TBLC 06-105
AC/DC DIN Rail Power Supply (PSU), ITE & Household, 1 Output, 6 W, 5 VDC, 1.2 A
- Manufacturer: TRACO POWER
- Product type:
- No. of Outputs:1 Output; Output Power Max:6W; Output Voltage - Output 1:5V; Output Current - Output 1:1.2A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TBLC Series
- No. of Outputs: 1 Output
- Output Power Max: 6W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 1.2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 25.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Industrial Power Supply** **TBLC 06 Series, 6 Watt** - **High power density in low profile case, module depth < 55 mm** - **Suitable for mounting in domestic installation panels** - **Very high efficiency and low standby power -> compliance to ECO-Standard** - **Low output ripples and spikes** - **Suitable for household appliance and industrial application** - **For distributed power** - **Operating temperature range: –25°C to +70°C** - **UL 508 listed** - **UL 1310 class II, NEC class 2 compliance** - **3-year product warranty** UL 508 UL 60950-1 IEC 60335-1 IEC 60950-1 This new DIN-Rail mounting power supplies are designed for industrial and residential applications. They are lower cost than the existing TBL range, with similar electrical specifications. Additionally, they fully comply to the new standby power and efficiency requirements (ECO Standard). They are intended for connecting as class II devices, so the safety earth connection is not required. They are mountable in flat racks due to their small dimensions in depth. Their dimensions comply to the DIN 43880 standard. |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TBLC 06-105**<br>**TBLC 06-112**<br>**TBLC 06-124**|6 W|5 VDC(5.0 - 5.5 VDC)<br>12 VDC(12.0 - 16.0 VDC)<br>24 VDC(24.0 - 28.0 VDC)|1'200 mA<br>500 mA<br>250 mA|74 %<br>81 %<br>79 %| **Page 1 / 4** **November 30, 2022** **www.tracopower.com** **TBLC 06 Series, 6 Watt** ## **Input Specifications** Input Voltage Input Frequency Power Consumption - No load & Vin = 230 VAC - No load & Vin = 115 VAC Input Inrush Current - At 230 VAC - At 115 VAC Recommended Input Fuse Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) Operational Range: 47 - 63 Hz Certified: 50/60 Hz 300 mW max. (Ready to meet ErP directive) 300 mW max. 30 A max. 15 A max. (The need of an external fuse has to be assessed in the final application.) ## **Output Specifications** Output Voltage Adjustment 5 VDC model: 5.0 - 5.5 VDC 12 VDC model: 12.0 - 16.0 VDC 24 VDC model: 24.0 - 28.0 VDC |||(By trim potentiometer)| |---|---|---| |||Outputpower must not exceed ratedpower!| |Voltage Set Accuracy||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)|0.3% max.| ||- Load Variation(10 - 90%)|0.3% max.| |Ripple and Noise||50 mVp-p max.| |(20 MHz Bandwidth)||| |Minimum Load||Not required| |Temperature Coefficient||±0.02 %/K max.| |Hold-up Time|- At 230 VAC|60 ms min.| ||- At 115 VAC|15 ms min.| |Start-up Time|- At 230 VAC|1'000 ms max.| ||- At 115 VAC|1'000 ms max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||105 - 130% of Iout max.| |Overvoltage Protection||125 - 150% of Vout nom.| |Transient Response|- Peak Variation|500 mV max.(10% to 90% Load Step)| ||- Response Time|4'000 µs typ.(10% to 90% Load Step)| ## **Safety Specifications** Safety Standards - IT / Multimedia Equipment - Industrial Control Equipment - Household - Machines Equipment - Power Installation - Measurement, Control & Lab. - Power Transformers - Converter System - Certification Documents Protection Class EN 60950-1 IEC 60950-1 UL 60950-1 UL 508 EN 60335-1 IEC 60335-1 EN 60204 EN 50178 EN 61010-1 EN 61010-2-201 IEC 61010-1 IEC 61010-2-201 EN 61558-2-8 EN 61558-2-16 EN 62477 IEC 62477 www.tracopower.com/overview/tblc06 Class I & II (Prepared): Reinforced Insulation All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 4** **November 30, 2022** **www.tracopower.com** **TBLC 06 Series, 6 Watt** |Class 2 Power Units|||UL 1310| |---|---|---|---| ||||NEC Class 2| |Pollution Degree|||PD 2| |Over Voltage Category|||OVC II| |**EMC Specifications**|||| |EMI Emissions|||EN 61000-6-3(Generic Residential)| ||||EN 61204-3(Low Voltage Power Supplies)| ||- Conducted Emissions||EN 55011 class B(internal filter)| ||||EN 55032 class B(internal filter)| ||- Radiated Emissions||EN 55011 class B(internal filter)| ||||EN 55032 class B(internal filter)| ||- Harmonic Current Emissions||EN 61000-3-2,class A| |EMS Immunity|||EN 61000-6-2(Generic Industrial)| ||||EN 61204-3(Low Voltage Power Supplies)| ||- Electrostatic Discharge|Air:|EN 61000-4-2, ±8 kV, perf. criteria B| |||Contact:|EN 61000-4-2, ±4 kV, perf. criteria B| ||- RF Electromagnetic Field||EN 61000-4-3, 10 V/m, perf. criteria A| ||- EFT (Burst) / Surge||EN 61000-4-4, ±2 kV, perf. criteria B| |||L to L:|EN 61000-4-5, ±1 kV, perf. criteria B| |||L to PE:|EN 61000-4-5, ±2 kV, perf. criteria B| ||- Conducted RF Disturbances||EN 61000-4-6, 10 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous:|EN 61000-4-8, 30 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria A| ||||60%, 10 periods, perf. criteria B| ||||>95%, 1 period, perf. criteria A| |||115 VAC / 60 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria B| ||||60%, 10 periods, perf. criteria B| ||||>95%, 1 period, perf. criteria B| ||- Voltage SagImmunity||SEMI F47,criteria A| - Voltage Sag Immunity |**General Specifications**|**General Specifications**|| |---|---|---| |Relative Humidity||95% max. (non condensing)| |Temperature Ranges|- Operating Temperature|–25°C to +70°C| ||- Case Temperature|+70°C max.| ||- Storage Temperature|–40°C to +85°C| |Power Derating|- High Temperature|2.5 %/K above 55°C| ||- Low Input Voltage|2 %/V below 100 VAC| |CoolingSystem||Natural convection(20 LFM)| |Altitude During Operation||5'000 m max.(Lower altitude required for| |||IEC61558-1 & 60335 of 3000 m)| |SwitchingFrequency||59 - 71 kHz (PWM)| |Insulation System||Reinforced Insulation| |Isolation Test Voltage|- Input to Output,60 s|3'000 VAC| |Creepage|- Input to Output|7.4 mm min.| |Clearance|- Input to Output|6.6 mm min.| |Leakage Current|- Touch Current|250µA max.| |Reliability|- Calculated MTBF|1'900'000 h(IEC 61709)| |Environment|- Vibration|IEC 60068-2-6| |||2 g, 3 axis, sine sweep, 3x60 min, 10-150 Hz| ||- Mechanical Shock|IEC 60068-2-27| |||30g,3 axis,half sine,11 ms| |Case Ingress Protection||IP 20(acc. IEC 60529)| |HousingMaterial||Plastic(UL 94 V-2 rated)| |HousingType||Plastic Case| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 4** **November 30, 2022** **www.tracopower.com** **TBLC 06 Series, 6 Watt** Mounting Type Connection Type Weight Thermal Impedance - Case to Ambient Status Indicator Environmental Compliance - REACH Declaration - RoHS Declaration DIN-Rail Mount (EN 60715 - 35x7.5mm/35x15mm) Screw Terminal 60 g 4.8 K/W typ. Indicated by green LED www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/tblc06 ## **Outline Dimensions** **==> picture [269 x 240] intentionally omitted <==** **----- Start of picture text -----**<br> 59.5<br>(2.34)<br>43.5 18.0<br>(1.71) (0.71)<br>54.5<br>Dimensions in mm (inch)<br>(2.15) Tolerances: ±0.5 (±0.02)<br>45.0 (1.77) 89.5 (3.52)<br>**----- End of picture text -----**<br> |Wiring|Wiring|Wiring| |---|---|---| |Description|Wire size|Torque| |AC Input<br>all models: L, N only<br>(2 pin terminal)|AWG 20 - 14<br>0.5 - 2.5 mm² max.|0.5 Nm| |DC Output<br>single terminal|AWG 20 - 14<br>0.5 - 2.5 mm² max.|0.5 Nm| © Copyright 2022 Traco Electronic AG Specifications can be changed without notice. Rev. November 30, 2022 www.tracopower.com **Page 4 / 4**
Updated at June 4, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →