TPP 100-148A-J
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 100 W, 85V AC to 264V AC
- Manufacturer: TRACO POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):100W; Power Rating (Forced Cooling):-; Input Voltage VAC:85V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed; Output Vo
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TPP 100A-J Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 2.09A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 100W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 54.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TPP 100A-J Series, 100 Watt** ## **AC/DC Medical Power Supply** - **Open frame 100 W power supply with JST connection in 2.0” x 3.0” package** - **Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP** - **Low leakage current <75 µA rated for BF applications** - **Risk management process according to ISO 14971 incl. risk management file** - **Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3** - **Active power factor correction >0.95** - **Protection class l and ll prepared** - **Operating up to 5000 m altitude** - **Ready to meet ErP directive, <0.3 W no load power consumption** - **5-year product warranty** ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 The TPP 100A-J series of 100 Watt AC/DC open frame power supplies feature a reinforced double I/O isolation system according to latest medical safety standards (60601-1 3rd edition, 2 x MOPP). The earth leakage current is below 75 µA which makes the units suitable for BF (body floating) applications. The excellent efficiency of up to 92% allows a high power density for the standard 2.0” x 3.0” packaging format. The full load operating temperature range is –25°C to +55°C while it goes up to 80°C with 50% load derating. The EMC characteristic is dedicated for applications in industrial and medical fields. High reliability is provided by the use of industrial quality grade components and an excellent thermal management. It makes the products an ideal solution for medical devices and for demanding safety and space critical applications. ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TPP 100-112A-J**<br>**TPP 100-115A-J**<br>**TPP 100-124A-J**<br>**TPP 100-128A-J**<br>**TPP 100-136A-J**<br>**TPP 100-148A-J**|100 W|12 VDC(10.8 - 13.2 VDC)<br>15 VDC(13.5 - 16.5 VDC)<br>24 VDC(21.6 - 26.4 VDC)<br>28 VDC(25.2 - 30.8 VDC)<br>36 VDC(32.4 - 39.6 VDC)<br>48 VDC(43.2 - 52.8 VDC)|8'340 mA<br>6'670 mA<br>4'170 mA<br>3'580 mA<br>2'780 mA<br>2'090 mA|91 %<br>92 %<br>92 %<br>92 %<br>91 %<br>91 %| ## **Options** **on demand** (backorder with MOQ - Optional model with 18 VDC / 5'560 mA non stocking item) **Page 1 / 5** **March 16, 2023** **www.tracopower.com** **TPP 100A-J Series, 100 Watt** ## **Input Specifications** |Input Voltage|- AC Range| |---|---| ||- DC Range| |Input Frequency|| |Input Current|- Full Load & Vin = 230 VAC| ||- Full Load & Vin = 115 VAC| |Power Consumption|- No load & Vin = 230 VAC| ||- No load & Vin = 115 VAC| |Input Inrush Current|- At 230 VAC| ||- At 115 VAC| |Power Factor|- At 230 VAC| ||- At 115 VAC| |Input Protection|| |Recommended Input Fuse|| Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: +DC: L / –DC: N Operational Range: 47 - 440 Hz Certified: 50/60 Hz 550 mA max. 1'150 mA max. 300 mW max. (Ready to meet ErP directive) 300 mW max. 60 A max. 35 A max. 0.95 min. (Active Power Factor Correction) 0.95 min. (Active Power Factor Correction) T 3.15 A / 250 VAC (Internal Fuse in L & N) (The need of an external fuse has to be assessed in the final application.) ## **Output Specifications** Output Voltage Adjustment |Output Voltage Adjustment||±10%(By trim potentiometer)| |---|---|---| |||Output power must not exceed rated power!| |Voltage Set Accuracy||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)|0.2% max.| ||- Load Variation(0 - 100%)|0.5% max.| |Ripple and Noise||12 VDC model: 120 mVp-p typ.(w/ 10 µF X7R)| |(20 MHz Bandwidth)||15 VDC model: 150 mVp-p typ.(w/ 10 µF X7R)| |||18 VDC model: 160 mVp-p typ.(w/ 10 µF X7R)| |||24 VDC model: 160 mVp-p typ.(w/ 1 µF X7R)| |||28 VDC model: 180 mVp-p typ.(w/ 1 µF X7R)| |||36 VDC model: 190 mVp-p typ.(w/ 1 µF X7R)| |||48 VDC model: 340 mVp-ptyp. (w/ 0.1µF X7R)| |Capacitive Load||12 VDC model: 6'950 µF max.| |||15 VDC model: 4'450 µF max.| |||18 VDC model: 3'100 µF max.| |||24 VDC model: 1'750 µF max.| |||28 VDC model: 1'280 µF max.| |||36 VDC model: 770 µF max.| |||48 VDC model: 430µF max.| |Minimum Load||Not required| |Temperature Coefficient||±0.02 %/K max.| |Hold-up Time|- At 230 VAC|16 ms min.| ||- At 115 VAC|16 ms min.| |Start-up Time|- At 230 VAC|1'000 ms max.| ||- At 115 VAC|1'000 ms max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||115 - 150% of Iout max.| |Overvoltage Protection||115 - 135% of Vout nom.| |Transient Response|- Response Deviation|3% max.(50% to 75% Load Step)| ||- Response Time|500 µs typ.(50% to 75% Load Step)| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 5** **March 16, 2023** **www.tracopower.com** **TPP 100A-J Series, 100 Watt** ## **Safety Specifications** Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/overview/tpp100a-j Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II ## **EMC Specifications** |EMI Emissions||EN 60601-1-2 edition 4(Medical Devices)| |---|---|---| ||- Conducted Emissions|EN 55011 class B(internal filter)| |||EN 55032 class B(internal filter)| |||FCC Part 15 class B(internal filter)| |||FCC Part 18 class B(internal filter)| ||- Radiated Emissions|EN 55011 class A(internal filter)| |||EN 55032 class A(internal filter)| |||FCC Part 15 class A(internal filter)| |||FCC Part 18 class A(internal filter)| ||- Harmonic Current Emissions|EN 61000-3-2, class A| |||EN 61000-3-2, class D| ||- Voltage Fluctuations & Flicker|EN 61000-3-3| |EMS Immunity||EN 55024(IT Equipment)| |||EN 55035(Multimedia)| |||EN 60601-1-2 edition 4(Medical Devices)| ||- Electrostatic Discharge|Air: EN 61000-4-2, ±15 kV, perf. criteria A| |||Contact: EN 61000-4-2, ±8 kV, perf. criteria A| ||- RF Electromagnetic Field|EN 61000-4-3, 20 V/m, perf. criteria A| ||- EFT (Burst) / Surge|EN 61000-4-4, ±2 kV, perf. criteria A| |||L to L: EN 61000-4-5, ±1 kV, perf. criteria A| |||L to PE: EN 61000-4-5, ±2 kV, perf. criteria A| ||- Conducted RF Disturbances|EN 61000-4-6, 20 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous: EN 61000-4-8, 10 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz: EN 61000-4-11| |||30%, 25 periods, perf. criteria A| |||>95%, 0.5 periods, perf. criteria A| |||>95%, 1 period, perf. criteria A| |||>95%, 250 periods, perf. criteria B| |||115 VAC / 60 Hz: EN 61000-4-11| |||30%, 25 periods, perf. criteria A| |||>95%, 0.5 periods, perf. criteria A| |||>95%, 1 period, perf. criteria A| |||>95%,250periods, perf. criteria B| ## **General Specifications** |Relative Humidity||95% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|–25°C to +85°C| ||- Storage Temperature|–40°C to +85°C| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 5** **March 16, 2023** **www.tracopower.com** **TPP 100A-J Series, 100 Watt** |Power Derating|- High Temperature|2 %/K above 55°C| |---|---|---| ||- Low Input Voltage|1.33 %/V below 100 VAC| |||See application note: www.tracopower.com/overview/tpp100a-j| |CoolingSystem||Natural convection(20 LFM)| |Altitude DuringOperation||5'000 m max.| |SwitchingFrequency||45 - 75 kHz (PWM QR)| |Insulation System||Reinforced Insulation| |WorkingVoltage (rated)||250 VAC| |Isolation Test Voltage|- Input to Output, 60 s|4'000 VAC| ||- Input to Case or PE, 60 s|1'500 VAC| ||- Output to Case or PE,60 s|1'500 VAC| |Isolation Resistance|- Input to Output,500 VDC|100 MΩ min.| |Leakage Current|- Touch Current|75 µA max.| |(at 264 VAC)||| |Reliability|- Calculated MTBF|790'000 h(MIL-HDBK-217F, ground benign)| |Environment|- Vibration|IEC 60068-2-6| |||5 g, 3 axis, sine sweep, 5-500 Hz, 1 oct/min| ||- Mechanical Shock|IEC 60068-2-27| |||50g,3 axis,half sine,11 ms| |HousingType||Open Frame| |MountingType||Chassis Mount| |Connection Type||Pin Connector| |Weight||156 g| |Environmental Compliance|- REACH Declaration|www.tracopower.com/info/reach-declaration.pdf| |||REACH SVHC list compliant| |||REACH Annex XVII compliant| ||- RoHS Declaration|www.tracopower.com/info/rohs-declaration.pdf| |||Exemptions: 7a, 7c-I| |||(RoHS exemptions refer to the component| |||concentration only, not to the overall| |||concentration in the product (O5A rule).| |||The SCIP number isprovided on request.)| |**Supporting Documents**|| |---|---| |Overview Link(for additional Documents)|www.tracopower.com/overview/tpp100a-j| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 4 / 5** **March 16, 2023** **www.tracopower.com** **TPP 100A-J Series, 100 Watt** ## **Outline Dimensions** **==> picture [284 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> 76.2 (3.00)<br>69.8 (2.748)<br>1<br>3<br>4<br>1<br>Voltage adjustment<br>TOP VIEW<br>Dimension in mm, () = inch<br>Tolerances: x.x ±0.50 (±0.02)<br> x.xx ±0.25 (±0.01)<br>2.5 (0.10) max.<br>FRONT VIEW<br>Ø 3.2 (0.13)<br>50.8 (2.00) CON1<br>CON2 44.45 (1.750)<br>1.6 (0.06)<br>29.5 (1.16)<br>**----- End of picture text -----**<br> ## Pin connectors |Pin connectors|Pin connectors|Pin connectors|Pin connectors| |---|---|---|---| |Input(CON1)||Output(CON2)|| |Pin|Function|Pin*|Function| |1|Line|1,2|–Vout| |3|Neutral|3,4|+Vout| *Terminal rated for 7 A max. (at higher current connection has to be split) CON1: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-3N CON2: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-4N © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. Rev. March 16, 2023 **Page 5 / 5** www.tracopower.com
Updated at April 27, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →