TR-50222-05
TIME DELAY RELAY, DPDT, 10S, 240VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MACROMATIC CONTROLS
- Product type: Time Delay Relays - Electromechanical
- Contact Voltage VDC:30V; Time Min:0.1s; Time Max:10s; Product Range:TR-5 Series; Contact Configuration:DPDT; Contact Current:10A; Relay Mounting:Socket; Contact Vo 48F5942
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 10s
- Time Min: 0.1s
- Product Range: TR-5 Series
- Relay Mounting: Socket
- Contact Current: 10A
- Relay Terminals: Quick Connect
- Nom Input Voltage: 120V
- Timing Adjustment: Knob
- Contact Voltage VAC: 240V
- Contact Voltage VDC: 30V
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 61.53 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **NON-PROGRAMMABLE | ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER**
## **TR-5 Series**
- Onboard & remote adjustable or fi xed time delays from 0.05 seconds to 2 hours
- Uses industry-standard 8 pin octal sockets
- 10A DPDT output contacts
|**FUNCTION**<br>**ON DELAY**|**INPUT VOLTAGE**<br>**50/60Hz.**<br>120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC|**PRODUCT**<br>**NUMBER ****<br>TR-50222-**<br>TR-50226-**<br>TR-50228-**<br>TR-50221-**|**WIRING/**<br>**SOCKETS**<br>8 PIN OCTAL<br>**70169-D**<br>**DIAGRAM 1**<br>vey<br>i|
|---|---|---|---|
|**INTERVAL ON**<br>~~pefo]~~|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC<br>~~fo]~~|TR-50522-**<br>TR-50526-**<br>TR-50528-**<br>TR-50521-**<br>~~fo]~~||
|**TRUE OFF DELAY**<br>~~pefo]~~|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC<br>~~fo]~~|TR-50622-**<br>TR-50626-**<br>TR-50628-**<br>TR-50621-**<br>~~fo]~~||
|**FLASHER**<br>(OFF 1st)<br>~~pe fo]~~|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC<br>~~fo]~~|TR-50822-**<br>TR-50826-**<br>TR-50828-**<br>TR-50821-**<br>~~fo]~~||
with appropriate socket
- See “Defi nitions of Timing Functions”.
- ** Complete Product Number using two-digit Code from Table below.
- Note: If these products are ordered with the Remote Adjustable Time Delay modifi cation (suffi x -Rx), they will require an 11 pin octal socketsee _**www.macromatic.com/remote**_ for information. Remote Adjustable Time Delay not available on TR-506 products.
## **Time Delays**
**800.238.7474 www.macromatic.com sales@macromatic.com**
|**Time Delays**|||
|---|---|---|
|TR-5 Series Products have three time delay options:|||
|**Onboard Adjustable Time Delay**--complete<br>Product Number by adding two-digit Code from|**** TIMING RANGE TABLE**|**TIMING RANGE TABLE**|
|Table at right, i.e., TR-50222-05 is an On Delay|**Time Delay Range**|**Code**|
|with a time delay range of 0.1-10 seconds.<br>**Onboard Fixed Time Delay**--replace two-digit<br>Code with suffi x “F” followed by delay [0.1 ...<br>100] followed by (S) seconds, (M) minutes or (H)<br>hours, i.e., TR-50222-F5S is an On Delay with a<br>time delay fi xed at 5 seconds.<br>**Remote Adjustable Time Delay**--Selected TR-5<br>Series products can be built with two terminals|0.05 - 5 Sec.<br>0.1 - 10 Sec.<br>0.3 - 30 Sec.<br>0.6 - 60 Sec.<br>1.2 - 120 Sec.<br>1.8 - 180 Sec.<br>3 - 300 Sec.<br>0.1 - 10 Min.<br>0.3 - 30 Min.|04<br>05<br>07<br>08<br>09<br>10<br>12<br>22<br>15|
|for remote adjustable or fi xed time delays. See<br>**_www.macromatic.com/remote_** for information.|0.6 - 60 Min.<br>1.2 - 120 Min.|16<br>17|
Not offered on TR-506
## **Sockets & Accessories available**
**Build your Time Delay Relays with the** _**Online Product Builder**_
18
## **NON-PROGRAMMABLE | OFF DELAY, SINGLE SHOT, WATCHDOG & SINGLE SHOT FALLING EDGE TR-5 Series**
**INPUT VOLTAGE PRODUCT WIRING/ FUNCTION** **50/60Hz. NUMBER ** SOCKETS** **OFF DELAY** 120V AC/DC TR-51622-** 11 PIN OCTAL Control Switch Trigger 12V DC TR-5162670170-D** 24V AC/DC TR-51628-** TRIGGER 240V AC TR-51621-** , ¢ **SINGLE SHOT** 120V AC/DC TR-51522-** Control Switch Trigger 12V DC TR-51526-** viet Tks 24V AC/DC TR-51528-** a 3 ® ia 240V AC TR-51521WATCHDOG** 120V AC/DC TR-51322-** ~w Oo ty =—O ~~ Control Switch Trigger 12V DC TR-51326-** (Retriggerable 24V AC/DC TR-51328DIAGRAM 2** Single Shot) 240V AC TR-51321SINGLE SHOT** 120V AC/DC TR-52222FALLING EDGE** 12V DC TR-52226-** Control Switch Trigger 24V AC/DC TR-52228-** 240V AC TR-52221OFF DELAY** 120V AC/DC TR-51922-** 11 PIN OCTAL Power Trigger 12V DC TR-5192670170-D** 24V AC/DC TR-51928-** 240V AC TR-51921-** ~~Poe |~~ +] TRIGGER’ J- **SINGLE SHOT** 120V AC/DC TR-51722-** Power Trigger 12V DC TR-51726-** x 7 5 87 ser 24V AC/DC TR-51728-** 240V AC TR-51721-** 141 **WATCHDOG** 120V AC/DC TR-51822-** Power Trigger 12V DC TR-51826-** * MUST BE SAME VOLTAGE (Retriggerable 24V AC/DC TR-51828-** AS INPUT VOLTAGE Single Shot) 240V AC TR-51821DIAGRAM 4** | ~~off~~ a See “Defi nitions of Timing Functions”. ** Complete Product Number using two-digit Code from Table below.
- Onboard & remote adjustable or fi xed time delays from 0.05 seconds to 2 hours
- Uses industry-standard 11 pin octal sockets
- 10A DPDT output contacts
with appropriate socket
- 8 Pin SPDT versions of these functions (except Single Shot Falling Edge) are available
## **Time Delays**
TR-5 Series Products have three time delay options:
- **Onboard Adjustable Time Delay** --complete **** TIMING RANGE TABLE** Product Number by adding two-digit Code from Table at right, i.e., TR-51622-05 is an Off Delay **Time Delay Range Code** 0.05 - 5 Sec. 04
- with a time delay range of 0.1-10 seconds. 0.1 - 10 Sec. 05
- **Onboard Fixed Time Delay** --replace two-digit 0.3 - 30 Sec. 07 Code with suffi x “F” followed by delay [0.1 ... 0.6 - 60 Sec. 08 100] followed by (S) seconds, (M) minutes or (H) 1.2 - 120 Sec. 09 hours, i.e., TR-51622-F5S is an Off Delay with a 1.8 - 180 Sec. 10 time delay fi xed at 5 seconds. 3 - 300 Sec. 12
- **Remote Time Delay** --Selected TR-5 Series 0.1 - 10 Min. 22 products can be built with two terminals for 0.3 - 30 Min. 15 remote adjustable or fi xed time delays. See 0.6 - 60 Min. 16 1.2 - 120 Min. 17
- _**www.macromatic.com/remote**_ for information.
**Build your Time Delay Relays with the** _**Online Product Builder**_
**800.238.7474 www.macromatic.com sales@macromatic.com**
**Sockets & Accessories available**
19
## **NON-PROGRAMMABLE | REPEAT CYCLE, ON/OFF DELAY, & DELAYED INTERVAL**
## **TR-5 Series**
**INPUT VOLTAGE PRODUCT WIRING/ FUNCTION** **50/60Hz. NUMBER ** SOCKET REPEAT CYCLE*** 120V AC/DC TR-53122-** (OFF Time First Followed 12V DC TR-53126-** 8 PIN OCTAL By ON Time 24V AC/DC TR-5312870169-D** and Repeating) 240V AC TR-53121ON/TRUE OFF DELAY** 120V AC/DC TR-54622-** 12V DC TR-54626-** = a Je 24V AC/DC TR-54628-** My 8) ty Onboard & remote adjustable 240V AC TR-54621-** or fi xed time delays from 0.05 **REPEAT CYCLE*** 120V AC/DC TR-55122-** seconds to 2 hours (ON Time First Followed 12V DC TR-55126DIAGRAM 1** By OFF Time 24V AC/DC TR-55128-** Independently adjustable ON & and Repeating) 240V AC TR-55121-** OFF times ~~al | _—~~ **DELAYED INTERVAL*** 120V AC/DC TR-56122-** Uses industry-standard 8 or 11 (OFF Time Followed by 12V DC TR-56126-** 11 PIN OCTAL pin octal sockets ON Time Followed by OFF 24V AC/DC TR-5612870170-D** 10A DPDT output contacts State Until Reset) 240V AC TR-56121-** . ~~wt~~ **ON/OFF DELAY*** 120V AC/DC ~~|~~ TR-54122-** e TRIGGER Ak[is][@-] Control Switch Trigger 12V DC TR-54126-** vy fee 6 80 y 24V AC/DC TR-54128-** with appropriate 240V AC TR-54121-** socket **DELAYED INTERVAL*** 120V AC/DC TR-56522-** Control Switch Trigger 12V DC TR-56526-** (OFF Time Followed by 24V AC/DC TR-56528DIAGRAM 2** ON Time Followed by OFF 240V AC TR-56521-** State Until Reset) ~ ~~8~~ pf -_Vv See “Defi nitions of Timing Functions”. * ON & OFF Time Ranges for these functions are the same. See _**www.macromatic.com/onoff**_ for information on how to order a unit with different ON & OFF time ranges.
- ** Complete Product Number using two-digit Code from Table below.
## **Time Delays**
- TR-5 Series Products have three time delay options:
**800.238.7474 www.macromatic.com sales@macromatic.com**
- **Onboard Adjustable Time Delay** --complete Product Number by adding two-digit Code from Table at right, i.e., TR-53122-05 is a Repeat Cycle with both an ON & OFF time delay range of 0.1-10 seconds. See _**www.macromatic.com/onoff**_ for information on how to order a unit with different ON & OFF time ranges.
||**** TIMING RANGE TABLE**<br>**Time Delay Range**<br>0.05 - 5 Sec.<br>0.1 - 10 Sec.|**TIMING RANGE TABLE**<br>**Code** <br>04<br>05|
|---|---|---|
||0.3 - 30 Sec.|07|
|0.1 - 10 Min.|0.6 - 60 Sec.<br>1.2 - 120 Sec.<br>1.8 - 180 Sec.<br>3 - 300 Sec.<br>0.1 - 10 Min.<br>0.3 - 30 Min.|08<br>09<br>10<br>12<br>22<br>15|
||0.6 - 60 Min.<br>1.2 - 120 Min.|16<br>17|
- **Onboard Fixed Time Delay** --replace two-digit Code with suffi x “F” followed by delay [0.1 ... 100] followed by (S) seconds, (M) minutes or (H) hours, i.e., TR53122-F5S is a Repeat Cycle with a time delay fi xed at 5 seconds.
- **Remote Time Delay** --Selected TR-5 Series products can be built with two terminals for remote adjustable or fi xed time delays.
Not offered on TR-546
- See _**www.macromatic.com/remote**_ for information.
## **Sockets & Accessories available**
**Build your Time Delay Relays with the** _**Online Product Builder**_
20
## **TR-5 SERIES Non-Programmable**
## **Application Data**
## **Voltage Tolerance:**
AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal.
## **Load (Burden):**
Maximum of 2 VA for all voltages
## **Setting Accuracy:**
Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +2% or 50ms, whichever is greater
**Repeat Accuracy** (constant voltage and temperature) **:** +0.1% or + 0.04 seconds, whichever is greater
## **Reset Time:**
Input Voltage (All Functions) 0.100 Seconds Triggered Functions only 0.04 Seconds
## **Start-up Time:**
(Time from when power is applied until unit is timing) 0.05 Seconds
## **Maintain Function Time:**
(Time unit continues to operate after power is removed) 0.01 Seconds for all units
**Temperature:** Operating: -28[o] to 65[o] C (-18[o] to 149[o] F) Storage: -40[o] to 85[o] C (-40[o] to 185[o] F)
## **Life:**
Mechanical: 10,000,000 operations (2,000,000 operations on TR-506 & TR-546 Series only) Full Load: 100,000 operations
## **Compatibility:**
Using a solid state switch to initiate the time sequence is acceptable. See _**www.macromatic.com/leakage**_ or contact Macromatic for information regarding leakage current limits and other solid state design considerations.
## **Triggering Off Delay, Single Shot or Watchdog Units:**
Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.05 seconds.
## **IMPORTANT FOR TR-506 & TR-546 SERIES ONLY:** These
relays are shipped from the factory in the OFF state. A shock to the relay during shipping or installation may cause it to change to the ON state. It is recommended that input voltage be applied to the product for at least 0.1 second and removed to cycle the unit to the OFF state prior to use in the application. Please note that it will take as long as the OFF Delay setting to reset the unit once input voltage has been removed.
## **Approvals:**
(All TR-5 Series Products except TR-506 & TR-546)
**==> picture [98 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
File #E109466 File #LR45565<br>**----- End of picture text -----**<br>
## **Output Contacts:**
(All TR-5 Series Products except TR-506 & TR-546) DPDT 10A @ 240V AC/30V DC,
1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.) B300 & R300; AC15 & DC13
(TR-506 & TR-546) DPDT 10A @ 240V AC; 8A @ 28V DC, 1/2 HP @ 240V AC, 1/4HP @ 120V AC B300 & R300
(TR-506 & TR-546 only)
**==> picture [225 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
File #E109466<br>(All TR-5 Series<br>Products)<br>Low Voltage &<br>with<br>EMC Directives<br>appropriate<br>EN60947-1, EN60947-5-1 socket<br>File #E109466<br>**----- End of picture text -----**<br>
## **Dimensions**
**==> picture [275 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.4<br>(60)<br>2.9<br>(74)<br>1.7 3.5<br>(43) (89)<br>All Dimensions in<br>Inches (Millimeters)<br>**----- End of picture text -----**<br>
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
21
## **NON-PROGRAMMABLE | OFF DELAY, SINGLE SHOT & WATCHDOG**
## **8 Pin | SPDT Versions | TR-5 Series**
- These are 8 pin 10A SPDT versions of our standard 11 pin DPDT products
- Onboard & remote adjustable or fi xed time delays from 0.05 seconds to 2 hours
- Uses industry-standard 8 pin octal socket AW: G CE with appropriate socket
||**INPUT**|||
|---|---|---|---|
|**FUNCTION**<br>**OFF DELAY**<br>Control Switch Trigger|**VOLTAGE**<br>**50/60Hz.**<br>120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC|**PRODUCT**<br>**NUMBER ****<br>TR-51662-**<br>TR-51666-**<br>TR-51668-**<br>TR-51661-**|**WIRING/**<br>**SOCKETS**<br>8 PIN OCTAL<br>**70169-D**<br>**DIAGRAM 11**<br>cys<br>~<br>TO: @<br>«<br>ve<br>~ Oo+Vv =—O~N|
|**SINGLE SHOT**<br>Control Switch Trigger|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC|TR-51562-**<br>TR-51566-**<br>TR-51568-**<br>TR-51561-**||
|**WATCHDOG**<br>Control Switch Trigger<br>(Retriggerable<br>Single Shot)|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC|TR-51362-**<br>TR-51366-**<br>TR-51368-**<br>TR-51361-**||
|**OFF DELAY**<br>Power Trigger|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC|TR-51962-**<br>TR-51966-**<br>TR-51968-**<br>TR-51961-**|8 PIN OCTAL<br>**70169-D**<br>**DIAGRAM 37**<br>Lal<br>pie So<br>1°7»<br>marr<br>* MUST BE SAME VOLTAGE<br>AS INPUT VOLTAGE|
|**SINGLE SHOT**<br>PowerTrigger<br>~~ow~~|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC<br>~~ow~~|TR-51762-**<br>TR-51766-**<br>TR-51768-**<br>TR-51761-**||
|**WATCHDOG**<br>Power Trigger<br>(Retriggerable<br>Single Shot)<br>~~ow~~|120V AC/DC<br>12V DC<br>24V AC/DC<br>240V AC<br>~~ow~~<br>||TR-51862-**<br>TR-51866-**<br>TR-51868-**<br>TR-51861-**||
- Note: if these products are ordered with the Remote Adjust Potentiometer modifi cation (suffi x -Rx), they will require an 11 pin octal socketsee _**www.macromatic.com/remote**_ for information.
## **Time Delays**
**800.238.7474 www.macromatic.com sales@macromatic.com**
- TR-5 Series Products have three time delay options: **Onboard Adjustable Time Delay** --complete Product Number by adding two-digit Code from Table at right, i.e., TR-51662-05 is an Off Delay with a time delay range of 0.1-10 seconds.
## **** TIMING RANGE TABLE**
|**Time Delay Range**<br>0.1 - 10 Sec.|**Time Delay Range**<br>0.05 - 5 Sec.<br>0.1 - 10 Sec.<br>0.3 - 30 Sec.<br>0.6 - 60 Sec.<br>1.2 - 120 Sec.|**Code**<br>04<br>05<br>07<br>08<br>09|
|---|---|---|
||1.8 - 180 Sec.|10|
||3 - 300 Sec.|12|
|0.1 - 10 Min.|0.1 - 10 Min.<br>0.3 - 30 Min.<br>0.6 - 60 Min.<br>1.2 - 120 Min.|22<br>15<br>16<br>17|
- **Onboard Fixed Time Delay** --replace two-digit Code with suffi x “F” followed by delay [0.1 ... 100] followed by (S) seconds, (M) minutes or (H) hours, i.e., TR-51662-F5S is an Off Delay with a time delay fi xed at 5 seconds.
- **Remote Time Delay** --Selected TR-5 Series products can be built with two terminals for remote adjustable or fi xed time delays. See _**www.macromatic.com/remote**_ for information.
## **Sockets & Accessories available**
**Build your Time Delay Relays with the** _**Online Product Builder**_
22
## **TR-5 SERIES 8 Pin | SPDT Versions**
## **Application Data**
## **Voltage Tolerance:**
AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal.
## **Load (Burden):**
Maximum of 2 VA for all voltages
## **Setting Accuracy:**
Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +2% or 50ms, whichever is greater
**Repeat Accuracy** (constant voltage and temperature) **:** +0.1% or + 0.04 seconds, whichever is greater
## **Reset Time:**
Input Voltage (All Functions) 0.100 Seconds Triggered Functions only 0.04 Seconds
## **Start-up Time:**
(Time from when power is applied until unit is timing) 0.05 Seconds
## **Maintain Function Time:**
**Temperature:** Operating: -28[o] to 65[o] C (-18[o] to 149[o] F) Storage: -40[o] to 85[o] C (-40[o] to 185[o] F)
## **Output Contacts:**
SPDT 10A @ 240V AC/30V DC, 1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.) B300 & R300; AC15 & DC13
## **Life:**
Mechanical: 10,000,000 operations Full Load: 100,000 operations
## **Compatibility:**
Using a solid state switch to initiate the time sequence is acceptable. See _**www.macromatic.com/leakage**_ or contact Macromatic for information regarding leakage current limits and other solid state design considerations.
## **Triggering Off Delay, Single Shot or Watchdog Units:**
Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.05 seconds.
## **Approvals:**
(Time unit continues to operate after power is removed) 0.01 Seconds for all units
**==> picture [246 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
File #E109466 File #LR45565 Low Voltage &<br>with<br>EMC Directives<br>appropriate<br>EN60947-1, EN60947-5-1 socket<br>File #E109466<br>**----- End of picture text -----**<br>
## **Dimensions**
**==> picture [354 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.4<br>(60)<br>2.9<br>@ 4 (74) +<br>1.7 3.5<br>(43) (89)<br>a ———s<br>All Dimensions in<br>Inches (Millimeters)<br>**----- End of picture text -----**<br>
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
23
## **DEFINITION OF TIMING FUNCTIONS**
Understanding the differences between all the functions available in time delay relays can sometimes be a daunting task. To begin with, time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time.
Typically, time delay relays are initiated or triggered by one of two methods, depending on the function:
- application of input voltage
- application of a trigger
These triggers can be one of two signals: a control switch (dry contact), i.e., limit switch, push button, fl oat switch, etc., or voltage (commonly known as a power trigger).
## **CAUTION: any time delay relay that is designed to be initiated with a dry contact control switch trigger could be damaged if voltage is applied to the trigger switch terminals. Only products that have a “power trigger” should be used with voltage as the trigger.**
To help understand, some defi nitions are important:
- Input Voltage - control voltage applied to the input terminals. Depending on the function, input voltage will either initiate the unit or make it ready to initiate when a trigger is applied.
- Trigger- on certain timing functions, a trigger is used to initiate the unit after input voltage has been applied. As noted above, this trigger can either be a control switch (dry contact switch) or a power trigger (voltage).
- Output (Load) - every time delay relay has an output (either mechanical relay or solid state) that will open & close to control the load. Note that the user must provide the voltage to power the load being switched by the output contacts of the time delay relay. In all wiring diagrams, the output is shown in the normal de-energized position.
Below and on the following pages are both written and visual descriptions on how the common timing functions operate. A Timing Chart shows the relationship between Input Voltage, Trigger (if present) and Output. If you cannot fi nd a product to fi t your requirements or have any questions, Macromatic’s Application Engineers offer technical information along with product selection and application assistance. Call us at 800-238-7474 or e-mail us tech-help@macromatic.com.
|**Function/Code**|**Operation**|**Timing Chart**|
|---|---|---|
|**ON DELAY**<br>Delay on<br>Operate<br>Delay on Make|Upon application of input voltage, the time delay (t)<br>begins. At the end of the time delay (t), the output is<br>energized. Input voltage must be removed to reset the<br>time delay relay & de-energize the output..|INPUT<br>VOLTAGE<br>OUTPUT|
|**INTERVAL ON**<br>Interval<br>B|Upon application of input voltage, the output is ener-<br>gized and the time delay (t) begins. At the end of the<br>time delay (t), the output is de-energized. Input voltage<br>must be removed to reset the time delay relay.|INPUT<br>VOLTAGE<br>OUTPUT|
|**OFF DELAY**<br>Delay on<br>Release<br>Delay on Break<br>Delay on<br>De-Energization|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the output is energized. Upon removal of the trigger, the<br>time delay (t) begins. At the end of the time delay (t),<br>the output is de-energized. Any application of the trigger<br>during the time delay will reset the time delay (t) and the<br>output remains energized.|INPUT<br>VOLTAGE<br>TRIGGER<br>—|<br>rs<br>ee ee<br>ourur | fpt|[itt|
|**SINGLE SHOT**<br>One Shot<br>Momentary<br>Interval|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the output is energized and the time delay (t) begins.<br>During the time delay (t), the trigger is ignored. At the<br>end of the time delay (t), the output is de-energized and<br>the time delay relay is ready to accept another trigger.|INPUT<br>VOLTAGE<br>TRIGGER<br>OUTPUT|
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
24
## **DEFINITION OF TIMING FUNCTIONS**
|**Function/Code**|**Operation**|**Timing Chart**|
|---|---|---|
|**FLASHER**<br>(Off First)|Upon application of input voltage, the time delay (t)<br>begins. At the end of the time delay (t), the output is<br>energized and remains in that condition for the time<br>delay (t). At the end of the time delay (t), the output<br>is de-energized and the sequence repeats until input<br>voltage is removed.|INPUT<br>VOLTAGE|
|**FLASHER**<br>(ON First)|Upon application of input voltage, the output is energized<br>and the time delay (t) begins. At the end of the time<br>delay (t), the output is de-energized and remains in that<br>condition for the time delay (t). At the end of the time de-<br>lay (t), the output is energized and the sequence repeats<br>until input voltage is removed.|INPUT<br>VOLTAGE<br>output ft eet ie|
|**ON/OFF DELAY**|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the time delay (t1) begins. At the end of the time delay<br>(t1), the output is energized. When the trigger is re-<br>moved, the output contacts remain energized for the time<br>delay (t2). At the end of the time delay (t2), the output is<br>de-energized & the time delay relay is ready to accept<br>another trigger. If the trigger is removed during time<br>delay period (t1), the output will remain de-energized and<br>time delay (t1) will reset. If the trigger is removed during<br>time delay period (t2), the output will remain energized<br>and the time delay (t2) will reset.|INPUT<br>VOLTAGE<br>TRIGGER<br>ss|
|**SINGLE SHOT**<br>**FALLING EDGE**|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the output remains de-energized. Upon removal of the<br>trigger, the output is energized and the time delay (t)<br>begins. At the end of the time delay (t), the output is<br>de-energized unless the trigger is removed and re-ap-<br>plied prior to time out (before time delay (t) elapses).<br>Continuous cycling of the trigger at a rate faster than the<br>time delay (t) will cause the output to remain energized<br>indefi nitely.|INPUT<br>VOLTAGE<br>TRIGGER<br>Es<br>—|
|**WATCHDOG**<br>**Retriggerable**<br>**Single Shot**|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the output is energized and the time delay (t) begins. At<br>the end of the time delay (t), the output is de-energized<br>unless the trigger is removed and re-applied prior to time<br>out (before time delay (t) elapses). Continuous cycling<br>of the trigger at a rate faster than the time delay (t) will<br>cause the output to remain energized indefi nitely.|INPUT<br>VOLTAGE<br>TRIGGER<br>||
|**TRIGGERED**<br>**ON DELAY**|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the time delay (t) begins. At the end of the time delay (t),<br>the output is energized and remains in that condition as<br>long as either the trigger is applied or the input voltage<br>remains. If the trigger is removed during the time delay<br>(t), the output remains de-energized & the time delay (t)<br>is reset.|INPUT<br>VOLTAGE<br>TRIGGER<br>||
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
25
## **DEFINITION OF TIMING FUNCTIONS**
|**Function/Code**|**Operation**|**Timing Chart**|
|---|---|---|
|**REPEAT CYCLE**<br>**(OFF 1st)**|Upon application of input voltage, the time delay (t1)<br>begins. At the end of the time delay (t1), the output is<br>energized and remains in that condition for the time<br>delay (t2). At the end of this time delay, the output is<br>de-energized and the sequence repeats until input volt-<br>age is removed.|INPUT<br>VOLTAGE<br>||<br>7|
|**REPEAT CYCLE**<br>**(ON 1st)**|Upon application of input voltage, the output is energized<br>and the time delay (t1) begins. At the end of the time<br>delay (t1), the output is de-energized and remains in that<br>condition for the time delay (t2). At the end of this time<br>delay, the output is energized and the sequence repeats<br>until input voltage is removed.|INPUT<br>VOLTAGE<br>|<br>|<br>| ||
|**DELAYED**<br>**INTERVAL**<br>**Single Cycle**|Upon application of input voltage, the time delay (t1)<br>begins. At the end of the time delay (t1), the output is<br>energized and remains in that condition for the time<br>delay (t2). At the end of this time delay (t2), the output<br>is de-energized. Input voltage must be removed to reset<br>the time delay relay.|INPUT<br>VOLTAGE<br>| |<br>=)|
|**TRIGGERED**<br>**DELAYED**<br>**INTERVAL**|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the time delay (t1) begins. At the end of the time delay<br>(t1), the output is energized and remains in that condition<br>for the time delay (t2). At the end of the time delay (t2),<br>the output is de-energized & the relay is ready to accept<br>another trigger. During both time delay (t1) & time delay<br>(t2), the trigger is ignored.|INPUT<br>VOLTAGE<br>TRIGGER<br>{<br>ee|<br>oureur | |ti[ @2 | (tif 2”|
|**TRUE OFF**<br>**DELAY**<br>a|Upon application of input voltage, the output is ener-<br>gized. When the input voltage is removed, the time<br>delay (t) begins. At the end of the time delay (t), the<br>output is de-energized. Input voltage must be applied<br>for a minimum of 0.5 seconds to assure proper opera-<br>tion. Any application of the input voltage during the time<br>delay (t) will reset the time delay. No external trigger is<br>required.<br>a|INPUT = —<br>VOLTAGE<br>—|
|**ON DELAY/**<br>**TRUE OFF**<br>**DELAY**|Upon application of input voltage, the time delay (t1)<br>begins. At the end of the time delay (t1), the output is<br>energized. When the input voltage is removed, the out-<br>put remains energized for the time delay (t2). At the end<br>of the time delay (t2), the output is de-energized. Input<br>voltage must be applied for a minimum of 0.5 seconds<br>to assure proper operation. Any application of the input<br>voltage during the time delay (t2) will keep the output<br>energized & reset the time delay (t2). No external trigger<br>is required.|INPUT<br>VOLTAGE<br>|)<br>| | |<br>ourput<br>ea| t1ay|
|**SINGLE**<br>**SHOT-FLASHER**|Upon application of input voltage, the time delay relay<br>is ready to accept a trigger. When the trigger is applied,<br>the time delay (t1) begins and the output is energized for<br>the time delay (t2). At the end of this time delay (t2), the<br>output is de-energized and remains in that condition for<br>the time delay (t2). At the end of the time delay (t2), the<br>output is energized and the sequence repeats until time<br>delay (t1) is completed. During the time delay (t1), the<br>trigger is ignored.|INPUT<br>VOLTAGE<br>a<br>a |<br>||
|**ON DELAY-**<br>**FLASHER**|Upon application of input voltage, the time delay begins<br>(t1). At the end of the time delay (t1), the output is<br>energized and remains in that condition for the time<br>delay (t2). At the end of this time delay (t2), the output is<br>de-energized and remains in that condition for the time<br>delay (t2). At the end of the time delay (t2), the output is<br>energized and the sequence repeats until input voltage<br>is removed.|INPUT<br>VOLTAGE<br>| |<br>**|**<br>OUTPUT<br>| t2 |<br>| t2 |<t2|
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
26
## **SOCKETS & ACCESSORIES**
|**8 Pin Octal Socket-**||**Catalog Number 70169-D**|
|---|---|---|
|**Surface or DIN Rail-Mounted**|||
|10A @ 600V<br>1 or 2 #12-22 AWG Wire<br>Recommended Tightening Torque|||
|of 7 in-lbs. (12 in-lbs maximum)<br>Pressure Wire Clamp Terminations||NY<br>Wy,|
|File #E169693 File #LR701114<br>.<br>.|||
||||
|**11 Pin Octal Socket-**<br>**Surface or DIN Rail-Mounted**<br>10A @ 300V<br>1 or 2 #12-22 AWG Wire||**Catalog Number 70170-D**|
|Recommended Tightening Torque|||
|of 7 in-lbs. (12 in-lbs maximum)<br>Pressure Wire Clamp Terminations<br>**8 Pin Octal Socket-**<br>**Back-Mounted**<br>10A @ 300V<br>Pressure Wire Clamp Terminations<br>**11 Pin Octal Socket-**<br>**Back-Mounted**<br>10A @ 300V<br>Pressure Wire Clamp Terminations<br>File #E169693 File #LR701114<br>File #E62437<br>File #E62437<br>2||**Catalog Number SR6P-M08G**<br>**Catalog Number SR6P-M11G**<br>1<br>a,<br>“<br>=<br>|aa<br>geee<br>te<br>i<br>Nis<br>MS<br>ig<br>§<br>sor MIR<br>Se<br>.<br>1<br>ens|
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
44
## **SOCKETS & ACCESSORIES**
## **Hold Down Spring Catalog Number 70166**
Can be used for:
- Panel-Mounted Sockets
- Sockets Mounted to 35mm DIN Rail *
- Requires two machine screws with washers & nuts-contact Macromatic or www.macromatic.com/70166 for
- more information.
## **DIN Rail Adaptor Kit Catalog Number 70500**
Quick & Economical Way to Install Any THx Series 2” x
- 2” Encapsulated Time Delay Relays on 35mm DIN Rail
- Clip Comes with a Threaded Hole to Eliminate Need for a Washer & Nut
- All Mounting Hardware Included
**800.238.7474 | www.macromatic.com | sales@macromatic.com**
45
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →