- Manufacturer: RED LION CONTROLS
- Product type: Controller Accessories
- Current Rating: 100mA
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 43.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
Bulletin No. VCM-A Drawing No. LP0646 Released 02/10
Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net
## _**CONVERTER MODULES**_
## _**ADAPTS MANY RED LION CONTROLS’ COUNTERS AND ACCESSORIES TO A WIDE RANGE OF SIGNAL SOURCES**_
## _VCM - VOLTAGE CONVERTER MODULES_
Converts AC/DC voltages to an acceptable signal input for many RLC counters and accessories and provides input/output voltage isolation.
## _TCM - TRIAC CONVERTER MODULE_
Accepts unloaded, high off-state leakage triac output from sensors and programmable controllers.
## _LCM - LOGIC CONVERTER MODULE_
Interfaces with CMOS, TTL, and other logic circuits up to +28 VDC, at speeds to 50 KHz. Allows Cub Counters to share sensor outputs with other series counters.
These miniature sized modules are completely encapsulated in PVC, which provides protection against oil, water, dirt, and mechanical damage. They can be quickly and easily mounted to most surfaces by using the self-stick adhesive pad.
## _**VCM - VOLTAGE CONVERTER MODULES**_
These modules provide a convenient way to adapt RLC Counters to most any machine control voltage signal. They also make it easy to upgrade electromechanical counter installations with RLC Counters.
VCM’s are available in two input voltage ranges that cover the spectrum from 4-270 V. The non-polarized input of these modules will accept A.C. _(50/60 Hz)_ or D.C. voltages at input cycles up to 30 Hz. The output uses MOSFET technology that is compatible with either the L.S. Count or Remote Reset inputs of RLC Counters. Electrical isolation between input and output is achieved by means of an internal opto-isolator rated at 2300 VRMS.
## _**SPECIFICATIONS**_
1. **INPUT:** VCM1 = 4 to 50 VAC/DC, 50/60 Hz VCM2 = 50 to 270 VAC/DC, 50/60 Hz
2. **OUTPUT:** Solid state DC contact closure Output rating: 30 VDC at 100 mA max Output Isolation: 2300 VRMS Off State Leakage: 1 A max
3. **FREQUENCY:** Max output frequency 20 Hz
4. **ENVIRONMENT:** 0-50 ºC
## _**DIMENSIONS FOR VCM, TCM, & LCM In inches (mm)**_
**==> picture [468 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
(SEE ORDERING INFORMATION<br>FOR WIRE COLOR)<br>1.12 (28.5)<br>™ ro<br>0.71<br>(18)<br>BLACK INPUT LEADS: 6"(150mm) Long, 22GA. VCM<br>1.52 (38.5) and TCM Leads have 600V Insulation. LCM has<br>OUTPUT LEADS: 6" (150mm) Long<br>22GA Stranded, 300V Insulation 3 Leads with 300V Insulation. (For color codes<br>see specific model.)<br>{<br>0.45<br>(11.5)<br>f : SELF STICK<br>ADHESIVE PAD<br>OUTPUT INPUT<br>**----- End of picture text -----**<br>
_**1**_
## _**TCM - TRIAC CONVERTER MODULE**_
The TCM is a specialized version of the VCM. It is specifically designed to operate with photo-electric sensors and programmable controllers that have 115 VAC Triac outputs. Due to protective suppression circuits connected in parallel with Triacs, these outputs have a high OFF-State Leakage current, which, if unloaded, is sufficient to keep a VCM in the ON condition continuously.
The TCM incorporates a current bias that offsets output leakage currents up to 4 mA and allows the application of RLC Counters to most unloaded Triac outputs. These modules are available for operation with 115 VAC ±10% 50/60 Hz only. They operate at count rates up to 10 cps, and also provide input/output electrical isolation. Connections for the TCM are the same as those for the VCM.
## _**SPECIFICATIONS**_
1. **INPUT:** 115 VAC 10% (50/60 Hz) 10 mA max current draw
2. **FREQUENCY:** 10 Hz max output
3. **OUTPUT:** Solid state DC contact closure Output rating: 30 VDC at 100 mA Output Isolation: 2300 VRMS Off State Leakage: 1 A max
4. **ENVIRONMENT:** 0-50 ºC
_Note: VCM’s can be used with Triac outputs that are also driving substantial loads, since the load will shunt the leakage current away from the VCM input._
## _**TYPICAL CONNECTION EXAMPLE FOR VCM & TCM (Shown with optional VCM for Control Voltage Remote Reset)**_
Consult Connections and Configurations set up information in counter instruction literature for wiring. Reference switch and contact input information.
**==> picture [513 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
EXISTING CONTACT<br>USED TO OPERATE<br>RELAY<br>RLC COUNTER SEE ORDERING INFORMATION<br>FOR WIRE COLOR<br>COUNTRESET COUNT ORANGE RELAYCOIL CONTROLMACHINEVOLTAGE<br>COMMON BLACK VCM/TCM ORANGE<br>RESET CONTACT<br>SEE ORDERING INFORMATION MACHINE<br>FOR WIRE COLOR ORANGE CONTROL<br>REMOTE VOLTAGE<br>RESET<br>BLACK VCM/TCM ORANGE<br>OUTPUT INPUT<br>OUTPUT INPUT<br>**----- End of picture text -----**<br>
## _**LCM - CONVERTER MODULE**_
The LCM adapts CUB* Counters to practically any type of logic and sensor output, and to any count signal voltage from +3 to +28 VDC. The module accepts input count pulses from NPN Open-Collector Transistor outputs, Bi-Polar outputs, or sourcing outputs such as Emitter-Follower or PNP OpenCollector Transistors _(Sourcing outputs must be externally loaded with a load of 10 Kohms or less)_ . The LCM output is a Bi-Polar drive that is compatible with either the Low-Speed or High-Speed Counter inputs as well as the Remote Reset input** of the CUB Counters. The output is inverted with respect to the input which causes the CUB Counter to increment on the leading _(positive going)_ edge of a count pulse. Power for operation of the LCM can be normally obtained from the existing D.C. power supply used to operate the sensor or other logic circuitry. When count pulse signals are generated by switch contacts the LCM output can be applied to the L.S. input of the CUB to de-bounce these pulses. Minimum pulse width when driving the L.S. input is 10 msec and maximum count rate is 50 cps.
- _LCM intended for use with CUB1,2,3,and 7._
- ** _When used to operate Remote Reset input, the LCM will reset counter when input to LCM goes high due to signal inversion._
## _**SPECIFICATIONS**_
1. **POWER:** 5 to 28 VDC, 8 mA max
2. **INPUT:** VIH = +2.5 to 28 VDC, 500 A max source VIL = +1.0 VDC, 50 A max sink
3. **OUTPUT:** Bipolar 3 VDC with 1 mA sink/source (output should not be connected to voltage levels above 3.5 VDC)
4. **FREQUENCY:** MAX input/output frequency = 50 KHz (see counter input for frequency limitations)
5. **ENVIRONMENT:** 0-50 ºC
**==> picture [256 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
ALTERNATE CONNECTION<br>FOR SWITCH CONTACT<br>INPUT (SEE TEXT) TO EXT. D.C.<br>SUPPLY +5 TO<br>28VDC, 8mA<br>CUB CONTROLLER<br>INPUT COUNT<br>H.S. CNT.L.S. CNT.REM. RST. WHITE BLUEOR PULSEV = 2.5 TO 28VDCV = +1.0VIHIL<br>RST. EN. BLK<br>COMMON BLACK COMMON<br>OUTPUT INPUT<br>**----- End of picture text -----**<br>
_**2**_
## _**TYPICAL INPUTS TO LCM**_
**==> picture [482 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
CMOS OR TTL NPN OPEN COLLECTOR PNP OPEN COLLECTOR<br>(SINK OUTPUT) (SOURCE OUTPUT)<br>5 TO 28VDC 5 TO 28VDC 5 TO 28VDC<br>SUPPLY SUPPLY SUPPLY<br>+ - + -<br>SENSOR SENSOR<br>OR LOGIC OR LOGIC<br>CIRCUIT CIRCUIT<br>LCM BLUE LCM BLUE LCM BLUE<br>ORANGE ORANGE ORANGE<br>BLACK BLACK BLACK<br>INPUT INPUT INPUT 10K<br>**----- End of picture text -----**<br>
## _**ORDERING INFORMATION**_
|**MODEL NO.**|**DESCRIPTION**|**INPUT VOLTAGE**|**OUTPUT WIRE**<br>**COLOR**|**PART NUMBER**|
|---|---|---|---|---|
|VCM|Voltage Converter Module|4 - 50 V AC/DC|yellow|VCM10000|
|||50 - 270 V AC/DC|white|VCM20000|
|TCM|Triac Converter Module|115 VAC ±10%|white/green trace|TCM10000|
|LCM|Logic Converter Module|+3 to +28 VDC (signal)<br>+5 to +28 VDC (supply)|white|LCM10000|
_**3**_
## **LIMITED WARRANTY**
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.
Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839
Red Lion Controls Europe Printerweg 10 NL - 3821 AD Amersfoort Tel +31 (0) 334 723 225 Fax +31 (0) 334 893 793
Red Lion Controls India 54, Vishvas Tenement GST Road, New Ranip, Ahmedabad-382480 Gujarat, India Tel +91 987 954 0503 Fax +91 79 275 31 350
Red Lion Controls China Unit 101, XinAn Plaza Building 13, No.99 Tianzhou Road ShangHai, P.R. China 200223 Tel +86 21 6113-3688 Fax +86 21 6113-3683
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →