TXN 50-112
AC/DC Enclosed Power Supply (PSU), ITE & Industrial, 1 Outputs, 50 W, 12 V, 4.2 A
- Manufacturer: TRACO POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (27-Jun-2024)
- Product Range: TXN 50 Series
- No. of Outputs: 1Outputs
- Output Power Max: 50W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 9.94 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TXN 50 Series, 50 Watt** ## **AC/DC Industrial Power Supply** - **Compact metal case with screw terminal block** - **Universal input 90-264 VAC** - **High efficiency up to 86%** - **Compliance to EN 61000-3-2** - **Short circuit, overvoltage and overload protection** - **IEC/EN/UL 62368-1 safety approvals** - **3-year product warranty** UL 62368-1 IEC 62368-1 The new TXN line comprises a series of cost efficient, metal enclosed AC/DC power supplies and is designed for industrial applications. With a low-profile metal case and screw terminal block connection, they are easy to install in any equipment. The TXN power supplies are completely convection cooled. Internal EMC filter, high IO-isolation and wide temperature range qualify them for numerous industrial applications. These power supplies have universal input and comply with the latest industrial standard IEC/EN/UL 62368-1, European EMC standards and the Low Voltage Directive (LVD). ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TXN 50-103**<br>**TXN 50-105**<br>**TXN 50-112**<br>**TXN 50-115**<br>**TXN 50-124**<br>**TXN 50-148**|33 W|3.3 VDC(2.9 - 3.6 VDC)<br>5 VDC(4.5 - 5.5 VDC)<br>12 VDC(10.8 - 13.2 VDC)<br>15 VDC(13.5 - 16.5 VDC)<br>24 VDC(21.6 - 26.4 VDC)<br>48 VDC(44.0 - 52.0 VDC)|10'000 mA<br>10'000 mA<br>4'200 mA<br>3'400 mA<br>2'100 mA<br>1'100 mA|84 %<br>83 %<br>85 %<br>85 %<br>85 %<br>86 %| ||50 W|||| ## **Options** **on demand** (backorder with MOQ - Optional model with 36 VDC and 1'400 mA non stocking item) **Page 1 / 4** **September 3, 2024** **www.tracopower.com** **TXN 50 Series, 50 Watt** ## **Input Specifications** Input Voltage - AC Range Operational Range: 90 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 140 - 340 VDC (Designed for, no certification) Polarity: +DC: L / –DC: N Input Frequency Operational Range: 47 - 63 Hz Certified: 50/60 Hz Power Consumption - No load & Vin = 230 VAC 1 W max. - No load & Vin = 115 VAC 1 W max. Input Current - Full load & Vin = 230 VAC 550 mA max. - Full load & Vin = 115 VAC 1 A max. Input Inrush Current - At 230 VAC 60 A max. - At 115 VAC 30 A max. Input Protection T 3.15 A / 250VAC (Internal Fuse in L) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) ## **Output Specifications** Output Voltage Adjustment |Output Voltage Adjustment||±8%(36 & 48 Vout output models)| |---|---|---| |||±10%(other output models)| |||(By trim potentiometer)| |||Outputpower must not exceed ratedpower!| |Voltage Set Accuracy||±2% max.(3.3 & 5 Vout models)| |||±1% max.(other models)| |Regulation|- Input Variation (Vmin - Vmax)|0.5% max.| ||- Load Variation (0 - 100%)|2% max.(3.3 & 5 Vout models)| |||1% max.(other models)| |Ripple and Noise||3.3 VDC model: 80 mVp-p max.(w/ 0.1 µF || 47 µF)| |(20 MHz Bandwidth)||5 VDC model: 100 mVp-p max.(w/ 0.1 µF || 47 µF)| |||12 VDC model: 120 mVp-p max.(w/ 0.1 µF || 47 µF)| |||15 VDC model: 120 mVp-p max.(w/ 0.1 µF || 47 µF)| |||24 VDC model: 120 mVp-p max.(w/ 0.1 µF || 47 µF)| |||36 VDC model: 200 mVp-p max.(w/ 0.1 µF || 47 µF)| |||48 VDC model: 200 mVp-pmax. (w/ 0.1µF||47µF)| |Minimum Load||Not required| |Temperature Coefficient||±0.03 %/K max.| |Hold-up Time|- At 230 VAC|20 ms min.| ||- At 115 VAC|30 ms min.| |Start-up Time|- At 230 VAC|2.5 s max.| ||- At 115 VAC|700 ms max.| |Start-upOvershoot Voltage||5% max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||110 - 160% of Iout max.| |Overvoltage Protection||110 - 130% of Vout nom.| ## **Safety Specifications** |Standards|- IT / Multimedia Equipment|EN 62368-1| |---|---|---| |||IEC 62368-1| |||UL 62368-1| |Protection Class||Class I(Prepared): Connection to PE| |Pollution Degree||PD 2| |Over Voltage Category||OVC III| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 4** **September 3, 2024** **www.tracopower.com** **TXN 50 Series, 50 Watt** ## **EMC Specifications** EMI (Emissions) - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class A - Voltage Fluctuations & Flicker EN 61000-3-3 EMS (Immunity) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria B Contact: EN 61000-4-2, ±4 kV, perf. criteria B - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria B - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria B L to L: EN 61000-4-5, ±1 kV, perf. criteria B L to PE: EN 61000-4-5, ±2 kV, perf. criteria B - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria B - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C EMC / Environmental - Certification Documents www.tracopower.com/overview/txn50 ## **General Specifications** |Relative Humidity||95% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|–30°C to +70°C| ||- Storage Temperature|–30°C to +80°C| |Power Derating|- High Temperature|2 %/K above 50°C(High Temperature)| |||2.0 %/K below –25°C(Low Temperature)| ||- Low Input Voltage|2 %/V below 100 VAC| |||See application note: www.tracopower.com/overview/txn50| |CoolingSystem||Natural convection(20 LFM)| |Altitude DuringOperation||5'000 m max.| |Regulator Topology||Flyback Converter| |SwitchingFrequency||65 kHz typ. (PWM)| |Insulation System||Reinforced Insulation| |WorkingVoltage (rated)||540 VAC| |Isolation Test Voltage|- Input to Output, 60 s|3'000 VAC| ||- Input to Case or PE, 60 s|1'500 VAC| ||- Output to Case or PE, 60 s|500 VAC| |Creepage|- Input to Output|7.3 mm min.| ||- Input to Case or PE|3.2 mm min.| ||- Output to Case or PE|2 mm min.| |Clearance|- Input to Output|6.1 mm min.| ||- Input to Case or PE|3.2 mm min.| ||- Output to Case or PE|2 mm min.| |Isolation Resistance|- Input to Output,500 VDC|100 MΩ min.| |Isolation Capacitance|- Input to Output,100 kHz,1 V|1'000pF max.| |Leakage Current|- Earth Leakage Current|750 µA max.| |(at 240 VAC / 60 Hz)||| |Reliability|- Calculated MTBF|(tbd)| |WashingProcess||Not allowed| |Environment|- Vibration|2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle| ||- Mechanical Shock|20 g, 3 axis, 3 shocks| |Case Ingress Protection||IP 20(acc. IEC 60529)| |HousingMaterial||Aluminum(Chassis)| |HousingType||Metal Case| |MountingType||Chassis Mount| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 4** **September 3, 2024** **www.tracopower.com** **TXN 50 Series, 50 Watt** Connection Type Weight Status Indicator Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number Screw Terminal 200 g Indicated by green LED www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) d043d24d-bd1f-4022-8bcb-23643dd4338a ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/txn50 ## **Outline Dimensions** **==> picture [265 x 292] intentionally omitted <==** **----- Start of picture text -----**<br> 26<br>Vout adjustment<br>Status indicator 9.5 5.5 15<br>5 4 3 2 1 Ø3.5<br>Ø3.5<br>2-M3, L=5<br>2-M3, L=5<br>3.5 41.5 3.5<br>75.5 14.5<br>82±0.5 30±0.5<br>Dimensions in mm<br>Terminal screw tightening torque: Max. 1.0 Nm<br>Mounting screw tightening torque: Max. 0.8 Nm<br>Mounting screw penetration depth: Max. 3 mm<br>Mounting screw length: Max. 5 mm<br>4.5 10 6.5<br>20.5<br>55 92.5 74 90<br>99±0.5<br>**----- End of picture text -----**<br> |Pinout|Pinout| |---|---| |Pin<br>1|Function<br>AC (L)| |2<br>3|<br>AC (N)<br>PE| |4|out| |5|+Vout| Wiring: Conductor cross section 0.5 .. 3 mm[2] © Copyright 2024 Traco Electronic AG Specifications can be changed without notice. Rev. September 3, 2024 www.tracopower.com **Page 4 / 4**
Updated at June 7, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →