Image not available
Illustrative purposes only
XDR-120E-36
AC/DC DIN Rail Power Supply (PSU), ITE, Industrial & Laboratory Equipment, 1 Output, 119.88 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XDR-120E Series
- No. of Outputs: 1 Output
- Output Power Max: 119.88W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.33A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 36V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 17.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
120W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-120E series** **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [494 x 409] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g IS13252<br>www.ID 2000000000tuv.com THOMAS SAMUEL THOMAS SAMUEL<br>©LISTED BS EN/EN62368-1 2 CBB IEC62368-1 AS/NES61558-1 g KC62368-1 kK<br>UL61010 BS EN/EN61558-1BS EN/EN61010 IEC61558-1IEC61010 AS/NES62368-1 (By request) (By request)<br>eS @HICE us& fa<br>CNS15598-1 GB4943.1 TPTC004<br>(Applying)<br>■ Features ■ Applications<br>* 85~264Vac input range * Industrial control system<br>- Global certificates in multi-fields * Semiconductor fabrication<br>(ITE 62368-1, Industrial 61558-1/-2-16,6101 0) 7 Factory automation<br>* 30mm slim width - Electro-mechanical apparatus<br>•<br>- High efficiency up to 91% and no load power dissipation<1W Battery charger<br>* Built-in constant current limiting circuit<br>- Protections: Short circuit / Overload / Over voltage<br>/ Over temperature<br>- Fanless design, cooling by free air convection<br>■<br>‘Over voltage category Ⅲ (OVC Ⅲ ) GTIN CODE<br>- -40~+70°C wide. range operation; temperature (>+50 ℃ derating); MW Search: https://www.meanwell.com/serviceGTIN.aspx<br>- Operating altitude up to 5000 meters<br>* Built-in DC OK relay contact<br>- Can be installed on DIN rail TS-35/7.5 or 15<br>> 3 years warranty<br>■ Description<br>The XDR-120E series is a 120W AC/DC economical ultra slim industrial DIN rail power. Key<br>this series include a narrow 30mm casing, optimizing system installation space, and an ultra-wide<br>range of 85~264Vac suitable for global use. It boasts a maximum efficiency of 91% and a low<br>power consumption <1W for energy savings and carbon reduction. It has built-in constant<br>℃ ℃<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:XDR-120E-SPEC 2025-03-11_ 120W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-120E series** ## **SPECIFICATION** |**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-2<br>Class A<br>**Note.5**<br>UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>**OVER VOLTAGE CATEGORY**<br>IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000<br>IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**AC VOLTAGE RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**Note.4**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1 00ms, 0ms/230V<br>00ms,<br>ms/115V<br>at full load<br>2<br>6<br>ac<br>25<br>60<br>ac<br>16<br>ac 8<br>ac<br>ms/230V<br>ms/115V<br>at full load<br>85 ~ 264Vac<br>0.9W@115Vac & 230Vac<br>2 3<br>ac 1<br>ac<br>. A/115V<br>3A/230V<br>.<br>COLD START<br>/115V<br>/230V<br>ac<br>ac<br>20<br>4<br>A<br>0A<br><1mA / 240Vac<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Protection type :<br>o/p voltage,recovers automatically after fault condition is removed<br>Shut down<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note )7**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**VOLTAGE TOLERANCE**<br>**Note.3**<br>**EMC IMMUNITY**<br>**FUNCTION**<br>Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>±2.0%<br>±0.5%<br>±1.0%<br>10A<br>0 ~ 0A<br>1<br>120W<br>100mVp-p<br>12 ~ 1 V<br>5<br>±1.0%<br>±0.5%<br>±1.0%<br>2.5A<br>0 ~<br>A<br>2.5<br>1 0mVp-p<br>5<br>48 ~ 55V<br>±1.0%<br>±0.5%<br>±1.0%<br>3 33<br>.<br>A<br>0 ~<br>A<br>3.33<br>1 0mVp-p<br>5<br>36 ~ 42V<br>89%<br>1 ~ 1 V<br>5<br>8<br>9 %<br>1<br>56 ~ 65V<br>9 %<br>1<br>43 ~ 50V<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>**Test Level / Note**<br>Level 3,<br>air ; Level 3,<br>contact; criteria A<br>8KV<br>4KV<br>Level 3, 10V/m ; criteria A<br>Level 2, 2KV ; criteria A<br>Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A<br>Level 3, 10V ; criteria A<br>Level 4, 30A/m ; criteria A<br>**30*125.2*116mm (W*H*D)**<br>420<br>24<br>11 1<br>1 27<br>g;<br>pcs/<br>. Kg/ .<br>CUFT<br>2223 1<br>440 4<br>. K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>. K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>±1.0%<br>±0.5%<br>±1.0%<br>5A<br>0 ~ A<br>5<br>1 0mVp-p<br>2<br>24 ~ 2 V<br>9<br>9 %<br>1<br>30<br>4<br>~ 3 V<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**DC VOLTAGE RANGE**<br>120 ~ 370Vdc<br>**FREQUENCY RANGE**<br>47 ~ 63Hz<br>105-130% rated output power, constant current limiting without shutdown,recovers automatically after fault condition is removed<br>12V<br>48V<br>36V<br>24V<br>**XDR-**<br>**0E-12**<br>**12**<br>**XDR-**<br>**0E-48**<br>**12**<br>**XDR-**<br>**0E-36**<br>**12**<br>**XDR-**<br>**0E-24**<br>**12**<br>**MODEL**<br>120W<br>119.88W<br>120W<br>**DC OK**<br>**TACT**<br>**RELAY CON**<br>1W@115Vac & 230Vac<br>**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,<br>a<br>a ~~GO~~<br>~~se~~<br>a~~eG~~<br>~~CG~~<br>~~sO~~<br>ee<br>~~GC~~<br>rs<br>a<br>Ce~~eG~~<br>~~eG~~<br>cn<br>GO<br>a~~se~~<br>a<br>a<br>a<br>~~Ce~~<br>Rs~~sD~~<br>~~Se~~<br>ee<br>es<br>Cea<br>es<br>~~rsee~~<br>re<br>ee<br>ee<br>a<br>~~Ce~~<br>~~a~~<br>~~a~~<br>~~a~~ee<br>~~a~~<br>~~a~~<br>~~ae~~ a<br>a<br>a<br>ae<br>~~as~~<br>a<br>es<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. When the temperature is between -40 ° C and -20 ° C and the input voltage is between 85V and 90V, the temperature derating curve drops to40%<br>.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>6. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-2<br>Class A<br>**Note.5**<br>UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>**OVER VOLTAGE CATEGORY**<br>IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000<br>IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**AC VOLTAGE RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**Note.4**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1 00ms, 0ms/230V<br>00ms,<br>ms/115V<br>at full load<br>2<br>6<br>ac<br>25<br>60<br>ac<br>16<br>ac 8<br>ac<br>ms/230V<br>ms/115V<br>at full load<br>85 ~ 264Vac<br>0.9W@115Vac & 230Vac<br>2 3<br>ac 1<br>ac<br>. A/115V<br>3A/230V<br>.<br>COLD START<br>/115V<br>/230V<br>ac<br>ac<br>20<br>4<br>A<br>0A<br><1mA / 240Vac<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Protection type :<br>o/p voltage,recovers automatically after fault condition is removed<br>Shut down<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note )7**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**VOLTAGE TOLERANCE**<br>**Note.3**<br>**EMC IMMUNITY**<br>**FUNCTION**<br>Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>±2.0%<br>±0.5%<br>±1.0%<br>10A<br>0 ~ 0A<br>1<br>120W<br>100mVp-p<br>12 ~ 1 V<br>5<br>±1.0%<br>±0.5%<br>±1.0%<br>2.5A<br>0 ~<br>A<br>2.5<br>1 0mVp-p<br>5<br>48 ~ 55V<br>±1.0%<br>±0.5%<br>±1.0%<br>3 33<br>.<br>A<br>0 ~<br>A<br>3.33<br>1 0mVp-p<br>5<br>36 ~ 42V<br>89%<br>1 ~ 1 V<br>5<br>8<br>9 %<br>1<br>56 ~ 65V<br>9 %<br>1<br>43 ~ 50V<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>**Test Level / Note**<br>Level 3,<br>air ; Level 3,<br>contact; criteria A<br>8KV<br>4KV<br>Level 3, 10V/m ; criteria A<br>Level 2, 2KV ; criteria A<br>Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A<br>Level 3, 10V ; criteria A<br>Level 4, 30A/m ; criteria A<br>**30*125.2*116mm (W*H*D)**<br>420<br>24<br>11 1<br>1 27<br>g;<br>pcs/<br>. Kg/ .<br>CUFT<br>2223 1<br>440 4<br>. K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>. K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>±1.0%<br>±0.5%<br>±1.0%<br>5A<br>0 ~ A<br>5<br>1 0mVp-p<br>2<br>24 ~ 2 V<br>9<br>9 %<br>1<br>30<br>4<br>~ 3 V<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**DC VOLTAGE RANGE**<br>120 ~ 370Vdc<br>**FREQUENCY RANGE**<br>47 ~ 63Hz<br>105-130% rated output power, constant current limiting without shutdown,recovers automatically after fault condition is removed<br>12V<br>48V<br>36V<br>24V<br>**XDR-**<br>**0E-12**<br>**12**<br>**XDR-**<br>**0E-48**<br>**12**<br>**XDR-**<br>**0E-36**<br>**12**<br>**XDR-**<br>**0E-24**<br>**12**<br>**MODEL**<br>120W<br>119.88W<br>120W<br>**DC OK**<br>**TACT**<br>**RELAY CON**<br>1W@115Vac & 230Vac<br>**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,<br>a<br>a ~~GO~~<br>~~se~~<br>a~~eG~~<br>~~CG~~<br>~~sO~~<br>ee<br>~~GC~~<br>rs<br>a<br>Ce~~eG~~<br>~~eG~~<br>cn<br>GO<br>a~~se~~<br>a<br>a<br>a<br>~~Ce~~<br>Rs~~sD~~<br>~~Se~~<br>ee<br>es<br>Cea<br>es<br>~~rsee~~<br>re<br>ee<br>ee<br>a<br>~~Ce~~<br>~~a~~<br>~~a~~<br>~~a~~ee<br>~~a~~<br>~~a~~<br>~~ae~~ a<br>a<br>a<br>ae<br>~~as~~<br>a<br>es<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. When the temperature is between -40 ° C and -20 ° C and the input voltage is between 85V and 90V, the temperature derating curve drops to40%<br>.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>6. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|**XDR-**<br>**0E-12**<br>**12**|**XDR-**<br>**0E-12**<br>**12**|**XDR-**<br>**0E-24**<br>**12**|**XDR-**<br>**0E-24**<br>**12**|**XDR-**<br>**0E-36**<br>**12**|**XDR-**<br>**0E-36**<br>**12**|**XDR-**<br>**0E-48**<br>**12**| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**<br>a|12V<br>a<br>~~GO~~||24V<br>~~GO~~||36V<br>~~GO~~||48V<br>~~GO~~| ||**RATED CURRENT**<br>a|10A<br>~~GO~~||5A<br>~~GO~~||3 33<br>.<br>A<br>~~GO~~||2.5A<br>~~GO~~| ||**CURRENT RANGE**<br>a <br>~~se~~|0 ~ 0A<br>1<br> ~~GO~~<br>~~se~~||0 ~ A<br>5<br>~~GO~~<br>~~se~~||0 ~<br>A<br>3.33<br>~~GO~~<br>~~se~~||0 ~<br>A<br>2.5<br>~~GO~~<br>~~se~~| ||**RATED POWER**<br>a|120W<br>||120W<br>||119.88W<br>||120W<br>| ||**RIPPLE & NOISE (max.)**<br>**Note.2**<br>a~~eG~~<br>~~CG~~|100mVp-p<br>~~eG~~<br>~~CG~~||1 0mVp-p<br>2<br>~~eG~~<br>~~CG~~||1 0mVp-p<br>5<br>~~eG~~<br>~~CG~~||1 0mVp-p<br>5<br>~~eG~~<br>~~CG~~| ||**VOLTAGE ADJ. RANGE**<br>~~CG~~|12 ~ 1 V<br>5<br>~~CG~~||24 ~ 2 V<br>9<br>~~CG~~||36 ~ 42V<br>~~CG~~||48 ~ 55V<br>~~CG~~| ||**VOLTAGE TOLERANCE**<br>**Note.3**<br>~~CG~~<br>~~sO~~<br>ee|±2.0%<br>~~CG~~<br>~~sO~~<br>ee||±1.0%<br>~~CG~~<br>~~sO~~<br>~~GC~~||±1.0%<br>~~CG~~<br>~~sO~~<br>~~GC~~||±1.0%<br>~~CG~~<br>~~sO~~<br>~~GC~~| ||**LINE REGULATION**<br>ee<br>rs|±0.5%<br>ee||±0.5%<br>~~GC~~||±0.5%<br>~~GC~~||±0.5%<br>~~GC~~| ||**LOAD REGULATION**<br>ee<br>rs<br>a|±1.0%<br>ee||±1.0%<br>~~GC~~||±1.0%<br>~~GC~~||±1.0%<br>~~GC~~| ||**SETUP, RISE TIME**<br>rs<br>a<br>Ce|1 00ms, 0ms/230V<br>00ms,<br>ms/115V<br>at full load<br>2<br>6<br>ac<br>25<br>60<br>ac<br>||||||| ||**HOLD UP TIME (Typ.)**<br>Ce|16<br>ac 8<br>ac<br>ms/230V<br>ms/115V<br>at full load<br>||||||| ||**AC VOLTAGE RANGE**<br>Ce~~eG~~|85 ~ 264Vac<br>~~eG~~||||||| ||**DC VOLTAGE RANGE**<br>~~eG~~|120 ~ 370Vdc<br>~~eG~~||||||| ||**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>~~eG~~|0.9W@115Vac & 230Vac<br>~~eG~~||1W@115Vac & 230Vac<br>~~eG~~||||| ||**FREQUENCY RANGE**<br>~~eG~~<br>cn|47 ~ 63Hz<br>~~eG~~<br>cn<br>GO||||||| ||**EFFICIENCY (Typ.)**<br>cn|89%<br>cn||9 %<br>1<br>GO||9 %<br>1<br>GO||9 %<br>1| ||**AC CURRENT (Typ.)**<br>cn<br>a~~se~~|2 3<br>ac 1<br>ac<br>. A/115V<br>3A/230V<br>.<br>cn<br>GO<br>~~se~~||||||| ||**INRUSH CURRENT (Typ.)**<br>~~se~~|COLD START<br>/115V<br>/230V<br>ac<br>ac<br>20<br>4<br>A<br>0A<br>~~se~~||||||| ||**LEAKAGE CURRENT**<br>a|<1mA / 240Vac||||||| ||**OVERLOAD**<br>a|105-130% rated output power, constant current limiting without shutdown,recovers automatically after fault condition is removed||||||| ||**OVER VOLTAGE**|Protection type : Shut down o/p voltage, re-power on to recover<br>1 ~ 1 V<br>5<br>8<br>56 ~ 65V<br>43 ~ 50V<br>30<br>4<br>~ 3 V<br>a<br>~~Ce~~||||||| ||**OVER TEMPERATURE**<br>~~sD~~|Protection type :<br>o/p voltage,recovers automatically after fault condition is removed<br>Shut down<br>~~sD~~||||||| ||**DC OK**<br>**TACT**<br>**RELAY CON**<br>~~sD~~|Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>~~sD~~||||||| ||**WORKING TEMP.**<br>**Note.4**<br>~~sD~~<br>~~Se~~<br>ee|-40 ~ +70℃(Refer to "Derating Curve")<br>~~sD~~<br>~~Se~~||||||| ||**WORKING HUMIDITY**<br>~~Se~~<br>ee<br>es|20 ~ 95% RH non-condensing<br>~~Se~~||||||| ||**STORAGE TEMP., HUMIDITY**<br>ee<br>es<br>Ce|-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃||||||| ||**TEMP. COEFFICIENT**<br>es<br>Cea|±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)||||||| ||**VIBRATION**<br>Cea|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||||| ||**SAFETY STANDARDS**<br>a|UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,||||||| ||**Note.5**<br>**OVER VOLTAGE CATEGORY**|IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000||||||| ||**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>es|IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1||||||| ||**WITHSTAND VOLTAGE**<br>es<br>~~rs~~|I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>~~ee~~||||||| ||**ISOLATION RESISTANCE**<br>es<br>~~rs~~|I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>~~ee~~||||||| ||**EMC EMISSION**<br>**EMC IMMUNITY**<br>~~rs~~<br>a|**Parameter**<br>~~ee~~<br>re|**Standard**<br>~~ee~~||||**Test Level / Note**<br>~~ee~~|| |||Conducted<br>re<br>ee|BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936||||Class B|| |||Radiated<br>re<br>ee<br>ee|BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936||||Class B|| |||Harmonic Current<br>ee<br>ee<br>a|BS EN/EN61000-3-2||||Class A|| |||Voltage Flicker<br>ee<br>a|BS EN/EN61000-3-2||||-----|| |||BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>a<br>~~Ce~~||||||| |||**Parameter**<br>~~Ce~~<br>~~a~~<br><br>~~a~~|**Standard**<br>~~Ce~~<br>~~a~~<br>~~a~~<br>ee||**Test Level / Note**<br>~~Ce~~<br>~~a~~|||| |||ESD<br>~~a~~<br>~~a~~|BS EN/EN61000-4-2<br>~~a~~ee||Level 3,<br>air ; Level 3,<br>contact; criteria A<br>8KV<br>4KV|||| |||Radiated<br>~~a~~<br>~~a~~<br>~~ae~~|BS EN/EN61000-4-3<br>~~a~~ee<br>~~a~~<br>||Level 3, 10V/m ; criteria A|||| |||EFT / Burst<br>~~ae~~|BS EN/EN61000-4-4<br>~~a~~<br>a||Level 2, 2KV ; criteria A|||| |||Surge<br>~~ae~~ <br>a<br>ae|BS EN/EN61000-4-5<br>~~a~~<br> a<br>a||Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A|||| |||Conducted<br>ae<br>~~as~~|BS EN/EN61000-4-6||Level 3, 10V ; criteria A|||| |||Magnetic Field<br>ae<br>~~as~~|BS EN/EN61000-4-8||Level 4, 30A/m ; criteria A|||| ||**MTBF**<br>a<br>es|2223 1<br>440 4<br>. K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>. K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>~~as~~||||||| ||**DIMENSION**<br>es|**30*125.2*116mm (W*H*D)**||||||| ||**PACKING**<br>es|420<br>24<br>11 1<br>1 27<br>g;<br>pcs/<br>. Kg/ .<br>CUFT||||||| ||℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. When the temperature is between -40 ° C and -20 ° C and the input voltage is between 85V and 90V, the temperature derating curve drops to40%<br>.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>6. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|||||||| _File Name:XDR-120E-SPEC 2025-03-11_ 120W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-120E series** ## **Block Diagram** **==> picture [442 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> PWM fosc : 70KHz<br>RELAY<br>DC OK<br>CONTROL<br>EMI FILTER POWER RECTIFIERS +Vo<br>I/P & SWITCHING & -Vo<br>RECTIFIERS FILTER<br>C.C.<br>O.L.P.<br>FG PWM O.V.P.<br>O.T.P. CONTROL<br>DETECTION<br>CIRCUIT<br>**----- End of picture text -----**<br> ## **Derating Curve** **==> picture [240 x 363] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>75<br>50<br>-40 -30 0 10 20 30 40 50 60 70 (VERTICAL)<br>AMBIENTTEMPERATURE( ℃ )<br>Static Characteristics<br>100<br>90<br>80<br>75<br>70<br>60<br>50<br>40<br>85 100 115 120 180 200 220 230 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:XDR-120E-SPEC 2025-03-11_ 120W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-120E series** ## **Function Manual** **==> picture [286 x 537] intentionally omitted <==** **----- Start of picture text -----**<br> 1.DC OK Relay Contact<br>Contact Close PSU turns ON / DC OK.<br>Contact Open PSU turns OFF / DC Fail.<br>Contact Ratings (max.) 30Vdc/1A, 30Vac/0.5A resistive load.<br>ee 1 ———<br>R<br>blood U External voltage source (U) and resistor (R)<br>8 | | (The max. Sink is 30Vdc/1A ,30Vac 0 5A/ . )<br>ee 2 Le<br>Internal circuit of DC_OK, via relay contact<br>+Vo -Vo -Vo<br>24V 5A<br>@ Status<br>Vo<br>Adj.<br>24-29Vdc<br>DC OK<br>DC OK<br>XDR-120E-24<br>ime<br>100-240Vac<br>L N<br>**----- End of picture text -----**<br> _File Name:XDR-120E-SPEC 2025-03-11_ 120W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-120E series** **==> picture [451 x 609] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>(Unit:mm , Tolerance ±1mm) Case No.301<br>A : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 DC Output +Vo<br>2 3, DC Output -Vo<br>B : Control Pin No.Assignment<br>Pin No. Assignment<br>1,2 DC OK Relay Contact<br>30<br>116<br>1 2 3<br>A<br>+ Vo - Vo - Vo<br>Status<br>Vo<br>Adj.<br>12 B<br>DC OK<br>100-240Vac<br>L N<br>C<br>1 2 3<br>C : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 AC/L or DC Input +Vin<br>2 AC/N or DC Input -Vin<br>3 FG<br>Recommend Wiring<br>AC Input T.B DC Output T.B Signal connector<br>Solid Wire 6mm2 max. 6mm2 max. 1.5mm2 max.<br>A.W.G 22~10 AWG 22~10 AWG 24~16 AWG<br>Screw Terminal Torque 9 Lb-In 9 Lb-In /<br>125.2<br>**----- End of picture text -----**<br> _File Name:XDR-120E-SPEC 2025-03-11_ 120W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-120E series** ## **Installation Instruction** **==> picture [463 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>35<br>**----- End of picture text -----**<br> ## **InstallationManual** Pleasereferto:http://www.meanwell.com/manual.html _File Name:XDR-120E-SPEC 2025-03-11_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →