Image not available
Illustrative purposes only
UHP-500R-55
AC/DC Enclosed Power Supply (PSU), 127 to 370VDC, ITE, 1 Outputs, 500 W, 55 VDC, 8.9 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: UHP-500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 500W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 8.9A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 55VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 82.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
## 500W Slim Type with PFC Switching Supply **==> picture [240 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>S@S © GB4943 Wi; UL62368 1- 4 EN62368-1 www.ID 2000000000tuv.com ffl IEC62368-1 CB CE<br>■<br>**----- End of picture text -----**<br> - 20 ~+ 70 ℃ ## ■ ## **UHP - 500 series** Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus LED display application Power Source Equipment for PoE(55V model) ■ > ℃ ~70 ℃ **==> picture [75 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> ■ Model<br>UHP- 500<br>| Type<br>|__| R<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2020-08-24_ 500W Slim Type with PFC Switching Supply ## **UHP - 500 series** |3.6~4.4V<br>**VOLTAGE ADJ. RANGE Note.7**<br>110~140% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 30A/115VAC 60A/230VAC<br><0.75mA / 240VAC<br>4.62 ~ 5.46V<br>-30 ~ +70<br>(Refer to “Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>168K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PF<br>0.95/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥<br>12ms/230VAC 12ms/115VAC<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>4.2V<br>**UHP-500 -4.2**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>℃<br>The<br>The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives.<br>**ENVIRONMENT**<br>**PROTECTION**<br>232*81*31mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>4.85A/115VAC 2.6A/230VAC<br>**RATED POWER**<br>0.905kg; 16pcs/15.48kg/0.82CUFT<br>47 ~ 63Hz<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>4.5~5.5V<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>5V<br>11.4~12.6V<br>±0.5%<br>±0.3%<br>±1.0%<br>200mVp-p<br>12V<br>14.3~15.8V<br>200mVp-p<br>15V<br>22.8~25.2V<br>240mVp-p<br>24V<br>34.2~37.8V<br>360mVp-p<br>36V<br>45.6~50.4V<br>360mVp-p<br>48V<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>**UHP-500 -5**<br>**UHP-500 -12**<br>**UHP-500 -15 UHP-500 -24**<br>**UHP-500 -36**<br>**UHP-500 -48**<br>**FUNCTION**<br>**REDUNDANT(Optional)**<br>Contact rating(max.):30Vdc/1A resistive load<br>For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system<br>**DC OK SIGNAL(Optional)**<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to EN55032,GB/T9254,Class B, EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020<br>UL 62368-1,TUV EN62368-1,EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1, EAC TP TC 004 approved;Design refer to EN61558-2-16<br>80A<br>336W<br>80A<br>400W<br>41.7A<br>500.4W<br>33.4A<br>501W<br>20.9A<br>501.6W<br>13.9A<br>500.4W<br>501.6W<br>10.45A<br>**UHP-500 -55**<br>45~58V<br>500mVp-p<br>55V<br>±0.5%<br>±0.3%<br>±1.0%<br>500W<br>8.9A<br>89%<br>95%<br>94%<br>94%<br>94.5%<br>95%<br>90%<br>95%<br>60 ~ 69V<br>**INRUSH CURRENT (Typ.)Note9**<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance ‘includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5.<br>ambient temperature derating of 3.5<br>/1000m is needed for operating altitude greater than 2000m(6500ft)<br>6.<br>For guidance on how to perform these EMC tests,<br>please refer to “EMI testing of component power supplies.” (as available on http:/www.meanwell.com)<br>7. Please refer to derating currve.<br>8. R type efficiency slightly less than the Blank type, according to the actual measurement.<br>9.Inrush current parameter has 10% tolerance.|3.6~4.4V<br>**VOLTAGE ADJ. RANGE Note.7**<br>110~140% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 30A/115VAC 60A/230VAC<br><0.75mA / 240VAC<br>4.62 ~ 5.46V<br>-30 ~ +70<br>(Refer to “Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>168K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PF<br>0.95/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥<br>12ms/230VAC 12ms/115VAC<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>4.2V<br>**UHP-500 -4.2**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>℃<br>The<br>The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives.<br>**ENVIRONMENT**<br>**PROTECTION**<br>232*81*31mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>4.85A/115VAC 2.6A/230VAC<br>**RATED POWER**<br>0.905kg; 16pcs/15.48kg/0.82CUFT<br>47 ~ 63Hz<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>4.5~5.5V<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>5V<br>11.4~12.6V<br>±0.5%<br>±0.3%<br>±1.0%<br>200mVp-p<br>12V<br>14.3~15.8V<br>200mVp-p<br>15V<br>22.8~25.2V<br>240mVp-p<br>24V<br>34.2~37.8V<br>360mVp-p<br>36V<br>45.6~50.4V<br>360mVp-p<br>48V<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>**UHP-500 -5**<br>**UHP-500 -12**<br>**UHP-500 -15 UHP-500 -24**<br>**UHP-500 -36**<br>**UHP-500 -48**<br>**FUNCTION**<br>**REDUNDANT(Optional)**<br>Contact rating(max.):30Vdc/1A resistive load<br>For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system<br>**DC OK SIGNAL(Optional)**<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to EN55032,GB/T9254,Class B, EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020<br>UL 62368-1,TUV EN62368-1,EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1, EAC TP TC 004 approved;Design refer to EN61558-2-16<br>80A<br>336W<br>80A<br>400W<br>41.7A<br>500.4W<br>33.4A<br>501W<br>20.9A<br>501.6W<br>13.9A<br>500.4W<br>501.6W<br>10.45A<br>**UHP-500 -55**<br>45~58V<br>500mVp-p<br>55V<br>±0.5%<br>±0.3%<br>±1.0%<br>500W<br>8.9A<br>89%<br>95%<br>94%<br>94%<br>94.5%<br>95%<br>90%<br>95%<br>60 ~ 69V<br>**INRUSH CURRENT (Typ.)Note9**<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance ‘includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5.<br>ambient temperature derating of 3.5<br>/1000m is needed for operating altitude greater than 2000m(6500ft)<br>6.<br>For guidance on how to perform these EMC tests,<br>please refer to “EMI testing of component power supplies.” (as available on http:/www.meanwell.com)<br>7. Please refer to derating currve.<br>8. R type efficiency slightly less than the Blank type, according to the actual measurement.<br>9.Inrush current parameter has 10% tolerance.|**UHP-500 -4.2**|**UHP-500 -5**|**UHP-500 -12**|**UHP-500 -15 **|**UHP-500 -24**|**UHP-500 -36**|**UHP-500 -48**|**UHP-500 -55**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|4.2V|5V|12V|15V|24V|36V|48V|55V| ||**RATED CURRENT**|80A|80A|41.7A|33.4A|20.9A|13.9A|10.45A|8.9A| ||**RATED POWER**|336W|400W|500.4W|501W|501.6W|500.4W|501.6W|500W| ||**RIPPLE & NOISE (max.) Note.2**|200mVp-p|200mVp-p|200mVp-p|200mVp-p|240mVp-p|360mVp-p|360mVp-p|500mVp-p| ||**VOLTAGE ADJ. RANGE Note.7**|3.6~4.4V|4.5~5.5V|11.4~12.6V|14.3~15.8V|22.8~25.2V|34.2~37.8V|45.6~50.4V|45~58V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.3%|±0.3%|±0.3%|±0.3%|±0.3%|±0.3%| ||**LOAD REGULATION**|±1.0%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time|||||||| ||**HOLD UP TIME (Typ.)**|12ms/230VAC 12ms/115VAC|||||||| ||**VOLTAGE RANGE Note.4**|90 ~ 264VAC 127 ~ 370VDC|||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||||| ||**POWER FACTOR (Typ.)**|PF<br>0.95/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥|||||||| ||**EFFICIENCY (Typ.)**|89%|90%|94%|94%|94.5%|95%|95%|95%| ||**AC CURRENT (Typ.)**|4.85A/115VAC 2.6A/230VAC|||||||| ||**INRUSH CURRENT (Typ.)Note9**|Cold start 30A/115VAC 60A/230VAC|||||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC|||||||| ||**OVERLOAD**|110~140% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||||| ||**OVER VOLTAGE**|4.62 ~ 5.46V<br>Protection type :Shut down O/P voltage,re-power on to recover<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>60 ~ 69V|||||||| ||**OVER TEMPERATURE**|Protection type :Shut down O/P voltage, recovers automatically after temperature goes down|||||||| ||**DC OK SIGNAL(Optional)**|Contact rating(max.):30Vdc/1A resistive load|||||||| ||**REDUNDANT(Optional)**|For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system|||||||| ||**WORKING TEMP.**|-30 ~ +70<br>(Refer to “Derating Curve")<br>℃|||||||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50|||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||||| ||**SAFETY STANDARDS**|UL 62368-1,TUV EN62368-1,EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1, EAC TP TC 004 approved;Design refer to EN61558-2-16|||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC|||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25<br>/ 70%RH<br>℃|||||||| ||**EMC EMISSION**|Compliance to EN55032,GB/T9254,Class B, EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020|||||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020|||||||| ||**MTBF**|168K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||||||| ||**DIMENSION**|232*81*31mm (L*W*H)|||||||| ||**PACKING**|0.905kg; 16pcs/15.48kg/0.82CUFT|||||||| ||℃<br>℃<br>The<br>The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives.<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance ‘includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5.<br>ambient temperature derating of 3.5<br>/1000m is needed for operating altitude greater than 2000m(6500ft)<br>6.<br>For guidance on how to perform these EMC tests,<br>please refer to “EMI testing of component power supplies.” (as available on http:/www.meanwell.com)<br>7. Please refer to derating currve.<br>8. R type efficiency slightly less than the Blank type, according to the actual measurement.<br>9.Inrush current parameter has 10% tolerance.||||||||| > The ambient temperature derating of 3.5 ℃ /1000m is needed for operating altitude greater than 2000m(6500ft) The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. _File Name:UHP-500-SPEC 2020-08-24_ **UHP - 500 series** ## 500W Slim Type with PFC Switching Supply **==> picture [78 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>**----- End of picture text -----**<br> **==> picture [501 x 603] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc:60KHz<br>PWM fosc:65KHz~75KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & SWITCH- &<br>RECTIFIER CIRCUIT ING FILTER -V<br>FG DETECTION<br>CIRCUIT<br>O.T.P. O.L.P.<br>CONTROL<br>O.V.P.<br>DC OK Function<br>Redundant Function<br>Derating Curve<br>12V,15V 230Vac for 12V,15V<br>100 others 100 230Vac for other<br>90<br>230Vac for 4.2V,5V<br>80 4.2V,5V 80 110Vac for other 230Vac for 55V<br>70<br>60 60 110Vac for 4.2V,5V<br>50<br>40 40<br>30<br>20 20 110Vac for 55V<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) -30 0 10 20 30 40 45 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE( )<br>100<br>80<br>60<br>40<br>20<br>-30 0 10 20 30 40 50 60 70 80 90 (HORIZONTAL)<br>Tcase ( )<br> (%)<br>RATED CURRENT RATED CURRENT (%)<br>RATED CURRENT (%)<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2020-08-24_ **UHP - 500 series** 500W Slim Type with PFC Switching Supply ## **STATIC CHARACTERISTIC** **==> picture [196 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 100 110 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **DC OK Relay Contact** |Contact Close|PSU turns on/DC ok| |---|---| |Contact Open|PSU turns off/DC fail| |Contact Rating(max.)|30Vdc/1A resistive load| ## **Redundant function** (1) UHP-500R is built-in redundant function and can be connected 2 units in parallel . (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU. **==> picture [159 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> +V<br>+V<br>PSU -V -V LOAD<br>+V<br>PSU -V<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2020-08-24_ 500W Slim Type with PFC Switching Supply ## **UHP - 500 series** **==> picture [422 x 239] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>232<br>226 3<br>TB3<br>1<br>TB1<br>3 2<br>2<br>3<br>1 TB2<br>4<br>CN1<br>SVR<br>4-ψ4.2 L=6<br>9<br>63 81<br>9.0<br>7.62<br>2 1<br>**----- End of picture text -----**<br> CASE NO.:233D Unit:mm **==> picture [372 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> 116<br>t c<br>�tc : Max. Case Temperature<br>15.5<br>31<br>**----- End of picture text -----**<br> AC Input Terminal(TB1) pin NO. Assignment DC Output Terminal(TB2,TB3) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque Pin No. Assignment Terminal Max mounting torque 1 AC/L 2 AC/N DG28C(DEGSON)B 03P 5Kgf-cm 13,4,2 +V-V MEL-400-02P(MW) 8Kgf-cm 3 DC OK Connector(CN1):JST B2B-PH-K-S or requivalent Pin No. Assignment Mating Housing Terminal 1 DC COM1 JST PHR-2 JST SPH-002T-P0.5S 2 DC COM2 or requivalent or requivalent _File Name:UHP-500-SPEC 2020-08-24_ **UHP - 500 series** ## 500W Slim Type with PFC Switching Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Installation<br>1.Operate with additional aluminum plate<br>In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-500 series must be installed onto an aluminum plate(or the cabinet of the same size)<br>on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and<br>smooth surface (or coated with thermal grease), and UHP-500 series must be firmly mounted at the center of the aluminum plate.<br>unit:mm<br>M3*4<br>450<br>450<br>3<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2020-08-24_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →