- Manufacturer: MITSUBISHI
- Product type: Controller Accessories
- SVHC: No SVHC (15-Jan-2018)
- Product Range: -
- Current Rating: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 95.55 € |
| Current stock | 10+ |
| Lead time | 30 days |
## FACTORY AUTOMATION
## **COMPACT PLC FAMILY**
## **MELSEC PLC**
**16 million compact PLCs Networking solutions worldwide**
**Analog solutions**
**Over 35 years experience**
**Security**
**Positioning/motion control solutions**
**Global player**
## **Global impact of Mitsubishi Electric**
Through Mitsubishi Electric’s vision, “Changes for the Better“ are possible for a brighter future.
Mitsubishi Electric is involved in many areas including the following
We bring together the best minds to create the best technologies. At Mitsubishi Electric, we understand that technology is the driving force of change in our lives. By bringing greater comfort to daily life, maximising the efficiency of businesses and keeping things running across society, we integrate technology and innovation to bring changes for the better.
## **Energy and electric systems**
A wide range of power and electrical products from generators to large-scale displays.
## **Electronic devices**
A wide portfolio of cutting-edge semiconductor devices for systems and products.
## **Home appliance**
Dependable consumer products like air conditioners and home entertainment systems.
## **Information and communication systems**
Commercial and consumer-centric equipment, products and systems.
## **Industrial automation systems**
Maximising productivity and efficiency with cutting-edge automation technology.
2
**Contents**
## **Contents**
|Global leader|**4**|
|---|---|
|~~lll~~|~~lll~~|
|~~lll~~|~~lll~~|
|What makes a world leading PLC?|**5**|
|~~Pd~~|~~Pd~~|
|Range overview|**6**|
|iQ-F – the next level of industry|**7**|
|FX3U/FX3UC – a perfect PLC concept|**8**|
|FX3G/FX3GC/FX3GE – customized control|**9**|
|FX3S – new possibilities|**10**|
|Programming and software|**11**|
|Networking|**12**|
|Analog solutions|**13**|
|Drive control solutions|**14**|
|Visualization solutions|**15**|
|Your solution partner|**17**|
Section 2: Technical Informations
3
**Global leader**
## **Global leader**
The MELSEC iQ-F series is the fourth generation compact programmable controllers of Mitsubushi Electric. It offers outstanding performance, superior drive control and an intuitive programming environment.
## **16 million FX**
The FX Family of PLCs is the PLC of choice across the world, industries and applications. Mitsubishi Electric has always worked closely with its customers to design the PLC that they want for their applications. The manufacturing and use of 16 million FX CPUs is a demonstration that this close working relationship has delivered quality, reliability and the product that customers want.
## **Over 35 years**
The FX Family of PLCs has been an important part of control engineering for over 35 years. Throughout its history, the product has evolved from the original F series into today’s current iQ-F series.
The FX Family has proven to be highly reliable and it consistently improves its compatibility with previous PLC generations.
## **International acceptance**
Shipping approvals such as ABS, Lloyds Register, DNV/GL, Bureau Veritas, NK, RINA, KR for example plus CE and E1 compliance for Low Voltage and EMC directives as well as manufacturing to Automotive industry quality levels, make the FX Family PLCs products to trust.
4
**World leading PLCs**
## **What makes a world leading PLC range?**
**==> picture [466 x 323] intentionally omitted <==**
**----- Start of picture text -----**<br>
Main base unit where power<br>SD card slot is located supply, CPU, I/O and interfaces<br>Adapter units are used on the left hand side of under the front cover. are contained in a single unit.<br>the main PLC unit.<br>All FX PLC units can be mounted<br>on a DIN rail or directly mounted<br>with screw fixings.<br>" \ . . / /<br>Qiaores : feansaes then (me, ee ie es a a ee es =<br>- "<br>x pees 405$C-5<br>| a<br>4 4 rauwae© i<br>ee '= y ear xsu22, Te S03SC-5 "<br>~s ae ae P . 44<br>i ,<br>a ———EeE——EEE =<br>P —J<br>Simple ribbon<br>Optional communication boards are available in RS232C and RS485 formats. Built-in RS485 port (supporting Modbus® communication). connection links each unit together. 2 ——<br>The RUN/STOP switch has<br>become a familiar feature<br>with all FX Family PLCs. Built-in Ethernet com-munication port. Bright LED lamps indicate I/O Special function blocks<br>and power status. can be added to the right<br>hand communications<br>bus of the PLC.<br>**----- End of picture text -----**<br>
## **Ease of use**
Control systems that require minimal setup and keep program development time short.
## **Affordable**
A high performance to cost ratio makes economical design solutions for a diverse range of applications a reality.
These features combined with Mitsubishi Electric´s legacy in quality and reliability ensure that the fourth generation of micro controllers will continue to be at the forefront of the compact PLC market and provide customers with a leading edge.
## **Flexible**
A configurable design that permits open communication, large I/O handling, as well as precise positioning and analog control, creating systems that adapt to customer requirements.
## **Customer Confidence**
With a design philosophy spanning more than a quarter century, a customer base spread across the globe, a host of industrial certifications and almost 16 million CPUs sold, the FX series continues to sustain its position as the compact PLC of choice.
5
**The power to perform**
6
## **The power to perform**
**==> picture [111 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5U/FX5UC<br>With outstanding performance,<br>superior drive control, extensive<br>built-in functions and network<br>support, this PLC brings your<br>business to the next level of<br>industry.<br>**----- End of picture text -----**<br>
**==> picture [112 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U/FX3UC<br>Ultra high speed, high perfor-<br>mance and a simplified design<br>concept make this a high<br> performance micro PLC.<br>FX3G/FX3GC/FX3GE<br>Advanced control, multiple<br>communication possibilities and<br>a wide range of options make<br>this PLC an industry leader.<br>**----- End of picture text -----**<br>
mance and a simplified design concept make this a high performance micro PLC. **FX3G/FX3GC/FX3GE** Advanced control, multiple communication possibilities and a wide range of options make oemfFMO Asa this PLC an industry leader. **FX3S** A compact micro controller for simple applications, supported by a strong communications capability. **I/O** OO The FX Family of PLCs builds on previous performance and capability, ensuring you have a comprehensive range of control and automation options to choose from.
## **A solution for every application**
Micro PLCs have opened up a world of opportunities in Industrial Automation due to their small size and low cost. Now many applications benefit from enhanced performance, easier manufacturing, maintenance and greater reliability.
The FX Family has been a part of this revolution for over 35 years and has developed a range of products to suit most applications. The FX Family consists of four main ranges which are distinct and independent but compatible.
Depending on your application and control needs, you can choose from the small, economical standalone FX3S series over the powerful FX3G, FX3GC, FX3GE, FX3U and FX3UC series to the ultimate FX5U and FX5UC series.
With the FX Family there really is a solution to most applications.
|**Power supply**<br>**Maximum I/O**<br>**Digital I/O**<br>**Cycle period/**<br>**logical instruction**<br>**PLC program**<br>**memory**|100–240 V AC|100–240 V AC,<br>24 V DC|24 V DC|100–240 V AC,<br>24 V DC|100–240 V AC,<br>24 V DC|24 V DC|100–240 V AC,<br>24 V DC|24 V DC|
|---|---|---|---|---|---|---|---|---|
||30|256*|256*|256*|384**|384**|512***|512***|
||Relay/Transistor|Relay/Transistor|Transistor|Relay/Transistor|Relay/Transistor|Transistor|Relay/Transistor|Transistor|
||0.21 µs/logical<br>instruction|0.21 µs or<br>0.42 µs/logical<br>instruction|0.21 µs or<br>0.42 µs/logical<br>instruction|0.21 µs or<br>0.42 µs /logical<br>instruction|0.065 µs|0.065 µs|0.034 μs/logical<br>instruction|0.034 μs/logical<br>0.034 μs/logical<br>instruction|
||16 k steps|32 k steps|32 k steps|32 k steps|64 k steps|64 k steps|64 k steps|64 k steps|
Summary table of FX PLCs Note * : When networked with CC-Link (Discrete I/O, maximum 128); Note ** : When networked with CC-Link (Discrete I/O, maximum 256); Note *** : When networked with CC-Link/AnyWireASLINK (Discrete I/O, maximum 256)
**iQ-F – the next level of industry**
## **iQ-F – the next level of industry**
## ~~U/FX5UC at a glance~~
## **FX5U – Top of the line**
## **FX5UC – Even smaller**
**FAST INSTRUCTION TIMES** Basic instructions: 0,034 μs/ instruction (contact instruction) Applied instructions: 0,034 μs/ instruction (MOV instruction)
**==> picture [312 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
Speed Analog Speed Analog<br>| “ | “<br>shu zy she, ,<br>Communication Positioning Communication Positioning<br>Expandability Memory Expandability Memory<br>**----- End of picture text -----**<br>
## **LARGE MEMORY**
64,000 steps of built-in program memory.
**APPLICABLE STANDARDS** All products support EN and UL/cUL standards. Various shipping approvals are supported as well.
**LARGE DEVICE MEMORY** Auxiliary relays 32,768 points Timers 1024 points Counters 1024 points Data registers 8000 points Link registers 32,768 points File registers 32,768 points
The FX5UC combines the powerful features of the FX5U in an even smaller housing. This ultra-compact PLC with 24 V DC power supply and connectortype transistor I/O is designed for space conscious applications and helps to downsize your system.
The FX5U is the latest and also the most powerful compact PLC in the FX Family. Mitsubishi Electric has given the compact controllers a huge performance boost, focusing on processing power, expansion, built-in functionality and positioning & motion functions.
- aa High-speed system bus Reduced size and wiring using connector-type I/O
- aa Built-in high speed processing and positioning High-speed system bus
- High-speed system bus
- a Built-in analog inputs and analog a output
- Built-in high speed processing and positioning
- Built-in Ethernet port
- Built-in Ethernet port
- aa
- Modbus® function
- Modbus® function
- aa
- Enhanced security functions
- Enhanced security functions
- aa
- a Battery-less a
- Battery-less
- FX5 and FX3 extension modules connectable
- FX5 and FX3 extension modules connectable
7
**FX3U/FX3UC – a perfect PLC concept**
## **FX3U/FX3UC – a perfect PLC concept**
**FX3U – High performance FX3UC – Slim fit** ~~U/FX3UC at a glance~~ Speed Analog Speed Analog **FAST INSTRUCTION TIMES** Basic instructions: 0.065 μs/ instruction (contact instruction) Communication Positioning Communication Positioning Applied instructions: 0.642 μs/ instruction (MOV instruction) Expandability Memory Expandability ~~—~~ Memory **LARGE MEMORY** 64,000 steps of built-in program The FX3U is the original dual systemThe FX3UC is an ultra-compact highmemory. Flash memory cassettes bus, high-speed, fully expandable speed, fully expandable PLC. Based on with loader function are available. compact PLC designed to seamlessly 24 V DC power and using connectorcontrol communication, networking, type transistor I/O, the FX3UC is de- **APPLICABLE STANDARDS** All products support EN and UL/cUL analog, and positioning systems. With signed for space conscious and modua maximum of 384 controllable local lar applications. Created inline with the standards. Various shipping approvals are supported as well. and networked I/O via CC-Link, the FX3U FX3U series, the FX3UC incorporates uses its power and flexibility to provide such attributes as built-in high speed I/O **LARGE DEVICE MEMORY** a solution for a variety of applications. and the dual system-bus architecture, Auxiliary relays 7,680 points optimizing communication, networking, Timers 512 points 3rd generation compact PLC Counters 235 points analog, and positioning control.
Auxiliary relays 7,680 points Timers 512 points Counters 235 points Data registers 8,000 points Extension registers 32,768 points Extension file registers 32,768 points (with optional memory cassette)
High efficiency with more speed, performance, memory, and new functions
- 3rd generation super-compact PLC
- Reduced size and wiring using connector-type I/O
- Built-in high speed processing and positioning
- Built-in high speed processing and positioning
The FX3U can control a maximum of 256 connected I/O, and up to 384 points with CC-Link remote I/O.
- Even with its ultra-compact size, the FX3UC can be expanded to locally control up to 256 I/O, and up to 384 points with CC-Link remote I/O.
8
**FX3G/FX3GC – customized control**
## **FX3G/FX3GC/FX3GE – customized control**
**==> picture [463 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
Speed Analog Speed Analog Speed Analog<br>Communication Positioning Communication Positioning Communication Positioning<br>Expandability Memory Expandability Memory Expandability Memory<br>**----- End of picture text -----**<br>
## **FX3G – Customized control**
The FX3G is an introductory compact PLC and is an addition to the FX3 series, designed for simple yet performance-critical applications. Incorporating innovative FX3 series technology the customer is presented with a suite of benefits.
- 3rd generation compact PLC
- Highly flexible
- Dual system-bus architecture
Control of up to 128 directly connected I/O, or up to 256 I/O with CC-Link remote I/O.
## **FX3GE – All-in-one standard**
## **FX3GC – Super compact control**
FX3GE adds built-in analog input/output and Ethernet connectivity on top of FX3G performance.
The FX3GC expands the FX3 series line up with a connector type PLC entry model. Having the same processing capability as - the highly successful FX3G, this super com pact product reduces installation space, wiring time and potential wiring faults.
- A great fit for many applications.
- 3rd generation, all-in-one PLC
- Highly flexible
- 3rd generation super-compact PLC
- Dual system-bus architecture
- Reduced size and wiring using connector-type I/O
- Control of up to 128 directly connected I/O, or up to 256 I/O with
- Dual system-bus architecture CC-Link remote I/O.
- Control of up to 128 directly connected I/O, or up to 256 I/O with CC-Link remote I/O.
~~| G/FX3GC/FX3GE at a glance~~
## **INSTRUCTION TIMES**
Basic instructions: 0.21 μs/ instruction (contact instruction) Applied instructions: 0.42 μs/ instruction (MOV instruction)
## **LARGE MEMORY**
32,000 steps of built-in program memory. EEPROM memory cassettes with loader function (FX3G/FX3GE).
## **APPLICABLE STANDARDS**
All products support EN and UL/cUL standards. Various shipping approvals are supported as well. For FX3GC/FX3GE shipping approvals please consult your local Mitsubishi representative.
**LARGE DEVICE MEMORY** Auxiliary relays 7,680 points Timers 320 points Counters 235 points Data registers 8,000 points Extension registers 24,000 points Extension file registers 24,000 points
9
**FX3S – new possibilities**
## **FX3S – new possibilities**
## **Fit and forget**
## **FX3S– Basic micro control**
Typically FX3S applications are small, Speed Analog embedded control functions that are Communication - Positioning hidden away or unaccessible under ~ normal maintenance activities. This is Expandability Memory why the FX3S has been designed to be a robust low maintenance PLC. Features such as the maintenance free, 4000 step The FX3S adds extra expandability to the EEPROM memory and real time clock high cost performance of the venerable management all help to make the FX3S entry-level FX1S. a self managing system, reducing the impact on the maintenance engineer.
The FX3S adds extra expandability to the high cost performance of the venerable entry-level FX1S.
FX3S makes it possible to utilize analog, Ethernet and Modbus® functions even in small-scale systems.
## **Remote control**
- Basic controller for general applications
The FX3S has an additional range of BD expansion boards providing RS232, RS485, RS422 or Ethernet communications options. These can be used to connect and control various third party products such as bar code readers or panel printers.
- High performance with minimal size
## ~~S at a glance~~
## **INSTRUCTION TIMES**
Basic instructions: 0.21 μs/ instruction (contact instruction) Applied instructions: 0.5 μs/ instruction (MOV instruction)
## **MEMORY SPECIFICATIONS**
4,000 steps of built-in program memory. No battery. No maintenance.
## **APPLICABLE STANDARDS**
All products support EN and UL/ cUL standards. Please consult with your local Mitsubishi representative regarding FX3S shipping approvals.
## **DEVICE MEMORY SPECIFICATIONS**
|Auxiliary relays<br>1,536 points<br>Timers<br>138 points<br>Counters<br>67 points<br>Data registers<br>3,000 points|
|---|
|Extension file registers 2,000 points|
10
**Programming**
## **Progressive software concepts**
The Mitsubishi Electric FX PLC Family has a worldwide reputation for reliability, performance and ease of use. These key values have also been used to form Mitsubishi Electric’s integrated software concept, MELSOFT.
## **Simple programming**
The FX Family has a simple programming structure combining Basic and Applied instructions. The Basic instructions are common to all FX Family PLCs. Applied instructions provide the specialist control options such as data comparisons, PID and communications control, all of which are available on FX series. By the graded performance of each PLC series of the FX family, the number of available application instructions increases.
**==> picture [126 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
MELSOFT<br>GX Works3<br>NS wa<br>P<br>e<br>r<br>c<br>o<br>n<br>g<br>a S<br>r<br>n y<br>a<br>s<br>g<br>e t<br>n m<br>t e<br>i<br>n<br>g m<br>ai m<br>g in<br>D<br>u<br>M<br>b g<br>e<br>s<br>e<br>i<br>D<br>g<br>n<br>**----- End of picture text -----**<br>
## **Productivity tools**
Programming software for PLCs is constantly evolving. Users are placing more focus on reusable program code and function block concepts. This helps to reduce errors, reduce programming time and to help manage the whole programming process – increasing overall productivity.
## **Simple and intuitive**
The key to any good software is that it is simple to use. Mitsubishi Electric’s GX Works PLC programming packages have achieved this by using intuitive design.
GX Works3 offers also comprehensive help functions and an advanced communications layer, ensuring safe reliable communication to the target PLC.
## **Choose what you need**
Mitsubishi Electric provides with GX Works2 IEC 61131-3 compliant programming, where programs in Instruction List, Ladder, Function Block, Structured Text or SFC formats can be created. Using standard programming languages, like IEC 61131-3, on large programming projects can help users save costs by creating reusable PLC code and Function Blocks.
GX Works2 offers users the chance to **One step further** program all Mitsubishi Electric MELSEC **with iQ Works** PLCs from a single package. However, for users who only need support for FX based systems there is GX Works2 FX.
With the software suite iQ Works Mitsubishi Electric offers an integrated engineering environment. The intuitive user interface allows you to program and set up an iQ Platform, including system and network configuration, the programming of the MELSEC System Q, the MELSEC L series and the FX series, the establishment of motion controllers and servos, the design of user interfaces for operator panels of the GOT family as well as the programming of robots with the RT ToolBox2.
For the iQ-F series, Mitsubishi Electric offers the next level of PLC programming environment, GX Works3.
11
**Networking solutions**
## **Networking and communication solutions**
Applications are often required to integrate between each other across a factory, to report production or tracking data back for office based processing and in some cases be remotely monitored and maintained when the application is in an inaccessible location. The FX Family of PLCs has evolved to match this demand at all levels.
## **Easy communications**
Today’s FX Family of PLCs share a basic communication concept where additional RS232, RS422 or RS485 communications boards can be added to the main base unit without increasing the required cabinet space. These can then be used for communication to various third party devices like bar code readers, printers and modems.
FX3 Family PLCs have a wider range of communications modules. These include options for connection to open and bespoke networks such as Ethernet, Profibus DP, CC-Link, DeviceNet™, CANopen or Modbus® for example.
FX Family PLCs have a wide range of commu nications options.
## **Networks make sense**
Networked solutions to complex applications often make the overall solution easier to achieve and more cost effective. For example a conveyor system integrated with a warehouse pick and place system may extend over many hundreds of meters, and by using a fieldbus, such as CC-Link, wiring, troubleshooting and maintenance can be dramatically reduced.
## **Remote maintenance**
With communications technology it is possible to put PLC control in the most remote locations. Using a PLC connected to a telemetry solution, such as a GSM modem, allows the user to remotely monitor and maintain the system. It can also allow the remote system to send alarm messages, warnings or general status information back to the user’s central data processing centre.
Example of remote pumping station.
The built-in Ethernet port of the FX5U and FX5UC base units allows for the connection to a personal computer or communication to other devices. The FX5U and FX5UC additionally offer an integrated RS485 port that allows to connect up to 16 Mitsubishi inverters or using Modbus® communication up to 32 devices like temperature controllers etc.
12 e
**Analog solutions**
## **Analog solutions**
Analog control is one of the most important areas for any automation system. Critically for users the concern is to match the performance demanded by the application to the available solutions in a cost effective way.
## **Where is analog used?**
Analog control is widely used. In simple terms it allows a variable signal to be used to control items such as a motor’s speed or to sense inputs such as fluid levels.
## **Digital to analog (D-A) control**
Here a digital PLC value is output as an analog signal. It can be used, for example, to send a speed command to an inverter which in turn causes the motor to increase or decrease speed.
## **Analog to digital (A-D) control**
In this type of control a variable signal is sent to a PLC where it is converted in to a direct digital value. An example of this could be the measurement of the level of a liquid in a storage tank so that the exact amount of stored liquid can be controlled by the PLC.
**==> picture [138 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inverter Example:<br>D-A control can<br>be used to set the<br>speed of an inverter<br>driving a motor.<br>Example:<br>Temperature<br>control keeps the<br>liquid at the correct<br>viscosity.<br>Example:<br>A-D control can be<br>used to control the<br>filling speed of the<br>container.<br>**----- End of picture text -----**<br>
## **Temperature control**
Temperature control is the third type of analog control. An example of use could be where the temperature of a furnace is measured and compared by the PLC against a set range. Additional heating or cooling can then be applied to maintain a constant temperature.
Analog solutions are an important part of control engineering and can be used to simplify and accurately control actions happening in the production environment.
Example of temperature control.
## **Solutions to choose from**
The FX Family offers a wide range of analog solutions from 1 and 2 channel BD boards for FX3G up to 8 channel input blocks like the FX2N-8AD where temperature, voltage and current input can be mixed on the same block. FX analog blocks also come in a range of resolutions from 8 bit up to 16 bit signal processing.
The FX3GE and FX5U base units are equipped with 2 analog input channels and 1 analog output channels.
With this range of choice and flexibility it is sure that there will be a solution here for most applications.
13
**Drive control solutions**
## **Drive control solutions**
Using simple positioning solutions can help increase the accuracy of the work process, reduce waste and rework as well as provide a higher quality of production.
## **High speed counter input**
X-Y table for simple shaping
When a motor is being driven, its relative position can be controlled by counting the number of output pulses.
However, for a more accurate process, reading the actual position from an encoder feedback directly into a high speed counter is preferred. This helps to overcome issues of backlash and slippage as the actual position is measured and not assumed.
## **Positioning built in as standard**
FX PLCs come with high speed counters (up to 200 kpps) and pulse train outputs (up to 200 kpps) as standard. The high speed counters can be configured in single pulse train inputs. The high speed counters can be configured in a single or two phase input. Pulse train outputs can be configured to provide continuous pulse streams at different frequencies or a set quantity of pulses at a single frequency.
Horizontal drill station Z WD Vertical © u drill station
Z> Z
There are also optional modules and adapters that can provide additional high speed counters with performance up to 200 kpps. The same is true for pulse train outputs with 200 kpps and 1 Mpps (1 MHz) output options available.
Simple positioning solutions can be effectively managed within a standard FX PLC.
## **Typical applications**
## **Pulse train outputs**
A stream of output pulses can be used as a drive signal to a line driver, stepper motor or servo amplifier, which then causes the connected motor to perform the positioning activity.
Simple positioning applications typically involve independently controlled operational axis and can sometimes have many requirements. In the example of an X-Y table, a relative position is achieved by driving each axis until its target position is achieved, regardless of what happens with the other axis. There are two main elements to achieve this type of positioning control.
Example of conveyor belt control.
The larger the range of output pulse frequencies available means greater speed and/or accuracy is achievable. For example, if a stepper motor with a larger number of steps is used, the travel distance per step can be reduced, resulting in an increased system accuracy.
14
**Visualization solutions**
## **Visualization solutions**
An increasingly important area of any automation solution is the reporting and display of operational information. This data enables operators, maintenance teams and business managers to make informed decisions in the best interests of the business.
In the food industry hygiene is very important.
The FX3U-7DM can be directly mounted within the PLC (FX3U) or mounted on the front cabinet.
## **The right tool for the right job**
For maximum efficiency, each user requires access to information at their work place in a form that highlights the important data for them first. This means a range of different tools are required. As an example, here are three possible scenarios.
## **The machine operator**
Machines often have a lot of manufacturing debris around or are subject to hygienic cleaning as in the food industry. Any display located in this environment would need to have a high Ingress Protection (IP) rating, indicating a high degree of waterproofness.
It may also be a benefit to the operator to have a large and clear display to reduce the chances for error from misreading, due to poor light or small fonts being used. It is also recognized that the use of graphics also reduces the chances for reading errors with complex data.
## **The business manager**
In a production controllers office it would be better to display information through a network to their existing desktop PC. In this application a piece of software such as an OPC server/client, a Java applet, an Active X control or a SCADA system would allow lots of data from lots of sources to be displayed in a clear and concise way giving the production controller the overview of the business operation that they need.
## **Data the way you want it**
Mitsubishi Electric offers a wide range of visualization solutions from simple data displays such as the FX3U-7DM, advanced Graphic Operator Terminals like the GOT series, and a wide choice of software solutions from the MELSOFT software suite.
This powerful combination of hardware and software means there is a cost effective solution for most applications.
## **The maintenance team**
The GOT is a typical HMI
The critical information for a maintenance engineer is the error and diagnostic data within the PLC as this is used to diagnose any process problems. However, additional information regarding the operational “hours run” or cycles processed, which could be called soft information as it is calculated on operational parameters, could allow the maintenance engineer to predict possible failure and arrange preventative maintenance.
Access to this data could be through the machine operator’s terminal, across a network or through a dedicated display mounted inside or on the control cabinet itself.
15
**Application solutions**
## **Where have FX PLCs been used?**
## Food and drink
- Bread manufacture (mixing/baking) – Food processing (washing/sorting/ slicing/packaging)
## Leisure
- Multiplex cinema projection
- Animated mechatronics
- (museums/theme parks)
## Medical
- Respiration machine testing
- Sterilization
- Pharmaceutical/chemical
- Dosing control
- Polution measurement systems
- Cryogenic freezing
- Gas chromotography
- Packaging
## Plastics
- Plastic welding systems
- Energy management systems for injection molding machines – Loading/unloading machines
- Blow molding test machines
- Injection molding machines
Sanitation management on Eurostar rollingstock.
Printing
Textiles
Customer applications with FX PLCs have been wide spread from critical applications in pharmaceutical industries to sublime applications in the leisure industry. However, the FX PLC Family still remains the PLC of choice for many machine builders as it is flexible, compact and easy to use, which is why it is so often used.
Here are just a few examples of applications that customers have completed in the past:
## Agriculture
- Plant watering systems
- Plant handling systems
- Saw mill (wood)
- Building management
- Smoke detection monitoring
- Ventilation and temperature control
- Lift (elevator) control
- Automated revolving doors
- Telephone management
- Energy management
- Transportation
- Sanitation on passenger ships
- Sanitation on rail rolling stock
- Fire tender, pump management
- Waste disposal truck management
- Utilities
- Waste water treatment
- Fresh water pumping
- Swimming pool management
- Construction
- Steel bridge manufacturing
- Tunnel boring systems
16 @
ALPHA FX3S FX3G FX3GC FX3GE FX3U FX3UC FX5U FX5UC
## **Technical Information Section**
## **Further publications within the industrial automation range**
## **Modular PLC Family**
##
Product catalogues for programmable logic controllers and accessories for the MELSEC iQ-R series/System Q/L series
## **HMI Family**
Product catalogue for operator terminals, supervision software and accessories
## **FR Family**
Product catalogue for frequency inverters and accessories
## **MR Family**
Product catalogue for servo amplifiers and servo motors as well as motion controller and accessories
## **Robots Family**
Product catalogue for industrial robots and accessories
## **LVS Family**
Product catalogue for low voltage switchgears,magnetic contactors and circuit breakers
## **Automation Book**
Overview on all Mitsubishi Electric automation products, like frequency inverters, servo/motion, robots etc.
## **More information?**
This product catalogue is designed to give an overview of the extensive range FX Family of MELSEC PLCs. If you cannot find the information you require in this catalogue, there are a number of ways you can get further details on configuration and technical issues, pricing and availability.
For technical issues visit the https://eu3a.mitsubishielectric.com website. Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products and services. Manuals and catalogues are available in several different languages and can be downloaded for free.
For technical, configuration, pricing and availability issues contact our distributors and partners. Mitsubishi Electric partners and distributors are only too happy to help answer your technical questions or help with configuration building. For a list of Mitsubishi Electric partners please see the back of this catalogue or alternatively take a look at the “contact us” section of our website https://eu3a.mitsubishielectric.com.
## **About this product catalogue**
This catalogue is a guide to the range of products available. For detailed configuration rules, system building, installation and configuration the associated product manuals must be read. You must satisfy yourself that any system you design with the products in this catalogue is fit for purpose, meets your requires and conforms to the product configuration rules as defined in the product manuals.
Specifications are subject to change without notice. All trademarks acknowledged.
© Mitsubishi Electric Europe B.V., Factory Automation - European Business Group
## **The products of Mitsubishi Electric Europe B.V., that are listed and described in this document, are neither subject to approval for export nor subject to the Dual-Use List.**
2
Contents
~~**1**~~
~~**2**~~
~~**3**~~
~~**4**~~
~~**5**~~
~~**6**~~
~~**7**~~
~~**8**~~
## ~~**1 Introduction and configuration**~~
|~~**1**~~|~~**Introduction and configuration**~~|
|---|---|
|�<br> �<br> �<br> �<br> �<br> �<br> �<br> �|Product overview MELSEC iQ-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br>Product overview MELSEC-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br>FX series selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br>Components for an FX PLC system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br>FX series configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br>Calculation of the power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br>MELSEC iQ-F – FX5 advanced built-in functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br>MELSEC-F – FX3 built-in functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25|
|~~**2**~~|~~**MELSEC FX base units**~~|
|�<br> �<br> �<br> �<br> �<br> �<br> �<br> �|FX5U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br>FX5UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29<br>FX3S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br>FX3G series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br>FX3GE series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br>FX3GC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39<br>FX3U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br>FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46|
|~~**3**~~|~~**MELSEC FX I/O extension**~~|
|�<br> �|Powered extension units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br>Unpowered extension modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51|
## ~~**4 MELSEC FX special function modules**~~
|�<br> �<br> �<br> �|Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55<br>Temperature control modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58<br>Data logger module, high-speed counter modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br>Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60||
|---|---|---|
|�|Simple Motion modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61||
|�<br> �<br> �<br> �|Network modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br>Communications modules, interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br>Adapter boards, communications adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br>Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73||
|~~**5**~~|~~**Accessories**~~||
|�<br> �<br> �<br> �<br> �<br> �<br> �<br> �|Expansion adapter, conversion modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74<br>Conversion adapter, memory cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75<br>External terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br>Cable and connection terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br>Power supply units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br>Backup batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79<br>Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br>Display modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81||
|~~**6**~~|~~**ALPHA controllers**~~||
|�<br> �|Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br>Extension units and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85||
|~~**7**~~|~~**Dimensions**~~||
|�<br> �<br> �<br> �<br> �|Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87<br>Extension units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br>Special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br>Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br>ALPHA series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97||
|~~**8**~~<br> �<br> �|~~**Software & programming**~~<br>Programming software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98<br>Programming unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101||
||Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103<br>Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106||
3
Product overview
~~**1**~~
## **MELSEC iQ-F series**
## **The next generation of FX controllers**
Designed on the concepts of outstanding performance, superior drive control and user centric programming, Mitsubishi's MELSEC-F series has been reborn as the MELSEC iQ-F series. From stand alone use to networked system applications, the MELSEC iQ-F series brings your business to the next level of industry.
## **MELSEC iQ-F**
**==> picture [25 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5U<br>**----- End of picture text -----**<br>
|**CPU module**<br>1<br>2<br>3|**FX5U-32MR/ES**|**FX5U-32MR/DS**|**FX5U-64MR/ES**|**FX5U-64MR/DS**|**FX5U-80MR/ES**|**FX5U-80MR/DS**|
|---|---|---|---|---|---|---|
||**FX5U-32MT/ES**|**FX5U-32MT/DS**|**FX5U-64MT/ES**|**FX5U-64MT/DS**|**FX5U-80MT/ES**|**FX5U-80MT/DS**|
||**FX5U-32MT/ESS**|**FX5U-32MT/DSS**|**FX5U-64MT/ESS**|**FX5U-64MT/DSS**|**FX5U-80MT/ESS**|**FX5U-80MT/DSS**|
|DC input type|Sink/source||Sink/source||Sink/source||
|I/Opoints|Upto 256 local, upto 512 incl. network I/O´s||Upto 256 local, upto 512 incl. network I/O´s||Upto 256 local, upto 512 incl. network I/O´s||
|Program size<br>K step|64||64||64||
|Engineeringenvironment|GX Works3||GX Works3||GX Works3||
|Built-in analog I/O|2 input channels (voltage)<br>1 output channel (voltage)||2 input channels (voltage)<br>1 output channel (voltage)||2 input channels (voltage)<br>1 output channel (voltage)||
|Built-in Ethernet port|ü||ü||ü||
## **FX5UC**
|**CPU module**<br>1<br>2|**FX5UC-32MT/D**1|**FX5UC-64MT/D**1|
|---|---|---|
||**FX5UC-32MT/DSS**2|**FX5UC-64MT/DSS**2|
|DC input type|1Sink<br>2Sink/source|1Sink<br>2Sink/source|
|I/O points|Up to 256 local,<br>up to 512 incl. network I/O´s|Up to 256 local,<br>up to 512 incl. network I/O´s|
|Program size<br>K step|64|64|
|Engineeringenvironment|GX Works3|GX Works3|
|Built-in analogI/O|—|—|
|Built-in Ethernet port|ü|ü|
Output type:
1 Relay output 2 Transistor output (sink) 3 Transistor output (source)
4
Product overview
~~**1**~~
## **MELSEC-F series**
## **The third generation of micro programmable controller, the FX3 series**
The FX series is renowned for its speed, capacity, performance and extensive features. Integrated with many features including analog inputs/ outputs, communication, Ethernet and positioning, the FX3 series realizes high-performance in many different applications.
## **MELSEC-F**
|**CPU module**<br>1<br>2<br>3|**FX3S-10MR/ES,**<br>**FX3S-14MR/ES,**<br>**FX3S-20MR/ES,**<br>**FX3S-30MR/ES,**<br>**FX3S-30MR/ES-2AD**<br>**FX3S-10MR/DS,**<br>**FX3S-14MR/DS,**<br>**FX3S-20MR/DS,**<br>**FX3S-30MR/DS**|**FX3S-10MR/DS,**<br>**FX3S-14MR/DS,**<br>**FX3S-20MR/DS,**<br>**FX3S-30MR/DS**<br>**FX3G-14MR/ES,**<br>**FX3G-24MR/ES,**<br>**FX3G-40MR/ES,**<br>**FX3G-60MR/ES**|**FX3G-14MR/DS,**<br>**FX3G-24MR/DS,**<br>**FX3G-40MR/DS,**<br>**FX3G-60MR/DS**|**—**|**FX3GE-24MR/ES,**<br>**FX3GE-40MR/ES**|**FX3GE-24MR/ES,**<br>**FX3GE-40MR/ES**<br>**FX3GE-24MR/DS,**<br>**FX3GE-40MR/DS,**|
|---|---|---|---|---|---|---|
||**FX3S-10MT/ES,**<br>**FX3S-14MT/ES,**<br>**FX3S-20MT/ES,**<br>**FX3S-30MT/ES,**<br>**FX3S-30MT/ESS-2AD**<br>**FX3S-10MT/DS,**<br>**FX3S-14MT/DS,**<br>**FX3S-20MT/DS,**<br>**FX3S-30MT/DS**|**FX3S-10MT/DS,**<br>**FX3S-14MT/DS,**<br>**FX3S-20MT/DS,**<br>**FX3S-30MT/DS**<br>**FX3G-14MT/ES,**<br>**FX3G-24MT/ES,**<br>**FX3G-40MT/ES,**<br>**FX3G-60MT/ES**|**FX3G-14MT/DS,**<br>**FX3G-24MT/DS,**<br>**FX3G-40MT/DS,**<br>**FX3G-60MT/DS**|**FX3GC-32MT/D**|**FX3GE-24MT/ES,**<br>**FX3GE-40MT/ES**|**FX3GE-24MT/ES,**<br>**FX3GE-40MT/ES**<br>**FX3GE-24MT/DS,**<br>**FX3GE-40MT/DS,**|
||**FX3S-10MT/ESS,**<br>**FX3S-14MT/ESS,**<br>**FX3S-20MT/ESS,**<br>**FX3S-30MT/ESS,**<br>**FX3S-30MT/ES-2AD**<br>**FX3S-10MT/DSS,**<br>**FX3S-14MT/DSS,**<br>**FX3S-20MT/DSS,**<br>**FX3S-30MT/DSS**|**FX3S-10MT/DSS,**<br>**FX3S-14MT/DSS,**<br>**FX3S-20MT/DSS,**<br>**FX3S-30MT/DSS**<br>**FX3G-14MT/ESS,**<br>**FX3G-24MT/ESS,**<br>**FX3G-40MT/ES,**<br>**FX3G-60MT/ESS**|**FX3G-14MT/DSS,**<br>**FX3G-24MT/DSS,**<br>**FX3G-40MT/DSS,**<br>**FX3G-60MT/DSS**|**FX3GC-32MT/DSS**|**FX3GE-24MT/ESS,**<br>**FX3GE-40MT/ESS**|**FX3GE-24MT/ESS,**<br>**FX3GE-40MT/ESS**<br>**FX3GE-24MT/DSS,**<br>**FX3GE-40MT/DSS**|
|DC input type|Sink/source|Sink/source||Sink/source|Sink/source||
|I/O points|Up to 30 local|Up to 128 local, up to 256 incl. network I/O´s||Up to 128 local, up to<br>256 incl. network I/O´s|Up to 128 local, up to 256 incl. network I/O´s||
|Program size<br>K step|4|32||32|32||
|Engineeringenvironment|GX Works2|GX Works2||GX Works2|GX Works2||
|Built-in analog I/O|FX3S-30M:<br>2 input channels (voltag|ge)<br>—||—|2 input channels (voltage)<br>1 output channel (voltage)||
|Built-in Ethernet port|—|—||—|ü||
**FX3U FX3UC 16–128 I/O 16–96 I/O Power supply AC DC DC FX3U-16MR/ES, FX3U-32MR/ES, FX3U-16MR/DS, FX3U-32MR/DS,** 1 **FX3U-48MR/ES, FX3U-64MR/ES, FX3U-48MR/DS, FX3U-64MR/DS, FX3UC-16MR/D-T**[4] **, FX3UC-16MR/DS-T FX3U-80MR/ES, FX3U-128MR/ES FX3U-80MR/DS FX3U-16MT/ES, FX3U-32MT/ES, FX3U-16MT/DS, FX3U-32MT/DS, CPU module** 2 **FX3U-48MT/ES, FX3U-64MT/ES, FX3U-48MT/DS, FX3U-64MT/DS, FX3UC-16MT/D FX3UC-64MT/D**[4][4] **, FX3UC-32MT/D , FX3UC-96MT/D**[4][4] **, FX3U-80MT/ES, FX3U-128MT/ES FX3U-80MT/DS FX3U-16MT/ESS, FX3U-32MT/ESS, FX3U-16MT/DSS, FX3U-32MT/DSS, FX3UC-16MT/DSS, FX3UC-32MT/DSS,** 3 **FX3U-48MT/ESS, FX3U-64MT/ESS, FX3U-48MT/DSS, FX3U-64MT/DSS, FX3UC-64MT/DSS, FX3UC-96MT/DSS FX3U-80MT/ESS, FX3U-128MT/ESS FX3U-80MT/DSS** Input type DC input sink/source DC input sink/source (except[4] : DC input sink) I/O points Up to 256 local, up to 384 incl. network I/O´s Up to 256 local, up to 384 incl. network I/O´s Program size K step 64 64 Engineering environment GX Works2 GX Works2
Output type: 1 Relay output 2 Transistor output (sink) 3 Transistor output (source)
5
System description
~~**1**~~
## **FX series selection guide**
**==> picture [512 x 678] intentionally omitted <==**
**----- Start of picture text -----**<br>
Select system item Select item specification Select an applicable FX model<br>Terminal-type I/O Connector-type I/O<br>Non-extendable* Extendable Extendable<br>System item Item specification* FX3S FX3G FX3GE FX3U FX5U FX3GC FX3UC FX5UC<br>Up to 30 local I/O's P p p p p p p p<br>Up to 128 local I/O's P P p p P p p<br>Up to 256 local I/O's P P P P<br>I/O points '<br>Up to 256 local and network I/O s P P p p P p p<br>Up to 384 local and network I/O's P p P p<br>Up to 512 local and network I/O's P P<br>AC power P P P P P<br>Power supply<br>DC power P P P P P P<br>100 V AC P P [3] P [3]<br>Input type<br>24 V DC P P P P P P P P<br>Relay P P P P P P<br>Output type Transistor P P P P P P P P<br>Triac P P [3] P [3]<br>Standard P P P p p P p p<br>CPU speed Advanced P p P p<br>High-speed P P<br>USB P P P P<br>Communication RS422 P P P P P P<br>ports RS485 P P<br>Ethernet P P P<br>Analog I/O Input: 2, output: 1 P P<br>Up to 4 ADP channels P P P P p P P p<br>Up to 8 ADP channels P [1] p p P p p<br>Analog I/O<br>(current/ Up to 16 ADP channels P P P P<br>voltage) Up to 64 special function block input channels P P P p P P p<br>Up to 128 special function block input channels P P<br>Up to 4 ADP input channels P P P P p P P p<br>Up to 8 ADP input channels P [1] p p P p p<br>Temperature Up to 16 ADP input channels P P P P<br>sensor input<br>Up to 64 special function block input channels P P P P P P P<br>Temperature control P P P P P P P<br>CC-Link (Master/Slave) P P P P P P P<br>CANopen® P P P P P<br>J1939 P P P P P<br>Network<br>Ethernet P P P P P P P P<br>Master P P<br>Profibus DP<br>Slave P P P P P<br>N : N network/parallel link P P P P P P P P<br>Computer link (RS232C/RS485) P P P P P P P P<br>1 channel (RS232C/RS485) P p P p P p p P<br>Non-protocol communication Multi-channel (RS232C) P P P P P P<br>Multi-channel (RS485) P P P P P P<br>Communication RS422 P<br>Add-on RS485 P P P P P P P<br>communication<br>RS232C P P P P P P P<br>ports<br>USB P<br>Embedded USB P P P P<br>Modbus® P P P P P P P P<br>Analog P P P P P P P P<br>Inverter control Pulse width modulation P P P P P P P P<br>RS485 communication P P P P P P P P<br>1 to 2 x 100 kHz axis built-in positioning P P P p p P p p<br>Up to 3 x 100 kHz axis built-in positioning P [2] P [2] P P P P<br>Up to 4 x 200 kHz axis with high-speed output adapters P<br>Up to 4 x 200 kHz axis built-in positioning P P<br>Positioning<br>Up to 8 x 1 MHz axis with special function blocks P P<br>Up to 16 SSCNETIII axis with special function blocks P p P p<br>Up to 64 SSCNETIII axis with special function blocks P P<br>Cam switching P P<br>Up to 6 high speed counters, max. 60 kHz P P P p p P p p<br>High-speed Up to 8 high speed counters, max. 100 kHz P p P p<br>counters Up to 8 high speed counters, max. 200 kHz P P P<br>Additional extension using high-speed counter block P P P P<br>Storage Source data storage P P P P<br>CF card adapter P P<br>Data logging<br>SD card P P<br>Hardware<br>Options<br>**----- End of picture text -----**<br>
P : Contains required functionality p : Higher functionality or more expandability 1 14 and 24 I/O points main units : max. 4 channels 2 14 and 24 I/O points main units : max. 2 axes 3 When a terminal module is used.
* Some items require additional extension modules in order to function where other connection rules and requirements may apply. For more details, refer to the respective product manuals.
6
System description
~~**1**~~
## **What components are required for an FX PLC system?**
A basic FX PLC system can consist of a standalone base unit, with the functionality and I/O range increased by adding extension I/O and special function modules. The following section provides an overview of options available.
## **Base units**
The FX3S, FX3G, FX3U and FX5U can be AC or DC powered, the FX3GC, FX3UC and the FX5UC are only DC powered, both with a mix of input and output styles. The PLCs can be programmed with the user friendly GX Works2/GX Works2 FX (FX3 PLCs) and GX Works3 (FX5 PLCs) programming software, allowing programs to be transferred between different FX PLCs. All PLC base units include an integrated real time clock.
Base units are available with different I/O configurations from 10 to 128 points but can be expanded to 512 points depending upon the FX range selected.
## **Extension boards**
Except for the FX3GC, FX3UC and FX5UC series, extension adapter boards can be installed directly into the base unit and therefore do not require any additional installation space.
Programming is done directly via special commands and dedicated data register in the PLC. For a small number of digital I/O (2 to 4) an extension adapter board can be installed directly into the FX3S, FX3G, FX3GE, FX3U or FX5U controller. Interface adapter boards can also provide the FX PLC with additional RS232, RS422, RS485 or USB interfaces.
## **Special adapters**
The special Adapters, also called ADPs, add standard high-speed functions to a FX PLC. Mounted on the left side of a base unit, these units are extremely compact and easy to use. The programming is similar to the expansion boards via special instructions and dedicated data registers in the PLC.
Available are various serial communication, analog, temperature input, positioning, highspeed counting and data logging ADPs. Compared to the BDs the ADPs offer more flexibility and performance. For the connection of ADP modules, a converter adapter is required for some base units.
## **Extension I/O modules**
Unpowered and powered extension digital I/O modules can be added to the FX3G, FX3GC, FX3GE, FX3U, FX3UC, FX5U and FX5UC PLCs.
A wide range from 8 to 48 I/O points with different inputs and outputs are available. There is no limitation on the number of extension units or blocks, you can design the system to match application requirements, just make sure to check the system power supply and number of available I/O points.
Dedicated I/O blocks for the FX3GC and FX3UC are available as well.
## **Special function modules**
A wide variety of special function modules are available for the FX3G, FX3GC, FX3GE, FX3U FX3UC, FX5U and FX5UC PLCs. They cover networking functionality, analog control, high speed input, pulse train outputs, data logging function, temperature inputs and Simple Motion modules.
Thanks to the standardized communication via memory integrated into the special function modules, programming is straightforward.
The integrated CPU performs PLC scan time independent operation perfectly fitted for networking or positioning tasks, thus reducing the load on the PLC base unit. Up to 8 different units can be connected to the base unit.
## **Memory extension and operator terminals**
Each FX family base unit (except FX3GC/FX5U/ FX5UC) can be equipped with a memory cassette. The programming unit interface enables the connection of programming tools like PC and hand held programming units as well as graphical operator terminals.
**==> picture [391 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
I/O extension Special function<br>block<br>Main unit<br>Adapter<br>Expansion<br>board<br>**----- End of picture text -----**<br>
7
System description
~~**1** |~~
**==> picture [490 x 339] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|FX3 expansion adapter|
|FX series configuration|
|FX3U CPU module|
|FX3U|id1|FX3 extension module|
|Expansion board|
|Communication|Interface board|FX3 expansion board|
|FX3U-232-BDFX3U-422-BD|OR|FX3U-CNV-BD|
|FX3U-485-BD|Analog setpoint|
|i|1|FX3U-422-BD|FX3U-USB-BD|i|||FS|FX3U-8AV-BD|
|CPU module|
|Expansion adapter|
|f|=|
|Ss|i|re)|s|lii|x|a|Be.|2502338)ie|
|FX3U-32M|DCAC|AC power supplyDC power supply|T1R|Relay outputTransistor (sink)|
|D|DC input (sink/source)|T2|Transistor (source)|
|ay|=|i|tN|g|a|FX3U main unit 16–128 I/O||||E|AC input||__||TR|Triac output|
|FX3U-16MR/ES|AC|D|R|FX3U-48MR/ES|AC|D|R|
|FX3U-16MT/ES|AC|D|T1|FX3U-48MT/ES|AC|D|T1|
|FX3U-ENET-ADP|FX3U-4AD-PTW-ADP|FX3U-4HSX-ADP|FX3U-16MT/ESS|AC|D|T2|FX3U-48MT/ESS|AC|D|T2|
|FX3U-16MR/DS|DC|D|R|FX3U-48MR/DS|DC|D|R|
|Communication|Analog|High-speed counter|FX3U-16MT/DS|DC|D|T1|FX3U-48MT/DS|DC|D|T1|
|FX3U-232ADP-MB|FX3U-4AD-ADP|FX3U-4HSX-ADP|FX3U-16MT/DSS|DC|D|T2|FX3U-48MT/DSS|DC|D|T2|FX3U-80MR/ES|AC|D|R|
|a|FX3U-485ADP-MBFX3U-ENET-ADP|Network|[1]|PS|FX3U-4DA-ADPFX3U-3A-ADP FX3U-4AD-PT-ADP|Temperature|[2]|a|FX3U-2HSY-ADP|Positioning|FX3U-32MR/ESFX3U-32MT/ESFX3U-32MT/ESSFX3U-32MS/ESFX3U-32MR/DS||===a|DCACACACAC|||DDDDD|||TRT1T2RR|FX3U-64MR/ESFX3U-64MT/ESFX3U-64MT/ESSFX3U-64MS/ESFX3U-64MR/DS||=aosTI|DCACACACAC|||DDDDD|||TRT1T2RR|FX3U-80MT/ESFX3U-80MT/ESSFX3U-80MR/DSFX3U-80MT/DSFX3U-80MT/DSS|ptT_Tcor+}|DCDCDCACAC|DDDDD|T1T2T1T2R|
|a|FX3U-CF-ADP|Data logging|[2]|FX3U-4AD-TC-ADPFX3U-4AD-PTW-ADPFX3U-4AD-PNK-ADP|FX3U-32MT/DSFX3U-32MT/DSSFX3U-32MR/UA1|HTToo+7|DCDCAC|DDE|T1T2R|FX3U-64MT/DSFX3U-64MT/DSSFX3U-64MR/UA1|==oTJ|DCDCAC|DDE|T1T2R|FX3U-128MR/ESFX3U-128MT/ESFX3U-128MT/ESS|oo=|ACACAC|DDD|T1T2R|
|1 Firmware version 3.10 or later. 2 Firmware version 2.61. 3 Firmware version 3.00 or later.|
**----- End of picture text -----**<br>
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3 expansion adapter<br>**----- End of picture text -----**<br>
**==> picture [104 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3UC CPU module<br>FX3 extension module<br>**----- End of picture text -----**<br>
## **Expansion adapter**
**==> picture [48 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPU module<br>**----- End of picture text -----**<br>
**==> picture [477 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-ENET-ADP FX3U-232ADP-MB FX3U-4AD-ADP FX3U-4AD-PNK-ADP<br>Network Communication Analog Temperature<br>FX3U-ENET-ADP [1] FX3U-232ADP-MB FX3U-4AD-ADP FX3U-4AD-PT-ADP FX3UC main<br>FX3U-485ADP-MB FX3U-4DA-ADP FX3U-4AD-TC-ADP unit 16–96 I/O FX3UC-64M<br>FX3U-3A-ADP [2] FX3U-4AD-PTW-ADP<br>FX3U-4AD-PNK-ADP FX3UC-16MT/D* DC D1 T1 DC DC power supply<br>) FX3UC-16MT/DSS ef DC D2 T2 D1 DC input (sink)<br>FX3UC-16MR/D-T* DC D1 R D2 DC input(sink/source)<br>FX3UC-16MR/DS-T DC D2 R R Relay output<br>Data logging FX3UC-32MT/D* DC D1 T1 T1 Transistor output (sink)<br>FX3U-CF-ADP [2] FX3UC-32MT/DSS DC D2 T2 T2 Transistor output (source)<br>LY ry =<br>FX3UC-64MT/D* DC D1 T1<br>NE FX3UC-64MT/DSS DC D2 T2 * Refer to the hardware manual for<br>FX3UC-96MT/D* =m DC D1 T1 system configuration.<br>FX3U-CF-ADP FX3UC-96MT/DSS = DC D2 T2<br>ae a Memory cassette a Connecting to terminal block<br>FX3U-FLROM-16 TB-EX-CAB-1M (1 m)<br>FX3U-FLROM-64 TB-EX-CAB-3M (3 m)<br>FX3U-FLROM-64L TB-EX-CAB-5M (5 m)<br>FX3U-FLROM-64L u ——__—__j J FX3U-FLROM-1M [3] {i } TB-EY-CAB-1M (1 m)<br>**----- End of picture text -----**<br>
## **Option**
1 Firmware version 3.10 or later. 2 The FX3UC supports the FX3U-CF-ADP and FX3U-3A-ADP from firmware version 2.61. 3 Firmware version 3.00 or later.
8
System description
~~**1**~~
## **Extension module**
**==> picture [478 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
a I/O extension module<br>Powered extension unit Unpowered extension block<br>Input/output extension unit Input extension block Output extension block<br>FX2N-32ER-ES/UL FX2N-8EX-ES/UL FX2N-8EYR-ES/UL<br>FX2N-32ET-ESS/UL FX2N-8EX-UA1/UL FX2N-8EYT-ESS/UL<br>FX2N-48ER-DS FX2N-16EX-ES/UL FX2N-16EYR-ES/UL<br>FX2N-48ER-ES/UL FX2N-16EYT-ESS/UL<br>FX2N-48ER-UA1/UL Input/output extension block FX2N-16EYS<br>FX2N-48ET-DSS FX2N-8ER-ES/UL<br>FX2N-48ER FX2N-48ET-ESS/UL FX2N-8EX FX2N-16EYR<br>a Power supply unit | Special function block<br>Analog Positioning Network<br>] x on ___N oA __N FX0N-3A FX2N-1PG-E FX2N-32CCL<br>FX2N-2AD FX3U-1PG FX3U-16CCL-M [1]<br>FX3U-4AD FX2N-10PG FX3U-64CCL<br>FX2N-2DA FX3U-20SSC-H FX3U-ENET<br>FX3U-4DA FX2N-1RM-E-SET FX3U-32DP<br>FX2N-5A FX2N-10GM FX3U-64DP-M<br>FX2N-8AD FX2N-20GM FX3U-CAN<br>FX3U-1PSU-5V FX3U-J1939<br>FX0N-3A FX3U-20SSC-H FX3U-64CCL Temperature High-speed counter Communication<br>as Power supply unit FX2N-2LC FX2N-4AD-TC FX2N-1HC FX2N-232IF<br>FX3U-1PSU-5V FX3U-4LC FX2N-4AD-PT FX3U-2HC<br>Option<br>— FX3U-FLROM-16 a Memory cassette MITSUBISHI ELSES =e FX3U-7DM | Display module eS FX0N-30EC (30 cm) P| Extension cable<br>—— FX3U-FLROM-64FX3U-FLROM-64LFX3U-FLROM-1M [3] FX3U-7DM-HLD Display module holder FX0N-65EC a Battery FX0N-65EC (65 cm)FX2N-CNV-BC PLC bus connector<br>FX3U-FLROM-64L FX3U-7DM FX3U-32BL<br>**----- End of picture text -----**<br>
**==> picture [523 x 289] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extension module<br>a I/O extension module<br>— ooo Input extension block<br>Input extension block FX2N-8EX-ES/UL<br>FX2NC-16EX-T-DS FX2N-8EX-UA1/UL<br>FX2NC-16EX-DS Power supply unit FX2N-16EX-ES/UL<br>FX2NC-32EX-DS<br>FX3UC-1PS-5V Output extension block<br>Output extension block OR FX2N-8EYR-ES/UL<br>FX2NC-16EYR-T-DSFX2NC-16EYT-DSS Interface converter FX2N-8EX FX2N-16EYR FX2N-8EYT-ESS/ULFX2N-16EYR-ES/UL<br>FX2NC-32EX FX2NC- FX2NC-32EYT-DSS a FX2NC-CNV-IF Input/output extension block FX2N-16EYT-ESS/UL<br>16EYR-T FX3UC-1PS-5V FX2N-8ER-ES/UL FX2N-16EYS<br>a Analog es Positioning Network<br>FX0N-3A FX2N-1PG-E FX2N-32CCL<br> Special function block FX2N-2AD FX3U-1PG FX3U-16CCL-M [1]<br>FX3U-4AD FX2N-10PG FX3U-64CCL<br>FX2N-2DA FX2N-10GM FX3U-ENET<br>Analog FX3U-4DA FX2N-1RM-E-SET FX3U-32DP<br>FX2N-5A FX3U-20SSC-H FX3U-64DP-M<br>FX3UC-4AD FX2N-8AD FX2N-20GM FX3U-CAN<br>FX2NC-4DA FX3U-J1939<br>High-speed counter Temperature High-speed counter Communication<br>FX3UC-4AD FX2NC-1HC FX3U-4DA FX3U-20SSC-H FX3U-64CCL FX2N-2LC FX3U-4LC FX2N-4AD-PTFX2N-4AD-TC FX2N-1HCFX3U-2HC FX2N-232IF<br> Terminal block Battery PLC bus connector<br>TB-8EX-C FX3U-32BL FX2N-CNV-BC<br>TB-16EX-STB-16EX-CTB-8EY-S Extension cable FX0N-65EC FX2NC-100MPCB (1 m) Power supply cable<br>TB-lEXl TB-20-STB-20C FX0N-30EC (30 cm)FX0N-65EC (65 cm) FX2NC-100BPCB (1 m)<br>.0 .1 .2 .3 .4 .5 .6 .7<br>**----- End of picture text -----**<br>
9
System description
~~**1** a~~
## **FX series configuration**
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3 expansion adapter<br>**----- End of picture text -----**<br>
**==> picture [210 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G CPU module<br>+<br>FX3 extension module<br>FX3 expansion board<br>**----- End of picture text -----**<br>
## **Expansion adapter**
## **CPU module**
**==> picture [495 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-232ADP-MB FX3U-485ADP-MB FX3U-4AD-ADP FX3U-4AD-PNK-ADP FX3G-CNV-ADP FX3G-24M FX3G-40M<br>Communication Analog Temperature Interface adapter<br>FX3U-232ADP-MB FX3U-4AD-ADP FX3U-4AD-PT-ADP FX3G-CNV-ADP |_| FX3G main unit 14–60 I/O<br>FX3U-485ADP-MB FX3U-4DA-ADP FX3U-4AD-TC-ADP FX3G-14MR/ES AC D R FX3G-40MR/ES AC D R<br>T Network FX3U-3A-ADP FX3U-4AD-PTW-ADPFX3U-4AD-PNK-ADP FX3G-14MT/ESFX3G-14MT/ESS oo ACAC DD T1T2 FX3G-40MT/ESFX3G-40MT/ESS — ACAC DD T1T2<br>FX3U-ENET-ADP [1] FX3G-14MR/DS sss DC D R FX3G-40MR/DS as DC D R<br>FX3G-14MT/DS DC D T1 FX3G-40MT/DS DC D T1<br>1 Firmware version 2.00 or later. FX3G-14MT/DSS +4 DC D T2 FX3G-40MT/DSS ——- DC D T2<br>Expansion board FX3G-24MR/ES AC D R FX3G-60MR/ES AC D R<br>FX3G-24MT/ES oo AC D T1 FX3G-60MT/ES — AC D T1<br>a Communication Analog setpoint Analog Digital FX3G-24MT/ESSFX3G-24MR/DS oott DCAC DD T2R FX3G-60MT/ESSFX3G-60MR/DS CITT DCAC DD T2R<br>FX3G-232-BD FX3G-8AV-BD FX3G-2AD-BD FX3G-4EX-BD FX3G-24MT/DS HI DC D T1 FX3G-60MT/DS tt DC D T1<br>MITSUBISHI FX3G-422-BD FX3G-1DA-BD FX3G-2EYT-BD FX3G-24MT/DSS = DC D T2 FX3G-60MT/DSS =e DC D T2<br>FX3G-485-BD<br>AC AC power supply R Relay output<br>=- DC DC power supply T1 Transistor output (sink)<br>FX3G-232-BD = D DC input (sink/source) | T2 Transistor output (source)<br>**----- End of picture text -----**<br>
**==> picture [109 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Te FX3 expansion adapter<br>+<br>FX3 expansion board<br>**----- End of picture text -----**<br>
**==> picture [112 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3GE CPU module<br>FX3 extension module<br>**----- End of picture text -----**<br>
## **Expansion adapter**
**==> picture [47 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPU module<br>**----- End of picture text -----**<br>
**==> picture [466 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-4AD-ADP FX3U-4AD-PNK-ADP FX3U-232ADP-MB FX3U-485ADP-MB<br>Analog Temperature Communication<br>FX3U-4AD-ADP FX3U-4AD-PT-ADP FX3U-232ADP-MB<br>FX3U-4DA-ADP FX3U-4AD-TC-ADP FX3U-485ADP-MB<br>FX3U-3A-ADP FX3U-4AD-PTW-ADP FX3GE-40M<br>FX3U-4AD-PNK-ADP<br>|_| FX3GE main unit 24–40 I/O<br>FX3GE-24MR/ES AC D R FX3GE-40MR/ES AC D R<br>FX3GE-24MT/ES Fo AC D T1 FX3GE-40MT/ES ptt AC D T1<br>FX3GE-24MT/ESS |} AC D T2 FX3GE-40MT/ESS tt AC D T2<br>re FX3G-232-BDFX3G-422-BDFX3G-422-BD Communication FX3G-8AV-BD ee Analog setpoint FX3G-2AD-BDFX3G-1DA-BDFX3G-1DA-BD Analog |_|= ACD AC power supplyDC input (sink/source)<br>FX3G-485-BD R Relay output<br>7 T1 Transistor output (sink)<br>T2 Transistor output (source)<br>0 1 2 3 4 5 6 7<br>LOT<br>INPUTANALOG V1+ I1+ V2+ I2+ VI-<br>100MSD/RDERROPEN<br>10BASE-T/100BASE-TX<br>OUTPUTANALOG V+ I+ VI-<br>X16 X17 X20 X21 X22 X23 X24 X25 X26 X27<br>X11 Y12 X13 5Y14 Y15 Y16 Y17<br>020 121 222 323 424 525 626 727<br>10 11 12 13 14 15 16 17<br>10 11 12 13 14 15 16 17<br>**----- End of picture text -----**<br>
## **Expansion board**
**==> picture [206 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
re Communication ee Analog setpoint Analog<br>MITSUBISHI FX3G-8AV-BD<br>FX3G-232-BDFX3G-422-BDFX3G-422-BD FX3G-2AD-BDFX3G-1DA-BDFX3G-1DA-BD<br>FX3G-485-BD<br>FX3G-232-BD<br>**----- End of picture text -----**<br>
1 To program FX3GE, select FX3G as the PLC type.
10
System description
~~**1**~~
**==> picture [482 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extension module<br>| I/O extension module<br>Powered extension unit Unpowered extension block<br>Input/output extension unit Input extension block Output extension block<br>FX2N-32ER-ES/UL FX2N-8EX-ES/UL FX2N-8EYR-ES/UL<br>FX2N-32ET-ESS/UL FX2N-8EX-UA1/UL FX2N-8EYT-ESS/UL<br>FX2N-48ER-ES/UL FX2N-16EX-ES/UL FX2N-16EYR-ES/UL<br>FX2N-48ER-DS FX2N-16EYT-ESS/UL<br>FX2N-48ET-DSSFX2N-48ER-UA1/UL ro FX2N-8ER-ES/UL Input/output extension block FX2N-16EYS<br>FX2N-48ER FX2N-48ET-ESS/UL FX2N-8EX<br>- Power supply unit a Special function block<br>Analog Temperature Network<br>Power supply unit FX2N-2AD FX2N-2LC FX2N-32CCL<br>iN a FS FX3U-1PSU-5V = i) = FX3U-4AD FX3U-4LC FX3U-16CCL-M [1]<br>FX2N-2DA FX2N-4AD-TC FX3U-64CCL<br>FX3U-4DA FX2N-4AD-PT FX3U-ENET<br>FX2N-5A FX3U-32DP<br>FX2N-8AD FX3U-CAN<br>FX3U-1PSU-5V FX3U-4DA FX3U-J1939<br>Option<br> Memory cassette Display module Extension cable PLC bus connector Battery<br>FX3G-EEPROM-32L FX3G-5DM FX0N-30EC (30 cm) FX2N-CNV-BC FX3U-32BL<br>FX0N-65EC (65 cm)<br>= FX3G-EEPROM-32L FX3G-5DM FX0N-65EC<br>**----- End of picture text -----**<br>
**==> picture [481 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extension module<br>| I/O extension module<br>Powered extension unit Unpowered extension block<br>Input/output extension unit Input extension block Output extension block<br>FX2N-32ER-ES/UL FX2N-8EX-ES/UL FX2N-8EYR-ES/UL<br>FX2N-32ET-ESS/UL FX2N-8EX-UA1/UL FX2N-8EYT-ESS/UL<br>FX2N-48ER-ES/UL FX2N-16EX-ES/UL FX2N-16EYR-ES/UL<br>FX2N-48ER-DS FX2N-16EYT-ESS/UL<br>FX2N-48ET-DSS ro Input/output extension block FX2N-16EYS<br>FX2N-48ER-UA1/UL FX2N-8ER-ES/UL<br>FX2N-48ER FX2N-48ET-ESS/UL FX2N-8EX<br>7 Power supply unit a Special function block<br>Analog Temperature Network<br>Power supply unit FX2N-2AD FX2N-2LC FX2N-32CCL<br>FX3U-1PSU-5V FX3U-4AD FX3U-4LC FX3U-16CCL-M [1]<br>FX2N-2DA FX2N-4AD-TC FX3U-64CCL<br>FX3U-4DA FX2N-4AD-PT FX3U-ENET<br>FX2N-5A FX3U-32DP<br>FX2N-8AD FX3U-CAN<br>FX3U-1PSU-5V FX3U-4DA FX3U-J1939<br>Option<br>iTsuBIsH! a Memory cassette MITSUBISHI “ a Display module ee P| Extension cable 7 PLC bus connector Battery<br>FX3G-EEPROM-32L FX3G-5DM FX0N-30EC (30 cm) FX2N-CNV-BC FX3U-32BL<br>FX0N-65EC (65 cm)<br>FX3G-EEPROM-32L FX3G-5DM FX0N-65EC<br>**----- End of picture text -----**<br>
11
System description
~~**1** 7~~
## **FX series configuration**
**==> picture [119 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3 expansion adapter<br>FX3GC CPU module<br>FX3 extension module<br>LS ~—<br>**----- End of picture text -----**<br>
## **Expansion adapter**
## **CPU module**
**==> picture [480 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3GC-32M<br>FX3U-ENET-ADP FX3U-232ADP-MB FX3U-485ADP-MB FX3U-4AD-ADP FX3U-4AD-PNK-ADP 7 FX3GC main unit 32 I/O<br>Network Communication Analog Temperature FX3GC-32MT/D DC D T1<br>Pe FX3U-ENET-ADP [1] Pe FX3U-232ADP-MB FX3U-4AD-ADP Pe lel FX3U-4AD-PT-ADP FX3GC-32MT/DSS PT DC D T2<br>FX3U-485ADP-MB FX3U-4DA-ADP FX3U-4AD-TC-ADP<br>FX3U-3A-ADP FX3U-4AD-PTW-ADP<br>FX3U-4AD-PNK-ADP |_||_| DCD DC power supplyDC input (sink/source) || T1T2 Transistor output (sink)Transistor output (source)<br>**----- End of picture text -----**<br>
1 Firmware version 2.00 or later.
## **Option**
## **Connecting to terminal block**
TB-EX-CAB-1M (1 m) TB-EX-CAB-3M (3 m) TB-EX-CAB-5M (5 m) TB-EY-CAB-1M (1 m)
**==> picture [74 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3 expansion adapter<br>FX3S CPU module<br>**----- End of picture text -----**<br>
**==> picture [42 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3 expansion board<br>**----- End of picture text -----**<br>
**Expansion adapter**
**==> picture [420 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-ENET-ADP FX3U-232ADP-MB FX3U-4AD-ADP FX3U-4AD-PNK-ADP FX3S-CNV-ADP<br>rc Network em Communication rc Analog tem Temperature Interface adapter<br>FX3U-ENET-ADP FX3U-232ADP-MB FX3U-4AD-ADP FX3U-4AD-PT-ADP FX3S-CNV-ADP<br>FX3U-485ADP-MB FX3U-4DA-ADP FX3U-4AD-TC-ADP<br>FX3U-3A-ADP FX3U-4AD-PTW-ADP<br>FX3U-4AD-PNK-ADP<br>**----- End of picture text -----**<br>
## **Expansion board**
**==> picture [288 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Frc Communication clmmC Analog setpoint QC“ Analog (ite Digital<br>FX3G-232-BD FX3G-8AV-BD FX3G-2AD-BD FX3G-4EX-BD<br>FX3G-422-BD FX3G-1DA-BD FX3G-2EYT-BD<br>FX3G-485-BD<br>FX3G-232-BD<br>**----- End of picture text -----**<br>
12
System description
~~**1**~~
**==> picture [479 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extension module<br>a I/O extension block<br>Unpowered extension block<br>Input extension block<br>FX2NC-16EX-T-DSFX2NC-16EX-DS Power supply unit FX2N-8EX-ES/UL Input extension block FX2N-8EYR-ES/UL Output extension block<br>FX2NC-32EX-DS FX3UC-1PS-5V FX2N-8EX-UA1/UL FX2N-8EYT-ESS/UL<br>Output extension block OR FX2N-16EX-ES/UL FX2N-16EYR-ES/ULFX2N-16EYT-ESS/UL<br>FX2NC-16EYR-T-DS Interface converter Input/output extension block FX2N-16EYS<br>FX2NC-32EX 16EYR-TFX2NC- FX2NC-16EYT-DSSFX2NC-32EYT-DSS FX3UC-1PS-5V FX2NC-CNV-IF FX2N-8EX FX2N-8ER-ES/UL<br>a Special function block<br>Analog Analog Temperature Network<br>FX3UC-4AD FX2N-2AD FX2N-2LC FX2N-32CCL<br>FX2NC-4DA FX3U-4AD FX3U-4LC FX3U-16CCL-M [1]<br>FX2N-2DA FX2N-4AD-TC FX3U-64CCL<br>FX3U-4DA FX2N-4AD-PT FX3U-ENET<br>FX2N-5A FX3U-32DP<br>FX2N-8AD FX3U-CAN<br>FX3UC-4AD FX3U-4DA FX3U-J1939<br> Terminal block Battery PLC bus connector<br>TB-8EX-C FX3U-32BL FX2N-CNV-BC<br>TB-lEXl TB-16EX-STB-16EX-CTB-8EY-STB-20-S FX0N-30EC (30 cm) Extension cable FX0N-65EC FX2NC-100MPCB (1 m)FX2NC-100BP Power supply cable CB (1 m)<br>= TB-20C FX0N-65EC (65 cm) :<br>.0 .1 .2 .3 .4 .5 .6 .7<br>**----- End of picture text -----**<br>
**==> picture [236 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPU module<br><N<br>a<br>FX3S-10M<br>| FX3S main unit 10–30 I/O<br>FX3S-10MR/ES AC D R FX3S-20MR/ES AC D R AC AC power supply<br>FX3S-10MT/ES =| AC D T1 FX3S-20MT/ES =] AC D T1 F D DC input (sink/source)<br>FX3S-10MT/ESS AC D T2 FX3S-20MT/ESS AC D T2 R Relay output<br>En Pt = T1 Transistor output (sink)<br>FX3S-14MR/ESFX3S-14MT/ES Pty ACAC DD T1R FX3S-30MR/ESFX3S-30MT/ES Pry ACAC DD T1R = T2 Transistor output (source)<br>FX3S-14MT/ESS = AC D T2 FX3S-30MT/ESS — AC D T2<br>Option<br>| Memory cassette<br>FX3G-EEPROM-32L<br>FX3G-EEPROM-32L<br>**----- End of picture text -----**<br>
13
System description
~~**1**~~
**==> picture [559 x 629] intentionally omitted <==**
**----- Start of picture text -----**<br>
- FX5 expansion adapter<br>FX series configuration<br>FX5U CPU module<br>FX5 extension module<br>Expansion (Extension cable type)<br>adapter<br>Max.6 Connector<br>modules<br>> conversion module<br>|<br>FX5 expansion board<br>* Up to 12 modules can be directly con-<br>Extension nected to CPU module. Up to 16 modules<br>module can be connected by connecting a pow-<br>ered I/O module or an extension power<br>modules*Max.16 supply module. Extension power supply modules and<br>FX5 extension module connector conversion modules are not<br>included in the number of connected<br>o>. (Extension connector type) modules.<br>Expansion adapter CPU module<br>Max.<br>2<br>modules<br>FX5-232ADP Expansion boards<br>Communication<br>FX5-232ADP For RS232C communication uc Max. =z<br>FX5-485ADP For RS485 communication 1 FX5U-32M<br>module<br>FX5-422-BD-GOT e<br>Communication<br>. ee FX5U-32MR/ES — AC D2 R<br>Max. FX5-232ADP For RS232C communication FX5U-32MT/ES AC D2 T1<br>4 FX5-485ADP For RS485 communication FX5U-32MT/ESS AC D2 T2<br>modules FX5-422-BD-GOT For RS422 communication FX5U-32MR/DS DC D2 R<br>(For GOT connection) FX5U-32MT/DS DC D2 T1<br>FX5U-32MT/DSS DC D2 T2<br>FX5-4AD-ADP ie Input: 16 points/Output: 16 points =<br>Peripheral device<br>PS Analog<br>FX5-4AD-ADP For analog input<br>FX5-4DA-ADP For analog output HMI<br>GOT2000, GOT1000 FX5U-64MR/ES AC D2 R<br>FX5U-64MT/ES AC D2 T1<br>FX5U-64MT/ESS AC D2 T2<br>FX5U-64MR/DS DC D2 R<br>Option FX5U-64MT/DSFX5U-64MT/DSS DCDC D2D2 T1T2<br>Input: 32 points/Output: 32 points<br>Pll Battery SD memory card es Engineering tool<br>FX3U-32BL NZ1MEM-2GBSD (2 GB) GX Works3 FX5U-80MR/ES —_ AC D2 R<br>NZ1MEM-4GBSD (4 GB) FX5U-80MT/ES AC D2 T1<br>FX5U-80MT/ESS AC D2 T2<br>FX5U-80MR/DS DC D2 R<br>FX5U-80MT/DS DC D2 T1<br>FX5U-80MT/DSS DC D2 T2<br>Input: 40 points/Output: 40 points<br>Power supply cable Extended extension cable<br> CPU module power supply cable<br>FX2NC-100MPCB (1 m)<br>(attached to CPU module)<br> Power supply cable AC AC power supply T1 Transistor output (sink)<br>es FX2NC-100BPCB (1 m)(attached to FX5UC-mMT/D) «= Foal FX5-65EC FX5-CNV-BC DCD2 DC power supplyDC input (sink/source) T2R Transistor output (source)Relay output<br>. Power supply crossover cable . Extended extension cable Connector conversion adapter<br>FX2NC-10BPCB1 (0.1 m) FX5-30EC [2] FX5-CNV-BC<br>(attached to FX5-CmEX/D, FX5-C32ET/D) FX5-65EC [2]<br>Connector connection Cable connection<br>**----- End of picture text -----**<br>
- 1 When adding the extension module, it is necessary to connect it to the front stage of extension module in case of a shortage of internal power supply in CPU module.
- 2 Attach when connecting an extension cable type module to a distant location or when making two-tier connections. The connector conversion adapter (FX5-CNV-BC) is required when connected with an input/output module (extension cable type), high-speed pulse input/output module, or an intelligent function module. When using also the bus conversion module in the same system, connect the FX5 extension power supply module or the powered I/O module right after the extended extension cable.
- 3 Can be connected only to the AC power type system.
- 4 Can be connected only to the DC power type system.
14
System description
~~**1**~~
## **Extension module**
**==> picture [484 x 465] intentionally omitted <==**
**----- Start of picture text -----**<br>
I/O module a Intelligent function module | Extension power supply<br>module<br>Powered I/O module Input/output module<br>Simple motion<br>FX5-40SSC-S<br>FX5-80SSC-S<br>FX5-40SSC-S<br>FX5-32-ER/ES FX5-16EX/ES FX5-16EYT/ES<br>Powered I/O module Input module Output module FX5-1PSU-5V<br>FX5-32ER/ES FX5-8EX/ES FX5-8EYR/ES<br>FX5-32ET/ES FX5-16EX/ES FX5-8EYT/ES Extension power supply<br>FX5-32ET/ESS FX5-8EYT/ESS module<br>FX5-32ER/DS High-speed pulse FX5-16EYR/ES "Nie 3) CCLink IE Glew po<br>FX5-32ET/DS input/output module FX5-16EYT/ES Network FX5-1PSU-5V [3]<br>FX5-32ET/DSS FX5-16EYT/ESS FX5-CCLIEF<br>FX5-16ET/ES-H<br>FX5-16ET/ESS-H<br>FX5-CCLIEF<br>Extension module Extension module Bus conversion<br>(extension cable type) (extension connector type) module FX3 extension module<br>| Connector a I/O module a Intelligent function module<br>conversion module<br>Analog<br>a Input module Output module Bus conversion e FX3U-4AD For input s<br>FX5-C16EX/D FX5-C16EYT/D module FX3U-4D A For output<br>FX5-C16EX/DS FX5-C16EYT/DSS<br>FX5-C32EX/D FX5-C32EYT/D FX5-CNV-BUSC Temperature control<br>FX5-C32EX/DS FX5-C32EYT/DSS FX3U-4LC Temperature control<br>FX5-C16EX/DS Positioning<br>c Input/output module a - — FX3U-1PG ___ For pulse output<br>FX5-CNV-IF a P| FX5-C32ET/D es High speed counter<br>FX5-C32ET/DSS FX3U-2HC For high-speed input<br>Connector conversion<br>FX5-CNV-IF module - Extension power supply module |! FX3U-64CCL Communication/Network CC-Link slave<br>FX3U-16CCL-M CC-Link master<br>FX3U-128ASL-M AnyWireASLINK master<br>FX5-CNV-BUS<br>Extension power supply module For th e module requiring parameter in FX3 extension<br>FX5-C1PS-5V [14] Bus conversion module, parameter settings by program are necessary.<br>es — module a When connecting the FX3 extension module, the bus<br>FX5-CNV-BUS speed for FX3 applies for access.<br>a Extension power supply module<br>Extension power supply module<br>FX3U-1PSU-5V [1]<br> - FX5-1PSU-5V<br>**----- End of picture text -----**<br>
15
System description
~~**1** s~~ F-X5UC **Expansion adapter**
## **FX series configuration**
**==> picture [353 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
~ FX5 expansion adapter Connector conversion module<br>or extension power supply module<br>FX5UC CPU module<br>~ FX5 extension module<br>(Extension connector type)<br>Expansion FX5 extension module<br>adapter — (Extension cable type)<br>Max.6<br>modules<br>* Up to 12 modules can be directly con-<br>>> =<br>nected to CPU module. Up to 16 modules<br>can be connected by connecting a pow-<br>ered I/O module or an extension power<br>supply module.<br>Extension Extension power supply modules and<br>module connector conversion modules are not<br>Max.16 included in the number of connected<br>modules* modules.<br>**----- End of picture text -----**<br>
## **Extension module**
## **CPU module**
**(extension connector type)**
**==> picture [463 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
I/O module<br>Max.<br>2<br>modules FX5UC-32MT/D DC D1 T1<br>FX5UC-32MT/DSS === DC D2 T2<br>Input: 16 points/Output: 16 points<br>FX5-232ADP<br>Communication<br>FX5-232ADP For RS232C communication FX5-C16EX/DS<br>FX5-485ADP For RS485 communication FX5UC-64MT/D DC D1 T1<br>FX5UC-64MT/DSS <== DC D2 T2<br>Input: 32 points/Output: 32 points es Input module<br>| FX5-C16EX/D<br>Max. FX5-C16EX/DS<br>4 FX5-C32EX/D<br>modules FX5-C32EX/DS<br>FX5UC-32MT/DSS Output module<br>FX5UC-96MT/D DC D1 T1 FX5-C16EYT/D<br>FX5-4AD-ADP FX5UC-96MT/DSS DC D2 T2 FX5-C16EYT/DSS<br>Input: 48 points/Output: 48 points FX5-C32EYT/D<br>FX5-C32EYT/DSS<br>Analog<br>es FX5-4AD-ADP For analog input — I/O module<br>FX5-4DA-ADP For analog output FX5-C32ET/D<br>FX5-C32ET/DSS<br>DC DC power supply T1 Transistor output (sink)<br>D1 DC input (sink) T2 Transistor output (source)<br>D2 DC input (sink/source)<br>Connector connection Cable connection<br>**----- End of picture text -----**<br>
## **Peripheral device**
**==> picture [91 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
|) HMI<br>GOT2000, GOT1000<br>**----- End of picture text -----**<br>
**==> picture [27 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Option<br>**----- End of picture text -----**<br>
**==> picture [466 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
Battery I/O cable Terminal block Power supply cable Extended extension cable<br>FX3U-32BL SS CPU module<br>power supply cable<br>SD memory card FX2NC-100MPCB (1 m)(attached to CPU module) FX5-65EC<br>NZ1MEM-2GBSD (2 GB)NZ1MEM-4GBSD (4 GB) Power supply cable | Extended extension cable<br> For Terminal blocks TB-lEXl FX2NC-100BPCB (1 m)(attached to FX5UC-mMT/D) FX5-30EC FX5-65EC [3][3]<br>— Engineering tool TB-EX-CAB-1M (1 m) TB-8EX-C TB-8EY-S<br>GX Works3 TB-EX-CAB-3M (3 m) TB-16EX-S TB-20-S<br>TB-EX-CAB-5M (5 m) TB-16EX-C TB-20C<br>TB-EY-CAB-1M (1 m)<br>FX5-CNV-BC<br> Connector conversion<br>adapter<br>FX5-CNV-BC<br>.0 .1 .2 .3 .4 .5 .6 .7<br>**----- End of picture text -----**<br>
- 1 When adding the extension module, it is necessary to connect it to the front stage of extension module in case of a shortage of internal power supply in CPU module.
- 2 Next-stage extension connector of an extension power supply module can be used only for either connector connection or cable connection. In case of connector connection, an extension connector type module can be connected.
- 3 Attach when connecting an extension cable type module to a distant location or when making two-tier connections. The connector conversion adapter (FX5-CNV-BC) is required when connected with an input/output module (extension cable type) or an intelligent function module. When using also the bus conversion module in the same system, connect the powered I/O module right after the extended extension cable.
16
System description
~~**1**~~
## **Extension module Extension module (extension connector type) (extension cable type)**
**==> picture [463 x 422] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extension power supply module |_| I/O module |_| Intelligent function module<br>Powered I/O module Input/output module<br>Extension power supply module<br>FX5-C1PS-5V [12]<br>FX5-40SSC-S<br>FX5-32-ER/ES FX5-16EX/ES FX5-16EYT/ES<br>| Simple motion<br>FX5-40SSC-S<br>OR |<br>Powered I/O module Input module Output module<br> Connector conversion module<br>FX5-32ER/DS es FX5-8EX/ES FX5-8EYR/ES ;<br>FX5-32ET/DS FX5-16EX/ES FX5-8EYT/ES<br>FX5-32ET/DSS FX5-8EYT/ESS<br>High-speed pulse FX5-16EYR/ES<br>input/output module FX5-16EYT/ES<br>FX5-16EYT/ESS<br>FX5-16ET/ES-H<br>Connector conversion module FX5-16ET/ESS-H<br>FX5-CNV-IFC FX5-CCLIEF<br>CC-Link IE Geta<br>es Network<br>FX5-CCLIEF<br>Bus conversion module FX3 extension module<br>g |_| Intelligent function module<br>Analog Temperature control<br>Bus conversion module<br>FX3U-4AD For input FX3U-4LC Temperature control<br>FX5-CNV-BUS FX3U-4DA For output<br>ai as es High-speed counter<br>FX5-CNV-BUS es Positioning FX3U-2HC For high-speed input<br>FX3U-1PG For pulse output<br>es Communication/Network<br>FX3U-64CCL CC-Link slave<br>FX3U-16CCL-M CC-Link master<br>FX3U-128ASL-M AnyWireASLINK master<br>Re Bus conversion module<br>FX5-CNV-BUSC<br>For the module requiring parameter in FX3 extension module, parameter settings by program are<br>necessary. When connecting the FX3 extension module, the bus speed for FX3 applies for access.<br>**----- End of picture text -----**<br>
17
System description
~~**1**~~
## **Calculation of the power consumption**
The power consumption figures on the 5 V DC bus for the special function modules are shown in the specifications tables on the following pages.
The maximum permissible currents on the 5 V DC and 24 V DC bus are shown in the table below.
**==> picture [163 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
Max. current<br>Modules<br>5 V bus 24 V bus<br>FX3G-14/24Mm-ES(ESS) — 400 mA<br>FX3G-40/60Mm-ES(ESS) — 400 mA<br>FX3U-16/32Mm-ES(ESS) 500 mA 400 mA<br>FX3U-48–128Mm-ES(ESS) 500 mA 600 mA<br>FX3UC-16MT/D(DSS) 600 mA —<br>FX3UC-32MT/D(DSS) 560 mA —<br>FX3UC-64MT/D(DSS) 480 mA —<br>FX3UC-96MT/D(DSS) 400 mA —<br>FX5U-32Mm/Em 900 mA 480 mA<br>FX5U-64Mm/Em 1100 mA 740 mA<br>FX5U-80Mm/Em 1100 mA 770 mA<br>FX5UC-32/64/96MT/m 720 mA 500 mA<br>**----- End of picture text -----**<br>
The residual currents for the 24 V DC service voltage at different input/output configurations are shown in the tables on the right.
Max. residual current values (in mA) for FX3U-16Mm/Emm through FX3U-32Mm/Emm for the permissible configuration
**==> picture [338 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
40 25<br>32 100 50 0<br>Number of 24 175 125 75 25<br>additional<br>outputs 16 250 200 150 100 50 0<br>8 325 275 225 175 125 75 25<br>0 400 350 300 250 200 150 100 50 0<br>0 8 16 24 32 40 48 56 64<br>Number of additional inputs<br>**----- End of picture text -----**<br>
Max. residual current values (in mA) for FX3U-48Mm/Emm through FX3U-128Mm/Emm for the permissible configuration
**==> picture [339 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
64 0<br>56 75 25<br>48 150 100 50 0<br>40 225 175 125 75 25<br>Number of<br>additional 32 300 250 200 150 100 50 0<br>outputs 24 375 325 275 225 175 125 75 25<br>16 450 400 350 300 250 200 150 100 50 0<br>8 525 475 425 375 325 275 225 175 125 75 25<br>0 600 550 500 450 400 350 300 250 200 150 100 50 0<br>0 8 16 24 32 40 48 56 64 72 80 88 96<br>Number of additional inputs<br>**----- End of picture text -----**<br>
A maximum of 256 I/Os are possible for FX3U/ FX3UC/FX5U/FX5UC (128 I/Os for FX3G/FX3GC).
## **Sample calculations**
The tables below and on the right show different examples for sample power calculation for a PLC system.
The current values for the special function modules can be found in the specifications on the following pages. Comparison with the current value tables show that the calculated figures for the 5 V bus lie within the allowable ranges.
**==> picture [337 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
24 V DC calculation 5 V DC calculation<br>Module No.<br>Current/module Calculation Current/module Total current<br>FX3U-80MR/ES 1 600 mA +600 mA +500 mA +500 mA<br>FX3U-4AD 2 90 mA -180 mA 110 mA -220 mA<br>FX3U-4DA 2 160 mA -320 mA 120 mA -240 mA<br>FX3U-ENET 1 240 mA -240 mA — —<br>-140 mA !!! 500–460 mA<br>Result: 40 mA (OK !)<br>**----- End of picture text -----**<br>
An external 24 V power supply has to be added in the example above.
In the example below all units can be supplied sufficiently with the internal 24 V power supply.
**==> picture [512 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
Number of I/Os 24 V DC calculation 5 V DC calculation<br>Module No.<br>X Y X/Y Total [1] Total current [2] Current/module Total current<br>FX3U-48MR/ES 1 24 24 — 500 mA +500 mA<br>FX2N-16EYR-ES/UL 1 — 16 — X = 8 — 0 mA<br>Y = 24 +325 mA<br>FX2N-8EX-ES/UL 1 8 — — R — 0 mA<br>FX2N-8EYR-ES/UL 1 — 8 — — 0 mA<br>FX3U-4AD-PT-ADP 1 — — — -50 mA 30 mA -15 mA<br>+275 mA (OK!) +485 mA (OK!)<br>FX2N-32ER-ES/UL 1 16 16 — +150 mA residual current 690 mA +690 mA<br>FX2N-16EX-ES/UL 1 16 — — X = 16 Y = 0 for extension unit FX2N-32ER-ES/UL — 0 mA<br>FX2N-10PG 1 — — 8 R 0 mA 120 mA -120 mA<br>FX2N-32CCL 1 — — 8 -50 mA 130 mA -130 mA<br>Result : 64 + 64 +16= 144 ! (< 256) OK! +100 mA (OK!) +440 mA (OK!)<br>**----- End of picture text -----**<br>
Total no. of I/Os which are connected to a base unit to calculate the max. residual current values (see tables) See tables above (max. residual current values)
18
Special functions
~~**1**~~
## **MELSEC iQ-F – FX5 advanced built-in functions**
## ~~**High-speed system bus communication**~~
¨ **FX3 series** þ **FX5 iQ-F series**
High-speed system bus communication at 1.5 K words/ ms (approximately 150 times faster compared with FX3U) together with a high-speed CPU allows MELSEC iQ-F to output maximum performance even when heavy data communication intelligent function modules are used.
**==> picture [265 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5 expansion FX5 CPU module FX5 extension module<br>adapter<br>High-speed<br>system bus<br>\| -A @Ee|<br>**----- End of picture text -----**<br>
## ~~**Built-in Ethernet port**~~
¨ **FX3 series** þ **FX5 iQ-F series**
The built-in Ethernet communication port can handle communication of up to 8 connections on the network and supports multiple connections with personal computers and other devices.
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ethernet<br>**----- End of picture text -----**<br>
## **PLC to PLC communication**
Directly connect to other PLCs.
## **SLMP communication**
**==> picture [490 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
HUB or router<br>PCs and other devices can communicate with the CPU<br>module via the open protocol SLMP (SeamLess Message PC<br>Protocol).<br>Communications through SLMP<br>=. &<br>**----- End of picture text -----**<br>
## **Remote maintenance**
Secure remote connectivity to the PLC is possible via a VPN tunnel.
PC **VPN tunnel** VPN router VPN router ~~"_~~ @ ~~-~~ &
19
Special functions
~~**1**~~
## ~~**Built-in analog inputs/outputs (with alarm output)**~~
**==> picture [508 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
¨ FX3 series þ FX5 iQ-F series<br>The FX5U is equipped with two 12-bit analog inputs and<br>one analog output. Setup is done with parameter settings, Ethernet<br>FX5U<br>no programming required. Value shifting, scaling and alarm<br>output can also be set easily with parameters.<br>GOT<br>= Analog output | [o] i [n][s] 08,= Fo<br>Inverter LJ<br>Inverter control using analog output<br>a Built-in RS485 port (with Modbus® function)<br>¨ FX3 series þ FX5 iQ-F series<br>**----- End of picture text -----**<br>
With the built-in RS485 port FX5U/FX5UC can connect to serial devices up to 50 m away. Dedicated inverter communication instructions allow to control up to 16 Mitsubishi inverters. Additionally Modbus® is supported and enables the FX5U/FX5UC to connect to up to 32 devices such as PLCs, sensors and temperature controllers.
**==> picture [235 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5U/FX5UC (master)<br>Max. 50 m<br>RS485 Max. 16 modules<br>= =<br>= 6 B =<br>=6 Mitsubishi inverter<br>FX5U/FX5UC (master)<br>Max. 50 m<br>Modbus® (RS485) Max. 32 stations<br>C<br>ww a.<br>Modbus® devices<br>(Inverter, temperature<br>a controllers, etc.) LI<br>**----- End of picture text -----**<br>
**==> picture [81 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inverter communication<br>**----- End of picture text -----**<br>
Modbus® communication
## ~~**Built-in SD card slot**~~
¨ **FX3 series** þ **FX5 iQ-F series**
The built-in SD card slot of FX5 can be used to simplify the startup of mass production equipment and also store logging data.
**==> picture [176 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office<br>ti<br>nes<br>Production site<br>**----- End of picture text -----**<br>
Mass-production of equipment using SD memory card
20
Special functions
~~**1**~~
## ~~**Data logging**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
To meet the future needs of Industry 4.0, the FX5 offers comprehensive data logging functionality as standard, with all data from energy consumption to product throughput captured, at a specified interval or random timing, on a standard SD card for further analysis.
Continuous logging at a maximum speed of 10-ms cycles is possible. In addition, an internal buffer capacity can be set to store the collected results temporarily.
**==> picture [224 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data<br>logging<br>Logging<br>setting<br>Data can be visually displayed and efficiently<br>analyzed by using GX LogViewer.<br>SD memory<br>card<br>**----- End of picture text -----**<br>
## ~~**Security functions**~~
¨ **FX3 series** þ **FX5 iQ-F series**
To protect your intellectual property the FX5 comes with several built-in security functions such as:
z Remote password/security key
- z Privilege based program access
- z Program on SD card with copy protection password
**==> picture [297 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
Program is<br>executed<br>Key A Key A Key A 7 Key A o<br>Li e Ll Program cannot<br>be executed<br>[ED = i<br>Key A 7 No key or key B x<br>Security key function<br>Copy<br>Unauthorized copy<br>**----- End of picture text -----**<br>
## ~~**Intuitive programming environment**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
## **GX Works3**
- z Easy programming by drag and drop
- z Reduced development time with module function blocks
- z Parameter set-up for a variety of functions
**==> picture [172 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
Simply drag & drop<br>when adding<br>a module<br>Drag & Drop<br>**----- End of picture text -----**<br>
Graphical system design
**==> picture [165 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Double click<br>Work window for<br>related parameters<br>**----- End of picture text -----**<br>
Auto-generation of module parameters
21
Special functions
~~**1**~~
## ~~**Battery-less and maintenance-free**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
MELSEC iQ-F series holds programs and devices in nonvolatile memory such as flash ROM and does not require a battery.
Note: It is possible to increase the capacity of held devices by using an optional battery.
## ~~**Built-in positioning (200 kpps, 4 axes built in) + Positioning 2 axes (200 kpps, 2 axes)**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
## **Positioning that support 20 μs high-speed startup**
FX5 features powerful positioning functionality with 8-channel high-speed pulse inputs and 4-axis pulse outputs. In addition to the existing interrupt stop operation and variable speed operation, new functions have been added and made even easier to use. Furthermore, up to four highspeed pulse I/O modules can be connected for affordable multi-axis control.
**==> picture [284 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
Max. 8 ch 200 kHz* High-speed pulse I/O<br>module FX5-16ET/Em-H<br>Max. 4<br>Rotary encoder<br>* FX5U-32M : 6 ch 200 kHz + 2 ch 10 kHz<br>FX5UC-32M : 6 ch 200 kHz + 2 ch 10 kHz<br>200 kpps<br>200 kpps<br>Servo amplifier Servo amplifier CPU module 4 axes<br>|<br>FX5-16ET/E m -H<br>Total 2 axes x 4 modules = 8 axes<br>__|<br>6 axes<br>Built-in positioning Positioning Total of 12 axes of<br>4 axes 2 axes control is possible!<br>FX5 CPU module FX5-16ET/E m -H<br>EE° - > 2<br>Further<br>**----- End of picture text -----**<br>
## Packaging machine example with built-in positioning
**==> picture [286 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
In case of pulse train + sign Simple Linear Interpolation<br>Pulse output (2-Axis simultaneous start)<br>Target position (x, y)<br>y<br>ON (Forward rotation) OFF (Reverse rotation)<br>_ _ Rotational direction Start point aa x<br>**----- End of picture text -----**<br>
22
Special functions
~~**1**~~
## ~~**Simple motion modules (4-axis/8-axis control modules)**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
## **Positioning control with SSCNETIII/H**
FX5-40SSC-S/FX5-80SSC-S are equipped with 4-axis/8-axis positioning functions compatible with SSCNETIII/H. Positioning control is easily performed with a sequence program starting positioning data of a point table.
To respond to extensive applications, various positioning controls are available: Linear interpolation, 2-axis circular interpolation, fixed-pitch feed, and continuous trajectory controls, etc.
- z Linear interpolation
- z Circular interpolation
**==> picture [206 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-40SSC-S/<br>FX5-80SSC-S<br>3<br>1<br>2<br>4<br>a<br>1. X axis<br>2. Y axis<br>3. Z axis<br>**----- End of picture text -----**<br>
4. Paint
- z Continuous trajectory control
- z S-curve acceleration/deceleration
## ~~**Basic positioning control**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
Positioning control is easily performed with a sequence program starting positioning data of a point table. To respond to extensive applications, various positioning controls are available: Linear interpolation, 2-axis circular interpolation, fixed-pitch feed, and continuous trajectory controls, etc.
**==> picture [271 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPU module Simple Motion module<br>Sequence program Positioning data<br>Axis 1 Axis 2 Axis 3 Axis 4<br>H f_ \f _ \f<br>No. Operation pattern Control system Acceleration time no. Deceleration time no. Positioning address Command speed<br>1 1: CONT 01h: ABS Linear 1 0: 1000 0: 1000 200000.0 μm 20000.00 mm/min<br><Positioning Comment><br>2 0: END 01h: ABS Linear 1 0: 1000 0: 1000 -200000.0 μm 10000.00 mm/min<br><Positioning Comment><br>**----- End of picture text -----**<br>
23
Special functions
~~**1**~~
## ~~**Advanced motion control**~~
## ¨ **FX3 series** þ **FX5 iQ-F series**
## **Making Simple Motion with compactly packed extra functions**
Similar to positioning modules, simple motion modules are capable of a wide range of high-precision control such as positional control, advanced synchronous control, cam control, and speed-torque control with setup being done easily by parameters and programming.
## **Synchronous control**
In addition to synchronous control that replaces physical machine mechanisms such as gears, shaft, transmission and cam with software, functions such as cam control, clutch and cam auto-generation are easily realized. Since synchronous control can be started and stopped for each axis, programs can contain both synchronous control axes and positioning control axes.
Up to four axes can be synchronized to the synchronous encoder axis, enabling use with a variety of systems.
- z Use synchronous control and cam control to build a system perfect for your equipment.
- z Register up to 64 types of cam patterns to respond to any type of packaging needs.
- z Perform continuous operation without stopping the workpiece operation.
**==> picture [245 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5U FX5-40SSC-S<br>RS485 QO SSCNETIN/H Axis 2 a<br>Axis 4<br>Inverter<br>MR-J4 series awe: ‘fm Axis 1<br>Axis 3<br>**----- End of picture text -----**<br>
Packaging machine with Simple Motion
## **Mark detection function**
The cutter axis deviation can be compensated by detecting a mark on the workpiece so the workpiece can be cut at a constant position.
**==> picture [67 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mark detection<br>Cam<br>auto-generation<br>**----- End of picture text -----**<br>
Rotary cutter control with mark detection and cam data
## **Cam data auto-generation**
Easily program and automatically generate difficult cam data for rotary cutters just by inputting the sheet length, synchronization width, and cam resolution, etc.
**==> picture [247 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cam data Synchronous<br>~~<br>axis length<br>Sheet feeding<br>(circumference)<br>User-created GOT screen<br>Synchronization width<br>Sheet length<br>Cam axis<br>(Synchronized axis)<br>Speed<br>Sheet feeding speed<br>Parameter settings,<br>including items like<br>sheet length, etc.<br>Synchronization width<br>Stroke ratio<br>**----- End of picture text -----**<br>
24
Special functions
~~**1**~~
## **MELSEC-F – FX3 built-in functions**
## ~~**FX control solutions**~~
## þ **FX3 series** ¨ **FX5 iQ-F series**
## **Positioning**
Built-in high-speed pulse outputs and special instructions enable the FX series main units to control up to 3 independent axes of servo motion from the main unit itself at up to 100 kHz. Connecting two high-speed output special adapters to the FX3U allows for up to 4 axes of control at up to 200 kHz. *
With special function blocks, interpolated and networked servo control solutions are also available.
## **Analog control**
The FX series features easy analog to digital and digital to analog conversion for all models using expansion boards, special adapters or special function blocks.
## **Information exchange**
Information can be sent to a higher level PC that constantly monitors production, raising the reliability and overall efficiency of the system.
## **High-speed control**
With 6 to 8 high speed counters on each model, the FX series is perfectly suited for applications in need of pulsecatch functions, closed-loop feedback processing or highspeed sensor use.
## **Open Field networks**
Among the networks supported by the FX series are CC-Link and Ethernet, Modbus® and Profibus, providing both a wide selection for new solutions and an interface into existing networks.
**==> picture [177 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3 series<br>Transistor-type output<br>Pulse output<br>ON (Forward rotation) OFF (Reverse rotation)<br>Direction<br>1st axis<br>100 kHz<br>2nd axis<br>100 kHz<br>3rd axis<br>100 kHz Servo amp,<br>Stepping motor driver<br>**----- End of picture text -----**<br>
## **Data management**
A special adapter, the FX3U-CF-ADP, for the FX3U and FX3UC enables data to be automatically written to a CF card at specified intervals or under certain conditions. The data is saved in universal CSV format with user-defined file names and automatic timestamps to enhance efficiency.
## **Inverter control**
Integrated FREQROL protocol FX3 series PLCs contain the RS485 communication protocol and special instructions that allow control of all Mitsubishi Electric FREQROL inverters. For all other models, analog inverter control can be used.
## **Serial communication**
From PCs, printers, barcode readers, modems and other PLCs, serial communication increases the flexibility of the FX series system to allow reliable data exchange over a variety of connections.
## **Visualization**
HMI options for the FX series range from simple text-based display units to advanced graphical touch-screen displays (GOT – Graphic Operation Terminals).
**==> picture [296 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
Differential line driver outputs 200 kHz<br>2 axes<br>200 kHz<br>200 kHz<br>Servo amp,<br>Stepping motor driver<br>| sx<br>2 axes<br>200 kHz<br>200 kHz<br>Servo amp,<br>Stepping motor driver<br>of s<<br>Upgraded built-in positioning instructions for easier use<br>* When using high-speed output special adapters, the same numbered I/O terminals on the PLC main unit may not be<br>used.<br>**----- End of picture text -----**<br>
25
Base units FX5U series
~~**2**~~
## **MELSEC iQ-F**
## **The MELSEC FX5U series**
**==> picture [502 x 293] intentionally omitted <==**
**----- Start of picture text -----**<br>
RAM/EEPROM memory for up to<br>64,000 PLC program steps gives<br>Two analog input channels and you plenty of reserve, even for big,<br>one analog output channel. complex applications.<br>With parameter setup, no<br> programming is required.<br>The base units can be expanded to provide<br>configurations with up to 512 inputs<br>and outputs in total. This includes up to<br>256 local inputs and outputs and up to<br>Add-in function boards can be installed in the 384 remote I/O.<br>PLC to provide a second RS485/RS422/RS232/<br>USB communications interface for program- Ws<br>ming or network configurations.<br>Up to eight high-speed inputs for<br>An integrated RUN/<br>STOP switch is available. positioning operations.<br>Connection possibility<br>for ADP modules<br>oe es e Integrated real-time clock with<br>year, month, day and time<br>Integrated SD card<br>slot for datalogging<br>Built-in RS485 port for<br>serial communication Four integrated pulse outputs for<br>frequencies up to 200 kpps. Positioning<br>(with MODBUS® function) Built-in Ethernet port for operations including interrupt, variable<br>up to 8 connections on the speed, and simple interpolation can<br>network easily be set up in tables and executed.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [498 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protective cover<br>See<br>), SSS<br>Analog inputs/outputs<br>Terminals for digital inputs<br>SD memory card slot<br>i Expansion board connector<br>Extension connector<br>SD memory card disable switch<br>RUN/STOP/RESET switch i was \ — LED display<br>Cover of the adapter board terminal I fSoej me B 73, ie} —— Battery connector<br>RS485 terminal resistor yf} |? cece Peta SEEREEET Cover for expansion bus<br>selector switch : . “.<br>RS485 port 1 Terminals for digital outputs<br>Ethernet port<br>-ii ee Protective cover<br>Cover v<br>N ————<br>Cover of expansion slot and<br>optional battery<br>**----- End of picture text -----**<br>
26
Base units FX5U series
~~**2**~~
## ~~**Base units**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** ¨ **FX5UC**
## **Base units FX5U**
The FX5U series CPU modules feature outstanding performance and superior drive control.
- z High-speed system bus
- z Built-in Ethernet port
- z Built-in analog inputs/outputs
- z Built-in positioning (200 kpps, 4-axis)
z Advanced security functions
- z Battery-less and maintenance free
- z Connection of FX5 and FX3 expansion modules possible
- z Connection of connector type FX5 I/O modules possible
- z Built-in RS485 port (with Modbus® function)
- z Built-in SD card slot
## **Base units with 32–80 I/Os**
|Integrated inputs/outputs|32<br>32<br>32<br>32|
|---|---|
|Power supply|24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC|
|Integrated inputs|16<br>16<br>16<br>16|
|Integrated outputs|16<br>16<br>16<br>16|
|Output type<br>Relay<br>Transistor(source type)<br>Relay<br>Transistor(source type)<br>Power consumption<br>W 30<br>30<br>30<br>30||
|Weight|kg 0.7<br>0.7<br>0.7<br>0.7|
|Dimensions (WxHxD)<br>mm 150x90x83<br>150x90x83<br>150x90x83<br>150x90x83<br>**Order information**<br>Art. no. 297436<br>297438<br>280489<br>280491||
|Integrated inputs/outputs|64<br>64<br>64<br>64|
|---|---|
|Power supply|24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC|
|Integrated inputs|32<br>32<br>32<br>32|
|Integrated outputs|32<br>32<br>32<br>32|
|Output type<br>Relay<br>Transistor(source type)<br>Relay<br>Transistor(source type)<br>Power consumption<br>W 40<br>40<br>40<br>40||
|Weight|kg 1.0<br>1.0<br>1.0<br>1.0|
|Dimensions (WxHxD)<br>mm 220x90x83<br>220x90x83<br>220x90x83<br>220x90x83<br>**Order information**<br>Art. no. 301923<br>301945<br>280492<br>280494||
|Integrated inputs/outputs|80<br>80<br>80<br>80|
|---|---|
|Power supply|24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC|
|Integrated inputs|40<br>40<br>40<br>40|
|Integrated outputs|40<br>40<br>40<br>40|
|Output type<br>Relay<br>Transistor(source type)<br>Relay<br>Transistor(source type)<br>Power consumption<br>W 45<br>45<br>45<br>45||
|Weight|kg 1.2<br>1.2<br>1.2<br>1.2|
|Dimensions (WxHxD)<br>mm 285x90x83<br>285x90x83<br>285x90x83<br>285x90x83<br>**Order information**<br>Art. no. 301946<br>301948<br>280495<br>280497||
* Sink type transistor output units on request.
27
Base units FX5U series
~~**2**~~
## ~~�~~ ~~**[Specifications ]**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** ¨ **FX5UC**
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature -20–+55 °C (storage temperature: -25–+75 °C)<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC61131-2: 147 m/s [2] (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC61131-2: 9.8 m/s [2] (resistance to vibrations from 5–150 Hz for 80 minutes along all 3 axes); 4.9 m/s [2] for DIN rail mounting<br>Insulation resistance 10 MΩ, 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>Fuse rating AC powered types: FX5U-32Mm: 3.15 A; FX5U-64Mm and FX5U-80Mm: 5 A, DC powered types: 3.15 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [512 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply DC powered modules AC powered modules<br>specifications (FX5U- m M m /DS/DSS) (FX5U- m MR/ES)<br>100–240 V AC (+10 %/-15 %),<br>Power supply 24 V DC (+20 %/-15%) 50/60 Hz<br>Inrush current at ON 50 A/<0.5 ms (at 24 V DC) FX5U-32M: 25 A/<5 ms (at 100 V AC); 50 A/<5 ms (at 200 V AC);FX5U-64M, FX5U-80M: 30 A/<5 ms (at 100 V AC); 60 A/<5 ms (at 200 V AC)<br>Allowable momentary power failure time 5 ms 10 ms<br>FX5U-32Mm/E: 480 mA<br>Service power supply (24 V DC) — FX5U-64Mm/E: 740 mA<br>FX5U-80Mm/E: 770 mA<br>**----- End of picture text -----**<br>
## **Programming specifications**
**==> picture [512 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX5U<br>Program data<br>I/O points (addresses) Max. total 512 (with remote I/O)<br>Program memory 64,000 steps RAM (internal)<br>Instruction processing time 34 ns/basic instruction<br>Programming language Ladder diagram (LD), structured text (ST), function block diagram/ladder diagram (FBD/LD)<br>Program execution Cyclical execution, refresh mode processing<br>**----- End of picture text -----**<br>
28
Base units FX5UC series
~~**2**~~
## **The MELSEC FX5UC series**
**==> picture [467 x 313] intentionally omitted <==**
**----- Start of picture text -----**<br>
RAM/EEPROM memory for up to<br>64,000 PLC program steps gives<br>you plenty of reserve, even for big,<br>complex applications.<br>Built-in Ethernet port for up to<br>8 connections on the network<br>Ss).<br>\. Se<br>y=<br>The base units can be expanded to provide<br>An integrated RUN/STOP configurations with up to 512 inputs<br>switch is available. and outputs in total. This includes up to<br>256 local inputs and outputs and up to<br>384 remote I/O.<br>Up to eight high-speed inputs for<br> positioning operations.<br>tty [OX weIRS<br>Connection possibility<br>for ADP modules El) |S Integrated real-time clock with year, month, day and time<br>. NU one<br>Built-in RS485 port for<br>serial communication Four integrated pulse outputs for frequen-<br>(with Modbus® function) cies up to 200 kpps. Positioning operations<br>including interrupt, variable speed, and<br>simple interpolation can easily be set up in<br>tables and executed.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [460 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cov er for expansion bus<br>RUN/STOP/RESET switch<br>LED display<br>mortis e ) | ss]<br>SD memory card slot<br>SD memory card LEDs for indicating input/<br>disable switch output status<br>Connector for digital inputs<br>Ethernet port<br>Cover of the adapter<br>board terminal<br>ee Connector for digital outputs<br>\ l on ST foise<br>RS485 port N N a L o ISS Selector switch for input/<br>output status display<br>Nee 98) |S<br>At the bottom side: NN ss<br>P Battery compartment<br>P Power supply terminals<br>P RS485 terminal resistor<br>selector switch<br>**----- End of picture text -----**<br>
29
Base units FX5UC series
~~**2**~~
## ~~**Base units**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** þ **FX5UC**
## **FX5UC-Grundgeräte**
The FX5UC series CPU modules feature outstanding performance and superior drive control.
- z High-speed system bus
- z Built-in Ethernet port
- z Battery-less and maintenance free
- z Connection of FX5 and FX3 expansion modules possible
- z Connection of connector type FX5 I/O modules possible
- z Built-in positioning (200 kpps, 4-axis)
- z Built-in RS485 port (with Modbus® function)
- z Built-in SD card slot
- z Advanced security functions
## **Base units with 32–96 I/Os**
|**Specifications**<br>**FX5UC-32MT/DSS**<br>**FX5UC-64MT/DSS**<br>**FX5UC-96MT/DSS**<br>~~ee~~|**Specifications**<br>**FX5UC-32MT/DSS**<br>**FX5UC-64MT/DSS**<br>**FX5UC-96MT/DSS**<br>~~ee~~|
|---|---|
|Integrated inputs/outputs|32<br>64<br>96|
|Power supply|24 V DC<br>24 V DC<br>24 V DC|
|Integrated inputs|16<br>32<br>48|
|Integrated outputs|16<br>32<br>48|
|Output type|Transistor(source type)<br>Transistor(source type)<br>Transistor(source type)|
|||
|Power consumption|5 W<br>8 W<br>11 W|
|Weight<br>kg|0.2<br>0.3<br>0.35|
|Dimensions (WxHxD)<br>mm|42.1x90x89.1<br>62.2x90x89.1<br>82.3x90x89.1|
|||
|**Order information**<br>Art. no. 283530|Art. no. 283530<br>294579<br>294581|
* Sink type transistor output units on request.
30
Base units FX5UC series
~~**2**~~
## ~~�~~ ~~**[Specifications ]**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** þ **FX5UC**
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature -20–+55 °C (storage temperature: -25–+75 °C)<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage 500 V AC, 1 min.<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC61131-2: 147 m/s [2] (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC61131-2: 4.9 m/s [2] (resistance to vibrations from 8.4–150 Hz for 80 minutes along all 3 axes); 4.9 m/s [2] for DIN rail mounting<br>Insulation resistance ≥10 MΩ, 500 V DC<br>Grounding Class D: Grounding resistance 100 Ω or less<br>Fuse rating 3.15 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [512 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply specifications DC powered base units<br>Power supply 24 V DC (+20 %/-15 %)<br>Inrush current at ON FX5UC-32MT/m: 35 A/<0.5 ms (at 24 V DC)<br>FX5UC-64MT/m, FX5UC-96MT/m: 40 A/<0.5 ms (at 24 V DC)<br>Allowable momentary power failure time 5 ms<br>Service power supply (24 V DC) —<br>**----- End of picture text -----**<br>
## **Programming specifications**
**==> picture [512 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX5UC<br>Program data<br>I/O points (addresses) Max. total 512 (with remote I/O)<br>Program memory 64,000 steps RAM (internal)<br>Instruction processing time 34 ns/basic instruction<br>Programming language Ladder diagram (LD), structured text (ST), function block diagram/ladder diagram (FBD/LD)<br>Program execution Cyclical execution, refresh mode processing<br>**----- End of picture text -----**<br>
31
Base units FX3S series
~~**2**~~
## **MELSEC-F**
## **The MELSEC FX3S series**
**==> picture [503 x 293] intentionally omitted <==**
**----- Start of picture text -----**<br>
The internal service power supply unit<br>for 24 V DC has a capacity of 400 mA.<br>Two integrated analog inputs<br>High-speed inputs for fast counting (FX3S-30MT/ESS-2AD and<br>tasks with counting frequencies of up FX3S-30MR/ES-2AD) only)<br>to 60 kHz and interrupt processing<br>capabilities<br>Integrated real-time clock with<br>year, month, day and time<br>0I —$—S|<br>Flexible installation with the All units feature two analog<br> integrated DIN rail adapter and potentiometers for setpoint<br>screw fastening holes for mount- value entry and an integrated<br>ing on flat surfaces RUN/STOP switch.<br>Your PLC programs are stored in a mainte-<br>| MITSUBISH| fa<br>Lt eal ll nance-free EEPROM user memory with a<br>capacity of 4,000 program steps, so there<br>Integration of interface, extension,<br>and functions adapters for direct ay | on is no need for a backup battery to protect<br>against power failures.<br>installation in the base unit<br>\ MELSEE FXas<br>| 3 i<br>Integrated serial RS422 interface<br>for direct communication with<br>qo. computers<br>Password access protection<br>facility for effective protection<br>of your intellectual property.. Square pulse output (this applies only to transistor units.)<br>Two integrated high speed pulse outputs for frequencies<br>up to 100 kHz for outputting pulse signals and controlling<br>stepping motors<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [472 x 278] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protective cover<br>4 GO000ar Terminal cover<br>\ eS Terminals for digital inputs<br>Connection of the power supply<br>2 analog potentiometers<br>Slot for extension adapter ty RUN/STOP switch<br>Input operating status indicationor memory cassette = Imes er<br>LEDs for indicating the operating status USB interface<br>RS422 interface<br>\ | FXas-14MRIES l _a<br>Output operating status indication<br>Cover for interface, potentiometer and<br>RUN/STOP switch<br>Terminals for digital outputs<br>peR EE MITSUBISHI My Cover for extension slot<br>| _ MELSEC FX3s | |<br>(00000|} Terminal cover<br>Protective cover<br>**----- End of picture text -----**<br>
32
Base units FX3S series
~~**2**~~
## ~~**Base units**~~
## þ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units FX3S**
The FX3S series base units are available with
10 to 30 input/output points.
It is possible to choose between relay and transistor output type.
- z Integrated power supply (AC or DC powered)
- z Maintenance-free EEPROM memory
- z Ample memory capacity (4000 steps) and device ranges
- z High-speed operations
- z Incorporated positioning control
- z Integrated real-time clock
- z FX3S-30MT/ESS-2AD and FX3S-30MR/ES-2AD with two integrated analog inputs (0–10 V DC)
- z System upgrades by exchangeable interface and I/O adapter boards for direct fitting into the base unit
- z LEDs for indicating the input and output status
- z Standard programming unit interface
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3)-compatible programming software, HMIs and hand-held programming units
## **Base units with 10–14 I/Os**
|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-10**<br>**MR/ES**<br>**FX3S-10**<br>**MR/DS**<br>**FX3S-10**<br>**MT/ESS**<br>**FX3S-10**<br>**MT/DSS**<br>**FX3S-14**<br>**MR/ES**<br>**FX3S-14**<br>**MR/DS**<br>**FX3S-14**<br>**MT/ESS**<br>**FX3S-14**<br>**MT/DSS**<br>ee|
|---|---|---|---|---|---|---|---|
|Integrated inputs/outputs<br>10|10|10|10|14|14|14|14|
|Power supply<br>100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|24 V DC|
|Integrated inputs<br>6|6|6|6|8|8|8|8|
|Integrated outputs<br>4|4|4|4|6|6|6|6|
|Output type<br>Relay|Relay|Transistor<br>(source)*|Transistor<br>(source)*|Relay|Relay|Transistor<br>(source)*|Transistor<br>(source)*|
|||||||||
|Power consumption<br>W 19|6|19|6|19|6,5|19|6,5|
|Weight<br>kg 0.30|0.30|0.30|0.30|0.30|0.30|0.30|0.30|
|Dimensions (WxHxD)<br>mm 60x90x75|60x90x49|60x90x75|60x90x49|60x90x75|60x90x49|60x90x75|60x90x49|
|||||||||
|**Order information**<br>Art. no. 267110|271687|267112|271695|267113|271688|267125|271696|
**Base units with 20–30 I/Os**
|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|**Specifications**<br>**FX3S-20**<br>**MR/ES**<br>**FX3S-20**<br>**MR/DS**<br>**FX3S-20**<br>**MT/ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR/ES**<br>**FX3S-30**<br>**MR/DS**<br>**FX3S-30**<br>**MR/ES-2AD**<br>**FX3S-30**<br>**MT/ESS**<br>**FX3S-30**<br>**MT/ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>ee|
|---|---|---|---|---|---|---|---|---|---|---|
|Integrated inputs/outputs|20|20|20|20|30|30|30|30|30|30|
|Power supply|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|100–240 V AC|100–240 V AC|24 V DC|
|Integrated inputs|12|12|12|12|16|16|16|16|16|16|
|Integrated outputs|8|8|8|8|14|14|14|14|14|14|
|Output type|Relay|Relay|Transistor<br>(source)*|Transistor<br>(source)*|Relay|Relais|Relais|Transistor<br>(source)*|Transistor<br>(source)*|Transistor<br>(source)*|
||||||||||||
|Power consumption|W 20|7|20|7|21|8,5|21|21|21|8,5|
|Weight|kg 0.40|0.40|0.40|0.40|0.45|0.45|0.45|0.45|0.45|0.45|
|Dimensions (WxHxD)|mm 75x90x75|75x90x49|75x90x75|75x90x49|100x90x75|100x90x49|100x90x75|100x90x75|100x90x75|100x90x49|
||||||||||||
|**Order information**<br>Art. no. 267126||271689|267128|271697|267129|271690|271654|267131|271686|271698|
* Sink type transistor output units on request.
33
Base units FX3S series
~~**2**~~
## ~~�~~ ~~**[Specifications ]**~~
þ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Noise durability 1,000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage 1,500 V AC, 1 min<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (147 m/s2) (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (Resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 5 MΩ at 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>Fuse rating 250 V 1.0 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply specifications AC powered modules (FX-3S- m M m /E m )<br>Power supply 100–240 V AC (+10 %/-15 %), 50/60 Hz<br>Inrush current at ON 30 A/<5 ms (at 100 V AC);<br>50 A/<5 ms (at 200 V AC)<br>Allowable momentary power 10 ms<br>failure time<br>Primary power supply —<br>External power supply 400 mA<br>(24 V DC)<br>**----- End of picture text -----**<br>
**==> picture [250 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output specifications Relay module Transistor module<br>Switching voltage (max.) V <240 V AC, <30 V DC 5–30 V DC<br>Max. output - per output A 2 0.5<br>current - per group [b] A 8 0.8<br>Max. switching - inductive load 80 VA 12 W<br>current<br>Response time ms 10 <0.2 (<5 µs for Y0,Y1)<br>3,000,000 at 20 VA; 1,000,000 at 35 VA;<br>Life of contacts (switching times) [a]<br>200,000 at 80 VA<br>**----- End of picture text -----**<br>
- 1 Not guaranteed by Mitsubishi Electric
- 2 The limitation applies only per reference terminal for each group with 4 outputs. Please observe the terminal assignments for the group identification
## **Programming specifications**
**==> picture [251 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3S<br>Program data<br>I/O points (addresses) Max. 16 inputs, max 14 outputs (not expandable)<br>4000 steps EEPROM (internal),<br>Program memory exchangeable EEPROM memory cassette<br>Cycle period 0.21 µs /logical instruction<br>Number of instructions 27 sequence instructions, 2 step ladder instructions, 116 applied<br>instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refresh mode processing<br>Program protection Via password<br>**----- End of picture text -----**<br>
**==> picture [250 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3S<br>Operands<br>Internal relays 1,536<br>Special relays 512<br>Step ladder 256<br>Timer 138<br>Ext. preset value via potentiometer 2<br>Counter 67<br>6 single phase inputs (max. 60 kHz),<br>High-speed counter 3 double phase inputs (max. 30 kHz)<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 3,000<br>File register 2,000<br>Index register 16<br>Special register 512 (D8000–D8511)<br>Pointer 2,048<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: K: 2147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
34
Base units FX3G series
~~**2**~~
## **The MELSEC FX3G series**
Integrated high-speed counter inputs for processing fast input signals. For example, you can configure two 60 kHz counters and four 10 kHz counters. Interrupt processing is also handled via the inputs.
Add-in function boards can be installed in the PLC to provide a second RS485/RS422/ RS232 communications interface for programming or network configurations. Analog function boards for input and output and a function board with 8 analog potentiometers are also available as add-in.
RAM/EEPROM memory for up to 32,000 PLC program steps gives you plenty of reserve, even for big, complex applications.
The base units can be expanded to provide configurations with up to 256 inputs and outputs with modular and compact extension unit **s** (128 directly and 256 in common by using remote I/Os via a network).
**==> picture [69 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated real-time<br>clock with year, month,<br>day and time<br>**----- End of picture text -----**<br>
An integrated RUN/STOP switch is available.
Connection possibility for special function adapter modules
Two integrated serial interfaces for direct communication with computers.
Two integrated pulse outputs for frequencies from 2 to 100,000 Hz for controlling stepping motors and outputting pulse-width modulated signals.
## **Description of the unit components**
**==> picture [102 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
Memory cassette, display module,<br>and expansion board connector<br>2 analog potentiometers<br>RUN/STOP switch<br>Option battery holder<br>Programming port: RS422<br>Programming port: USB<br>**----- End of picture text -----**<br>
**==> picture [93 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal cover<br>Terminal protector<br>Input terminals<br>Input indicator LEDs<br>Operation status indicator LEDs<br>Expansion bus connector cover<br>Output indicator LEDs<br>Output terminals<br>Terminal protector<br>**----- End of picture text -----**<br>
**==> picture [44 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal cover<br>**----- End of picture text -----**<br>
**==> picture [108 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
Flip cover for programming port,<br>potentiometer and Run/Stop switch<br>Cover for the left extension slot<br>**----- End of picture text -----**<br>
Cover of the right extension slot and the optional battery
35
Base units FX3G series
~~**2** a~~
## ~~**Base units**~~
## ¨ **FX3S** þ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units FX3G**
The FX3G series base units are available with 14 to 60 input/output points.
It is possible to choose between relay and transistor output types.
- z Integrated USB interface for communication between PLCs and PC
- z Integrated serial interface for communication between PCs and HMI
- z LEDs for indicating the input and output status
- z Detachable terminal blocks for all units
z Slot for memory cassettes
- z Integrated real-time clock
- z Integrated positioning control
- z Exchangeable interface and extension adapters for direct mounting into a base unit
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
## **Base units with 14–24 I/Os**
|Integrated inputs/outputs|14<br>14<br>14<br>14<br>24<br>24<br>24<br>24|
|---|---|
|Power supply|100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC|
|Integrated inputs|8<br>8<br>8<br>8<br>14<br>14<br>14<br>14|
|Integrated outputs|6<br>6<br>6<br>6<br>10<br>10<br>10<br>10|
|Output type<br>Power consumption|Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>W 31<br>31<br>19<br>19<br>32<br>32<br>21<br>21|
|Weight|kg 0.50<br>0.50<br>0.50<br>0.50<br>0.55<br>0.55<br>0.55<br>0.55|
|Dimensions (WxHxD)|mm 90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86|
## **Base units with 40–60 I/Os**
|Integrated inputs/outputs|40<br>40<br>40<br>40<br>60<br>60<br>60<br>60|
|---|---|
|Power supply|100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC|
|Integrated inputs|24<br>24<br>24<br>24<br>36<br>36<br>36<br>36|
|Integrated outputs|16<br>16<br>16<br>16<br>24<br>24<br>24<br>24|
|Output type<br>Power consumption|Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>W 37<br>37<br>25<br>25<br>40<br>40<br>29<br>29|
|Weight|kg 0.70<br>0.70<br>0.70<br>0.70<br>0.85<br>0.85<br>0.85<br>0.85|
|Dimensions (WxHxD)|mm 130x90x86<br>130x90x86<br>130x90x86<br>130x90x86<br>175x90x86<br>175x90x86<br>175x90x86<br>175x90x86|
* Sink type transistor output units on request.
36
Base units FX3GE series
~~**2**~~
## **The MELSEC FX3GE series**
Integrated high-speed counter inputs for processing fast input signals. For example, you can configure two 60 kHz counters and four 10 kHz counters. Interrupt processing is also handled via the inputs.
RAM/EEPROM memory for up to 32,000 PLC program steps gives you plenty of reserve, even for big, complex applications.
Add-in function boards can be installed in the PLC to provide a second RS485/RS422/ RS232 communications interface for programming or network configurations. Analog function boards for input and output and a function board with 8 analog potentiometers are also available as add-in.
The base units can be expanded to provide configurations with up to 256 inputs and outputs with modular and compact extension units (128 directly and 256 in common by using remote I/Os via a network).
Integrated real-time clock with year, month, day and time
Connection possibility for special function adapter modules
An integrated RUN/STOP switch is available. Two integrated serial interfaces for direct communication with computers.
Two integrated pulse outputs for frequencies from 2 to 100,000 Hz for controlling stepping motors and outputting pulse-width modulated signals.
## **Description of the unit components**
**==> picture [473 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
_—_ Terminal cover<br>Memory cassette, display module,<br>and extension board connector<br>i)<br>1 Terminal protector<br>Terminals for digital inputs<br>Terminals for analog inputs<br>LEDs for input status<br>2 analog potentiometers<br>RUN/STOP switch<br>Battery bracket<br>Connection for adapter modules<br>Operation status indicator LEDs<br>RS-422 interface —l.; 8 o f O : rr<br>i a ) © =e<br>USB interface a P07) |. ) Cover for the extension slot<br>RJ45 socket (10BASE-T/100BASE-TX) LEDs for output status<br>Ne S e Terminals for digital outputs<br>Terminals for analog output<br>Terminal protector<br>—— Terminal cover<br>LOT<br>INPUTANALOG V1+ I1+ V2+ I2+ VI-<br>100M<br>SD/RD<br>ERR<br>OPEN<br>10BASE-T/100BASE-TX<br>V+ I+ VI-<br>OUTPUTANALOG<br>**----- End of picture text -----**<br>
Cover for interface, potentiometer and RUN/STOP switch
**==> picture [95 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cover for the extension slot and<br>the optional battery<br>**----- End of picture text -----**<br>
37
Base units FX3GE series
~~**2**~~
## ~~|~~ ~~**Base units**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** þ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units FX3GE**
**==> picture [195 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>a ).<br>| oft<br>**----- End of picture text -----**<br>
The FX3GE series base units are available with 24 or 40 input/output points.
All base units are equipped with relay outputs.
- z Integrated analog input (2 ch)
- z Integrated analog output (1 ch)
- z Integrated Ethernet interface
- z Integrated USB interface for communication between PLC and PC
- z Integrated serial interface for communication between PLC and HMI
- z LEDs for indicating the input and output status
- z Connection of inputs and outputs via terminals
- z Slot for memory cassettes
- z Integrated positioning control
- z Expandable with special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
## **Base units with 24 I/Os**
|**Specifications**|**FX3GE-24**<br>**MR/ES**|**FX3GE-24**<br>**MT/ESS**|**FX3GE-24**<br>**MR/DS**<br>**FX3GE-24**<br>**MT/DSS**|
|---|---|---|---|
|Integrated inputs/outputs|24|24|24<br>24|
|Power supply|100–240 V AC|100–240 V AC|24 V DC<br>24 V DC|
|Integrated inputs|14|14|14<br>14|
|Integrated outputs|10|10|10<br>10|
|Output type|Relay|Transistor<br>(source)*|Relay<br>Transistor<br>(source)*|
|||||
|Power consumption<br>W|32|32|21<br>21|
|Weight<br>kg|0.6|0.55|0.55<br>0.55|
|Dimensions (WxHxD)<br>mm|130x90x86|90x90x86|90x90x86<br>90x90x86|
|||||
|**Order information**<br>Art. no. 264869|Art. no. 264869|269884|269917<br>269919|
## **Base units with 40 I/Os**
|**Specifications**|**FX3GE-40**<br>**MR/ES**<br>**FX3GE-40**<br>**MT/ESS**<br>**FX3GE-40**<br>**MR/DS**|**FX3GE-40**<br>**MT/DSS**|
|---|---|---|
||||
|Integrated inputs/outputs|40<br>40<br>40|40|
|Power supply|100–240 V AC<br>100–240 V AC<br>24 V DC|24 V DC|
|Integrated inputs|24<br>24<br>24|24|
|Integrated outputs|16<br>16<br>16|16|
|Output type|Relay<br>Transistor<br>(source)*<br>Relay|Transistor<br>(source)*|
||||
|Power consumption<br>W|37<br>37<br>25|25|
|Weight<br>kg|0.8<br>0.70<br>0.70|0.70|
|Dimensions (WxHxD)<br>mm|175x90x86<br>130x90x86<br>130x90x86|130x90x86|
||||
|**Order information**<br>Art. no. 264870|Art. no. 264870<br>269916<br>269920|269922|
* Sink type transistor output units on request.
38
Base units FX3GC series
~~**2**~~
## **The MELSEC FX3GC series**
**==> picture [481 x 297] intentionally omitted <==**
**----- Start of picture text -----**<br>
RAM/EEPROM memory for up to<br>32,000 PLC program steps gives<br>Integrated high-speed counter inputs you plenty of reserve, even for big,<br>for processing fast input signals. For complex applications.<br>example, you can configure two 60 kHz<br>counters and four 10 kHz counters.<br>Interrupt processing is also handled<br>via the inputs. The base units can be expanded<br>to provide configurations with up<br>= to 256 inputs and outputs with<br>0 SSE modular and compact extension units<br>(128 directly and 256 in common by<br>Wee<br>using remote I/Os via a network).<br>An integrated RUN/STOP<br>switch is available.<br>Integrated real-time<br>clock with year, month,<br>day and time<br>ul| RSSNohOSSAe a<br>Two integrated serial interfaces for<br>direct communication with computers.<br>WE<br>|) 2S<br>Two integrated pulse outputs for<br> frequencies from 2 to 100,000 Hz for con-<br>Connection possibility for special<br>trolling stepping motors and outputting<br>function adapter modules<br>pulse-width modulated signals.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [483 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operation status indicator LEDs<br>N<br>Protective cover for the<br>)_ . ———_ sus! a I extension bus<br>USB interface for peripheral devices<br>ESEPee OMT -oc- Sa RUN/STOP switch<br>Input indicator LEDs Ay oi XJ<br>RS422 interface for<br>peripheral devices<br>Cover for adapter<br>module connection<br>Output indicator LEDs<br>Ne<br>Adapter module connection rs | es TT T Who NG<br>Connector for digital outputs<br>Connector for digital inputs<br>i \ iJ E<br>iit<br>Battery connector<br>ij<br>Back-up battery<br>i)<br>|<br>Battery cover<br>**----- End of picture text -----**<br>
39
Base units FX3GC series
~~**2**~~
## ~~**Base units**~~
## ¨ **FX3S** ¨ **FX3G** þ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units FX3GC**
The base units FX3GC-32 MT/m are available with 32 input/output points.
The base units are equipped with transistor outputs.
- z Integrated USB interface for communication between PLC and PC
- z Integrated serial interface for communication between PLC and HMI
- z Integrated positioning control
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
- z LEDs for indicating the input and output status
- z Connection of inputs and outputs via connectors.
## **Base units with 32 I/Os**
|**Specifications**<br>**FX3GC-32 MT/D**<br>**FX3GC-32 MT/DSS**<br>~~ee~~|**Specifications**<br>**FX3GC-32 MT/D**<br>**FX3GC-32 MT/DSS**<br>~~ee~~|
|---|---|
|Integrated inputs/outputs|32<br>32|
|Power supply|24 V DC<br>24 V DC|
|Integrated inputs|16<br>16|
|Integrated outputs|16<br>16|
|Output type|Transistor (sink)<br>Transistor (source)|
|||
|Power consumption|W 8<br>8|
|Weight|kg 0.2<br>0.2|
|Dimensions (WxHxD)|mm 34x90x87<br>34x90x87|
|||
|**Order information**<br>Art. no. 251545<br>251546||
40
Base units FX3G/FX3GC/FX3GE series
~~**2**~~
## ~~�~~ ~~**[Specifications ]**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Environmental specifications**
**==> picture [512 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications FX3G FX3GE FX3GC<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage 1500 V AC, 1 min 500 V AC, 1 min<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (147 m/s2) (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 5 MΩ, 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>Fuse rating For FX3G-40MFor FX3G-14Mmm and FX3G-60M and FX3G-24Mmm: 250 V 3.15 A: 250 V 1 A; FX3GE-24MFX3GE-40Mmm: 250 V 1 A; : 250 V 3.15 A 125 V 3.15 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply specifications FX3G FX3GE FX3GC<br>AC 100–240 V (+10 % /-15 %), 50/60 Hz —<br>Power supply<br>DC 24 V DC (+20 %/-15 %)<br>AC [30 A/<5 ms (at 100 V AC); ] —<br>50 A/<5 ms (at 200 V AC)<br>Inrush current at ON<br>30 A/<0.5 ms<br>DC 30 A/<1 ms (at 24 V DC) (at 24 V DC)<br>Allowable momentary power 10 ms 10 ms 5 ms<br>failure time<br>External power supply 400 mA 400 mA —<br>(24 V DC)<br>**----- End of picture text -----**<br>
**==> picture [250 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Relay modules Transistor modules Transistor modules<br>Output specifications FX3G/FX3GE FX3G/FX3GE FX3GC<br>Switching voltage (max.) V <240 V AC, <30 V DC 5–30 V DC 5–30 V DC<br>Max. output - per output A 2 0.5 Y000, Y001: 0.3Y002–Y017: 0.1<br>current<br>- per group A 8 [b] 0.8 [b] 0.8<br>Max.<br>switching - inductive load W 80 VA 12 W Y000, Y001: 7.2Y002–Y017: 2.4<br>current<br><0.2 <0.2<br>Response time ms 10 (<5 µs for Y0, Y1) [1] (<5 µs for Y0, Y1)<br>**----- End of picture text -----**<br>
- 1 The 40 and 60 I/O points main units supports 5 μs for Y2.
- 2 This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and 2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
## **Programming specifications**
**==> picture [251 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3G FX3GE FX3GC<br>Program data<br>I/O points (addresses) 256 total (combined local and CC-Link remote I/O)<br>Address range Max. 128 direct addressing and max. 128 remote I/O<br>Program memory 32,000 steps EEPROM (internal), exchangeable EEPROM memory cassette<br>Cycle period 0.21 μs or 0.42 μs/contact instruction<br>29 sequence instructions,<br>Number of instructions 29 sequence instructions, 2 step ladder 2 step ladder instructions,<br> instructions, 123 applied instructions 122 applied instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refreshmode processing<br>Program protection Via password<br>**----- End of picture text -----**<br>
**==> picture [250 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3G FX3GE FX3GC<br>Operands<br>Internal relays 7,680<br>Special relays 512<br>Step ladder 4,096<br>Timer 320<br>Ext. preset value via 2<br>potentiometer<br>Counter 235<br>6 single phase inputs (max. 60 kHz),<br>High-speed counter 3 double phase inputs (max. 30 kHz)<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 8,000<br>File register 24,000 (R0~R23999) internal/optional memory 24,000 (R0~R23999)<br>Extension file register 24,000 (ER0~ER23999)<br>Index register 16<br>Special register 512 (D8000–D8511)<br>Pointer 2,048<br>Nestings 8<br>Interrupt inputs 6<br>Constants 16 bits: K: -32768–+32767, hex: 0–FFFF<br>32 bits: K: 2147483648–+2147483647, hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
41
Base units FX3U series
~~**2**~~
## **The MELSEC FX3U series**
**==> picture [510 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated high-speed counter inputs for<br>processing fast input signals. For example,<br>you can configure six 100 kHz counters and<br>two 10 kHz counters.<br>RAM/EEPROM memory for up to<br>Interrupt processing is also handled via the<br>64,000 PLC program steps gives<br>inputs.<br>you plenty of reserve, even for big,<br>complex applications.<br>Add-in function boards can be installed in the The base units can be expanded to provide<br>PLC to provide a second RS485/RS422/RS232/ configurations with up to 384 inputs and<br>USB communications interface for program- outputs with compact extension units<br>ming or network configurations. | S ii [ee (total of 384 only by using main unit I/Os,<br>extension unit I/Os and remote I/Os).<br>ii MITSUBISHI ueisec PTETi<br>nl = =<br>Connection possibility for ra Integrated real-time clock with<br>special function adapter modules<br>year, month, day and time<br>An integrated RUN/STOP switch<br>is available.<br>Three integrated pulse outputs for frequen-<br>cies up to 100 kHz with deceleration and<br>acceleration ramps for controlling stepping<br>Integrated serial interface for direct motors and outputting pulse-width modu-<br>communication with computers lated signals.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [502 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
Battery cover<br>Protective cover<br>Terminal block cover<br>aa a<br>Input terminals<br>Battery SSS SSS Input indicator LEDs<br>Operation status indicator LEDs<br>Installation place for FX3U-7DM<br>Extension device connecting<br>js & wom | cays connector cover<br>Expansion board dummy cover Output indicator LEDs<br>RUN/STOP switch<br>| e e<br>Output terminals<br>Periphal device Terminal block cover<br>connecting connector<br>MITSUBISHI WELSEC | I erelelelelelerorororeler=2<br>Top cover with Model name Protective cover<br>(used, if FX3U-7DM<br>is not installed)<br>**----- End of picture text -----**<br>
42
Base units FX3U series
~~**2**~~
## ~~|~~ ~~**Base units**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units FX3U**
The FX3U series base units are available with 16, 32, 48, 64, 80 or 128 input/output points expandable to 384 points.
Models are available for selection with relay or transistor outputs.
- z Integrated serial interface for communication between PCs and HMI
- z Integrated positioning control
- z Exchangeable interface modules for direct mounting into a base unit
- z LEDs for indicating the input and output status
- z Slot for memory cassettes
- z Integrated real-time clock
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
## **Base units with 16 I/Os**
|**Specifications**|**FX3U-16**<br>**MR/DS**<br>**FX3U-16**<br>**MR/ES**<br>**FX3U-16**<br>**MT/DSS**<br>**FX3U-16**<br>**MT/ESS**|
|---|---|
|Integrated inputs/outputs|16<br>16<br>16<br>16|
|Power supply|24 V DC<br>100–240 V AC<br>24 V DC<br>100–240 V AC|
|Integrated inputs|8<br>8<br>8<br>8|
|Integrated outputs|8<br>8<br>8<br>8|
|Output type|Relay<br>Relay<br>Transistor<br>(source)*<br>Transistor<br>(source)*|
|||
|Power consumption|25 W<br>30 VA<br>25 W<br>30 VA|
|Weight<br>kg|0.6<br>0.6<br>0.6<br>0.6|
|Dimensions (WxHxD)<br>mm|130x90x86<br>130x90x86<br>130x90x86<br>130x90x86|
|||
|**Order information**<br>Art. no. 231498|Art. no. 231498<br>231486<br>231503<br>231492|
## **Base units with 32 I/Os**
|**Specifications**|**FX3U-32**<br>**MR/DS**<br>**FX3U-32**<br>**MR/ES**<br>**FX3U-32**<br>**MT/DSS**<br>**FX3U-32**<br>**MT/ESS**|
|---|---|
|Integrated inputs/outputs|32<br>32<br>32<br>32|
|Power supply|24 V DC<br>100–240 V AC<br>24 V DC<br>100–240 V AC|
|Integrated inputs|16<br>16<br>16<br>16|
|Integrated outputs|16<br>16<br>16<br>16|
|Output type|Relay<br>Relay<br>Transistor<br>(source)*<br>Transistor<br>(source)*|
|||
|Power consumption|30 W<br>35 VA<br>30 W<br>35 VA|
|Weight<br>kg|0.65<br>0.65<br>0.65<br>0.65|
|Dimensions (WxHxD)<br>mm|150x90x86<br>150x90x86<br>150x90x86<br>150x90x86|
|||
|**Order information**<br>Art. no. 231499|Art. no. 231499<br>231487<br>231504<br>231493|
Note: Further special versions are available on request * Sink type transistor output units on request.
43
Base units FX3U series
~~**2**~~
## ~~�~~ ~~**[Base units ]**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units with 48 I/Os**
**==> picture [512 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-48 FX3U-48 FX3U-48 FX3U-48<br>Specifications MR/DS MR/ES MT/ESS MT/DSS<br>Integrated inputs/outputs 48 48 48 48<br>Power supply 24 V DC 100–240 V AC 100–240 V AC 24 V DC<br>Integrated inputs 24 24 24 24<br>Integrated outputs 24 24 24 24<br>Transistor Transistor<br>Output type Relay Relay<br>(source)* (source)*<br>Power consumption 35 W 40 VA 40 VA 35 W<br>Weight kg 0.85 0.85 0.85 0.85<br>Dimensions (WxHxD) mm 182x90x86 182x90x86 182x90x86 182x90x86<br>Order information Art. no. 231500 231488 231494 231505<br>**----- End of picture text -----**<br>
## **Base units with 64 I/Os**
**==> picture [512 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-64 FX3U-64 FX3U-64 FX3U-64<br>Specifications MR/DS MR/ES MT/ESS MT/DSS<br>Integrated inputs/outputs 64 64 64 64<br>Power supply 24 V DC 100–240 V AC 100–240 V AC 24 V DC<br>Integrated inputs 32 32 32 32<br>Integrated outputs 32 32 32 32<br>Transistor Transistor<br>Output type Relay Relay<br>(source)* (source)*<br>Power consumption 40 W 45 VA 45 VA 40 W<br>Weight kg 1.0 1.0 1.0 1.0<br>Dimensions (WxHxD) mm 220x90x86 220x90x86 220x90x86 220x90x86<br>Order information Art. no. 231501 231489 231495 231506<br>**----- End of picture text -----**<br>
## **Base units with 80–128 I/Os**
**==> picture [512 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-80 FX3U-80 FX3U-80 FX3U-80 FX3U-128 FX3U-128<br>Specifications MR/DS MR/ES MT/DSS MT/ESS MR/ES MT/ESS<br>Integrated inputs/outputs 80 80 80 80 128 128<br>Power supply 24 V DC 100–240 V AC 24 V DC 100–240 V AC 100–240 V AC 100–240 V AC<br>Integrated inputs 40 40 40 40 64 64<br>Integrated outputs 40 40 40 40 64 64<br>Transistor Transistor Transistor<br>Output type Relay Relay Relay<br>(source)* (source)* (source)*<br>Power consumption 45 W 50 VA 45 W 50 VA 65 VA 65 VA<br>Weight kg 1.2 1.2 1.2 1.2 1.8 1.8<br>Dimensions (WxHxD) mm 285x90x86 285x90x86 285x90x86 285x90x86 350x90x86 350x90x86<br>Order information Art. no. 231502 231490 231507 231496 231491 231497<br>**----- End of picture text -----**<br>
Note: Further special versions are available on request * Sink type transistor output units on request.
44
Base units FX3U series
~~**2**~~
## ~~�~~ ~~**[Specifications ]**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Environmental specifications**
**==> picture [512 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Protection IP10<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 5 MΩ, 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>Fuse rating From FX3U-16Mm to FX3U-32Mm: 3.15 A; from FX3U-48Mm to FX3U-128Mm: 5 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC powered modules AC powered modules<br>Power supply specifications (FX3U- m M m /DS/DSS) (FX3U- m MR/ES)<br>100–240 V AC (+10 %/-15 %),<br>Power supply 24 V DC (+20 %/-30 %) 50/60 Hz<br>Inrush current at ON — 30 A/<5 ms (at 100 V AC);<br>65 A/<5 ms (at 200 V AC)<br>Allowable momentary power 5 ms 10 ms<br>failure time<br>Primary power supply 24 V DC —<br>External power supply (24 V DC) — FX3U-16/32MR/ES: 400 mA/ FX3U-48–128MR/ES: 600 mA<br>**----- End of picture text -----**<br>
**==> picture [250 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output specifications Relay modules Transistor modules<br>Switching voltage (max.) V <240 V AC, <30 V DC 5–30 V DC<br>Max. output - per output A 2 0.5/0.3 [ a]<br>current - per group* A 8 0.8/1.6 [b]<br>Max. switching - inductive load 80 VA 12 W/7.2 W<br>current<br>Response time ms 10 <0.2 (Y0,Y1<30 µs)<br>3,000,000 at 20 VA; 1,000,000 at 35 VA;<br>Life of contacts (switching times) [c] 200,000 at 80 VA<br>**----- End of picture text -----**<br>
a or Y0 and Y1 = 0.3 A; all others 0.5 A b 0.8 for 4 per group and 1.6 for 8 per group
c Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and 2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
## **Programming specifications**
**==> picture [251 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3U<br>Program data<br>I/O points (addresses) Max. total 384 (with remote I/O)<br>Address range Max. 256 direct addressing and max. 256 network I/Os<br>64,000 steps RAM (internal),<br>Program memory exchangeable FLROM for easy program exchange<br>Cycle period 0.065 µs/basic instruction<br>Number of instructions 27 sequence instructions, 2 step ladder instructions,<br>209 applied instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refresh mode processing<br>Program protection Password protection with 3 protection levels*<br>**----- End of picture text -----**<br>
* Protection levels may only be changed with FX-10P/FX-20P/FX-30P.
**==> picture [250 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3U<br>Operands<br>Internal relays 7,680<br>Special relays 512<br>Step ladder 4,096<br>Timer 512<br>Counter 235<br>High-speed counter 16<br>1 phase, 8 points max: 100 kHz/6 points<br>High-speed counter speed 10 kHz/2 points<br>2 phase, 2 points max: 50 kHz/2 points<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 8,000<br>Extension file register 32,768<br>Index register 16<br>Special register 512<br>Pointer 4,096<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: K: 2147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
45
Base units FX3UC series
~~**2** a~~
## **The MELSEC FX3UC series**
**==> picture [445 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated RUN/STOP switch<br>Integrated serial interface<br>for direct communication RAM/EEPROM memory for up to<br>64,000 PLC program steps gives<br>with computers<br>you plenty of reserve, even for big,<br>SN<br>complex applications.<br>} Q<br>Interface adapter connection for The base units can be expanded<br> second communications interface un to provide configurations with<br>RS485/RS422/RS232 up to 384 inputs and outputs<br>with compact extension units<br>(total of 384 only by using main<br>uy S N unit I/Os, extension unit I/Os<br>and remote I/Os).<br>Integrated high-speed counter inputs for processing XN<br>fast input signals. For example, you can configure<br>six 100 kHz counters and two 10 kHz counters. Three integrated pulse outputs for frequencies up to<br>Interrupt processing is also handled via the inputs. 100 kHz with deceleration and acceleration ramps for<br>controlling stepping motors and outputting pulse-<br>width modulated signals.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [494 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
RUN/STOP switch Input indicator LEDs<br>Operation status indicator LEDs<br>Output indicator LEDs<br>Slot for memory cassettes<br>= ="<br>Protective cover for the<br>extension bus<br>Memory cassette<br>(optional)<br>Extension bus (lateral)<br>Connection for<br>programming units<br>Cover for adapter<br>module connection<br>Back-up battery 4 Ay Connector for digital outputs<br>Battery cover<br>Connector for digital inputs<br>**----- End of picture text -----**<br>
46
Base units FX3UC series
~~**2**~~
## ~~**Base units**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Base units FX3UC**
The base units of the FX3UC series are available in versions with 16, 32, 64 or 96 inputs/outputs (expandable to 384 I/Os).
The units are available with transistor outputs only.
- z Integrated serial interface for communication between PCs and HMI
- z Same instruction set as FX3U
- z Integrated positioning control
- z Very compact dimensions
- z LEDs for indicating the input and output status
- z Slot for memory cassette
- z Adapter modules and system cabling sets available for units with ribbon cable connectors
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
## **Base units with 16–96 I/Os**
|**Specifications**|**FX3UC-16**<br>**MT/DSS**<br>**FX3UC-32**<br>**MT/DSS**<br>**FX3UC-64**<br>**MT/DSS**<br>**FX3UC-96**<br>**MT/DSS**|
|---|---|
|Integrated inputs/outputs|16<br>32<br>64<br>96|
|Power supply|24 V DC(+20 %,-15 %)<br>24 V DC(+20 %,-15 %)<br>24 V DC(+20 %,-15 %)<br>24 V DC(+20 %,-15 %)|
|Integrated inputs|8<br>16<br>32<br>48|
|Integrated outputs|8<br>16<br>32<br>48|
|Output type|Transistor (source)*<br>Transistor (source)*<br>Transistor (source)*<br>Transistor (source)*|
|||
|Power consumption<br>W|6<br>8<br>11<br>14|
|Weight<br>kg|0.2<br>0.2<br>0.3<br>0.35|
|Dimensions (WxHxD)<br>mm|34x90x74<br>34x90x74<br>59.7x90x74<br>85.4x90x74|
|||
|**Order information**<br>Art. no. 231508|Art. no. 231508<br>231509<br>231510<br>231511|
* Sink type transistor output units on request.
## **System cabling**
A choice of terminal blocks with screw or spring terminals are available for easy wiring of the FX3UC modules with standard ribbon cable connectors.
For detailed information about the terminal blocks, please refer to chapter accessories.
**==> picture [299 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output terminal block with screw or<br>spring terminals. It can be fitted with<br>relay or transistor outputs.<br>Input terminal block with screw<br>or spring terminals.<br>j (P2at——\<br>ul<br>.0 .1 .2 .3 .4 .5 .6 .7<br>A2- A2- A2- A2- A2- A2- A2- A2-<br>24V 24V 24V 24V 24V 24V 24V 24V<br>.0 .1 24V+.2 .3 -PLC-V8/FLK14/OUT.4Art. 22 95 55 4.5 .6 .7<br>**----- End of picture text -----**<br>
47
Base units FX3UC series
~~**2**~~
## ~~�~~ ~~**[Specifications ]**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Protection IP10<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 500 V DC, 5 MΩ<br>Ground Class D: Grounding resistance 100 Ω or less<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply specifications Alle modules<br>Power supply 24 V DC (+20 %/-30 %)<br>Inrush current at ON —<br>Allowable momentary power 5 ms<br>failure time<br>Primary power supply 24 V DC<br>External power supply (24 V DC) —<br>**----- End of picture text -----**<br>
**==> picture [251 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output specifications Alle modules<br>Switching voltage (max.) V 5–30 V DC<br>Max. output - per output A 0.1/0.3 [a]<br>current - per group* A 0.8/1.6<br>Max. switching - inductive load 2.4 W/7.2 W [b]<br>current<br>Response time ms <0.2 (Y0,Y1<30 µs)<br>3,000,000 at 20 VA; 1,000,000 at 35 VA;<br>Life of contacts (switching times) [ c] 200,000 at 80 VA<br>**----- End of picture text -----**<br>
a or Y0 and Y1 = 0.3 A; all others 0.1 A b 7.2 W for Y0 to Y3, all other outputs 2.4 W
c Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and 2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
## **Programming specifications**
**==> picture [512 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3UC System specifications FX3UC<br>Program data Operands<br>I/O points (addresses) Max. total 384 (with remote I/O) Internal relays 7,680<br>Address range Max. 256 direct addressing and max. 256 network I/Os Special relays 512<br>64,000 steps RAM (internal), exchangeable FLROM for Step ladder 4,096<br>Program memory easy program exchange Timer 512<br>Cycle period 0.065 µs/basic instruction Counter 235<br>Number of instructions 27 sequence instructions, 2 step ladder instructions, High-speed counter 16<br>209 applied instructions<br>1 phase, 8 points max: 100 kHz/6 points<br>Programming language Step ladder, instruction list, SFC High-speed counter speed 10 kHz/2 points<br>Program execution Cyclical execution, refresh mode processing 2 phase, 2 points max: 50 kHz/2 points<br>Program protection Password protection with 3 protection levels* Real-time clock Year, month, day, hour, minute, second, weekday<br>* Protection levels may only be changed with FX-30P. Data register 8,000<br>Extension file register 32,768<br>Index register 16<br>Special register 512<br>Pointer 4,096<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: 2K: 147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
48
I/O extension
~~**3**~~
## ~~**Powered extension units**~~
## ¨ **FX3S** þ **FX3G** ¨ **FX3GC** þ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Extension units FX2N**
The FX2N series extension units are available with 32 or 48 input/output points.
It is possible to choose between relay and transistor output type.
- z LEDs for indicating the input and output status
- z MELSEC FX3G/FX3GE and FX3U series compatible
- z Detachable terminal blocks
- z Integrated service power supply with 250 mA or 460 mA
|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|
|---|---|---|---|---|---|---|
|Integrated inputs/outputs|32<br>32<br>48<br>48<br>48<br>48||||||
|Power supply<br>AC range(+10 %,<br>Frequencyat AC<br>DC range(+20 %,|,-15 %)<br>100–240 V<br>100–240 V<br>—<br>100–240 V<br>—<br>100–240 V||||||
||Hz 50/60<br>50/60<br>—<br>50/60<br>—<br>50/60||||||
||+20 %,-30 %)<br>—<br>—<br>24 V<br>—<br>24 V<br>—||||||
|Max. input apparentpower|35 VA<br>30 W<br>45 VA<br>30 W<br>45 VA||||||
|Inrush current at ON|100 V AC 40 A<5 ms<br>40 A<5 ms<br>—<br>40 A<5 ms<br>40 A<5 ms<br>40 A<5 ms||||||
||200 V AC 60 A<5 ms<br>—<br>—<br>60 A<5 ms<br>60 A<5 ms<br>60 A<5 ms||||||
|Allowable momentary power failure time|ower failure time<br>ms 10<br>10<br>5<br>10<br>5<br>10||||||
|External servicepower supply (24 V DC)|mA 250<br>250<br>—<br>460<br>—<br>460||||||
|Power supplyint. bus(5 V DC)|mA 690<br>690<br>690<br>690<br>690<br>690||||||
|**Inputs**|||||||
|Integrated inputs|16<br>16<br>24<br>24<br>24<br>24||||||
|Min. current for logical 1|mA 3.5<br>3.5<br>3.5<br>3.5<br>3.5<br>3.5||||||
|Max. current for logical 0|mA 1.5<br>1.5<br>1.5<br>1.5<br>1.5<br>1.5||||||
|Response time|For all extension units of the MELSEC FX2N series: 10 ms(at time of shipment)||||||
|**Outputs**|||||||
|Integrated outputs|16<br>16<br>24<br>24<br>24<br>24||||||
|Output type|Relay<br>Transistor<br>(source)<br>Relay<br>Relay<br>Transistor<br>(source)<br>Transistor<br>(source)||||||
|Switchingvoltage(max.)|Generallyfor relayversion: <264 V AC,<30 V DC;for transistor version: 5–30 V DC||||||
|Max. output<br>current<br>-per output<br>-pergroup*|A 2<br>0.5<br>2<br>2<br>0.5<br>0.5||||||
||A 8<br>0.8/1.6b<br>8<br>8<br>0.8/1.6b<br>0.8 /1.6b||||||
|Max. switching<br>ower<br>- inductive load|- inductive load<br>W 80<br>12<br>80<br>80<br>12<br>12||||||
|Response time|ms 10<br><0.2<br>10<br>10<br><0.2<br><0.2||||||
|Life of contacts(switchingtimes)a|For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA;1,000,000 at 35 VA;200,000 at 80 VA(for relayoutput only)||||||
|**Mechanical data**|||||||
|Weight|kg 0.65<br>0.65<br>0.85<br>0.85<br>0.85<br>0.85||||||
|Dimensions (WxHxD)|mm 150x90x87<br>150x90x87<br>182x90x87<br>182x90x87<br>182x90x87<br>182x90x87||||||
1 Not guaranteed by Mitsubishi Electric
2 0.8 for 4 per group and 1.6 for 8 per group
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
49
I/O extension
~~**3**~~
## ~~**Powered extension units**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
## **Powered input/output modules FX5**
The powered input/output modules of the FX5 series are available with AC or DC power supply. They can be used in a system with a FX5U or FX5UC CPU module. Both relay and transistor output types are available.
- z LEDs for indicating the input and output status
- z MELSEC FX5U and FX5UC series compatible
- z Detachable terminal blocks
- z AC powered I/O modules with integrated service power supply with 310 mA
|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|
|---|---|---|---|---|---|---|---|---|---|
|Integrated inputs/outputs|16<br>16<br>16<br>32<br>32<br>32<br>32<br>32<br>32|||||||||
|Power supply<br>AC range(+10 %<br>Frequencyat AC<br>DC range(+20 %|+10 %,-15 %)<br>—<br>—<br>—<br>—<br>100–240 V<br>100–240 V<br>100–240 V<br>at AC<br>Hz<br>—<br>—<br>—<br>50/60<br>50/60<br>50/60<br>+20 %,-30 %)<br>24 V<br>24 V<br>24 V<br>—<br>—<br>—<br>W<br>25<br>25<br>25<br>25<br>25<br>25<br>24 V DC<br>50 A <0.5 ms<br>50 A <0.5 ms<br>50 A <0.5 ms<br>—<br>—<br>—<br>100 V AC<br>—<br>—<br>—<br>30 A <5 ms<br>30 A <5 ms<br>30 A <5 ms<br>200 V AC<br>—<br>—<br>—<br>65 A <5 ms<br>65 A <5 ms<br>65 A <5 ms<br>ower failure time<br>ms<br>5<br>5<br>5<br>10b<br>10b<br>10b<br>)<br>mA<br>—<br>—<br>—<br>310<br>310<br>310<br>mA<br>965<br>965<br>965<br>965<br>965<br>965|||||||||
|Max. input apparentpower||||||||||
|Inrush current at ON||||||||||
|Allowable momentary power failure time||||||||||
|External servicepower supply (24 V DC)||||||||||
|Power supplyint. bus(5 V DC)||||||||||
|**Inputs**||||||||||
|Integrated inputs|8<br>8<br>8<br>16<br>16<br>16<br>16<br>16<br>16|||||||||
|Input type|Sink/source<br>Sink/source<br>Sink/source<br>Sink/source<br>Sink/source<br>Sink/source<br>Sink/source<br>Sink/source<br>Sink/source|||||||||
|Input signal voltage|24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %<br>24 V DC<br>+20 %,-15 %|||||||||
|Min. current for logical 1|mA 3<br>3<br>3<br>3<br>3<br>3<br>3<br>3<br>3|||||||||
|Max. current for logical 0|mA 1.5<br>1.5<br>1.5<br>1.5<br>1.5<br>1.5<br>1.5<br>1.5<br>1.5|||||||||
|Response time|Hardware filter delay: ON: 50 µs or less; OFF: 150 µs or less<br>Digital filter settingvalue: 10 ms(initial value),adjustable from 10µs to 70 ms|||||||||
|**Outputs**||||||||||
|Integrated outputs|8<br>8<br>8<br>16<br>16<br>16<br>16<br>16<br>16|||||||||
|Output type|Relay<br>Transistor<br>(sink)<br>Transistor<br>(source)<br>Relay<br>Transistor<br>(sink)<br>Transistor<br>(source)<br>Relay<br>Transistor<br>(sink)<br>Transistor<br>(source)|||||||||
|Switching voltage (max.)|≤30 V DC,<br>≤240 V AC<br>5–30 V DC<br>5–30 V DC<br>≤240 V AC,<br>≤30 V DC<br>5–30 V DC<br>5–30 V DC<br>≤240 V AC,<br>≤30 V DC<br>5–30 V DC<br>5–30 V DC|||||||||
|Max. output<br>current<br>-per output<br>-pergroup*|A 2<br>0.5<br>0.5<br>2<br>0.5<br>0.5<br>2<br>0.5<br>0.5|||||||||
||A 8<br>0.8/1.6c<br>0.8/1.6c<br>8<br>0.8/1.6c<br>0.8/1.6c<br>8<br>0.8/1.6c<br>0.8/1.6c|||||||||
|Response time|ms 10<br>≤0.2<br>≤0.2<br>10<br>≤0.2<br>≤0.2<br>10<br>≤0.2<br>≤0.2|||||||||
|Life of contacts (switching times)a|3,000,000 at<br>20 VA; 1,000,000<br>at 35 VA; 200,000<br>at 80 VA<br>—<br>—<br>3,000,000 at<br>20 VA; 1,000,000<br>at 35 VA; 200,000<br>at 80 VA<br>—<br>—<br>3,000,000 at<br>20 VA; 1,000,000<br>at 35 VA; 200,000<br>at 80 VA<br>—<br>—|||||||||
|**Mechanical data**||||||||||
|Weight|kg 0.25<br>0.25<br>0.25<br>0.65<br>0.65<br>0.65<br>0.65<br>0.65<br>0.65|||||||||
|Dimensions (WxHxD)|mm 40x90x83<br>40x90x83<br>40x90x83<br>150x90x83<br>150x90x83<br>150x90x83<br>150x90x83<br>150x90x83<br>150x90x83|||||||||
1 Not guaranteed by Mitsubishi Electric
2 Adjustable from 10 to 100 ms when the supply voltage is 200 V AC
- 3 0.8 A for 4 outputs per group and 1.6 A for 8 outputs per group
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification..
50
I/O extension
~~**3**~~
## ~~**Unpowered extension modules**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Extension blocks FX2N**
**==> picture [95 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
OUT<br>OUT<br>IN<br>2<br>**----- End of picture text -----**<br>
The FX2N series modular extension blocks are available with 8 or 16 input/output points. It is possible to choose between relay and transistor output type.
- z LEDs for indicating the input and output status
- z MELSEC FX3G/FX3GC/FX3GE and FX3U series compatible
- z Very compact dimensions
- z Vertically terminal blocks with a cable guide to the upper or lower side
|**Electrical data**|**Electrical data**|
|---|---|
|rated inputs/outputs|8<br>8<br>8<br>8<br>16<br>16<br>16|
|Nbr. of occupied I/Opoints in the PLC|16<br>8<br>8<br>8<br>16<br>16<br>16|
|pply|All modular extension blocks are supplied bythe base unit.|
|||
|rated inputs|4<br>8<br>—<br>—<br>16<br>—<br>—|
|Min. current for logical 1<br>mA|3.5<br>3.5<br>—<br>—<br>3.5<br>—<br>—|
|Max. current for logical 0<br>mA|1.5<br>1.5<br>—<br>—<br>1.5<br>—<br>—|
|onse time|For all extension blocks of the MELSEC FX2N series: 10 ms(at time of shipment)|
|||
|rated outputs|4<br>—<br>8<br>8<br>—<br>16<br>16|
|Output type|Relay<br>—<br>Relay<br>Transistor<br>—<br>Relay<br>Transistor<br>(source)|
|gvoltage(max.)|Generallyfor relayversion: <240 V AC,<30 V DC;for transistor version: 5–30 V DC|
|Max. output current<br>-per output<br>A <br>-pergroup a<br>A|2<br>—<br>2<br>0.5<br>—<br>2<br>0.5|
||8<br>—<br>8<br>0.8<br>—<br>8<br>1.6|
|Max. switching power<br>- inductive load<br>VA|80<br>—<br>80<br>12<br>—<br>80<br>12|
|onse time<br>ms|10<br>10<br>10<br><0.2<br>—<br>10<br><0.2|
|Life of contacts(switchingtimes) b|For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA;1,000,000 at 35 VA;200,000 at 80 VA(for relayoutput only)|
|**Mechanical data**||
|kg|0.2<br>0.2<br>0.2<br>0.2<br>0.3<br>0.3<br>0.3|
|Dimensions (WxHxD)<br>mm|43x90x87<br>43x90x87<br>43x90x87<br>43x90x87<br>40x90x87<br>40x90x87<br>40x90x87|
1 This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
2 Not guaranteed by Mitsubishi Electric
Note: To connect these modules to a FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
51
I/O extension
~~**3**~~
## ~~**Unpowered extension modules**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
## **Input/output modules FX5 (terminal block type)**
The FX5 series I/O modules with terminal block can be connected to a FX5U CPU module directly. For the connection to a FX5UC CPU module a connector conversion module FX5-CNV-IFC or an extension power supply module FX5-C1PS-5V is required. Modules are available with 8 or 16 inputs/output points and relay or transistor output type.
The FX5-16ET/ES-H and the FX5-16ET-ESS-H are high-speed pulse input/output modules for frequencies up to 200 kpps.
- z LEDs for indicating the input and output status
- z MELSEC FX5U and FX5UC series compatible
- z Photocoupler isolation for input terminals and transistor outputs, mechanical isolation for relay outputs
- z Vertically terminal blocks with a cable guide to the upper or lower side
|**Specifications**<br>**High-speed pulse input/**<br>**output modules**|**Specifications**<br>**High-speed pulse input/**<br>**output modules**|**Input modules**|**Output modules**|**Output modules**|**Output modules**|**Output modules**|
|---|---|---|---|---|---|---|
|**Specifications**<br>**FX5-**<br>**16ET/ES-H**<br>**FX5-**<br>**16ET/ESS-H**||**FX5-**<br>**8EX/ES**<br>**FX5-**<br>**16EX/ES**|**FX5-**<br>**8EYR/ES**<br>**FX5-**<br>**8EYT/ES**<br>**FX5-**<br>**8EYT/ESS**<br>**FX5-**<br>**16EYR/ES**<br>**FX5-**<br>**16EYT/ES**<br>**FX5-**<br>**16EYT/ESS**||||
|**Electrical data**|||||||
|Integrated inputs/outputs|16<br>16|8<br>16|8<br>8<br>8<br>16<br>16<br>16||||
|Power supply<br>5 V DC<br>24 V DC|Supplied internally|Supplied internally|Supplied internally||||
||Supplied from service power<br>supplyor externalpower supply|Supplied from service power<br>supplyor externalpower supply|Supplied internally||||
|Current consumption<br>5 V DC<br>mA <br>24 V DC<br>mA|100<br>100|75<br>100|75<br>75<br>75<br>100<br>100<br>100||||
||125(82a)<br>125(82a)|50<br>85|75<br>75<br>75<br>125<br>125<br>125||||
|**Inputs**|||||||
|Integrated inputs|8<br>8|8<br>16|—||||
|Input type|Sink/source<br>Sink/source|Sink/source<br>Sink/source|||||
|Input signal voltage|24 V DC +20 %,-15 %|24 V DC +20 %,-15 %|||||
|Min. current for logical 1<br>mA|3.5<br>3.5|3.0<br>3.0|||||
|Max. current for logical 0<br>mA|1.5<br>1.5|1.5<br>1.5|||||
|Response time|X0 to X5:<br>ON: ≤2.5 µs; OFF: ≤2.5 µs<br>X6, X7:<br>ON: ≤30µs;OFF: ≤50µs|ON: ≤50 µs; OFF: ≤150 µs|||||
|**Outputs**|||||||
|Integrated outputs|8<br>8|—|8<br>8<br>8<br>16<br>16<br>16||||
|Output type|Transistor<br>(sink)<br>Transistor<br>(source)||Relay<br>Transistor<br>(sink)<br>Transistor<br>(source)<br>Relay<br>Transistor<br>(sink)<br>Transistor<br>(source)||||
|Switching voltage (max.)|5–30 V DC<br>5–30 V DC||≤240 V AC,<br>≤30 V DC<br>5–30 V DC<br>5–30 V DC<br>≤240 V AC,<br>≤30 V DC<br>5–30 V DC<br>5–30 V DC||||
|Max. output current<br>-per output<br>A <br>-pergroup*<br>A|0.5<br>0.5||2<br>0.5<br>0.5<br>2<br>0.5<br>0.5||||
||1.6b<br>1.6b||8<br>0.8c<br>0.8c<br>8<br>1.6b<br>1.6b||||
|Response time<br>ms|Y0, Y1, Y4, Y5: ≤2.5 µs<br>Y2, Y3, Y6, Y7: ≤0.2 ms||3,000,000<br>at 20 VA;<br>1,000,000<br>at 35 VA;<br>200,000<br>at 80 VA<br>—<br>—<br>3,000,000<br>at 20 VA;<br>1,000,000<br>at 35 VA;<br>200,000<br>at 80 VA<br>—<br>—||||
|**Mechanical data**|||||||
|Weight<br>kg|0.25<br>0.25|0.25<br>0.25|0.2<br>0.2<br>0.2<br>0.25<br>0.25<br>0.25||||
|Dimensions (WxHxD)<br>mm|40x90x83<br>40x90x83|40x90x83<br>40x90x83|40x90x83<br>40x90x83<br>40x90x83<br>40x90x83<br>40x90x83<br>40x90x83||||
1 Current consumption when external power supply is used for the input circuit.
2 1.6 A for 8 outputs per group
3 0.8 A for 4 outputs per group
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
52
I/O extension
~~**3**~~
## ~~**Unpowered extension modules**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
## **Input/output modules FX5 (connector type)**
The connector type FX5 series I/O modules can be directly connected to an FX5UC CPU module. For the connection to an FX5U CPU module a connector conversion module FX5-CNV-IF is required. Modules are available with 16 or 32 inputs/output points.
- z Very compact dimensions
- z LEDs for indicating the input and output status
- z MELSEC FX5U and FX5UC series compatible
- z Photocoupler isolation for input terminals and transistor outputs
- z Terminal modules for the conversion of connector-type I/O terminals into terminal blocks are available
|**Specifications**<br>**FX5-**<br>**C32ET/D**<br>**FX5-**<br>**C32ET/DSS**|**Specifications**<br>**FX5-**<br>**C32ET/D**<br>**FX5-**<br>**C32ET/DSS**|**FX5-**<br>**C16EX/D**<br>**FX5-**<br>**C16EX/DS**<br>**FX5-**<br>**C32EX/D**<br>**FX5-**<br>**C32EX/DS**|**FX5-**<br>**C16EYT/D**<br>**FX5-**<br>**C16EYT/DSS**<br>**FX5-**<br>**C32EYT/D**<br>**FX5-**<br>**C32EYT/DSS**|**FX5-**<br>**C16EYT/D**<br>**FX5-**<br>**C16EYT/DSS**<br>**FX5-**<br>**C32EYT/D**<br>**FX5-**<br>**C32EYT/DSS**|**FX5-**<br>**C16EYT/D**<br>**FX5-**<br>**C16EYT/DSS**<br>**FX5-**<br>**C32EYT/D**<br>**FX5-**<br>**C32EYT/DSS**|**FX5-**<br>**C16EYT/D**<br>**FX5-**<br>**C16EYT/DSS**<br>**FX5-**<br>**C32EYT/D**<br>**FX5-**<br>**C32EYT/DSS**|
|---|---|---|---|---|---|---|
|**Electrical data**|||||||
|Integrated inputs/outputs|32<br>32|16<br>16<br>32<br>32|16<br>16<br>32<br>32||||
|Power supply<br>5 V DC<br>24 V DC|Supplied internally|Supplied internally|Supplied internally||||
||Input connector:<br>Supplied from service power<br>supply or external power supply<br>Output connector:<br>Supplied internally|Supplied from service power supply or external power supply|Supplied internally||||
|Current consumption<br>5 V DC<br>24 V DC|mA 120<br>120|100<br>100<br>100<br>100|100<br>100<br>120<br>120||||
||mA Input connector: 65<br>Output connector: 100a|65<br>65<br>130<br>130|100<br>100<br>200<br>200||||
|**Inputs**|||||||
|Integrated inputs|16<br>16|16<br>16<br>32<br>32|—||||
|Input type|Sink<br>Sink/source|Sink<br>Sink/source<br>Sink<br>Sink/source|||||
|Input signal voltage|24 V DC +20 %,-15 %|24 V DC +20 %,-15 %|||||
|Min. current for logical 1|mA 3.0<br>3.0|3.0<br>3.0<br>3.0<br>3.0|||||
|Max. current for logical 0|mA 1.5<br>1.5|1.5<br>1.5<br>1.5<br>1.5|||||
|Response time|ON: ≤50µs;OFF: ≤150µs|ON: ≤50µs;OFF: ≤150µs|||||
|**Outputs**|||||||
|Integrated outputs|16<br>16|—|16<br>16<br>32<br>32||||
|Output type|Transistor<br>(sink)<br>Transistor<br>(source)||Transistor<br>(sink)<br>Transistor<br>(source)<br>Transistor<br>(sink)<br>Transistor<br>(source)||||
|Switchingvoltage(max.)|5–30 V DC<br>5–30 V DC||5–30 V DC<br>5–30 V DC<br>5–30 V DC<br>5–30 V DC||||
|Max. output current<br>-per output<br>-pergroup*|A 0.1<br>0.1||0.1<br>0.1<br>0.1<br>0.1||||
||*<br>A 0.8 b<br>0.8 b||0.8 b<br>0.8 b<br>0.8 b<br>0.8 b||||
|Response time|ms ≤0.2 ms<br>≤0.2 ms||≤0.2<br>≤0.2<br>≤0.2<br>≤0.2||||
|**Mechanical data**|||||||
|Weight|kg 0.15<br>0.15|0.1<br>0.1<br>0.15<br>0.15|0.1<br>0.1<br>0.15<br>0.15||||
|Dimensions (WxHxD)|mm 20.1x90x53<br>20.1x90x53|14.6x90x53<br>14.6x90x53<br>20.1x90x53<br>20.1x90x53|14.6x90x53<br>14.6x90x53<br>20.1x90x53<br>20.1x90x53||||
1 Current consumption when external power supply is used for the input circuit.
2 0.8 A per COM /+V terminal
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
53
I/O extension
## ~~**Unpowered extension modules**~~
## ¨ **FX3S** ¨ **FX3G** þ **FX3GC** ¨ **FX3GE** ¨ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
~~**3**~~
**==> picture [105 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
NNTISN <> FX2NC-16EYR-T-DS<br>FX2NC-DS -32EX<br>PWY0Y4Y0Y4123567123567<br>POWERX0X4X0X4123567123567 X0X4X0X4123567123567<br>**----- End of picture text -----**<br>
The modular extension units of the FX2NC series can be used in combination with FX3GC or FX3UC series base units. They are available with 16 or 32 input/output points. For modules with 16 outputs it is possible to choose between relay and transistor output type.
- z Very compact dimensions
- z LEDs for indicating the input and output status
- z Removable terminal blocks for
- FX2NC-16EYR-T-DS and FX2NC-16EX-T-DS (interchangeable against optional spring terminal blocks)
- z Adapter modules and system cabling sets are optionally available for units with ribbon cable connectors (transistor output types)
|**Electrical data**|**Electrical data**|
|---|---|
|Integrated inputs/outputs|16<br>16<br>16<br>16<br>32<br>32|
|Power supply|All modular extension blocks are supplied bythe base unit.|
|**Inputs**||
|Integrated inputs|16<br>—<br>16<br>—<br>32<br>—|
|Input current X0→X7 / X10→∞|7/5<br>—<br>7/5<br>—<br>7/5<br>—|
|Min. current for logical 1<br>X0→X7/X10→∞<br>mA|mA 4.5/3.5<br>—<br>4.5/3.5<br>—<br>4.5/3.5<br>—|
|Max. current for logical 0<br>mA|mA 1.5<br>—<br>1.5<br>—<br>1.5<br>—|
|Isolation|Photocoupler isolation between input terminals and PCpower for all base units|
|Response time|For all extension units of the MELSEC FX2NC series: 10 ms(at time of shipment), partlyadjustable between 0 and 60 ms in 1 ms steps(REFF,FNC51 = 0–60 ms)|
|**Outputs**||
|Integrated outputs|—<br>16<br>—<br>16<br>—<br>32|
|Output type|—<br>Relay<br>—<br>Transistor<br>—<br>Transistor|
|Switchingvoltage(max.)|V Generallyfor relayversion: <240 V AC,<30 V DC;for transistor version: 5–30 V DC|
|Max. output<br>current<br>-per output<br>-pergroup*|A —<br>2<br>—<br>0.1/0.3a<br>—<br>0.1/0.3a|
||A —<br>4/8<br>—<br>0.8<br>—<br>0.8|
|Max. switching<br>power<br>- inductive load<br>VA<br>- lampload<br>W|VA —<br>80<br>—<br>2.4/7.2b<br>—<br>2.4/7.2b|
||W —<br>100<br>—<br>0.3/0.9c<br>—<br>0.3/0.9c|
|Response time<br>ms|ms —<br>10<br>—<br><0.2<br>—<br><0.2|
|Life of contacts(switchingtimes)|—<br>like base unit<br>—<br>—<br>—<br>—|
|**Mechanical data**||
|Connection type|Removable screw terminal blocks<br>Ribbon cable connector<br>Ribbon cable connector<br>Ribbon cable connector<br>Ribbon cable connector|
|Weight<br>k|kg 0.2<br>0.2<br>0.15<br>0.2<br>0.2<br>0.2|
|Dimensions (WxHxD)<br>mm|mm 20.2x90x89<br>24.2x90x89<br>14.6x90x87<br>14.6x90x87<br>26.2x90x87<br>26.2x90x87|
a 0.3 A for Y0 to Y1; 0.1 A all others b 7.2 W for Y0 to Y3; 2.4 W all others c 0.9 W for Y0 to Y3; 0.3 W all others
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
Note: These modules can be combined with PLC base units of the FX3GC or FX3UC series!
54
Analog modules
~~**4**~~
## ~~**Analog input modules**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
The analog input modules provide the user with 2 to 8 analog inputs.
The module converts analog process signals into digital values which are further processed by the base unit.
The actual values or mean values over several measurements may be output.
The FX5-8AD supports the logging function for up to 10.000 values per channel and the offset/ gain adjustment via the programming software.
**==> picture [24 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
2N-2AD<br>POWER<br>FX<br>**----- End of picture text -----**<br>
|Applicable for|Base units<br>FX3G/FX3GC/FX3GE/<br>FX3U/FX3UC<br>Base units<br>FX3G/FX3GC/FX3GE/<br>FX3U/FX3UC/<br>FX5U/FX5UC<br>Base units<br>FX3G/FX3GC/FX3GE/<br>FX3U/FX3UC<br>Base units<br>FX3G/FX3GC/FX3GE/<br>FX3U/FX3UC/FX5U/<br>FX5UC<br>Base units FX5U/<br>FX5UC|
|---|---|
|Analog channels<br>Inputs<br>Outputs|2<br>4<br>4<br>8<br>8|
||—<br>—<br>—<br>—<br>—|
|Analog input range|0–+10 V DC/<br>0–+5 V DC/<br>0/4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>Temperature detec-<br>tor (K, J, T, B, R, S,<br>Pt100,Ni100) 2|
|Resolution<br>Voltage<br>Current|2.5 mV, 1.25 mV/<br>4 µA (12 bit)<br>0.32 mV<br>(16 bit + sign)<br>0.32 mV<br>(16 bit + sign)<br>0.63 mV<br>(14 bit + sign)<br>0.3125 mV<br>(16 bit + sign)<br>1.25 µA<br>(15 bit + sign)<br>1.25 µA<br>(15 bit + sign)<br>2.5 µA<br>(13 bit + sign)<br>0.625 µA<br>(16 bit + sign)|
|Fullscale overall accuracy|±1 %<br>±0.3–1 %1<br>±0.3–1 %1<br>±0.3–0.5 %1<br>±0.3–±0.5 %|
|Power supply<br>5 V DC<br>24 V DC|20 mA<br>(from base unit)<br>110 mA<br>(from base unit)<br>100 mA<br>(from base unit)<br>50 mA<br>(from base unit)<br>—|
||50 mA<br>(from base unit)<br>90 mA<br>80 mA<br>80 mA<br>100 mA<br>(from external)<br>40 mA<br>(from base unit)|
|Related I/Opoints|8<br>8<br>8<br>8<br>8|
|Weight<br>kg|0.3<br>0.2<br>0.13<br>0.4<br>0.3|
|Dimensions (WxHxD)<br>mm|43x90x87<br>55x90x87<br>20.2x90x79<br>75x105x75<br>50x90x83|
1 Dependent on the ambient temperature
2 Please refer to manuals for further details of specification of temperature detectors.
Notes: The FX2N-8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type thermocouples. To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Analog output modules**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
**==> picture [36 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
24 V<br>D/A<br>FX -4DA3U<br>**----- End of picture text -----**<br>
The analog output modules provide the user with 2 to 4 analog outputs. The modules convert digital values from the FX3G/FX3GC/FX3GE/
FX3U/FX3UC controller to the analog signals required by the process. The module can output both current and voltage signals.
|Applicable for|Base units<br>FX3G/FX3GC/FX3GE/FX3U/FX3UC<br>Base units<br>FX3G/FX3GC/FX3GE/FX3U/FX3UC/FX5U/FX5UC|
|---|---|
|Analog channels<br>Inputs<br>Outputs|—<br>—|
||2<br>4|
|Analog output range|0–+10 V DC/<br>0–+5 V DC/<br>4–+20 mA<br>-10–+10 V DC/<br>0–+20 mA/<br>4–+20 mA|
|Resolution<br>Voltage<br>Current|2.5 mV(12 bit)<br>0.32 mV(16 bit + sign)|
||4µA(12 bit)<br>0.63µA(15 bit)|
|Fullscale overall accuracy|±1 %<br>±0.3–0.5 %*|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)<br>—|
||85 mA(from base unit)<br>160 mA|
|Related I/Opoints|8<br>8|
|Weight<br>kg|0.3<br>0.2|
|Dimensions(WxHxD)<br>mm|43x90x87<br>55x90x87|
* Dependent on the ambient temperature
Note: To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
55
Analog modules
~~**4**~~
## ~~**Combined analog I/O module**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The analog input/output module provides the For the analog inputs it can be selected between user with 4 analog inputs and 1 analog output. current or voltage input signal. It serves for conversion of analog process signals into digital values, and vice versa.
**==> picture [66 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
= 24 V<br>AD / DA<br>FX -5A2N<br>**----- End of picture text -----**<br>
|**Specifications**<br>Analog channels<br>Input<br>(resolution)|Inputs<br>Outputs<br>Voltage<br>Current||**FX2N-5A**<br>4<br>1<br>-10–+10 V (15 bit + sign),<br>-100–+100 mV(11 bit + sign)<br>-20–+20 mA (14 bit + sign),<br>0/4–+20 mA(14 bit)|
|---|---|---|---|
|Output<br>(resolution)|Voltage<br>Current||-10–+10 V(12 bit)<br>0/4–+20 mA(10 bit)|
|Fullscale overall accuracy|||±0.3–1 %*|
|Power supply<br>Related I/Opoints<br>Weight<br>Dimensions(WxHxD)<br>**Order information**|5 V DC<br>24 V DC|kg <br>mm <br>Art. no.|70 mA(from base unit)<br>90 mA<br>8<br> 0.3<br> 55x90x87<br> 153740|
Note: To connect the module to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
56
Analog modules
~~**4**~~
## ~~**Analog temperature input adapters**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The analog input adapters for thermocouples are used for processing temperatures. They have 4 independent inputs for detecting signals from thermocouples of various types. thermometers to the PLC system.
The FX3U/FX5U-4AD-PT-ADP, FX3U-4AD-PTW-ADP and FX3U-4AD-PNK-ADP analog input adapters enable the connection of up to four resistance
|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|**Specifications**<br>**FX3U-4AD-**<br>**TC-ADP**<br>**FX3U-4AD-**<br>**PT-ADP**<br>**FX3U-4AD-**<br>**PTW-ADP**<br>**FX3U-4AD-**<br>**PNK-ADP**<br>**FX5-4AD-**<br>**PT-ADP**<br>**FX5-4AD-**<br>**TC-ADP**<br>Applicable for<br>Base units FX3S,FX3G,FX3GC,FX3GE,FX3U,FX3UC<br>Base units FX5U,FX5UC<br>Analog inputs<br>4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or<br>Ni1000)<br>4<br>4<br>Compensated temperature range °C -100–+600 (J)/<br>-100–+1000 (K)<br>-50–+250<br>-100–+600<br>-50–+250<br>(Pt1000)/<br>-40–+110<br>(Ni1000)<br>-200–+850<br>(Pt100)/<br>-60–+250<br>(Ni100)<br>-40–+750(J)/<br>-200–+1200 (K)/<br>0–1600(R, S)<br>Digital outputs<br>-1000–+6000 (J)/<br>-1000–+10000 (K) -500–+2500 -1000–+6000<br>-500–+2500<br>(Pt1000)/<br>-400–+1100<br>(Ni1000)<br>-2000–+8500<br>(Pt100)/<br>-600–+2500<br>(Ni100)<br>-400–+7500 (J)/<br>-2000–+12000 (K)/<br>0–16000 (R, S)<br>Resolution<br>°C 0.3 (J)/0.4 (K)<br>0.1<br>0.2–0.3<br>0.1<br>0.1<br>0.1 (K,J,T),<br>0.1–0.3(B,R,S)<br>Fullscale overall accuracy<br>±0.5 % (fullscale) ±0.5–1.0 % (fullscale)*<br>±0.4–2.4 °C<br>(fullscale)*<br>±2.8–7.2 °C<br>(fullscale)*<br>Power supply<br>5 V DC<br>15 mA<br>(from base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>15 mA (from<br>base unit)<br>10 mA<br>10 mA<br>24 V DC<br>45 mA<br>50 mA<br>50 mA<br>50 mA<br>20 mA<br>20 mA<br>Related I/Opoints<br>0<br>0<br>0<br>0<br>0<br>0<br>Weight<br>kg 0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>0.1<br>FX3U-4AD-TC-ADP<br>FX3U-4AD-PT-ADP<br>~~ee~~<br>i<br>ih [;|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||||||||||Dimensions(WxHxD)<br>mm 17.6x90(106)x89.5<br>17.6x90(106)x74(89.1)|
|||||||||||||||||||||||||
||||||||||||||||||||||||**Order information**<br>Art. no. 165273<br>165272<br>214173<br>214172<br>304298<br>304299|
* Dependent on the ambient temperature
Notes: When connecting the FX3 analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.
## ~~**Analog I/O adapters**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The analog input adapter FX3U-4AD-ADP is mounted on the left side of the base unit and extends a controller of the FX3 series with 4 analog inputs.
The analog input/output module FX3U-3A-ADP provides the user with two analog inputs and one analog output.
The analog output adapter FX3U-4DA-ADP is mounted on the left side of a FX3 series base unit and provides four analog outputs.
FX3U-4AD-ADP
FX3U-4DA-ADP
|Analog channels<br>Inputs<br>Outputs<br>~~ee~~|4<br>—<br>2<br>~~ee~~|
|---|---|
||—<br>4<br>1|
|Analogrange|0–+10 V DC,4–+20 mA<br>0–+10 V DC,4–+20 mA<br>0–+10 V CC,4–+20mA|
|Resolution|2.5 mV/10µA(12 bit/11 bit)<br>2.5 mV/4µA(12 bit)<br>2.5 mV/4μA(12 bit)|
|Overall accuracy|±0.5 % */±1 %<br>±0.5 % */±1 %<br>±0.5–1 %*|
|Power supply<br>5 V DC<br>24 V DC|15 mA(from base unit)<br>15 mA(from base unit)<br>20 mA(from base unit)|
||40 mA<br>150 mA<br>90 mA|
|Related I/Opoints|0<br>0<br>0|
|Weight<br>kg|0.1<br>0.1<br>0.1|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x89.5<br>17.6x90(106)x89.5<br>17.6x90x89.5|
* Dependent on the ambient temperature and signal quality
Notes: When connecting the analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.
57
Analog modules/Temperature control module
~~**4** a~~ NX NF FX5-4AD-ADP
## ~~**Analog I/O adapters**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
Up to four analog expansion adapters can be A FX5-4AD-ADP provides four analog inputs and mounted on the left side of a FX5U CPU module a FX5-4DA-ADP provides four analog outputs. or FX5UC CPU module.
|Analog channels<br>Inputs<br>Outputs|4<br>—|
|---|---|
||—<br>4|
|Analogrange|-10–+10 V DC,-20–+20 mA<br>-10–+10 V DC,0–+20 mA|
|Resolution|312.5µV/1.125μA(14 bit)<br>250µV/1μA(14 bit)|
|Overall accuracy|±0.1 % */±0.3 %<br>±0.1 % */±0.2 %|
|Power supply<br>5 V DC<br>24 V DC|10 mA(from base unit)<br>10 mA(from base unit)|
||20 mA(from base unit)<br>160 mA(externalpower supply)|
|Related I/Opoints|0<br>0|
|Weight<br>kg|0.1<br>0.1|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x89.1<br>17.6x90(106)x89.1|
* Dependent on the ambient temperature and signal quality
FX5-4DA-ADP
## ~~**Temperature control modules**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
**==> picture [63 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX -4LC<br>24 V<br>OUT1<br>OUT2<br>OUT3<br>OUT4<br>3U<br>**----- End of picture text -----**<br>
The temperature control module FX3U-4LC is equipped with four temperature input points and four transistor (open collector) output points. It is used to read temperature signals from thermocouples and Pt100 sensors, and performs PID output control.
The channels are isolated against each other. Self-diagnosis functions are provided, and the disconnection of heaters can be detected by current detection (CT).
The temperature control module FX5U-4LC supports parameter transfer/automatic refreshing. The spring clamp terminal enables compact size
The proportional band, the integral time and the derivative time can be easily set by auto tuning. and enhances vibration resistance.
|Applicable for|Base units FX3G, FX3GC, FX3GE, FX3U, FX3UC,<br>FX5U,FX5UC<br>Base units FX5U, FX5UC|
|---|---|
|Analoginputs|4(Thermocouple and Pt100 sensors)<br>4(Thermocouple,Pt100 and Pt1000 sensors)|
|Compensated temperature range<br>°C|-200–+2300<br>-200–+2300|
|Digital outputs|4 NPN transistor open collector outputpoints<br>4 NPN transistor open collector outputpoints|
|Resolution<br>°C|0.1 or 1<br>0.1 or 1|
|Fullscale overall accuracy|±0.3–0.7 %(fullscale,dependent on the ambient temperature)|
|Power supply<br>5 V DC<br>24 V DC|160 mA(from base unit)<br>140 mA(from base unit)|
||50 mA<br>25 mA|
|Related I/Opoints|8<br>8|
|Dimensions (WxHxD)<br>mm|90x90x86<br>60x90x83|
Note: To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
58
Data logger/High-speed counter modules
## ~~**Data logger module**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
Another usage is the storage of bigger recipe data. A CompactFlash memory card up to 2 GB can be used. Six applied instructions allow all kinds of data writing, manipulation or reading, making this adapter the optimum solution
The FX3U-CF-ADP is a general purpose data logging adapter. The difference to other available logging units is that the PLC main unit controls the data logging based on user requirements, e.g. periodical or even based. For tracing a timestamp is automatically added to all data towards customer requirements. storages, that eases alarm and other time critical logging.
**==> picture [48 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-CF-ADPPOWER CF CARDFULL ACCESSON<br>BUFFER ACCESS<br>ERR. SLOT OFF<br>**----- End of picture text -----**<br>
**==> picture [410 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|logging.|
|Specifications|FX3U-CF-ADP|
|Data access method|Controlled by the main unit, no polling from the logging unit possible.|
|Connectable units|A maximum of one FX3U-CF-ADP can be connected per PLC.|
|||ee|Time stamp function|The real time clock data of the base unit is used.|
|Recommended storage media|CompactFlash memory card (GT05-MEM-256MC, -512MC, -1GC, -2GC)|
|Max. file size|512 MB|
|File format|CSV|
|Max. numbers of files|63 (Plus one FIFO file.)|
|FIFO function|One pattern (The file name gets automatically|generated.)|
|Power supply|24 V DC|130 mA|
|Related I/O points|kg|0|
|Dimensions (WxHxD)|mm|45x90x89.5|
|Order information|Art. no.|230104|
**----- End of picture text -----**<br>
~~**4**~~
## ~~**High-speed counter modules**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
In addition to the internal high-speed MELSEC The two integrated transistor outputs can be FX counters, the high-speed counter modules switched independently of one another by FX2N-1HC, FX2NC-1HC and FX3U-2HC provide means of internal comparison functions. Hence, the user with an external counter. It counts 1- or simple positioning tasks can also be realized 2-phase pulses up to a frequency of 200 kHz. economically. In addition, the modules can be The counting range covers either 16 or 32 bit. used as a ring counter.
**==> picture [23 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX -1HC2N<br>**----- End of picture text -----**<br>
**==> picture [337 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|a|Specifications|FX2N-1HC|FX2NC-1HC *|FX3U-2HC|
|Base units|Base units|Base units|
|Applicable for|FX3U/FX3UC|FX3U/FX3UC|FX3U/FX3UC/FX5U/FX5UC|
|Counter inputs|2 (1 phase) or 1 (2 phase)|2 (1 phase) or 1 (2 phase)|2 (1 phase) or 1 (2 phase)|
|Max. counting frequency|kHz|50|50|200/100/50|
|Signal level|5, 12, 24 V DC/7 mA|5, 12, 24 V DC/7 mA|5, 12, 24 V DC|
|Input format|bit|16, 32|16, 32|—|
|Type of counter|Up/down counter, ring counter|Up/down counter, ring counter|Up/down counter, ring counter|
|16 bit|0–65535|0–65535|0–65535|
|Counting range|
|32 bit|-2147483648–+2147483647|-2147483648–+2147483647|-2147483648–+2147483647|
|Output type|2 x transistor (5–24 V DC; 0.5 A)|2 x transistor (5–24 V DC; 0.5 A)|2 x transistor (5–24 V DC; 0.5 A)|
|5 V DC|90 mA (from base unit)|90 mA (from base unit)|24 mA (from base unit)|
|Power supply|24 V DC|—|—|—|
|Related I/O points|8|8|8|
|Weight|kg|0.3|0.13|0.08|
|Dimensions (WxHxD)|mm|55x90x87|20.2x90x89|55x90x87|
|Order information|Art. no.|65584|217916|232805|
**----- End of picture text -----**<br>
* The FX2NC 1HC can only be connected to a FX3UC base unit.
59
High-speed counter/Positioning modules
## ~~**High-speed counter adapters**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
~~**4**~~
These adapter modules allow direct processing of positioning application data.
The FX3U-4HSX-ADP provide high speed counter inputs up to 200 kHz while the FX3U-2HSYADP delivers 2 channels of pulse train outputs up to 200 kHz.
|**Specifications**<br>**FX3U-4HSX-ADP**<br>**FX3U-2HSY-ADP**<br>Maximum connectivity<br>2<br>2<br>~~ee~~|**Specifications**<br>**FX3U-4HSX-ADP**<br>**FX3U-2HSY-ADP**<br>Maximum connectivity<br>2<br>2<br>~~ee~~|**Specifications**<br>**FX3U-4HSX-ADP**<br>**FX3U-2HSY-ADP**<br>Maximum connectivity<br>2<br>2<br>~~ee~~|**Specifications**<br>**FX3U-4HSX-ADP**<br>**FX3U-2HSY-ADP**<br>Maximum connectivity<br>2<br>2<br>~~ee~~|
|---|---|---|---|
|Counter<br>Inputs<br>Outputs||4<br>—|—<br>2|
|Max. counting<br>frequency<br>Inputs<br>kHz<br>Outputs<br>kHz||1 ch 1 input or<br>1 ch 2 inputs: 200<br>2 ch 2 inputs: 100<br> —|—<br>200|
|Input format||Differential line receiver (AM26C32 is suitable)<br>Photocoupler isolation on inputs<br>—||
|Output format||—|Differential line driver (AM26C31 is suitable)<br>Normal rotation pulse train, reverse pulse train<br>orpulse train + direction signal|
|Maximum cable length<br>m||10|10|
|Inputpotential||5 V DC|—|
|Output load||—|less than 25 mA|
|Power supply<br>5 V DC<br>24 V DC||30 mA(from base unit)<br>30 mA(from base unit)|30 mA(from base unit)<br>60 mA(from base unit)|
|Related I/Opoints||0|0|
|Weight<br>kg||0.08|0.08|
|Dimensions(WxHxD)<br>mm||17.6x90(106)x89.5|17.6x90(106)x89.5|
|||||
|**Order information**<br>Art. no.||165274|165275|
|Note: The adapters FX3U-m-ADP can only be used with the FX3U and they require a function extension board.||||
|~~**Single-axis positioning modules**~~||||
|¨**FX3S**¨**FX3G**¨**FX3GC**¨**FX3GE**|||**FX3GE**þ**FX3U**þ**FX3UC**þ**FX5U**þ**FX5UC**|
|The positioning modules FX3U-1PG, FX2N-10PG|||The configuration and allocation of the posi-|
|and FX5-20PG-P are extremely efficient position-<br>ing modules for controlling either step drives<br>or servo drives (by external regulator) with a<br>pulse chain. They are very suitable for achieving<br>accurate positioning in combination with the<br>MELSEC FX series.<br>**Specifications**<br>**FX3U-1PG**<br>Applicable for<br>Base units FX3U/FX3UC/<br>FX5U/FX5UC<br>~~ee~~|||tion data are carried out directly via the PLC<br>program. A very wide range of manual and<br>automatic functions are available to the user.<br>**FX2N-10PG**<br>**FX5-20PG-P**<br>Base units FX3U/FX3UC<br>Base units FX5U/FX5UC<br>~~ee~~|
|Accessible axes||1|1<br>2|
|Output frequency<br>pulses/s||10–200 000|1–1 000 000<br>1–200 000|
|Signal level for digital inputs||24 V DC/40 mA|5 V DC/100 mA;<br>24 V DC/70 mA<br>24 V DC/5 mA|
|Power supply<br>5 V DC<br>24 V DC||150 mA(from base unit)<br>—|120 mA(from base unit)<br>—<br>—<br>120 mA(from base unit)|
|Related I/Opoints||8|8<br>8|
|Weight<br>kg||0.3|0.2<br>0.2|
|Dimensions(WxHxD)<br>mm||43x90x87|43x90x87<br>50x90x83|
|||||
|**Order information**<br>Art. no.||259298|140113<br>312301|
FX3U-4HSX-ADP
FX3U-2HSY-ADP
## ~~**Single-axis positioning modules**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
The positioning modules FX3U-1PG, FX2N-10PG The configuration and allocation of the posiand FX5-20PG-P are extremely efficient positiontion data are carried out directly via the PLC ing modules for controlling either step drives program. A very wide range of manual and or servo drives (by external regulator) with a automatic functions are available to the user. pulse chain. They are very suitable for achieving accurate positioning in combination with the ii MELSEC FX series. **Specifications FX3U-1PG FX2N-10PG FX5-20PG-P** ~~ee~~
60
Positioning module/Simple Motion modules
~~**4**~~
## ~~**Positioning module for SSCNETIII**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
**==> picture [37 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
o Hes" Cea<br>**----- End of picture text -----**<br>
The SSCNET module FX3U-20SSC-H can be used in combination with a FX3U or FX3UC programmable controller to achieve a cost effective solution for high precision, high speed positioning. The plug-and-play fiber optic SSCNET cabling reduces setup time and increases control distance for positioning operations in a wide range of applications.
Servo parameters and positioning information for the FX3U-20SSC-H are easily set up with an FX3U/FX3UC base unit and a personal computer. For parameter setting, monitoring and testing the easy programming software FX Configurator-FP is available.
|**Specifications**||**FX3U-20SSC-H**|
|---|---|---|
|Accessible axes||2(independent or interpolation)|
|Output frequency||1 Hz to 50 MHz|
|Pulse output format<br>Communications speed||SSCNETIII(servo bus)<br>50 Mbps|
|Startingtime|ms|1.6(+1.7 SSCNET cycle time)|
|Max. to PLC connectable modules<br>Status displays<br>Power supply<br>5 V DC<br>24 V DC<br>Related I/Opoints<br>Weight<br>kg <br>Dimensions (WxHxD)<br>mm <br>**Order information**<br>Art. no.||Upto 8 can be connected to the FX3U PLC<br>Power,module status,axis status,error<br>100 mA<br>—<br>8<br> 0.3<br> 55x90x87<br> 231512|
Notes: The FX3U-20SSC-H can be used in combination with a FX3U or FX3UC base unit only. Please refer to the Mitsubishi Electric MELSERVO catalog for suitable servo motors and amplifiers.
## ~~**Simple Motion modules**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
The FX5-40SSC-S 4-axis and FX5-80SSC-S 8-axis Simple Motion modules complement the built-in positioning function of the FX5U or FX5UC* base unit. Similar to positioning modules, these Simple Motion modules are capable of a wide range of high-precision controls, such as positional control, advanced synchronous control, cam control and speed and torque control with setup of even complex motion control functions being done easily by parameters and programming.
The standard encoder signal interface and highspeed inputs for mark detection, for example, enable the system to be used in classical serial machines such as packaging and bottling lines or palletising systems without fitting additional optional modules. A function for automatically calculating the cam data for a rotary cutter application simply by entering the product length and the synchronization width is also included.
* For the connection to a FX5UC CPU module a connector conversion module FX5-CNV-IFC or an extension power supply module FX5-C1PS-5V is required.
|Number of controllable axes|4<br>8|
|---|---|
|Interpolation functions|Linear interpolation for upto 4 axes,circular interpolation for 2 axes|
|Control system|PTP (Point To Point) control, Trajectory control (both linear and arc), Speed control,<br>Speed-position switchingcontrol,Position-speed switchingcontrol,Speed-torque control|
|Mark detection function|Regular mode, Specified Number of Detections mode, Ring Buffer mode;<br>Mark detection signal: upto 4points,mark detection setting: 16 settings|
|Servo amplifier connection method|SSCNETIII/H<br>SSCNETIII/H|
|Servo amplifier|MR-JE-B/MR-J4-B/MR-J4W2-B/MR-J4W3-B servo amplifier range|
|Operation cycle|1.77 ms<br>1.77 ms|
|Power supply<br>5 V DC<br>24 V DC|—<br>—|
||250 mA<br>250 mA|
|Related I/Opoints|8<br>8|
|Weight<br>kg|0.3<br>0.3|
|Dimensions (WxHxD)<br>mm|50x90x83<br>50x90x83|
61
Network modules
~~**4** a~~
## ~~**Network modules for CC-Link**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
**==> picture [84 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
T=<br>POWER<br>FX3U-16CCL-M<br>RUN<br>ERR.<br>L RUN<br>L ERR.<br>SD<br>RD<br>**----- End of picture text -----**<br>
## **CC-Link master module**
The setting of all modules within the network is handled directly via the master module. The maximum communications distance is 1200 m without repeater.
The CC-Link network enables the controlling and monitoring of decentralized I/O modules at the machine.
A CC-Link master module is a special extension module, which assigns an FX3 or iQ-F PLC as the master station of a CC-Link system.
|Applicable for|Base units FX3G, FX3GC, FX3GE, FX3U, FX3UC,<br>FX5U,FX5UC<br>Base units FX5U, FX5UC|
|---|---|
|Module type|Master station<br>Master / Intelligent device station|
|Link points per station<br>I/Opoints<br>Register|32<br>32|
||8<br>8|
|Max. number of I/O points|FX3G/FX3GC/FX3GE: 32 x nbr. of stations<br>≤128 FX3U/FX3UC: 32 x nbr. of stations<br>≤2562<br>768|
|Number of connectable modules|Max. 16<br>Max. 24|
|Power supply<br>5 V DC<br>24 V DC|—<br>—|
||240 mA<br>100 mA|
|Related I/Opoints|8<br>8|
|Weight<br>kg|0.4<br>0.3|
|Dimensions(WxHxD)<br>mm|55x90x87<br>50x90x83|
- 1 To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
2 Total of I/O points in base unit and extension units within the CC-Link network ≤384.
Note : Please refer to manual for slave functionality.
## **FX3U-64CCL interface module**
The FX3U-64CCL CC-Link interface module is available for FX3G, FX3GC, FX3GE, FX3U or FX3UC series main units and enables CC-Link V2
functionality, for example expanded cyclic transmission which facilitates handling of multiple data processes.
|Module type|Intelligent device station|
|---|---|
|Link points per station<br>I/Opoints<br>Register|128(Occupying1 station with Octuple expanded cyclic setting)|
||32(Occupying1 station with Octuple expanded cyclic setting)|
|Max. transmission speed|10 Mbps|
|Related I/Opoints|8|
|Power supply<br>24 V DC|24 V DC/220 mA|
|Weight<br>kg|0.3|
|Dimensions(WxHxD)<br>mm|55x90x87|
Notes: When attaching the FX3U-64CCL to a FX3UC/FX3GC base unit, the FX2NC-CNV-IF interface converter or the FX3UC-1PS-5V power supply unit is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
62
Network modules
~~**4**~~
## ~~**Network module for CC-Link**~~ ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **CC-Link communication module**
**==> picture [40 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
LRUN • LERR • RD • SD<br>FX2N-32CCL<br>**----- End of picture text -----**<br>
The communication module FX2N-32CCL enables the user to connect to the CC-Link network with a superior PLC system as master CPU. This gives him access to the network of all MELSEC PLC systems and frequency inverters and to additional products from other suppliers.
Thus the network is expandable via the digital inputs/outputs of the FX modules to a maxi-
The buffer memory of the FX2N-32CCL is read and written by FROM/TO instructions.
The connection is to the extension bus on the right side of the controller.
mum of 256 I/Os.
|Module type<br>~~eC~~|Remote station<br>~~eC~~|
|---|---|
|Link points per station<br>I/Opoints <br>Register|32|
||8|
|Max. number of I/Opoints|—|
|Number of connectable modules|—|
|Power supply<br>5 V DC<br>24 V DC|Max. 130 mA(from base unit)|
||50 mA|
|Related I/Opoints|8|
|Weight<br>kg|0.3|
|Dimensions(WxHxD)<br>mm|43x90x87|
Notes: To connect this module to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
## ~~**Network module for CC-Link IE Field**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
CC-Link IE Field is a high speed (1Gbps), high capacity open field network using Ethernet (1000BASE-T).
FX5-CCLIEF is an intelligent function module to connect a FX5U or FX5UC* CPU module as an intelligent device station to a CC-Link IE Field network.
Data between the FX5 CPU module and the FX5-CCLIEF can be sent/received through the buffer memory using instructions in the program. The data can also automatically exchanged with the auto refresh function and used in a program.
* For the connection to a FX5UC CPU module a connector conversion module FX5-CNV-IFC or an extension power supply module FX5-C1PS-5V is required.
|**Specifications**||**FX5-CCLIEF**|
|---|---|---|
|Station type||Intelligent device station|
|Communication speed||1 Gbps|
||RX|384points,48 bytes|
|Max. number of|RY|384points,48 bytes|
|I/O points|RWr|1024points,2048 bytesa|
||RWw|1024points,2048 bytesa|
|Power supply|5 V DC<br>24 V DC|10 mA<br>230 mA(externalpower supply)|
|Related I/Opoints||8|
|Weight|kg|0.3|
|Dimensions(WxHxD)|mm|50x90x103|
||||
|**Order information**|Art. no.|297444|
- 1 256 points (512 bytes) when the master station is in high-speed mode.
63
Network modules
## ~~**Network module for Ethernet**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
~~**4**~~
**==> picture [80 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
‘EAN<br>=<br>FX3U-ENET<br>10BASE-T/100BASE-TX<br>RUN<br>INIT.<br>100M<br>SD<br>RD<br>ERR.<br>COM.ERR.<br>C1<br>C2<br>C3<br>C5<br>C6<br>C7<br>C8<br>POWER<br>C4<br>**----- End of picture text -----**<br>
## **Ethernet communications module**
addition to supporting full program UP/DOWN load as well as comprehensive monitoring support. The module also supports Peer to Peer connection and MC Protocol. It is easily set-up with the FX Configurator-EN software.
The FX3U-ENET communications module provides the FX3G, FX3GE, FX3U or FX3UC with a direct connection on to an Ethernet network.
With the FX3U-ENET installed an FX3G/FX3GE/ FX3U/FX3UC PLC can exchange data quickly and easily with process visualization systems in
|**Specifications**|**FX3U-ENET/FX3U-ENET-P502**|
|---|---|
|Protocol|TCP/IP,UDP|
|Communication mode|Full-duplex/half-duplex|
|No. of simultaneous open connections<br>Fixed buffer communication|8<br>1023 word x 8|
|Communication with mail server|SMTP,POP3|
|Interface<br>Connector<br>Max. transfer rate<br>Max. segment length<br>m <br>Cable<br>Power supply<br>5 V DC<br>24 V DC<br>Related I/Opoints<br>Weight<br>kg <br>Dimensions (WxHxD)<br>mm|IEEE802.3u(100BaseTX),IEEE802.3(10BaseT)<br>RJ45<br>100 Mbits/s,10 Mbit/s<br> 100<br>CAT5 STP or 3 STP<br>—<br>240 mA(from base unit)<br>8<br> 0.3<br> 55x90x87|
|||
|**Order information**<br>Art. no.|166086/225142|
Note: To connect this module to a FX3UC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Network module for Ethernet**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Ethernet communications adapter**
The FX3U-ENET-ADP communications adapter is an Ethernet interface with 10BASE-T specifications for the FX3G, FX3GC, FX3S or FX3U series.
The FX3U-ENET-ADP enables upload, download, monitor and test sequence of programs via Ethernet from a personal computer (GX Works2 or MX Components have to be installed).
|**Specifications**||**FX3U-ENET-ADP**|
|---|---|---|
|Protocol||TCP/IP|
|No. of simultaneous open connections||1|
|Interface||IEEE802.3u(100BaseTX),IEEE802.3(10BaseT)|
|Connector||RJ45(to Ethernet),3 screw terminals(toground)|
|Max. transfer rate||10 Mbit/s,100 Mbit/s|
|Cable||CAT5 STP or 3 STP|
|Power supply|5 V DC<br>24 V DC|30 mA(from base unit)<br>—|
|Related I/Opoints||0|
|Weight|kg|0.1|
|Dimensions (WxHxD)|mm|23x90(106)x81.5|
|**Order information**|Art. no.|248844|
Notes: This module can be connected directly (without adapter) to a base unit of the FX3GC or FX3UC series. To connect this module to a FX3G, FX3S or FX3U base unit, an adapter is required.
64
Network modules
~~**4**~~
## ~~**Network module for Profibus DP**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Profibus DP master modul**
**==> picture [41 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-64DP-M<br>RUN<br>TOKEN<br>FROM/TO<br>ERROR<br>POWER<br>**----- End of picture text -----**<br>
The FX3U-64DP-M Profibus DP master module enables you to integrate a MELSEC FX3U or FX3UC PLC system as a class 1 master of a Profibus DP network.
This interface module provides your FX3U/ FX3UC base unit with an intelligent Profibus DP link for the implementation of decentralised control tasks.
The FX3U Profibus DP master provides comprehensive data and alarm processing to the Profibus DP V1 standard. It is easily set up with the GX Configurator-DP software.
|Module type|Master station|
|---|---|
|Transmission type|Bus network|
|Transmission data|32 byte/slave (normal service mode)<br>244 byte/slave(extended service mode)|
|Interface|Profibus DP(with 9pole D-SUB connector)|
|Max. number of masterper configuration|max. 1|
|Repeaters|3|
|Max. number of slaves|64|
|Communications speed|Profibus standard|
|Communications distance<br>m|Max. 1200(depends on communication speed)|
|Communication cable|Profibus cable with 9-pin D-SUB connector|
|Power supply<br>5 V DC<br>24 V DC|—|
||Max. 155 mA(from base unit)|
|Related I/Opoints|8|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x87|
Notes: The FX3U-64DP-M can be used in combination with a FX3U or FX3UC base unit only. To connect this module to a FX3UC base unit, an adapter FX2NCCNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Network module for Profibus DP**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Profibus DP slave module**
The FX3U-32DP Profibus DP slave module is available for FX3G, FX3GC, FX3GE, FX3U and FX3UC series main units and allows the attached standard cyclic data exchange. FX main unit to function as a slave station on a Profibus DP-V1 network.
Profibus DP-V1 functionality supports extensive alarm processing and messaging on top of
**==> picture [417 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications FX3U-32DP<br>Module type Slave station<br>S a Transmission t Bus network<br>**----- End of picture text -----**<br>
|**Specificationspecificationsecifications**<br>**FX3U-32DP**<br>Module typeypee<br>Slave station<br>Transmission type<br>Bus network<br>~~a~~|
|---|
|Transmission data<br>Max. 144 bytes<br>Interface<br>9-pin D-SUB for Profibus DP|
|Max. number of slave stationsper configuration 8|
|Communication speed 5 V DC<br>Max. 12 Mbit/s|
|Communication<br>distance<br>24 V DC<br>Max. 1200 (depends on communication speed)|
|Communication cable<br>Profibus cable with 9-pin D-SUB connector|
|Related I/Opoints<br>8|
|Power supply<br>24 V DC/145 mA(from base unit)|
|Weight<br>kg 0.2|
|Dimensions (WxHxD)<br>mm 43x90x89|
|**Order information**<br>Art. no. 194214|
Note: To connect a FX3U-32DP to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
65
Network modules
~~**4**~~
## ~~**Remote I/O station for Profibus DP**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
**==> picture [97 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Gan ———<br>|<br>——<br>=<br>38 | a<br>FX2N-32DP-IF<br>ON<br>OFF<br>MITSUBISHI<br>RUN<br>STOP<br>COM 24 +<br>L N<br>POWER<br>RUN<br>BF<br>DIA<br>64 32 16 8 4 2 1<br>**----- End of picture text -----**<br>
The remote I/O station FX2N-32DP-IF-D forms an extremely compact communication unit and provides a connection of I/O modules with up to 256 I/O points and/or up to 8 special function modules as an alternative.
Profibus data such as the baud rate or I/O data can be monitored directly with the programming software or on the hand-held programming units FX-10P/FX-20P/FX-30P. This facilitates an easy error diagnosis directly on the remote I/O station.
It features an entire electrical isolation of the Profibus DP connector and of the sensor/actuator circuits.
|Power supply|24 V DC<br>(+20 %/-30 %)|
|---|---|
|Power consumption|14 W|
|Internal current consumption|5 V DC/max. 220 mA(from base unit)|
|Interface (connectors)|9-pin D-SUB for Profibus DP,<br>8-pin Mini-DIN for PC orprogrammingunit FX-10P/FX-20P/FX-30P|
|1200 m<br>kbps <br>1000 m<br>kbps <br>400 m<br>kbps <br>200 m<br>kbps <br>100 m<br>kbps|9.6/19.2/45.45/93.75|
||187.5|
||500|
||1500|
||3000/6000/12000|
|Communication distance<br>m|Max. 1200(depends on communication speed)|
|Communication cable|Profibus cable with 9-pin D-SUB connector|
|Max. number of controllable I/Opoints|256|
|Weight<br>kg|0.4|
|Dimensions (WxHxD)<br>mm|75x98x87|
## ~~**Network module for DeviceNet™**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **DeviceNet™ slave module**
The DeviceNet™ slave module FX2N-64DNET can be used to connect FX3G, FX3GC, FX3GE and FX3U programmable controllers to a DeviceNet™ network.
The FX2N-64DNET can communicate to the master by the master/slave communication (using the master/slave I/O connection), and to
other nodes supporting the UCMM connection by client/server communication (using the UCMM connection).
The communication between the programmable controller and the internal buffer memory of the FX2N-64DNET is handled by FROM/TO instructions.
|Module type|Slave(group2)|
|---|---|
|Node type|G2 server|
|Station numbers|0–63points|
|Supported communication speeds<br>kbps|125/250/500|
|Communication data<br>(open connection)<br>Master/<br>slave<br>no. of connections<br>transfer time-out<br>UCMM<br>client/server<br>no. of connections<br>data length|1 connection(group2)|
||2,000 ms(ACK time-out)|
||63/63(group1,3)|
||Max. 64 bytesper connection|
|Communication data<br>(I/O connection)<br>type<br>data length|Polling,cyclic,change of state|
||Max. 64 bytes(fragmentation ispossible)|
|Module ID code|K 7090|
|Status displays|Power,module status,network status|
|Related I/Opoints|8|
|Power supply<br>5 V DC<br>24 V DC|120 mA|
||50 mA|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x87|
66
Network modules
~~**4**~~
## ~~**Network module for CANopen**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
## **CANopen master module FX3U-CAN**
**==> picture [101 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
aN N CANoper® 0<br>EIS) ps<br>“ELE<br>RUN<br>FROM/TO<br>Tx/Rx<br>ERROR<br>POWER<br>AN_GND<br>AN_L<br>AN_SHLD<br>AN_H<br>AN_V+<br>FX3U-CAN<br>**----- End of picture text -----**<br>
Up to 320 process data objects (PDOs) can be sended or received. With the supported PLC device profile CiA 405 it can be connected with any other CANopen device profile like for example Drives device profile CiA 402, I/O module device profile CiA 401 or Encoder device profile CiA 406.
The FX3U-CAN communications module makes it possible to connect a FX3G, FX3GC, FX3GE, FX3U/FX3UC/FX5U or FX5UC PLC to an existing CANopen or CAN Layer-2 network.
In addition to real-time capabilities and highspeed data transfer at rates of up to 1 Mbit/s the CANopen module also shines with high transfer reliability and simple network configuration.
The CANopen® Lift application profile CiA 417 supports direct control of CANopen® lift devices
like Call devices, Drive devices or Lift doors.
|Module type<br>~~a~~|CANopen master<br>~~a~~|
|---|---|
|CANopen communication standard|CiA 301 V4.2,CiA 302 V4.1,CiA 305 V2.2|
|CANopen Lift applicationprofile mode|CiA 417 V2.1|
|CANopen PLC deviceprofile mode|CiA 405 V2.0|
|Max. number of modules that can be connected to the network|30 without repeater;127 with repeater|
|Station numbers|1–127|
|Supported communication speeds<br>kbps|10,20,50,125,250,500,800,1000|
|Status displays|RUN,Error,Power,Network status|
|Power supply<br>5 V DC<br>24 V DC|290 mA|
||—|
|Related I/Opoints|8|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x88.7|
Note: To connect this module to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Network module for J1939**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The FX3U-J1939 communication module allows the connection of FX3G/FX3U/FX3UC series PLCs to a J1939 network. J1939 is a CAN based protocol used for communication with motors, generators and compressors.
In a J1939 network are no master or slave stations. All nodes may receive each others’ messages. Standard messages contain up to 8 bytes of data, extended messages contain up to 250 bytes of data.
Up to 75 standard messages and 4 extension messages can be sent and received.
The FX3U-J1939 is compatible with CAN Layer 2 communication. In this mode, a FX3U-J1939 can send and receive up to 42 messages on a CAN network.
|**Specifications**|**FX3U-J1939**|
|---|---|
|Communication standard version|J1939|
|Network node size|J1939: 2–30|
|Communication method|Cyclic,acyclic or request driven(user configurable)|
|CAN layer-2 communication|Send and receive|
|Max. cable length<br>m|5000|
|Baud rates<br>kbit/s|10,20,50,100,125,250,500,800,1000|
|Power supply|24 V DC/110 mA(from base unit)|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x95|
|**Order information**<br>Art. no.|254276|
Note: To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
67
Communication modules
~~**4**~~
## ~~**AnyWireASLINK system master module**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
**==> picture [70 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
‘en<br>POWERRUN<br>ERROR<br>24V<br>0V<br>24V<br>0V<br>DP<br>DN<br>(LG)<br>AnyWire<br>SET<br>NI<br>OUT<br>**----- End of picture text -----**<br>
The FX5-ASL-M type AnyWireASLINK system master module is an intelligent function module for building an AnyWireASLINK sensor network.
|**Specifications**||**FX5-ASL-M**|
|---|---|---|
|Module type||AnyWireASLINK system master module|
|Max.number of I/Opoints<br>Number of connectable modules<br>Power supply<br>5 V DC<br>24 V DC<br>Related I/Opoints||384<br>128<br>200 mA<br>100 mA<br>8|
|Weight|kg|0.2|
|Dimensions (WxHxD)|mm|40x90x83 (97.3 with connector)|
||||
|**Order information**|Art. no.|312300|
## ~~**Modbus® & serial communication special adapter**~~
þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Active data module (RS485)**
The addition of an active data interface module permits active communication between the PLC and surrounding devices.
FX3U-485ADP-MB also supports Modbus® RTU and Modbus® ASCII.
With RS485 communication can be configured as either 1:N multidrop, parallel link or peer to peer operation.
|Interface|RS485;Modbus® RS485|
|---|---|
|Communication speed*<br>kbps|0.3–19.2|
|Max. communication distance<br>m|500|
|Power supply<br>5 V DC<br>24 V DC|20 mA(from base unit)|
||—|
|Related I/Opoints|0|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x74|
* The communication method and communication speed vary depending upon the communication type.
Notes: This adapter module can be connected directly (without special adapter) to a base unit of the FX3GC, FX3GE or FX3UC series. To connect this adapter module to a FX3G, FX3S or FX3U base unit, an adapter is required.
68
Communication modules
~~**4**~~
## ~~**RS485 communication expansion adapter**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
## **Isolation type communication adapter FX5-485ADP**
The expansion adapter FX5-485ADP expands a be increased to 1200 m in contrast to 50 m with FX5U or FX5UC base unit by an additional RS485 the built-in RS485 port or the FX5-485-BD. port. Between the communication line and the Up to two communication expansion adapters base unit photocoupler isolation is used. With can be mounted on the left side of a FX5U or the FX5-485ADP the transmission distance can FX5UC CPU base unit.
|Transmission standard<br>~~SS~~|Conformingto RS485 and RS422 standards<br>~~SS~~|
|---|---|
|Communication speed *<br>bps <br>~~SS~~|300/600/1200/2400/4800/9600/19200/38400/57600/115200<br>~~SS~~|
|Max. communication distance<br>m <br>~~SS~~|1200 m<br>~~SS~~|
|External device connection method<br>~~SS~~|Terminal block<br>~~SS~~|
|Power supply<br>5 V DC<br>24 V DC|20 mA(from base unit)|
||30 mA(from base unit)|
|Related I/Opoints|0|
|Weight<br>kg|0.08|
|Dimensions (WxHxD)<br>mm|17.6x106x74|
* The communication method and communication speed vary depending upon the communication type.
## ~~**Interface module**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Active data interface module FX3U-232ADP-MB**
The additional active data interface module permits active communication between the PLC and surrounding RS232C peripherals. All device information can be sent or received via these interfaces.
The connection is to the communications bus on the left side of the controller. The internal serial RS422 interface is also fully available.
The FX3U-232ADP-MB can also be used for communication via Modbus®.
The module is suitable for the connection of printers, bar code readers, PCs and other PLC systems. The communication is handled by the PLC program using the RS instruction.
|Interface<br>~~SS~~|RS232C with 9pole D-SUB connector(photocoupler isolation)<br>~~SS~~|
|---|---|
|Communication speed*<br>kbps|0.3–115.2|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)|
||—|
|Related I/Opoints|0|
|Weight<br>kg|0.08|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x81.5|
* The communication method and communication speed vary depending upon the communication type.
Notes: This module can be connected directly (without adapter) to a base unit of the FX3GC, FX3GE or FX3UC series. To connect this module to a FX3G, FX3S or FX3U base unit, an adapter is required.
69
Communication modules
~~**4**~~
## ~~**RS232C communication expansion adapter**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
## **Isolation type communication adapter FX5-232ADP**
Up to two communication expansion adapters can be mounted on the left side of a FX5U or
The expansion adapter FX5-232ADP adds a RS232C port to a FX5U or FX5UC base unit for communication between the PLC and peripheral FX5UC CPU base unit. devices. Between the communication line and the base unit photocoupler isolation is used.
|Transmission standard<br>~~eC~~|Conformingto RS232C standard<br>~~eC~~|
|---|---|
|Communication speed *<br>bps <br>~~eC~~|300/600/1200/2400/4800/9600/19200/38400/57600/115200<br>~~eC~~|
|Max. transmission distance<br>~~eC~~|15 m<br>~~eC~~|
|External device connection method|9pole D-SUB connector(male)|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)|
||30 mA(from base unit)|
|Related I/Opoints|0|
|Weight<br>kg|0.08|
|Dimensions (WxHxD)<br>mm|17.6x106x74|
* The communication method and communication speed vary depending upon the communication type.
## ~~**Interface module**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The interface module FX2N-232IF provides an RS232C interface for serial data communications with the MELSEC FX3U and FX3UC.
Communication with PCs, printers, modems, barcode readers etc. is handled by the PLC program.
The send and receive data are stored in the FX2N-232IF’s own buffer memory.
|Interface|RS232C with 9pole D-SUB connector(photocoupler isolation)|
|---|---|
|Communication speed<br>kbps|0.3–19.2|
|Communication distance<br>m|Max. 15|
|Communication cable|Shielded cable|
|Communication mode|Full duplex|
|Protocols|Nonprotocol mode/start stopsynchronisation|
|Send and receive buffer|512 byte each|
|Format|7 or 8 bits, paritynone/even/odd,stopbits: 1 or 2|
|Power supply<br>5 V DC<br>24 V DC|40 mA(from base unit)|
||80 mA|
|Related I/Opoints|8|
|Weight<br>kg|0.3|
|Dimensions (WxHxD)<br>mm|55x90x87|
Note: To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
70
Extension adapters
~~**4**~~
## ~~�~~ ~~**[Digital extension adapter boards ]**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
FX3G-4EX-BD
The extension adapters for the FX3G series are available with 4 inputs or 2 outputs.
These adapters are especially advantageous when only few additional I/Os are required and there is not enough room for an adjacent module to be installed.
They are installed directly in the controller of the FX3S or FX3G series and therefore do not require any additional installation space.
**==> picture [337 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications FX3G-4EX-BD FX3G-2EYT-BD<br>Integrated inputs/outputs 4 4<br>Power supply From base unit<br>Integrated inputs 4 —<br>Integrated outputs — 2<br>Voltage 24 V DC (+20 %/-15 %)<br>Input level<br>Current 5 mA (24 V DC)<br>Output type — Transistor<br>Max. switching voltage V — 5–30 V DC<br>Weight kg 0.02 0.02<br>Dimensions (WxHxD) mm 35x51.2x29.2 35x51.2x29.2<br>Order information Art. no. 271700 271701<br>**----- End of picture text -----**<br>
FX3G-2EYT-BD
## ~~�~~ ~~**[Analog adapter boards ]**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** þ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
FX3G-2AD-BD
FX3G-1DA-BD
The analog input adapter board FX3G-2AD-BD provides the user with 2 analog inputs. The board converts analog process signals into digital values which are further processed by the MELSEC FX3S/FX3G/FX3GE controller.
The analog adapter FX3G-1DA-BD provides the user with 1 analog output. This module converts digital values from the FX3S/FX3G/FX3GE controller to the analog signals required by the process.
**==> picture [337 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications FX3G-2AD-BD FX3G-1DA-BD<br>Power supply From base unit From base unit<br>Inputs 2 —<br>Analog channels Outputs — 1<br>Analog input range 0–+10 V DC/4–+20 mA 0–+10 V DC/4–+20 mA<br>Voltage input kΩ198.7 —<br>Input resistance Current input Ω250 —<br>Voltage output kΩ— 2–1,000<br>External load<br>Current output Ω— <500<br>Resolution 2.5 mV (12 bit)/8 µA (11 bit) 2.5 mV (12 bit)/8 µA (11 bit)<br>Fullscale overall accuracy ±1 % ±1 %<br>Analog → digital 180 µs (1 program cycle) —<br>Conversion speed Digital → analog — 60 µs (1 program cycle)<br>Related I/O points 0 0<br>Weight kg 0.02 0.02<br>Dimensions (WxHxD) mm 35x51.2x29.2 35x51.2x29.2<br>Order information Art. no. 221265 221266<br>**----- End of picture text -----**<br>
71
Extension adapters
~~**4**~~
## ~~**Analog setpoint adapter board**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** þ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
FX3G-8AV-BD FX3U-8AV-BD
Setpoint value polling and the definition of the potentiometer scales are performed in the PLC program using the dedicated instructions VRRD/ VRSC (FNC85/86).
The FX3G-8AV-BD and FX3U-8AV-BD analog setpoint adapter enables the user to set 8 analog setpoint values. The analog values of the potentiometers are read into the controller and used as default setpoint values for timers, counters and data registers by the user’s PLC programs.
The analog setpoint adapter is installed in the expansion slot of the CPU. No additional power supply is required for operation.
|Applicable for<br>~~ee~~|Base units FX3S/FX3G/FX3GE<br>Base units FX3U<br>~~ee~~|
|---|---|
|Power supply|From base unit<br>From base unit|
|Adjustingrange|8 Bit<br>8 Bit|
|Related I/Opoints|0<br>0|
|Potentiometer evaluation|Via application instruction from the PLC CPU(FNC 85/86)|
|Weight<br>kg|0.02<br>0.02|
|Dimensions (WxHxD)<br>mm|35x51.2x12<br>19.6x46.1x53.5|
## ~~**Communications adapter board**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
This adapter board allows direct USB 2.0 connection to the front of the FX3U PLC for program maintenance.
**Specifications FX3U-USB-BD** Applicable for Base units FX3U ~~ee~~ Power supply 5 V DC (from base unit) Weight kg 0.02 Dimensions (WxHxD) mm 19.6x46.1x53.5 **Order information** Art. no. 165284
## ~~**Expansion adapters**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The below listed expansion adapters enable the connection of the adapter modules FXmm-mmmADP on the left hand side of the
FX3S, FX3G and FX3U base units.
**Specifications FX3G-CNV-ADP FX3S-CNV-ADP FX3U-CNV-BD** Applicable for Base units FX3G Base units FX3S Base units FX3U Weight kg 0.1 0.1 0.01 Dimensions (WxHxD) mm 90x14.6x86 90x14.6x74 19.6x46.1x53.5 ~~ee~~ **Order information** Art. no. 221268 267132 165285
**==> picture [52 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-CNV-ADP<br>**----- End of picture text -----**<br>
72
Interface adapters
~~**4**~~
## ~~**Interface adapters**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** þ **FX3GE** þ **FX3U** ¨ **FX3UC** þ **FX5U** ¨ **FX5UC**
The FXmm-232-BD interface adapters provide an RS232C interface for serial data communications with the MELSEC FX3S, FX3G, FX3GE, FX3U or FX5U.
**==> picture [45 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-232-BD<br>**----- End of picture text -----**<br>
**==> picture [108 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-232-BD<br>FX5-232-BD<br>**----- End of picture text -----**<br>
|Applicable for|Base units FX3S/FX3G/FX3GE<br>Base units FX3U<br>Base units FX5U|
|---|---|
|Interface|RS232C with 9 pole D-SUB<br>connector<br>RS232C with 9 pole D-SUB<br>connector<br>RS232C with 9 pole D-SUB<br>connector|
|Power supply|5 V DC/20 mA(from base unit)<br>5 V DC/20 mA(from base unit)<br>5 V DC/20 mA(from base unit)|
|Related I/Opoints|—<br>—<br>—|
|Weight<br>kg|0.02<br>0.02<br>0.02|
|Dimensions (WxHxD)<br>mm|35x51.2x17.2<br>19.3x46.1x62.7<br>38x51.4x18.2|
The interface adapter FXmm-422-BD expand The interface adapter FX5-422-BD-GOT is used a MELSEC FX3S, FX3G, FX3GE or FX3U PLC to for the connection of a HMI to a FX5U CPU a second RS422 interface for connection of module. MITSUBISHI additional devices such as programming devices or HMIs. **Specifications FX3G-422-BD FX3U-422-BD FX5-422-BD-GOT** FX3G-422-BD Applicable for Base units FX3S/FX3G/FX3GE Base units FX3U Base units FX5U Interface RS422 with 8 pole mini DIN RS422 with 8 pole mini DIN RS422 with 8 pole mini DIN connector connector connector Power supply 5 V DC/20 mA (from base unit) 5 V DC/20 mA (from base unit) 5 V DC/20 mA (from base unit) FX5-422-BD-GOT Related I/O points — — — Weight kg 0.02 0.02 0.02 Ne ~~SC~~ Dimensions (WxHxD) mm 35x51.2x14.9 19.6x46.1x53.5 38x51.4x15.4 FX3U-422-BD **Order information** Art. no. 221252 165282 280515
The interface adapters FXmm-485-BD proconfiguration of RS485 1:n multidrop, parallel vide the controller with an additional RS485 link or peer-to-peer networks with FX3S, FX3G, interface. The adapter, which is simply inserted FX3GE, FX3U or FX5U systems. into the base unit’s expansion slot, enables the
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-485-BD<br>**----- End of picture text -----**<br>
|Applicable for<br>~~|~~|Base units FX3S/FX3G/FX3GE<br>Base units FX3U<br>Base units FX5U<br>~~|~~|
|---|---|
|Interface<br>~~|~~|RS485<br>RS485<br>RS485<br>RS485<br>~~|~~|
|Power supply<br>~~|~~|5 V DC/20 mA<br>(from base unit)<br>5 V DC/20 mA<br>(from base unit)<br>5 V DC/40 mA<br>(from base unit)<br>5 VDC/20 mA<br>(from base unit)<br>~~|~~|
|Related I/Opoints|—<br>—<br>—<br>—|
|Weight<br>kg|0.02<br>0.02<br>0.02<br>0.02|
|Dimensions (WxHxD)<br>mm|35x51.2x29.2<br>35x51,2x22<br>19.6x46.1x69<br>38x51.4x30.5|
**==> picture [45 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-485-BD<br>**----- End of picture text -----**<br>
FX3G-485-BD-RJ
73
Expansion adapter/Conversion modules
~~**5** |~~
## ~~**Expansion adapter**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The FX2NC-CNV-IF expansion adapter connects FX3UC main units with the standard FX0N/ FX2N/FX3U right side expansion bus.
~~a~~ **Specifications FX2NC-CNV-IF** Bus connection FX3UC bus to FX0N/FX2N/FX3U bus Weight kg 0.5 Dimensions (WxHxD) mm 14.6x90x74 **Order information** Art. no. 104508
## ~~**Connector conversion modules**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
The FX5-CNV-IF is used to connect extension connector type modules of the MELSEC FX5UC series to FX5U CPU module systems.
The FX5-CNV-IFC is used to connect I/O modules (extension cable type) or intelligent modules of the MELSEC FX5U series to FX5UC CPU module systems.
|Conversion type|FX5 (Extension cable type) -><br>FX5(Extension connector type)<br>FX5 (Extension connector type) -><br>FX5(Extension cable type)|
|---|---|
|Compatible CPU module|FX5U<br>FX5UC|
|No. of connectable modules|Max. 1<br>Max. 1|
|Power supply<br>5 V DC<br>24 V DC|—<br>—|
||—<br>—|
|Related I/Opoints|0<br>0|
|Weight<br>kg|0.06<br>0.06|
|Dimensions(WxHxD)<br>mm|14.6x90x74<br>14.6x90x74|
## ~~**Bus conversion modules**~~
¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
The FX5-CNV-BUS is a conversion module for The FX5-CNV-BUSC is a conversion module for connecting modules of the FX3 series to an connecting modules of the FX3 series to an extension cable type FX5 module. extension connector type FX5 module.
|Conversion type<br>~~ee~~|FX5(Extension cable type)-> FX3<br>FX5(Extension connector type)-> FX3<br>~~ee~~|
|---|---|
|Compatible CPU module|FX5U,FX5UCa<br>FX5Ub,FX5UC|
|No. of connectable modules|Max. 1<br>Max. 1|
|Power supply<br>5 V DC<br>24 V DC|150 mA(from base unit)<br>150 mA(from base unit)|
||—<br>—|
|Related I/Opoints|8<br>8|
|Weight<br>kg|0.1<br>0.1|
|Dimensions(WxHxD)<br>mm|16x90x83<br>14.6x90x74|
1 FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
2 FX5-CNV-IF is necessary to connect to FX5U.
74
Conversion adapter/Memory cassettes
~~**5**~~
## ~~|~~ ~~**Connector conversion adapter**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
FX5-CNV-BC
The FX5-CNV-BC is connected and used between the extended extension cable and the
The FX5-CNV-BC is an adapter to convert the The FX5-CNV-BC is connected and used connector of an extended extension cable (FX5-30EC or FX5-65EC) used between modules module of extension cable type. of extension cable type.
**Specifications FX5-CNV-BC** | ~~ee~~ Conversion type Extended extension cable -> FX5 module (Extension cable type) Compatible CPU module FX5U/FX5UC Weight kg 0.04 Dimensions (WxHxD) mm 60.5x40x16.4 **Order information** Art. no. 297456
## ~~**Memory media**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** þ **FX3GE** ¨ **FX3U** ¨ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
All FX3S, FX3G, FX3GC and FX3GE base units are equipped with a slot for the optional, robust memory cassette. By connection of this memory cassette, the internal memory of the controller is switched off and only the program specified in the respective memory cassette is run.
The memory cassette can upload/download programs to and from the FX PLC internal memory with the help of 2 buttons.
The memory cassette FX3G EEPROM 32L can also be mounted on an already installed BD interface or expansion adapter.
FX3G-EEPROM-32L
|**Specifications**|**FX3G-EEPROM-32L**|
|---|---|
|Memorytype|EEPROM|
|Size|32,000 steps(4,000 steps for FX3S)|
|Protect switch|Provided|
|Data transfer buttons|Provided|
|**Order information**<br>Art. no.|221269|
## ~~**Memory media**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The FX3U-FLROM-64L features additional data
The memory cassette can be installed at the main unit, and when installed, the memory transfer buttons. cassette’s internal program is used in place of the internal RAM memory.
**Specifications FX3U-FLROM-16 FX3U-FLROM-64 FX3U-FLROM-64L** ~~ee~~
|Applicable for<br>~~ee~~|Base units FX3U/FX3UC<br>Base units FX3U/FX3UC<br>Base units FX3U/FX3UC<br>~~ee~~|
|---|---|
|Size|16,000 steps<br>64,000 steps<br>64,000 steps|
|Memorytype|Flash memory<br>Flash memory<br>Flash memory|
|Protect switch|Provided<br>Provided<br>Provided|
|Data transfer buttons|—<br>—<br>Provided|
|Dimensions (WxHxD)<br>mm|37x20x6.1<br>37x20x6.1<br>37x20x6.1|
75
External terminal blocks
~~**5** a~~
## ~~**Terminal blocks**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** þ **FX5UC**
**==> picture [86 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB-20C<br>— =<br>TB-lEXl<br>2 4 6 8 10 12 14 16 18 20<br>.0 .1 .2 .3 .4 .5 .6 .7<br>**----- End of picture text -----**<br>
**==> picture [42 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply<br>terminal<br>**----- End of picture text -----**<br>
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
System adapter<br>**----- End of picture text -----**<br>
**==> picture [119 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sockel<br>Base<br>ANN saaaeene<br>terminal<br>TB-lEYl<br>A2- A2- A2- A2- A2- A2- A2- A2-<br>24V 24V 24V 24V 24V 24V 24V 24V<br>.0 .1 24V+.2 .3 -PLC-V8/FLK14/OUT.4Art. 22 95 55 4.5 .6 .7<br>**----- End of picture text -----**<br>
Base device structure
**==> picture [151 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catch SS Terminal operation<br>aperture<br>LED status<br>NS |Z display<br>eS,9 aA<br>A)<br>Inserted<br>relay or<br>transistor<br>\3 |Nama element<br>Y IN Na<br>Contact for<br>plug-in strip Notch lever for<br>bridge securing and<br>ejecting<br>**----- End of picture text -----**<br>
The TB-8EY-S output block consists of 8 standard terminals and a system adapter. The standard terminals can be populated with relay or transistor elements, which makes it possible to configure the system for much higher output currents.
These terminal blocks are adapter modules that simplify the wiring of the inputs and outputs of the FX3UC main units with ribbon cable connectors. This practical, time-saving wiring system also improves the performance of the outputs. Special terminal blocks are also available for the FX3U/FX3UC positioning modules with ribbon cable connectors.
Preconfigured system cabling is available for all the terminal blocks (see next page).
Input blocks, output blocks and combined I/O blocks are available, with a choice of different terminal types.
The TB-mEXm input blocks are fitted with rows of bridged connectors for 24 V/0 V terminals,
which make wiring quick and easy.
|**Specifications**<br>**TB-8EX-C**<br>**TB-16EX-S**<br>**TB-16EX-C**<br>Type<br>Input block<br>Input block<br>Input block<br>Integrated inputs<br>8<br>16<br>16<br>Design<br>Initiator module withpotential terminals<br>~~ee~~|**Specifications**<br>**TB-8EX-C**<br>**TB-16EX-S**<br>**TB-16EX-C**<br>Type<br>Input block<br>Input block<br>Input block<br>Integrated inputs<br>8<br>16<br>16<br>Design<br>Initiator module withpotential terminals<br>~~ee~~|
|---|---|
|Connection type|Springterminals<br>Screw terminals<br>Springterminals|
|Dimensions (WxHxD)<br>mm|75x45x63<br>116x45x54<br>116x45x63|
|||
|**Order information**<br>Art. no.|149145<br>149021<br>149022|
|||
|**Accessories**|Connection cable(see following page)|
|**Specifications**|**TB-8EY-S**<br>**TB-20-S**<br>**TB-20C**|
|Type|Output block<br>Input/output block<br>Input/output block|
|Channels|8<br>8/16<br>8/16|
|Design|Socket for relayor transistor elements<br>20pin terminal module|
|Connection type|Screw terminals<br>Screw terminals<br>Springterminals|
|Dimensions (WxHxD)<br>mm|49.6x100x94<br>75x45x52<br>75x45x52|
|||
|**Order information**<br>Art. no.|149044<br>149148<br>149023|
|||
|**Accessories**|Pluggable function elements (see below),<br>Connection cable(see following page)<br>Connection cable (see following page)|
The transistor and relay elements are plugged Neighbouring terminals with identical voltages directly into the standard terminals in the can be connected with plug-in strip bridge conTB-8EY-S or TB-8EY-C modules. All the elements nectors, which can be cut to length as required. feature a status LED, protection against reverse polarity connection and a freewheeling diode.
|**Specifications**<br>Output type|**TB-8RELAY-6A**<br>**TB-8TRANSISTOR-2A**<br>Relaywith 1 switch-over contact<br>Transistor(with optocoupler)<br>~~ee~~|
|---|---|
|Number of elements|8<br>8|
|Rated input voltage|24 V DC<br>24 V DC|
|Switchingvoltage(min./max.)|12 V AC/DC;250 V AC/DC<br>3 V DC;33 V DC|
|Limitpermanent current|6 A<br>3 A(at 20 °C),2 A(at 60 °C)|
|Max. breakingcapacity|140 W(24 V DC),1500 VA(250 V AC)<br>—|
|Ambient temperature|-20–+60 °C<br>-20–+60 °C|
|||
|**Order information**<br>Art. no.|149034 (set with 8 elements)<br>149035 (set with 8 elements)|
|||
|**Accessories**|Insulated infinite pin bridge for potential isolation, TB-PIB-RD, color red, art.-no.: 149146;<br>Insulated infinite pin bridge for potential isolation, TB-PIB-BL, color blue art.-no.: 149147;<br>Isolationplate TB-SP for lateral base terminal connection,art.-no.: 149158|
76
Cable and connection terminals
~~**5**~~
## ~~**Terminal connection cable**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** þ **FX5UC**
These preconfigured cables enable quick, The cables are available in a choice of lengths error-free wiring of the terminal blocks of the between 1 and 5 m. Other lengths are also positioning modules for the FX3U and FX3UC possible by special order. series fitted with ribbon cable connectors.
|**Specifications**<br>**TB-EX-CAB-1M**<br>**TB-EX-CAB-3M**<br>**TB-EX-CAB-5M**|
|---|
|Application<br>For TB-lEXland TB-20-l (1:1 cable)|
|Length<br>m 1<br>3<br>5|
|**Order information**<br>Art. no. 149038<br>149039<br>149040|
|**Specifications**<br>**TB-EY-CAB-1M**<br>~~ee~~|
|Application<br>For 2 x terminal block TB-8EY-S or TB-8EY-C(Y cable)|
|Length<br>m 1|
|**Order information**<br>Art. no. 149041|
## ~~**Connection terminals**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The base unit FX2NC-16MR-T-DS and the extension units FX2NC -16EX-T-DS and FX2NC-16EYRT-DS are fitted with screw terminals as standard equipment.
These plug-in terminals can easily be replaced with spring terminals if required.
Two replacement terminal units are required for each module with 16 I/Os.
|**Specifications**<br>Number of terminalpoints<br>Connection type<br>Dimensions (WxHxD)<br>mm <br>**Order information**<br>Art. no.|**TB-CON-5-C**<br>**TB-CON10-C**<br>5<br>10<br>Springterminals<br>Springterminals<br> 12.5x20x21<br>12.5x20x21<br> 221539<br>149036|
|---|---|
77
Power supplies
~~**5**~~
## ~~**24 V power supply unit**~~
## þ **ALPHA** þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The ALPHA-POWER units are a convenient power supply for 24 V units and other external devices. They come with mounting system for wall or DIN rail mounting and their dimensions are matched to those of the ALPHA family.
Up to 5 power supply units can be installed together for redundant mode operation or connected in parallel for more power. The units have an integrated thermal overload protection circuit and a POWER LED. The output voltage is adjustable.
|Application|Power supplyfor 24 V DC Alpha base units|
|---|---|
|General specifications|Conforms to FX familyand ALPHA base units|
|Nominal input voltage|100–240 V(45–65 Hz)|
|Output voltage|24 V DC(+/-1 %)|
|Nominal output current|0.75 A(at T=55 °C)<br>1.75 A(at T=55 °C)<br>2.5 A(at T=55 °C)|
|Max. output current|1.4 A<br>3.75 A<br>4.4 A|
|Ambient temperature|-25–+55 °C(operation),-40–+85 °C(storage)|
|Ambient humidity|Max. 95 %(no condensation)|
|Weight<br>kg|0.1<br>0.2<br>0.3|
|Dimensions (WxHxD)<br>mm|36x90x61<br>54x90x61<br>72x90x61|
## ~~**5 V power supply unit**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The power supply modules FX3U-1PSU-5V and FX3UC-1PS-5V are used to reinforce the built-in 5 V DC and 24 V DC power supply of a FX3G/ FX3GC/FX3GE/FX3U/FX3UC main unit.
Up to two FX3U-1PSU-5V or FX3UC-1PS-5V modules can be used.
Both modules have an integrated overload protection available.
They do not occupy any I/O points and deliver up to 1 A more current for the 5 V system bus (for special function modules).
**==> picture [31 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX -1PSU-5V3U<br>**----- End of picture text -----**<br>
|Application|Power supply for the FX3G/FX3GE/FX3U/FX5U<br>system bus<br>Power supply for the FX3GC/FX3UC system bus|
|---|---|
|General specifications|Conforms to FX familybase units|
|Nominal input voltage|100–240 V(50/60 Hz)<br>24 V DC(+20 %/-15 %)|
|Output voltage|5 V DC/24 V DC<br>5 V DC|
|Max. output current<br>5 V DC <br>24 V DC|1 A at 40 °C;0.8 A at 55 °C<br>1 A|
||0.3 A at 40 °C;0.2 A at 55 °C<br>—|
|Ambient temperature|-25–+55 °C(operation),-40–+85 °C(storage)|
|Ambient humidity|Max. 95 %(no condensation)|
|Weight<br>kg|0.3<br>0.15|
|Dimensions (WxHxD)<br>mm|55x90x87<br>24x90x74|
Notes: The FX3U-1PSU-5V can't be used with a 24 V base unit!
When connecting an input extension module (incl. FX2N-8ER-ES/UL, FX2N-8ER) to the FX3U-1PSU-5V, supply the power for it from the 24 V DC service power supply of the connected main unit or powered extension unit on the upstream side.
78
Power supplies/Batteries
~~**5**~~
## ~~**Extension power supply modules**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
The power supply module FX5-1PSU-5V is used when the FX5U (AC power supply type) CPU module’s internal power supply is insufficient. Up to two FX5-1PSU-5V units can be used for one system.
The power supply module FX5-C1PS-5V is required when the built-in power supply is
insufficient in the FX5U (DC power type) and FX5UC CPU modules. When connecting a module of extension cable type to a FX5UC CPU module, the FX5-C1PS-5V also acts as a connector conversion module. Up to two FX5-C1PS-5V units can be used for one system.
|Application|Power supply for FX5U (AC power supply type) Power supply for FX5U (DC power supply<br>type)and FX5UC|
|---|---|
|Ratedpower supplyvoltage|100–240 V AC(50/60 Hz)<br>24 V DC|
|Power consumption|Max. 20 W<br>Max. 30 W|
|Output voltage|5 V DC/24 V DC<br>5 V DC/24 V DC|
|Max. output current<br>5 V DC <br>24 V DC|1.2 A at 40 °C;0.8 A at 55 °C<br>1.2 A at 40 °C;0.8 A at 55 °C|
||0.3 A at 40 °C;0.2 A at 55 °C<br>0.625 A at 40 °C;0.4 A at 55 °C|
|No.of connectable modules|Max. 2<br>Max. 2|
|Related I/Opoints|0<br>0|
|Weight<br>kg|0.3<br>0.1|
|Dimensions (WxHxD)<br>mm|50x90x83<br>20.1x90x74|
## ~~**SD memory card**~~
## ¨ **FX3S** ¨ **FX3G** ¨ **FX3GC** ¨ **FX3GE** ¨ **FX3U** ¨ **FX3UC** þ **FX5U** þ **FX5UC**
The built-in SD memory card slot can be used for data logging and convenient program update.
**==> picture [20 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
8GB<br>**----- End of picture text -----**<br>
|**Specifications**<br>**SDHC CARD 8GB**|
|---|
|Memory<br>type SDHC|
|Memory capacity<br>8 GB|
|**Order information**<br>Art. no. 306787|
## ~~**Backup batteries**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
## **Batteries**
The battery buffers the internal RAM of the The battery FX3U-32BL can be used for all base MELSEC PLC in the event of a voltage failure. units of the MELSEC FX3G/FX3GC/FX3GE/FX3U/ FX3UC/FX5U/FX5UC series. iG> ~~ee~~ **Specifications FX2NC-32BL FX3U-32BL** Base units FX3G/FX3GC/FX3GE/FX3U/FX3UC/ Applicable for FX2N-20GM module FX5U/FX5UC FX3U-32BL
|**Specificationspecificationsecifications**<br>**FX2NC-32BL**<br>~~ee~~|**FX3U-32BL**<br>~~ee~~|
|---|---|
|Applicable for<br>FX2N-20GM module<br>~~ee~~|Base units FX3G/FX3GC/FX3GE/FX3U/FX3UC/<br>FX5U/FX5UC<br>~~ee~~|
|**Order information**<br>Art. no. 128725|165286|
79
Cables
**#2** ~~**5** ;~~
## ~~**Cables**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **FX series connection cables**
The cable listed in the following tables are used applications, block connections and interface for FX series PLC programming, positioning conversion.
## **Connection cable for peripherals**
|**Specifications**|**F2-232CAB-1**<br>**FX-422CAB0**<br>**FX-422CAB**|
|---|---|
|Applicable for|PC to FX-232AWC-H|
|Peripheral type|RS232C<br>RS422<br>RS422|
|Length<br>m|3.0<br>1.5<br>0.3|
|||
|**Order information**<br>Art. no.|76163<br>76094<br>25949|
FX5-65EC
**Connection cable for programming unit Specifications FX-20P-CADP** Application FX-20P-CAB to FXm PLC Length m 0.3 ~ ~ ~~a~~ **Order information** Art. no. 31870 y F2-232CAB-1 **Connection cable for extension bus** ~~a~~ **Specifications FX0N-65EC FX2N-CNV-BC** PLC bus cable for two-stage-configuration with Adapter for the connection of the FX0N-65EC to Application extension units FXmm-mmES special function modules FX3U/FX2N Length m 0.65 **Order information** Art. no. 45348 70880 **Extended extension cables** ~~a~~ **Specificationspecificationsecifications FX5-30EC FX5-65EC** FX-20P-CADP Connect ion of an extension module located distantly or on a second stage. Depending on the module to
~~a~~ **Specificationspecificationsecifications FX5-30EC FX5-65EC** Connect ion of an extension module located distantly or on a second stage. Depending on the module to Application be connected with, a connection conversion adapter FX5-CNV-BC is required. Length m 0.3 0.65 **Order information** Art. no. 297457 297458
**Interface converter**
~~ee~~ **Specifications FX-USB-AW FX-232AWC-H** Application USB to RS422 converter RS422 to RS232C converter Dimensions (WxHxD) mm 62x21x15 80x60x25 **Order information** Art. no. 165288 159642
## ~~**Programming cables**~~
## ¨ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
The USB to RS422 converter FX-USB-AW is used The converter is devided into 2 parts and thus for the connection between the PLC and a serial universally applicable for all FX-series PLCs. interface of a personal computer. **FX-USB-AW** gy5 ~~a~~ Connection on PC side USB **Order information** Art. no. 165288 FX-USB-AW
80
Displays
~~**5**~~
## ~~**Display modules**~~
## þ **FX3S** þ **FX3G** ¨ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
## **Display modules FX3G-5DM/FX3S-5DM**
The display modules FX3G-5DM and FX3S-5DM A display module e.g. can be used instead of are inserted directly with space-saving into the digital switches and external 7-segment displays controller and enable monitoring and editing of in very confined areas. the data stored in the PLC.
**==> picture [38 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-5DM<br>**----- End of picture text -----**<br>
|Applicable for<br>~~eer~~|Base units FX3S<br>Base units FX3G/FX3GE<br>~~eer~~|
|---|---|
|Display|LCD(with backlight)<br>LCD(with backlight)|
|Power supply|5 V DC ±5 %(from base unit)<br>5 V DC ±5 %(from base unit)|
|Current consumption<br>mA|n/a<br>n/a|
|Dimensions (WxHxD)<br>mm|35x51.2x12<br>49x34x12|
FX3S-5DM
## **Control and display panel FX-10DM-E**
The control and display panel FX-10-DM-E provides a key-oriented user-interface and enables you to monitor and edit process data in the PLC. The display is arranged in 2 rows of 16 characters each. Functions can be invoked and values can be edited using the panel keys.
The connection with the PLC is possible via the cable FX-20P CAB0.
|**Specifications**<br>**FX-10DM-E**|
|---|
|Applicable for<br>All base units FX3U|
|Display<br>LCD(with backlight)|
|Resolution<br>2x16 signs(80x16pixles)|
|Power supply<br>5 V DC ±5 %(from base unit)|
|Current consumption<br>mA 220|
|Weight<br>kg 0.02|
|Dimensions (WxHxD)<br>mm 96x62x32|
||
|**Order information**<br>Art. no. 132600|
## **Control and display panel FX3U-7DM and holder FX3U-7DM-HLD**
The FX3U-7DM display module can be incorthe enclosure using the FX3U-7DM-HLD display porated in the main unit, or can be installed in module holder.
|Applicable for<br>~~a~~|Base units FX3U<br>Base units FX3U<br>~~a~~|
|---|---|
|Display<br> ~~a~~|16 letters x 4 lines<br>—<br>~~a~~|
|Resolution|—<br>—|
|Power supply|5 V DC(from base unit)<br>—|
|Current consumption<br>mA|20<br>—|
|Extension cable|—<br>Included|
|Weight<br>kg|0.02<br>0.01|
|Dimensions (WxHxD)<br>mm|48x35x11.5<br>66.3x41.8x13|
Panel FX3U-7DM with built-in holder FX3U-7DM-HLD
Please refer to the HMI family catalogue for further operator terminals
81
ALPHA system outline
~~**6**~~
## ~~**The ALPHA 2 series**~~
**==> picture [510 x 660] intentionally omitted <==**
**----- Start of picture text -----**<br>
The analog inputs (0–10 V, 9 bits resolution)<br>Up to 15 inputs can be used as digital can be used very easily due to the integrated<br>inputs and up to 8 for analog inputs gain function and a Schmitt-trigger.<br>(controllers with 24 V DC supply). The communication with a com-<br>puter and with external peripherals<br>is supported by the two integrated<br>serial interfaces.<br>Integrated calender/real-time function (_eN<br>with up to 1200 switch ON or OFF<br>commands in one program == SEN<br>Direct programming via 8 function<br>keys on the front control panel<br>[rl without any additional program-<br>e! ee e e | ming device<br>oq<br>*<br>The units can be expanded<br>© to additional inputs/outputs<br>with extension modules to<br>be mounted directly into the<br>controller<br>Flexible mounting through integrated<br>DIN rail adapter and screw fixing<br>Large LC display for programming, The program is stored in a maintenance-free<br>entering, and editing plain text, EEPROM with a memory capacity of 5000 bytes.<br>values and bar graphs A backup battery is not required.<br>Password protection<br>can be activated.<br>Description of the unit components<br>Power supply terminals<br>Mounting hole Terminals for<br>digital/analog inputs<br>Ni ircobasssonsecooclp<br>_——— [et] Connector for PC, GSM,<br>Adapter for DIN rail mounting modem and other<br>automation components<br>J SSaarq ll _ l e l<br>Slot for EEPROM cassette<br>or connector for im ee Operating keys (8 pcs.)<br>programming cable =|} /L@L@_O \ J Housing cover (place holder) for<br>the extension modules<br>Protective cover [ SaNL i gss |- SS SS<br>LC Display RI<br>(4 lines x 12 characters)<br>Connection for extensions<br>Terminals for digital outputs<br>ESC<br>OK<br>DC INPUT<br>AL2-24MR-D<br>POWER<br>24V DC<br>POWER<br>24V DC<br>ESC<br>OK<br>+ -<br>+ -<br>(A) (B) 1 2 3 4 5 6 7 DC INPUT8 9 10 11 12 13 14 15<br>AL2-24MR-D<br>(A) (B) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br>MITSUBISHI<br>MITSUBISHI<br>**----- End of picture text -----**<br>
82
ALPHA base units
~~**6**~~
## ~~**Specifications ALPHA 2**~~
## **ALPHA 2 base units**
**==> picture [153 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
ee<br>© Z<br>» [@] [©] [©] [©O] a<br>Ss<br>e.g. AL2-24Mm-m<br>+ -<br>(A) (B) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br>ESC<br>OK<br>AL2-24MR-D<br>POWER24V DC<br>DC INPUT<br>MITSUBISHI<br>**----- End of picture text -----**<br>
The ALPHA 2 controllers offer simple reliable control for a range of automation applications including lighting, air conditioning, security systems, and temperature and water control.
- z Transistor and relay output options
- z Analog input/output
- z High speed counters up to 1 kHz
- z GSM function for communication with mobile phones
- z Language support for 8 different languages
- z Display unit for messages and function block data
## **Base units with 10–24 I/Os**
|**Specifications**<br>**AL2-10MR-A**<br>**AL2-10MR-D**<br>**AL2-14MR-A**<br>**AL2-14MR-D**<br>**AL2-24MR-A**<br>**AL2-24MR-D**<br>~~ee~~|
|---|
|**Electrical specifications**|
|Integrated inputs/outputs<br>10<br>10<br>14<br>14<br>24<br>24<br>Power supply<br>100–240 V AC<br>24 V DC<br>100–240 V AC<br>24 V DC<br>100–240 V AC<br>24 V DC|
|Digital inputs<br>6<br>6<br>8<br>8<br>15<br>15|
|Analog inputs<br>—<br>6<br>—<br>8<br>—<br>8<br>Channels<br>—<br>6<br>—<br>8<br>—<br>8<br>Integrated outputs<br>4<br>4<br>6<br>6<br>9<br>9<br>Max.power consumption<br>W 4.9<br>4.0<br>5.5<br>7.5<br>7.0<br>9.0|
|Typ. power<br>consumption<br>All I/Os<br>ON/OFF<br>W 3.5/1.85 240 V AC<br>3.0/1.55 120 V AC<br>2.5/0.75<br>4.5/2.0 240 V AC<br>3.5/1.5 120 V AC<br>4.0/1.0<br>5.5/2.5 240 V AC<br>4.5/2.0 120 V AC<br>5.0/1.0|
|Weight<br>kg 0.2<br>0.2<br>0.3<br>0.3<br>0.35<br>0.3|
|Dimensions(WxHxD)<br>mm 71.2x90x55<br>71.2x90x55<br>124.6x90x52<br>124.6x90x52<br>124.6x90x52<br>124.6x90x52|
||
|**Order information**<br>Art. no. 215070<br>215071<br>215072<br>215073<br>215074<br>215075|
||
|**Accessories**<br>Power supplies with DIN-rail or wall mounting possibilityforpoweringthe 24 V DC modules(refer to thepower supplychapter in this catalogue);|
83
General specifications
~~**6**~~
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Alpha 2 series<br>Ambient temperature Display: -10–55 °C, Hardware: -25–55 °C (storage temperature: -30–+70 °C)<br>Protection rating IP20<br>Noise immunity 1000 Vpp with noise generator; 1 µs at 30–100 Hz, tested by noise simulator<br>Dielectric withstand voltage 3750 V AC, >1 min. according to EN 60730<br>Allowable relative humidity 35–85 % (no condensation)<br>Shock resistance Acc. to IEC 68-2-27: 147 m/s [2] acceleration, 11 ms 3x3 directions<br>Direct mounting Acc. to IEC-2-6: 19.6 m/s [2] acceleration, 80 min. in each direction<br>Vibration resistance<br>DIN rail mounting Acc. to IEC-2-6: 9.8 m/s [2] acceleration, 80 min. in each direction<br>Insulation resistance 500 V DC, 7 MΩ acc. to EN60730-1<br>Ambient conditions No corrosive gases, no dust<br>Certifications Please refer to pages 103–105<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 262] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC powered modules AC powered modules<br>Power supply specifications (AL2- m MR-D) (AL2- m MR-A)<br>Power supply 24 V DC 100–240 V AC (50/60 Hz)<br>Inrush current at ON ≤ 7.0 A (at 24 V DC) ≤ 6.5 A (at 240 V AC)<br>Allowable momentary power failure time 5 ms 10 ms<br>Digital Inputs<br>24 V DC 100–240 V AC<br>Input voltage (+20 %/-15 %) (+10 %/-15 %), 50/60 Hz<br>The input current changes<br>depending on Source or Sink.<br>For Sink: I01–I08<br>(AL2-10/14/24MR-D) 0.13 mA/120 V AC*<br>= 5.5 mA, 24 V DC 0.25 mA/240 V AC*<br>Input current For Source: I09–I15<br>(AL2-10/14MR-D) 0.15 mA/120 V AC*<br>= 6.0 mA, 24 V DC 0.29 mA/240 V AC*<br>(AL2-24MR-D)<br>= 5.5 mA, 24 V DC<br>Response time OFF → ON ms 10–20 35–85 ms, 120 V AC 25–55 ms, 240 V AC<br>ON → OFF ms 10–20 35–85 ms, 120 V AC 50–130 ms, 240 V AC<br>Analog inputs<br>Digital input range 0–500 —<br>Resolution 9 bit, (10 V/500) —<br>Conversion speed ms 8 —<br>Voltage 0–10 V DC —<br>Impedance kΩ142 ±5 % —<br>Accuracy ±5 % (0.5 V DC) —<br>**----- End of picture text -----**<br>
**==> picture [250 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output specifications All modules<br>Type Relay<br>Switching voltage (max.) V 250 V AC, 30 V DC<br>10M, 14M: 8 A/point<br>Rated current 24M (001-004): 8 A/point<br>24M (005-009): 2 A/point<br>Max. switching load - inductive load 14M, 24M: 249 VA, 250 V AC/373 VA, 250 V AC 24M: 93 VA, 125 V AC/93 VA, 250 V AC<br>Minimum load 10 mA, 5 V DC<br>Response time ms ≤ 10<br>**----- End of picture text -----**<br>
* Current leakage from the sensors connected to the inputs might provide enough current to turn the controller ON. Do not use two wire sensors.
84
Extension modules
~~**6**~~
**==> picture [78 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
(hEM [SEE] Y=n [N] el<br>N<br>i z,<br>RR<br>EO3 EO4<br>OUTPUTRELAY<br>4EYR<br>MITSUBISHI<br>EO1 EO2<br>**----- End of picture text -----**<br>
## **Digital extension modules**
There are 4 different extension modules available for the ALPHA 2, which allow the controller to be extended through additional inputs or outputs. The modules are inserted directly into the ALPHA 2 and therefore do not take up any additional space.
The AL2-4EX has the additional feature that 2 inputs may be used as high-speed counters with a counting frequency of 1 kHz.
All modules feature photocoupler insulation for all I/Os.
~~ee~~ **Digital extension modules specifications AL2-4EX-A2 AL2-4EX AL2-4EYR AL2-4EYT**
|**Inputs**|**Inputs**|
|---|---|
|Integrated inputs|4<br>4<br>—<br>—|
|Input voltage|220–240 V AC<br>24 V DC(+20 %,-15 %)<br>—<br>—|
|Input current|7.5 mA at 240 V AC (50 Hz),<br>9.0 mA at 240 V AC(60 Hz)<br>5.4 mA ±1 mA at 24 V DC<br>—<br>—|
|**Outputs**||
|Integrated outputs|—<br>—<br>4<br>4|
|Output type|—<br>—<br>Relay<br>Transistor|
|Switched voltage(max.)<br>V|—<br>—<br>250 V AC,30 V DC<br>5–24 V DC|
|Rated current<br>A|—<br>—<br>2 Aper output<br>1 Aper output|
|**Electrical specifications**||
|Power supply<br>AC range<br>(+10 %,-15 %)|220–240 V AC<br>24 V DC<br>100–240 V AC<br>24 V DC|
|**Mechanical specifications**||
|Weight<br>kg|0.05<br>0.05<br>0.05<br>0.05|
|Dimensions (WxHxD)<br>mm|53.1x90x24.5<br>53.1x90x24.5<br>53.1x90x24.5<br>53.1x90x24.5|
Note: I1 and I2 of the AL2-4EX can be used as high-speed counter inputs. In each case the response time for the high-speed counter inputs will be 0.5 ms or less. The AL2-4EX-A2, AL2-4EX, AL2-4EYR and AL2-4EYT modules can not be used with the AL2-10MR series.
## **Analog extension modules**
**==> picture [137 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
V2+ I2+ VI2-<br>+ -<br>+ -<br>AL2-2PT-ADPPT100 -50~200°C<br>K-type Thermocouple -50~450°CAL2-2TC-ADP<br>POWER24V DC ANALOGOUTPUT<br>ANALOGOUTPUT 2DA<br>MITSUBISHI<br>MITSUBISHI<br>POWER<br>POWER<br>V1+ V1- V2+ V2-<br>POWER24V DC OUTPUT 0~10V<br>V1+ V1- V2+ V2-<br>POWER24V DC OUTPUT 0~10V<br>200°C -50°CCH1 Line 200°C CH2-50°C Line<br>450°C -50°CCH1 Line 450°C CH2-50°C Line CH1 CH2<br>L1+ L1- I1- L2+ L2- I2-<br>CH1 CH2<br>L1+ L1- SLD L2+ L2- SLD<br>CH1 CH2<br>CH1 CH2<br>MITSUBISHI<br>+ - V1+ I1+ VI1-<br>**----- End of picture text -----**<br>
The analog extension modules significantly increase the range of applications for the ALPHA 2. With these modules it is possible to output voltage or current signals or to measure temperatures.
Three different analog extension modules are available:
The AL2-2DA offers two additional analog outputs for the ALPHA 2 and converts a digital input value into a voltage or a current. This module is inserted directly into the ALPHA 2.
The AL2-2PT-ADP connects an external PT100 sensor to convert temperature readings into analog signals (0–10 V).
The AL2-2TC-ADP connects thermocouple sensors (K type) to convert temperature readings
into analog signals (0–10 V).
~~sii~~ **Analog extension modules specifications AL2-2DA AL2-2PT-ADP AL2-2TC-ADP**
|**Analog inputs**|**Analog inputs**|
|---|---|
|Integrated inputs|—<br>2<br>2|
|Connectable temperature sensors|—<br>Pt100 sensor<br>Temp. coefficient 3.850ppm/°C(IEC 751)<br>Thermocouple (K type), isolated type<br>(IEC 584-1 1977,IEC 584-2 1982)|
|Compensated range|—<br>-50–+200 °C<br>-50–+450 °C|
|**Analog outputs**||
|Integrated outputs|2<br>—<br>—|
|Analog output range<br>Voltage<br>Current|0–10 V DC(5 kΩ–1 MΩ)<br>—<br>—|
||4–20 mA(max. 500 Ω)<br>—<br>—|
|**Electrical specifications**||
|Number of channels|2<br>2<br>2|
|Power supply|24 V DC(-15–+10 %),70 mA<br>24 V DC(-15–+20 %),1 W<br>24 V DC(-15–+20 %),1 W|
|**Mechanical specifications**||
|Weight<br>kg|0.05<br>0.07<br>0.07|
|Dimensions (WxHxD)<br>mm|53.1x90x24.5<br>35.5x90x32.5<br>35.5x90x32.5|
Note: the AL2-2DA module can not be used with the AL2-10MR series
85
Accessories
~~**6** _~~
**==> picture [50 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
IT<br>U<br>AL2-EEPROM MADE IN JAPAN<br>**----- End of picture text -----**<br>
## **Memory cassette AL2-EEPROM-2 memory media**
After removing the memory cassette, the former program in the internal memory becomes active again.
With the AL2-EEPROM-2 memory cassettes, a new program can be transferred to the ALPHA 2 controller’s internal system memory from the cassette, or the program of the internal system memory can be saved to the cassette.
The memory cassette AL2-EEPROM-2 is not a memory expansion device, but a medium for data exchange.
If the memory cassette is used, a certain program can be run temporarily by simply plugging the external memory module onto the ALPHA 2.
|**Specifications**|**AL2-EEPROM-2**|
|---|---|
|Memorytype|EEPROM|
|Application|ALPHA 2|
|Memorycapacity|5,000 bytes|
|Function blocks|Max. 200|
|Dimensions(WxHxD)<br>mm|10x45x25|
|||
|**Order information**<br>Art. no.|142526|
**==> picture [33 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
AL-232CAB<br>**----- End of picture text -----**<br>
**==> picture [144 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
CS Ve<br>AL2-GSM-CAB<br>AL2-GSM-CABLOT .24MITSUBISHI ELECTRIC<br>**----- End of picture text -----**<br>
## **Interface cable AL-232CAB**
## **GSM cable AL2-GSM-CAB**
The AL-232CAB is an RS232C interface cable. It connects the ALPHA 2 controller to a personal computer running the programming software for the ALPHA 2 controller.
The GSM AL2-GSM-CAB is an RS232C interface cable and it is used to connect the ALPHA 2 controller to a normal or GSM modem, a personal computer or other serial devices. It can transfer SMS data to a GSM modem for onward transmission to mobile telephones or e-mail addresses. It also permits remote monitoring and remote
The cable ensures a galvanic isolation between the ALPHA 2 controller and the personal computer. The cable AL-232CAB can not be used for any other connection. maintenance.
|Connector<br>~~ee~~|9-pin D-SUB female connector<br>9-pin D-SUB male connector<br>~~ee~~|
|---|---|
|Application|ALPHA 2 <-> PC<br>ALPHA 2 <-> PC,modem|
|Length<br>m|2.5<br>1.5|
|||
|**Order information**<br>Art. no.|87674<br>142528|
Note: The above cables cannot be used with the AL2-10MR series.
86
Base units
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
## **Base units FX5U**
**==> picture [163 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units W W1<br>FX5U-32Mm 150 123<br>FX5U-64Mm 220 193<br>FX5U-80Mm 285 258<br>**----- End of picture text -----**<br>
**==> picture [335 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
�<br>22 W1 8 (0.32")<br> (0.87")<br>W 83 (3.27")<br>)(3.55"<br>80 (3.15") 90<br>**----- End of picture text -----**<br>
All dimensions in mm
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
## **Base units FX5UC**
**==> picture [163 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units W<br>FX5UC-32Mm 42.1<br>FX5UC-64Mm 62.2<br>FX5UC-96Mm 82.3<br>**----- End of picture text -----**<br>
**==> picture [197 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
74 (2.92")<br>42.1 (16.6") 89.1 (3.51")<br>W<br>)(3.55"90<br>**----- End of picture text -----**<br>
All dimensions in mm
~~**7**~~
87
Base units
~~**7**~~
**==> picture [9 x 44] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions<br>**----- End of picture text -----**<br>
## **Base units FX3S**
**==> picture [329 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 75<br>X – 8<br>2 x ø4,5<br>90 82<br>**----- End of picture text -----**<br>
## **Base units FX3G**
**==> picture [327 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>X - 8<br>90 35<br>**----- End of picture text -----**<br>
**==> picture [18 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
ø4,5<br>**----- End of picture text -----**<br>
## **Base units FX3GE**
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
**==> picture [163 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X<br>FX3S-10MR-ES 60<br>FX3S-10MT-ESS 60<br>FX3S-14MR-ES 60<br>FX3S-14MT-ESS 60<br>FX3S-20MR-ES 75<br>FX3S-20MT-ESS 75<br>FX3S-30MR-ES 100<br>FX3S-30MT-ESS 100<br>**----- End of picture text -----**<br>
**==> picture [54 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
**==> picture [163 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X<br>FX3G-14 90<br>FX3G-24 90<br>FX3G-40 130<br>FX3G-60 175<br>**----- End of picture text -----**<br>
**==> picture [54 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
**==> picture [509 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87 Base units X<br>X - 8 FX3GE-24 130<br>FX3GE-40 175<br>ø4,5<br>90 35<br>**----- End of picture text -----**<br>
All dimensions in mm
88
Base units
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Base units FX3GC**
|**Base units**<br>**X**|**Base units**<br>**X**|
|---|---|
|FX3GC-32MT/DSS|35|
**==> picture [119 x 154] intentionally omitted <==**
**==> picture [6 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
X<br>**----- End of picture text -----**<br>
**==> picture [72 x 133] intentionally omitted <==**
All dimensions in mm
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Base units FX3U**
**==> picture [163 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X X1<br>FX3U-16Mmmm 130 103<br>FX3U-32Mmmm 150 123<br>FX3U-48Mmmm 182 155<br>FX3U-64Mmmm 220 193<br>FX3U-80Mmmm 285 258<br>FX3U-128Mmmm 350 323<br>**----- End of picture text -----**<br>
**==> picture [333 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 86<br>22 X1<br>L N S/S 0V 24V X0 X1 X2 X3 X4 X5 X6 X7<br>IN 0347 1256<br>POWER<br>RUN<br>BATT<br>ERROR<br>FX3U -16M OUT 0347 1256<br>Y0 Y0 Y1 Y1 Y2 Y2 Y3 Y3 Y4 Y4 Y5 Y5 Y6 Y6 Y7 Y7<br>R<br>90 80<br>**----- End of picture text -----**<br>
**==> picture [18 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 4.5<br>**----- End of picture text -----**<br>
All dimensions in mm
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Base units FX3UC**
**==> picture [163 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X<br>FX3UC-16MT/DSS 34<br>FX3UC-32MT/DSS 34<br>FX3UC-64MT/DSS 59.7<br>FX3UC-96MT/DSS 85.4<br>**----- End of picture text -----**<br>
**==> picture [119 x 154] intentionally omitted <==**
**==> picture [6 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
X<br>**----- End of picture text -----**<br>
**==> picture [72 x 133] intentionally omitted <==**
All dimensions in mm
~~**7**~~
89
Extension units
~~**7**~~
**==> picture [9 x 44] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions<br>**----- End of picture text -----**<br>
¨ **MELSEC-F series** þ **MELSEC iQ-F series**
## **Input/output modules FX5 (terminal block type)**
**==> picture [252 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
8 (0.32")<br>40 (1.58")<br>83 (3.27")<br>80 (3.15")<br>90 (3.55")<br>**----- End of picture text -----**<br>
All dimensions in mm
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
## **Powered input/output modules FX5**
**==> picture [333 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
140 (5.52") 8 (0.32")<br>150 (5.91") 83 (3.27")<br>)(3.55"<br>80 (3.15") 90<br>**----- End of picture text -----**<br>
All dimensions in mm
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
## **Input/output modules FX5 (connector type)**
FX5-C16EX/D, FX5-C16EX/DS, FX5-C16EYT/D, FX5-C16EYT/DSS FX5-C16EX/D, FX5-C16EX/DS, FX5-C16EYT/D, FX5-C16EYT/DSS FX5-C32EX/D, FX5-C32EX/DS, FX5-C32EYT/D, FX5-C32EYT/DSS
**==> picture [509 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type W<br>FX5-C16EX/D, FX5-C16EX/DS, 14.6<br>FX5-C16EYT/D, FX5-C16EYT/DSS<br>FX5-C32EX/D, FX5-C32EX/DS, 20.1<br>FX5-C32EYT/D, FX5-C32EYT/DSS<br>FX5-C16EX/D, FX5-C16EX/DS, 20.1<br>FX5-C16EYT/D, FX5-C16EYT/DSS<br>74 (2.92") 74 (2.92")<br>20.1 20.1<br>87 (3.43") 87 (3.43")<br>(0.8″) (0.8″) All dimensions in mm<br>)(3.55"90 )(3.55"90<br>**----- End of picture text -----**<br>
90
Extension units
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Adapter modules and extension adapters FX3U**
**==> picture [163 x 63] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX3U-CNV —<br>FX3U-USB —<br>FX3U-485 15.5<br>FX3U-422 —<br>FX3U-232 9.2<br>**----- End of picture text -----**<br>
**==> picture [334 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
74 15.5 17.6 Ø3.2<br>FX3U-4AD-ADP<br>POWER<br>53.5 19.6<br>Ø3.2<br>19.6<br>53.5 X<br>24+ 46.1<br>24-<br>V1+<br>061 90 COM1COM2I1+V2+I2+<br>V3+<br>COM3I3+<br>V4+<br>COM4I4+<br>.1<br>6<br>4<br>**----- End of picture text -----**<br>
**==> picture [54 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Compact extension units and modular extension blocks FX2N**
## **Compact extension units**
**==> picture [224 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>ø4,5<br>IN 0<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>POWER<br>FX -16EX2N<br>IN 0<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>4<br>90 80 35<br>**----- End of picture text -----**<br>
**==> picture [163 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX2N-32Emmm 150<br>FX2N-48Emmm 182<br>FX2N-48ER-UA1/UL 220<br>**----- End of picture text -----**<br>
## **Modular extension blocks**
**==> picture [163 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX2N-8Emmm 43<br>FX2N-16Emmm 40<br>**----- End of picture text -----**<br>
All dimensions in mm
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Modular extension blocks FX2NC**
**==> picture [163 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X Y<br>FX2NC-16EX-DS 14.6 13<br>FX2NC-16EYT-DSS 14.6 13<br>FX2NC-16EX-T-DS 20.2 15<br>FX2NC-16EYR-T-DSS 24.2 15<br>FX2NC-32EX-DS 26.2 13<br>FX2NC-32EYT-DSS 26.2 13<br>**----- End of picture text -----**<br>
**==> picture [230 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 74 Y<br>FX2NC-32EX-DS<br>PowerX0X4X0X4112356723567 X0X4X0X4112356723567<br>90<br>**----- End of picture text -----**<br>
~~**7**~~
All dimensions in mm
91
Special function modules
~~**7**~~
## **Expansion adapters FX5**
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
**==> picture [72 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-4AD-ADP/FX5-4DA-ADP<br>**----- End of picture text -----**<br>
**==> picture [186 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
15.1 8<br>74 15.1<br>17.6<br>)itch<br>p<br> hole<br>90 g 106<br>(Mountin98<br>**----- End of picture text -----**<br>
**==> picture [221 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-232ADP/FX5-485ADP<br>FX5-232ADP<br>15.1 8 8.8<br>74 FX5-485ADP<br>15.1<br>17.6<br>90 98 106<br>**----- End of picture text -----**<br>
**==> picture [54 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## **Expansion boards FX5**
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
**==> picture [506 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-232-BD FX5-485-BD FX5-422-BD-GOT<br>38 6.6 11.6 38 15.1 15.4 38 15.4<br>51.4 51.4 51.4<br>**----- End of picture text -----**<br>
**==> picture [30 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-232-BD<br>**----- End of picture text -----**<br>
**==> picture [54 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## **Special function modules FX3U/FX3UC**
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
**==> picture [252 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>ø4,5<br>POWER<br>FX -4AD3U<br>24 V<br>A / D<br>4<br>90 80 35<br>**----- End of picture text -----**<br>
**==> picture [163 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX3U-2HC 55<br>FX3U-3A-ADP 17.6<br>FX3U-4DA 55<br>FX3U-4AD 55<br>FX3U-4LC 90<br>FX3U-CF-ADP 45<br>FX3U-ENET 55<br>FX3U-CAN 43<br>FX3U-20SSC-H 55<br>FX3U-64CCL-M 55<br>FX3U-64DP-M 43<br>FX3U-1PSU-5V 55<br>FX3UC-4AD 20.2<br>FX3UC-1PS-5V 24.2<br>FX3U-1PG 43<br>FX3U-J1939 43<br>**----- End of picture text -----**<br>
All dimensions in mm
92
Special function modules
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Adapters FX3G**
**==> picture [37 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-485-BD<br>**----- End of picture text -----**<br>
## **FX3G extension adapters**
**==> picture [163 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X X1<br>FX3G-1DA-BD 14.1 15.1<br>FX3G-232-BD 12 5.2<br>FX3G-2AD-BD 14.1 15.1<br>FX3G-422-BD 12 2.9<br>FX3G-485-BD 14.1 15.1<br>FX3G-8AV-BD 12 —<br>**----- End of picture text -----**<br>
**==> picture [67 x 92] intentionally omitted <==**
All dimensions in mm
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Special function modules FX0N/FX2N**
**==> picture [163 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX0N-3A 43<br>FX2N-2DA 43<br>FX2N-2AD 43<br>FX2N-4AD-TC 55<br>FX2N-4AD-PT 55<br>FX2N-1HC 55<br>FX2N-10PG 43<br>FX2N-5A 55<br>FX2N-232-IF 55<br>FX2N-64DNET 43<br>**----- End of picture text -----**<br>
**==> picture [252 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>ø4,5<br>POWER<br>FX -4AD2N<br>24 V<br>A / D<br>4<br>90 80 35<br>**----- End of picture text -----**<br>
~~**7**~~
FX2N-8AD FX2N-32DP-IF-D
**==> picture [301 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
75 75<br>RUN<br>STOP<br>24+ 24- V1+ V2+ I1+ I2+COM1COM2V3+ V4+ I3+ I4+COM3COM4 L NCOM 24 +<br>MITSUBISHI MITSUBISHI<br>FX2N-8AD POWER<br>RUN<br>POWER BF<br>RUN DIA<br>FX2N-32DP-IF-D<br>V6+ I6+ COM6 V8+ I8+ COM8<br>V5+ I5+ COM5 V7+ I7+ COM7<br>ON<br>OFF<br>105 98 90 106 98 90<br>46 32 16 8 4 2 1<br>**----- End of picture text -----**<br>
**==> picture [170 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
90<br>75<br>All dimensions in mm<br>35<br>**----- End of picture text -----**<br>
93
Accessories
## **Bus conversion modules FX5**
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
**==> picture [511 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-CNV-BUS FX5-CNV-BUSC<br>8 8<br>16 83 14.6 74<br>All dimensions in mm<br>90<br>90<br>**----- End of picture text -----**<br>
## **Connector conversion modules FX5**
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
**==> picture [294 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-CNV-IF FX5-CNV-IFC<br>**----- End of picture text -----**<br>
~~**7**~~
**==> picture [509 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
14.6 74 14.6 74<br>All dimensions in mm<br>90 90<br>**----- End of picture text -----**<br>
## ¨ **MELSEC-F series** þ **MELSEC iQ-F series**
## **Extension power supply modules FX5**
**==> picture [33 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX5-1PSU-5V<br>**----- End of picture text -----**<br>
FX5-C1PS-5V
**==> picture [429 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
20.1 74<br>16 8<br>50 83<br>80 90<br>90<br>**----- End of picture text -----**<br>
All dimensions in mm
94
Accessories
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Terminal blocks**
**==> picture [358 x 512] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB-20-S<br>75 50<br>TB-20-C<br>75 50<br>TB-8EX-S<br>75 54<br>TB-8EX-C<br>75 63<br>TB-16EX-S<br>116 62<br>TB-16EX-C<br>116 54<br>45<br>45<br>45<br>45<br>45<br>45<br>**----- End of picture text -----**<br>
~~**7**~~
95
Accessories
~~**7**~~
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Memory cassettes**
**==> picture [48 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-EEPROM-32L<br>**----- End of picture text -----**<br>
**==> picture [62 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-FLROM-16/64/64L<br>**----- End of picture text -----**<br>
**==> picture [74 x 102] intentionally omitted <==**
**==> picture [110 x 37] intentionally omitted <==**
All dimensions in mm
## þ **MELSEC-F series** ¨ **MELSEC iQ-F series**
## **Display panels**
**==> picture [438 x 284] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3S-5DM FX3U-7DM FX3G-5DM<br>11.5<br>8.5 48<br>35 (1.38") 9.6 (0.38")<br>12 (0.48")<br>FX-10DM-E<br>96 32<br>MITSUBISHI<br>DISPLAY MODULE<br>MODEL FX-10DM-E<br>SERIAL 030002 V1.00<br>MITSUBISHI ELECTRIC CORPORATION<br>CLR FNC ENT<br>4,5<br>)<br>(1.36"34.4 )(2.02"<br>51.2<br>35<br>62 53<br>**----- End of picture text -----**<br>
**==> picture [10 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
86<br>**----- End of picture text -----**<br>
All dimensions in mm
96
ALPHA series
~~**7**~~
## **ALPHA series**
AL2-14Ml-l, AL2-24Ml-l
**==> picture [446 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
6,0 6,0<br>ĐĐ Đ Đ ĐĐĐĐĐĐĐĐ Đ (A) Đ Đ (B) DC INPUT + - (A) (B) 1 2 3 4 5 DC INPUT 6 7 8 9 10 11 12 13 14 15<br>ĐĐĐ<br>MITSUBISHI POWER24V DC<br>MITSUBISHI<br>ĐĐ ESC ESC<br>+ +<br>- -<br>OK OK<br>AL2-10MR-D AL2-24MR-D<br>RELAY<br>OUT1 OUT2 OUT3 OUT4 OUTPUTOUT 5 6 7 8 9<br>6,0 6,0<br>52,0 71,2 124,6<br>4,0 4,0<br>090, 090,<br>4,0 4,0<br>**----- End of picture text -----**<br>
AL2-4EYl, AL2-2DA
AL2-2PT-ADP, AL2-2TC-ADP
**==> picture [315 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
53,1 24,5 35,5 33,5<br>+ - V1+ V1- V2+ V2-<br>+ EI1 - + EI2 - POWER24V DC OUTPUTCH1 0~10VCH2<br>MITSUBISHI<br>MITSUBISHI POWER<br>200°C -50°CCH1 Line 200°C CH2-50°C Line<br>AL2-2PT-ADP<br>4EX PT100 -50~200°C<br>+ EI3 - + EI4 - CH1 CH2<br>L1+ L1- I1- L2+ L2- I2-<br>90<br>90<br>4<br>**----- End of picture text -----**<br>
All dimensions in mm
97
Programming
~~**8**~~
## **MELSOFT – programming and documentation software for standard personal computers**
With the MELSOFT software family Mitsubishi Electric offers efficient software packages helping to reduce programming and setup times to a high degree. The MELSOFT software family provides instant access, direct communications, compatibility, and open exchange of variables. The MELSOFT family comprises:
Programming packages AL-PCS/WIN and GX Works2/GX Works2 FX
Various development software for operator terminals (please refer to the technical catalogue HMI)
AL-PCS/WIN is recommended as a cost-effective beginners package for the ALPHA series. This package offers a quick and easy introduction to programming.
GX Works2 is the right decision for a universal programming package. In addition to the FX family, the MELSEC L series and the MELSEC System Q can be programmed.
For detailed information please order our separate MELSOFT brochure.
Software for a dynamic data exchange like MX Change
## ~~**ALPHA programming software**~~
## **AL-PCS/WIN programming software**
All controllers of the ALPHA series can be programmed with the MS Windows® software AL-PCS/WIN. Programming the ALPHA with this software is very easy and is done by placing the different program elements on a graphical programming environment. The connections (wiring) between the inputs, function blocks, and outputs are drawn graphically by mouse
click to build the logic. By this, programs with up to 200 function blocks can be created, where each single function in a program can be used as many times as desired.
A complete documentation of the program can be created directly from AL-PCS/WIN.
|**Software**<br>**(AL-PCS/WIN)**<br>Series<br>Alpha series<br>~~Oe~~|**Software**<br>**(AL-PCS/WIN)**<br>Series<br>Alpha series<br>~~Oe~~|
|---|---|
|Language|7 languages(English/German/French/Italian/Spanish/Swedish/Russian)|
|Einsetzbar bei|Windows 95/98/ME/NT/2000/XP/Vista/7|
|||
|**Order information**|Free download from the webpage|
Note: The AL-PCS/WIN software can be downloaded free of charge
98
Programming
~~**8**~~
## **PLC programming software**
## ~~**GX Works2/GX Works2 FX**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** ¨ **FX5U** ¨ **FX5UC**
GX Works2 supports all PLC of the MELSEC System Q, L and FX3 series and offers numerous functions to faciliate programming work and support the user. GX Works2 FX has the same functionality as GX Works2 but just for FX3 PLC´s.
The following programming languages are available:
- z ST (Structured Text)
- z SFC (Sequential Function Chart)
- z LD (Ladder Diagram)
- z FBD (Function Block Diagram)
- z IL (Instruction List) – planned capability
## **Main features**
- z Integrated parameterization of special function modules (analog, temperature, positioning, counter, network)
- z Use of program and function block libraries save time for programming and minimizes errors.
- z Integrated simulation allows offline testing of the software and the configuration.
- z Comprehensive diagnostics and debugging functions support the user in troubleshooting and fault clearance.
- z Revision verification and restoration makes it possible to restore old program versions or to compare with programs from the PLC.
- z GX Works2 is compatible with GX Developer and GX IEC Developer projects (as far as the editors are supported)
|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>OOOO|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>OOOO|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>OOOO|
|---|---|---|
|GX Works2 FX V01-2L0C-E<br>GX Works2 FX V01-2L0C-E-INTRODUCTION|MELSEC FX3S, FX3G, FX3GC, FX3GE, FX3U, FX3UC<br>English<br>DVD|255804<br>256745|
||||
|GX Works2 V01-2L0C-E||234630|
|GX Works2 V01-5L0C-E||234631|
|GX Works2 V01-2L0C-E-UPGRADE|All MELSEC PLCs (except MELSEC iQ-R/iQ-F),<br>English<br>DVD|234632|
|GX Works2 V01-5L0C-E-UPGRADE<br>GX Works2 V01-2L0C-E-INTRODUCTION||234634<br>234789|
||||
|GX Works2 V01-2L0C-G<br>GX Works2 V01-5L0C-G<br>GX Works2 V01-2L0C-G-INTRODUCTION<br>Accessory|All MELSEC PLCs (except MELSEC iQ-R/iQ-F),<br>German<br>DVD<br>Programmingcable FX-USB-AW|244876<br>244877<br>244878<br>165288|
## ~~**GX Works3**~~
## þ **FX3S** þ **FX3G** þ **FX3GC** þ **FX3GE** þ **FX3U** þ **FX3UC** þ **FX5U** þ **FX5UC**
GX Works3 supports the MELSEC iQ-F (and iQ-R) series and offers numerous functions to faciliate programming work and support the user.
**==> picture [18 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
Drag & Drop<br>**----- End of picture text -----**<br>
Simply drag & drop when adding a module
The main IEC languages are supported by GX Works3:
- z ST (Structured Text)
- z FBD (Function Block Diagram)
- z LD (Ladder Diagram)
## **Main features**
- z Achieving an easy and intuitive programming by only making "selections" in a graphical environment with module configuration diagram and module label/module FB.
- z Supporting various applications (parameter settings of simple motion module, creation of positioning data, parameter setting and servo adjustments of servo amplifier).
- z Enabling transmitting/receiving of the data between an external device and the CPU module by matching the protocol of the external device (Communication protocol support function).
|GX Works3 V01-2L0C-E|English<br>CD<br>284378<br>English<br>CD<br>284379<br>English<br>CD<br>286219<br>English,German<br>CD<br>304614<br>English<br>CD<br>286220<br>English,German<br>CD<br>304645|
|---|---|
|GX Works3 V01-5L0C-E||
|GX Works3 V01-2L0C-E-UPGRADE||
|GX Works3 V01-2L0C-G||
|GX Works3 V01-5L0C-E-UPGRADE||
|GX Works3 V01-5L0C-G||
99
Programming
## **Software for Profibus networks**
## ~~**GX Configurator DP**~~
The GX Configurator DP is a user friendly configurations software for the open network Profibus DP.
The software package is a 32 bit application and runs under all Windows versions.
Configuration of all Profibus DP modules for the MELSEC Ans/QnAS and A/Q series and also the FX family is possible.
Due to the supported extended user parameters of a GSD file, easy parameter setting of Profibus DP slave devices is possible even for third-party devices.
The new GX Configurator DP enables the download of all configuration data via an overriding network.
All Profibus modules are configured via the backside bus.
|**Software**|**GX Configurator DP V07-1L0C-M**|
|---|---|
|Supported Profibus DP master modules<br>for the Mitsubishi Electric MELSEC series|A1SJ71PB92D, AJ71PB92D, QJ71PB92D|
|Language|English/German|
|Disk type|CD ROM|
|||
|**Order information**<br>Art. no.|231731|
|||
|**Accessory**|Programmingcable FX-USB-AW,art. no.: 165288|
## ~~**FX Configurator FP**~~
~~**8**~~
FX Configurator-FP is beneficial for setting up table operation information, servo amplifier parameters and positioning parameters for the FX3U-SSC-H positioning module. Positioning operations and their associated parameters (speeds, addresses, torque limits etc.) can be monitored and tested with the integrated monitor and test functions.
Control patterns from simple to complicated combinations of positioning commands can easily be configured with new methods.
The software runs under all Windows® versions.
|**Software**|**FX Configurator FP V0100-1LOC-E**|
|---|---|
|Supported modules for the Mitsubishi Electric<br>MELSEC series|FX3U-20SSC-H|
|Language|English|
|Disk type|CD ROM|
|||
|**Order information**<br>Art. no.|189283|
|||
|**Accessory**|Programmingcable FX-USB-AW,art. no.: 165288|
100
Programming
~~**8**~~
## ~~**Hand-held programming unit**~~
## **FX-30P programming unit**
can be downloaded on a PC then installed via the USB port. PLC programs on the PC can also be transferred via USB, eliminating the need for peripheral devices.
The FX-30P is a small, industrial programming can be downloaded on a PC then installed via and maintenance tool for the FX Series. This unit the USB port. PLC programs on the PC can also can perform program uploads/downloads and be transferred via USB, eliminating the need for store up to 15 programs in its internal memory. peripheral devices. Keywords can be registered, deleted or canceled Note: FX-30P firmware and program downloads in applicable PLCs. Program monitoring and from a PC via the embedded USB port available is data device adjustment functionality is also in firmware versions 1.10 and later. available. To stay up to date the latest firmware ~~a~~ **Specifications FX-30P**
|**Specificationspecificationsecifications**<br>~~a~~|~~a~~|**FX-30P**<br>~~a~~|
|---|---|---|
|Applicable for<br>~~a~~|~~a~~|Base units FX1S,FX1N,FX3G,FX2N,FX3U,FX3UC<br>~~a~~|
|Ambient temperature||0–40 °C|
|Ambient relative humidity (non-condensing)||5–95 %|
|Power supply||5 V DC ±5 %/155 mA(from main unit)|
|Display||LCD(with backlight)|
|Character display||21x8|
|Keyboard||35|
|Memory|Program capacity|Built-in RAM: 64K steps for program monitoring and modification RAM retention<br>(for about fiveyears,ambient temperature 25 C(77 F))bybattery.<br>Built-in flash memory ROM: Up to 15 programs can be stored in the built-in flash memory<br>ROM. Allowable number of writes: 100,000 times|
||HPP held data|Display language setting (Japanese, English or Chinese), contrast, buzzer sound volume,<br>brightness adjustment, screen saver and HPP protect key (saved in the built-in flash<br>memory)|
|Cable||FX-20P-CAB0|
|Weight|kg|0.3|
|Dimensions (WxHxD)|mm|87x170x30|
||||
|**Order information**|Art. no.|221271|
101
Notes
102
Certifications
## **MELSEC iQ-F series**
**==> picture [250 x 683] intentionally omitted <==**
**----- Start of picture text -----**<br>
CE uL Ship approvals<br>Module type EMC LVD* cUL KC ABS DNV LR GL BV RINA NK KR<br>FX5U base units<br>FX5U-32MR/DS P P P P — — — — — — — —<br>FX5U-32MR/ES P P P P P P P P P P P P<br>FX5U-32MT/DS P p P P — — — — — — — —<br>FX5U-32MT/DSS P p P P — — — — — — — —<br>FX5U-32MT/ES P P P P P P P P P P P P<br>FX5U-32MT/ESS P P P P P P P P P P P P<br>FX5U-64MR/DS P P P P — — — — — — — —<br>FX5U-64MR/ES P P P P P P P P P P P P<br>FX5U-64MT/DS P p P P — — — — — — — —<br>FX5U-64MT/DSS P p P P — — — — — — — —<br>FX5U-64MT/ES P P P P P P P P P P P P<br>FX5U-64MT/ESS P P P P P P P P P P P P<br>FX5U-80MR/DS P P P P — — — — — — — —<br>FX5U-80MR/ES P P P P P P P P P P P P<br>FX5U-80MT/DS P p P P — — — — — — — —<br>FX5U-80MT/DSS P p P P — — — — — — — —<br>FX5U-80MT/ES P P P P P P P P P P P P<br>FX5U-80MT/ESS P P P P P P P P P P P P<br>FX5UC base units<br>FX5UC-32MT/D P p P P P P P P P P P P<br>FX5UC-32MT/DSS P p P P P P P P P P P P<br>FX5UC-64MT/D P p P P P P P P P P P P<br>FX5UC-64MT/DSS P p P P P P P P P P P P<br>FX5UC-96MT/D P p P P P P P P P P P P<br>FX5UC-96MT/DSS P p P P P P P P P P P P<br>FX5 I/O modules (extension cable type)<br>FX5-8EX/ES P p P P P P P P P P P P<br>FX5-16ER/ES P P P P — — — — — — — —<br>FX5-16ET/ES P p P P — — — — — — — —<br>FX5-16ET/ESS P p P P — — — — — — — —<br>FX5-16EX/ES P p P P P P P P P P P P<br>FX5-8EYR/ES P P P P P P P P P P P P<br>FX5-8EYT/ES P p P P P P P P P P P P<br>FX5-8EYT/ESS P p P P P P P P P P P P<br>FX5-16EYR/ES P P P P P P P P P P P P<br>FX5-16EYT/ES P p P P P P P P P P P P<br>FX5-16EYT/ESS P p P P P P P P P P P P<br>FX5-16ET/ES-H P p P P P P P P P P P P<br>FX5-16ET/ESS-H P p P P P P P P P P P P<br>FX5-32ER/ES P P P P P P P P P P P P<br>FX5-32ET/ES P P P P P P P P P P P P<br>FX5-32ET/ESS P P P P P P P P P P P P<br>FX5-32ER/DS P P P P — — — — — — — —<br>FX5-32ET/DS P p P P — — — — — — — —<br>FX5-32ET/DSS P p P P — — — — — — — —<br>FX5 I/O module (extension connector type)<br>FX5-C16EX/D P p P P P P P P P P P P<br>FX5-C16EX/DS P p P P P P P P P P P P<br>FX5-C32EX/D P p P P P P P P P P P P<br>FX5-C32EX/DS P p P P P P P P P P P P<br>FX5-C16EYT/D P p P P P P P P P P P P<br>FX5-C16EYT/DSS P p P P P P P P P P P P<br>FX5-C32EYT/D P p P P P P P P P P P P<br>FX5-C32EYT/DSS P p P P P P P P P P P P<br>FX5-C32ET/D P p P P P P P P P P P P<br>FX5-C32ET/DSS P p P P P P P P P P P P<br>FX5 intelligent function module<br>FX5-40SSC-S P — P P — — — — — — — —<br>FX5-80SSC-S P — P P — — — — — — — —<br>FX5-CCLIEF P p P P — — — — — — — —<br>FX5-20PG-P P — P P — — — — — — — —<br>FX5-CCL-MS P — P P — — — — — — — —<br>FX5-ASL-M P — P P — — — — — — — —<br>**----- End of picture text -----**<br>
**==> picture [250 x 547] intentionally omitted <==**
**----- Start of picture text -----**<br>
CE uL Ship approvals<br>Module type EMC LVD* cUL KC ABS DNV LR GL BV RINA NK KR<br>FX5 extension power supply module<br>FX5-1PSU-5V P P P P P P P P P P P P<br>FX5-C1PS-5V P p P P P P P P P P P P<br>FX5 bus conversion module<br>FX5-CNV-BUS P p P P P P P P P P P P<br>FX5-CNV-BUSC P p P P P P P P P P P P<br>FX5 connector conversion module<br>FX5-CNV-IF P p P P P P P P P P P P<br>FX5-CNV-IFC P p P P P P P P P P P P<br>FX5 expansion adapter<br>FX5-4AD-ADP P p P P P P P P P P P P<br>FX5-4DA-ADP P p P [a] P P P P P P P P P<br>FX5-232ADP P p P P P P P P P P P P<br>FX5-485ADP P p P P P P P P P P P P<br>FX5U expansion board<br>FX5-232-BD P p — P P P P P P P P P<br>FX5-485-BD P p — P P P P P P P P P<br>FX5-422-BD-GOT P p — P P P P P P P P P<br>FX5 special function module<br>FX5-4AD-PT-ADP P p P P — — — — — — — —<br>FX5-4AD-TC-ADP P p P P — — — — — — — —<br>FX5-8AD P — P P — — — — — — — —<br>FX5-4LC P — P P — — — — — — — —<br>Terminal module<br>FX-16E-TB — — P p — — — — — — — —<br>FX-32E-TB — — P p — — — — — — — —<br>FX-16EYR-TB — — P p — — — — — — — —<br>FX-16EYS-TB — — — — — — — — — — — —<br>FX-16EYT-TB — — P p — — — — — — — —<br>FX-16E-TB/UL — — P p — — — — — — — —<br>FX-32E-TB/UL — — P p — — — — — — — —<br>FX-16EYR-ES-TB/UL — — P p — — — — — — — —<br>FX-16EYS-ES-TB/UL — — P p — — — — — — — —<br>FX-16EYT-ES-TB/UL — — P p — — — — — — — —<br>FX-16EYT-ESS-TB/UL — — P p — — — — — — — —<br>Extended extension cable<br>FX5-30EC P p P P — — — — — — — —<br>FX5-65EC P p P P — — — — — — — —<br>Connector conversion adapter<br>FX5-CNV-BC P p P P P P P P P P P P<br>FX3 intelligent function module<br>FX3U-4AD P p P P — — — — — — — —<br>FX3U-4DA P p P P — — — — — — — —<br>FX3U-4LC P p P P — — — — — — — —<br>FX3U-1PG P p P P — — — — — — — —<br>FX3U-2HC P p P P — — — — — — — —<br>FX3U-16CCL-M P p P P — — — — — — — —<br>FX3U-64CCL P p P P — — — — — — — —<br>FX3U-128ASL-M P p P P — — — — — — — —<br>FX3 extension power supply module<br>FX3U-1PSU-5V P P P P — — — — — — — —<br>**----- End of picture text -----**<br>
1 Supported by manufacturing serial number 1660001 and later
P = comply, p = no need to comply
*LVD = Low Voltage Directive
103
Certifications
## **ALPHA and MELSEC-F series**
**==> picture [512 x 654] intentionally omitted <==**
**----- Start of picture text -----**<br>
CE uL Ship approvals CE uL Ship approvals<br>Module type EMC LVD* cUL KC ABS DNV LR GL BV RINA NK KR Module type EMC LVD* cUL KC ABS DNV LR GL BV RINA NK KR<br>ALPHA 2 base units FX3GE base units<br>AL2-10MR-A P P P — — — — — — — — — FX3GE-24MR/DS P P P — — — — — — — — —<br>AL2-10MR-D P P P — — — — — — — — — FX3GE-24MR/ES P P P — — — — — — — — —<br>AL2-14MR-A P P P — — P — — — — — — FX3GE-24MT/DS P p P — — — — — — — — —<br>AL2-14MR-D P P P — — P — — — — — — FX3GE-24MT/DSS P p P — — — — — — — — —<br>AL2-24MR-A P P P — — P — — — — — — FX3GE-24MT/ES P P P — — — — — — — — —<br>AL2-24MR-D P P P — — P — — — — — — FX3GE-24MT/ESS P P P — — — — — — — — —<br>ALPHA extension modules FX3GE-40MR/DS P P P — — — — — — — — —<br>AL2-2DA P P P — — — — — — — — — FX3GE-40MR/ES P P P — — — — — — — — —<br>AL2-2PT-ADP P — P — — — — — — — — — FX3GE-40MT/DS P p P — — — — — — — — —<br>AL2-2TC-ADP P — P — — — — — — — — — FX3GE-40MT/DSS P p P — — — — — — — — —<br>AL2-4EX-A2 P P P — — P — — — — — — FX3GE-40MT/ES P P P — — — — — — — — —<br>AL2-4EX P P P — — P — — — — — — FX3GE-40MT/ESS P P P — — — — — — — — —<br>AL2-4EYR P P P — — P — — — — — — FX3GC base units<br>AL2-4EYT P P P — — P — — — — — — FX3GC-32MT/D P p P P — — — — — — — —<br>AL2-ASI-BD P P P — — P — — — — — — FX3GC-32MT/DSS P p P P — — — — — — — —<br>FX3S base units FX3U base units<br>FX3S-10MR/DS P p P P P P P P P — P — FX3U-16MR/DS P P P P P P P P P P P P<br>FX3S-10MR/ES P P P P P P P P P — P — FX3U-16MR/ES P P P P P P P P P P P P<br>FX3S-10MT/DS P p P P P P P P P — P — FX3U-16MT/DSS P p P P P P P P P P P P<br>FX3S-10MT/DSS P p P P P P P P P — P — FX3U-16MT/ESS P P P P P P P P P P P P<br>FX3S-10MT/ES P P P P P P P P P — P — FX3U-32MR/DS P P P P P P P P P P P P<br>FX3S-10MT/ESS P P P P P P P P P — P — FX3U-32MR/ES P P P P P P P P P P P P<br>FX3S-14MR/DS P p P P P P P P P — P — FX3U-32MT/DSS P p P P P P P P P P P P<br>FX3S-14MR/ES P P P P P P P P P — P — FX3U-32MT/ESS P P P P P P P P P P P P<br>FX3S-14MT/DS P p P P P P P P P — P — FX3U-48MR/DS P P P P P P P P P P P P<br>FX3S-14MT/DSS P p P P P P P P P — P — FX3U-48MR/ES P P P P P P P P P P P P<br>FX3S-14MT/ES P P P P P P P P P — P — FX3U-48MT/DSS P p P P P P P P P P P P<br>FX3S-14MT/ESS P P P P P P P P P — P — FX3U-48MT/ESS P P P P P P P P P P P P<br>FX3S-20MR/DS P p P P P P P P P — P — FX3U-64MR/DS P P P P P P P P P P P P<br>FX3S-20MR/ES P P P P P P P P P — P — FX3U-64MR/ES P P P P P P P P P P P P<br>FX3S-20MT/DS P p P P P P P P P — P — FX3U-64MT/DSS P p P P P P P P P P P P<br>FX3S-20MT/DSS P p P P P P P P P — P — FX3U-64MT/ESS P P P P P P P P P P P P<br>FX3S-20MT/ES P P P P P P P P P — P — FX3U-80MR/DS P P P P P P P P P P P P<br>FX3S-20MT/ESS P P P P P P P P P — P — FX3U-80MR/ES P P P P P P P P P P P P<br>FX3S-30MR/DS P p P P P P P P P — P — FX3U-80MT/DSS P p P P P P P P P P P P<br>FX3S-30MR/ES P P P P P P P P P — P — FX3U-80MT/ESS P P P P P P P P P P P P<br>FX3S-30MR/ES-2AD P P P P P P P P P — P — FX3U-128MR/ES P P P P P P P P P P P P<br>FX3S-30MT/DS P p P P P P P P P — P — FX3U-128MT/ESS P P P P P P P P P P P P<br>FX3S-30MT/DSS P p P P P P P P P — P — FX3UC base units<br>FX3S-30MT/ES P P P P P P P P P — P — FX3UC-16MT/DSS P p P P P P P P P P — —<br>FX3S-30MT/ES-2AD P p P P P P P P P — P — FX3UC-32MT/DSS P p P P P P P P P P — —<br>FX3S-30MT/ESS P P P P P P P P P — P — FX3UC-64MT/DSS P p P P P P P P P P — —<br>FX3S-30MT/ESS-2AD P p P P P P P P P — P — FX3UC-96MT/DSS P p P P P P P P P P — —<br>FX3G base units<br>P = comply, p = no need to comply<br>FX3G-14MR/DS P P P P P P P P P P P — *LVD = Low Voltage Directive<br>FX3G-14MR/ES P P P P P P P P P P P —<br>FX3G-14MT/DSS P p P P P P P P P P P —<br>FX3G-14MT/ESS P P P P P P P P P P P —<br>FX3G-24MR/DS P P P P P P P P P P P —<br>FX3G-24MR/ES P P P P P P P P P P P —<br>FX3G-24MT/DSS P p P P P P P P P P P —<br>FX3G-24MT/ESS P P P P P P P P P P P —<br>FX3G-40MR/DS P P P P P P P P P P P —<br>FX3G-40MR/ES P P P P P P P P P P P —<br>FX3G-40MT/DSS P p P P P P P P P P P —<br>FX3G-40MT/ESS P P P P P P P P P P P —<br>FX3G-60MR/DS P P P P P P P P P P P —<br>FX3G-60MR/ES P P P P P P P P P P P —<br>FX3G-60MT/DSS P p P P P P P P P P P —<br>FX3G-60MT/ESS P P P P P P P P P P P —<br>**----- End of picture text -----**<br>
104
Certifications
**==> picture [514 x 683] intentionally omitted <==**
**----- Start of picture text -----**<br>
CE uL Ship approvals CE uL Ship approvals<br>Module type EMC LVD* cUL KC ABS DNV LR GL BV RINA NK KR Module type EMC LVD* cUL KC ABS DNV LR GL BV RINA NK KR<br>FX2N extension units FX3UC special function blocks<br>FX2N-32ER-ES/UL P P P P P P P P P P — P FX3UC-1PS-5V P p P P P P P P P P — —<br>FX2N-32ET-ESS/UL P P P P P P P P P P — P FX3UC-4AD P p P P — — — — — — — —<br>FX2N-48ER-DS P P P P P P — — — — — P Adapter boards<br>FX2N-48ER-ES/UL P P P P P P P P P P — P FX3G-1DA-BD P p — P P P P P P P P —<br>FX2N-48ET-DSS P p P P P P — — — P — P FX3G-2AD-BD P p — P P P P P P P P —<br>FX2N-48ET-ESS/UL P P P P P P P P P P — P FX3G-8AV-BD P p — p P P P P P P P —<br>FX2N extension blocks FX3G-232-BD P p — P P P P P P P P —<br>FX2N-8ER-ES/UL P P P p — P — P — — — — FX3G-422-BD P p — p P P P P P P P —<br>FX2N-8EX-ES/UL P P P p — P — P — — — — FX3G-485-BD P p — p P P P P P P P —<br>FX2N-8EYR-ES/UL P P P p — P — P — — — — FX3U-232-BD P p — P P P P P P P P P<br>FX2N-8EYT-ESS/UL P P P p — P — P — — — — FX3U-422-BD P p — P P P P P P P P P<br>FX2N-16EX-ES/UL P p P p P P P P P P P P FX3U-485-BD P p — P P P P P P P P P<br>FX2N-16EYR-ES/UL P p P p P P P P P P P P FX3U-CNV-BD P p — p P P P P P P P P<br>FX2N-16EYT-ESS/UL P p P p P P P P P P P P FX3U-USB-BD P p — P P P P P P P P P<br>FX2N special function modules FX3S-CNV-ADP P p P p P P P P P P P P<br>FX2N-1HC P p P P P P P P P P — P FX3G-CNV-ADP P p P p P P P P P — P —<br>FX2N-2AD P p P P P — — P — — P P Accessories<br>FX2N-2DA P p P P P — — P — — P P ALPHA POWER 24 P P P — — — — — — — — —<br>FX2N-5A P p P P — — — P P P — — FX-10DM-E P p — P — — — — — — — —<br>FX2N-8AD P p P P — — — P P P P — FX-232AWC-H P p — P — — — — — — — —<br>FX2N-10PG P p P P — — — — — — — — FX-USB-AW P p — P — — — — — — — —<br>FX2N-32CCL P p — P — — — — — — — — FX2N-CNV-BC P p — p — — — — — — — —<br>FX2N-32DP-IF-D P P P P — — — — — — — — FX2NC-CNV-IF P p — — — — P — — — — —<br>FX2N-64DNET P p P P — — — — — — — — FX3G-5DM P p — P P P P P P P P —<br>FX2N-232IF P p — P P P P P P P — — FX3U-1PSU-5V P P P P — — — — — — — —<br>FX2NC extension blocks FX3U-32BL — — — — — — — — — — — —<br>FX2NC-16EX-DS P p P p P P P — — — — — FX3U-7DM P p — P P P P P P P P P<br>FX2NC-16EX-T-DS P p P p P P P — — — — — FX3U-7DM-HLD — p — p — — — — — — — —<br>FX2NC-16EYR-T-DS P P P p P P P — — — — — FX3UC-1PS-5V — — — — — P — — — — — —<br>FX2NC-16EYT-DSS P p P p P P P — — — — — Memory cassettes<br>FX2NC-32-EX-DS P p P p P P P — — — — — FX3G-EEPROM-32L P p — p P P P P P P P —<br>FX2NC special function modules FX3U-FLROM-16 P p — p P P P P P P P P<br>FX2NC-1HC P P P P — — — — — — — — FX3U-FLROM-64 P p — p P P P P P P P P<br>FX3U special function modules FX3U-FLROM-64L P p — p P P P P P P P P<br>FX3U-2HC P p P P — — — — — — — —<br>P = comply, p = no need to comply<br>FX3U-2HSY-ADP P p P P P P P P P P P P<br>*LVD = Low Voltage Directive<br>FX3U-3A-ADP P p P P — — — — — — — —<br>FX3U-4AD P p P P — — — — — — — —<br>FX3U-4AD-ADP P p P P P P P P P P P P<br>FX3U-4AD-PNK-ADP P p P P — — — — — — — —<br>FX3U-4AD-PT-ADP P p P P P P P P P P P P<br>FX3U-4AD-PTW-ADP P p P P — — — — — — — —<br>FX3U-4AD-TC-ADP P p P P P P P P P P P P<br>FX3U-4DA P p P P — — — — — — — —<br>FX3U-4DA-ADP P p P P P P P P P P P P<br>FX3U-4HSX-ADP P p P P P P P P P P P P<br>FX3U-4LC P p P P — — — — — — — —<br>FX3U-20SSC-H P p P P — — — — — — — —<br>FX3U-232ADP-MB P p P P P P P P P P P P<br>FX3U-485ADP-MB P p P P P P P P P P P P<br>FX3U-CF-ADP P p P P — — — — — — — —<br>FX3U-ENET-ADP P p P P — — — — — — — —<br>FX3U-ENET P p P P P P P P — — — —<br>FX3U-CAN P p P — P P P P P P P —<br>FX3U-16CCL-M P p P P — — — — — — — —<br>FX3U-64CCL P p P P — — — — — — — —<br>FX3U-64DP-M P p P — P P — P — — — —<br>FX3U-J1939 P p P — P P P P P P P —<br>FX3U-1PG P p P P — — — — — — — —<br>FX3G interface adapter<br>FX3G-CNV-ADP P p P p P P P P P P P —<br>FX3S interface adapter<br>FX3S-CNV-ADP P p P p — — — — — — — —<br>**----- End of picture text -----**<br>
105
Index
## **M**
## **P**
|**M**||**P**|**P**|
|---|---|---|---|
|MELSEC-F series|MELSEC iQ-F series|Programming||
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74||ALPHA programming software. . . . . . . . . . . . . . . . . . . . . . .98|
|Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55|Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55||Hand-held programming unit . . . . . . . . . . . . . . . . . . 101|
|Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104<br>Communication modules . . . . . . . . . . . . . . . . . . . . . . . 68<br>Configuration<br>FX3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br>FX3GC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br>FX3GE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br>FX3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br>FX3U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8|Base units<br>FX5U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br>FX5UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br>Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103<br>Communication modules . . . . . . . . . . . . . . . . . . . . . . . 68<br>Configuration<br>FX5U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br>FX5UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16||MELSOFT – programming and documentation<br>software for standard personal computers . . . . . . . . 98<br>PLC programming software . . . . . . . . . . . . . . . . . . . . . 99<br>GX Works2/GX Works2 FX . . . . . . . . . . . . . . . . . . . . . 99<br>GX Works3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99<br>Software for Profibus networks . . . . . . . . . . . . . . . . . 100<br>FX Configurator FP . . . . . . . . . . . . . . . . . . . . . . . . . . 100<br>GX Configurator DP . . . . . . . . . . . . . . . . . . . . . . . . . 100|
|FX3UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br>Data logger module . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87<br>High-speed counter modules . . . . . . . . . . . . . . . . . . . . 59|**S**||
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br>Extension adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br>High-speed counter adapters . . . . . . . . . . . . . . . . . . . . 60<br>High-speed counter modules . . . . . . . . . . . . . . . . . . . . 59<br>Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73<br>I/O extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br>Network modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br>Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 60|Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73<br>I/O extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<br>Powered extension units . . . . . . . . . . . . . . . . . . . . . 50<br>Unpowered extension modules . . . . . . . . . . . . . . . . 52<br>Network modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br>Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br>Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4<br>Simple Motion modules . . . . . . . . . . . . . . . . . . . . . . . . 61|System description FX series<br>Calculation of the power consumption . . . . . . . . . . . . 18<br>Components FX PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7<br>Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br>Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4<br>Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6<br>**T**||
|Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5|Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99|The ALPHA 2 series||
|Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99<br>Special functions<br>FX control solutions . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br>Specifications<br>FX3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br>FX3GC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br>FX3GE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br>FX3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br>FX3U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br>FX3UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br>Temperature control modules . . . . . . . . . . . . . . . . . . . 58<br>Unit components<br>FX3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br>FX3GC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39<br>FX3GE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37|Special functions<br>Advanced motion control . . . . . . . . . . . . . . . . . . . . . 24<br>Basic positioning control . . . . . . . . . . . . . . . . . . . . . 23<br>Battery-less and maintenance-free . . . . . . . . . . . . 22<br>Built-in analog inputs/outputs<br>(with alarm output) . . . . . . . . . . . . . . . . . . . . . . . . . 20<br>Built-in Ethernet port . . . . . . . . . . . . . . . . . . . . . . . . 19<br>Built-in positioning (200 kpps, 4 axes built in) +<br>Positioning 2 axes (200 kpps, 2 axes) . . . . . . . . . . . 22<br>Built-in RS485 port (with Modbus® function) . . . . 20<br>Built-in SD card slot . . . . . . . . . . . . . . . . . . . . . . . . . 20<br>Data logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21<br>High-speed system bus communication . . . . . . . . 19<br>Intuitive programming environment . . . . . . . . . . . 21<br>Security functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 21||Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86<br>Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br>Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97<br>Extension modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85<br>Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98<br>Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84<br>Unit components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82|
|FX3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br>FX3U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br>FX3UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46|Simple motion modules<br>(4-axis/8-axis control modules) . . . . . . . . . . . . . . . 23<br>Specifications<br>FX5U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28|||
||FX5UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31|||
||Temperature control modules . . . . . . . . . . . . . . . . . . . 58|||
||Unit components|||
||FX5U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26|||
||FX5UC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29|||
106
**Your solution partner**
## **Your solution partner**
Low voltage: MCCB, MCB, ACB
Medium voltage: VCB, VCC
Power monitoring, energy management
Mitsubishi Electric offers a wide range of automation equipment from PLCs and HMIs to CNC and EDM machines
Compact and Modular Controllers
## **A name to trust**
Since its beginnings in 1870, some 45 companies use the Mitsubishi name, covering a spectrum of finance, commerce and industry.
The Mitsubishi brand name is recognized around the world as a symbol of premium quality.
Mitsubishi Electric Corporation is active in space development, transportation, semi-conductors, energy systems, communications and information processing, audio visual equipment and home electronics, building and energy management and automation systems, and has 237 factories and laboratories worldwide in over 121 countries.
This is why you can rely on Mitsubishi Electric automation solution - because we know first hand about the need for reliable, efficient, easy-to-use automation and control in our own factories.
As one of the world’s leading companies with a global turnover of over 4 trillion Yen (over $40 billion), employing over 100,000 people, Mitsubishi Electric has the resource and the commitment to deliver the ultimate in service and support as well as the best products.
Inverters, Servos and Motors
Visualization: HMIs, Software, MES connectivity
Numerical Control (NC)
Robots: SCARA, Articulated arm
Processing machines: EDM, Lasers, IDS iam, Air-conditioning, Photovoltaic, EDS
17
## **Global Partner. Local Friend.**
## **European Offices**
|**ean Offices**|||||||
|---|---|---|---|---|---|---|
|**y**<br>**i Electric Europe B.V.**<br>Electric-Platz 1<br>atingen<br>(0)2102 / 486-0|**Czech Rep.**<br>**Mitsubishi Electric Europe B.V.**<br>Pekařská 621/7<br>CZ-155 00 Praha 5<br>Phone: +420 255 719 200|**France**<br>**Mitsubishi Electric Europe B.V.**<br>25, Boulevard des Bouvets<br>F-92741 Nanterre Cedex<br>Phone: +33 (0)1 / 55 68 55 68|**Ireland**<br>**Mitsubishi Electric Europe B.V.**<br>Westgate Business Park, Ballymount<br>IRL-Dublin 24<br>Phone: +353 (0)1 4198800|**Italy**<br>**Mitsubishi Electric Europe B.V.**<br>Viale Colleoni 7 Palazzo Sirio<br>I-20864 Agrate Brianza (MB)<br>Phone: +39 039 / 60 53 1|**Netherlands**<br>**Mitsubishi Electric Europe B.V.**<br>Nijverheidsweg 23C<br>NL-3641RP Mijdrecht<br>Phone: +31 (0) 297 250 350|**Poland**<br>**Mitsubishi Electric Europe B.V.**<br>ul. Krakowska 50<br>PL-32-083 Balice<br>Phone: +48 (0) 12 347 65 00|
|**i Electric (Russia) LLC**<br>tnikovskaya st.<br>Moscow<br>495 / 721 2070|**Spain**<br>**Mitsubishi Electric Europe B.V.**<br>Carretera de Rubí 76-80 Apdo. 420<br>E-08190 Sant Cugat del Vallés<br>(Barcelona)<br>Phone: +34 (0) 93 / 5653131|**Sweden**<br>**Mitsubishi Electric Europe B.V.**<br>**(Scandinavia)**<br>Hedvig Möllers gata 6<br>SE-223 55 Lund<br>Phone: +46 (0) 8 625 10 00|**Turkey**<br>**Mitsubishi Electric Turkey Elektrik**<br>**Ürünleri A.Ş.**<br>Şerifali Mahallesi Nutuk Sokak No:5<br>TR-34775 Ümraniye-İSTANBUL<br>Phone: +90 (216) 969 25 00|**UK**<br>**Mitsubishi Electric Europe B.V.**<br>Travellers Lane<br>UK-Hatfield, Herts. AL10 8XB<br>Phone: +44 (0)1707 / 28 87 80|**UAE**<br>**Mitsubishi Electric Europe B.V.**<br>Dubai Silicon Oasis<br>United Arab Emirates - Dubai<br>Phone: +971 4 3724716||
## **Representatives**
|**sentatives**|||||||
|---|---|---|---|---|---|---|
|aße 89<br>en<br>(0)2252 / 85 55 20|**Belarus**<br>**OOO TECHNIKON**<br>Prospect Nezavisimosti 177-9<br>BY-220125 Minsk<br>Phone: +375 (0)17 / 393 1177|**Bosnia and Herzegovina**<br>**INEA RBT d.o.o.**<br>Stegne 11<br>SI-1000 Ljubljana<br>Phone: +386 (0)1/ 513 8116|**Bulgaria**<br>**AKHNATON**<br>4, Andrei Ljapchev Blvd., PO Box 21<br>BG-1756 Sofia<br>Phone: +359 (0)2 / 817 6000|**Croatia**<br>**INEA CR**<br>Losinjska 4 a<br>HR-10000 Zagreb<br>Phone: +385 (0)1 / 36 940 - 01/ -02/ -03|**Czech Republic**<br>**AutoCont C.S. S.R.O.**<br>Kafkova 1853/3<br>CZ-702 00 Ostrava 2<br>Phone: +420 595 691 150|**Denmark**<br>**HANS FØLSGAARD A/S**<br>Theilgaards Torv 1<br>DK-4600 Køge<br>Phone: +45 4320 8600|
|**OÜ**<br>160i<br>Tallinn<br>2 6518 140|**Finland**<br>**UTU Automation Oy**<br>Peltotie 37<br>FIN-28400 Ulvila<br>Phone: +358 (0)207 / 463 500|**Greece**<br>**UTECO A.B.E.E.**<br>5, Mavrogenous Str.<br>GR-18542 Piraeus<br>Phone: +30 (0)211 / 1206-900|**Hungary**<br>**MELTRADE Kft.**<br>Fertő utca 14.<br>HU-1107 Budapest<br>Phone: +36 (0)1 / 431-9726|**Kazakhstan**<br>**TOO Kazpromavtomatika**<br>Ul. Zhambyla 28<br>KAZ-100017 Karaganda<br>Phone: +7 7212 / 50 10 00|**Latvia**<br>**OAK Integrator Products SIA**<br>Ritausmas iela 23<br>LV-1058 Riga<br>Phone: +371 67842280|**Lithuania**<br>**Automatikos Centras, UAB**<br>Neries krantiné 14A-101<br>LT-48397 Kaunas<br>Phone: +370 37 262707|
|**E Ltd.**<br>ill<br>a PLA 1702<br>6 (0)21 / 697 816|**Moldova**<br>**INTEHSIS SRL**<br>bld. Traian 23/1<br>MD-2060 Kishinev<br>Phone: +373 (0)22 / 66 4242|**Portugal**<br>**Fonseca S.A.**<br>R. João Francisco do Casal 87/89<br>PT-3801-997 Aveiro, Esgueira<br>Phone: +351 (0)234 / 303 900|**Romania**<br>**Sirius Trading & Services**<br>Aleea Lacul Morii Nr. 3<br>RO-060841 Bucuresti, Sector 6<br>Phone: +40 (0)21 / 430 40 06|**Serbia**<br>**INEA SR d.o.o.**<br>Ul. Karadjordjeva 12/217<br>SER-11300 Smederevo<br>Phone: +386 (026) 461 54 01|**Slovakia**<br>**SIMAP SK**<br>Dolné Pažite 603/97<br>SK-911 06 Trenčín<br>Phone: +421 (0)32 743 04 72|**Slovenia**<br>**INEA RBT d.o.o.**<br>Stegne 11<br>SI-1000 Ljubljana<br>Phone: +386 (0)1 / 513 8116|
|**and**<br>**AG**<br>5<br>übendorf<br>(0)44 / 802 28 80|**Ukraine**<br>**CSC- AUTOMATION Ltd.**<br>4 B, Yevhenа Sverstyuka Str.<br>UA-02002 Kiev<br>Phone: +380 (0)44 / 494 33 44|**Israel**<br>**SHERF MOTION TECHN. Ltd.**<br>Rehov Hamerkava 19<br>IL-58851 Holon<br>Phone: +972 (0)3 / 559 54 62<br>**Lebanon**<br>**CEG LIBAN**<br>Cebaco Center/Block A<br>Autostrade DORA<br>Lebanon-Beirut<br>Phone: +961 (0)1 / 240 445<br>**South Africa**<br>**ADROIT TECHNOLOGIES**<br>20 Waterford Office Park 189<br>Witkoppen Road<br>ZA-Fourways<br>Phone: + 27 (0)11 / 658 8100|||||
|**ADON Ltd.**<br>nut Street<br>etanya<br>2 (0)9 / 863 39 80|**Israel**<br>**ILAN & GAVISH Ltd.**<br>24 Shenkar St., Kiryat Arie<br>IL-49001 Petah-Tikva<br>Phone: +972 (0)3 / 922 18 24|**Israel**<br>**SHERF MOTION TECHN. Ltd.**<br>Rehov Hamerkava 19<br>IL-58851 Holon<br>Phone: +972 (0)3 / 559 54 62|**Lebanon**<br>**CEG LIBAN**<br>Cebaco Center/Block A<br>Autostrade DORA<br>Lebanon-Beirut<br>Phone: +961 (0)1 / 240 445|**South Africa**<br>**ADROIT TECHNOLOGIES**<br>20 Waterford Office Park 189<br>Witkoppen Road<br>ZA-Fourways<br>Phone: + 27 (0)11 / 658 8100|||
## **Version check**
## **Mitsubishi Electric Europe B.V.**
FA - European Business Group Mitsubishi-Electric-Platz 1 D-40882 Ratingen Germany Tel.: +49(0)2102-4860 Fax: +49(0)2102-4861120 info@mitsubishi-automation.com https://eu3a.mitsubishielectric.com Art. no. 167840-H Specifications subject to change. All trademarks and copyrights acknowledged.
Printed August 2017
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →