Image not available
Illustrative purposes only
XDR-480E-24
AC/DC DIN Rail Power Supply (PSU), ITE, Industrial & Laboratory Equipment, 1 Output, 480 W, 24 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XDR-480E Series
- No. of Outputs: 1 Output
- Output Power Max: 480W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 82.49 € |
| Current stock | 10+ |
| Lead time | 30 days |
## 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** **User’s Manual** **==> picture [494 x 411] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g IS13252<br>www.ID 2000000000tuv.com THOMAS SAMUEL THOMAS SAMUEL<br>®<br>LISTED@ BS EN/EN62368-1 4 CBO IEC62368-1 AS/NES61558-1 gq KC62368-1 &<br>UL61010 BS EN/EN61558-1BS EN/EN61010 IEC61558-1IEC61010 AS/NES62368-1 (By request) (By request)<br>G S «) FAL C € om = | Automate Industrial Security Network Telecom<br>CNS15598-1 © GB4943.1 @ HCE TPTC004 XK CYCONC U GS<br>(Applying)<br>■ Features ■ Applications<br>* 85~264Vac input with PFC * Industrial control system<br>- Global certificates in multi-fields * Semiconductor fabrication<br>. 48mm slim width a * Electro-mechanical apparatus<br>•<br>, High efficiency up to 96 S and no load power dissipation<1 .2\V Battery charger<br>* Built-in constant current limiting circuit<br>- Current sharing up to 1920W (3+1) for parallel use<br>- Protections: Short circuit / Overload / Over voltage<br>/ Over temperature<br>- Fanless design, cooling by free air convection ■ GTIN CODE<br>https://www.meanwell.com/serviceGTIN.aspx<br>- Over voltage category Ⅲ (OVC Ⅲ ) MW Search:<br>- -40~+70°C wide range operation temperature (>+50 ℃ derating)<br>- Operating altitude up to 5000 meters<br>* Built-in DC OK relay contact<br>- Can be installed on DIN rail TS-35/7.5 or 15<br>> 3 years warranty<br>■ Description<br>The XDR-480E series is a 480W AC/DC economical ultra slim industrial DIN rail power. Key<br>this series include a narrow 48mm casing, optimizing system installation space, and an ultra-wide<br>range of 85~264Vac suitable for global use. It boasts a maximum efficiency of 96% and a low<br>power consumption <1.2W for energy savings and carbon reduction. It has built-in constant<br>fanless design, a wide operating temperature range of -40 to +70 ℃ (upto +50 ℃ _ at full load);<br>**----- End of picture text -----**<br> - _File Name:XDR-480E-SPEC 2025-03-25_ 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** ## **SPECIFICATION** |**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25<br>/ 70%RH<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>Class A<br>**Note.4**<br>UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>**OVER VOLTAGE CATEGORY**<br>IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000<br>**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**AC VOLTAGE RANGE**<br>**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1500ms, 150ms/230V<br>3000ms, 150ms/115V<br>at full load<br>ac<br>ac<br>15ms/230V<br>15ms/115V<br>at full load<br>ac<br>ac<br>85 ~ 264Vac<br>1W@115Vac & 230Vac<br>6A/115V<br>3A/230V<br>ac<br>ac<br>COLD START<br>/115V<br>/230V<br>ac<br>ac<br>15A<br>30A<br><1mA / 240Vac<br>Protection type : Shut down o/p voltage,recovers automatically after temperature goes down<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note )6**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**VOLTAGE TOLERANCE**<br>**Note.3**<br>**EMC IMMUNITY**<br>**FUNCTION**<br>Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>**PARALLEL (**<br>**)**<br>**Droop Mode**<br>Up to<br>units;Please refer to<br>1920W<br>(3+1)<br>Max<br>Function Manual for more details<br>**POWDR FACTOR (Typ.)**<br>PF>0.95/230V<br>PF>0.98/115V<br>at full load<br>ac<br>ac<br>**XDR-480E-12**<br>±2.0%<br>±0.5%<br>±1.0%<br>30A<br>0 ~ 30A<br>360W<br>100mVp-p<br>12 ~ 1 V<br>5<br>**XDR-480E-48**<br>±1.0%<br>±0.5%<br>±1.0%<br>10A<br>0 ~ 10A<br>480W<br>150mVp-p<br>48 ~ 55V<br>**XDR-480E-36**<br>±1.0%<br>±0.5%<br>±1.0%<br>13.3A<br>0 ~ 13.3A<br>478.8W<br>150mVp-p<br>36 ~ 42V<br>94%<br>9 %<br>6<br>95. %<br>5<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>**Test Level / Note**<br>Level 3,<br>air ; Level ,<br>contact; criteria A<br>2<br>8KV<br>4KV<br>Level 3, 10V/m ; criteria A<br>Level , 2KV ; criteria A<br>3<br>Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A<br>Level 3, 10V ; criteria A<br>Level 4, 30A/m ; criteria A<br>**48*125.2*1**<br>**mm (W*H*D)**<br>**25**<br>890<br>12<br>13<br>1 16<br>g;<br>pcs/<br>Kg/ .<br>CUFT<br>1482 0<br>258 3<br>. K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>. K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>**XDR-480E-24**<br>±1.0%<br>±0.5%<br>±1.0%<br>20A<br>0 ~ 20A<br>480W<br>120mVp-p<br>24 ~ 2 V<br>9<br>9 . %<br>5 5<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**DC VOLTAGE RANGE**<br>120 ~ 370Vdc<br>**FREQUENCY RANGE**<br>47 ~ 63Hz<br>12V<br>48V<br>36V<br>24V<br>Max<br>8<br>. 1 V<br>Max<br>3<br>. 6 V<br>Max. 50V<br>Max<br>5<br>. 3 V<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed.<br>**OVERLOAD**<br>Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed<br>within 30%~100% rated output voltage, recovers automatically after fault condition is removed<br>Constant current limiting without shutdown<br>105~130% rated output power<br>**DC OK**<br>**TACT**<br>**RELAY CON**<br>1.2W@115Vac & 230Vac<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,<br>re<br>~~asO~~<br>a<br>R**e**<br>~~G~~<br>~~sO~~<br>~~OO~~<br>~~GG~~<br>~~|~~<br>~~a~~<br>a<br>a<br>~~se~~<br>a<br>a<br>a<br>7~~Eee~~<br>a<br>es<br>Rs<br>a<br>a<br>fe<br>~~esee~~<br>ee<br>~~ee~~<br>a<br>a<br>Co<br>a<br>a<br>ae<br>a<br>a<br>**a**ea<br>aea<br>~~ReGG~~<br>RR<br>es<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25<br>/ 70%RH<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>Class A<br>**Note.4**<br>UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>**OVER VOLTAGE CATEGORY**<br>IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000<br>**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**AC VOLTAGE RANGE**<br>**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1500ms, 150ms/230V<br>3000ms, 150ms/115V<br>at full load<br>ac<br>ac<br>15ms/230V<br>15ms/115V<br>at full load<br>ac<br>ac<br>85 ~ 264Vac<br>1W@115Vac & 230Vac<br>6A/115V<br>3A/230V<br>ac<br>ac<br>COLD START<br>/115V<br>/230V<br>ac<br>ac<br>15A<br>30A<br><1mA / 240Vac<br>Protection type : Shut down o/p voltage,recovers automatically after temperature goes down<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note )6**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**VOLTAGE TOLERANCE**<br>**Note.3**<br>**EMC IMMUNITY**<br>**FUNCTION**<br>Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>**PARALLEL (**<br>**)**<br>**Droop Mode**<br>Up to<br>units;Please refer to<br>1920W<br>(3+1)<br>Max<br>Function Manual for more details<br>**POWDR FACTOR (Typ.)**<br>PF>0.95/230V<br>PF>0.98/115V<br>at full load<br>ac<br>ac<br>**XDR-480E-12**<br>±2.0%<br>±0.5%<br>±1.0%<br>30A<br>0 ~ 30A<br>360W<br>100mVp-p<br>12 ~ 1 V<br>5<br>**XDR-480E-48**<br>±1.0%<br>±0.5%<br>±1.0%<br>10A<br>0 ~ 10A<br>480W<br>150mVp-p<br>48 ~ 55V<br>**XDR-480E-36**<br>±1.0%<br>±0.5%<br>±1.0%<br>13.3A<br>0 ~ 13.3A<br>478.8W<br>150mVp-p<br>36 ~ 42V<br>94%<br>9 %<br>6<br>95. %<br>5<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>**Test Level / Note**<br>Level 3,<br>air ; Level ,<br>contact; criteria A<br>2<br>8KV<br>4KV<br>Level 3, 10V/m ; criteria A<br>Level , 2KV ; criteria A<br>3<br>Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A<br>Level 3, 10V ; criteria A<br>Level 4, 30A/m ; criteria A<br>**48*125.2*1**<br>**mm (W*H*D)**<br>**25**<br>890<br>12<br>13<br>1 16<br>g;<br>pcs/<br>Kg/ .<br>CUFT<br>1482 0<br>258 3<br>. K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>. K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>**XDR-480E-24**<br>±1.0%<br>±0.5%<br>±1.0%<br>20A<br>0 ~ 20A<br>480W<br>120mVp-p<br>24 ~ 2 V<br>9<br>9 . %<br>5 5<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**DC VOLTAGE RANGE**<br>120 ~ 370Vdc<br>**FREQUENCY RANGE**<br>47 ~ 63Hz<br>12V<br>48V<br>36V<br>24V<br>Max<br>8<br>. 1 V<br>Max<br>3<br>. 6 V<br>Max. 50V<br>Max<br>5<br>. 3 V<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed.<br>**OVERLOAD**<br>Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed<br>within 30%~100% rated output voltage, recovers automatically after fault condition is removed<br>Constant current limiting without shutdown<br>105~130% rated output power<br>**DC OK**<br>**TACT**<br>**RELAY CON**<br>1.2W@115Vac & 230Vac<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,<br>re<br>~~asO~~<br>a<br>R**e**<br>~~G~~<br>~~sO~~<br>~~OO~~<br>~~GG~~<br>~~|~~<br>~~a~~<br>a<br>a<br>~~se~~<br>a<br>a<br>a<br>7~~Eee~~<br>a<br>es<br>Rs<br>a<br>a<br>fe<br>~~esee~~<br>ee<br>~~ee~~<br>a<br>a<br>Co<br>a<br>a<br>ae<br>a<br>a<br>**a**ea<br>aea<br>~~ReGG~~<br>RR<br>es<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|**XDR-480E-12**<br>re<br>|**XDR-480E-12**<br>re<br>|**XDR-480E-24**<br>|**XDR-480E-24**<br>|**XDR-480E-36**<br>|**XDR-480E-36**<br>|**XDR-480E-48**<br>| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**<br>~~a~~|12V<br>re<br>||24V<br>||36V<br>||48V<br>| ||**RATED CURRENT**<br>~~a~~|30A<br>re<br>||20A<br>||13.3A<br>||10A<br>| ||**CURRENT RANGE**<br>~~asO~~|0 ~ 30A<br>re<br>~~sO~~||0 ~ 20A<br>~~sO~~||0 ~ 13.3A<br>~~sO~~||0 ~ 10A<br>~~sO~~| ||**RATED POWER**<br>a<br>R**e**|360W||480W||478.8W||480W| ||**RIPPLE & NOISE (max.)**<br>**Note.2**<br>a<br>R**e**|100mVp-p||120mVp-p<br>~~G~~||150mVp-p<br>~~G~~||150mVp-p<br>~~G~~| ||**VOLTAGE ADJ. RANGE**<br>R**e**|12 ~ 1 V<br>5||24 ~ 2 V<br>9<br>~~G~~||36 ~ 42V<br>~~G~~||48 ~ 55V<br>~~G~~| ||**VOLTAGE TOLERANCE**<br>**Note.3**<br>~~sO~~<br>~~OO~~|±2.0%<br>~~sO~~<br>~~OO~~||±1.0%<br>~~G~~<br>~~sO~~<br>~~OO~~||±1.0%<br>~~G~~<br>~~sO~~<br>~~OO~~||±1.0%<br>~~G~~<br>~~sO~~<br>~~OO~~| ||**LINE REGULATION**<br>~~OO~~|±0.5%<br>~~OO~~||±0.5%<br>~~OO~~||±0.5%<br>~~OO~~||±0.5%<br>~~OO~~| ||**LOAD REGULATION**<br>~~OO~~<br>~~GG~~<br>~~|~~|±1.0%<br>~~OO~~<br>~~GG~~<br>~~|~~||±1.0%<br>~~OO~~<br>~~GG~~<br>~~|~~||±1.0%<br>~~OO~~<br>~~GG~~<br>~~|~~||±1.0%<br>~~OO~~<br>~~GG~~<br>~~|~~| ||**SETUP, RISE TIME**<br>~~|~~|1500ms, 150ms/230V<br>3000ms, 150ms/115V<br>at full load<br>ac<br>ac<br>~~|~~||||||| ||**HOLD UP TIME (Typ.)**<br>~~a~~<br>a|15ms/230V<br>15ms/115V<br>at full load<br>ac<br>ac<br>~~a~~||||||| ||**AC VOLTAGE RANGE**<br>~~a~~<br>a|85 ~ 264Vac<br>~~a~~||||||| ||**DC VOLTAGE RANGE**<br>a|120 ~ 370Vdc||||||| ||**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>a|1W@115Vac & 230Vac||||1.2W@115Vac & 230Vac||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||||| ||**POWDR FACTOR (Typ.)**|PF>0.95/230V<br>PF>0.98/115V<br>at full load<br>ac<br>ac||||||| ||**EFFICIENCY (Typ.)**<br>~~se~~|94%<br>~~se~~||9 . %<br>5 5<br>~~se~~||95. %<br>5<br>~~se~~||9 %<br>6<br>~~se~~| ||**AC CURRENT (Typ.)**<br>a|6A/115V<br>3A/230V<br>ac<br>ac||||||| ||**INRUSH CURRENT (Typ.)**<br>a<br>a<br>a|COLD START<br>/115V<br>/230V<br>ac<br>ac<br>15A<br>30A||||||| ||**LEAKAGE CURRENT**<br>a<br>a|<1mA / 240Vac||||||| ||**OVERLOAD**<br>a<br>|Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed<br>within 30%~100% rated output voltage, recovers automatically after fault condition is removed<br>Constant current limiting without shutdown<br>105~130% rated output power<br>||||||| ||**OVER VOLTAGE**<br>|Max<br>8<br>. 1 V<br>Max<br>3<br>. 6 V<br>Max. 50V<br>Max<br>5<br>. 3 V<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed.<br>||||||| ||**OVER TEMPERATURE**<br>|Protection type : Shut down o/p voltage,recovers automatically after temperature goes down<br>||||||| ||**PARALLEL (**<br>**)**<br>**Droop Mode**<br>~~Eee~~|Up to<br>units;Please refer to<br>1920W<br>(3+1)<br>Max<br>Function Manual for more details<br>~~Eee~~||||||| ||**DC OK**<br>**TACT**<br>**RELAY CON**<br>~~Eee~~|Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>~~Eee~~||||||| ||**WORKING TEMP.**<br>~~Eee~~<br>a<br>es|-40 ~ +70℃(Refer to "Derating Curve")<br>~~Eee~~||||||| ||**WORKING HUMIDITY**<br>a<br>es<br>Rs|20 ~ 95% RH non-condensing||||||| ||**STORAGE TEMP., HUMIDITY**<br>es<br>Rs|-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃||||||| ||**TEMP. COEFFICIENT**<br>Rs<br>a<br>a|±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)||||||| ||**VIBRATION**<br>a<br>a|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||||| ||**SAFETY STANDARDS**<br>a|UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,||||||| ||**Note.4**<br>**OVER VOLTAGE CATEGORY**|IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000||||||| ||**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**|IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1||||||| ||**WITHSTAND VOLTAGE**<br>fe<br>~~es~~|I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>fe<br>~~ee~~||||||| ||**ISOLATION RESISTANCE**<br>fe<br>~~es~~|I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25<br>/ 70%RH<br>℃<br>fe<br>~~ee~~||||||| ||**EMC EMISSION**<br>**EMC IMMUNITY**<br>~~es~~<br>Co<br>RR|**Parameter**<br>~~ee~~<br>ee|**Standard**||||**Test Level / Note**|| |||Conducted<br>~~ee~~<br>ee<br>~~ee~~|BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>~~ee~~||||Class B<br>~~ee~~|| |||Radiated<br>ee<br>~~ee~~<br>a|BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>~~ee~~||||Class B<br>~~ee~~|| |||Harmonic Current<br>a|BS EN/EN61000-3-2||||Class A|| |||Voltage Flicker<br>a<br>Co|BS EN/EN61000-3-3<br>Co||||-----|| |||BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>Co||||||| |||**Parameter**<br>Co<br>a<br>ae|**Standard**<br>Co<br>a||**Test Level / Note**|||| |||ESD<br>ae|BS EN/EN61000-4-2||Level 3,<br>air ; Level ,<br>contact; criteria A<br>2<br>8KV<br>4KV|||| |||Radiated<br>ae<br>a<br>**a**e|BS EN/EN61000-4-3<br>a<br>a||Level 3, 10V/m ; criteria A|||| |||EFT / Burst<br>**a**e|BS EN/EN61000-4-4<br>a||Level , 2KV ; criteria A<br>3|||| |||Surge<br>**a**e<br>ae|BS EN/EN61000-4-5<br>a<br>a||Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A|||| |||Conducted<br>ae<br>~~Re~~|BS EN/EN61000-4-6<br>a<br>~~GG~~||Level 3, 10V ; criteria A<br>~~GG~~|||| |||Magnetic Field<br>ae<br>~~Re~~|BS EN/EN61000-4-8<br>a<br>~~GG~~||Level 4, 30A/m ; criteria A<br>~~GG~~|||| ||**MTBF**<br>RR<br>es|1482 0<br>258 3<br>. K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>. K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>~~ReGG~~||||||| ||**DIMENSION**<br>RR<br>es|**48*125.2*1**<br>**mm (W*H*D)**<br>**25**<br>~~ReGG~~||||||| ||**PACKING**<br>es|890<br>12<br>13<br>1 16<br>g;<br>pcs/<br>Kg/ .<br>CUFT||||||| ||℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|||||||| EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:XDR-480E-SPEC 2025-03-25_ 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** ## **Block Diagram** **==> picture [470 x 609] intentionally omitted <==** **----- Start of picture text -----**<br> PFCfosc: 65KHz<br>PWM fosc : 70KHz<br>RELAY<br>DC OK<br>CONTROL<br>I/P FILTEREMI RECTIFIERS& PFC SWITCHINGPOWER RECTIFIERS& +Vo-Vo<br>FILTER<br>PFC O.L.P. O.C.P.<br>CONTROL<br>FG PWM O.V.P.<br>O.T.P. CONTROL<br>DETECTION<br>CIRCUIT<br>CURRENT<br>SHARE PLINK<br>Derating Curve<br>100<br>85<br>80<br>75<br>50<br>-40 -30 0 10 20 30 40 50 60 70 (VERTICAL)<br>AMBIENTTEMPERATURE( ℃ )<br>Static Characteristics<br>100<br>90<br>85<br>80<br>70<br>60<br>50<br>40<br>85 100 115 120 180 200 220 230 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:XDR-480E-SPEC 2025-03-25_ 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** ~~_~~ ## **Function Manual** **==> picture [491 x 287] intentionally omitted <==** **----- Start of picture text -----**<br> Pin No. Function Description<br>Contact Close: PSU turns ON/DC_OK<br>1,2 DC OK Relay Contact<br>Contact Open: PSU turns OFF/DC_fail<br>3,4 Paraller Use Link(PLINK) PLINK should be short to enable droop parallel use.(Default disable)<br>1.DC OK Relay Contact<br>Contact Close PSU turns ON / DC OK.<br>Contact Open PSU turns OFF / DC Fail.<br>Contact Ratings (max.) 30Vdc/1A, 30Vac/0.5A resistive load.<br>BN 1<br>R<br>\ | | U D> External voltage source (U) and resistor (R)<br>(The max. Sink is 30Vdc/1A ,30Vac 0 5A/ . )<br>reiE 2 fo<br>Internal circuit of DC_OK, via relay contact<br>Parallel Use<br>XDR-480E has the built-in droop mode current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below :<br>(1) Difference of output voltages among parallel units should be less than 0.1V.<br>**----- End of picture text -----**<br> ## **1.DC OK Relay Contact** ## **2.Parallel Use** (2) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9. (3) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. (4) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - (5) When in parallel operation, the minimum output load should be greater than 7% of total output load. (Min. load >7% rated current per unit x number of unit) - (6) In parallel connection, maybe only one unit (master) operate if the total output load is less than 7% of rated load condition. The other PSUs (slaves) may go into standby mode and their output LEDs & relays will not turn on. (7) PLINK lines should be shorted locally. (8) In parallel operation,after overload or short circuit fault occurs, re-power on to recover. - (9) The “Parallel Use” mode regulates the output voltage in such a manner that the rated load is approx. 4% lower than the no-load voltage (12V:approx.7%). **==> picture [451 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> For example XDR-480E-24:<br>No load output voltage=24V<br>Normal load output current=0~100% load output voltage=24V~23V20A +Vo24V+Vo = Vo20A Vo e Status i DC OK '<br>24-29Vdc Adj.Vo<br>DC OK<br>Parallel Use PLINK<br>25 Bs ot 2<br>XDR-480E-24<br>24 Typ.<br>23 je |<br>22<br>100-240Vac<br>0 10 20 L N<br>Output Current (A)<br>= Enable I :PLINK should be short<br>)V<br>Output Voltage (<br>**----- End of picture text -----**<br> _File Name:XDR-480E-SPEC 2025-03-25_ 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** **==> picture [403 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> + -<br>LOAD<br>+Vo<br>-Vo<br>1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4<br>+Vo +Vo Vo Vo +Vo +Vo Vo Vo +Vo +Vo Vo Vo +Vo +Vo Vo Vo<br>Status Status Status Status<br>Adj.Vo Adj.Vo Adj.Vo Adj.Vo<br>DC OK 12 DC OK 12 DC OK 12 DC OK 12<br>Parallel Use 43 Parallel Use 43 Parallel Use 43 Parallel Use 43<br>XDR-480E XDR-480E XDR-480E XDR-480E<br>PSU1 PSU2 PSU3 PSU4<br>100-240Vac 100-240Vac 100-240Vac 100-240Vac<br>L N L N L N L N<br>1 2 3 1 2 3 1 2 3 1 2 3<br>**----- End of picture text -----**<br> ※ Please contact MEAN WELL for more details. _File Name:XDR-480E-SPEC 2025-03-25_ 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** **==> picture [512 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>(Unit:mm , Tolerance ±1mm) Case No.303<br>A : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1,2 DC Output +Vo<br>3,4 DC Output -Vo<br>B : Control Pin No.Assignment<br>Pin No. Assignment<br>1,2 DC OK Relay Contact<br>3 4, Parallel Use Link(Current Sharing)<br>48<br>125<br>1 2 3 4<br>A<br>+Vo +Vo Vo Vo<br>Status<br>Adj.Vo<br>Parallel UseDC OK 1243 B<br>100-240Vac<br>L N<br>C<br>1 2 3<br>C : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 AC/L or DC Input +Vin<br>2 AC/N or DC Input -Vin<br>3 FG<br>Recommend Wiring<br>AC Input T.B DC Output T.B Signal connector<br>Solid Wire 6mm2 max. 6mm2 max. 1.5mm2 max.<br>XDR-480E-12 12~10 AWG<br>A.W.G 18~10 AWG 24~16 AWG<br>XDR-480E-24/36/48 16~10 AWG<br>Wire Stripping Length 10~11mm 10~11mm 8~9mm<br>Screw Terminal Torque 5 Lb-In 5 Lb-In /<br>125.2<br>**----- End of picture text -----**<br> _File Name:XDR-480E-SPEC 2025-03-25_ 480W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-480E series** ## **Installation Instruction** This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) ## **InstallationManual** Pleasereferto:http://www.meanwell.com/manual.html _File Name:XDR-480E-SPEC 2025-03-25_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →