Image not available
Illustrative purposes only
SSR320DIN-DC22
SSR, DIN RAIL MOUNT, 60VDC, 32VDC, 20A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SCHNEIDER ELECTRIC/LEGACY RELAY
- Product type: Solid State Relays
- Load Current: 20A
- Relay Mounting: DIN Rail
- Switching Mode: DC Switch
- Relay Terminals: Screw
- Control Voltage Max: 32VDC
- Control Voltage Min: 4VDC
- Contact Configuration: SPST-NO
- Operating Voltage Max: 60VDC
- Operating Voltage Min: 0VDC
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 207.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product data sheet Characteristics miniature plug-in relay - Zelio RXM - 4 C/O - 24 V AC - 6 A - with LED ## RXM4AB2B7 ## Main ||Main| |---|---| ||Range of product<br>Zelio Relay| ||Series name<br>Miniature| ||Product or component<br>Plug-in relay| ||type| ||Device short name<br>RXM| ||Contacts type and<br>4 C/O| ||composition| ||Contacts operation<br>Standard| ||Control circuit voltage<br>24 V AC| ||[Ithe] conventional<br>6 A at <= 55 °C| ||enclosed thermal| |Complementary<br>[Ui] rated insulation voltage<br>[Uimp] rated impulse withstand voltage<br>Contacts material<br>[Ie] rated operational current<br>Minimum switching current<br>Maximum switching voltage<br>Minimum switching voltage<br>Resistive rated load<br>Maximum switching capacity<br>Minimum switching capacity<br>Operating rate<br>Mechanical durability<br>Electrical durability<br>Average consumption in W<br>Average consumption in VA<br>Drop-out voltage threshold<br>Operating time<br>Average resistance<br>Rated operational voltage limits<br>Protection category<br>Operating position<br>CAD overall width|current<br>Status LED<br>With<br>Control type<br>Pushbutton<br>Coil interference<br>suppression<br>Without<br>Utilisation coefficient<br>20 %<br>Sale per indivisible<br>quantity<br>10<br>250 V conforming to IEC<br>300 V conforming to CSA<br>300 V conforming to UL<br>4 kV conforming to IEC 61000-4-5<br>Silver alloy (Ag/Ni)<br>3 A (AC-1/DC-1) NC conforming to IEC<br>6 A (AC-1/DC-1) NO conforming to IEC<br>8 A (AC-1/DC-1) conforming to UL<br>10 mA<br>250 V AC/DC<br>17 V<br>6 A at 250 V AC<br>6 A at 28 V DC<br>1500 VA, AC circuit<br>168 W, DC circuit<br>170 mW<br><= 20 cyc/mn (under load)<br><= 300 cyc/mn (no-load)<br>10000000 cycles<br>100000 cycles for resistive load<br>0.9 W, DC circuit<br>1.2, AC circuit<br>>= 0.1 Uc (DC<br>>= 0.15 Uc (AC<br>20 ms between coil de-energisation and making of the Off-delay contact (AC/DC)<br>20 ms between coil energisation and making of the On-delay contact (AC/DC)<br>180 Ohm, AC circuit at 20 °C +/- 15 %<br>19.2...26.4 V AC<br>RT I<br>Any position<br>21 mm| ## Complementary 7/9/2011 1 CAD overall height 27 mm CAD overall depth 55 mm Product weight 0.037 kg |Environment|| |---|---| |Dielectric strength|1500 V AC (between contacts)| ||1550 V AC (between coil and contact)| ||1550 V AC (between poles)| |Product certifications|CSA| ||UL| |Standards|CSA C22-2 No 14| ||EN/IEC 61810-1 (iss. 2)| ||UL 508| |Ambient air temperature for storage|-40...85 °C| |Ambient air temperature for operation|-40...55 °C| |Vibration resistance|3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on opening) conforming to EN/IEC| ||60068-2-27| ||5 gn (f = 10...150 Hz), amplitude +/- 1 mm (on closing) conforming to EN/IEC| ||60068-2-27| |IP degree of protection|IP40 conforming to EN/IEC 60529| |Shock resistance|15 gn on closing conforming to EN/IEC 60068-2-27| ||15 gn on opening conforming to EN/IEC 60068-2-27| |RoHS EUR status|Compliant| |RoHS EUR conformity date|0801| 2 Product data sheet Dimensions Drawings ## RXM4AB2B7 ## Miniature Relay ## Dimensions Pin Side View 3 Product data sheet Connections and Schema ## RXM4AB2B7 Miniature Relay ## Wiring Diagram Symbols shown in blue correspond to Nema marking. 4 Product data sheet Performance Curves ## RXM4AB2B7 ## RXM Miniature Relays ## Electrical Durability of Contacts Durability (inductive load) = durability (resistive load) x reduction coefficient. Resistive AC load - X Switching capacity (kVA) - Y Durability (Number of operating cycles) A RXM2AB••• B RXM3AB••• C RXM4ΑΒ••• D RXM4GΒ••• Reduction coefficient for inductive AC load (depending on power factor cos ϕ) Y Reduction coefficient (A) Maximum switching capacity on resistive DC load X Voltage DC Y Current DC A RXM2AB••• B RXM3AB••• C RXM4ΑΒ••• D RXM4GΒ••• 5
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →