TMG 50124
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 50 W, 24 VDC, 2.083 A
- Manufacturer: TRACO POWER
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:50W; Output Voltage - Output 1:24V; Output Current - Output 1:2.083A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (16-Jul-2019)
- Depth: 74.1mm
- Width: 54.1mm
- Height: 21.8mm
- Product Range: TMG 50 Series
- No. of Outputs: 1 Output
- Output Power Max: 50W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.083A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 50.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Power Supply** **TMG 50 Series, 50 Watt** - **Fully encapsulated power supplies in plastic casing for PCB mount** - **Fully regulated outputs** - **3000 VAC I/O-isolation** - **High efficiency up to 90%** - **Universal input range 90 to 264 VAC** - **Operating temperature range: –40°C to +70°C max.** - **Safety class II prepared** - **Short circuit over power and over voltage limitation** UL 62368-1 IEC 62368-1 TMG 50 Series AC/DC power modules come in fully encapsulated plastic package. They are ultra-compact, energy-efficient and cost/performance optimised for prevailing market requirements. The high efficiency and the use of high grade components make these modules suitable for an operating temperature range of –40°C to +70°C. The modules are protected against short-circuit and over voltage. EMI/EMC characteristics and the safety approval package qualify them for demanding applications in equipment for industrial or commercial environments. ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TMG 50105**<br>**TMG 50112**<br>**TMG 50115**<br>**TMG 50124**<br>**TMG 50148**|40 W|5 VDC<br>12 VDC<br>15 VDC<br>24 VDC<br>48 VDC|8'000 mA<br>4'167 mA<br>3'333 mA<br>2'083 mA<br>1'040 mA|86 %<br>90 %<br>87 %<br>88 %<br>89 %| ||50 W|||| **Page 1 / 4** **March 16, 2023** **www.tracopower.com** **TMG 50 Series, 50 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range: 90 - 264 VAC(Full Range)| |---|---|---| |||Rated Range: 100 - 240 VAC(Full Range)| ||- DC Range|Operational Range: 120 - 370 VDC(Designed for, no certification)| |||Polarity: irrelevant| |Input Frequency||Operational Range: 47 - 440 Hz| |||Certified: 50/60 Hz| |Input Current|- Full Load & Vin = 230 VAC|600 mA max.| ||- Full Load & Vin = 115 VAC|1'000 mA max.| |Power Consumption|- No load & Vin = 230 VAC|1'000 mW max.| ||- No load & Vin = 115 VAC|1'000 mW max.| |Input Inrush Current|- At 230 VAC|60 A max.| ||- At 115 VAC|40 A max.| |||(For the 7 & 15 W models an external Thermistor| |||has to be integreated in the circuit at the| |||converter input L in series.| |||Thermistor recommendation: 10R / 15z)| |Recommended Input Fuse||3'150 mA(slow blow)| |||(The need of an external fuse has to be assessed| |||in the final application.)| ## **Output Specifications** |Voltage Set Accuracy||±2% max.| |---|---|---| |Regulation|- Input Variation (Vmin - Vmax)|1% max.| ||- Load Variation(0 - 100%)|1% max.| |Ripple and Noise||5 VDC model: 120 mVp-p max.(w/ 0.1 µF || 47 µF)| |(20 MHz Bandwidth)||12 VDC model: 120 mVp-p max.(w/ 0.1 µF || 47 µF)| |||15 VDC model: 150 mVp-p max.(w/ 0.1 µF || 47 µF)| |||24 VDC model: 240 mVp-p max.(w/ 0.1 µF || 47 µF)| |||48 VDC model: 480 mVp-pmax. (w/ 0.1µF||47µF)| |Capacitive Load||5 VDC model: 10'000 µF max.| |||12 VDC model: 3'500 µF max.| |||15 VDC model: 3'000 µF max.| |||24 VDC model: 2'200 µF max.| |||48 VDC model: 330µF max.| |Minimum Load||Not required| |Temperature Coefficient||±0.02 %/K max.| |Hold-up Time|- At 230 VAC|50 ms min.| ||- At 115 VAC|10 ms min.| |Start-up Time|- At 230 VAC|250 ms max.| ||- At 115 VAC|400 ms max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||200 - 258% of Iout max.| |Overvoltage Protection||105 - 145% of Vout nom.| |||(By Zener diode)| |Transient Response|- Response Deviation|2% max.(75% to 100% Load Step)| ||- Response Time|500 µs typ.(75% to 100% Load Step)| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 4** **March 16, 2023** **www.tracopower.com** **TMG 50 Series, 50 Watt** ## **Safety Specifications** Safety Standards - IT / Multimedia Equipment - Certification Documents Protection Class Pollution Degree Over Voltage Category **EMC Specifications** EMI Emissions - Conducted Emissions - Radiated Emissions EMS Immunity - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge - Conducted RF Disturbances - PF Magnetic Field - Voltage Dips & Interruptions EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/tmg50 Class I & II (Prepared): Reinforced Insulation PD 2 OVC II EN 55032 class B (internal filter) EN 55032 class B (internal filter) EN 55024 (IT Equipment) EN 55035 (Multimedia) Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A Ext. input component: Use an external Varistor at the converter input (in parallel). Recommendation: 14S471K EN 61000-4-6, 10 Vrms, perf. criteria A Continuous: EN 61000-4-8, 30 A/m, perf. criteria A 230 VAC / 50 Hz: 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A 115 VAC / 60 Hz: 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A ## **General Specifications** |Relative Humidity||95% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|–40°C to +70°C| ||- Storage Temperature|–40°C to +85°C| |Power Derating|- High Temperature|3.75 %/K above 50°C| ||- Low Input Voltage|2 %/V below 100 VAC| |||See application note: www.tracopower.com/overview/tmg50| |CoolingSystem||Natural convection(20 LFM)| |Altitude DuringOperation||2'000 m max.| |SwitchingFrequency||60 - 70 kHz (PWM)| |Insulation System||Reinforced Insulation| |WorkingVoltage (rated)||310 VAC| |Isolation Test Voltage|- Input to Output,60 s|3'000 VAC| |Creepage|- Input to Output|4.8 mm min.| |Clearance|- Input to Output|4 mm min.| |Leakage Current|- Earth Leakage Current|250 µA max.| |(at 240 VAC)||| |Reliability|- Calculated MTBF|300'000 h(MIL-HDBK-217F, ground benign)| |WashingProcess||Not allowed| |HousingMaterial||Plastic resin(UL 94 V-0 rated)| |Potting Material||Silicone(UL 94 V-0 rated) (Hermetical sealed| |||structure,dust-proof onlynon water-proof)| |Pin Material||Brass| |Pin Surface Plating||Tin(120µm min.),matte| |HousingType||Plastic Case| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 4** **March 16, 2023** **www.tracopower.com** **TMG 50 Series, 50 Watt** Mounting Type Connection Type Weight Environmental Compliance - REACH Declaration - RoHS Declaration PCB Mount THD (Through-Hole Device) 166 g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/tmg50 ## **Outline Dimensions** **==> picture [429 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> 74.1<br>Pinout<br>62.0 21.8 8.0<br>Pin Function<br>1 AC IN (N)<br>2 AC IN (L)<br>3 3 –Vout<br>Ø 1.0 4 +Vout<br>1 top view<br>4<br>2<br>6.05 Dimensions in mm<br>Tolerances ±0.5 mm<br>Pin tolerances ±0.1 mm<br>15.55<br>27.05<br>54.1 23.0<br>20.0<br>15.55<br>.05<br>7<br>**----- End of picture text -----**<br> © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. Rev. March 16, 2023 **Page 4 / 4** www.tracopower.com
Updated at June 3, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →