- Manufacturer: CUI
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: Lead (21-Jan-2025)
- Product Range: TJ-100 Series
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 124.88 € |
| Current stock | 10+ |
| Lead time | 30 days |
**date** 09/05/2024 **page** 1 of 6 ## **SERIES:** TJ-100 **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - 100 W continuous output power - universal input (90~264 Vac, 120~370 Vdc) - -40 ~ 85 °C operating range with derating - extended peak power rating - optional heatsink or baseplate cooling - output short circuit/over voltage/current protection/temperature - input under voltage protection - 17 mm low profile PCB through-hole package - UL/EN/IEC 62368-1 certified - CISPR32/EN55032 Class B |**MODEL**|**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power1**|**ripple**<br>**and noise2**|**efficiency3**| |---|---|---|---|---|---| |||**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|(%)| |TJ-100-12|12|8.4|100|120|93.5| |TJ-100-24|24|4.2|100|150|94.5| |TJ-100-28|28|3.6|100|240|94.5| |TJ-100-36|36|2.8|100|280|94.5| |TJ-100-48|48|2.1|100|300|94.5| ## **MODEL** Notes: 1. Ripple & noise are measured at 20 MHz BW with 0.1 μF ceramic capacitor and a 10 μF electrolytic capacitors. 2. At 230 Vac, full load, 25°C. ## **PART NUMBER KEY** ## **- - TJ 100 XX** Base Number Output Voltage **cui** .com Please read our datasheet & drawing disclaimer here. **CUI Inc │ SERIES:** TJ-100 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/05/2024 **│ page** 2 of 6 |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage||90<br>120||264<br>370|Vac<br>Vdc| |frequency||47||63|Hz| |input current|at 100 Vac, full load|||1.5|A| |inrush current|at 240 Vac, cold start||8.5||A| |leakage current|earth<br>touch|||0.25<br>0.1|mA<br>mA| |power factor|at 230 Vac /50 Hz, full load|0.91|||| |under voltage protection||55|65|75|Vac| |no load power consumption||||0.5|W| |**OUTPUT**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||at 115 Vac and 230 Vac input, full load, 25 °C||||| ||12 Vdc output model|||8,400|μF| |capacitive load|24 Vdc output model<br>28 Vdc output model|||4,200<br>3,600|μF<br>μF| ||38 Vdc output model|||2,800|μF| ||48 Vdc output model|||2,100|μF| |line regulation|high line to low line|||±0.5|%| |load regulation|10% load to full load|||±0.5|%| |initial set point accuracy|at full load||±1||%| ||at 90 Vac ~ 264 Vac input, full load, 25 °C||||| ||12 Vdc output model|11.88|12|12.12|Vdc| |initial set point|24 Vdc output model<br>28 Vdc output model|23.76<br>27.72|24<br>28|24.24<br>28.28|Vdc<br>Vdc| ||38 Vdc output model|35.64|36|36.36|Vdc| ||48 Vdc output model|47.52|48|48.48|Vdc| ||at 90 Vac ~ 264 Vac input, see derating curve||||| ||12 Vdc output model|||8.4|A| |operating current range|24 Vdc output model<br>28 Vdc output model|||4.2<br>3.6|A<br>A| ||38 Vdc output model|||2.8|A| ||48 Vdc output model|||2.1|A| ||at 115 Vac, full load||||| |hold-up time|28 Vdc output model|20|30||ms| ||all other output models|30|40||ms| |start-up delay|at 90 Vac ~ 264 Vac input||1||s| |switching frequency|||110||kHz| |temperature coefcient||||±0.02|%/°C| |peak power3|less than 5 seconds duration, 10% maximum duty|cycle|120||%| Notes: 3. If 120% of max power is supplied for 5 seconds, then at least 45 seconds of 75% of max power or less must be supplied. ## **PROTECTIONS** |**PROTECTIONS**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||latch of, auto recovery||||| ||12 Vdc output model|||16|Vdc| |over voltage protection|24 & 28 Vdc output model|||35|Vdc| ||38 Vdc output model|||50|Vdc| ||48 Vdc output model|||63|Vdc| |over current protection|hiccup, auto recovery|120|135|150|%| |short circuit protection|auto recovery||||| |over temperature protection|auto recovery||||| **cui** .com **CUI Inc │ SERIES:** TJ-100 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/05/2024 **│ page** 3 of 6 ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**<br>**min**<br>**typ**|**max**|**units**| |---|---|---|---| ||input to output for 1 minute|4,000|Vac| |isolation voltage|input to ground for 1 minute|1,800|Vac| ||output to ground for 1 minute|1,800|Vac| |safety approvals4|certified to 62368-1: IEC, EN, UL||| ||EN 55032: 2015+A11: 2020, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B||| |EMI/EMC|EN 61000-6-4: 2019, 47 CFR FCC Part 15 Subpart B, EN 61204-3: 2018,||| ||EN 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019||| |conducted emissions|EN 55032: 2015+A11: 2020, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B<br>EN 61000-6-4: 2019, 47 CFR FCC Part 15 Subpart B, EN 61204-3: 2018||| |radiated emissions|EN 55032: 2015+A11: 2020, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B<br>EN 61000-6-4: 2019, 47 CFR FCC Part 15 Subpart B, EN 61204-3: 2018||| |ESD|IEC 61000-4-2: 2008, Air Discharge: ±8KV, Contact Discharge: ±4KV, perf. Criteria A||| |radiated immunity|IEC 61000-4-3: 2020, perf. Criteria A||| |EFT/Burst|IEC 61000-4-4: 2012, ±1kV, ±2kV, perf. Criteria A||| |surge|IEC 61000-4-5: 2014+A1: 2017, L-N: ±0.5kV, ±1kV, L-E(ground): ±0.5kV, ±1kv, ±2kV, perf. Criteria A|IEC 61000-4-5: 2014+A1: 2017, L-N: ±0.5kV, ±1kV, L-E(ground): ±0.5kV, ±1kv, ±2kV, perf. Criteria A|| |conducted immunity|IEC 61000-4-6: 2013+COR1: 2015, perf. Criteria A||| |class|class I||| |MTBF|as per MIL-HDBK-217F at 25 °C, full load<br>600,000||hours| |Notes:<br>4. 62368 certification applies only when ac input is applied.|||| ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curves|-40||85|°C| |operating case temperature|at the centre of base plate|-40||90|°C| |storage temperature||-40||100|°C| |operating humidity|non-condensing|-||93|%| |operating altitude||||5,000|m| |shock|10 ms along each of the X, Y, and Z axes 3 times||75||g| |vibration|15 ~ 2,000Hz for 1 hour along each of the X, Y, and Z axes||4||g| ## **DERATING CURVES** **cui** .com **CUI Inc │ SERIES:** TJ-100 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/05/2024 **│ page** 4 of 6 ## **EFFICIENCY CURVES** **cui** .com **CUI Inc │ SERIES:** TJ-100 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/05/2024 **│ page** 5 of 6 ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|4.60 x 2.40 x 0.67 [116.8 x 61.0 x 17.0 mm]||||inch| |weight|||240||g| ## **MECHANICAL DRAWING** units: inch [mm] tolerance: inches: x.xx = ±0.03, x.xxx = ±0.020 mm: x.x = ±0.7, x.xx = ±0.50 |PIN CONNECTIONS|PIN CONNECTIONS| |---|---| |1|AC(L)| |2|AC(N)| |3|GND| |4|+Vout| |5|-Vout| Note: The thermal plate and mounting holes are electrically connected to the GND pin. **cui** .com **CUI Inc │ SERIES:** TJ-100 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/05/2024 **│ page** 6 of 6 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|09/05/2024| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [119 x 38] intentionally omitted <==** **Headquarters** 15575 SW Sequoia Pkwy #100 Portland, OR 97224 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →