Image not available
Illustrative purposes only
XMLR250M2P05
Pressure Sensor, 250 bar, PNP, Differential, 24 VDC, G1/4 (1/4
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TELEMECANIQUE SENSORS
- Product type: Pressure Transducers
- Port Style: G1/4 (1/4" BSP)
- Product Range: OsiSense XM Series
- Sensor Output: PNP
- Supply Current: 50mA
- Voltage Rating: 24VDC
- Operating Pressure Max: 250bar
- Pressure Measurement Type: Differential
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 281.01 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product data sheet Characteristics ## XMLR250M2P05 Pressure sensors XMLR 250bar - G 1/4 - 24VDC - 2xPNP - M12 ## Main |Main|Main|| |---|---|---| |Range of product<br>Product or component<br>~~ee~~||OsiSense XM<br>Electronic pressure sensors| ||type<br>Pressure sensor type<br>Pressure transmitter<br>~~a~~|| ||Pressure switch type of|Pressure switch with 2 switching outputs| ||operation|| ||Device short name|XMLR| ||Pressure sensor size|3620 Psi (24959.02 kPa)| |||3625.94 psi (250 bar)| ||Maximum permissible|10877.83 Psi (750 bar)| ||accidental pressure|75 MPa| ||Destruction pressure<br>Controlled fluid<br>Fluid connection type<br>[Us] rated supply<br>voltage|10875 psi (74980.48 kPa)<br>150 MPa<br>21750 Psi (149960.96 kPa)<br>21755.66 psi (1500 bar)<br>Fresh water 32…176 °F (0…80 °C))<br>Air -4…176 °F (-20…80 °C))<br>Hydraulic oil -4…176 °F (-20…80 °C))<br>Refrigeration fluid -4…176 °F (-20…80 °C))<br>G 1/4 (female) DIN 3852-Y<br>24 V DC SELV 17…33 V)| |Complementary<br>Current consumption<br>Electrical connection<br>Type of output signal<br>Discrete output type<br>Maximum switching current<br>Contacts type and composition<br>Scale type<br>Maximum voltage drop<br>Adjustable range of switching point on rising<br>pressure<br>Adjustable range of switching point on falling<br>pressure<br>Minimum differential travel<br>Materials in contact with fluid<br>Front material<br>Housing material<br>Operating position<br>Protection type<br>Response time on output<br>Switching output time delay<br>Display type|<= 50 mA<br>Male connector M12, 4 pins<br>Discrete<br>Solid state PNP, 2 NO/NC programmable<br>250 mA<br>2 NO/NC programmable<br>Fixed differential<br>2 V<br>290…3625 Psi (1999.48…24993.49 kPa)<br>290.08…3625.94 Psi (20…250 bar)<br>2…25 MPa<br>181.30…3509.91 Psi (12.5…242 bar)<br>1.25…24.2 MPa<br>181…3516 psi (1247.95…24241.97 kPa)<br>108.78 Psi (7.5 bar)<br>0.75 MPa<br>109 psi (751.53 kPa)<br>316L stainless steel<br>Polyester<br>Polyacrylamide<br>316L stainless steel<br>Any position, but disposals can falsified the measurement in case of upside down<br>mounting<br>Short-circuit protection<br>Overvoltage protection<br>Overload protection<br>Reverse polarity<br><= 5 ms discrete output<br>0...50 s in steps of 1 second<br>4 digits 7 segments| |---|---| Jan 20, 2021 1 |Local signalling|Light ON when switch is actuated 2 LEDs yellow)| |---|---| |Display response time type|Fast 50 ms| ||Normal 200 ms| ||Slow 600 ms| |Maximum delay first up|300 ms| |Overall accuracy|<= 1 % of the measuring range| |Measurement accuracy on switching output|<= 0.6 % of the measuring range| |Repeat accuracy|<= 0.2 % of the measuring range| |Drift of the sensitivity|+/- 0.03 % of measuring range/°C| |Drift of the zero point|+/- 0.1 % of measuring range/°C| |Display accuracy|<= 1 % of the measuring range| |Mechanical durability|10000000 cycles| |Depth|1.65 in (42 mm)| |Height|3.46 in (88 mm)| |Width|1.61 in (41 mm)| |Net weight|0.41 lb(US) (0.186 kg)| |[Uimp] rated impulse withstand voltage|0.5 kV DC| |Electromagnetic compatibility|Susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3| ||Immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6| ||Surge immunity test 1 kV EN/IEC 61000-4-5| ||Electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4| ||Electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2| ## Environment |Environment|| |---|---| |Marking|CE| |Product certifications|CULus| ||EAC| |Standards|EN/IEC 61326-2-3| ||UL 61010-1| |Ambient air temperature for operation|-4…176 °F (-20…80 °C)| |Ambient air temperature for storage|-40…176 °F (-40…80 °C)| |IP degree of protection|IP65 EN/IEC 60529| ||IP67 conforming to EN/IEC 60529| |Vibration resistance|20 gn 10…2000 Hz)EN/IEC 60068-2-6| |Shock resistance|50 gn EN/IEC 60068-2-27| ## Ordering and shipping details |Ordering and shipping detailsg and shipping detailsand shipping detailspping detailsing detailsg detailsdetails|| |---|---| |Category|21551 - XMLE,XMLF,XMLG PRESSURE SENSORS| |Discount Schedule|DS2| |GTIN|03389119611640| |Nbr. of units in pkg.|1| |Package weight(Lbs)|0.41 lb(US) (0.19 kg)| |Returnability|No| |Country of origin|CH| ## Packing Units |Packing Unitsg UnitsUnits|| |---|---| |Unit Type of Package 1|PCE| |Package 1 Height|2.91 in (7.4 cm)| |Package 1 width|5.12 in (13 cm)| |Package 1 Length|2.60 in (6.6 cm)| |Unit Type of Package 2|S02| |Number of Units in Package 2|20| |Package 2 Weight|8.86 lb(US) (4.02 kg)| |Package 2 Height|5.91 in (15 cm)| |Package 2 width|11.81 in (30 cm)| |Package 2 Length|15.75 in (40 cm)| 2 |Offer Sustainability|||| |---|---|---|---| |California proposition 65|WARNING: This product can expose you to chemicals including: Diisononyl||WARNING: This product can expose you to chemicals including: Diisononyl| ||phthalate (DINP), which is known to the State of California to cause cancer,||| ||and Di-isodecyl phthalate (DIDP), which is known to the State of California||and Di-isodecyl phthalate (DIDP), which is known to the State of California| ||to cause birth defects or other reproductive harm. For more information go to||| ||www.P65Warnings.ca.gov||| |REACh Regulation|REACh Declaration<br>Ee||| |REACh free of SVHC|Yes||| |EU RoHS Directive|Pro-active compliance (Product out of EU RoHS legal scope)|iy|EU RoHS| ||Declaration||| |Mercury free|Yes||| |RoHS exemption information|Yes<br>Ee||| 3 Product data sheet Dimensions Drawings ## XMLR250M2P05 ## Dimensions (1) Fluid entry: G 1/4 A female 4 Product data sheet Connections and Schema ## XMLR250M2P05 ## Connections and Schema ## Connector Wiring 5 Product data sheet Performance Curves ## XMLR250M2P05 ## Switching Output Description. Hysteresis Mode The hysteresis switching mode is typically used for the “pumping and/or emptying applications”. - X : Time Y : Pressure (1) Output NP : Nominal Pressure SP : Set point (adjustable from 8 % to 100 % NP) - rP : Reset point (adjustable from 5 % to 97 % NP) ## Switching Output Description. Window Mode The window switching mode is typically used for the “pressure regulation applications” X : Time Y : Pressure (1) Output NP : Nominal pressure FH : High switching point (adjustable from 8 % to 100 % NP) FL : Low switching point (adjustable from 5 % to 97 % NP) ## Switching Output Description. Time Delay The Time Delay is typically used to filter out the fast pressure transients. The output only switches after a time “dS” and “dr” adjustable from 0 to 50 seconds. 6 X : Time Y : Pressure (1) Output SP : Set point rP : Reset point dS : Time delay on the set point dr : Time delay on the reset point 7
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →