**||
|---|---|---|---|---|---|---|---|
|**Manual Motor**<br>**Protector—**||**FLA Adjustment**<br>**Range/Overload**|**Short Circuit**|**Maximum rms Symmetrical**<br>**Short-Circuit Ratings (kA)**||**Protective Device (A)**|1<br>**Maximum**|
|**Screw Terminal**|**Line Side Adapter**|**Release—**|**Release—**|||**Maximum Fuse**|**Circuit Breaker**|
|**Catalog Number**|**Catalog Number**|**Ir (Amps)**|**Irm (Amps)**|**480/277V**|**600/347V**|**600V**|**600V**|
|**XTPRP16BB1**|**XTPAXLSA**|0.1–0.16|2.2|50|50|Not required|Not required|
|**XTPRP25BC1**|**XTPAXLSA**|0.16–0.25|3.5|50|50|Not required|Not required|
|**XTPRP40BC1**<br>**XTPRP63BC1**|**XTPAXLSA**<br>**XTPAXLSA**|0.25–0.4<br>0.4–0.63|5.6<br>8.82|50<br>50|50<br>50|Not required<br>Not required|Not required<br>Not required|
|**XTPR001BC1**|**XTPAXLSA**|0.63–1|14|50|50|Not required|Not required|
|**XTPR1P6BC1**|**XTPAXLSA**|1–1.6|22.4|50|50|Not required|Not required|
|**XTPR2P5BC1**|**XTPAXLSA**|1.6–2.5|35|50|50|Not required|Not required|
|**XTPR004BC1**|**XTPAXLSA**|2.5–4|56|50|50|Not required|Not required|
|**XTPR6P3BC1**|**XTPAXLSA**|4–6.3|88.2|65|50|Not required|Not required|
|**XTPR010BC1**<br>**XTPR012BC1**|**XTPAXLSA**<br>**XTPAXLSA**|6.3–10<br>8–12|140<br>168|65<br>65|50<br>—|Not required<br>Not required|Not required<br>Not required|
|**XTPR016BC1**|**XTPAXLSA**|10–16|224|42|—|Not required|Not required|
|**XTPR020BC1**|**XTPAXLSA**|16–20|280|18|—|Not required|Not required|
|**XTPR025BC1**|**XTPAXLSA**|20–25|350|18|—|Not required|Not required|
|**XTPR032BC1**|**XTPAXLSA**|25–32|448|18|—|Not required|Not required|
## **UL 508 Type E Ratings—XTPR Frame D + XTPAXLSAD**
**Maximum Upstream Protective Device (A)**[1]
||||||||**Maximum Upstream**||
|---|---|---|---|---|---|---|---|---|
|**Manual Motor**<br>**Protector—**<br>**Screw Terminal**|**Line Side**<br>**Adapter**|**FLA**<br>**Adjustment**<br>**Range/Overload**<br>**Release—**|**Short**<br>**Circuit**<br>**Release—**|**UL 508 Type E Application**<br>**Maximum rms Symmetrical Short-Circuit Ratings (kA)**|||<br>**Protective Device (A)**1<br>**Maximum Fuse**|**Maximum**<br>**Circuit Breaker**|
|**Catalog Number**|**Catalog Number**|**Ir (Amps)**|**Irm (Amps)**|**240V**|**480/277V**|**600/347V**|**600V**|**600V**|
|**XTPR016DC1**|**XTPAXLSAD**|10–16|224|65|65|25|Not required|Not required|
|**XTPR025DC1**<br>**XTPR032DC1**|**XTPAXLSAD**<br>**XTPAXLSAD**|16–25<br>25–32|350<br>448|65<br>65|65<br>65|25<br>25|Not required<br>Not required|Not required<br>Not required|
|**XTPR040DC1**|**XTPAXLSAD**|32–40|560|65|65|25|Not required|Not required|
|**XTPR050DC1**|**XTPAXLSAD**|40–50|700|65|65|—|Not required|Not required|
|**XTPR058DC1**|**XTPAXLSAD**|50–58|812|65|65|—|Not required|Not required|
|**XTPR063DC1**|**XTPAXLSAD**|55–65|882|65|65|—|Not required|Not required|
_**Note**_
> 1 For UL 508 Type E applications, the manual motor protector assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-182**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Dimensions**
Approximate Dimensions in mm [in]
## **Manual Motor Protectors—XTPB**
## **Manual Motor Protectors, Manual Transformer Protectors—XTPR…B**
**==> picture [480 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
[3.66]93 XTPAXFA [_] XTPAXFA [_] 93 XTPAXFA [_] 45<br>45 [3.66] [1.77]<br>[1.77]<br>45 5.5 44 45 50<br>[1.77] [.22] [1.73] [1.77] [1.97] XTPAXFA [_]<br>74 [2.91] 88 [3.46]<br>85 [3.35] 94 [3.70]<br>**----- End of picture text -----**<br>
## **Manual Motor Protector—XTPR…DC1**
**==> picture [362 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 [.16]<br>65<br>130 XTPAXFA [_] 45 [2.56] 125<br>140 [5.12] [1.77] [4.92]<br>[5.57]<br>30 7.5 [.30] XTPAXFA [_]<br>[1.18]<br>55 [2.17] 118 [4.65]<br>127 [5.00]<br>145 [5.71]<br>171 [6.73]<br>**----- End of picture text -----**<br>
## **Current Limiter—XTPAXCL**
**==> picture [223 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
45<br>[1.77]<br>28<br>[1.10]<br>*<br>90 73 93<br>[3.54] [2.87] [3.66]<br>7.5 44 7.5<br>[.30] [1.73] [.30]<br>49.5 70<br>* IEC/EN 60715 DIN Rail [1.95] [2.76]<br>**----- End of picture text -----**<br>
**MMPs with Early-Make Auxiliary Contacts— XTPR…BC1 + XTPAXFAEM20**
**==> picture [233 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
80 [3.15]<br>XTPAXFAEM20<br>93 45 55<br>[3.66] [1.77] [2.17]<br>45 50 XTPAXFAEM20<br>[1.77] [1.97]<br>68 [2.68]<br>86 [3.39]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-183**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Standard Auxiliary Contact—XTPAXSA_**
**==> picture [171 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
36 45 90<br>[1.42] [1.77] [3.54]<br>9 26<br>[.35] [1.02]<br>68 [2.68]<br>**----- End of picture text -----**<br>
## **Three-Phase Commoning Link—XTPAXCLKB5, XTPAXCLKB4, XTPAXCLKB3 and XTPAXCLKB2**
**==> picture [197 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
261 [10.28] (207 [8.15],<br>153 [6.02], 99 [3.90])<br>27<br>[1.06]<br>54<br>[2.13]<br>Overlapping Mounting<br>to Extend the Three-Phase<br>Commoning Link<br>**----- End of picture text -----**<br>
## **Three-Phase Commoning Link—XTPAXCLKC4, XTPAXCLKC2**
## **Trip Indicating Auxiliary Contact—XTPAXSATR_**
**==> picture [172 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
36 45 90<br>[1.42] [1.77] [3.54]<br>9 26<br>[.35] [1.02]<br>68 [2.68]<br>**----- End of picture text -----**<br>
**==> picture [169 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
234 [9.21] (108 [4.25])<br>27<br>[1.06]<br>63<br>[2.48]<br>**----- End of picture text -----**<br>
## **Incoming Terminal, Line Side Adapter—XTPAXIT, XTPAXLSA**
## **Undervoltage/Shunt Release—XTPAXUVR_, XTPAXSR_**
**==> picture [153 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
36 45 90<br>[1.42] [1.77] [3.54]<br>18 49<br>[.71] [1.93]<br>68 [2.68]<br>**----- End of picture text -----**<br>
**==> picture [123 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
56<br>[2.20]<br>7.5 31<br>[.30] [1.22]<br>XTPAXLSA<br>73<br>[2.87] 48<br>[1.89]<br>41<br>[1.61]<br>XTPAXIT<br>**----- End of picture text -----**<br>
## **Three-Phase Commoning Link—XTPAXCLKA4, XTPAXCLKA2**
**==> picture [140 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
180 [7.09] (90 [3.54])<br>27<br>[1.06]<br>45<br>[1.77]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-184**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## _**Three-Phase Commoning Link**_
## **XTPAXCLKA4D, XTPAXCLKA3D and XTPAXCLKA2D**
## **XTPAXCLKA4D**
**==> picture [229 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>205 [8.07] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
## **XTPAXCLKA3D**
**==> picture [196 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>151 [5.94] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
## **XTPAXCLKC4D and XTPAXCLKC2D**
## **XTPAXCLKC4D**
**==> picture [236 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>260 [10.24] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
## **XTPAXCLKC2D**
**==> picture [157 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>115 [4.53] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
## **XTPAXCLKA2D**
**==> picture [158 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>98 [3.86] 14 33<br>[1.30]<br>[.55]<br>**----- End of picture text -----**<br>
## **XTPAXCLKB4D, XTPAXCLKB3D and XTPAXCLKB2D**
## **XTPAXCLKB4D**
**==> picture [212 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>232 [9.13] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
## **XTPAXCLKB3D**
**==> picture [194 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>170 [6.69] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
## **XTPAXCLKB2D**
**==> picture [163 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
36<br>[1.42]<br>117 [4.6] 14 33<br>[.55] [1.30]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-185**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Insulated Enclosures for Surface Mounting of XTPB Manual Motor Protectors**
**==> picture [154 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
158<br>[6.22]<br>80 [3.15] 116.5 [4.59]<br>**----- End of picture text -----**<br>
**XTPBXENCS40, XTPBXENCS65, XTPBXENAS41, XTPBXENAS65**
**==> picture [187 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
158<br>[6.22]<br>80 [3.15] 116.5 [4.59]<br>177.2 [6.98]<br>**----- End of picture text -----**<br>
**XTPBXENCSEK65, XTPBXENCSES65, XTPBXENASEK65, XTPBXENASES65**
**==> picture [160 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
158<br>[6.22]<br>80 [3.15] 116.5 [4.59]<br>129.5 [5.10]<br>**----- End of picture text -----**<br>
**XTPBXENCSLE65, XTPBXENCSLO65, XTPBXENASLE65, XTPBXENASO065**
## **Insulated Enclosures for Flush Mounting of XTPB Manual Motor Protectors**
**==> picture [505 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
69<br>69 [2.72]<br>[2.72]<br>129<br>129 [5.08]<br>[5.08]<br>90.2 93 [3.66]<br>90.2 93 [3.66] [3.55] 115.2 [4.54]<br>[3.55]<br>115.2 [4.54] 175.9 [6.93]<br>XTPBXENCF40, XTPBXENCF55 XTPBXENCFEK55, XTPBXENCFES55<br>69<br>[2.72]<br>129<br>[5.08]<br>90.2 93 [3.66]<br>[3.55] 115.2 [4.54]<br>XTPBXENCFLE55, XTPBXENCFLO55<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-186**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Insulated Enclosures for Surface Mounting of XTPR…B Manual Motor Protectors**
**==> picture [146 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
158 70<br>[6.22] [2.76]<br>80 [3.15] 90 [3.54]<br>1 00 [3.94]<br>**----- End of picture text -----**<br>
**XTPAXENCS40**
**==> picture [231 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
Drilling Dimensions<br>4.5 [.18]<br>158 153<br>[6.22] [6.02]<br>80 [3.15] 97.5 [3.84] 4.5 8 [.31]<br>125.5 [4.94] [.18]<br>**----- End of picture text -----**<br>
**XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY**
**==> picture [436 x 317] intentionally omitted <==**
**----- Start of picture text -----**<br>
98 [3.86]<br>30 [1.18]<br>SVB-PKZ0-CI 30 Drilling Dimensions<br>44 [1.18] 4.5<br>[1.73] 97.5 [3.84] 28 [.18]<br>[1.10]<br>33<br>[1.30]<br>55 158 153<br>[2.17] [6.22] [6.02]<br>80 [3.15] 4.5<br>[.18] 8<br>XTPAXENCS55_ + XTPAXPL1, XTPAXENCSEM55_ + XTPAXPL1 [.31]<br>Drilling Dimensions<br>M4<br>181 160 181 160 171<br>[7.13] [6.30] [7.13] [6.30] [6.73]<br>100 47.5 100 47.5 M4<br>[3.94] [1.87] [3.94] [1.87]<br>104 1 03 [4.06]<br>[4.09] 130 [5.12]<br>XTPAXENCSH41, XTPAXENCS41, XTPAXENAS41 XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY,<br>XTPAXENAS55B, XTPAXENAS55RY, XTPAXENASEM55B, XTPAXENASEM55RY,<br>XTPAXENCSH65B, XTPAXENCSH65RY, XTPAXENCSEMH65B, XTPAXENCSEMH65RY<br>**----- End of picture text -----**<br>
**==> picture [388 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
98 [3.86]<br>30 [1.18] 30<br>SVB-PKZ0-CI [1.18] Drilling Dimensions<br>44 114 [4.49] 28 M4<br>[1.73] [1.10]<br>33<br>[1.30]<br>181 160 171<br>55 [7.13] [6.30] [6.73]<br>[2.17]<br>97 [3.82] M4<br>**----- End of picture text -----**<br>
**==> picture [174 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPAXENCS65_ + XTPAXPL1, XTPAXENCSEM65_ + XTPAXPL1<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-187**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Insulated Enclosures for Flush Mounting of XTPR…B Manual Motor Protectors**
**==> picture [359 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
69<br>[2.72]<br>4 [.16]<br>129 55 R<br>[5.08] [2.17] 116 – 118<br>[4.57 – 4.64]<br>85 [3.35] 80 [3.15]<br>96 [3.78]<br>70 – 72<br>124 [4.88] [2.76 – 2.83]<br>XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY Mounting Cutout XTPAXENCF_<br>**----- End of picture text -----**<br>
**==> picture [140 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY<br>**----- End of picture text -----**<br>
**==> picture [305 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
98<br>[3.86]<br>30<br>[1.18]<br>30<br>58 [1.18]<br>[2.28]<br>28 [1.10]<br>21<br>55 129 [.83]<br>[2.17] [5.08]<br>80 [3.15] 85<br>96 [3.78] [3.35]<br>124 [4.88]<br>**----- End of picture text -----**<br>
**==> picture [80 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPAXENCF55_ + XTPAXPL3<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-188**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **Insulated Enclosures for Surface Mounting of XTPR…D Manual Motor Protectors**
**==> picture [242 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
240<br>[9.45]<br>160 [6.30] 134 [5.28]<br>181 [7.13]<br>197 [7.76]<br>**----- End of picture text -----**<br>
**XTPAXENCSD65B, XTPAXENCSD65RY**
**==> picture [234 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
98 [3.86]<br>3 [.12]<br>32 [1.26]<br>SVB-PKZ4-CI<br>72<br>[2.83]<br>**----- End of picture text -----**<br>
**XTPAXENCSD65_ + XTPAXPL2**
**==> picture [477 x 198] intentionally omitted <==**
**----- Start of picture text -----**<br>
Drilling Dimensions<br>5.6 [.22]<br>Dia.<br>72<br>[2.83]<br>240 193<br>[9.45] [7.60]<br>160 [6.30] 186 [7.32] 28 [1.10] 142 [5.60]<br>30<br>XTPAXENCSD65 [1.18]<br>**----- End of picture text -----**<br>
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPAXENCSD65<br>**----- End of picture text -----**<br>
## **Rotary Handle Mechanism—XTPAXRHM_**
**==> picture [199 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
43 [1.69] Dia.<br>64 48<br>[2.52] [1.89]<br>64 48<br>[2.52] [1.89]<br>62<br>19.5 [2.44]<br>[.77]<br>Mounting Depth:<br>100 – 240 [3.94 – 9.45]<br>At least 100 [3.94] from the top edge of<br>up to Cover Hinge the mounting rail to the<br>front edge of the panel<br>door/cover<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-189**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
Approximate Dimensions in mm [in]
## _**Pushbutton MMP Enclosures**_
## **Insulated Enclosures for Surface Mounting**
## **Frame B (0.1–32A) XTPR Motor-Protective Circuit Breakers**
## **XTPB Pushbutton MotorProtective Circuit Breakers**
|**Catalog Number**<br>**H x W x D**<br>**Global Usage**<br>**XTPBXENCS40**<br>158 x 80 x 116.5<br>[6.22 x 3.15 x 4.59]<br>**XTPBXENCS65**<br>158 x 80 x 116.5<br>[6.22 x 3.15 x 4.59]<br>**XTPBXENCSLO65**<br>158 x 80 x 129.5<br>[6.22 x 3.15 x 5.10]<br>**XTPBXENCSLE65**<br>158 x 80 x 129.5<br>[6.22 x 3.15 x 5.10]<br>**XTPBXENCSES65**<br>158 x 80 x 177.2<br>[6.22 x 3.15 x 6.98]<br>**XTPBXENCSEK65**<br>158 x 80 x 177.2<br>[6.22 x 3.15 x 6.98]|**Catalog Number**<br>**H x W x D**|
|---|---|
||**Global Usage**|
||**XTPAXENCS41**<br>160 x 100 x 104<br>[6.30 x 3.94 x 4.09]|
||**XTPAXENCS65B**<br>160 x 100 x 130<br>[6.30 x 3.94 x 5.12]|
||**XTPAXENCS65RY**<br>160 x 100 x 130<br>[6.30 x 3.94 x 5.12]|
||**XTPAXENCS40**<br>158 x 80 x 100<br>[6.22 x 3.15 x 3.94]|
||**XTPAXENCS55B**<br>158 x 80 x 125.5<br>[6.22 x 3.15 x 4.94]|
||**XTPAXENCS55RY**<br>158 x 80 x 125.5<br>[6.22 x 3.15 x 4.94]|
## **Frame B (0.1–32A) XTPR Rotary Manual Motor Protectors**
## **XTPB Pushbutton Manual Motor Protectors**
|**XTPB Pushbutton Manual**<br>**Motor Protectors**|**Frame B (0.1–32A) XTPR**<br>**Rotary Manual Motor**<br>**Protectors**|
|---|---|
|**Catalog Number**<br>**H x W x D**<br>**North American Usage**<br>**XTPBXENAS41**<br>158 x 80 x 116.5<br>[6.22 x 3.15 x 4.59]<br>**XTPBXENAS65**<br>158 x 80 x 116.5<br>[6.22 x 3.15 x 4.59]<br>**XTPBXENASLO65**<br>158 x 80 x 129.5<br>[6.22 x 3.15 x 5.10]<br>**XTPBXENASLE65**<br>158 x 80 x 129.5<br>[6.22 x 3.15 x 5.10]<br>**XTPBXENASES65**<br>158 x 80 x 177.2<br>[6.22 x 3.15 x 6.98]<br>**XTPBXENASEK65**<br>158 x 80 x 177.2<br>[6.22 x 3.15 x 6.98]|**Catalog Number**<br>**H x W x D**|
||**North American Usage**|
||**XTPAXENAS55B**<br>160 x 100 x 130<br>[6.30 x 3.94 x 5.12]|
||**XTPAXENAS55RY**<br>160 x 100 x 130<br>[6.30 x 3.94 x 5.12]|
|||
**Frame B XTPR (0.1–32A) Rotary Motor-Protective Circuit Breakers** with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact
|**Catalog Number**|**H x W x D**|
|---|---|
|**Global Usage**||
|**XTPAXENCSEM65B**|160 x 100 x 130|
||[6.30 x 3.94 x 5.12]|
|**XTPAXENCSEM65RY**|160 x 100 x 130|
||[6.30 x 3.94 x 5.12]|
|**XTPAXENCSEM55B**|158 x 80 x 100|
||[6.22 x 3.15 x 3.94]|
|**XTPAXENCSEM55RY**|158 x 80 x 100|
||[6.22 x 3.15 x 3.94]|
**Frame B XTPR (0.1–32A) Rotary Manual Motor Protectors** with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact
**Catalog Number H x W x D North American Usage XTPAXENCSEM55B** 160 x 100 x 130 [6.30 x 3.94 x 5.12] **XTPAXENCSEM55RY** 160 x 100 x 130 [6.30 x 3.94 x 5.12]
**Frame D (10–65A) Rotary Motor-Protective Circuit Breakers**
**Catalog Number H x W x D**
**Global and North American Usage XTPAXENCSD65B** 240 x 160 x 197 [9.45 x 6.30 x 7.76] **XTPAXENCSD65RY** 240 x 160 x 197 [9.45 x 6.30 x 7.76]
## **Insulated Enclosures for**
## **Flush Mounting**
## **XTPB Pushbutton Manual Motor Protectors**
|**Catalog Number**|**H x W x D**|
|---|---|
|**Global and**||
|**North American**|**Usage**|
|**XTPBXENCF40**|129 x 90.2 x 115.2|
||[5.08 x 3.55 x 4.54]|
|**XTPBXENCF55**|129 x 90.2 x 115.2|
||[5.08 x 3.55 x 4.54]|
|**XTPBXENCFLO55**|129 x 90.2 x 115.2|
||[5.08 x 3.55 x 4.54]|
|**XTPBXENCFLE55**|129 x 90.2 x 115.2|
||[5.08 x 3.55 x 4.54]|
|**XTPBXENCFES55**|129 x 90.2 x 175.9|
||[5.08 x 3.55 x 6.93]|
|**XTPBXENCFEK55**|129 x 90.2 x 175.9|
||[5.08 x 3.55 x 6.93]|
**Frame B (0.1–32A) XTPR Rotary Manual Motor Protectors**
|**Protectors**||
|---|---|
|**Catalog Number**|**H x W x D**|
|**Global Usage**||
|**XTPAXENCF40**|129 x 85 x 96|
||[5.08 x 3.35 x 3.78]|
|**XTPAXENCF55B**|129 x 85 x 124|
||[5.08 x 3.35 x 4.88]|
|**XTPAXENCF55RY**|129 x 85 x 124|
||[5.08 x 3.35 x 4.88]|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-190**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Combination Motor Controllers**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .<br>Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**<br>**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .<br>Combination Motor Controllers|**V5-T1-157**|
|Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-192**<br>**V5-T1-193**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-193**<br>**V5-T1-203**|
|Technical Data and Specifications . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-205**<br>**V5-T1-212**|
|An Eaton<br>|||
|Green Solution||
|**_XT_**Electronic Manual Motor Protector . . . . . . . . .|**V5-T1-217**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . . .|**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## **Combination Motor Controllers**
## **Product Description**
Eaton’s _**XT**_ IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by combining motor disconnect function, thermal overload protection, magnetic short-circuit protection and remote control operation in one compact, assembled unit. these assembled manual motor controllers cover motors with FLA ratings from 0.10A to 65A.
The UL 508 Type F or Type E labeled combination motor controller (CMC) includes a line side adapter (LSA). These assembled combination motor controllers cover motors with FLA ratings from 0.10A to 65A.
## **Application Description**
The _**XT**_ IEC non-reversing and reversing manual and combination motor controllers can be used in the following applications:
## _**Group Motor Control**_
Manual motor controllers (MMCs) are ideal for group motor applications where an upstream breaker or fuse provides protection for two or more motors. _**XT**_ manual motor controllers (MMC) combine a manual motor protector, a wiring connector link and IEC contactor.
## _**Individual Branch Circuit for Motor Loads**_
Combination motor controller (CMC), consisting of a line side adapter, manual motor protector, wiring connector link and IEC contactor, provide an efficient means to build an entire branch circuit. The _**XT**_ CMC is UL 508 Type F and Type E approved, meaning it is “self-protected” and doesn’t require the use of an additional fuse or breaker for short circuit protection. This approval means CMC’s can be used in place of a traditional fusestarter and breaker-starter motor circuit.
The manual motor protector was invented in Germany by Moeller to correct this inefficiency. The MMP operates similarly to a circuit breaker, except the inrush (magnetic) protection is set to 14 times the running current, thus accounting for motor start-up current without the necessity to oversize. A overcurrent dial was added to the face of the MMP to serve as the motor overload protection. This “motor protective circuit breaker”, as it is referred to in Europe, now accomplishes all four key functions of a motor branch circuit: disconnect, short circuit, motor controller and motor overload protection. With the addition of a contactor, users have the ability to remotely control the starter device.
Based around two key functional components (MMP and contactor), the CMC is a very cost effective means to build a branch circuit. Fuses and breakers must be oversized to prevent tripping during motor start up, and thus these oversized devices can no longer protect the motor. To compensate for this, a motor overload relay is necessary to protect the motor.
Whether a single motor application or a multiple motor application, CMC’s are an ideal solution for machinery OEMs and panel builders.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-191**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Features**
- ON/OFF rotary handle with lockout provision
- Visible trip indication
- Test trip function
- Motor applications from 0.10A to 65A
- Class 10 overload protection
- Built-in heater and magnetic trip elements to protect the motor
- Phase loss sensitivity
- Type 2 coordination
- Ambient compensated up to 55°C [140°F]
- Control inputs located at front of starter for easy access and wiring
- Wide range of coils
- DIN rail mount— XTSC…BB_
- Mounting plates— XTSC…BC_, XTSC…D motor controllers
- Adjustment dial for setting motor FLA
## **Standards and Certifications**
UL 508 Type F combination motor controller
- IEC Type 2 Approved per IEC 60947-4-1
- UL Listed File No. E245398
- CE Mark
**Note:** For Type 2 Coordination of MMCs, see **Page V5-T1-235** . Protection in different controller types
- UL 508 Type E self-protected combination motor controller
- UL Listed File No. E123500
## **MMC and CMC Applications**
**XTIEC Manual and Combination Motor Controllers Manual Motor Controller UL 508 Type F and Type E**[3] Use in group installation applications. **Combination Motor Controller** Upstream SCPD[1] is required and must Use for single motor branch circuits or be sized smaller than the maximum use multiple CMC’s for a multiple motor upstream SCPD[1] rating on each MMC[2] panel applications. No additional SCPD[1] used. Tap rules should also be observed. is required in the branch, as these devices are “self-protected”. **Line Side Adapter (LSA) Line Side Adapter (LSA)** Not required Type F = Required factory assembled Type E = Factory assembled NOT required **Manual Motor Controller Combination Motor Controller** XTSC/XTSR XTFC/XTFR
## _**Notes**_
Technical Paper AP03402001E.
Line side adapters are not required for non-U.S. applications. Most countries outside of the U.S. classify the MMP as a motor-protective circuit breaker.
- 1 SCPD = Short-circuit protective device (circuit breaker, fuses).
- 2 MMC = Manual motor controller
- 3 Type E self-protected combination controller is the combination of a Type E self-protected device with a contactor.
- Short-circuit trip at 14 times the maximum setting of the FLA adjustment dial
- UL 508 Type F and Type E CMC high fault short-circuit ratings
- 1NO-1NC auxiliary contact as standard on manual motor controller and combination motor controller
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-192**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
## **Combination Motor Controllers**
|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**SC**<br>**SR**<br>**FC**<br>**FR**<br>**_XT_**=<br>**Frame B MMP +**<br>**Frame B Contactor**|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**Product Selection**<br>**_XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations_**<br>**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—**<br>**Maximum UL Ratings**1<br>**XT**<br>**SC**<br>**012**<br>**B**<br>**B**<br>**M**<br>**A**<br>**Type**<br>= Manual motor controller—FVNR<br>= Manual motor controller—FVR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVNR<br>= Combination motor controller, UL 508 Type F<br>and Type E—FVR<br>**Designation**<br>=**_XT_**IEC power control<br>**Frame Size—Contactor**<br>**B**= 45 mm, 7 to 15A<br>**C**= 45 mm, 18 to 32A<br>**D**= 55 mm, 40 to 65A<br>**Rated Current of MMP**<br>**Frame B**<br>**P16**= 0.16A<br>**P25**= 0.25A<br>**P40**= 0.40A<br>**P63**= 0.63A<br>**001**= 1A<br>**1P6**= 1.6A<br>**2P5**= 2.5A<br>**004**= 4A<br>**6P3**= 6.3A<br>**010**= 10A<br>**012**= 12A<br>**016**= 16A<br>**020**= 20A<br>**025**= 25A<br>**032**= 32A<br>**Frame D**<br>**016**= 16A<br>**025**= 25A<br>**032**= 32A<br>**040**= 40A<br>**050**= 50A<br>**058**= 58A<br>**063**= 63A<br>**Frame Size—MMP**<br>**B**= 45 mm, 0.1 to 32A<br>**D**= 55 mm, 16 to 63A<br>**Connector Type**<br>**Blank**= XTPAXTPCB<br>**M**= XTPAXEMCB (only non-reversing)<br>**Frame B MMP +**<br>**Frame B Contactor**<br>~~=~~|**A**<br>**B**<br>**C**<br>**D**<br>**E**<br>**F**<br>**G**<br>**H**<br>**L**<br>**N**<br>**P**<br>**R**<br>**T**<br>**W**<br>**Y**<br>**AD**<br>**BD**<br>**RD**<br>**TD**<br>**WD**|**A**<br>**B**<br>**C**<br>**D**<br>**E**<br>**F**<br>**G**<br>**H**<br>**L**<br>**N**<br>**P**<br>**R**<br>**T**<br>**W**<br>**Y**<br>**AD**<br>**BD**<br>**RD**<br>**TD**<br>**WD**|**Coil Voltage**<br>= 110V 50 Hz, 120V 60 Hz<br>= 220V 50 Hz, 240V 60 Hz<br>= 415V 50 Hz, 480V 60 Hz<br>= 600V 60 Hz<br>= 208V 50 Hz<br>= 230V 50 Hz<br>= 190V 50 Hz, 220V 60 Hz<br>= 240V 50 Hz, 277V 60 Hz<br>= 380V 50 Hz, 440V 60 Hz<br>= 400V 50 Hz<br>= 380V 60 Hz<br>= 12V 50/60 Hz<br>= 24V 50/60 Hz<br>= 42V 50 Hz, 48V 60 Hz<br>= 48V 50 Hz<br>= 120 Vdc<br>= 220 Vdc<br>= 12 Vdc<br>= 24 Vdc<br> = 48 Vdc|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||**FLA Adjustment**|||||||||||||||||||||||||||
||**Range/Overload**|||||||||||||||||||||||||||
||**Release—Ir **<br>**(Amps)**||||**Short-Circuit**||||**Three-Phase**|||||||||||||**Assembled Manual Motor Controller**2||||||
||||||**Release—**<br>**Irm (Amps)**||||**200V**|**240V**||||**480V**|||||**600V**|||**Non-Reversing**<br>**Catalog Number**|||**Catalog Number**3||**Reversing**<br>**Catalog Number**|
|||||||||||||||||||||||||||||
||0.1–0.16||||3.2||||4|4||||1/2|||||1/2|||**XTSCP16BB_**|||||**XTSRP16BB_**|
||0.16–0.25||||3.5||||4|4||||1/2|||||1/2|||**XTSCP25BB_**|||||**XTSRP25BB_**|
||0.25–0.4||||5.6||||4|4||||1/2|||||1/2|||**XTSCP40BB_**|||||**XTSRP40BB_**|
||0.4–0.63||||8.82||||4|4||||1/2|||||1/2|||**XTSCP63BB_**|||||**XTSRP63BB_**|
||0.63–1||||14||||4|4||||1/2|||||1/2|||**XTSC001BB_**|||||**XTSR001BB_**|
||1–1.6||||22.4||||4|4||||3/4|||||1|||**XTSC1P6BB_**|||||**XTSR1P6BB_**|
||1.6–2.5||||35||||1/2|1/2||||1|||||1-1/2|||**XTSC2P5BB_**|||||**XTSR2P5BB_**|
||2.5–4||||56||||1|1||||2|||||3|||**XTSC004BB_**|||||**XTSR004BB_**|
||4–6.3||||88.2||||1-1/2|1-1/2||||3|||||5|||**XTSC6P3BB_**|||||**XTSR6P3BB_**|
||6.3–10||||140||||3|3||||7-1/2|||||7.5|||**XTSC010BB_**|||||**XTSR010BB_**|
||8–12<br>10–16||||168<br>224||||3<br>3|3<br>3||||7-1/2<br>10|||||7.5<br>7.5|||**XTSC012BB_**<br>**XTSC016BB_**|||||**XTSR012BB_**<br>**—**|
## **Product Selection**
## _**XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations**_
**Frame B MMP + Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor— Frame B Contactor Maximum UL Ratings**[1]
## _**Notes**_
- 1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
- 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
- 3 “M” prior to (_) coil suffix will be assembled with standard connector XTPAXEMCB, non-reversing only.
- 4 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-193**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **1 Frame B MMP +Frame B Contactor Factory-Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor—**
**Maximum IEC Ratings**[1]
## **FLA Adjustment**
## **Range/Overload**
## **Release—Ir**
|**Release—Irr **|**Release—Irr **|**Release—Irr **||||||||
|---|---|---|---|---|---|---|---|---|---|
|**(Amps)**<br>~~&~~|||**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**|**Three-Phase**<br>**220–**<br>**240V**|**380–**<br>**415V**|**500V**|**660–**<br>**690V**|**Assembled Manual Motor Controller**<br>**Non-Reversing**<br>**Catalog Number**|**Assembled Manual Motor Controller**2<br>**Reversing**<br>**Catalog Number**|
|0.1–0.16|||3.2|—|—|—|0.06|**XTSCP16BB_**|**XTSRP16BB_**|
|0.16–0.25|||3.5|—|0.06|0.06|0.12|**XTSCP25BB_**|**XTSRP25BB_**|
|0.25–0.4|||5.6|0.06|0.09|0.12|0.18|**XTSCP40BB_**|**XTSRP40BB_**|
|0.4–0.63|||8.82|0.09|0.18|0.25|0.25|**XTSCP63BB_**|**XTSRP63BB_**|
|0.63–1<br>1–1.6|||14<br>22.4|0.12<br>0.25|0.25<br>0.55|0.37<br>0.75|0.55<br>1.1|**XTSC001BB_**<br>**XTSC1P6BB_**|**XTSR001BB_**<br>**XTSR1P6BB_**|
|1.6–2.5|||35|0.37|0.75|1.1|1.5|**XTSC2P5BB_**|**XTSR2P5BB_**|
|2.5–4|||56|0.75|1.5|2.2|3|**XTSC004BB_**|**XTSR004BB_**|
|4–6.3|||88.2|1.1|2.2|3|4|**XTSC6P3BB_**|**XTSR6P3BB_**|
|6.3–10|||140|2.2|4|4|7.5|**XTSC010BB_**|**XTSR010BB_**|
|8–12|||168|3|5.5|5.5|11|**XTSC012BB_**|**XTSR012BB_**|
|10–16|||224|4|7.5|9|12.5|**XTSC016BB_**|**—**|
## **Frame B MMP + Frame C Contactor**
## **Factory-Assembled Manual Motor**
**Controller—Frame B MMP + Frame C Contactor— Maximum UL Ratings**[1]
|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**|||||||||||
|**Range/Overload**|||||||||||
|**Release—Ir **<br>**(Amps)**||||**Short-Circuit**|||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|||||**Release—**<br>**Irm (Amps)**|**Three-Phase**<br>**200V**|**240V**|**480V**|**600V**|**Non-Reversing**<br>**Catalog Number**|**Reversing**<br>**Catalog Number**|
||||||||||||
|10–16||||224|3|3|10|10|**XTSC016BC_**|**XTSR016BC_**|
|16–20||||280|5|5|10|15|**XTSC020BC_**|**XTSR020BC_**|
|20–25||||350|5|7-1/2|15|20|**XTSC025BC_**|**XTSR025BC_**|
|25–32||||448|7-1/2|10|20|25|**XTSC032BC_**|**XTSR032BC_**|
**Frame B MMP + Frame C Contactor**
**Factory-Assembled Manual Motor Controller—Frame B MMP + Frame C Contactor— Maximum IEC RatingS**[1]
**FLA Adjustment Range/Overload Release—Ir**
|**Release—Irr **|**Release—Irr **|**Release—Irr **|**Release—Irr **|**Release—Irr **|**Release—Irr **|**Release—Irr **|**Release—Irr **|
|---|---|---|---|---|---|---|---|
|**(Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**<br>10–16<br>224<br>4<br>7.5<br>9<br>12.5<br>**XTSC016BC_**<br>**XTSR016BC_**<br>~~ce~~||||||||
|16–20|280|5.5|9|12.5|15|**XTSC020BC_**|**XTSR020BC_**|
|20–25|350|5.5|11|15|22|**XTSC025BC_**|**XTSR025BC_**|
|25–32|448|7.5|15|22|30|**XTSC032BC_**|**XTSR032BC_**|
## _**Notes**_
- 1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
- 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-194**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Frame D MMP + Frame C Contactor**
**Factory-Assembled Manual Motor Controller—Frame D MMP + Frame C Contactor— Maximum UL Ratings**[1]
|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**<br>**Range/Overload**|||||||||||
|**Release—Ir **|||||||||||
|**(Amps)**||||**Short-Circuit**|||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|||||**Release—**<br>**Irm (Amps)**|**Three-Phase**<br>**200V**|**240V**|**480V**|**600V**|**Non-Reversing**<br>**Catalog Number**|**Reversing**<br>**Catalog Number**|
||||||||||||
|10–16||||224|3|5|10|15|**XTSC016DC_**|**XTSR016DC_**|
|16–25||||350|5|7-1/2|15|20|**XTSC025DC_**|**XTSR025DC_**|
|25–32||||448|7-1/2|10|20|30|**XTSC032DC_**|**XTSR032DC_**|
## **Frame D MMP + Frame C Contactor**
**Factory-Assembled Manual Motor Controller—Frame D MMP + Frame C Contactor— Maximum IEC Ratings**[1]
|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**|||||||||||
|**Range/Overload**|||||||||||
|**Release—Ir **<br>**(Amps)**||||**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**|**Three-Phase**<br>**220–**<br>**240V**|**380–**<br>**415V**|**500V**|**660–**<br>**690V**|**Assembled Manual Motor Controller**<br>**Non-Reversing**<br>**Catalog Number**|**Assembled Manual Motor Controller**2<br>**Reversing**<br>**Catalog Number**|
||||||||||||
|10–16||||224|4|7.5|9|12.5|**XTSC016DC_**|**XTSR016DC_**|
|16–25||||350|5.5|12.5|12.5|22|**XTSC025DC_**|**XTSR025DC_**|
|25–32||||448|7.5|15|17.5|22|**XTSC032DC_**|**XTSR032DC_**|
## **Frame D MMP + Frame D Contactor**
**Factory-Assembled Manual Motor Controller—Frame D MMP + Frame D Contactor— Maximum UL Ratings**[1]
|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**<br>**Range/Overload**|||||||||||
|**Release—Ir **|||||||||||
|**(Amps)**||||**Short-Circuit**|||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|||||**Release—**<br>**Irm (Amps)**|**Three-Phase**<br>**200V**|**240V**|**480V**|**600V**|**Non-Reversing**<br>**Catalog Number**|**Reversing**<br>**Catalog Number**|
||||||||||||
|32–40||||560|10|15|30|30|**XTSC040DD_**|**XTSR040DD_**|
|40–50||||700|15|15|30|—|**XTSC050DD_**|**XTSR050DD_**|
|50–58<br>55–65||||812<br>882|15<br>15|15<br>15|40<br>40|—<br>—|**XTSC058DD_**<br>**XTSC063DD_**|**XTSR058DD_**<br>**XTSR063DD_**|
## _**Notes**_
1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
> 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-195**
1.1
_**XT**_ IEC Power Control
## IEC Contactors and Starters
## **1 Frame D MMP +Frame D Contactor Factory-Assembled Manual Motor Controller—Frame D MMP + Frame D Contactor—Maximum IEC Ratings**[1]
|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**<br>**Range/Overload**|||||||||||
|**Release—Ir **|||||||||||
|**(Amps)**||||**Short-Circuit**|**Three-Phase**||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|||||**Release—**<br>**Irm (Amps)**|**220–**<br>**240V**|**380–**<br>**415V**|**500V**|**660–**<br>**690V**|**Non-Reversing**<br>**Catalog Number**|**Reversing**<br>**Catalog Number**|
||||||||||||
|32–40||||560|11|20|22|30|**XTSC040DD_**|**XTSR040DD_**|
|40–50||||700|14|25|30|45|**XTSC050DD_**|**XTSR050DD_**|
|50–58<br>55–65||||812<br>882|17<br>18.5|30<br>34|37<br>37|55<br>55|**XTSC058DD_**<br>**XTSC063DD_**|**XTSR058DD_**<br>**XTSR063DD_**|
## **AC and DC Coil Suffixes**
|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|**Coil Voltage**|**Suffix Code**|
|---|---|---|---|---|---|---|---|
|**Frame B Contactors**||||**Frame C and D Contactors**||||
|110V 50 Hz, 120V 60 Hz|**A**|380V 50 Hz, 440V 60 Hz|**L**|110V 50 Hz, 120V 60 Hz|**A**|380V 50 Hz, 440V 60 Hz|**L**|
|220V 50 Hz, 240V 60 Hz|**B**|400V 50 Hz|**N**|220V 50 Hz, 240V 60 Hz|**B**|400V 50 Hz|**N**|
|230V 50 Hz|**F**|380V 60 Hz|**P**|230V 50 Hz|**F**|380V 60 Hz|**P**|
|24V 50/60 Hz|**T**|12V 50/60 Hz|**R**|24V 50/60 Hz|**T**|12V 50/60 Hz|**R**|
|24 Vdc|**TD** 3|42V 50 Hz, 48V 60 Hz|**W**|24–27 Vdc|**TD** 3|42V 50 Hz, 48V 60 Hz|**W**|
|415V 50 Hz, 480V 60 Hz|**C**|48V 50 Hz|**Y**|415V 50 Hz, 480V 60 Hz|**C**|48V 50 Hz|**Y**|
|600V 60 Hz<br>208V 60 Hz|**D**<br>**E**|120 Vdc<br>220 Vdc|**AD** 3<br>**BD** 3|550V 50 Hz, 600V 60 Hz<br>208V 60 Hz|**D**<br>**E**|110–130 Vdc<br>200–240 Vdc|**AD** 3<br>**BD** 3|
|190V 50 Hz, 220V 60 Hz|**G**|12 Vdc|**RD** 3|190V 50 Hz, 220V 60 Hz|**G**|12–14 Vdc|**RD** 3|
|240V 50 Hz, 277V 60 Hz|**H**|48 Vdc|**WD** 3|240V 50 Hz, 277V 60 Hz|**H**|48–60 Vdc|**WD** 3|
## _**Notes**_
The assembled manual motor controller (MMC) consists of an XTPR manual motor protector (MMP) and an XTCE contactor. For Frame B MMP + Frame B contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For MMCs using a Frame C or Frame D contactor, the assembly is mounted via a DIN rail adapter plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules (XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor: SF = 1.15 → Ir = 1 x In mot
SF = 1 → Ir = 0.9 x In mot
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
> 1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
> 2 Underscore (_) indicates magnetic coil suffix required. See AC and DC coil suffixes above.
> 3 With DC operation: Integrated diode-resistor combination, coil rating 2.6W.
**Non-Reversing Manual Motor Controller Power Circuit**
**Non-Reversing Manual Reversing Manual Motor Controller Power Motor Controller Power Circuit Circuit** ~~ey~~ | ~~co @~~ ie ~~|~~ r ~~er pot)~~ M M 3 ~ 3 ~ ~~L~~ a yo!
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-196**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F**_
**Frame B MMP + Two Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame B Contactor— Frame B Contactors Maximum UL Ratings**[1]
|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**||||||||||
|**Range/Overload**<br>**Release—Ir **<br>**(Amps)**|||**Short-Circuit**|**Three-Phase**||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|0.16–0.25|||**Release—**<br>**Irm (Amps)**<br>3.5|**200V**<br>3|**240V**<br>3|**480V**<br>1/2|**600V**<br>1/2|**Non-Reversing**<br>**Catalog Number**<br>**XTFCP25BB_**|**Reversing**<br>**Catalog Number**<br>**XTFRP25BB_**|
|0.25–0.4|||5.6|3|3|1/2|1/2|**XTFCP40BB_**|**XTFRP40BB_**|
|0.4–0.63|||8.82|3|3|1/2|1/2|**XTFCP63BB_**|**XTFRP63BB_**|
|0.63–1|||14|3|3|1/2|1/2|**XTFC001BB_**|**XTFR001BB_**|
|1–1.6<br>1.6–2.5|||22.4<br>35|3<br>1/2|3<br>1/2|3/4<br>1|1<br>1-1/2|**XTFC1P6BB_**<br>**XTFC2P5BB_**|**XTFR1P6BB_**<br>**XTFR2P5BB_**|
|2.5–4|||56|1|1|2|3|**XTFC004BB_**|**XTFR004BB_**|
|4–6.3|||88.2|1-1/2|1-1/2|3|5|**XTFC6P3BB_**|**XTFR6P3BB_**|
|6.3–10|||140|3|3|7-1/2|7.5|**XTFC010BB_**|**XTFR010BB_**|
|8–12|||168|3|3|7-1/2|—|**XTFC012BB_**|**XTFR012BB_**|
|10–16|||224|3|5|10|—|**XTFC016BB_**|**—**|
**Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame B Contactor— Maximum IEC Ratings**[1]
**FLA Adjustment**
|**FLA Adjustment**|**FLA Adjustment**|**FLA Adjustment**||||||||
|---|---|---|---|---|---|---|---|---|---|
|**Range/Overload**||||||||||
|**Release—Ir **<br>**(Amps)**|||**Short-Circuit**|**Three-Phase**||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|**Release—**<br>**Irm (Amps)**<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**<br>~~St~~||||||||||
|0.1–0.16|||2.2|—|—|—|0.06|**XTFCP16BB_**|**XTFRP16BB_**|
|0.16–0.25|||3.5|—|0.06|0.06|0.12|**XTFCP25BB_**|**XTFRP25BB_**|
|0.25–0.4|||5.6|0.06|0.09|0.12|0.18|**XTFCP40BB_**|**XTFRP40BB_**|
|0.4–0.63|||8.82|0.09|0.18|0.25|0.25|**XTFCP63BB_**|**XTFRP63BB_**|
|0.63–1<br>1–1.6|||14<br>22.4|0.12<br>0.25|0.25<br>0.55|0.37<br>0.75|0.55<br>1.1|**XTFC001BB_**<br>**XTFC1P6BB_**|**XTFR001BB_**<br>**XTFR1P6BB_**|
|1.6–2.5|||35|0.37|0.75|1.1|1.5|**XTFC2P5BB_**|**XTFR2P5BB_**|
|2.5–4|||56|0.75|1.5|2.2|3|**XTFC004BB_**|**XTFR004BB_**|
|4–6.3|||88.2|1.1|2.2|3|4|**XTFC6P3BB_**|**XTFR6P3BB_**|
|6.3–10<br>8–12|||140<br>168|2.2<br>3|4<br>5.5|4<br>5.5|7.5<br>11|**XTFC010BB_**<br>**XTFC012BB_**|**XTFR010BB_**<br>**XTFR012BB_**|
|10–16|||224|4|7.5|9|12.5|**XTFC016BB_**|**—**|
## _**Notes**_
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
> 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
- 3 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-197**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
**Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame C Contactor— Maximum UL Ratings**[1]
|**Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame C Contactor—**<br>**Maximum UL Ratings**1|**Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame C Contactor—**<br>**Maximum UL Ratings**1|
|---|---|
|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2||
|||
|||
|||
|10–16<br>224<br>3<br>5<br>10<br>—<br>**XTFC016BC_**<br>**XTFR016BC_**||
|16–20<br>280<br>5<br>5<br>—<br>—<br>**XTFC020BC_**<br>**XTFR020BC_**||
|20–25<br>350<br>5<br>7-1/2<br>15<br>—<br>**XTFC025BC_**<br>**XTFR025BC_**||
|25–32<br>448<br>7-1/2<br>10<br>20<br>—<br>**XTFC032BC_**<br>**XTFR032BC_**||
**Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame C Contactor— Maximum IEC Ratings**[1]
|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**|
|---|---|
|||
|||
|||
|10–16<br>224<br>4<br>7.5<br>9<br>12.5<br>**XTFC016BC_**<br>**XTFR016BC_**||
|16–20<br>280<br>5.5<br>9<br>12.5<br>15<br>**XTFC020BC_**<br>**XTFR020BC_**||
|20–25<br>350<br>5.5<br>11<br>15<br>22<br>**XTFC025BC_**<br>**XTFR025BC_**||
|25–32<br>448<br>7.5<br>15<br>22<br>30<br>**XTFC032BC_**<br>**XTFR032BC_**||
**Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame C Contactor— Maximum UL Ratings**[1]
|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2|
|---|---|
|||
|||
|||
|10–16<br>224<br>3<br>5<br>10<br>10<br>**XTFC016DC_**<br>**XTFR016DC_**||
|16–25<br>350<br>5<br>7-1/2<br>15<br>20<br>**XTFC025DC_**<br>**XTFR025DC_**||
|25–32<br>448<br>7-1/2<br>10<br>25<br>30<br>**XTFC032DC_**<br>**XTFR032DC_**||
**Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame C Contactor— Maximum IEC Ratings**[1]
|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**|
|---|---|
|||
|||
|||
|10–16<br>224<br>4<br>7.5<br>9<br>12.5<br>**XTFC016DC_**<br>**XTFR016DC_**||
|16–25<br>350<br>5.5<br>12.5<br>12.5<br>22<br>**XTFC025DC_**<br>**XTFR025DC_**||
|25–32<br>448<br>7.5<br>15<br>17.5<br>22<br>**XTFC032DC_**<br>**XTFR032DC_**||
## _**Notes**_
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
- 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-198**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame D Contactor— Maximum UL Ratings**[1]
|**Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame D Contactor—**<br>**Maximum UL Ratings**1|**Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame D Contactor—**<br>**Maximum UL Ratings**1|
|---|---|
|**FLA Adjustment**<br>**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**200V**<br>**240V**<br>**480V**<br>**600V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**||
|||
|||
|||
|32–40<br>560<br>10<br>15<br>30<br>30<br>**XTFC040DD_**<br>**XTFR040DD_**||
|40–50<br>700<br>10<br>15<br>30<br>—<br>**XTFC050DD_**<br>**XTFR050DD_**||
|50–58<br>812<br>15<br>15<br>40<br>—<br>**XTFC058DD_**<br>**XTFR058DD_**||
|55–65<br>882<br>15<br>15<br>40<br>—<br>**XTFC063DD_**<br>**XTFR063DD_**||
**Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame D Contactor— Maximum IEC Ratings**[1]
## **FLA Adjustment**
|**FLA Adjustment**|**FLA Adjustment**|
|---|---|
|**Range/Overload**<br>**Release—Ir (Amps)**<br>**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**<br>**Three-Phase**<br>**Assembled Manual Motor Controller**2<br>**220–**<br>**240V**<br>**380–**<br>**415V**<br>**500V**<br>**660–**<br>**690V**<br>**Non-Reversing**<br>**Catalog Number**<br>**Reversing**<br>**Catalog Number**||
|||
|||
|||
|32–40<br>560<br>11<br>20<br>22<br>30<br>**XTFC040DD_**<br>**XTFR040DD_**||
|40–50<br>700<br>14<br>25<br>30<br>45<br>**XTFC050DD_**<br>**XTFR050DD_**||
|50–58<br>812<br>17<br>30<br>37<br>55<br>**XTFC058DD_**<br>**XTFR058DD_**||
|55–65<br>882<br>18.5<br>34<br>37<br>55<br>**XTFC063DD_**<br>**XTFR063DD_**||
## _**Notes**_
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
> 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-199**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type E**_
## **Frame B MMP + Two Frame B Contactors**
**Factory-Assembled Type E Combination Motor Controller—Frame B MMP + Frame B Contactor— Maximum UL Ratings**[1]
|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**|**Maximum UL Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**||||||||||
|**Range/Overload**<br>**Release—Ir **<br>**(Amps)**|||**Short-Circuit**|**Three-Phase**||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|0.16–0.25|||**Release—**<br>**Irm (Amps)**<br>3.5|**200V**<br>3|**240V**<br>3|**480V**<br>1/2|**600V**<br>1/2|**Non-Reversing**<br>**Catalog Number**<br>**XTFCP25BB_**|**Reversing**<br>**Catalog Number**<br>**XTFRP25BB_**|
|0.25–0.4|||5.6|3|3|1/2|1/2|**XTFCP40BB_**|**XTFRP40BB_**|
|0.4–0.63|||8.82|3|3|1/2|1/2|**XTFCP63BB_**|**XTFRP63BB_**|
|0.63–1|||14|3|3|1/2|1/2|**XTFC001BB_**|**XTFR001BB_**|
|1–1.6<br>1.6–2.5|||22.4<br>35|3<br>1/2|3<br>1/2|3/4<br>1|1<br>1-1/2|**XTFC1P6BB_**<br>**XTFC2P5BB_**|**XTFR1P6BB_**<br>**XTFR2P5BB_**|
|2.5–4|||56|1|1|2|3|**XTFC004BB_**|**XTFR004BB_**|
**Factory-Assembled Type E Combination Motor Controller—Frame B MMP + Frame B Contactor— Maximum IEC Ratings**[1]
|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**|**Maximum IEC Ratings**[1]|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**FLA Adjustment**|||||||||||
|**Range/Overload**<br>**Release—Ir **<br>**(Amps)**|||||**Three-Phase**||||**Assembled Manual Motor Controller**|**Assembled Manual Motor Controller**2|
|||||**Short-Circuit**<br>**Release—**<br>**Irm (Amps)**|**220–**<br>**240V**|**380–**<br>**415V**|**500V**|**660–**<br>**690V**|**Non-Reversing**<br>**Catalog Number**|**Reversing**<br>**Catalog Number**|
||||||||||||
|0.1–0.16||||2.2|—|—|—|0.06|**XTFCP16BB_**|**XTFRP16BB_**|
|0.16–0.25<br>0.25–0.4||||3.5<br>5.6|—<br>0.06|0.06<br>0.09|0.06<br>0.12|0.12<br>0.18|**XTFCP25BB_**<br>**XTFCP40BB_**|**XTFRP25BB_**<br>**XTFRP40BB_**|
|0.4–0.63||||8.82|0.09|0.18|0.25|0.25|**XTFCP63BB_**|**XTFRP63BB_**|
|0.63–1||||14|0.12|0.25|0.37|0.55|**XTFC001BB_**|**XTFR001BB_**|
|1–1.6||||22.4|0.25|0.55|0.75|1.1|**XTFC1P6BB_**|**XTFR1P6BB_**|
|1.6–2.5||||35|0.37|0.75|1.1|1.5|**XTFC2P5BB_**|**XTFR2P5BB_**|
|2.5–4||||56|0.75|1.5|2.2|3|**XTFC004BB_**|**XTFR004BB_**|
## _**Notes**_
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
- 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-200**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**Factory-Assembled Type E Combination Motor Controller—Frame B MMP + Frame C Contactor— Maximum UL Ratings**[1]
|**Maximum U**|**L Ratings**1|||||||
|---|---|---|---|---|---|---|---|
||**Short-Circuit**<br>**Release—**|**Max. Motor hp Rating**1||||**Compact 2 Component**|**Combination Motor Controller**|
|**FLA Adjustment**|**Irm (Amps)**|**200V**|**230V**|**460V**|**575V**|**Catalog Number**2|**Catalog Number**2|
|4–6.3|88.2|1.5|1.5|3.0|50|**XTFC6P3BC_**|**XTFR6P3BC_**|
|6.3–10<br>8–12|140<br>168|3.0<br>3.0|3.0<br>3.0|7.5<br>7.5|7.5<br>—|**XTFC010BC_**<br>**XTFC012BC_**|**XTFR010BC_**<br>**XTFR012BC_**|
|10–16|224|3.0|5.0|10.0|—|**XTFC016BC_**|**XTFR016BC_**|
**Factory-Assembled Type E Combination Motor Controller—Frame B MMP + Frame C Contactor— Maximum IEC Ratings**[1]
|**Maximum IE**|**C Ratings**1|||||||
|---|---|---|---|---|---|---|---|
||**Short-Circuit**|**Max. Motor kW Rating**1||||**Compact 2 Component**|**Combination Motor Controller**|
|**FLA Adjustment**|**Release—**<br>**Irm (Amps)**|**200V**|**230V**|**460V**|**575V**|**Catalog Number**2|**Catalog Number**2|
|4–6.3<br>6.3–10|88.2<br>140|1.1<br>2.2|2.2<br>4.0|3.0<br>4.0|4.0<br>7.5|**XTFC6P3BC_**<br>**XTFC010BC_**|**XTFR6P3BC_**<br>**XTFR010BC_**|
|8–12|168|3.0|5.5|5.5|11.0|**XTFC012BC_**|**XTFR012BC_**|
|10–16|224|4.0|7.5|9.0|12.5|**XTFC016BC_**|**XTFR016BC_**|
**Factory-Assembled Type E Combination Motor Controller—Frame D MMP + Frame D Contactor— Maximum UL Ratings**[1]
|**Maximum U**|**L Ratings**1|||||||
|---|---|---|---|---|---|---|---|
||**Short-Circuit**<br>**Release—**|**Max. Motor hp Rating**1||||**Compact 2 Component**|**Combination Motor Controller**|
|**FLA Adjustment**<br>10–16|**Irm (Amps)**<br>224|**200V**<br>3.0|**230V**<br>5.0|**460V**<br>10.0|**575V**<br>10.0|**Catalog Number**2<br>**XTFC016DD_**|**Catalog Number**2<br>**XTFR016DD_**|
|16–25|350|5.0|7.5|15.0|20.0|**XTFC025DD_**|**XTFR025DD_**|
|25–32|448|7.5|10.0|25.0|20.0|**XTFC032DD_**|**XTFR032DD_**|
|32–40|560|11.0|20.0|22.0|30.0|**XTFC040DD_**|**XTFR040DD_**|
|40–50|700|14.0|25.0|30.0|45.0|**XTFC050DD_**|**XTFR050DD_**|
|50–58|812|17.0|30.0|37.0|55.0|**XTFC058DD_**|**XTFR058DD_**|
**Factory-Assembled Type E Combination Motor Controller—Frame D MMP + Frame D Contactor— Maximum IEC Ratings**[1]
|**Maximum IE**|**C Ratings**1|||||||
|---|---|---|---|---|---|---|---|
||**Short-Circuit**<br>**Release—**|**Max. Motor kW Rating**1||||**Compact 2 Component**|**Combination Motor Controller**|
|**FLA Adjustment**|**Irm (Amps)**|**200V**|**230V**|**460V**|**575V**|**Catalog Number**2|**Catalog Number**2|
|10–16|224|4.0|7.5|9.0|12.5|**XTFC016DD_**|**XTFR016DD_**|
|16–25<br>25–32|350<br>448|5.5<br>7.5|12.5<br>15.0|12.5<br>17.5|22.0<br>22.0|**XTFC025DD_**<br>**XTFC032DD_**|**XTFR025DD_**<br>**XTFR032DD_**|
|32–40|560|10.0|15.0|30.0|30.0|**XTFC040DD_**|**XTFR040DD_**|
|40–50|700|10.0|15.0|30.0|—|**XTFC050DD_**|**XTFR050DD_**|
|50–58|812|15.0|15.0|40.0|—|**XTFC058DD_**|**XTFR058DD_**|
## _**Notes**_
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
> 2 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
3 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-201**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
## **AC and DC Coil Suffixes**
|**AC and DC Coil Suffixes**||||
|---|---|---|---|
|**Coil Voltage**<br>**Suffix Code**<br>**Frame B Contactors**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24 Vdc<br>**TD** 1<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br>|**Coil Voltage**<br>**Suffix Code**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>120 Vdc<br>**AD** 1<br>220 Vdc<br>**BD** 1<br>12 Vdc<br>**RD** 1<br>48 Vdc<br>**WD** 1|**Coil Voltage**<br>**Suffix Code**<br>**Frame C and D Contactors**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD** 1<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>550V 50 Hz, 600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**|**Coil Voltage**<br>**Suffix Code**|
|||||
||||380V 50 Hz, 440V 60 Hz<br>**L**|
||||400V 50 Hz<br>**N**|
||||380V 60 Hz<br>**P**|
||||12V 50/60 Hz<br>**R**|
||||42V 50 Hz, 48V 60 Hz<br>**W**|
||||48V 50 Hz<br>**Y**|
||||110–130 Vdc<br>**AD** 1|
||||200–240 Vdc<br>**BD** 1|
||||12–14 Vdc<br>**RD** 1|
||||48–60 Vdc<br>**WD** 1|
## _**Notes**_
The assembled manual motor controller (MMC) consists of an XTPR manual motor protector (MMP) and an XTCE contactor. For Frame B MMP + Frame B contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For 16A and above, the assembly is mounted via a DIN rail adapter plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules (XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor: SF = 1.15 → Ir = 1 x In mot SF = 1 → Ir = 0.9 x In mot
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
> 1 With DC operation: Integrated diode-resistor combination, coil rating 2.6W.
## **XTFC Manual Motor Controller**
## **XTFR Manual Motor Controller**
**==> picture [214 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
M M<br>3 ~ 3 ~<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-202**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **Accessories**
**1**
## _**Line Side Adapters**_
Line side adapters are required for use with XTPR MMPs only when used as Type E self-protected manual combination starters or as part of XTFC or XTFR Type F combination motor controllers. Not required for group installation.
||**Line-Side Adapters**2|**Catalog**|||**Catalog**|
|---|---|---|---|---|---|
||**For Use with…**|**Number**||**For Use with…**|**Number**|
|**XTPAXLSA**<br>~~(aie~~|Frame B XTPR to create a UL 508 Type E/F<br>manual combination starter|**XTPAXLSA**|**XTPAXLSAD**<br>ca|Frame D XTPR to create a UL 508<br>Type E/F manual combination starter|**XTPAXLSAD**4|
|**XTPAXIP2X**|Reduced size Frame D XTPR to create a UL 508<br>Type E/F manual combination starter (not to be|**XTPAXIP2X**||||
|a|used with 3-phase commoning links)|||~~ee~~|~~ee~~|
## _**Combination Connection Kits**_
Combination connection kits include the necessary components to field assemble a manual motor controller with an MMP (XTPR) and contactor (XTCE).
## **Non-Reversing Starters**
||||**Std.**||
|---|---|---|---|---|
||**For Use with …**|**Description/Composed of …**|**Pack**1|**Catalog Number**|
|**XTPAXTPCB**|XTPR…B + XTCE…B|Mechanical connection element for XTPR…B and contactor|1|**XTPAXTPCB**|
|||Main current wiring between XTPR…B and contactor in toolless plug connection|1||
|**XTPAXEMCB**<br>Cys|XTPR…B + XTCE…B|Cable guidance<br>Use as contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm2<br>external diameter or four cables up to 3.5 mm2external diameter<br>Mechanical connection element for XTPR…B and contactor<br>~~OO~~|1<br>1|**XTPAXEMCB**|
|||Main current wiring between XTPR…B and contactor screw in type connection|1||
|ar<br>)<br>||||||
||||||
|**XTPAXTPCC and**<br>**XTPAXTPCD**|XTPR…B + XTCE…C|DIN rail adapter plate|1|**XTPAXTPCC**|
||||||
||XTPR…D + XTCE…D|Main current wiring between XTPR and contactor|1|**XTPAXTPCD**|
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-203**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
## **Reversing Starters**
|**XTPCRB**<br>**XTPCRC**|**For Use with …**|**Description/Composed of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|
|---|---|---|
||XTPR…B + XTCE…B01_|Mechanical connection element for XTPR…B and contactor<br>1<br>**XTPAXTPCRB**<br>Reversing starter main current wiring in toolless plug connection<br>1<br>Control cables for electrical interlocking in toolless plug connection—<br>K1M: A1–K2M: 21, K1M: 21–K2M: A1, K1M: A2–K2M: A2<br>1<br>Cable guidance<br>1<br>Use as contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm2<br>external diameter or four cables up to 3.5 mm2external diameter.|
||XTPR…B + XTCE…C|DIN rail adapter plate<br>1<br>**XTPAXTPCRC**<br>Reversing starter main current wiring<br>1|
## **XTPAXEC_**
## **Electric Contact Module**
|**XTPCPB**<br>**XTPCRPB**<br>**XTPCPD**|**For Use with …**|**Description/Composed of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|
|---|---|---|
||XTPR…B + XTCE…C|Main current wiring between XTPR…B and contactor<br>5<br>**XTPAXECMC**<br>Use only in combination with busbar adapter|
||XTPR…D + XTCE…D|Main current wiring between XTPR…D and contactor<br>5<br>**XTPAXECMD**<br>Use only in combination with busbar adapter|
||**DIN Rail Adapter Plates**<br>**For Use with …**<br>**Description/Composed of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**||
||XTPAXTPCB<br>XTPAXTPCRB|45 mm wide adapter plate with one DIN rail<br>4<br>**XTPAXTPCPB**<br>Connection element for side-by-side positioning of further plates|
||XTPR…B + XTCE…C<br>XTPAXECMC|45 mm wide adapter plate with one DIN rail<br>4<br>**XTPAXTPCRPB**<br>Connection element for side-by-side positioning of further plates|
||XTPAXECMD<br>XTPR…D + XTCE…C<br>XTPR…D + XTCE…D|55 mm wide adapter plate with two DIN rails<br>4<br>**XTPAXTPCPD**<br>Connection cams for further plates<br>4<br>For use with reversing and star-delta starters|
||**Lateral Module**<br>**For Use with …**|**Description/Composed of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|
||—|Can be grouped on the DIN rail adapter<br>10<br>**XTPAXLM**<br>Expansion of the mounting width by 9 mm|
||**Connection Element**<br>**For Use with …**<br>**Description/Composed of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**||
||—<br>For connection of several DIN rail adapters<br>50<br>**XTPAXCNE**||
||**_Note_**<br>1Orders must be placed in multiples of package quantity listed.||
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-204**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Technical Data and Specifications**
**XTSC Non-Reversing Manual Motor Controllers (MMC)—Component Bill of Material Factory Assembled Manual Motor Protector + Contactor**
|**Assembled Manual**|**FLA Adjustment**<br>**Range/Overload**|**Component Catalog Numbers**<br>**Manual Motor**|**Combination**||**Manual Motor Protector**|
|---|---|---|---|---|---|
|**Motor Controller**1|**Release—Ir (Amps)**|**Protector**|**Connection Kit**|**Contactor**1|**Auxiliary Contact**|
|**XTSC Frame B MMP + Frame B Contactor**||||||
|**XTSCP16BB_**<br>**XTSCP25BB_**|0.1–0.16<br>0.16–0.25|XTPRP16BC1<br>XTPRP25BC1|XTPAXTPCB<br>XTPAXTPCB|XTCE007B10_<br>XTCE007B10_|XTPAXFA11<br>XTPAXFA11|
|**XTSCP40BB_**|0.25–0.4|XTPRP40BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTSCP63BB_**|0.4–0.63|XTPRP63BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTSC001BB_**|0.63–1|XTPR001BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTSC1P6BB_**<br>**XTSC2P5BB_**|1–1.6<br>1.6–2.5|XTPR1P6BC1<br>XTPR2P5BC1|XTPAXTPCB<br>XTPAXTPCB|XTCE007B10_<br>XTCE007B10_|XTPAXFA11<br>XTPAXFA11|
|**XTSC004BB_**|2.5–4|XTPR004BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTSC6P3BB_**|4–6.3|XTPR6P3BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTSC010BB_**|6.3–10|XTPR010BC1|XTPAXTPCB|XTCE009B10_|XTPAXFA11|
|**XTSC012BB_**|8–12|XTPR012BC1|XTPAXTPCB|XTCE012B10_|XTPAXFA11|
|**XTSC016BB_**|10–16|XTPR016BC1|XTPAXTPCB|XTCE015B10_|XTPAXFA11|
|**XTSC Frame B MMP + Frame C Contactor**<br>**XTSC020BC_**<br>16–20||XTPR020BC1|XTPAXTPCC|XTCE025C10_|XTPAXFA11|
|**XTSC025BC_**|20–25|XTPR025BC1|XTPAXTPCC|XTCE025C10_|XTPAXFA11|
|**XTSC032BC_**|25–32|XTPR032BC1|XTPAXTPCC|XTCE032C10_|XTPAXFA11|
|**XTSC Frame D MMP + Frame C Contactor**||||||
|**XTSC016DC_**|10–16|XTPR016DC1|2|XTCE018C10_|XTPAXFA1|
|**XTSC025DC_**|16–25|XTPR025DC1|2|XTCE025C10_|XTPAXFA11|
|**XTSC032DC_**<br>25–32<br>**XTSC Frame D MMP + Frame D Contactor**||XTPR032DC1|2|XTCE032C10_|XTPAXFA11|
|**XTSC040DD_**|32–40|XTPR040DC1|XTPAXTPCD3|XTCE040D00_|XTPAXFA11|
|**XTSC050DD_**|40–50|XTPR050DC1|XTPAXTPCD3|XTCE050D00_|XTPAXFA11|
|**XTSC058DD_**|50–58|XTPR058DC1|XTPAXTPCD3|XTCE065D00_|XTPAXFA11|
|**XTSC063DD_**|55–65|XTPR063DC1|XTPAXTPCD3|XTCE065D00_|XTPAXFA11|
## _**Notes**_
> 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
- 2 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
- 3 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-205**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTSR Reversing Manual Motor Controllers (MMC)—Component Bill of Material**
**Factory Assembled Manual Motor Protector + Contactor**
|**Assembled Manual**|**FLA Adjustment**<br>**Range/Overload**|**Component Catalog Numbers**<br>**Manual Motor**|**Combination**||**Manual Motor Protector**|
|---|---|---|---|---|---|
|**Motor Controller**1<br>**Release—Ir (Amps)**<br>**XTSR Frame B MMP + Frame B Contactor**||**Protector**|**Connection Kit**|**Contactor**1|**Auxiliary Contact**|
|**XTSRP16BB_**|0.1–0.16|XTPRP16BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSRP25BB_**|0.16–0.25|XTPRP25BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSRP40BB_**|0.25–0.4|XTPRP40BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSRP63BB_**|0.4–0.63|XTPRP63BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSR001BB_**|0.63–1|XTPR001BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSR1P6BB_**<br>**XTSR2P5BB_**|1–1.6<br>1.6–2.5|XTPR1P6BC1<br>XTPR2P5BC1|XTPAXTPCRB<br>XTPAXTPCRB|(2) XTCE007B01_<br>(2) XTCE007B01_|XTPAXFA11<br>XTPAXFA11|
|**XTSR004BB_**|2.5–4|XTPR004BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSR6P3BB_**|4–6.3|XTPR6P3BC1|XTPAXTPCRB|(2) XTCE007B01_|XTPAXFA11|
|**XTSR010BB_**|6.3–10|XTPR010BC1|XTPAXTPCRB|(2) XTCE009B01_|XTPAXFA11|
|**XTSR012BB_**<br>8–12<br>**XTSR Frame B MMP + Frame C Contactor**||XTPR012BC1|XTPAXTPCRB|(2) XTCE012B01_|XTPAXFA11|
|**XTSR016BC_**|10–16|XTPR016BC1|XTPAXTPCRC|(2) XTCE018C01|XTPAXFA11|
|**XTSR020BC_**|16–20|XTPR020BC1|XTPAXTPCRC|(2) XTCE025C01_|XTPAXFA11|
|**XTSR025BC_**|20–25|XTPR025BC1|XTPAXTPCRC|(2) XTCE025C01_|XTPAXFA11|
|**XTSR032BC_**|25–32|XTPR032BC1|XTPAXTPCRC|(2) XTCE032C01_|XTPAXFA11|
|**XTSR Frame D MMP + Frame C Contactor**||||||
|**XTSR016DC_**<br>**XTSR025DC_**|10–16<br>16–25|XTPR016DC1<br>XTPR025DC1|2<br>2|(2) XTCE018C01<br>(2) XTCE025C01_|XTPAXFA11<br>XTPAXFA11|
|**XTSR032DC_**|25–32|XTPR032DC1|2|(2) XTCE032C01_|XTPAXFA11|
|**XTSR Frame D MMP + Frame D Contactor**||||||
|**XTSR040DD_**|32–40|XTPR040DC1|3|(2) XTCE040D00_|XTPAXFA11|
|**XTSR050DD_**|40–50|XTPR050DC1|3|(2) XTCE050D00_|XTPAXFA11|
|**XTSR058DD_**|50–58|XTPR058DC1|3|(2) XTCE065D00_|XTPAXFA11|
|**XTSR063DD_**|55–65|XTPR063DC1|3|(2) XTCE065D00_|XTPAXFA11|
## _**Notes**_
> 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
> 2 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
> 3 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-206**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTFC Non-Reversing Combination Motor Controllers—Component Bill of Material**
**Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter**
|**Assembled**<br>**Combination**|**FLA Adjustment Range/**<br>**Overload Release—Ir**|**Component Catalog Numbers**<br>**Line Side**<br>**Manual Motor**|**Component Catalog Numbers**<br>**Line Side**<br>**Manual Motor**|**Combination**||**Manual Motor Protector**|
|---|---|---|---|---|---|---|
|**Motor Controller**1<br>**(Amps)**<br>**XTFC Frame B MMP + Frame B Contactor**||**Adapter**|**Protector**|**Connection Kit**|**Contactor**1|**Auxiliary Contact**|
|**XTFCP16BB_**2|0.1–0.16|XTPAXLSA|XTPRP16BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFCP25BB_**2|0.16–0.25|XTPAXLSA|XTPRP25BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFCP40BB_**2|0.25–0.4|XTPAXLSA|XTPRP40BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFCP63BB_**2|0.4–0.63|XTPAXLSA|XTPRP63BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFC001BB_**2|0.63–1|XTPAXLS|XTPR001BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFC1P6BB_**2<br>**XTFC2P5BB_**2|1–1.6<br>1.6–2.5|XTPAXLSA<br>XTPAXLSA|XTPR1P6BC1<br>XTPR2P5BC1|XTPAXTPCB<br>XTPAXTPCB|XTCE007B10_<br>XTCE007B10_|XTPAXFA11<br>XTPAXFA11|
|**XTFC004BB_**2|2.5–4|XTPAXLSA|XTPR004BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFC6P3BB_**|4–6.3|XTPAXLSA|XTPR6P3BC1|XTPAXTPCB|XTCE007B10_|XTPAXFA11|
|**XTFC010BB_**|6.3–10|XTPAXLSA|XTPR010BC1|XTPAXTPCB|XTCE009B10_|XTPAXFA11|
|**XTFC012BB_**<br>**XTFC016BB_**|8–12<br>10–16|XTPAXLSA<br>XTPAXLSA|XTPR012BC1<br>XTPR016BC1|XTPAXTPCB<br>XTPAXTPCB|XTCE012B10_<br>XTCE015B10_|XTPAXFA11<br>XTPAXFA11|
|**XTFC Frame B MMP + Frame C Contactor**|||||||
|**XTFC6P3BC_**2|4–6.3|XTPAXLSA|XTPR6P3BC1|XTPAXTPCC|XTCE018C10_|XTPAXFA11|
|**XTFC010BC_**2|6.3–10|XTPAXLSA|XTPR010BC1|XTPAXTPCC|XTCE018C10_|XTPAXFA11|
|**XTFC012BC_**2|8–12|XTPAXLSA|XTPR012BC1|XTPAXTPCC|XTCE018C10_|XTPAXFA11|
|**XTFC016BC_**2|10–16|XTPAXLSA|XTPR016BC1|XTPAXTPCC|XTCE018C10_|XTPAXFA11|
|**XTFC020BC_**<br>**XTFC025BC_**|16–20<br>20–25|XTPAXLSA<br>XTPAXLSA|XTPR020BC1<br>XTPR025BC1|XTPAXTPCC<br>XTPAXTPCC|XTCE025C10_<br>XTCE025C10_|XTPAXFA11<br>XTPAXFA11|
|**XTFC032BC_**|25–32|XTPAXLSA|XTPR032BC1|XTPAXTPCC|XTCE032C10_|XTPAXFA11|
|**XTFC Frame D MMP + Frame C Contactor**|||||||
|**XTFC016DC_**|10–16|XTPAXLSAD|XTPR016DC1|3|XTCE018C10_|XTPAXFA11|
|**XTFC025DC_**|16–25|XTPAXLSAD|XTPR025DC1|3|XTCE025C10_|XTPAXFA11|
|**XTFC032DC_**|25–32|XTPAXLSAD|XTPR032DC1|3|XTCE032C10_|XTPAXFA11|
|**XTFC Frame D MMP + Frame D Contactor**<br>**XTFC016DD_**2<br>10–16||XTPAXLSAD|XTPR016DC1|XTPAXTPCD|XTCE040D00_|XTPAXFA11|
|**XTFC025DD_**2|16–20|XTPAXLSAD|XTPR025DC1|XTPAXTPCD|XTCE040D00_|XTPAXFA11|
|**XTFC032DD_**2|20–25|XTPAXLSAD|XTPR032DC1|XTPAXTPCD|XTCE040D00_|XTPAXFA11|
|**XTFC040DD_**2|32–40|XTPAXLSAD|XTPR040DC1|XTPAXTPCD4|XTCE040D00_|XTPAXFA11|
|**XTFC050DD_**2<br>**XTFC058DD_**2|40–50<br>50–58|XTPAXLSAD<br>XTPAXLSAD|XTPR050DC1<br>XTPR058DC1|XTPAXTPCD4<br>XTPAXTPCD4|XTCE050D00_<br>XTCE065D00_|XTPAXFA11<br>XTPAXFA11|
|**XTFC063DD_**|55–65|XTPAXLSAD|XTPR063DC1|XTPAXTPCD4|XTCE065D00_|XTPAXFA11|
## _**Notes**_
- 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
- 2 Indicates Type E with contactor UL 508 combination. Not all XTFC part numbers feature UL 508 Type E with contactor combinations.
- 3 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
- 4 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).
**Note:** Type E UL 508 combinations can be assembled in the field and DO NOT require the manual motor protector auxiliary contact XTPAXFA11. The connection can also be wired and does not require use of the XT connector.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-207**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTFR Reversing Combination Motor Controllers—Component Bill of Material**
**Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter**
|**Assembled Combination**<br>**FLA Adjustment Range/**<br>**Overload Release—Ir**|**Assembled Combination**<br>**FLA Adjustment Range/**<br>**Overload Release—Ir**|**Component Catalog Numbers**<br>**Line Side**<br>**Manual Motor**|**Component Catalog Numbers**<br>**Line Side**<br>**Manual Motor**|**Combination**||**Manual Motor Protector**|
|---|---|---|---|---|---|---|
|**Motor Controller**1<br>**XTFR Frame B MMP**|**(Amps)**<br>**+ Frame B Contactor**|**Adapter**|**Protector**|**Connection Kit**|**Contactor**1|**Auxiliary Contact**|
|**XTFRP16BB_**2|0.1–0.16|XTPAXLSA|XTPRP16BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFRP25BB_**2|0.16–0.25|XTPAXLSA|XTPRP25BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFRP40BB_**2|0.25–0.4|XTPAXLSA|XTPRP40BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFRP63BB_**2|0.4–0.63|XTPAXLSA|XTPRP63BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFR001BB_**2|0.63–1|XTPAXLSA|XTPR001BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFR1P6BB_**2<br>**XTFR2P5BB_**2|1–1.6<br>1.6–2.5|XTPAXLSA<br>XTPAXLSA|XTPR1P6BC1<br>XTPR2P5BC1|XTPAXTPCRB<br>XTPAXTPCRB|XTCE007B01_3<br>XTCE007B01_3|XTPAXFA11<br>XTPAXFA11|
|**XTFR004BB_**2|2.5–4|XTPAXLSA|XTPR004BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFR6P3BB_**|4–6.3|XTPAXLSA|XTPR6P3BC1|XTPAXTPCRB|XTCE007B01_3|XTPAXFA11|
|**XTFR010BB_**|6.3–10|XTPAXLSA|XTPR010BC|XTPAXTPCRB|XTCE009B01_3|XTPAXFA11|
|**XTFR012BB_**<br>**XTFR Frame B MMP**|8–12<br>**+ Frame C Contactor**|XTPAXLSA|XTPR012BC1|XTPAXTPCRB|XTCE012B01_3|XTPAXFA11|
|**XTFR6P3BC_**2|4–6.3|XTPAXLSA|XTPR6P3BC1|XTPAXTPCRC|XTCE018C10_3|XTPAXFA11|
|**XTFR010BC_**2|6.3–10|XTPAXLSA|XTPR103BC1|XTPAXTPCRC|XTCE018C10_3|XTPAXFA11|
|**XTFR012BC_**2|8–12|XTPAXLSA|XTPR123BC1|XTPAXTPCRC|XTCE018C10_3|XTPAXFA11|
|**XTFR016BC_**2|10–16|XTPAXLSA|XTPR016BC1|XTPAXTPCRC|XTCE018C01_3|XTPAXFA11|
|**XTFR020BC_**|16–20|XTPAXLSA|XTPR020BC1|XTPAXTPCRC|XTCE025C01_3|XTPAXFA11|
|**XTFR025BC_**<br>**XTFR032BC_**|20–25<br>25–32|XTPAXLSA<br>XTPAXLSA|XTPR025BC1<br>XTPR032BC1|XTPAXTPCRC<br>XTPAXTPCRC|XTCE025C01_3<br>XTCE032C01_3|XTPAXFA11<br>XTPAXFA11|
|**XTFR Frame D MMP**|**+ Frame C Contactor**||||||
|**XTFR016DC_**|10–16|XTPAXLSAD|XTPR016DC1|3|XTCE018C01_3|XTPAXFA11|
|**XTFR025DC_**|16–25|XTPAXLSAD|XTPR025DC1|3|XTCE025C01_3|XTPAXFA11|
|**XTFR032DC_**|25–32|XTPAXLSAD|XTPR032DC1|3|XTCE032C01_3|XTPAXFA11|
|**XTFR Frame D MMP**|**+ Frame D Contactor**||||||
|**XTFR016DD_**2<br>**XTFR025DD_**2|10–16<br>16–25|XTPAXLSAD<br>XTPAXLSAD|XTPR016DC1<br>XTPR025DC1|3<br>3|XTCE040D00_3<br>XTCE040D00_3|XTPAXFA11<br>XTPAXFA11|
|**XTFR026DD_**2|25–32|XTPAXLSAD|XTPR032DC1|3|XTCE040D00_3|XTPAXFA11|
|**XTFR040DD_**2|32–40|XTPAXLSAD|XTPR040DC1|4|XTCE040D00_3|XTPAXFA11|
|**XTFR050DD_**2|40–50|XTPAXLSAD|XTPR050DC1|4|XTCE050D00_3|XTPAXFA11|
|**XTFR058DD_**2<br>**XTFR063DD_**|50–58<br>55–65|XTPAXLSAD<br>XTPAXLSAD|XTPR058DC1<br>XTPR063DC1|4<br>4|XTCE065D00_3<br>XTCE065D00_3|XTPAXFA11<br>XTPAXFA11|
## _**Notes**_
> 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
- 2 Indicates Type E with contactor UL 508 combination. Not all XTFR part numbers feature UL 508 Type E with contactor combinations.
- 3 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
- 4 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).
**Note:** Type E UL 508 combinations can be assembled in the field and DO NOT require the manual motor protector auxiliary contact XTPAXFA11. The connection can also be wired and does not require use of the XT connector.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-208**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Manual Motor Controllers Short-Circuit Ratings for UL/CSA Group Installations**
**XTSC and XTSR Manual Motor Controllers (MMC)**
|**Assembled Controller**1|**Assembled Controller**1|**FLA Adjustment**<br>**Range/Overload**<br>**Release—**|**Short-Circuit**<br>**Release—**|**Group Installation, UL/CSA**<br>**Max. rms Symmetrical Short-Circuit**<br>**Ratings (kA/kA with Current Limiter)**|**Group Installation, UL/CSA**<br>**Max. rms Symmetrical Short-Circuit**<br>**Ratings (kA/kA with Current Limiter)**|**Group Installation, UL/CSA**<br>**Max. rms Symmetrical Short-Circuit**<br>**Ratings (kA/kA with Current Limiter)**|**Maximum Upstream Protective Device**<br>**(A/A with Current Limiter)**<br>**Maximum Fuse**<br>**Maximum Circuit**|**Maximum Upstream Protective Device**<br>**(A/A with Current Limiter)**<br>**Maximum Fuse**<br>**Maximum Circuit**|
|---|---|---|---|---|---|---|---|---|
|**Non-Reversing**|**Reversing**|**Ir (Amps)**|**Irm (Amps)**|**240V**|**480V**|**600V**|**600V**|**Breaker 600V**|
|**XTSC and XTSR Frame B MMP + Frame B Contactor**|||||||||
|**XTSCP16BB_**<br>**XTSCP25BB_**|**XTSRP16BB_**<br>**XTSRP25BB_**|0.1–0.16<br>0.16–0.25|2.2<br>3.5|65<br>65|65<br>65|50<br>50|600<br>600|600<br>600|
|**XTSCP40BB_**|**XTSRP40BB_**|0.25–0.4|5.6|65|65|50|600|600|
|**XTSCP63BB_**|**XTSRP63BB_**|0.4–0.36|8.82|65|65|50|600|600|
|**XTSC001BB_**|**XTSR001BB_**|0.36–1|14.0|65|65|50|600|600|
|**XTSC1P6BB_**|**XTSR1P6BB_**|1–1.6|22.4|65|65|50|600|600|
|**XTSC2P5BB_**|**XTSR2P5BB_**|1.6–2.|5|35|65|65|50|600|
|**XTSC004BB_**<br>**XTSC6P3BB_**|**XTSR004BB_**<br>**XTSR6P3BB_**|2.5–4<br>4–6.3|56<br>88.2|65<br>65|65<br>65|50<br>50|600<br>600|600<br>600|
|**XTSC010BB_**|**XTSR010BB_**|6.3–10|140|65|65|22|10/600|15/600|
|**XTSC012BB_**|**XTSR012BB_**|8–12|168|65|65|22|10/600|15/600|
|**XTSC and XTSR Frame B MMP + Frame C Contactor**|||||||||
|**XTSC016BC_**<br>**XTSC020BC_**|**XTSR016BC_**<br>**XTSR020BC_**|10–16<br>16–20|224<br>280|42<br>18|42<br>18|50<br>18|10/600<br>10/600|15/600<br>15/600|
|**XTSC025BC_**|**XTSR025BC_**|20–25|350|18|18|18|10/600|15/600|
|**XTSC032BC_**|**XTSR032BC_**|25–32|448|18|18|18|10/600|15/600|
|**XTSC and XTSR Frame D MMP + Frame C Contactor**|||||||||
|**XTSC016DC_**|**XTSR016DC_**|10–16|224|65|65|22|600|600|
|**XTSC025DC_**|**XTSR025DC_**|16–25|350|65|65|22|600|600|
|**XTSC032DC_**<br>**XTSR032DC_**<br>25–32<br>**XTSC and XTSR Frame D MMP + Frame D Contactor**|||448|65|65|22|600|600|
|**XTSC040DD_**|**XTSR040DD_**|32–40|560|65|65|22|600|600|
|**XTSC050DD_**|**XTSR050DD_**|40–50|700|65|65|22|600|600|
|**XTSC058DD_**|**XTSR058DD_**|50–58|812|65|65|22|—|—|
|**XTSC063DD_**|**XTSR063DD_**|58–63|882|65|65|—|—|—|
## _**Note**_
> 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-209**
1.1
_**XT**_ IEC Power Control
## IEC Contactors and Starters
**Combination Motor Controllers (Line Side Adapter + Manual Motor Protector + Contactor) 1 UL 508 Type F Self-Protected**
## **XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F**
|**Assembled Controller**1|**Assembled Controller**1|||**UL 508 Type F Application**2|**UL 508 Type F Application**2||||
|---|---|---|---|---|---|---|---|---|
|||**FLA Adjustment**<br>**Range/Overload**|**Short-Circuit**|**Max. rms**|**Symmetrical Short-Circuit**|**Ratings (kA)**|**Maximum Upstream**<br>**Protective Device (A)**2||
|**Non-Reversing**|**Reversing**|**Release—**<br>**Ir (Amps)**|**Release—**<br>**Irm (Amps)**|**240V**|**480V**|**600V**|**Maximum Fuse**<br>**600V**|**Maximum Circuit**<br>**Breaker 600V**|
|**XTFC and XTFR Frame B MMP +**<br>**XTFCP16BB_**<br>**XTFRP16BB_**||**Frame B Contactor**<br>0.1–0.16|2.2|65|65|18|Not required|Not required|
|**XTFCP25BB_**|**XTFRP25BB_**|0.16–0.25|3.5|65|65|18|Not required|Not required|
|**XTFCP40BB_**|**XTFRP40BB_**|0.25–0.4|5.6|65|65|18|Not required|Not required|
|**XTFCP63BB_**|**XTFRP40BB_**|0.4–0.63|8.82|65|65|18|Not required|Not required|
|**XTFC001BB_**<br>**XTFC1P6BB_**|**XTFRP63BB_**<br>**XTFR1P6BB_**|0.63–1<br>1–1.6|14<br>22.4|65<br>65|65<br>65|18<br>18|Not required<br>Not required|Not required<br>Not required|
|**XTFC2P5BB_**|**XTFR2P5BB_**|1.6–2.5|35|65|65|18|Not required|Not required|
|**XTFC001BB_**|**XTFR004BB_**|2.5–4.0|56|65|65|18|Not required|Not required|
|**XTFC6P3BB_**|**XTFR6P3BB_**|4.0–6.3|88.2|65|65|18|Not required|Not required|
|**XTFC010BB_**|**XTFR010BB_**|6.3–10|140|65|65|18|Not required|Not required|
|**XTFC012BB_**|**XTFR012BB_**|8–12|168|65|65|18|Not required|Not required|
|**XTFC016BB_**<br>**—**<br>**XTFC and XTFR Frame B MMP +**||10–16<br>**Frame C Contactor**|224|18|18|—|Not required|Not required|
|**XTFC016BC_**3|**XTFR016BC_**3|10–16|224|18|18|—|Not required|Not required|
|**XTFC020BC_**|**XTFR020BC_**|16–20|280|18|18|—|Not required|Not required|
|**XTFC025BC_**|**XTFR025BC_**|20–25|350|18|18|—|Not required|Not required|
|**XTFC032BC_**|**XTFR032BC_**|25–32|448|18|18|—|Not required|Not required|
|**XTFC and XTFR Frame D MMP +**||**Frame C Contactor**|||||||
|**XTFC016DC_**<br>**XTFC025DC_**|**XTFR016DC_**<br>**XTFR025DC_**|10–16<br>16–25|224<br>350|65<br>65|65<br>65|30<br>30|Not required<br>Not required|Not required<br>Not required|
|**XTFC032DC_**|**XTFR032DC_**|25–32|448|65|65|50|Not required|Not required|
|**XTFC and XTFR Frame D MMP +**||**Frame D Contactor**|||||||
|**XTFC040DD_**|**XTFR040DD_**|32–40|560|65|65|50|Not required|Not required|
|**XTFC050DD_**<br>**XTFC058DD_**|**XTFR050DD_**<br>**XTFR058DD_**|40–50<br>50–58|700<br>812|65<br>65|65<br>65|—<br>—|Not required<br>Not required|Not required<br>Not required|
|**XTFC063DD_**|**XTFR063DD_**|55–65|882|65|65|—|Not required|Not required|
## _**Notes**_
> 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
- 2 For UL 508 Type F applications, the combination motor controller assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required.
- 3 For 65 kA UL rating, use Type E rating with contactor.
**Note:** A **Type F** combination motor controller consists of a Type E manual self-protected motor controller and a magnetic motor controller.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-210**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Combination Motor Controllers Short-Circuit Ratings for UL 508 Type E Application**
**XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F/Type E**
|**Assembled Controller**1|**Assembled Controller**1|**FLA Adjustment**<br>**Range/Overload**<br>**Release—**|**Short-Circuit**<br>**Release—**|**UL 508 Type F Application**<br>**Max. rms Symmetrical Short-Circuit**<br>**Ratings (kA)**|**UL 508 Type F Application**<br>**Max. rms Symmetrical Short-Circuit**<br>**Ratings (kA)**|**UL 508 Type F Application**<br>**Max. rms Symmetrical Short-Circuit**<br>**Ratings (kA)**|**Maximum Upstream**<br>**Protective Device (A)**<br>**Maximum Fuse**|2<br>**Maximum Circuit**|
|---|---|---|---|---|---|---|---|---|
|**Non-Reversing**|**Reversing**|**Ir (Amps)**|**Irm (Amps)**|**240V**|**480/277V**|**600/347V**|**600V**|**Breaker 600V**|
|**XTFC and XTFR Frame B MMP + Frame B Contactor**|||||||||
|**XTFCP16BB_**<br>**XTFCP25BB_**|**XTFRP16BB_**<br>**XTFRP25BB_**|0.1–0.16<br>0.16–0.25|2.2<br>3.5|65<br>65|65<br>65|—<br>—|Not required<br>Not required|Not required<br>Not required|
|**XTFCP40BB_**|**XTFRP40BB_**|0.25–0.4|5.6|65|65|—|Not required|Not required|
|**XTFCP63BB_**|**XTFRP63BB_**|0.4–0.63|8.82|65|65|—|Not required|Not required|
|**XTFC001BB_**|**XTFR001BB_**|0.63–1|14|65|65|—|Not required|Not required|
|**XTFC1P6BB_**<br>**XTFC2P5BB_**|**XTFR1P6BB_**<br>**XTFR2P5BB_**|1–1.6<br>1.6–2.5|22.4<br>35|65<br>65|65<br>65|—<br>—|Not required<br>Not required|Not required<br>Not required|
|**XTFC004BB_**<br>**XTFR004BB_**<br>2.5–4<br>**XTFC and XTFR Frame B MMP + Frame C Contactor**|||56|65|65|—|Not required|Not required|
|**XTFC6P3BC_**|**XTFR6P3BC_**|4–6.3|88.2|65|65|—|Not required|Not required|
|**XTFC010BC_**|**XTFR010BC_**|6.3–10|140|65|65|—|Not required|Not required|
|**XTFC012BC_**|**XTFR012BC_**|8–12|168|65|65|—|Not required|Not required|
|**XTFC016BC_**<br>**XTFR016BC_**<br>10–16<br>**XTFC and XTFR Frame D MMP + Frame D Contactor**|||224|65|65|—|Not required|Not required|
|**XTFC016DD_**|**XTFR016DD_**|10–16|224|65|65|—|Not required|Not required|
|**XTFC025DD_**|**XTFR025DD_**|16–25|350|65|65|—|Not required|Not required|
|**XTFC032DD_**|**XTFR032DD_**|25–32|448|65|65|—|Not required|Not required|
|**XTFC040DD_**|**XTFR040DD_**|32–40|560|65|65|—|Not required|Not required|
|**XTFC050DD_**|**XTFR050DD_**|40–50|700|65|65|—|Not required|Not required|
|**XTFC058DD_**<br>**XTFC063DD_**|**XTFR058DD_**<br>**XTFR063DD_**|50–58<br>55–65|812<br>882|65<br>65|65<br>65|—<br>—|Not required<br>Not required|Not required<br>Not required|
## _**Notes**_
> 1 Underscore (_) indicates magnetic coil suffix required. See **Page V5-T1-196** .
> 2 For UL 508 Type E applications, the assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-211**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Dimensions**
Approximate Dimensions in mm [in]
## **XTSC…BB_**
**==> picture [228 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
32.5 [1.28]<br>To Terminals<br>178.5<br>[7.03]<br>49.7 [1.96]<br>To Terminals<br>95.7 45<br>[3.77] [1.77]<br>**----- End of picture text -----**<br>
## **XTSR…BB_**
**==> picture [270 x 221] intentionally omitted <==**
**----- Start of picture text -----**<br>
32.5 [1.28]<br>To Terminals<br>183.4<br>[7.22]<br>49.7 [1.96]<br>To Terminals<br>95.3 90.3<br>[3.75] [3.55]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-212**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **XTSC…BC_**
**==> picture [428 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Holes 57.5 [2.26]<br>for M4 Screws To Terminals<br>or #8 Screws<br>(4 Places)<br>210.8 [8.30] 228.8 235.7<br>[9.28]<br>Mounting [9.01]<br>86.8<br>[3.42]<br>To Terminals<br>9 [.35]<br>34 124.3 45.2<br>[1.34] [4.89] [1.78]<br>**----- End of picture text -----**<br>
## **XTSR…BC_**
**==> picture [474 x 300] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Holes for<br>M4 Screws or #8 Screws 57.5 [2.26]<br>(4 Places) To Terminals<br>210.8 [8.30] 228.8 235.4<br>Mounting [9.01] [9.27]<br>86.8 [3.42]<br>To<br>Terminals<br>9 [.35]<br>34 124.3 89.6<br>[1.34] [4.89] [3.53]<br>45<br>[1.77]<br>79 5.3<br>[3.11] [.21]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-213**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **XTSC…DD_**
**==> picture [466 x 603] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Holes for 196 [7.72]<br>M5 Screws or #10 Screws 83.4 [3.28]<br>(4 Places) To Terminals<br>266 [10.47] 284<br>Mounting [11.18]<br>142.8<br>[5.62]<br>To Coil<br>Terminals<br>9 [.35]<br>158.5<br>55 [2.17]<br>[6.24]<br>43.4 [1.71] 172.1 [6.78]<br>Mounting To Optional Aux. Contacts<br>XTFC…BB_<br>36.3 [1.43]<br>To Terminals<br>209.2<br>[8.24]<br>49.7 [1.96]<br>To Terminals<br>95.7 [3.77] 45 [1.77]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-214**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **XTFR…BB_**
**==> picture [272 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
36.3 [1.43]<br>To Terminals<br>214.2<br>[8.43]<br>49.7 [1.96]<br>To Terminals<br>95.3 90.3<br>[3.75] [3.55]<br>**----- End of picture text -----**<br>
**==> picture [46 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTFC…BC_<br>**----- End of picture text -----**<br>
**==> picture [448 x 299] intentionally omitted <==**
**----- Start of picture text -----**<br>
34 [1.34]<br>Mounting 61.3 [2.41]<br>To Terminals<br>Mounting Holes<br>for M4 Screws<br>or #8 Screws<br>(4 Places)<br>266.7<br>[10.50]<br>210.8 [8.30] 228.8 235.7<br>Mounting [9.01] [9.28]<br>86.8 [3.42]<br>To Terminals<br>9 [.35]<br>124.3 45.2<br>[4.89] [1.78]<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-215**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
Approximate Dimensions in mm [in]
## **XTFR…BC_**
**==> picture [457 x 279] intentionally omitted <==**
**----- Start of picture text -----**<br>
61.3 [2.41]<br>To Terminals<br>Mounting Holes for<br>M4 Screws or #8 Screws<br>(8 Places)<br>266.4<br>[10.49]<br>235.4<br>210.8 [9.27]<br>[8.30]<br>228.8<br>[9.01]<br>86.8 [3.42]<br>To Terminals<br>9 [.35]<br>34 [1.34] 124.3 [4.89] 89.6 [3.53]<br>45 [1.77]<br>79 [3.11] 5.3 [.21]<br>**----- End of picture text -----**<br>
## **XTFC…DD_**
**==> picture [458 x 297] intentionally omitted <==**
**----- Start of picture text -----**<br>
86 [3.39]<br>Mounting Holes for To Line Side<br>M5 Screws or #10 Screws Connector<br>(4 Places)<br>297<br>[11.69]<br>266 [10.47]<br>Mounting 284<br>[11.18]<br>142.8<br>[5.62]<br>To Coil<br>Terminals<br>9 [.35]<br>43.4 [1.71] 158.5 [6.24] 55 [2.17]<br>Mounting 172.1 [6.78] To Optional Aux. Contacts<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-216**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**==> picture [110 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT Electronic Manual Motor Protector<br>**----- End of picture text -----**<br>
## **Contents**
**1**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-218**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-219**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-221**|
|Technical Data and Specifications . . . . . . . . . .|**V5-T1-227**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>EMS—Electronic Motor Starter . . . . . . . . . . . . . . .|**V5-T1-229**<br>**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## _**XT**_ **Electronic Manual Motor Protector**
## **Product Description**
The _**XT**_ Electronic Manual Motor Protector provides the same functionality as the _**XT**_ thermal manual motor protector, but with an added level of flexibility and selectability. The XTPE incorporates electronic control technology to enable more options and larger dial setting ranges. The trip units are interchangeable, allowing users to exchange as needed using the same base. The reduced number of part numbers decreases bill of material complexity while reducing inventory demands. The XTPE electronic manual motor protector includes the following features:
- 4:1 max to min overcurrent dial setting range
- Selectable trip class (5, 10, 15, 20)
- Interchangeable trip units
- Three base units (12, 32 and 65A)
- Common accessories with the XTPR
## **Features and Benefits**
## **Advanced Trip Unit**
In addition to the selectability, the XTPE is also available with an advanced trip unit that can communicate system data and protector data thru SmartWire-DT. SmartWire-DT is an innovative cost effective connection technology that enables quick installation of control wiring to the starter through a single green cable. When on SmartWire-DT, the XTPE can communicate the following:
- Current Values
- Maximum phase current
- Overload warning
- Diagnostics Data
- Overload fault
- Cause of trip (overcurrent or short circuit)
- Phase loss
- Trip via TEST
- Status Messages
- Control unit type
- Overload setting
- Time-lag
- Switching status
## **XTPE Electronic MMP**
The XTPE Electronic MMP provides the selectability, control, and insight options that give panel builders and OEMs the solutions necessary to enhance motor control designs while reducing total costs.
## **Standards and Certifications**
- CE approved
- UL Listed File No. E36332
- UL 508 group motor and Type E
- IEC/EN 60947
- CSA File 012528, Class 3211-05
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-217**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **—Manual Motor Protector**
**==> picture [431 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT PE 004 B CS<br>Designation Trip Type<br>XT = XT line of IEC control Type CS = Standard<br>PE = Electronic MMP Overload Release MMP Frame CA = Advanced (SmartWire-DT)<br>1P2 = 0.3–1.2A B = 45 mm<br>004 = 1–4A D = 55 mm<br>012 = 3–12A<br>032 = 8–32A<br>065 = 16–65A<br>**----- End of picture text -----**<br>
**==> picture [502 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
XT —Combinations<br>XT FCE 004 B C CS A<br>Designation Coil Voltage<br>XT = XT line of IEC control Type A = 110V 50 Hz, 120V 60 Hz<br>FCE = Electronic B = 220V 50 Hz, 240V 60 Hz<br>combination motor F = 230V 50 Hz<br>controller T = 24V 50/60 Hz<br>TD = 24 Vdc<br>Overload Release MMP Frame Contactor Frame Trip Type<br>1P2 = 0.3–1.2A B = 45 mm C = 45 mm CS = Selectable class 5, 10, 15, 20<br>004 = 1–4A CA = Selectable, advanced<br>012 = 3–12A<br>032 = 8–32A<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-218**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Product Selection**
## _**XT Electronic Manual Motor Protector**_
## **B Frame**
## **MMP Base**
||||||**IEC**|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|**Maximum**<br>**Amperage**|**UL/CSA**<br>**Maximum Three-Phase hp Ratings**<br>**200V**|**Maximum Three-Phase hp Ratings**<br>**240V**<br>**480V**||**Maximum Three-Phase hp Ratings**<br>**600V**|**Maximum Motor kW Ratings**<br>**220V**<br>**230V**<br>**240V**|**Maximum Motor kW Ratings**<br>**380V**<br>**400V**<br>**415V**<br>**440V**||**500V**|**600V**<br>**690V**|**Base Unit**<br>**Type Number**|**Catalog Number**|
|12|3|3|7.5|10|3|5.5|5.5|5.5|7.5|PKE12|**XTPE012B**|
|32|5|7.5|15|20|7.5|15|15|18.5|30|PKE32|**XTPE032B**|
|65|15|15|40|40|18.5|30|37|45|55|PKE65|**XTPE065D**|
## **B Frame**
## **MMP Trip Units**
|||||||**IEC**|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Overload**|**For Use with**|**UL/CSA**<br>**Maximum Three-Phase hp Ratings**||||**Maximum Motor kW Ratings**<br>**220V**<br>**380V**||**Maximum Motor kW Ratings**|||**Trip Unit**||
|**Release Setting**<br>**Amp Range**|**Base Catalog**<br>**Number**|**200V**|**240V**|**480V**|**600V**|**230V**<br>**240V**|**400V**<br>**415V**|**440V**|**500V**|**600V**<br>**690V**|**Type Number**|**Catalog Number**|
|0.3–1.2<br>1–4|XTPE012B<br>XTPE012B|1<br>0.75|1<br>0.75|0.5<br>2|0.5<br>3|0.18<br>0.75|0.37<br>1.5|0.37<br>1.5|0.37<br>2.2|0.75<br>3|PKE-XTU-1,2<br>PKE-XTU-4|**XTPEXT1P2B**<br>**XTPEXT004B**|
|3–12|XTPE012B|3|3|7.5|10|3|5.5|5.5|5.5|7.5|PKE-XTU-12|**XTPEXT012B**|
||XTPE032B||||||||||||
|8–32|XTPE032B|5|7.5|15|20|7.5|15|15|18.5|30|PKE-XTU-32|**XTPEXT032B**|
|8–32|XTPE065D|7.5|7.5|20|25|7.5|15|15|18.5|30|PKE-XTUW-32|**XTPEXT032D**|
|16–65|XTPE065D|15|15|40|40|18.5|30|37|45|55|PKE-XTU-65|**XTPEXT065D**|
## **B Frame**
## **MMP Advanced Trip Units Used with SmartWire-DT**
|||||||**IEC**|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||**UL/CSA**||||**Maximum Motor kW Ratings**||**Maximum Motor kW Ratings**|||||
|**Overload**<br>**Release Setting**|**For Use with**<br>**Base Catalog**|**Maximum Three-Phase hp Ratings**||||**220V**<br>**230V**|**380V**<br>**400V**|||**600V**|**Trip Unit**||
|**Amp Range**<br>0.3–1.2|**Number**<br>XTPE012B|**200V**<br>1|**240V**<br>1|**480V**<br>0.5|**600V**<br>0.5|**240V**<br>0.18|**415V**<br>0.37|**440V**<br>0.37|**500V**<br>0.37|**690V**<br>0.75|**Type Number**<br>PKE-XTUA-1,2|**Catalog Number**<br>**XTPEXTA1P2B**|
|1–4|XTPE012B|0.75|0.75|2|3|0.75|1.5|1.5|2.2|3|PKE-XTUA-4|**XTPEXTA004B**|
|3–12|XTPE012B|3|3|7.5|10|3|5.5|5.5|5.5|7.5|PKE-XTUA-12|**XTPEXTA012B**|
||XTPE032B||||||||||||
|8–32|XTPE032B|5|7.5|15|20|7.5|15|15|18.5|30|PKE-XTUA-32|**XTPEXTA032B**|
|8–32|XTPE065D|7.5|7.5|20|25|7.5|15|15|18.5|30|PKE-XTUWA-32|**XTPEXTA032D**|
|16–65|XTPE065D|15|15|40|40|18.5|30|37|45|55|PKE-XTUA-65|**XTPEXTA065D**|
## **D Frame**
## **MMP Complete Assembly**
||||||**IEC**|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
||**UL/CSA**||||**Maximum Motor kW Ratings**|**Maximum Motor kW Ratings**||||||
|**Overload**|**Maximum Three-Phase hp Ratings**|**Maximum Three-Phase hp Ratings**||**Maximum Three-Phase hp Ratings**|**220V**|**380V**||||**Complete Manual Motor Protector**|**Complete Manual Motor Protector**|
|**Release Setting**<br>**Amp Range**|**200V**|**240V**|**480V**|**600V**|**230V**<br>**240V**|**400V**<br>**415V**|**440V**|**500V**|**600V**<br>**690V**|**Type Number**|**Catalog Number**|
|0.3–1.2<br>1–4|1<br>0.75|1<br>0.75|0.5<br>2|0.5<br>3|0.18<br>0.75|0.37<br>1.5|0.37<br>1.5|0.37<br>2.2|0.75<br>3|PKE12/XTU-1,2<br>PKE12/XTU-4|**XTPE1P2BCS**<br>**XTPE004BCS**|
|3–12|3|3|7.5|10|3|5.5|5.5|5.5|7.5|PKE12/XTU-12|**XTPE012BCS**|
|8–32|5|7.5|15|20|7.5|15|15|18.5|30|PKE32/XTU-32|**XTPE032BCS**|
|8–32|7.5|7.5|20|25|7.5|15|15|18.5|30|PKE65/XTUW-32|**XTPE032DCS**|
|16–65|15|15|40|40|18.5|30|37|45|55|PKE65/XTU-65|**XTPE065DCS**|
_**Note**_
1 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6 (A) (1).
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-219**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **B Frame**
## **MMP Used with SmartWire-DT—Complete Assembly**
## **IEC**
|||||**IEC**|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Overload**|**UL/CSA**<br>**Maximum Motor hp Ratings**|**Maximum Motor hp Ratings**||**Maximum Motor kW Ratings**<br>**220V**|**Maximum Motor kW Ratings**<br>**380V**|**Maximum Motor kW Ratings**|||**Complete Manual Motor Protector**|**Complete Manual Motor Protector**|
|**Release Setting**<br>**Amp Range**<br>0.3–1.2<br>1–4<br>~~—~~<br>~~SSS~~|**200V**<br>1<br>0.75<br>~~SSS~~|**230V**<br>**460V**<br>1<br>0.5<br>0.75<br>2<br>~~SSS~~|**575V**<br>0.5<br>3<br>~~SSS~~|**230V**<br>**240V**<br>0.18<br>0.75<br>~~SSS~~|**400V**<br>**415V**<br>0.37<br>1.5<br>~~SSS~~|**440V**<br>0.37<br>1.5<br>~~SSS~~|**500V**<br>0.37<br>2.2<br>~~SSS~~|**600V**<br>**690V**<br>0.75<br>3<br>~~SSS~~|**Type Number**<br>PKE12/XTUA-1,2<br>PKE12/XTUA-4<br>~~SSS~~|**Catalog Number**<br>**XTPE1P2BCA**<br>**XTPE004BCA**<br>~~SSS~~|
|3–12|3|3<br>7.5|10|3|5.5|5.5|5.5|7.5|PKE12/XTUA-12|**XTPE012BCA**|
|8–32|5|7.5<br>15|20|7.5|15|15|18.5|30|PKE32/XTUA-32|**XTPE032BCA**|
## _**UL 508 Type E XT Electronic Combination Motor Controllers—Complete Assembly Including Trip Unit**_
## **B Frame**
## **B Frame Electronic MMP with C Frame Contactor**
## **UL/CSA**
||**UL/CSA**||||||||
|---|---|---|---|---|---|---|---|---|
|**Overload**|**Maximum Three-Phase hp Ratings**|**Maximum Three-Phase hp Ratings**||**Maximum Single-Phase hp Ratings**|**Maximum Single-Phase hp Ratings**|**Maximum Single-Phase hp Ratings**|||
|**Release Setting**<br>**Amp Range**<br>**Catalog Number**<br>**Standard**<br>**Catalog Number**<br>**With SmartWire-DT**<br>**200V**<br>**240V**<br>**380Y/**<br>**415V**<br>**480Y/**<br>**277V**<br>**600Y/**<br>**347V**<br>**115V**<br>**200V**<br>**240V**<br>0.3–1.2<br>1<br>1<br>1<br>1<br>0.5<br>1<br>1<br>1<br>**XTFCE1P2BCCS_**3<br>**XTFCE1P2BCCATD**3<br> ~~el~~|||||||||
|1–4|0.75<br>0.75<br>1.5|2|—|0.125|0.25|0.33|**XTFCE004BCCS_**4|**XTFCE004BCCATD**4|
|3–12|3<br>3<br>5|7.5|—|0.5|1|1.5|**XTFCE012BCCS_**4|**XTFCE012BCCATD**4|
|8–32|5<br>5<br>10|15|—|1.5|3|3|**XTFCE032BCCS_**4|**XTFCE032BCCATD**4|
## _**Notes**_
1 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6 (A) (1).
> 2 Complete the catalog number by replacing the underscore (_) with the coil suffix from **Page V5-T1-243** .
- 3 SCCR: 14 kA, 600 Vac
4 SCCR: 18 kA, 480 Vac
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-220**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Accessories**
## _**Auxiliary Contacts**_
## **XTPAXSA_**
**==> picture [311 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
Side-Mount Auxiliary Contacts<br>Contact Pkg. Screw Terminal<br>Configuration Contact Sequence Qty. [1] Catalog Number<br>1NO-1NC a 1.13 1.21 5 XTPAXSA11<br>L1 L2 L3<br>XTPAXSA11<br>oe<br>Ep |<br>| or. 1.14 1.22<br>1NO-2NC 1.13 1.21 1.31 5 XTPAXSA12<br>a L1 L2 L3 ne<br>XTPAXSA12 = Heo-4<br>i | sl<br>1.14 1.22 1.32<br>2NO-1NC [e} | 1.13 1.21 1.33 5 XTPAXSA21<br>i L1 L2 L3<br>XTPAXSA21<br>aee l| y |<br>1.14 1.22 1.34<br>**----- End of picture text -----**<br>
Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and XTPAXFA_ trip indicating auxiliary contact.
## **XTPAXFA11**
## **Front-Mount Auxiliary Contacts**
**Contact Pkg. Screw Terminal** —_— =i | **Configuration** 1NO-1NC ~~ee~~ **Contact Sequence** 1.53 1.61 5 **Qty.**[1] **Catalog NumberXTPAXFA11** ~~i~~ L1 L2 L3 ~~lee~~ XTPAXFA11 ~~Zs [|~~ ; 1 | ~~lie~~ | ~~{up~~ 1.54 1.62
Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR…B and XTPB) or 55 mm (XTPR…D) widths of manual motor protectors remain unchanged.
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-221**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **XTPAXSATR_**
## **Side-Mount Trip Indicating Auxiliary Contacts**
||**Contact**|||**Pkg.**|**For Use**||
|---|---|---|---|---|---|---|
||**Configuration**<br>2 x 1NO|**Contact Sequence**<br>4.44 4.14<br>“+”<br>4.43<br>“ ”<br>4.13<br>I><br>~~en~~<br>v~~e~~<br>~~--~~<br>**e** ~~ee~~<br>~~|~~<br>~~tek="+~~<br>~~_.~~||**Qty.**1<br>2|**with…**<br>XTPE|**Catalog Number**<br>**XTPAXSATR20**|
|||“+”<br>“>”<br>On/Off<br>“+”<br>“>”<br>Trip “+”<br>L1L2L3<br>L1L2L3<br>SE~~E~~<br>~~eel~~<br>~~fe}~~<br>|<br>~~a~~<br>~~ie~~<br>~~I =~~<br>~~—~~<br>~~fe}~~<br>~~|~~<br>~~rrTH~~<br>~~I~~<br>~~—|~~<br>~~Pty~~|||||
||||||||
|2 x 1NC||“+”<br>4.31<br>“ ”<br>4.21<br>I><br>~~en~~<br>~~HH~~<br>|<br>| ~~Le]~~ __<br>j ~~btiSk=44~~||2|XTPE|**XTPAXSATR02**|
|||4.32 4.22<br>On/Off|||||
|||L1L2L3<br>a~~n~~<br>~~el~~<br>~~fe}~~<br>||||||
|||“+”<br>~~—~Y~~|||||
|||“>”|||||
|||“+”<br>“>”<br>Trip “+”<br>L1L2L3<br>~~___§|_~~<br>~~@_ ———_—_—__~~<br>~~[e}~~<br>~~|~~<br>~~a~~<br>~~=~~<br>~~—lT~~|||||
Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable.
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-222**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Additional Accessories**_
**==> picture [504 x 291] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPAXSR_ Shunt Release XTPAXUVR_ Undervoltage Release<br>Pkg. Screw Terminal Pkg. Screw Terminal<br>‘ie Qty. (it [1] Catalog Number Qty. [1] Catalog Number<br>2 XTPAXSR24V50H 2 XTPAXUVR24V50H<br>2 XTPAXSR48V50H 2 XTPAXUVR24V60H<br>he a 2 XTPAXSR110V50H =k 2 TS XTPAXUVR48V50H<br>Contact Sequence 2 XTPAXSR120V60H Contact Sequence 2 XTPAXUVR60V50H<br>C1 2 XTPAXSR208V60H D1 2 XTPAXUVR110V50H<br>2 XTPAXSR220V50H 2 XTPAXUVR120V60H<br>2 XTPAXSR230V50H 2 XTPAXUVR208V60H<br>U<br>2 XTPAXSR240V50H 2 XTPAXUVR220V50H<br>C2 D2<br>2 XTPAXSR240V60H 2 XTPAXUVR230V50H<br>2 XTPAXSR380V50H 2 XTPAXUVR240V50H<br>2 XTPAXSR400V50H 2 XTPAXUVR240V60H<br>2 XTPAXSR415V50H 2 XTPAXUVR380V50H<br>2 XTPAXSR440V60H 2 XTPAXUVR400V50H<br>2 XTPAXSR480V60H 2 XTPAXUVR415V50H<br>2 XTPAXSR24VDC 2 XTPAXUVR440V60H<br>2 XTPAXSR48VDC 2 XTPAXUVR480V60H<br>2 XTPAXSR60VDC 2 XTPAXUVR600V60H<br>2 XTPAXSR110VDC Can be used to trip the manual motor protector from a remote<br>2 XTPAXSR125VDC location. Can be fitted on left side manual motor protectors.<br>2 XTPAXSR220VDC Cannot be combined with XTPAXSR. When combined with a<br>circuit breaker, it can be used as emergency-stop device to<br>2 XTPAXSR250VDC<br>**----- End of picture text -----**<br>
Can be used to trip the manual motor protector from a remote location. Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When combined with a circuit breaker, it can be used as emergency-stop device to IEC/EN 60204.
Can be used to trip the manual motor protector from a remote location. Can be fitted on the left side of manual motor protectors. Cannot be combined with the XTPAXUVR. DC: Intermittent operation 5 sec.
## _**Note**_
> 1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-223**
IEC Contactors and Starters
1.1
**1**
## _**XT**_ IEC Power Control
**IP65 Rotary Handle Mechanism**[123]
||||||**IP65 Rotary Handle Mechanism**[123]|
|---|---|---|---|---|---|
||||||**Enclosure**<br>**Pkg.**|
|**XTPAXRHM_**|||||**Description**<br>**Rating**<br>**Qty.**4<br>**Catalog Number**<br>**Complete Kits—Includes Handle, Shaft and Required Hardware**|
||||||Rotary handle mechanism—black5<br>IP65<br>NEMA 12<br>UL/CSA 4X<br>1<br>**XTPEXRHMB**<br>Rotary handle mechanism—red/yellow6<br>1<br>**XTPEXRHMRY**<br>Rotary handle mechanism—black—rotated 90° from vertical5<br>1<br>**XTPEXRHM90B**|
||||||Rotary handle mechanism—red/yellow—rotated 90° from vertical6<br>1<br>**XTPEXRHM90RY**|
||||||**Three-Phase Commoning Links**7<br>**Qty.**<br>**Length of**<br>**Unit**<br>**Pkg.**|
|**For Use with…**<br>**MMP**<br>**Link (mm)**<br>**Width (mm)**<br>**Qty.**4<br>**Catalog Number**<br>MMP with no side-mounted<br>auxiliaries or voltage releases<br>2<br>90<br>45<br>10<br>**XTPAXCLKA2**<br>3<br>135<br>45<br>10<br>**XTPAXCLKA3**<br>~~er~~<br>~~a~~||||||
|4<br>180<br>45<br>10<br>**XTPAXCLKA4**<br>~~SO~~||||||
||||||5<br>225<br>45<br>10<br>**XTPAXCLKA5**<br>~~a~~|
|med|||||Each MMP with one auxiliary<br>contact or trip-indicating auxiliary<br>2<br>99<br>45 + 9<br>10<br>**XTPAXCLKB2**|
|contact fitted on the right<br>3<br>153<br>45 + 9<br>10<br>**XTPAXCLKB3**<br>~~=~~||||||
|4<br>207<br>45 + 9<br>10<br>**XTPAXCLKB4**<br>~~Se~~||||||
|~~Se~~||||||
||||||5<br>261<br>45 + 9<br>10<br>**XTPAXCLKB5**|
|||||||
|Meme)|||||Each MMP with an auxiliary<br>contact and trip-indicating<br>2<br>108<br>45 + 18<br>10<br>**XTPAXCLKC2**|
||||||auxiliary contact mounted on<br>the right or a voltage release|
||||||mounted on the left.|
For parallel power feed to several manual motor protectors on terminals 1, 3 and 5.
**XTPAXUTS**
## **Shroud for Unused Terminals of Three-Phase Commoning Links**
|**XTPAXUTS**|**Shroud for Unused Terminals of Three-Phase Commoning Links**|**Shroud for Unused Terminals of Three-Phase Commoning Links**|
|---|---|---|
|||**Pkg.**|
|aS|**For Use with…**<br>Frame B<br>XTPE<br> ~~———___~~|**Description**<br>**Qty.**4<br>**Catalog Number**<br>To cover unused terminals on three-phase<br>commoning link. Protected against direct<br>contact.<br>20<br>**XTPAXUTS**<br>~~———___~~|
**XTPAXIT**
## **Incoming Terminals for Three-Phase**
**Commoning Link**[8]
|**Commoning Link**|**Commoning Link**[8]||
|---|---|---|
||**Pkg.**||
|**For Use with…**|**Qty.**4|**Catalog Number**|
|Frame B XTPE|5|**XTPAXIT**|
|**_Notes_**|||
- 1 Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 100–240 mm. Carrier with extension shaft included.
- 2 With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4–8 mm hasp. Can be locked in the OFF position, if required.
- 3 Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock.
- 4 Orders must be placed in multiples of package quantity listed.
- 5 For use on main switches to IEC/EN 60204.
- 6 For use on main switches with emergency-stop function to IEC/EN 60204.
- 7 Protected against accidental contact. Frame B short-circuit proof Ue = 690V, Iu = 63A. Frame B links can be combined by rotating mounting.
- 8 For three-phase commoning link, protected against accidental contact, Ue = 690V, Iu = 63A; For conductor cross-sections: 2.5–25 mm[2] stranded; 2.5–16 mm[2] flexible with ferrules, AWG 14-6.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-224**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Combination Connection Kits**_
|**TPCB**<br>**TPC_**<br>**EMCB**<br>**TPCRB**<br>**TPCRC**|**Non-Reversing Starters**<br>**For Use with…**<br>**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|**Non-Reversing Starters**<br>**For Use with…**<br>**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|**Non-Reversing Starters**<br>**For Use with…**<br>**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**|
|---|---|---|---|
||XTPE…B + XTCE…B||Mechanical connection element for XTPR…B and contactor<br>1<br>**XTPAXTPCB**<br>Main current wiring between XTPR…B and contactor in toolless plug connection<br>1<br>Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables<br>up to 2.5 mm2external diameter or four cables up to 3.5 mm2external diameter.|
||XTPR…B + XTCE…B||Mechanical connection element for XTPR…B and contactor<br>1<br>**XTPAXEMCB**<br>Main current wiring between XTPR…B and contactor screw in type connection<br>1|
||XTPR…B + XTCE…C||DIN rail adapter plate<br>Main current wiring between XTPR and contactor<br>1<br>**XTPAXTPCC**|
||**Reversing Starters**<br>**For Use with…**|**Description/Comprised of …**<br>**Std.**<br>**Pack**1<br>**Catalog Number**||
||XTPE…B + XTCE…B01_|Mechanical connection element for XTPR…B and contactor<br>1<br>**XTPAXTPCRB**<br>Reversing starter main current wiring in toolless plug connection<br>1<br>Control cables for electrical interlocking in toolless plug connection:<br>– K1M: A1–K2M: 21<br>– K1M: 21–K2M: A1<br>– K1M: A2–K2M: A2<br>1<br>Cable guidance<br>1<br>Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables<br>up to 2.5 mm2external diameter or four cables up to 3.5 mm2external diameter.||
||XTPE…B + XTCE…C|DIN rail adapter plate<br>1<br>**XTPAXTPCRC**<br>Reversing starter main current wiring<br>1||
||**_Note_**|||
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-225**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Electrical Connection Module**
**==> picture [36 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
XTPAXECM_<br>**----- End of picture text -----**<br>
|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**XTPAXECM_**|**Electrical Connection Module**|**Electrical Connection Module**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|a||||||||||||**For Use with…**<br>XTPE…B + XTCE…C|**Description/Comprised of …**<br>Main current wiring between XTPR…B and contactor|**Std.**<br>**Pack**1<br>5|**Catalog Number**<br>**XTPAXECMC**|
|||||||||||||**DIN Rail Adapter Plates**|**DIN Rail Adapter Plates**|||
|||||||||||||||**Std.**||
|||||||||||||**For Use with…**|**Description/Comprised of …**|**Pack**1|**Catalog Number**|
|**XTPAXTPCPB**||||||||||||XTPAXTPCB|45 mm wide adapter plate with one DIN rail|4|**XTPAXTPCPB**|
|||||||||||||XTPAXTPCRB|Connection element for side-by-side positioning of further plates|||
|||||||||||||||||
|||||||||||||||||
|**PKE-SWD-32**||||||||||||XTPE…B +|SmartWire-DT communication link|1|**PKE-SWD-32**|
|||||||||||||XTCE…B or C||||
## _**Note**_
1 Orders must be placed in multiples of package quantity listed.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-226**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Technical Data and Specifications**
_**XT**_ **Electronic Manual Motor Controllers**
|**Description**|**Specification**|**XTPE012B**<br>**XTPE032B**<br>**XTPE065D**|
|---|---|---|
|**General**|||
|Standards and regulations||IEC/EN 60947-4-1, VDE 0600, UL 508, CSA C 22.2 No. 14|
|Climatic proofing||Damp heat, constant, to IEC 60068-2-78|
|||Damp heat, cyclic, to IEC 60068-2-30|
|Ambient temperature<br>Storage||–40° to 80°C<br>–40° to 80°C<br>–40° to 80°C|
|Open||–25° to 55°C<br>–25° to 55°C<br>–25° to 55°C|
|Enclosed||–25° to 40°C<br>–25° to 40°C<br>–25° to 40°C|
|Direction of incoming supply||Any<br>Any<br>Any|
|Degree of protection|Device|IP20<br>IP20<br>IP20|
||Terminals|IP00<br>IP00<br>IP00|
|Touch protection<br>Mechanical shock resistance half-sinusoidal shock,<br>10 ms to IEC 60068-2-27||25g<br>25g<br>25g|
|Altitude||Max. 2000m<br>Max. 2000m<br>Max. 2000m|
|**Conductor Cross-Sections**|||
|Screw terminals|Solid|1 x (1–6) mm2<br>1 x (1–6) mm2<br>1 x (0.75–16) mm2|
|||2 x (1–6) mm2<br>2 x (1–6) mm2<br>2 x (0.75–16) mm2|
||Stranded with ferrule<br>to DIN 46228|1 x (1–6) mm2<br>1 x (1–6) mm2<br>1 x (0.75–35) mm2|
|||2 x (1–6) mm2<br>2 x (1–6) mm2<br>2 x (0.75–25) mm2|
||Solid or stranded|18–10 AWG<br>18–10 AWG<br>14–2 AWG|
|**Screw Terminal Tightening Torque**|||
|Main conductor||1.7 Nm<br>1.7 Nm<br>3.3 Nm|
|Auxiliary conductor||1 Nm<br>1 Nm<br>1 Nm|
|**Main Circuit**|||
|Rated impulse withstand voltage|Ump|6,000 Vac<br>6,000 Vac<br>6,000 Vac|
|Overvoltage category/pollution degree||III/3<br>III/3<br>III/3|
|Rated operational voltage|Ue|690V<br>690V<br>690V|
|Rated uninterrupted current = rated output current|Iu= Ie|12A<br>32A<br>65A|
|Rated frequency||40–60 Hz<br>40–60 Hz<br>40–60 Hz|
|Current heating losses (three-pole at operating<br>temperature)||6W<br>6W<br>6W|
|Lifespan, mechanical|Operations|0.05 x 106<br>0.05 x 106<br>0.05 x 106|
|Lifespan, electrical (AC-3 at 400V)|Operations|0.05 x 106<br>0.05 x 106<br>0.05 x 106|
|Maximum operating frequency|Operations/h|60<br>60<br>60|
|**Short-Circuit Rating**|||
|Motor switching capacity AC|AC-3 up to 690V|12A<br>32A<br>65A|
|**Trip Unit**|||
|Temperature compensation to IEC/EN 60947, VDE 0660||–5° to 40°C<br>–5° to 40°C<br>–5° to 40°C|
|Operating range||–25° to 55°C<br>–25° to 55°C<br>–25° to 55°C|
|Temperature compensation residual error for T >40°C||<<br>~~0~~.1%/K<br><<br>~~0~~.1%/K<br><<br>~~0~~.1%/K|
|Overload release setting range||0.25–1 xlu<br>0.25–1 xlu<br>0.25–1 xlu|
|Fixed short-circuit trip setting||12 x lr(trip unit),14 x lu(base)<br>12 x lr(trip unit),14 x lu(base)<br>12 x lr(trip unit),14 x lu(base)|
|Short circuit release tolerance||±20%<br>±20%<br>±20%|
|Phase failure sensitivity||Yes<br>Yes<br>Yes|
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-227**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Trip Characteristics**_
_**XT**_ **Electronic Manual Motor Controllers**
XTPE … RTT
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-228**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Dimensions**
Approximate Dimensions in Inches (mm)
_**XT**_ **Electronic MMP—B Frame**
**==> picture [172 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.77<br>3.79 (96.2)<br>(45.0)<br>3.98<br>(101.0)<br>4.72 (120.0)<br>**----- End of picture text -----**<br>
## _**XT**_ **Electronic MMP—D Frame**
**==> picture [244 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.65 (118.0)<br>1.28<br>(32.5)<br>2.22<br>6.30 (56.5)<br>(160.0)<br>0.57<br>(14.5)<br>0.22 (5.5)<br>5.00 (127.0)<br>1.38 2.17 6.77 (172.0)<br>(35.0) (55.0) 7.36 (187.0)<br>**----- End of picture text -----**<br>
## _**XT**_ **Electronic CMC With C Frame Contactor**
**==> picture [239 x 299] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.71 (145.0)<br>4.77 (121.2)<br>Line Side<br>3.66 (92.9)<br>Adapter To Line<br>Side Adapter<br>10.63<br>(269.9)<br>To Line<br>9.01 Side<br>(228.8) Adapter<br>9.46<br>(240.3)<br>1.76<br>(44.6)<br>Mounting<br>4.87 (123.8) Rail<br>**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-229**
1.1
_**XT**_ IEC Power Control
**1**
## IEC Contactors and Starters
## **EMS—Electronic Motor Starter**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-218**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-219**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-221**|
|Technical Data and Specifications . . . . . . . . . .|**V5-T1-227**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-229**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . .|**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## **EMS—Electronic Motor Starter**
## **Product Description**
The electronic motor starter (EMS) is the latest technology in safe and efficient motor starting from Eaton’s Electrical Sector. The EMS is a full starter with built-in solidstate contacts and integral overload protection. Its compact size and highelectrical life make it an ideal replacement for the traditional contactor/overload relay starter configuration.
## **Applications**
A versatile solution, the EMS also supports the following installation applications:
- Logistics
- Conveyer control
- Production machines
- Tooling machines
- Packaging machines
- Small elevators
## **Features and Benefits**
## _**Multifunctional**_
The EMS comes with an optional reversing start feature, eliminating the need for an additional contactor. The optional E-stop functionality eliminates the need for a separate E-stop contactor.
## _**Extended Life**_
High-electrical life provides up to 30 million operations. The EMS is ideal for customer applications requiring multiple motor start/stops per hour.
## **Standards and Certifications**
## _**Safety Rated**_
Functional safety is growing in importance for the machinery OEM. The EMS is rated at SIL3 per IEC 62061 and PLe per ISO[®] 13849, meeting the most stringent of safety requirements.
The EMS carries IEC and UL short-circuit ratings, with 100 kAIC UL short-circuit rating when mated with 30 A Class J fuse.
> ● UL
## _**Easy Installation**_
The EMS comes equipped with push-in terminals for quick and easy wiring of power and control circuits. Push-in terminals provide 60% time savings over screw-in terminals and better contact against vibrations.
_**Panel with four traditional starters installed:**_ **FVNR, FVR, FVNR with E-stop and FVR with E-stop**
_**Identical panel with four EMS starters installed, producing the same functionality**_
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-230**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
## **EMS—Electronic Motor Starter**
## **EMS ROS T 2.4 24VDC**
**==> picture [272 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
Device Type Control Voltage<br>EMS = Electronic motor starter 24VDC = 24 Vdc<br>SWD = SmartWire-DT<br>Configuration/Function Ampere Rating<br>DO = Non-reversing 2.4 = 2.4 A<br>DOS = Non-reversing with E-stop 9 = 9 A<br>RO = Reversing<br>ROS = Reversing with E-stop<br>**----- End of picture text -----**<br>
## **Product Selection**
**EMS-_**
## **EMS—Electronic Motor Starters**
|**Function**<br>Non-reversing<br>Reversing<br>Non-reversing, with E-stop<br>Reversing, with E-stop<br>Non-reversing<br>Reversing<br>Non-reversing, with E-stop<br>Reversing, with E-stop|**Current Range**<br>**AC-51a (A)**<br>0.18–2.4<br>0.18–2.4<br>0.18–2.4<br>0.18–2.4<br>1.5–9<br>1.5–9<br>1.5–9<br>1.5–9|**Current Range**<br>**AC-53a (A)**<br>0.18–2.4<br>0.18–2.4<br>0.18–2.4<br>0.18–2.4<br>1.5–6.5<br>1.5–6.5<br>1.5–6.5<br>1.5–6.5|**Motor Rating AC-53a**<br>**380 V, 400 V, 415 V (kW)**<br>0.06–0.75<br>0.06–0.75<br>0.06–0.75<br>0.06–0.75<br>0.55–3.0<br>0.55–3.0<br>0.55–3.0<br>0.55–3.0|**Catalog Number**<br>**EMS-DO-T-2.4-24VDC**<br>**EMS-RO-T-2.4-24VDC**<br>**EMS-DOS-T-2.4-24VDC**<br>**EMS-ROS-T-2.4-24VDC**<br>**EMS-DO-T-9-24VDC**<br>**EMS-RO-T-9-24VDC**<br>**EMS-DOS-T-9-24VDC**<br>**EMS-ROS-T-9-24VDC**<br>~~oo~~|
|---|---|---|---|---|
## **EMS with SmartWire-DT**
## **EMS-DOS-…,**
> **EMS-ROS-…** Electronic Motor Starters with SmartWire-DT built in do not require a separate module for connection to the SmartWire-DT network. Connection is made directly to the SmartWire-DT flat cable.
|for connection to the SmartWire-DT network. Connection is made directly to the<br>SmartWire-DT flat cable.<br>**Max. Equivalent hp Rating for Three-Phase**<br>**Motors, 60 Hz**<br>**Setting Range of**<br>**Overload Releases**<br>**Description**<br>**208 V**<br>**480 V**<br>**AC1**<br>**AC3**<br>DOL starting,<br>Motor protection,<br>For connecting to SmartWire-DT.<br>Circuit design: Safety output stage with bypass,<br>three-phase disconnect.<br>—<br>1<br>2.4<br>2.4<br>0.18–2.4<br>2<br>5<br>9.0<br>7.6<br>1.5–9<br>7 (AC–53a)<br>~~ce~~|for connection to the SmartWire-DT network. Connection is made directly to the<br>SmartWire-DT flat cable.<br>**Max. Equivalent hp Rating for Three-Phase**<br>**Motors, 60 Hz**<br>**Setting Range of**<br>**Overload Releases**<br>**Description**<br>**208 V**<br>**480 V**<br>**AC1**<br>**AC3**<br>DOL starting,<br>Motor protection,<br>For connecting to SmartWire-DT.<br>Circuit design: Safety output stage with bypass,<br>three-phase disconnect.<br>—<br>1<br>2.4<br>2.4<br>0.18–2.4<br>2<br>5<br>9.0<br>7.6<br>1.5–9<br>7 (AC–53a)<br>~~ce~~|for connection to the SmartWire-DT network. Connection is made directly to the<br>SmartWire-DT flat cable.<br>**Max. Equivalent hp Rating for Three-Phase**<br>**Motors, 60 Hz**<br>**Setting Range of**<br>**Overload Releases**<br>**Description**<br>**208 V**<br>**480 V**<br>**AC1**<br>**AC3**<br>DOL starting,<br>Motor protection,<br>For connecting to SmartWire-DT.<br>Circuit design: Safety output stage with bypass,<br>three-phase disconnect.<br>—<br>1<br>2.4<br>2.4<br>0.18–2.4<br>2<br>5<br>9.0<br>7.6<br>1.5–9<br>7 (AC–53a)<br>~~ce~~|for connection to the SmartWire-DT network. Connection is made directly to the<br>SmartWire-DT flat cable.<br>**Max. Equivalent hp Rating for Three-Phase**<br>**Motors, 60 Hz**<br>**Setting Range of**<br>**Overload Releases**<br>**Description**<br>**208 V**<br>**480 V**<br>**AC1**<br>**AC3**<br>DOL starting,<br>Motor protection,<br>For connecting to SmartWire-DT.<br>Circuit design: Safety output stage with bypass,<br>three-phase disconnect.<br>—<br>1<br>2.4<br>2.4<br>0.18–2.4<br>2<br>5<br>9.0<br>7.6<br>1.5–9<br>7 (AC–53a)<br>~~ce~~|for connection to the SmartWire-DT network. Connection is made directly to the<br>SmartWire-DT flat cable.<br>**Max. Equivalent hp Rating for Three-Phase**<br>**Motors, 60 Hz**<br>**Setting Range of**<br>**Overload Releases**<br>**Description**<br>**208 V**<br>**480 V**<br>**AC1**<br>**AC3**<br>DOL starting,<br>Motor protection,<br>For connecting to SmartWire-DT.<br>Circuit design: Safety output stage with bypass,<br>three-phase disconnect.<br>—<br>1<br>2.4<br>2.4<br>0.18–2.4<br>2<br>5<br>9.0<br>7.6<br>1.5–9<br>7 (AC–53a)<br>~~ce~~|**DC Operation**<br>**24 Vdc**<br>**Catalog Number**<br>**EMS-DO-T-2.4-SWD**<br>**EMS-DO-T-9-SWD**|
|---|---|---|---|---|---|
|DOL starting,<br>Motor protection,<br>Emergency-stop actuator.<br>Circuit design: Safety output stage with bypass,<br>three-phase disconnect.|—<br>1<br>2<br>5|2.4<br>9.0|2.4<br>7.6|0.18–2.4<br>1.5–9<br>7 (AC–53a)|**EMS-DOS-T-2.4-SWD**1<br>**EMS-DOS-T-9-SWD**1|
|DOL starting,<br>Reversing start,<br>Motor protection,<br>For connecting to SmartWire-DT.|—<br>1<br>2<br>5|2.4<br>9.0|2.4<br>7.6|0.18–2.4<br>1.5–9<br>7 (AC–53a)|**EMS-RO-T-2.4-SWD**<br>**EMS-RO-T-9-SWD**|
|Circuit design: Safety output stage with bypass,||||||
|three-phase disconnect.<br>DOL starting,|—<br>1|2.4|2.4|0.18–2.4|**EMS-ROS-T-2.4-SWD**1|
|Reversing start,<br>Motor protection,<br>Emergency-stop actuator.|2<br>5|9.0|7.6|1.5–9<br>7 (AC–53a)|**EMS-ROS-T-9-SWD**1|
|Circuit design: Safety output stage with bypass,<br>three-phase disconnect.||||||
## _**Note**_
1 EMS-DOS and EMS-ROS starters with emergency stop function have an additional terminal that needs to be connected to 0 V / 24 Vdc to provide an enable signal. (This is in addition to the SmartWire-DT signal.) Actuation of an E-stop will interrupt the 0 V / 24 Vdc connection and also override the SmartWire-DT signal.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-231**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**XT**_ **DC Contactors**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-3**|
|Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-18**|
|Contactors and Starters . . . . . . . . . . . . . . . . . . . .|**V5-T1-35**|
|Thermal Overload Relays . . . . . . . . . . . . . . . . . . .|**V5-T1-128**|
|C440/**_XT_**Electronic Overload Relay . . . . . . . . . . .|**V5-T1-141**|
|Manual Motor Protectors . . . . . . . . . . . . . . . . . . .|**V5-T1-157**|
|Combination Motor Controllers . . . . . . . . . . . . . . .|**V5-T1-191**|
|**_XT_**Electronic Manual Motor Protector||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V5-T1-218**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-219**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-221**|
|Technical Data and Specifications . . . . . . . . . .|**V5-T1-227**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-229**|
|EMS—Electronic Motor Starter . . . . . . . . . . . . . .|**V5-T1-230**|
|**_XT_**DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-232**|
|Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-234**|
## _**XT**_ **DC Contactors**
## **Product Description**
The _**XT**_ DC contactors for the current range 300 A to 600 A can be used in a variety of applications. The proven hybrid technology ensures a long life span of the devices. Compared to similar DC contactors, Eaton contactors are characterized by much higher electrical switching cycles. This makes the _**XT**_ DC contactors a maintenance- free and reliable part of any machine or system.
## **Application Description**
Best suited for a breadth of DC non-motor applications that require frequent switching or switching under load:
- Solar energy
- Energy storage
- Railway transportation
- Automotive infrastructure
- Marine and offshore DC
- DC-grids
- Testing equipment
## **Features and Benefits**
## _**Maintenance Free**_
The _**XT**_ DC contactors hybrid switching technology allows for nearly arc-free switching under load and an electrical life of 150,000 operations— the best in the industry by 6x. This feature greatly reduces maintenance cost while extending the life of the device.
## _**Reliable and Flexible**_
The contactors feature wide coil range and also direct PLC control, making them suitable for most systems. A wide temperature range of –40 °C to +70 °C allows them to handle any environment and their low coil consumption and switching energy means less heat output than standard DC contactors.
## **Standards and Certifications**
- CE approved
- UL Listed
- IEC/EN 60947-4-1, 60947-5-1
- CSA File 70044143
## _**Space Savings**_
The contactors are true two-pole units—they are compact, take up less space and do not require series wiring. They also allow bi-directional switching, meaning they are polarity independent.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-232**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Catalog Number Selection**
_**XT**_ **DC Contactors**
||||**XTCE**|**300**|**300**|**300**|**300**|**DCM**|**22**<br>**A**|**22**<br>**A**|**22**<br>**A**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Product Selection**<br>**Two-Pole Contactors, Frame M—UL/CSA Ratings**<br>**Designation**<br>**XTCE**=**_XT_**line of IEC contactors<br>**Current Ratings, DC-1**<br>**300**= 300 A<br>**400**= 400 A<br>**500**= 500 A<br>**600**= 600 A<br>**DC Frame Size**<br>**Designation**<br>**DCM**= 160 mm<br>**Built-In Auxiliary**<br>**Contact**<br>**22** = 2NO–2NC<br>**Coil Code**<br>**A** = 110–250 Vac 40–60 Hz<br>and 110–350 Vdc<br>and 24 Vdc PLC input<br>**Frame M DC**<br>~~=~~|||||||||||||||
|**Thermal Current (lth)**|||**Article**|||||**Auxiliary**|||||||
|**Ampere Rating**|||**Voltage**<br>**Number**|||||**Contacts**|**Catalog Number**1||||||
|300|||1000<br>183314|||||2NO–2NC|**XTCE300DCM22A**||||||
|400|||1000<br>186872|||||2NO–2NC|**XTCE400DCM22A**||||||
|500|||1000<br>186873|||||2NO–2NC|**XTCE500DCM22A**||||||
|600|||1000<br>183315|||||2NO–2NC|**XTCE600DCM22A**||||||
## _**Note**_
1 Does not include lugs.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-233**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Reference Data**
|**ference Data**||
|---|---|
|Type 2 Coordination . . . . . . . . . . . . . . . . . . . . . . .|**V5-T1-235**|
|Approvals for World Markets . . . . . . . . . . . . . . . .<br>IEC Utilization Categories . . . . . . . . . . . . . . . . . .|**V5-T1-244**<br>**V5-T1-247**|
|Motor Ratings Data . . . . . . . . . . . . . . . . . . . . . . .<br>Ampacities of Insulated Conductors|**V5-T1-250**|
|(Based on 2005 NEC) . . . . . . . . . . . . . . . . . . . .|**V5-T1-254**|
## **Type 1 and Type 2 Coordination**
## _**What is it?**_
The International Electrotechnical Commission (IEC) developed short-circuit performance criteria for contactors and starters called Type 1 coordination and Type 2 coordination. This defines motor controller protection levels following a short-circuit fault. In order to achieve this performance, the combination of a motor controller (contactor or starter) and short-circuit protective device (manual motor protector, circuit breaker or fuse) must meet the following criteria as specified by IEC 60947-4-1— Low voltage switchgear and controlgear—Part 4-1: Contactors and motorstarters—Electromechanical contactors and motorstarters:
## _**Type 1 Coordination**_
Type 1 Coordination requires that under short-circuit conditions, the contactor or starter shall cause no danger to persons or installation and may not be suitable for further service without repair and replacement of parts.
In this case, _significant damage is allowed_ to the contactor/starter (for example, contact welding, burning or disintegration) and the overload relay (for example, component harm or heater element burn-out).
## _**Type 2 Coordination**_
Type 2 Coordination requires that under short-circuit conditions, the contactor or starter shall cause no danger to persons or installation and shall be suitable for further use. The risk of contact welding is recognized, in which case the manufacturer shall indicate the measures to be taken as regards to the maintenance of the equipment.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-234**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Type 2 Coordination**
## **400, xx415V Type 2 Coordination—MMC**
|**P**<br>**(kW)**|**Ie**<br>**(A)**|**Iq**<br>**(kA)**|**MMP**<br>**Catalog Number**|**Contactor**<br>**Catalog Number**2|**MMC**<br>**Catalog Number**2|
|---|---|---|---|---|---|
|0.06|0.21|50 (150)1|XTPRP25BC1|XTCE007B10_|XTSCP25BB_|
|0.09<br>0.12|0.31<br>0.41|50 (150)1<br>50 (150)1|XTPRP40BC1<br>XTPRP63BC1|XTCE007B10_<br>XTCE007B10_|XTSCP40BB_<br>XTSCP63BB_|
|0.18|0.60|50 (150)1|XTPRP63BC1|XTCE007B10_|XTSCP63BB_|
|0.25|0.80|50 (150)1|XTPR001BC1|XTCE007B10_|XTSC001BB_|
|0.37|1.10|50 (150)1|XTPR1P6BC1|XTCE007B10_|XTSC1P6BB_|
|0.55<br>0.75|1.50<br>1.90|50 (150)1<br>50 (150)1|XTPR1P6BC1<br>XTPR2P5BC1|XTCE007B10_<br>XTCE007B10_|XTSC1P6BB_<br>XTSC2P5BB_|
|1.10|2.60|50 (150)1|XTPR004BC1|XTCE007B10_|XTSC004BB_|
|1.50|3.60|50 (150)1|XTPR004BC1|XTCE007B10_|XTSC004BB_|
|2.20|5.00|50 (150)1|XTPR6P3BC1|XTCE007B10_|XTSC6P3BB_|
|3.00|6.60|50 (150)1|XTPR010BC1|XTCE018C10_|XTSC010BC_|
|4.00|8.50|50 (150)1|XTPR010BC1|XTCE018C10_|XTSC010BC_|
|5.50<br>7.50|11.3<br>16.0|50<br>50|XTPR012BC1<br>XTPR016BC1|XTCE018C10_<br>XTCE018C10_|XTSC012BC_<br>XTSC016BC_|
|11.0|21.7|50|XTPR025BC1|XTCE025C10_|XTSC025BC_|
|15.0|29.3|50|XTPR032BC1|XTCE032C10_|XTSC032BC_|
|5.50|11.3|50|XTPR016DC1|XTCE018C10_|XTSC016DC_|
|7.50|16.0|50|XTPR016DC1|XTCE018C10_|XTSC016DC_|
|11.0|21.7|50|XTPR025DC1|XTCE025C10_|XTSC025DC_|
|15.0|29.3|50|XTPR032DC1|XTCE032C10_|XTSC032DC_|
|18.5|36.0|50|XTPR040DC1|XTCE040D00_|XTSC040DD_|
|22.0|41.0|50|XTPR050DC1|XTCE050D00_|XTSC050DD_|
|30.0|55.0|50|XTPR058DC1|XTCE065D00_|XTSC058DD_|
|34.0|63.0|50|XTPR063DC1|XTCE065D00_|XTSC063DD_|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
> 1 Values in parentheses ( ) are for Type 1 Coordination.
> 2 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-243** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-235**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **480V Type 2 Coordination—MMC**
|**P**<br>**(hp)**<br>1/2|**Ie**<br>**(A)**<br>0.24|**Iq**<br>**(kA)**<br>65|**MMP**<br>**Catalog Number**<br>XTPRP25BC1|**Current Limiter**<br>**Catalog Number**<br>—|**Contactor**<br>**Catalog Number**2<br>XTCE007B10_|**MMC**<br>**Catalog Number**2<br>XTSCP25BB_|
|---|---|---|---|---|---|---|
|1/2|0.32|65|XTPRP40BC1|—|XTCE007B10_|XTSCP40BB_|
|1/2|0.51|65|XTPRP63BC1|—|XTCE007B10_|XTSCP63BB_|
|1/2|0.74|65|XTPR001BC1|—|XTCE007B10_|XTSC001BB_|
|1/2|0.94|65|XTPR001BC1|—|XTCE007B10_|XTSC001BB_|
|3/4|1.32|65|XTPR1P6BC1|—|XTCE007B10_|XTSC1P6BB_|
|1|1.72|65|XTPR2P5BC1|—|XTCE018C10_|XTSC2P5BC_|
|2|2.55|65|XTPR004BC1|—|XTCE018C10_|XTSC004BC_|
|2<br>3|3.10<br>4.55|65<br>65 (50)1|XTPR004BC1<br>XTPR6P3BC1|—<br>XTPAXCL|XTCE018C10_<br>XTCE018C10_|XTSC004BC_<br>XTSC6P3BC_|
|3<br>7-1/2|6.15<br>8.40|65 (50)1<br>65 (50)1|XTPR6P3BC1<br>XTPR010BC1|XTPAXCL<br>XTPAXCL|XTCE018C10_<br>XTCE018C10_|XTSC6P3BC_<br>XTSC010BC_|
|7-1/2<br>10|11.0<br>14.5|65 (50)1<br>65 (50)1|XTPR012BC1<br>XTPR016BC1|XTPAXCL<br>XTPAXCL|XTCE018C10_<br>XTCE018C10_|XTSC012BC_<br>XTSC016BC_|
|10|20.0|65 (50)1|XTPR020BC1|XTPAXCL|XTCE025C10_|XTSC020BC_|
|20|20.0|65|XTPR025DC1|—|XTCE040D00_|XTSC025DD_|
|25|27.0|65|XTPR032DC1|—|XTCE040D00_|XTSC032DD_|
|25|32.0|65|XTPR032DC1|—|XTCE040D00_|XTSC032DD_|
|30|37.5|65|XTPR040DC1|—|XTCE040D00_|XTSC040DD_|
|40<br>40|40.5<br>50.5|65<br>65|XTPR050DC1<br>XTPR058DC1|—<br>—|XTCE050D00_<br>XTCE065D00_|XTSC050DD_<br>XTSC058DD_|
|40|64.0|65|XTPR063DC1|—|XTCE065D00_|XTSC063DD_|
## **600V Type 2 Coordination—MMC**
|**P**<br>**(hp)**<br>1/2|**Ie**<br>**(A)**<br>0.19|**Iq**<br>**(kA)**<br>50|**MMP**<br>**Catalog Number**<br>XTPRP25BC1|**Current Limiter**<br>**Catalog Number**<br>—|**Contactor**<br>**Catalog Number**2<br>XTCE007B10_|**MMC**<br>**Catalog Number**2<br>XTSCP25BB_|
|---|---|---|---|---|---|---|
|1/2|0.26|50|XTPRP40BC1|—|XTCE007B10_|XTSCP40BB_|
|1/2|0.41|50|XTPRP63BC1|—|XTCE007B10_|XTSCP63BB_|
|1/2|0.59|50|XTPRP63BC1|—|XTCE007B10_|XTSCP63BB_|
|1/2|0.75|50|XTPR001BC1|—|XTCE007B10_|XTSC001BB_|
|1|1.06|50|XTPR1P6BC1|—|XTCE007B10_|XTSC1P6BB_|
|1|1.38|50|XTPR1P6BC1|—|XTCE007B10_|XTSC1P6BB_|
|1-1/2|2.04|50|XTPR2P5BC1|—|XTCE018C10_|XTSC2P5BC_|
|1-1/2<br>3|2.48<br>3.64|50<br>50|XTPR2P5BC1<br>XTPR004BC1|—<br>—|XTCE018C10_<br>XTCE018C10_|XTSC2P5BC_<br>XTSC004BC_|
|5<br>10|4.92<br>6.72|50 (18)1<br>50 (18)1|XTPR6P3BC1<br>XTPR010BC1|XTPAXCL<br>XTPAXCL|XTCE018C10_<br>XTCE018C10_|XTSC6P3BC_<br>XTSC010BC_|
|10|8.60|50 (18)1|XTPR010BC1|XTPAXCL|XTCE018C10_|XTSC010BC_|
|10|11.5|50 (18)1|XTPR012BC1|XTPAXCL|XTCE018C10_|XTSC012BC_|
|10|16.0|50 (18)1|XTPR016BC1|XTPAXCL|XTCE018C10_|XTSC016BC_|
|25|21.5|50|XTPR025DC1|—|XTCE040D00_|XTSC025DD_|
|30|25.5|50|XTPR032DC1|—|XTCE040D00_|XTSC032DD_|
|30|30.0|50|XTPR032DC1|—|XTCE040D00_|XTSC032DD_|
|30|37.5|50|XTPR040DC1|—|XTCE040D00_|XTSC050DD_|
|40<br>40|40.5<br>51.0|50<br>42|XTPR050DC1<br>XTPR058DC1|—<br>—|XTCE050D00_<br>XTCE065D00_|XTSC050DD_<br>XTSC058DD_|
|50|61.0|42|XTPR063DC1|—|XTCE065D00_|XTSC063DD_|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
> 1 Values in parentheses ( ) are achieved without the current limiter.
> 2 Underscore (_) indicates magnet coil suffix required. See **Page V5-T1-243** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-236**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **400, 415V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect**
|**P**<br>**(kW)**<br>0.12|**Ie**<br>**(A)**<br>0.41|**Iq**<br>**(kA)**<br>100|**Fuses**<br>**Class**<br>2|**gG/gL**|**Contactor**<br>**Catalog Number**1<br>XTCE007B10_|**Overload Relay**<br>**Catalog Number**<br>XTOBP60BC1|**Assembled Starter**<br>**Catalog Number**1<br>XTAE007B10_P60|
|---|---|---|---|---|---|---|---|
|0.18|0.60|100|2||XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|0.25|0.80|100|4||XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|0.37|1.10|100|4||XTCE007B10_|XTOB1P6BC1|XTAE007B10_1P6|
|0.55|1.50|100|4||XTCE007B10_|XTOB1P6BC1|XTAE007B10_1P6|
|0.75|1.90|100|6||XTCE007B10_|XTOB2P4BC1|XTAE007B10_2P4|
|1.10|2.60|100|6||XTCE007B10_|XTOB004BC1|XTAE007B10_004|
|1.50|3.60|100|6||XTCE007B10_|XTOB004BC1|XTAE007B10_004|
|2.20|5.00|100|10||XTCE007B10_|XTOB006BC1|XTAE007B10_006|
|3.00|6.60|100|16||XTCE007B10_|XTOB010BC1|XTAE007B10_010|
|4.00|8.50|100|20||XTCE009B10_|XTOB010BC1|XTAE009B10_010|
|5.50<br>7.50|11.3<br>16.0|100<br>100|25<br>32||XTCE018C10_<br>XTCE018C10_|XTOB016CC1<br>XTOB016CC1|XTAE018C10_016<br>XTAE018C10_016|
|11.0|21.7|100|40||XTCE025C10_|XTOB024CC1|XTAE032C10_024|
|15.0|29.3|100|63||XTCE032C10_|XTOB032CC1|XTAE032C10_032|
|18.5|36.0|100|63||XTCE040D00_|XTOB040DC1|XTAE040D00_040|
|22.0|41.0|100|80||XTCE050D00_|XTOB057DC1|XTAE065D00_057|
|30.0|55.0|100|100||XTCE065D00_|XTOB057DC1|XTAE065D00_057|
|37.0<br>45.0|68.0<br>81.0|100<br>100|125<br>160||XTCE080F00_<br>XTCE095F00_|XTOB070GC1<br>XTOB100GC1|XTAE080F00_070<br>XTAE095F00_100|
|55.0|99.0|100|200||XTCE115G00_|XTOB100GC1|XTAE115G00_100|
|75.0|134.0|100|200||XTCE150G00_|XTOB150GC1|XTAE150G00_150|
|90.0|161.0|100|250||XTCE185L22_|XTOB220LC1|XTAE185L22_220|
|110.0|196.0|100|315||XTCE225L22_|XTOB220LC1|XTAE225L22_220|
|132.0|231.0|100|400||XTCE250L22_|XTOB250LC1|XTAE250L22_250|
|160.0<br>200.0|279.0<br>349.0|100<br>100|400<br>500||XTCE300M22_<br>XTCE400M22_|XTOT290C35<br>XTOT400C35|XTAE300M22_290<br>XTAE400M22_400|
|250.0|437.0|100|630||XTCE500M22_|XTOT540C35|XTAE500M22_540|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
> 1 Underscore (_) indicates magnet coil code required. See **Page V5-T1-243** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-237**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **500V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect**
|**1**<br>**1**|**500V**<br>**P**<br>**(kW)**<br>0.12|**Type**|**2**|**Coordinatio**<br>**Ie**<br>**(A)**<br>0.33|**n—Contactor**<br>**Iq**<br>**(kA)**<br>100|**and**|**Overload Relay**<br>**Fuses**<br>**Class gG/gL**<br>2|**(Motor Starter) with Fused Disconnect**<br>**Contactor**<br>**Catalog Number**1<br>**Overload Relay**<br>**Catalog Number**<br>XTCE007B10_<br>XTOBP40BC1|**(Motor Starter) with Fused Disconnect**<br>**Contactor**<br>**Catalog Number**1<br>**Overload Relay**<br>**Catalog Number**<br>XTCE007B10_<br>XTOBP40BC1|**Assembled Starter**<br>**Catalog Number**1<br>XTAE007B10_P40|
|---|---|---|---|---|---|---|---|---|---|---|
|**1**|0.18|||0.48|100||2|XTCE007B10_|XTOBP60BC1|XTAE007B10_P60|
||0.25|||0.70|100||2|XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|**1**|0.37|||0.90|100||2|XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|**1**|0.55<br>0.75|||1.20<br>1.50|100<br>100||4<br>4|XTCE007B10_<br>XTCE007B10_|XTOB1P6BC1<br>XTOB1P6BC1|XTAE007B10_1P6<br>XTAE007B10_1P6|
|**1**|1.10|||2.10|100||6|XTCE007B10_|XTOB2P4BC1|XTAE007B10_2P4|
||1.50|||2.90|100||6|XTCE007B10_|XTOB004BC1|XTAE007B10_004|
|**1**|2.20|||4.00|100||10|XTCE007B10_|XTOB006BC1|XTAE007B10_006|
||3.00|||5.30|100||16|XTCE009B10_|XTOB006BC1|XTAE009B10_006|
|**1**|4.00|||6.80|100||16|XTCE009B10_|XTOB010BC1|XTAE009B10_010|
|**1**|5.50<br>7.50|||9.00<br>12.1|100<br>100||20<br>25|XTCE012B10_<br>XTCE018C10_|XTOB010BC1<br>XTOB016CC1|XTAE012B10_010<br>XTAE018C10_016|
|**1**|11.0|||17.4|100||32|XTCE025C10_|XTOB024CC1|XTAE025C10_024|
||15.0|||23.4|100||50|XTCE040D00_|XTOB024DC1|XTAE040D00_024|
|**1**|18.5|||28.9|100||50|XTCE040D00_|XTOB040DC1|XTAE040D00_040|
||22.0|||33.0|100||63|XTCE050D00_|XTOB040DC1|XTAE050D00_040|
|**1**|30.0|||44.0|100||80|XTCE065D00_|XTOB057DC1|XTAE065D00_057|
|**1**|37.0<br>45.0|||54.0<br>65.0|100<br>100||100<br>125|XTCE080F00_<br>XTCE095F00_|XTOB070GC1<br>XTOB070GC1|XTAE080F00_070<br>XTAE095F00_070|
|**1**|55.0|||79.0|100||160|XTCE115G00_|XTOB100GC1|XTAE115G00_100|
||75.0|||107.0|100||200|XTCE185L22_|XTOB125LC1|XTAE185L22_125|
|**1**|90.0|||129.0|100||200|XTCE185L22_|XTOB125LC1|XTAE185L22_125|
|**1**|110.0<br>132.0|||157.0<br>184.0|100<br>100||250<br>250|XTCE185L22_<br>XTCE185L22_|XTOB160LC1<br>XTOB220LC1|XTAE185L22_160<br>XTAE185L22_220|
|**1**|160.0|||224.0|100||315|XTCE225L22_|XTOB250LC1|XTAE225L22_250|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
> 1 Underscore (_) indicates magnet coil code required. See **Page V5-T1-243** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-238**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**690V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect**
|**P**<br>**(kW)**<br>0.12|**Ie**<br>**(A)**<br>0.24|**Iq**<br>**(kA)**<br>100|**Fuses**<br>**Class**<br>1|**gG/gL**|**Contactor**<br>**Catalog Number**1<br>XTCE007B10_|**Overload Relay**<br>**Catalog Number**<br>XTOBP40BC1|**Assembled Starter**<br>**Catalog Number**1<br>XTAE007B10_P40|
|---|---|---|---|---|---|---|---|
|0.18|0.35|100|2||XTCE007B10_|XTOBP40BC1|XTAE007B10_P40|
|0.25|0.50|100|2||XTCE007B10_|XTOBP60BC1|XTAE007B10_P60|
|0.37|0.70|100|2||XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|0.55|0.90|100|4||XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|0.75|1.10|100|4||XTCE007B10_|XTOB1P6BC1|XTAE007B10_1P6|
|1.10|1.50|100|4||XTCE007B10_|XTOB1P6BC1|XTAE007B10_1P6|
|1.50|2.10|100|6||XTCE007B10_|XTOB2P4BC1|XTAE007B10_2P4|
|2.20|2.90|100|10||XTCE007B10_|XTOB004BC1|XTAE007B10_004|
|3.00|3.80|100|10||XTCE007B10_|XTOB004BC1|XTAE007B10_004|
|4.00|4.90|100|16||XTCE009B10_|XTOB006BC1|XTAE009B10_006|
|5.50<br>7.50|6.50<br>8.80|100<br>100|16<br>20||XTCE012B10_<br>XTCE018C10_|XTOB010BC1<br>XTOB010CC1|XTAE012B10_010<br>XTAE018C10_010|
|11.0|12.6|100|25||XTCE025C10_|XTOB016CC1|XTAE025C10_016|
|15.0|17.0|100|32||XTCE032C10_|XTOB024CC1|XTAE032C10_024|
|18.5|20.9|100|32||XTCE040D00_|XTOB024DC1|XTAE040D00_024|
|22.0|23.8|100|50||XTCE040D00_|XTOB040DC1|XTAE040D00_040|
|30.0|32.0|100|63||XTCE065D00_|XTOB040DC1|XTAE065D00_040|
|37.0<br>45.0|39.0<br>47.0|100<br>100|80<br>80||XTCE080F00_<br>XTCE080F00_|XTOB050GC1<br>XTOB050GC1|XTAE080F00_050<br>XTAE080F00_050|
|55.0|58.0|100|100||XTCE080F00_|XTOB070GC1|XTAE080F00_070|
|75.0|78.0|100|160||XTCE095F00_|XTOB100GC1|XTAE095F00_100|
|90.0|93.0|100|160||XTCE115G00_|XTOB100GC1|XTAE115G00_100|
|110.0|114.0|100|200||XTCE185L22_|XTOB125LC1|XTAE185L22_125|
|132.0|134.0|100|250||XTCE185L22_|XTOB160LC1|XTAE185L22_160|
|160.0|162.0|100|250||XTCE185L22_|XTOB220LC1|XTAE185L22_220|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications. 1 Underscore (_) indicates magnet coil code required. See **Page V5-T1-243** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-239**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
## **400, 415V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect**
|**1**<br>**1**|**400,**<br>**P**<br>**(kW)**<br>0.12|**415V**|**Type 2 Coordi**<br>**Ie**<br>**(A)**<br>0.41|**nation—Contactor**<br>**Iq**<br>**(kA)**<br>80|**and Overload**<br>**Fuses**1<br>**Class BS88**<br>4|**Relay (Motor Starter)**<br>**Contactor**<br>**Catalog Number**2<br>XTCE007B10_|**with Fused Disconnect**<br>**Overload Relay**<br>**Catalog Number**<br>XTOBP60BC1|**Assembled Starter**<br>**Catalog Number**2<br>XTAE007B10_P60|
|---|---|---|---|---|---|---|---|---|
|**1**|0.18||0.60|80|4|XTCE007B10_|XTOBP60BC1|XTAE007B10_P60|
||0.25||0.80|80|4|XTCE007B10_|XTOB001BC1|XTAE007B10_001|
|**1**|0.37||1.10|80|6|XTCE007B10_|XTOB1P6BC1|XTAE007B10_1P6|
|**1**|0.55<br>0.75||1.50<br>1.90|80<br>80|10<br>16|XTCE007B10_<br>XTCE007B10_|XTOB1P6BC1<br>XTOB2P4BC1|XTAE007B10_1P6<br>XTAE007B10_2P4|
|**1**|1.10||2.60|80|16|XTCE007B10_|XTOB004BC1|XTAE007B10_004|
||1.50||3.60|80|20|XTCE007B10_|XTOB004BC1|XTAE007B10_004|
|**1**|2.20||5.00|80|20|XTCE007B10_|XTOB006BC1|XTAE007B10_006|
||3.00||6.60|80|20|XTCE007B10_|XTOB010BC1|XTAE007B10_010|
|**1**|4.00||8.50|80|25|XTCE009B10_|XTOB010BC1|XTAE009B10_010|
|**1**|5.50<br>7.50||11.3<br>16.0|80<br>80|25<br>25|XTCE018C10_<br>XTCE018C10_|XTOB016CC1<br>XTOB016CC1|XTAE018C10_016<br>XTAE018C10_016|
|**1**|11.0||21.7|80|35 and 32M35|XTCE025C10_|XTOB024CC1|XTAE032C10_024|
||15.0||29.3|80|50|XTCE032C10_|XTOB032CC1|XTAE032C10_032|
|**1**|18.5||36.0|80|63|XTCE040D00_|XTOB040DC1|XTAE040D00_040|
||22.0||41.0|80|80|XTCE050D00_|XTOB057DC1|XTAE065D00_057|
|**1**|30.0||55.0|80|100|XTCE065D00_|XTOB065DC1|XTAE065D00_065|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
> 1 GEC/Alstom “Red Spot.”
> 2 Underscore (_) indicates magnet coil code required. See **Page V5-T1-243** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-240**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **400, 415V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Circuit Breaker**
|**P**<br>**(kW)**<br>0.12|**Ie**<br>**(A)**<br>0.41|**Iq**<br>**(kA)**<br>15|**Circuit**<br>**Breaker**<br>2|**Contactor**<br>**Catalog Number**1<br>2|**Overload Relay**<br>**Catalog Number**<br>2|**Assembled Starter**<br>**Catalog Number**1<br>2|
|---|---|---|---|---|---|---|
|0.18|0.60|15|2|2|2|2|
|0.25|0.80|15|2|2|2|2|
|0.37|1.10|15|2|2|2|2|
|0.55|1.50|15|2|2|2|2|
|0.75|1.90|15|2|2|2|2|
|1.10<br>1.50|2.60<br>3.60|15<br>15|2<br>2|2<br>2|2<br>2|2<br>2|
|2.20|5.00|15|2|2|2|2|
|3.00|6.60|15|2|2|2|2|
|4.00|8.50|15|HMCPE015E0C|XTCE018C10_|XTOB010CC1|XTAE018C10_010|
|5.50<br>7.50|11.3<br>16.0|15<br>15|HMCPE015E0C<br>2|XTCE018C10_<br>2|XTOB016CC1<br>2|XTAE018C10_016<br>2|
|11.0|21.7|15|2|2|2|2|
|15.0|29.3|15|2|2|2|2|
|18.5|36.0|50|2|2|2|2|
|22.0|41.0|50|HMCPE100R3C|XTCE050D00_|XTOB057DC1|XTAE050D00_057|
|30.0|55.0|50|HMCPE100R3C|XTCE065D00_|XTOB065DC1|XTAE065D00_065|
|37.0<br>45.0|68.0<br>81.0|80<br>80|HMCPJ250D5L<br>HMCPJ250F5L|XTCE080F00_<br>XTCE095F00_|XTOB070GC1<br>XTOB100GC1|XTAE080F00_070<br>XTAE095F00_100|
|55.0|99.0|80|HMCPJ250G5L|XTCE115G00_|XTOB125GC1|XTAE115G00_125|
|75.0|134.0|80|HMCPJ250J5L|XTCE150G00_|XTOB150GC1|XTAE150G00_150|
|90.0|161.0|80|HMCPJ250W5L|XTCE185L22_|XTOB220LC1|XTAE185L22_220|
|110.0|196.0|70|HMCPJ250W5L|XTCE225L22_|XTOB220LC1|XTAE225L22_220|
|132.0|231.0|70|HMCPL600R6G|XTCE300M22_|XTOT240C3S|XTAE300M22_240|
|160.0<br>200.0|279.0<br>349.0|70<br>70|HMCPL600X6G<br>HMCPL600P6G|XTCE300M22_<br>XTCE400M22_|XTOT400C3S<br>XTOT400C3S|XTAE300M22_400<br>XTAE400M22_400|
|250.0|430.0|70|HMCPL600M|XCE500M22_|XTOT540C3S|XTAE500M22_540|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
- 1 Underscore (_) indicates magnet coil code required. See **Page V5-T1-243** .
- 2 Use MMP contactor combination. See **Page V5-T1-235** .
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-241**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **525V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Circuit Breaker**
|**P**<br>**(kW)**<br>0.37|**Ie**<br>**(A)**<br>1.02|**Iq**<br>**(kA)**<br>50|**Circuit**<br>**Breaker**<br>2|**Contactor**<br>**Catalog Number**1<br>2|**Overload Relay**<br>**Catalog Number**<br>2|**Assembled Starter**<br>**Catalog Number**1<br>2|
|---|---|---|---|---|---|---|
|0.55|1.22|50|2|2|2|2|
|0.75|1.66|50|2|2|2|2|
|1.10|2.22|50|2|2|2|2|
|1.50|3.16|50|2|2|2|2|
|2.20|4.25|50|2|2|2|2|
|3.00<br>4.00|5.60<br>7.50|50<br>50|2<br>2|2<br>2|2<br>2|2<br>2|
|5.50|9.90|50|2|2|2|2|
|7.50|14.1|50|2|2|2|2|
|11.0|19.3|50|2|2|2|2|
|15.0<br>18.5|23.5<br>27.2|50<br>50|2<br>2|2<br>2|2<br>2|2<br>2|
|22.0|37.0|50|2|2|2|2|
|30.0|45.0|50|2|2|2|2|
|37.0|54.0|50|HMCP100R3C|XTCE080F00_|XTOB070GC1|XTAE080F00_070|
|45.0|66.0|50|HMCPJ250D5L|XTCE080F00_|XTOB070GC1|XTAE080F00_070|
|55.0|79.0|50|HMCPJ250F5L|XTCE115G00_|XTOB100GC1|XTAE115G00_100|
|75.0<br>90.0|111.0<br>130.0|50<br>50|HMCPJ250J5L<br>HMCPJ250K5L|XTCE115G00_<br>XTCE185L00_|XTOB125GC1<br>XTOB160LC1|XTAE115G00_125<br>XTAE185L00_160|
|110.0|159.0|50|HMCPJ250W5L|XTCE185L00_|XTOB160LC1|XTAE185L00_160|
|132.0|185.0|50|HMCPL600N6G|XTCE185L22_|XTOB220LC1|XTAE185L22_220|
|160.0|225.0|50|HMCPL600R6G|XTCE225L22_|XTOB250LC1|XTAE225L22_250|
|200.0|270.0|50|HMCPL600X6G|XTCE300M22_|XTOT290C3S|XTAE300M22_290|
## **480V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Circuit Breaker**
|**P**<br>**(hp)**|**Ie**<br>**(A)**|**Iq**<br>**(kA)**|**Circuit**<br>**Breaker**|**Contactor**<br>**Catalog Number**1|**Overload Relay**<br>**Catalog Number**|**Assembled Starter**<br>**Catalog Number**1|
|---|---|---|---|---|---|---|
|50.0<br>60.0|65.0<br>77.0|65<br>65|HMCPJ250D5L<br>HMCPJ250G5L|XTCE080F00_<br>XTCE080F00_|XTOB070GC1<br>XTOB100GC1|XTAE080F00_070<br>XTAE080F00_100|
|75.0|96.0|25|HMCPJ250J5L|XTCE115G00_|XTOB125GC1|XTAE115G00_125|
|100.0|124.0|50|HMCPJ250K5L|XTCE185L22_|XTOB160LC1|XTAE185L22_160|
|125.0|156.0|50|HMCPJ250W5L|XTCE185L22_|XTOB160LC1|XTAE185L22_160|
|150.0|180.0|25|HMCPL600N6G|XTCE225L22_|XTOB220LC1|XTAE225L22_220|
|200.0|240.0|50|HMCPL600N|XTCE300M22_|XTOB240C3S|XTAE300M22_240|
|250.0<br>300.0|290.0<br>361.0|50<br>50|HMCPL600R<br>HMCPL600Y|XTCE300M22_<br>XTCE400M22_|XTOB290C3S<br>XTOB400C3S|XTAE300M22_290<br>XTAE400M22_400|
|350.0|414.0|50|HMCPL600M|XTCE500M22_|XTOB540C3S|XTAE500M22_540|
## _**Notes**_
See **Page V5-T1-243** for more information on wye-delta (star delta) applications.
> 1 Underscore (_) indicates magnet coil code required. See **Page V5-T1-243** .
> 2 Use MMP contactor combination.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-242**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**400, 415V Type 2 Coordination—Contactor with Circuit Breaker**[1]
|**P**<br>**(kW)**|**Ie**<br>**(A)**|**Iq**<br>**(kA)**|**Circuit**<br>**Breaker—MCP**|**Contactor**<br>**Catalog Number**2|
|---|---|---|---|---|
|1.50|3.60|50|HMCPE015E0C|XTCE018C10_|
|2.20|5.00|50|HMCPE015E0C|XTCE018C10_|
|3.00|6.60|50|HMCPE015E0C|XTCE018C10_|
|4.00|8.50|50|HMCPE015E0C|XTCE018C10_|
|5.50|11.3|50|HMCPE015E0C|XTCE018C10_|
|7.50|16.0|50|HMCPE015E0C|XTCE018C10_|
|11.0|21.7|50|HMCPE100R3C|XTCE040D00_|
|15.0|29.3|50|HMCPE100R3C|XTCE040D00_|
|18.5|36.0|50|HMCPE100R3C|XTCE040D00_|
|22.0|41.0|50|HMCPE100R3C|XTCE050D00_|
|30.0|55.0|50|HMCPE100R3C|XTCE065D00_|
|37.0|68.0|80|HMCPJ250D5L|XTCE080F00_|
|45.0|81.0|80|HMCPJ250F5L|XTCE095F00_|
|55.0|99.0|80|HMCPJ250G5L|XTCE115G00_|
|75.0|134.0|80|HMCPJ250J5L|XTCE150G00_|
|90.0|161.0|80|HMCPJ250W5L|XTCE185L22_|
|110.0|196.0|80|HMCPJ250W5L|XTCE225L22_|
|132.0|231.0|70|HMCPL600R|XTCE300M22_|
|160.0|279.0|70|HMCPL600X|XTCE300M22_|
|200.0|350.0|70|HMCPL600P|XTCE400M22_|
|250.0|430.0|70|HMCPL600M|XTCE500M22_|
**480V Type 2 Coordination—Contactor with Circuit Breaker**[1]
|**P**<br>**(hp)**|**Ie**<br>**(A)**|**Iq**<br>**(kA)**|**Circuit**<br>**Breaker—MCP**|**Contactor**<br>**Catalog Number**2|
|---|---|---|---|---|
|50.0<br>60.0|65.0<br>77.0|65<br>65|HMCPJ250G5L<br>HMCPJ250G5L|XTCE080F00_<br>XTCE080F00_|
|150.0|180.0|50|HMCPL600N|XTCE300M00_|
|200.0|240.0|50|HMCPL600N|XTCE300M22__|
|250.0|300.0|50|HMCPL600R|XTCE300M22_|
|300.0|361.0|50|HMCPL600Y|XTCE400M00_|
|350.0|414.0|50|HMCPL600M|XTCE500M00_|
## _**Magnet Coil Suffix**_
## **Frames C–F**
## **Frames A–B**
|**Coil Voltage**<br>**Suffix Code**<br>110V 50 Hz, 120V 60 Hz<br>**A**<br>220V 50 Hz, 240V 60 Hz<br>**B**<br>230V 50 Hz<br>**F**<br>24V 50/60 Hz<br>**T**<br>24 Vdc<br>**TD** 3<br>415V 50 Hz, 480V 60 Hz<br>**C**<br>600V 60 Hz<br>**D**<br>208V 60 Hz<br>**E**<br>190V 50 Hz, 220V 60 Hz<br>**G**<br>240V 50 Hz, 277V 60 Hz<br>**H**<br>380V 50 Hz, 440V 60 Hz<br>**L**<br>400V 50 Hz<br>**N**<br>380V 60 Hz<br>**P**<br>12V 50/60 Hz<br>**R**<br>24V 50 Hz<br>**U**<br>42V 50 Hz, 48V 60 Hz<br>**W**<br>48V 50 Hz<br>**Y**<br>120 Vdc<br>**AD**3<br>220 Vdc<br>**BD**3<br>12 Vdc<br>**RD**3<br>48 Vdc<br>**WD**3|**Coil Voltage**<br>**Suffix Code**|
|---|---|
||110V 50 Hz, 120V 60 Hz<br>**A**|
||220V 50 Hz, 240V 60 Hz<br>**B**|
||230V 50 Hz<br>**F**|
||24V 50/60 Hz<br>**T**|
||24–27 Vdc<br>**TD**3|
||415V 50 Hz, 480V 60 Hz<br>**C**|
||600V 60 Hz<br>**D**|
||208V 60 Hz<br>**E**|
||190V 50 Hz, 220V 60 Hz<br>**G**|
||240V 50 Hz, 277V 60 Hz<br>**H**|
||380V 50 Hz, 440V 60 Hz<br>**L**|
||400V 50 Hz<br>**N**|
||380V 60 Hz<br>**P**|
||12V 50/60 Hz<br>**R**|
||24V 50 Hz<br>**U**|
||42V 50 Hz, 48V 60 Hz<br>**W**|
||48V 50 Hz<br>**Y**|
||110–130 Vdc<br>**AD** 3|
||200–240 Vdc<br>**BD** 3|
||12–14 Vdc<br>**RD** 3|
||48–60 Vdc<br>**WD** 3|
|**Frame G**<br>**Coil Voltage**<br>**Suffix Code**<br>100–120V 50/60 Hz<br>**A**<br>190–240V 50/60 Hz<br>**B**<br>24V 50/60 Hz<br>**T**<br>24–27 Vdc<br>**TD** 3<br>480–500V 50/60 Hz<br>**C**<br>380–440V 50/60 Hz<br>**L**<br>42–48V 50/60 Hz<br>**W**<br>110–130 Vdc<br>**AD** 3<br>200–240 Vdc<br>**BD** 3<br>48–60 Vdc<br>**WD** 3|**Frames L–M**<br>**Coil Voltage**<br>**Suffix Code**|
|---|---|
||110–250V 40–60 Hz/DC<br>**A**|
||250–500V 40–60 Hz/DC<br>**C**|
||48–110V 40–60 Hz/DC<br>**Y** 3|
||24–48 Vdc<br>**TD** 3|
|||
## _**Wye-Delta (Star-Delta) Applications**_
If Type 2 Coordination is protection, the K1M (main), required when using wyeK3M (star) and K5M (delta) delta starters, the full voltage contactors must all be the (direct on-line) test data that same size (amperage). For is included in this document wye-delta starter kits, please is valid. To ensure proper see **Page V5-T1-55** .
## _**Notes**_
- 1 For use with magnetic sensing means to monitor motor current.
- 2 Underscore (_) indicates magnet coil code required. See magnet coil suffix tables on this page.
- 3 With DC operation: integrated diode-resistor combination, coil rating 2.6W.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-243**
IEC Contactors and Starters
1.1
**Approvals for World Markets 1**
## _**XT**_ IEC Power Control
## _**Overview**_
The _**XT**_ line of products is approved for use throughout the world, including the USA and Canada. As such, they can be used without restriction as devices for world markets.
The majority of countries permit the import of devices on the manufacturer’s undertaking that they have been constructed in accordance with the pertinent specifications. In the USA and Canada, however, there is a legal obligation to obtain official approval. In these countries, devices and enclosures—sometimes even complete control systems—are tested and approved by independent bodies.
In Europe, there also used to be a legal obligation to obtain official approval for lowvoltage switchgear and controlgear. For industrial control gear, this legal obligation has now been abolished, provided the devices have been manufactured and tested in accordance with harmonized European standards (such as IEC/EN 60947). There is then no longer a requirement for them to carry their country’s own approval mark.
Since January 1997, all devices must conform to the European Low-Voltage Directive and, where intended for sale within the European Union, must carry the CE mark.
## **Europe**
Conformité Européen (CE)
This mark denotes that the device carrying it conforms to all relevant requirements and specifications. The mandatory application of this mark therefore enables the unrestricted use of marked devices within the European economic area.
Since January 1996, all devices sold within the European union must comply with the Electromagnetic Compatibility (EMC) Directive. _**XT**_ has passed the required tests to these Directives and the devices carry the CE mark, demonstrating compliance with the EMC Directive. _Because devices bearing the CE mark comply with the harmonized standards, approval and the associated marking is no longer required in the following countries:_
## **Belgium**
Comité Electrotechnique Belge Belgisch Elektrotechnisch Comité (CEBEC)
## **Denmark**
Danmarks Elektriske Materielkontrol (DEMKO)
**Finland** (FIMKO)
## **France**
Union Technique de l’Electricité (UTE)
## **Netherlands**
Naamloze Vennootschap tot Keuring van Electrotechnische Materialien (KEMA)
## **Norway**
Norges Elektriske Materiellkontrol (NEMKO)
## **Sweden**
Svenska Elektriska MaterielKontrollanstalten (SEMKO)
## **Switzerland**
Schweizerischer Elektrotechischer Verein (SEV)
Recently introduced is the mandatory approval of electrical products for:
- Slovakia
- Poland
- South Africa
- China
- Russia
- Turkey
- Argentina
Marking is partly mandatory for these countries. The IEC rating data is accepted as in other European countries.
Approval is not mandatory in the Czech Republic and Hungary. The manufacturer’s declaration of conformity is sufficient here.
Romania requires that components that are to be used in public buildings must be approved by the Romanian test authority ICECON.
## **Russia**
Devices for Russia must bear the appropriate marking.
## **Russia**
Goststandart (GOST-R)
**South Africa** ZA SABS
## **Argentina**
Devices in the USA and Canada have UL and CSA approval.
## _**Selection of Devices**_
## **USA**
Underwriters Laboratories (UL) **Listing**
**Recognition**
## **Canada**
Canadian Standards Association (CSA)
”Selection appropriate for export” does not mean merely meeting the requisite approvals and conformity to relevant specifications. The meaning of the term goes a great deal further by even including that equipment and installations must be designed to a concept with export in mind.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-244**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
The following are important criteria for selecting switchgear suitable for export:
## **For motor-protective circuit breakers**
## **For contactors**
## **For enclosures**
## **For overcurrent protective devices**
Use contactors whose entire range provides consistently reliable operation in the event of voltage drops (consistently down to 80% Un should be aimed for) and whose contact system will not assume an indeterminate position either on closing or on opening in such conditions.
Use insulated enclosures with transparent covers (that is, “totally insulated” enclosures).
Use inherently short-circuit proof switches capable of controlling the highest prospective fault levels at the point of installation without the need for backup protection.
Always use circuit breakers and motor-protective circuit breakers. Avoid fuses as much as possible.
## **Advantage:**
## **Advantage:**
## **Advantage:**
## **Advantage:**
- No restrictions whatsoever ● During electrification ● Total insulation is the best ● The operational reliability of for installation work in areas such as possible protective a system is especially
- ● Complete independence Africa and the Middle East, measure from the user’s important for export from the on-site protective an insufficient voltage point of view, avoiding contracts. Circuit breakers system stability is—at least for a reliance on the possibly and motor-protective circuit
- ● No problems getting certain time—likely in doubtful skills of unknown breakers provide this many applications (for installation personnel. reliability in full measure
- spare parts example due to long spur Furthermore, protective since they can be lines or small local measures based on immediately reclosed once generators). The use of earthing are often a fault has been cleared, devices that fulfill the extremely difficult, if not they disconnect all poles,
- **For circuit breakers** above requirements will impossible (in the Middle they have ideal protection Use types with visible eliminate one of the main East, for example, due to through high tripping contacts, quick-make and failure causes related to the dryness of the ground). accuracy and they can be quick-break operation as contactors. ● Insulated enclosures used for selective standard. Use current-limiting completely eliminate the operation. Because they circuit breakers for high shortneed for any additional have no fuses or other circuit levels. Selective protection against consumables, they also switches are recommended corrosion. The transparent greatly reduce the problem for the selective graduation covers contribute of obtaining replacement of networks. significantly to the correct parts. The advantages of operation of a system, fuseless design for export because switchgear are especially evident in operation can be this case. No complicated
- **Advantage:** monitored even with the investigation is needed to ● Independence from local doors or covers closed, find out which fusing accident prevention thus virtually eliminating system is used in the regulations requiring visible the possibility of these respective location and contacts and safety faults being left open through which specifications have caused by inexperienced carelessness. The to be followed to select the operating personnel. transparent cover is an correct fuses. Often several different fuse
- ● The effects of short-circuits important contribution to are kept to a minimum. safety, especially where systems with widely
- ● Fuseless installations exports to areas of uncertain skills are varying characteristics are used side-by-side in the offer greater safety and concerned. same country. For the reliability in plant operation. uninitiated, it may be In the event of a fault, only almost impossible to find the faulty section of the the right fuse in these system is isolated. circumstances. These problems do not arise where a circuit breaker is used.
## **For circuit breakers**
Use types with visible contacts, quick-make and quick-break operation as standard. Use current-limiting circuit breakers for high shortcircuit levels. Selective switches are recommended for the selective graduation of networks.
## **Advantage:**
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-245**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
## **For main switches and 1 safety switches**
Use devices with positive contact separation and clear switch position indication.
## **Advantage:**
- The mechanical coupling of the actuating element with the contacts ensues that the OFF position is indicated only when all main contacts are separated by the prescribed distance and only in this position can the switch be padlocked. This ensures safety when carrying out maintenance and repair work on the installation or machinery.
## _**Test Authorities**_
**USA** USA UL
## **Canada**
CDN CSA
## **Romania**
RO ICECON
## **Russia**
RUS GOST-R
## **South Africa**
ZA SABS
## **Slovakia**
SK SKTC
## **Poland**
PL BBJ-SEP
**Turkey** TR TSE
## _**Shipping Classifications**_
## **Germany**
Germanischer Lloyd (GL)
## **Great Britain**
Lloyd‘s Register of Shipping (LR)
## **France**
Bureau Veritas (BV) **Russia** Russian Maritime Register of Shipping (RS) **Italy** Registro Italiano Navale (RINA)
**Norway** Det Norske Veritas(DNV)
**Poland** Polski Rejestr Statkow (PRS)
## **China**
PRC CCC
**Ukraine** UA Ukrain-GOST
## _**Approvals for North America**_
In the U.S., the legally established OSHA (Occupational Safety and Health Act) and the NEC (National Electrical Code) require the use of approved devices and systems.
In Canada, all electrical apparatus must comply with the CEC (Canadian Electrical Code), which requires that all equipment and installations have CSA approval.
In addition to the normal UL and CSA approvals, the trade regulations originating from the NAFTA agreements allow the application for a joint UL and CSA approval. The devices then carry a logo that is recognized in both countries.
Some local inspectors and end users still refuse to accept the joint listing.
## **Approvals for North America**
**==> picture [212 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Type of Approval|Approval Mark|
|The device is UL- and CSA-approved as discrete device.|
|The device is CSA-approved as discrete device.|G|
|The device is UL-approved as discrete device.|
|The device contains UL-approved components; its approval|
|conditions must be maintained in use (UL Recognized). The|
|device is CSA-approved as discrete device.|
**----- End of picture text -----**<br>
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-246**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **IEC Utilization Categories**
(See also IEC/EN 60947-1; 2.1.18/IEV 441-17-19)
A combination of specified for example, relate to the requirements relating to the values of making and condition in which the breaking capacity and other switching device or fuse characteristic values, data fulfills its purpose and concerning associated selected to represent a circuits and the applicable characteristic group of conditions of use and real-life applications. The operational behavior. specified requirements may,
## **Used in Technical Data and Formula**
## **Code Description**
DF Duty factory IDn Response value of earth-fault release Icm Rated short-circuit making capacity Icn Rated short-circuit breaking capacity Ics Rated service short-circuit breaking capacity Icu Rated ultimate short-circuit breaking capacity Icw Rated short-time withstand current Ie Rated operational current Ik Transformer initial short-circuit AC current IL Load monitoring response value In Rated current INT Transformer rated current IPK Rated peak withstand current Iq Rated conditional short-circuit current Ir Overcurrent release set value Irm Response value of non-delayed short-circuit release Ii Response value of non-delayed short-circuit release Irmf Response value of fixed, non-delayed short-circuit release
## **Code Description**
Irmv Response value of short-time delayed short-circuit release Isd Response value of short-time delayed short-circuit release IT Response value of earth-fault release Ig Response value of earth-fault release Ith Conventional free air thermal current Ithe Conventional thermal current of enclosed devices Iu Rated uninterrupted current SNT Transformer rating tr Time delay of overload release response tT Time delay of earth-fault release response tg Time delay of earth-fault release response tv Time delay of short-circuit release response Uc Rated actuating voltage Ue Rated operational voltage Ui Rated insulation voltage Uimp Rated impulse withstand voltage Uk Transformer short-circuit voltage Us Rated control voltage
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-247**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Annex A (informative)**_
**Examples of Utilization Categories for Low Voltage Switchgear and Controlgear**[1]
|**Category**|**Typical Application**|**Relevant IEC Product Standard**|
|---|---|---|
|**Nature of**<br>AC-1|**Current—AC**<br>Non-inductive or slightly inductive loads, resistance furnaces|60947-4-1|
|AC-2|Slip-ring motors: starting, switching off|60947-4-1|
|AC-3|Squirrel cage motors: starting, switching off motors during running|60947-4-1|
|AC-4|Squirrel cage motors: starting, plugging2, inching3|60947-4-1|
|AC-5a<br>AC-5b|Switching of electric discharge lamp controls<br>Switching of incandescent lamps|60947-4-1<br>60947-4-1|
|AC-6a|Switching of transformers|60947-4-1|
|AC-6b|Switching of capacitor banks|60947-4-1|
|AC-7a|Slightly inductive loads for household appliances and similar applications|61095|
|AC-7b|Motor-loads for household applications|61095|
|AC-8a|Hermetic refrigerant compressor motor control with manual resetting of overload releases|60947-4-1|
|AC-8b<br>AC-12|Hermetic refrigerant compressor motor control with automatic resetting of overload releases<br>Control of resistive loads and solid-state loads with isolation by optocouplers|60947-4-1<br>60947-5-1|
|AC-12|Control of resistive loads and solid-state loads with optical isolation|60947-5-2|
|AC-13|Control of solid-state loads with transformer isolation|60947-5-1|
|AC-14|Control of small electromagnetic loads|60947-5-1|
|AC-15|Control of AC electromagnetic loads|60947-5-1|
|AC-20|Connecting and disconnecting under no-load conditions|60947-3|
|AC-21<br>AC-22|Switching of resistive loads, including moderate overloads<br>Switching of mixed resistive and inductive loads, including moderate overloads|60947-3<br>60947-3|
|AC-23|Switching of motor loads or other highly inductive loads|60947-3|
|AC-31|Non-inductive or slightly inductive loads|60947-6-1|
|AC-33|Motor loads or mixed loads including motors, resistive loads and up to 30% incandescent lamp loads|60947-6-1|
|AC-35<br>AC-36|Electric discharge lamp loads<br>Incandescent lamp loads|60947-6-1<br>60947-6-1|
|AC-40|Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive reactance|60947-6-2|
|AC-41|Non-inductive or slightly inductive loads, resistance furnaces|60947-6-2|
|AC-42|Slip-ring motors: starting, switching off|60947-6-2|
|AC-43|Squirrel cage motors: starting, switching off motors during running|60947-6-2|
|AC-44|Squirrel cage motors: starting, plugging2, inching3|60947-6-2|
|AC-45a<br>AC-45b|Switching of electric discharge lamp controls<br>Switching of incandescent lamps|60947-6-2<br>60947-6-2|
|AC-51|Non-inductive or slightly inductive loads, resistance furnaces|60947-4-3|
|AC-52a|Control of slip ring motor stators: 8 h duty with on-load currents for start, acceleration, run|60947-4-2|
|AC-52b|Control of slip ring motor stators: intermittent duty|60947-4-2|
|AC-53a|Control of squirrel cage motors: 8 h duty with on-load currents for start, acceleration, run|60947-4-2|
|AC-53b|Control of squirrel cage motors: intermittent duty|60947-4-2|
|AC-55a<br>AC-55b|Switching of electric discharge lamp controls<br>Switching of incandescent lamps|60947-4-3<br>60947-4-3|
|AC-56a|Switching of transformers|60947-4-3|
|AC-56b|Switching of capacitor banks|60947-4-3|
## _**Notes**_
> 1 60947-1 © IEC: 2004.
> 2 Plugging is stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running.
- 3 Inching (jogging) is energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-248**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
**Examples of Utilization Categories for Low-Voltage Switchgear and Controlgear, continued**[1]
|**Exampl**|**es of Utilization Categories for Low-Voltage Switchg**|**ear and Controlgear, continued**1||
|---|---|---|---|
|**Category**|**Typical Application**||**Relevant IEC Product Standard**|
|**Nature of**|**Current—AC, continued**|||
|AC-58a|Control of hermetic refrigerant compressor motors with automatic resetting of overload releases:||60947-4-2|
||h duty with on-load currents for start, acceleration, run|||
|AC-58b|Control of hermetic refrigerant compressor motors with automatic resetting of overload releases: intermittent duty||60947-4-2|
|AC-140|Control of small electromagnetic loads with holding (closed) current <<br>~~0~~,2 A, for example, contactor relays||60947-5-2|
|**Nature of**|**Current—AC and DC**|||
|A|Protection of circuits, with no rated short-time withstand current||60947-2|
|B|Protection of circuits, with a rated short-time withstand current||60947-2|
|**Nature of**|**Current—DC**|||
|DC-1|Non-inductive or slightly inductive loads, resistance furnaces||60947-4-1|
|DC-3|Shunt-motors: starting, plugging2, inching3, dynamic breaking of motors||60947-4-1|
|DC-5|Series-motors: starting, plugging2, inching3, dynamic breaking of motors||60947-4-1|
|DC-6<br>DC-12|Switching of incandescent lamps<br>Control of resistive loads and solid-state loads with isolation by optocouplers||60947-4-1<br>60947-5-1|
|DC-12|Control of resistive loads and solid-state loads with optical isolation||60947-5-2|
|DC-13|Control of electromagnets||60947-5-1|
|DC-13|Control of electromagnets||60947-5-2|
|DC-14|Control of electromagnetic loads having economy resistors in circuit||60947-5-1|
|DC-20|Connecting and disconnecting under no-load conditions||60947-3|
|DC-21<br>DC-22|Switching of resistive loads, including moderate overloads<br>Switching of mixed resistive and inductive loads, including moderate overloads (for example, shunt motors)||60947-3<br>60947-3|
|DC-23|Switching of motor loads or other highly inductive loads (for example,|series motors)|60947-3|
|DC-31|Resistive loads||60947-6-1|
|DC-33|Motor loads or mixed loads including motors||60947-6-1|
|DC-36<br>DC-40|Incandescent lamp loads<br>Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive reactance||60947-6-1<br>60947-6-2|
|DC-41<br>DC-43|Non-inductive or slightly inductive loads, resistance furnaces<br>Shunt-motors: starting, plugging2, inching3, dynamic breaking of DC||60947-6-2<br>60947-6-2|
|DC-45|Series-motors: starting, plugging2, inching3, dynamic breaking of DC||60947-6-2|
|DC-46|Switching of incandescent lamps||60947-6-2|
## _**Notes**_
- 1 60947-1 © IEC: 2004.
- 2 Plugging is stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running.
- 3 Inching (jogging) is energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-249**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Motor Ratings Data**
## _**Ampere Rating of AC and DC Motors**_
Ampere ratings of motors vary somewhat, depending upon the type of motor. The values given below are for drip-proof, Class B insulated (T Frame) where available, 1.15 service factor, NEMA Design B motors. These values represent an average full load motor current that was calculated from the motor performance data published by several motor manufacturers. In the case of high torque squirrel cage motors, the ampere ratings will be at least 10% greater than the values given below.
**Caution—These average ratings could be high or low for a specific motor and therefore heater coil selection on this basis always involves risk. For fully reliable motor protection, select heater coils on the basis of full load current rating as shown on the motor nameplate.**
## **Ampere Ratings of Three-Phase, 60 Hz, AC Induction Motor**
|**hp**|**Syn.**<br>**Speed**<br>**RPM**<br>**Current in Amperes**<br>**200V**<br>**230V**<br>**380V**1<br>**460V**<br>**575V**|
|---|---|
|1/4|1800<br>1.09<br>0.95<br>0.55<br>0.48<br>0.38|
||1200<br>1.61<br>1.40<br>0.81<br>0.70<br>0.56|
||900<br>1.84<br>1.60<br>0.93<br>0.80<br>0.64|
|1/3|1800<br>1.37<br>1.19<br>0.69<br>0.60<br>0.48|
||1200<br>1.83<br>1.59<br>0.92<br>0.80<br>0.64|
||900<br>2.07<br>1.80<br>1.04<br>0.90<br>0.72|
|1/2|1800<br>1.98<br>1.72<br>0.99<br>0.86<br>0.69|
||1200<br>2.47<br>2.15<br>1.24<br>1.08<br>0.86|
||900<br>2.74<br>2.38<br>1.38<br>1.19<br>0.95|
|3/4|1800<br>2.83<br>2.46<br>1.42<br>1.23<br>0.98|
||1200<br>3.36<br>2.92<br>1.69<br>1.46<br>1.17|
||900<br>3.75<br>3.26<br>1.88<br>1.63<br>1.30|
|1|3600<br>3.22<br>2.80<br>1.70<br>1.40<br>1.12|
||1800<br>4.09<br>3.56<br>2.06<br>1.78<br>1.42|
||1200<br>4.32<br>3.76<br>2.28<br>1.88<br>1.50|
||900<br>4.95<br>4.30<br>2.60<br>2.15<br>1.72|
|1-1/2|3600<br>5.01<br>4.36<br>2.64<br>2.18<br>1.74|
||1800<br>5.59<br>4.86<br>2.94<br>2.43<br>1.94|
||1200<br>6.07<br>5.28<br>3.20<br>2.64<br>2.11|
||900<br>6.44<br>5.60<br>3.39<br>2.80<br>2.24|
|2|3600<br>6.44<br>5.60<br>3.39<br>2.80<br>2.24|
||1800<br>7.36<br>6.40<br>3.87<br>3.20<br>2.56|
||1200<br>7.87<br>6.84<br>4.14<br>3.42<br>2.74|
||900<br>9.09<br>7.90<br>4.77<br>3.95<br>3.16|
|3|3600<br>9.59<br>8.34<br>5.02<br>4.17<br>3.34|
||1800<br>10.8<br>9.40<br>5.70<br>4.70<br>3.76|
||1200<br>11.7<br>10.2<br>6.20<br>5.12<br>4.10|
||900<br>13.1<br>11.4<br>6.90<br>5.70<br>4.55|
|5|3600<br>15.5<br>13.5<br>8.20<br>6.76<br>5.41|
||1800<br>16.6<br>14.4<br>8.74<br>7.21<br>5.78|
||1200<br>18.2<br>15.8<br>9.59<br>7.91<br>6.32|
||900<br>18.3<br>15.9<br>9.60<br>7.92<br>6.33|
|7-1/2|3600<br>22.4<br>19.5<br>11.8<br>9.79<br>7.81|
||1800<br>24.7<br>21.5<br>13.0<br>10.7<br>8.55|
||1200<br>25.1<br>21.8<br>13.2<br>10.9<br>8.70|
||900<br>26.5<br>23.0<br>13.9<br>11.5<br>9.19|
|10|3600<br>29.2<br>25.4<br>15.4<br>12.7<br>10.1|
||1800<br>30.8<br>26.8<br>16.3<br>13.4<br>10.7|
||1200<br>32.2<br>28.0<br>16.9<br>14.0<br>11.2|
||900<br>35.1<br>30.5<br>18.5<br>15.2<br>12.2|
## _**Note**_
> 1 380V 50 Hz.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-250**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## **Ampere Ratings of Three-Phase, 60 Hz, AC Induction Motor, continued**
|**hp**|**Syn.**<br>**Speed**<br>**RPM**<br>**Current in Amperes**<br>**200V**<br>**230V**<br>**380V**1<br>**460V**<br>**575V**<br>3600<br>41.9<br>36.4<br>22.0<br>18.2<br>14.5<br>1800<br>45.1<br>39.2<br>23.7<br>19.6<br>15.7<br>1200<br>47.6<br>41.4<br>25.0<br>20.7<br>16.5<br>900<br>51.2<br>44.5<br>26.9<br>22.2<br>17.8<br>3600<br>58.0<br>50.4<br>30.5<br>25.2<br>20.1<br>1800<br>58.9<br>51.2<br>31.0<br>25.6<br>20.5<br>1200<br>60.7<br>52.8<br>31.9<br>26.4<br>21.1<br>900<br>63.1<br>54.9<br>33.2<br>27.4<br>21.9<br>3600<br>69.9<br>60.8<br>36.8<br>30.4<br>24.3<br>1800<br>74.5<br>64.8<br>39.2<br>32.4<br>25.9<br>1200<br>75.4<br>65.6<br>39.6<br>32.8<br>26.2<br>900<br>77.4<br>67.3<br>40.7<br>33.7<br>27.0<br>3600<br>84.8<br>73.7<br>44.4<br>36.8<br>29.4<br>1800<br>86.9<br>75.6<br>45.7<br>37.8<br>30.2<br>1200<br>90.6<br>78.8<br>47.6<br>39.4<br>31.5<br>900<br>94.1<br>81.8<br>49.5<br>40.9<br>32.7<br>3600<br>111<br>96.4<br>58.2<br>48.2<br>38.5<br>1800<br>116<br>101<br>61.0<br>50.4<br>40.3<br>1200<br>117<br>102<br>61.2<br>50.6<br>40.4<br>900<br>121<br>105<br>63.2<br>52.2<br>41.7<br>3600<br>138<br>120<br>72.9<br>60.1<br>48.2<br>1800<br>143<br>124<br>75.2<br>62.2<br>49.7<br>1200<br>145<br>126<br>76.2<br>63.0<br>50.4<br>900<br>150<br>130<br>78.5<br>65.0<br>52.0<br>3600<br>164<br>143<br>86.8<br>71.7<br>57.3<br>1800<br>171<br>140<br>90.0<br>74.5<br>59.4<br>1200<br>173<br>150<br>91.0<br>75.0<br>60.0<br>900<br>177<br>154<br>93.1<br>77.0<br>61.5|**hp**|**Syn.**<br>**Speed**<br>**RPM**<br>**Current in Amperes**<br>**200V**<br>**230V**<br>**380V**1<br>**460V**<br>**575V**|
|---|---|---|---|
|15||75|3600<br>206<br>179<br>108<br>89.6<br>71.7|
||||1800<br>210<br>183<br>111<br>91.6<br>73.2|
||||1200<br>212<br>184<br>112<br>92.0<br>73.5|
||||900<br>222<br>193<br>117<br>96.5<br>77.5|
|20||100|3600<br>266<br>231<br>140<br>115<br>92.2|
||||1800<br>271<br>236<br>144<br>118<br>94.8|
||||1200<br>275<br>239<br>145<br>120<br>95.6|
||||900<br>290<br>252<br>153<br>126<br>101|
|25||125|3600<br>—<br>292<br>176<br>146<br>116|
||||1800<br>—<br>293<br>177<br>147<br>117|
||||1200<br>—<br>298<br>180<br>149<br>119|
||||900<br>—<br>305<br>186<br>153<br>122|
|30||150|3600<br>—<br>343<br>208<br>171<br>137|
||||1800<br>—<br>348<br>210<br>174<br>139|
||||1200<br>—<br>350<br>210<br>174<br>139|
||||900<br>—<br>365<br>211<br>183<br>146|
|40||200|3600<br>—<br>452<br>257<br>226<br>181|
||||1800<br>—<br>458<br>265<br>229<br>184|
||||1200<br>—<br>460<br>266<br>230<br>184|
||||900<br>—<br>482<br>279<br>241<br>193|
|50||250|3600<br>—<br>559<br>338<br>279<br>223|
||||1800<br>—<br>568<br>343<br>284<br>227|
||||1200<br>—<br>573<br>345<br>287<br>229|
||||900<br>—<br>600<br>347<br>300<br>240|
|60||300|1800<br>—<br>678<br>392<br>339<br>271|
||||1200<br>—<br>684<br>395<br>342<br>274|
|||400|1800<br>—<br>896<br>518<br>448<br>358|
|||500|1800<br>—<br>1110<br>642<br>555<br>444|
## _**Single-Phase AC Motors**_
The following values of fullload currents are for motors running at usual speeds and motors with normal torque characteristics. Motors built for especially low speeds or high torques may have higher full-load currents and multispeed motors will have full-load current varying with speed, in which case the nameplate current ratings shall be used.
The voltages listed are rated motor voltages. The currents listed shall be permitted for system voltage ranges of 110 to 120 and 220 to 240V.
## **Full-Load Currents in Amperes, Single-Phase Alternating-Current Motor**
|**hp**|**115V**|**200V**|**208V**|**230V**|
|---|---|---|---|---|
|1/6|4.4|2.5|2.4|2.2|
|1/4|5.8|3.3|3.2|2.9|
|1/3|7.2|4.1|4.0|3.6|
|1/2|9.8|5.6|5.4|4.9|
|3/4|13.8|7.9|7.6|6.9|
|1|16|9.2|8.8|8|
|1-1/2<br>2|20<br>24|11.5<br>13.8|11<br>13.2|10<br>12|
|3|34|19.6|18.7|17|
|5|56|32.2|30.8|28|
|7-1/2|80|46|44|40|
|10|100|57.5|55|50|
## _**Note**_
> 1 380V 50 Hz.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-251**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**Three-Phase AC Motors**_
The following values of fullload currents are typical for motors running at speeds usual for belted motors and motors with normal torque characteristics.
Motors built for low speeds (1,200 RPM or less) or high torques may require more running current and multispeed motors will have fullload current varying with speed. In these cases the nameplate current rating shall be used.
The voltages listed are rated motor voltages. The currents listed shall be permitted for system voltage ranges of 110 to 120, 220 to 240, 440 to 480 and 550 to 600V.
## **Full-Load Current Three-Phase Alternating-Current Motors**
||**Induction**|**Type Squirrel**|**Cage and Wound-Rotor**|**Amperes**|||**Synchronous**|**Type Unity Power Factor**1**Amperes**|**Type Unity Power Factor**1**Amperes**|
|---|---|---|---|---|---|---|---|---|---|
|**hp**|**115V**|**200V**|**208V**|**230V**|**460V**|**575V**|**230V**|**460V**|**575V**|
|1/2<br>3/4|4.4<br>6.4|2.5<br>3.7|2.4<br>3.5|2.2<br>3.2|1.1<br>1.6|.9<br>1.3|—<br>—|—<br>—|—<br>—|
|1|8.4|4.8|4.6|4.2|2.1|1.7|—|—|—|
|1-1/2|12.0|6.9|6.6|6.0|3.0|2.4|—|—|—|
|2|13.6|7.8|7.5|6.8|3.4|2.7|—|—|—|
|3|—|11.0|10.6|9.6|4.8|3.9|—|—|—|
|5|—|17.5|16.7|15.2|7.6|6.1|—|—|—|
|7-1/2<br>10|—<br>—|25.3<br>32.2|24.2<br>30.8|22<br>28|11<br>14|9<br>11|—<br>—|—<br>—|—<br>—|
|15|—|48.3|46.2|42|21|17|—|—|—|
|20|—|62.1|59.4|54|27|22|—|—|—|
|25|—|78.2|74.8|68|34|27|53|26|21|
|30|—|92|88|80|40|32|63|32|26|
|40|—|120|114|104|52|41|83|41|33|
|50<br>60|—<br>—|150<br>177|143<br>169|130<br>154|65<br>77|52<br>62|104<br>123|52<br>61|42<br>49|
|75|—|221|211|192|96|77|155|78|62|
|100|—|285|273|248|124|99|202|101|81|
|125|—|359|343|312|156|125|253|126|101|
|150<br>200|—<br>—|414<br>552|396<br>528|360<br>480|180<br>240|144<br>192|302<br>400|151<br>201|121<br>161|
|250|—|—|—|—|302|242|—|—|—|
|300|—|—|—|—|361|289|—|—|—|
|350|—|—|—|—|414|336|—|—|—|
|400|—|—|—|—|477|382|—|—|—|
|450|—|—|—|—|515|412|—|—|—|
|500|—|—|—|—|590|472|—|—|—|
_**Note**_
> 1 For 90 and 80 percent power factor, the above figures shall be multiplied by 1.1 and 1.25 respectively.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-252**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
## _**DC Motors**_
The following values of fullload currents are for motors running at base speed.
## **Full-Load Current in Amperes, Direct-Current Motors**
||||**Ampere Capacity of Fuses for Motors**|**Ampere Capacity of Fuses for Motors**|
|---|---|---|---|---|
|**hp**|**Armature**<br>**120V**|**Voltage Rating**1<br>**240V**|**Recommended Values**<br>**120V**<br>**240V**||
|1/4|3.1|1.6|5|3|
|1/3|4.1|2.0|5|3|
|1/2|5.4|2.7|7|3|
|3/4<br>1|7.6<br>9.5|3.8<br>4.7|10<br>15|5<br>7|
|1-1/2|13.2|6.6|20|10|
|2|17|8.5|25|12|
|3|25|12.2|30|15|
|5|40|20|50|25|
|7-1/2|58|29|80|40|
|10<br>15|76<br>—|38<br>55|100<br>—|50<br>75|
|20|—|72|—|100|
|25|—|89|—|125|
|30|—|106|—|150|
|40|—|140|—|200|
|50|—|173|—|250|
|60<br>75|—<br>—|206<br>255|—<br>—|275<br>350|
|100|—|341|—|500|
|125|—|425|—|600|
|150|—|506|—|—|
|200|—|675|—|—|
## _**Note**_
> 1 These are average direct-current quantities.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-253**
1.1
**1**
## IEC Contactors and Starters
## _**XT**_ IEC Power Control
## **Ampacities of Insulated Conductors (Based on 2005 NEC)**
_**Table 310.16.**_ **Allowable Ampacities of Insulated Conductors Rated 0–2000V, 60°–90°C [140°–194°F], Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C [86°F]**[1]
|**Size**<br>**AWG**<br>**kcmil**<br>**Temperature Rating of Conductor. See NEC Table 310-13.**<br>**Copper**<br>**60°C [140°F]**<br>**75°C [167°F]**<br>**90°C [194°F]**<br>**Types**<br>**TW**†**, UF** 2<br>**Types**<br>**FEPW** 2**, RH** 2**, RHW** 2**,**<br>**THHW** 2**, THW**2**,**<br>**THWN** 2**, XHHW** 2**,**<br>**USE** 2**, ZW** 2<br>**Types**<br>**TBS, SA, SIS, FEP** 2**, FEPB** 2**, MI,**<br>**RHH** 2**, RHW-2, THHN** 2**, THHW** 2**,**<br>**THW-2** 2**, THWN-2** 2**, USE-2,**<br>**XHH, XHHW** 2**, XHHW-2, ZW-2**<br>18<br>—<br>—<br>14<br>16<br>—<br>—<br>18<br>14<br>20✝<br>20✝<br>25†<br>12<br>25✝<br>25✝<br>30†<br>10<br>30<br>35✝<br>40†<br>8<br>40<br>50<br>55<br>6<br>55<br>65<br>75<br>70<br>85<br>95<br>55<br>85<br>100<br>110<br>65<br>95<br>115<br>130<br>75<br>110<br>130<br>150<br>85<br>1/0<br>125<br>150<br>170<br>2/0<br>145<br>175<br>195<br>3/0<br>165<br>200<br>225<br>4/0<br>195<br>230<br>260<br>250<br>215<br>255<br>290<br>300<br>240<br>285<br>320<br>350<br>260<br>310<br>350<br>400<br>280<br>335<br>380<br>500<br>320<br>380<br>430<br>600<br>355<br>420<br>475<br>700<br>385<br>460<br>520<br>750<br>400<br>475<br>535<br>800<br>410<br>490<br>555<br>600<br>355<br>420<br>475<br>700<br>385<br>460<br>520<br>750<br>400<br>475<br>535<br>800<br>410<br>490<br>555<br>900<br>435<br>520<br>585<br>1000<br>455<br>545<br>615<br>1250<br>495<br>590<br>665<br>1500<br>520<br>625<br>705<br>1750<br>545<br>650<br>735<br>2000<br>560<br>665<br>750|**Size**<br>**AWG**<br>**kcmil**<br>**Aluminum or Copper-Clad Aluminum**<br>**60°C [140°F]**<br>**75°C [167°F]**<br>**90°C [194°F]**<br>**Types**<br>**TW** 2**, UF** 2<br>**Types**<br>**RH** 2**, RHW** 2**,**<br>**THHW** 2**, THW** 2**,**<br>**THWN** 2**, XHHW** 2**,**<br>**USE** 2<br>**Types**<br>**TBS, SA, SIS, THHN** 2**,**<br>**THHW** 2**, THW-2, THWN-2,**<br>**RHH** 2**, RHW-2, USE-2, XHH,**<br>**XHHW, XHHW-2, ZW-2**|
|---|---|
||—<br>—<br>—<br>—|
||—<br>—<br>—<br>—|
||—<br>—<br>—<br>—|
||20†<br>20†<br>25†<br>12|
||25<br>30†<br>35†<br>10|
||30<br>40<br>45<br>8|
||40<br>50<br>60<br>6|
||65<br>75<br>4<br>70|
||75<br>85<br>3<br>85|
||90<br>100<br>2<br>95|
||100<br>115<br>1<br>110|
||100<br>120<br>135<br>1/0|
||115<br>135<br>150<br>2/0|
||130<br>155<br>175<br>3/0|
||150<br>180<br>205<br>4/0|
||170<br>205<br>230<br>250|
||190<br>230<br>255<br>300|
||210<br>250<br>280<br>350|
||225<br>270<br>305<br>400|
||260<br>310<br>350<br>500|
||285<br>340<br>385<br>600|
||310<br>375<br>420<br>700|
||320<br>385<br>435<br>750|
||330<br>395<br>450<br>800|
||285<br>340<br>385<br>600|
||310<br>375<br>420<br>700|
||320<br>385<br>435<br>750|
||330<br>395<br>450<br>800|
||355<br>425<br>480<br>900|
||375<br>445<br>500<br>1000|
||405<br>485<br>545<br>1250|
||435<br>520<br>585<br>1500|
||455<br>545<br>615<br>1750|
||470<br>560<br>630<br>2000|
## _**Notes**_
> 1 Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
> 2 Unless otherwise specifically permitted elsewhere in this _Code_ , the overcurrent protection for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No. 12 and 30A for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-254**
IEC Contactors and Starters
1.1
_**XT**_ IEC Power Control
**1**
_**Table 310.16.**_ **Allowable Ampacities of Insulated Conductors Rated 0–2000V, 60°–90°C [140°–194°F], Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C [86°F]—Correction Factors**[1]
## **Temperature Rating of Conductor. See NEC Table 310-13.**
|**Temperature Rating of Conductor. See NEC Table 310-13.**||
|---|---|
|**Size**<br>**AWG**<br>**kcmil**<br>**Copper**<br>**60°C [140°F]**<br>**75°C [167°F]**<br>**90°C [194°F]**<br>**Types**<br>**TW**†**, UF** 2<br>**Types**<br>**FEPW** 2**, RH** 2**, RHW** 2**,**<br>**THHW** 2**, THW**2**,**<br>**THWN** 2**, XHHW** 2**,**<br>**USE** 2**, ZW** 2<br>**Types**<br>**TBS, SA, SIS, FEP** 2**, FEPB** 2**, MI,**<br>**RHH** 2**, RHW-2, THHN** 2**, THHW** 2**,**<br>**THW-2** 2**, THWN-2** 2**, USE-2,**<br>**XHH, XHHW** 2**, XHHW-2, ZW-2**<br>**Ambient**<br>**Temp. °C**<br>**For Ambient Temperatures Other Than 30°C [86°F], Multiply the**<br>**Allowable Ampacities Shown in the Table on Page V5-T1-254**<br>**by the Appropriate Factor Shown Below**<br>21–25<br>1.08<br>1.05<br>1.04<br>26–30<br>1.00<br>1.00<br>1.00<br>31–35<br>0.91<br>0.94<br>0.96<br>36–40<br>0.82<br>0.88<br>0.91<br>41–45<br>0.71<br>0.82<br>0.87<br>46–50<br>0.58<br>0.75<br>0.82<br>51–55<br>0.41<br>0.67<br>0.76<br>56–60<br>—<br>0.58<br>0.71<br>61–70<br>—<br>0.33<br>0.58<br>71–80<br>—<br>—<br>0.41|**Aluminum or Copper-Clad Aluminum**<br>**Size**<br>**AWG**<br>**kcmil**<br>**60°C [140°F]**<br>**75°C [167°F]**<br>**90°C [194°F]**<br>**Types**<br>**TW** 2**, UF** 2<br>**Types**<br>**RH** 2**, RHW** 2**,**<br>**THHW** 2**, THW** 2**,**<br>**THWN** 2**, XHHW** 2**,**<br>**USE** 2<br>**Types**<br>**TBS, SA, SIS, THHN** 2**,**<br>**THHW** 2**, THW-2, THWN-2,**<br>**RHH** 2**, RHW-2, USE-2, XHH,**<br>**XHHW, XHHW-2, ZW-2**<br>**For Ambient Temperatures Other Than 30°C [86°F], Multiply the**<br>**Allowable Ampacities Shown in the Table on Page V5-T1-254**<br>**by the Appropriate Factor Shown Below**<br>**Ambient**<br>**Temp. °F**|
||1.08<br>1.05<br>1.04<br>70–77|
||1.00<br>1.00<br>1.00<br>78–86|
||0.91<br>0.94<br>0.96<br>87–95|
||0.82<br>0.88<br>0.91<br>96–104|
||0.71<br>0.82<br>0.87<br>105–113|
||0.58<br>0.75<br>0.82<br>114–122|
||0.41<br>0.67<br>0.76<br>123–131|
||—<br>0.58<br>0.71<br>132–140|
||—<br>0.33<br>0.58<br>141–158|
||—<br>—<br>0.41<br>159–176|
Where the number of current-carrying conductors in a raceway or cable exceeds three, the allowable ampacities shall be reduced as shown in the following table:
## _**Table 310.15 (B)(2)(a).**_ **Adjustment Factor for More Than Three Current-Carrying Conductors in Raceway or Cable**
|**Number of Current-Carrying**|**Percent of Values in Tables as Adjusted**|
|---|---|
|**Conductors**|**for Ambient Temperature if Necessary**|
|4–6|80|
|7–9|70|
|10–20<br>21–30|50<br>45|
|31–40|40|
|41 and above|35|
## _**Notes**_
- 1 Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
- 2 Unless otherwise specifically permitted elsewhere in this _Code_ , the overcurrent protection for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No. 12 and 30A for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copperclad aluminum after any correction factors for ambient temperature and number of conductors have been applied.
Where single conductors or multiconductor cables are stacked or bundled longer than 24 in (610 mm) without maintaining spacing and are not installed in raceways, the allowable ampacity of each conductor shall be reduced as shown in the above table.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-255**
IEC Contactors and Starters
1.1
## _**XT**_ IEC Power Control
**1**
_**Table 310.18.**_ **Allowable Ampacities of Three Single Insulated Conductors Rated 0–2000V, 150°–250°C [302°–482°F], in Raceway or Cable Based on Ambient Air Temperature of 40°C [104°F]**[1]
|**Size**|**Temperature Rating**<br>**150°C [302°F]**|**of Conductor. See NEC Table 310-13.**<br>**200°C [392°F]**|**250°C [482°F]**|**150°C [302°F]**|**Size**|
|---|---|---|---|---|---|
|**AWG**<br>**kcmil**|**Type Z**<br>**Copper**|**Types FEP, FEPB, PFA**|**Types PFAH, TFE**<br>**Nickel or Nickel-Coated Copper**|**Type Z**<br>**Aluminum or Copper-Clad Aluminum**|**AWG**<br>**kcmil**|
|14|34|36|39|—|14|
|12|43|45|54|30|12|
|10|55|60|73|44|10|
|8|76|83|93|57|8|
|6|96|110|117|75|6|
|4<br>3|120<br>143|125<br>152|148<br>166|94<br>109|4<br>3|
|2|160|171|191|124|2|
|1|186|197|215|145|1|
|1/0|215|229|244|169|1/0|
|2/0|251|260|273|198|2/0|
|3/0|288|297|308|227|3/|
|4/0|332|346|361|260|4/0|
|250|—|—|—|—|250|
|300|—|—|—|—|300|
|350|—|—|—|—|350|
|400|—|—|—|—|400|
|500<br>600|—<br>—|—<br>—|—<br>—|—<br>—|500<br>600|
|700|—|—|—|—|700|
|750|—|—|—|—|750|
|800|—|—|—|—|800|
|1000|—|—|—|—|1000|
|1500|—|—|—|—|1500|
|2000|—|—|—|—|2000|
|**Correction**|**Factors**|||||
|**Ambient**|||||**Ambient**|
|**Temp. °C**|**For Ambient Temperatures Other Than 40°C [104°F], Multiply the Allowable Ampacities Shown Above By the Appropriate Factor Shown Below**||||**Temp. °F**|
|41–50|0.95|0.97|0.98|0.95|105–122|
|51–60<br>61–70|0.90<br>0.85|0.94<br>0.90|0.95<br>0.93|0.90<br>0.85|123–140<br>141–158|
|71–80|0.80|0.87|0.90|0.80|159–176|
|81–90|0.74|0.83|0.87|0.74|177–194|
|91–100|0.67|0.79|0.85|0.67|195–212|
|101–120|0.52|0.71|0.79|0.52|213–248|
|121–140|0.30|0.61|0.72|0.30|249–284|
|141–160|—|0.50|0.65|—|285–320|
|161–180|—|0.35|0.58|—|321–356|
|181–200|—|—|0.49|—|357–392|
|201–225|—|—|0.35|—|393–437|
## _**Note**_
> 1 Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
**Volume 5—Motor Control and Protection** CA08100006E—April 2017 www.eaton.com
**V5-T1-256**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →