Image not available
Illustrative purposes only
SF541310
Solid State Relay, 10 A, 280 Vrms, Panel Mount, Quick Connect, Zero Crossing
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CELDUC
- Product type:
- Contact Configuration:-; Load Current:10A; Operating Voltage Max:280Vrms; Relay Mounting:Panel; Relay Terminals:Quick Connect; Switching Mode:Zero Crossing; Operating Voltage Min:12Vrms; Control Voltage
- SVHC: Lead (27-Jun-2024)
- Load Current: 10A
- Product Range: SF5 Series
- Relay Mounting: Panel Mount
- Switching Mode: Zero Crossing
- Relay Terminals: Quick Connect
- Control Voltage Max: 30VDC
- Control Voltage Min: 4VDC
- Contact Configuration: -
- Operating Voltage Max: 280Vrms
- Operating Voltage Min: 12Vrms
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 38.02 € |
| Current stock | 25+ |
| Lead time | 30 days |
~~S/MON/SF541310/D/07/04/2020~~ page 1/3 F/GB ## _**VERY SMALL POWER SOLID STATE RELAY RELAIS STATIQUE DE PUISSANCE MINIATURE**_ 4-30VDC control **12(*)/280VAC** output Zero cross / Synchrone Synchrone Flat tab connections / SF5 is a miniature zero cross solid state relay for medium power applications. Zero cross / Synchrone Synchrone It is built with high performance components with very high immunity making this SoFlat tab connections / lid-State relay suitable for all kind of loads (e.g. Heaters, electric valves, small mo- _Cosses Fastons_ tors,...). His very small size allowed to place it as an interface in all interfacing configurations _Le SF5 est un relais statique miniature synchrone de moyenne puissance. Il est fabriqué avec des composants à haute immunité permettant le pilotage de tout type de charges (résistances de chauffage, électrovannes, petits moteurs,...). Son volume extrêmement modeste permet une intégration dans toutes les combinaisons d'interfaçage._ Dimensions **File 10A** 48x08 El mA \1 **E69913** US Ke **10A (*) With heatsink / avec dissipateur 240VAC** Typical Application / _Application typique_ : Heaters / _Chauffage_ : 2KWatts/230VAC ==> AC-51 = 8.7A 30 25,7 Schéma équivalent/ _Equivalent circuit_ == 1 eo ANH NS 3+ R =|“ C—~] Zero Cross 3+ 1B as 4- 2 ## Control characteristics (at 20°C) / _Caractéristiques de commande (à 20°C)_ |||||DC|||| |---|---|---|---|---|---|---|---| ||Parameters /_Paramètres_|Symbol|Min|Nom||Max|Unit| |Control voltage /_Tension de commande_<br>Control current /_Courant de commande_ (@ Uc )<br>Release voltage /_Tension de relachemen_t<br>Input internal resistor /_Résistance interne_(fig.1)<br>Uc<br>Ic<br>4<br>3<br>Uc off<br>Rc<br>1<br>1000<br>Reverse voltage /_Tension inverse_<br>Input-output characteristics(at 20°C)/_Caractéristiques d'entrée-sortie(à 20°C_<br>Input-output isolation /_Isolement entrée-sortie_ @500m<br>Output-case isolation /_Isolement sortie-semelle_ @500m<br>Urv<br>Ui<br>Ui<br>Rated impulse voltage /_Tension assignée Isolement_<br>Uimp<br>30<br>4000<br>2500<br>4000<br>~~————~~|||||30<br>29<br>_à 20°C)_||V<br>mA<br>V<br>Ω<br>V<br>Vrms<br>Vrms<br>V| fig. 1 :Control characteristic / _Caractéristique d'entrée_ ## Caractéristiques générales / _General characteristics_ |Parameters /_Paramètres_|Conditions|Symbol|Typ.|Unit| |---|---|---|---|---| |Weight /_Poids_|||90|g| |Storage temperature range /_Plage de température de stockage_|||-40 / +100|°C| |Operatingtemperature range /_Plage de température de fonctionnement_|||-40 / +100|°C| ## _**Proud to serve you**_ All technical characteristics are subject to change without previous notice. _Caractéristiques sujettes à modifications sans préavis._ ~~S/MON/SF541310/D/07/04/2020~~ page 2/3 F/GB Output characteristics (at 20°C) / _Caractéristiques de sortie(à 20°C) /_ **==> picture [501 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||||| |---|---|---|---|---|---|---|---|---|---|---| |GO|Parameters /|Paramètres|Conditions|Symbol|Typ.|Unit| |GO|Load voltage /|Tension de charge|Ue|230|V rms| |CO|Operating voltage range /|Plage tension de fonctionnement|Uemin-max|12-280|V rms| |CC|Peak breakdown voltage /|Tension crête d'avalanche|Up|600|V| |GO|Synchronizing level /|Niveau de synchonisation|Usync|12|V| |GO|Latching voltage /|Tension d'amorçage|Ie nom|Ua|8|V| |GO|Nominal load current (heaters) /|Courant de charge nominal (chauffage)|( see Fig. 2 )|Ie AC-51|12|A rms| |GO|Nominal load current (motors) /|Courant de charge nominal (moteur)|VDR protection required|Ie AC-53a|2.5|A rms| |CO|Non repetitive overload current /|Courant de surcharge non répétitif|1 cycle 50/60Hz (Fig3)|Itsm|120/126|A| |CC|On state voltage drop /|Chute tension directe|@ Ie nom|Vd|1.55|V| |GO|Off state leakage current /|Courant de fuite état bloqué|@Ue, 50Hz|Ilk|<3|mA| |GO|Minimum load current /|Courant de charge minimum|@50Hz|Ie min|5|mA| |GO|Turn ON time /|Temps de fermeture|Uc nom DC ,f=50Hz|ton max|10|ms| |GO|Turn OFF time /|Temps d'ouverture|Uc nom DC ,f=50Hz|toff max|10|ms| |CO|Operating frequency mains range /|Plage de fréquence réseau|f|0,1-800|Hz| |CC|Off state dv/dt /|dv/dt état bloqué|dv/dt|500|V/µs| |GO|Maximum non repetitive di/dt /|dI/dt maximum non répétitif|di/dt|50|A/µs| |GO|Fusing energy /|Energie de fusion|@10ms|I|[2]|t|78|A|[2]|s| |OO|EMC conducted immunity level /|Test CEM d'immunité conduite|EN61000-4-4 (burst)|2kV criterion B| |OO|EMC Conducted immunity level /|Test CEM d'immunité conduite|EN61000-4-5(schocks)|2kV crit.A with external VDR| |DO|Compliance /|Conformité|EN60947-4-3| **----- End of picture text -----**<br> Fig. 2 Thermal curves and heatsink choice / _Courbes thermiques & Choix dissipateur thermique /_ ® ~~**www.celduc.com**~~ **r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE** ~~e~~ euc ~~—____~~ **Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** S/MON/SF541310/D/07/04/2020 fig 3 : Overload currents / _Courants de surcharges_ page 3/3 F/GB - 1 - Non repetitive Itsm is given without voltage reapplied . This curve is used to define the pro tection (fuses). 2 - Repetitive Itsm is given for inrush current with initial Tj = 70°C. In normal operation, this curve musn't be exceeded. Caution, frequent over load currents will decrease the life expectancy of the SSR. - 1 - _Itsm non répétitif sans tension réappliquée est donné pour la détermination des protections. 2 -Itsm répétitif est donné pour des surcharges de courant (Tj initiale=70°C). Attention : la répétition de ces surcharges de courant diminue la durée de vie du relais._ **→ Warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in conjunction with an adapted circuit breaker with insulation feature or a similar device in order to ensure a reliable insulation in the event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). It is important that the solid state relay is subject to correct installation, maintenance and use conforming to its intended regulations and standards, to the supplier's instructions and to accepted rules of art.** _**→ Attention ! les relais à semi-conducteurs ne procurent pas d'isolation galvanique entre le réseau et la charge. Ils doivent être utilisés associés à un disjoncteur avec propriété de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la ligne dans l'hypothèse d'une défaillance et pour tous les cas où le relais doit être isolé du réseau (maintenance; non utilisation sur une longue durée...).**_ _**Sous réserve d'installation, d'entretien et d'utilisation conformes à sa destination, à la réglementation, aux normes en vigueur, aux instructions du constructeur et aux règles de l'art.**_ ## Protection / _Protection_ : - −> To protect a SSR against a short-circuit of the load , use a fuse with a I[2] t value = 1/2 I[2] t value specified page 2. A test has been made with FERRAZ SCHAWMUT fuses . It is possible to protect SSR by MCB ( miniature circuit breaker) by using a SSR with high I[2] t value (5000A[2] s minimum). See our application note about coordination of protection type "1" or type "2" according EN60947-4-1. - -> _La protection d'un relais statique contre les court-circuits de la charge peut être faite par fusibles rapides avec des I[2] t = 1/2 I[2] t du relais. Un test en laboratoire a été effectué sur les fusibles de marque FERRAZ SCHAWMUT. Une protection par MCB ( disjoncteurs modulaires miniatures) est aussi possible en utilisant des relais avec I[2] t >5000A[2] s. Voir notre note application concernant la coordination de protection type "1" ou type "2"_ ## EMC / _CEM_ : - **−> Immunity:** For the products, we give in our data-sheets immunity level according to the main standards: IEC/EN61000-4-4 & IEC/EN61000-4-5. But we are also in conformity with other standards IEC/EN61000-4-2, IEC/EN61000-4-6,... in compliance with IEC/EN60947-4-3. **−> Emission: celduc[®] relais** SSRs are mainly designed in compliance with standards for class A equipment (Industry). Use of the products in domestic environments may cause radio interference. In that case the user may be required to employ additionnal devices to reduce EMC noise. SSRs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. Because the other equipment or the interconnections may not be under the control of **celduc[®] relais** , it shall be the responsability of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and regulations applicable at the system level. Consult **celduc[® ] relais** for advices. Pre-testing can be performed in our laboratory. - _**-> Immunité :** Nous spécifions dans nos notices le niveau d'immunité de nos produits selon les normes essentielles pour ce type de produit, c'est à dire IEC/ EN61000-4-4 & IEC/ EN61000-4-5. Mais nous respectons aussi les autres normes CEM IEC/ EN61000-4-2 ; IEC/ EN61000-4-6; .... en conformité avec la norme IEC60947-4-3._ - _**−> Emission :** Nos relais statiques sont principalement conçus et conformes pour la classe d'appareils A (Industrie)._ _L'utilisation du produit dans des environnements domestiques peut amener l'utilisateur à employer des moyens d'atténuation supplémentaires. En effet, les relais statiques sont des dispositifs complexes qui doivent être interconnectés avec d'autres materiels (charges, cables, etc) pour former un système. Etant donné que les autres materiels ou interconnexions ne sont pas de la responsabilité de_ _**celduc[®] relais** , il est de la responsabilité du réalisateur du système de s'assurer que les systèmes contenant des relais statiques satisfont aux prescriptions de toutes les règles et règlements applicables au niveau des systèmes._ _Consulter_ _**celduc[® ] relais** qui peut vous conseiller ou réaliser des essais dans son laboratoire sur votre application._ ® ~~**www.celduc.com**~~ sam ~~—__—_—_______~~ **r e l a i s** celduc ~~——_____~~ Qualité **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →