RV8H-L-AD110-HD
INTERFACE RELAY, SPDT, 125V, 6A/DIN RAIL
- Manufacturer: IDEC
- Product type: Power Relays
- Contact Configuration:SPDT; Coil Voltage:125V; Contact Current:6A; Product Range:RV8H Series; Relay Mounting:DIN Rail; Coil Type:Non Latching; Contact Voltage 56AJ0578
- Coil Type: Non Latching
- Coil Voltage: 125V
- Product Range: RV8H Series
- Relay Mounting: DIN Rail
- Coil Resistance: 32.9kohm
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: Silver Nickel
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 30.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
Interface Relays Screw and spring clamp terminals ## RV8H **==> picture [211 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Marking plate can be installed on the release lever<br>=<br>Marking plate<br>can be installed<br>on the release<br>lever.<br>**----- End of picture text -----**<br> **==> picture [132 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Only 70mm from the DIN rail<br>**----- End of picture text -----**<br> Ultra-slim interface relays suitable for high density mounting **==> picture [160 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> • See website for details on approvals and standards.<br>**----- End of picture text -----**<br> **==> picture [203 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> Only70mm<br>ie from the DIN rail<br>Shortest in its<br>class<br>Slim Width<br>6mm<br>Easy wiring, simple maintenance<br>LED indicator.<br>Release lever for easy locking and removal of relays.<br>**----- End of picture text -----**<br> ## 6A contact capacity in the slim housing Gold-clad contacts for high contact reliability For more information, visit http://asia.idec.com CO? H-027 RV8H Interface Relays ## Space-saving 6mm width suitable for high density mounting. APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors ## Interface Relays |Contact<br>Arrangement|Coil Voltage|Part No.|Part No.| |---|---|---|---| |||Screw Terminal|Spring Clamp Terminal| |||ii|a| |SPDT|6V DC|RV8H-L-D6|RV8H-S-D6| ||9V DC|RV8H-L-D9|RV8H-S-D9| ||12V DC|RV8H-L-D12|RV8H-S-D12| ||18V DC|RV8H-L-D18|RV8H-S-D18| ||24V DC|RV8H-L-D24|RV8H-S-D24| ||12V AC/DC|RV8H-L-AD12|RV8H-S-AD12| ||18V AC/DC|RV8H-L-AD18|RV8H-S-AD18| ||24V AC/DC|RV8H-L-AD24|RV8H-S-AD24| ||48V AC/DC|RV8H-L-AD48|RV8H-S-AD48| ||60V AC/DC|RV8H-L-AD60|RV8H-S-AD60| ||110-125V AC/DC|RV8H-L-AD110|RV8H-S-AD110| ||220-240V AC/DC|RV8H-L-AD220|RV8H-S-AD220| Download catalogs and CAD from http://asia.idec.com/downloads H-028 RV8H Interface Relays ## Accessories ## Relay / Socket Package Quantity: 1 |APEM<br>Switches &<br>Pilot Lights<br>Control Boxes<br>Emergency<br>StopSwitches<br>Enabling<br>Switches<br>Safety Products<br>Explosion Proof<br>Terminal Blocks<br>Relays & Sockets<br>Circuit<br>Protectors<br>Power Supplies<br>LED Illumination<br>Relays & Sockets<br>Screw Terminal<br>Spring Clamp Terminal<br>Interface Relay<br>Complete Part No.<br>Applicable Socket<br>Part No.<br>Applicable Relay<br>Part No.<br>Interface Relay<br>Complete Part No.<br>Applicable Socket<br>Part No.<br>Applicable Relay<br>Part No.<br>RV8H-L-D6<br>SV1H-07L-5<br>RV1H-G-D5<br>RV8H-S-D6<br>SV1H-07LS-5<br>RV1H-G-D5<br>RV8H-L-D9<br>RV1H-G-D9<br>RV8H-S-D9<br>RV1H-G-D9<br>RV8H-L-D12<br>RV1H-G-D12<br>RV8H-S-D12<br>RV1H-G-D12<br>RV8H-L-D18<br>RV1H-G-D18<br>RV8H-S-D18<br>RV1H-G-D18<br>RV8H-L-D24<br>RV1H-G-D24<br>RV8H-S-D24<br>RV1H-G-D24<br>RV8H-L-AD12<br>SV1H-07L-1<br>RV1H-G-D12<br>RV8H-S-AD12<br>SV1H-07LS-1<br>RV1H-G-D12<br>RV8H-L-AD18<br>RV1H-G-D18<br>RV8H-S-AD18<br>RV1H-G-D18<br>RV8H-L-AD24<br>RV1H-G-D24<br>RV8H-S-AD24<br>RV1H-G-D24<br>RV8H-L-AD48<br>SV1H-07L-2<br>RV1H-G-D48<br>RV8H-S-AD48<br>SV1H-07LS-2<br>RV1H-G-D48<br>RV8H-L-AD60<br>RV1H-G-D60<br>RV8H-S-AD60<br>RV1H-G-D60<br>RV8H-L-AD110<br>SV1H-07L-3<br>RV1H-G-D60<br>RV8H-S-AD110<br>SV1H-07LS-3<br>RV1H-G-D60<br>~~OO~~<br>~~| gf _~~<br>~~oY~~<br>~~ee~~<br>~~es~~<br>~~ee ee~~<br>~~oT~~<br>~~rr~~<br>~~ee ee~~<br>~~od~~<br>~~ee~~<br>~~ee ee~~<br>~~Co~~<br>~~oY~~<br>~~|~~<br>~~oo~~<br>~~a —~~<br>~~—po~~<br>~~ee ee~~<br>~~Cd~~<br>~~a~~<br>~~rr~~<br>~~es ee~~<br>~~Cd~~<br>~~a~~<br>~~a~~<br>~~0~~| |---| |Controllers<br>Operator<br>RV8H-L-AD220<br>SV1H-07L-4<br>RV1H-G-D60<br>RV8H-S-AD220<br>SV1H-07LS-4<br>RV1H-G-D60<br>~~a~~<br>~~a~~| |Interfaces| |Sensors| |AUTO-ID<br>Specifications<br>Part No.<br>RV8H-L (Screw Terminal)<br>RV8H-S (Spring Clamp Terminal)<br>~~a a~~| |Number of Poles<br>1-pole<br>~~(a~~| |Relays<br>Sockets<br>DIN Rail<br>Products<br>RJ<br>RU<br>RV8H<br>RL<br>Contact Configuration<br>SPDT<br>Contact Material<br>Silver alloy (gold-plated)<br>Degree of Protection<br>Relay: IP67, Socket: IP20 (IEC 60529)<br>Contact Resistance (initial value)<br>100mΩ maximum<br>Operate Time<br>15ms maximum<br>Release Time<br>20ms maximum<br>Insulation Resistance<br>1,000MΩ minimum (500V DC megger)<br>Dielectric<br>Strength<br>Between contact and coil<br>4,000V AC, 1 minute<br>Between contacts of the same pole<br>1,000V AC, 1 minute<br>Vibration<br>Resistance<br>Operation extremes<br>10 to 55 Hz, amplitude 0.5mm (NO contact), 0.2mm (NC contact)<br>Damage Limits<br>10 to 55 Hz, amplitude 0.5mm (NO contact), 0.2mm (NC contact)<br>Shock<br>Resistance<br>Operation extremes<br>49 m/s2(NO contact), 29.4 m/s2(NC contact)<br>Damage Limits<br>980 m/s2<br>~~”™~tCOL~~<br>~~I ee~~<br>~~a ee~~<br>~~Oa~~<br>~~eeLO~~<br>~~ee~~<br>~~——a~~<br>~~ee~~<br>~~**A**~~<br>~~ddee~~<br>~~ee~~<br>~~a~~<br>~~eC~~| |Electrical Life (rated load)<br>30,000 operations minimum (NO contact), 10,000 operations minimum (NC contact)<br>(250V AC/30V DC, 6A resistive load, operation frequency 1,800 operations per hour)| |Mechanical Life (no load)<br>10 million operations minimum (operation frequency 18,000 operations/hour)<br>Operating Temperature<br>RV8H-*-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60: –40 to +70°C (no freezing) RV8H-*-AD110,<br>AD220: –40 to +55°C (no freezing)<br>~~Oa~~| |Operating Humidity<br>5 to 85% RH (no condensation)<br>~~a~~| |Storage Temperature<br>–40 to +85°C (no freezing)<br>~~a~~| |Storage Humidity<br>5 to 85% RH (no condensation)<br>~~(a~~| |Weight (approx.)<br>30g<br>26g<br>~~a~~| For more information, visit http://asia.idec.com H-029 RV8H Interface Relays ## Approval Ratings UL and c-UL Ratings VDE Ratings (RV1H relay only) Voltage Resistive Inductive Voltage Resistive 250V AC 6A B300/R300 250V AC 6A 30V DC 6A (pilot duty) 30V DC 6A ~~—~~ Contact Ratings Allowable Contact Power Rated Load Allowable Allowable Minimum APEM Resistive Load Inductive Load Voltage Resistive Load Inductive Load Switching Current Switching Voltage Applicable Load Switches & Pilot Lights 1,500VA AC B300: AC 360 VA 250V AC 6A B300: 240V AC 1.5A 400V AC 6V DC, 10 mA Control Boxes R300: DC 28 VA R300: 250V DC 0.11A 6A 180W DC (pilot duty) 30V DC 6A (pilot duty) 125V DC (reference value) Emergency Stop Switches Enabling Coil Ratings Switches Operating Characteristics Safety Products Rated Coil Impedance (Ω) (against rated values at 23°C) Coil Voltage Current (mA) Resistance ( Ω ) ±15% Power Explosion Proof Rated Voltage (V) Code ±15% (at 23°C) (*1) ±15% (at 23°C) (*1) (at 23°C) (*1) Maximum Allowable Minimum Pickup Dropout Voltage Consumption Terminal Blocks Voltage Voltage ~~cor~~ Relays & Sockets ~~et~~ 6V DC D6 35 170 0.21 Circuit 9V DC D9 18.6 485 Protectors DC 12V DC D12 14.6 820 0.2 Power Supplies 18V DC D18 11.6 1,550 ~~==>~~ 24V DC D24 ~~**—**~~ 10.6 ~~—~~ 2,270 ~~| eee~~ 0.25 LED Illumination ~~—~~ 12V AC/DC AD12 15.5 800 ~~i~~ 755 110% 90% 7% ~~_=~~ 0.2 Controllers 18V AC/DC AD18 13.3 1,345 1,365 maximum minimum 0.25 Operator ~~———~~ 24V AC/DC AD24 13.7 1,790 1,730 ~~—~~ 0.33 Interfaces AC/DC 48V AC/DC AD48 4.0 12,230 11,880 0.2 Sensors 60V AC/DC AD60 3.4 17,910 17,600 110-125V AC/DC AD110 3.4-3.9 32,450-32,900 31,790-31,890 0.5 AUTO-ID ~~(=====~~ 220-240V AC/DC AD220 3.3-3.6 65,940-68,570 65,670-66,070 ~~_~~ 0.85 ~~es |~~ *1) D12 and below: ±10% Accessories Relays Shape Material Part No. Package Quantity Note (dimensions in mm.) Sockets Blank Marking Plate DIN Rail Products PBT plastic (white) SV9Z-PW10 1 No marking ~~FLL~~ Jumper Specify a color code in place of * in the Part No. RJ Rated current: 6A (*2) B: black Brass (nickel-plated) with polyamide sheath SV9Z-J20 * 10 W: gray RU S: blue Approx. 6g Can be cut to required length. RV8H No. of points: 20 ~~sem~~ RL Used for adjusting spacing between sockets DIN Rail Spacer Polyamide (gray) SV9Z-SA2W 1 and to prevent the ends of jumpers from exposing. ~~a a~~ Aluminum, approx. 200g BAA1000PN10 1m long DIN Rail (*3) 10 35mm wide Steel, approx. 320g BAP1000PN10 ~~pe~~ BNL5PN10 Zinc-plated steel 9 End Clip (*3) 10 Approx. 15g BNL6PN10 9 ~~eo_~~ *2) Ensure that the total current to the jumper does not exceed the rated current. *3) See H-071 for DIN rail products. Download catalogs and CAD from http://asia.idec.com/downloads H-030 RV8H Interface Relays All dimensions in mm. ## Dimensions ## Screw Terminal ## RV8H-L **==> picture [272 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> APEM<br>Switches &<br>Pilot Lights<br>Control Boxes<br>Emergency<br>Stop Switches<br>Enabling<br>Switches<br>Safety Products<br>Explosion Proof<br>Terminal Blocks 35 6.1<br>88<br>Relays & Sockets<br>Circuit<br>Protectors<br>Power Supplies Terminal Arrangement<br>14<br>A1<br>75.6 A2 11 71<br>12<br>**----- End of picture text -----**<br> ## AC/DC **==> picture [237 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> LED Illumination<br>Controllers<br>Operator<br>Interfaces 14<br>NO<br>Sensors A1<br>COIL<br>AUTO-ID<br>11 (13+)<br>COM<br>A2<br>COIL<br>Relays<br>12<br>Sockets NC<br>14<br>A1<br>11<br>A2<br>Circuit<br>12<br>**----- End of picture text -----**<br> Sockets DIN Rail Products RJ ## RV1H Internal Connection (bottom view) **==> picture [201 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> RU<br>RV8H<br>RL A1 A2 12 11 14<br>(13+)<br>**----- End of picture text -----**<br> ## Spring Clamp Terminal RV8H-S **==> picture [220 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> 35 6.1<br>93.4<br>75.6 71<br>**----- End of picture text -----**<br> ## DC **==> picture [189 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>NO<br>A1 (+)<br>COIL<br>11 (13+)<br>COM<br>A2 (–)<br>COIL<br>12<br>NC<br>14<br>A1<br>11<br>A2<br>Circuit<br>12<br>**----- End of picture text -----**<br> ## RV8H Internal Connection **==> picture [250 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> AC/DC DC<br>A1 PROTECTIONAND 14 A1+ PROTECTION 14<br>INDICATION 11(13+) AND<br>A2 CIRCUIT 12 A2− INDICATIONCIRCUIT 11(13+)<br>12<br>**----- End of picture text -----**<br> For more information, visit http://asia.idec.com H-031 RV8H Interface Relays ## DIN Rail Spacer SV9Z-SA2W ## Marking Plate SV9Z-PW10 **==> picture [221 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> 35<br>96.7 2<br>66.8<br>71.4<br>**----- End of picture text -----**<br> **==> picture [214 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> 3 Cut<br>1 6<br>86.5<br>16.5<br>10.5<br>**----- End of picture text -----**<br> ## Jumper ## SV9Z-J20 * PN10 **==> picture [252 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> 115.9<br>6.1<br>120 2.8<br>6 12.3<br>**----- End of picture text -----**<br> ## Installing a marking plate **==> picture [136 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> Marking Plate<br>RV8H-L- � Insert<br>**----- End of picture text -----**<br> ## Electrical Life Curve ## Resistive Load ## Inductive Load **==> picture [283 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 50 50<br>10 10<br>250V AC resistive load (NC) 250V AC inductive load (NC)<br>30V DC resistive load (NC) 30V DC inductive load (NC)<br>250V AC resistive load (NO) 250V AC inductive load (NO)<br>30V DC resistive load (NO) 30V DC inductive load (NO)<br>1 1<br>0.1 0.1<br>0.1 0.5 1 3 6 10 0.1 0.5 1 3 6 10<br>Load Current (A) Load Current (A) AC: COS=0.4<br>DC: L/R=7ms<br>Life (× 10,000 operations) Life (× 10,000 operations)<br>**----- End of picture text -----**<br> APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID Relays Sockets DIN Rail Products RJ RU RV8H RL ## Maximum Switching Current ## AC ## DC **==> picture [270 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 5 AC Resistive Load 5<br>2 2<br>AC Inductive Load<br>(p. f=0.35)<br>1 1<br>0.5 0.5 DC Resistive Load<br>DC Inductive Load<br>0.2 0.2 L/R = 56ms<br>0.1 0.1<br>10 20 30 100 200 300 400 10 20 30 100 200 300 400<br>Load Voltage (V) Load Voltage (V)<br>Load Current (A)<br>Load Current (A)<br>**----- End of picture text -----**<br> Download catalogs and CAD from http://asia.idec.com/downloads H-032 RV8H Interface Relays APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID Relays Sockets DIN Rail Products RJ RU RV8H RL ## Safety Precautions - Turn off power before starting installation, removal, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shocks or fire hazard. - Use proper wires to meet the voltage and current requirements. - Make sure that relay and output equipment are connected completely. Incomplete connection may cause overheat, resulting in fire hazard. - Prevent metal fragments and pieces of wire from dropping inside the sockets. Ingress of such fragments and chips may cause fire, failure, or malfunction. - Apply voltage that is applicable to the relay and socket. Otherwise fire, failure, or malfunction will be caused. - To ensure safety, make sure that all descriptions in the operation instructions are followed strictly. ## Instructions - Use a 15A non-time delay fuse for protection against short-circuit. - When lightening surge may enter the input circuit of types AD12, AD18, and AD24, and when lightening surge and noise may enter the input circuit of types AD48 and AD60 of the following products, use a proper varistor. Otherwise, failure maybe caused. ## RV8H-S - Use the following applicable wires for wiring. 0.5mm[2 ] to 2.5mm[2] or AWG20 to AWG14, CU (copper), Stranded or Solid wire: 1 ## 8 to 9mm **==> picture [144 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Relay Recommended Varistor<br>RV8H-L-AD12<br>**----- End of picture text -----**<br> |Relay|Recommended Varistor| |---|---| |RV8H-L-AD12|| |RV8H-L-AD18|Panasonic ERZV07D390| |RV8H-L-AD24|| |RV8H-L-AD48|Panasonic ERZV14D121| |RV8H-L-AD60|| |RV8H-S-AD12|Panasonic ERZV07D390| |RV8H-S-AD18|| |RV8H-S-AD24|| |RV8H-S-AD48|Panasonic ERZV14D121| |RV8H-S-AD60|| - Observe the maximum ambient temperature shown below. Otherwise, fire, failure, or malfunction will be caused. - 55ºC maximum: RV8H-L-AD110/AD220 - RV8H-S-AD110/AD220 - Strip the wire insulation 8 to 9 mm from the end. Stripping the wire insulation too short may cause the wire to come off. Stripping the wire insulation too long may cause short-circuit with the adjacent socket. Make sure to twist the stranded wire to prevent loosening. - For wiring, use the following applicable screwdriver. (The shape of the applicable screwdriver is based on DIN5264.) **==> picture [75 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> ø2.5<br>ø2.5 2.5<br>7° to 13°<br>**----- End of picture text -----**<br> - Wire insertion positions, screwdriver insertion positions, and the directions of screwdriver tip are shown below. - 70ºC maximum: All other part nos. ## Wiring Instructions Screwdriver Port Direction of Screwdriver Tip Wire Port ## RV8H-L - Use the following applicable wires for wiring. - 2.5m[2] max. or AWG14 max., CU (copper), Stranded or Solid wire : 1 1.5m[2] max. or AWG16 max., CU (copper), Stranded wire : 2 max. ø1.3mm max. or AWG16 max., CU(copper) solid wire : 2 max. - 7 to 8mm - Strip the wire insulation 7 to 8 mm from the end. Stripping the wire insulation too short may cause the wire to come off. Stripping the wire insulation too long may cause short-circuit with the adjacent socket. Make sure to twist the stranded wire to prevent loosening. - In applications using ferrules for stranded wires, choose the ferrule listed in the table. **==> picture [234 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Applicable Wire<br>Part No. Manufacturer<br>mm [2] AWG<br>0.5 20 AI0.5-8WH<br>**----- End of picture text -----**<br> |Applicable Wire|Applicable Wire|Part No.|Manufacturer| |---|---|---|---| |mm2|AWG||| |0.5|20|AI0.5-8WH|| |0.75|18|AI0.75-8GY|Phoenix Contact| |1|18|AI1-8RD|| |0.5|22|TE0.5-8|Nichifu| |0.75|20|TE0.75-8|| |1|18|TE1.0-8|| - For wiring, use the following applicable screwdriver. Phillips screwdriver ø3.5mm max. Flat screwdriver ø 3.5mm max. 0.6mm max. 3.5mm max. Recommended tightening torque: - 0.3 N·m to 0.4 N·m (UL certificated: 0.35 N·m) For more information, visit http://asia.idec.com H-033 RV8H Interface Relays Relays & Sockets LED Illumination Controllers Operator Interfaces Sensors RJ RU RV8H ## Instructions ## Wiring Instructions 1. Insert an applicable screw driver into the square-shaped port as shown, until the screwdriver tip touches the bottom of the spring. **==> picture [33 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Screwdriver<br>**----- End of picture text -----**<br> 2. Push in the screwdriver until it touches the bottom of the port. The wire port is now open, and the screwdriver is held in place. The screwdriver will not come off even if you release your hand. 3. While the screwdriver is retained in the port, insert the wire of ferrule into the round-shaped wire port. Each wire port can accommodate one wire or ferrule. When connecting two wires to one terminal, use the adjoining port of the same terminal. **==> picture [84 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> Screwdriver<br>Wire<br>**----- End of picture text -----**<br> 4. Pull out the screwdriver. The connection is now complete. Note: When using wire with insulation diameter or ø2.0mm or less, do not insert the wire too deep where the insulation inserts into the spring clamp opening. Otherwise conductive failure will be caused. Make sure that the wire insulation is stripped 8 to 9 mm and the wire is inserted to the bottom. **==> picture [125 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Incorrect Correct<br>Wire Port Bottom<br>**----- End of picture text -----**<br> ## Removing the Relay - Open the release lever in the direction of the arrow, and remove the relay. **==> picture [141 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> 90˚<br>Release lever<br>Relay<br>**----- End of picture text -----**<br> - Note 1: The relay may pop out when opening the release lever, resulting in possible damage or loss of the relay. To prevent this, rightly press down the relay using a finger when opening the release lever. - Note 2: Do not open the release lever more than 90º, otherwise the socket will be damaged. ## Installing the Relay - Open the release lever, and insert the relay into the socket until the bottom of relay touches the projection A on the socket. Close the release lever until it is latched. **==> picture [134 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> Installed securely<br>Projection A<br>**----- End of picture text -----**<br> Note: When installing the relay, do not press in using a relay. Make sure to use the release lever, otherwise the projection A will be damaged. ## Installing the Socket - Put the groove on the socket(part B) on the DIN rail, and press the socket towards the DIN rail as shown in the figure. APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Circuit Protectors Power Supplies AUTO-ID Relays Sockets DIN Rail Products **==> picture [18 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> part B<br>**----- End of picture text -----**<br> RL ## Removing the Socket - Insert a small flat screwdriver into the slot (part C) of the socket, and pull out the socket as shown in the figure. **==> picture [36 x 49] intentionally omitted <==** **==> picture [19 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> part C<br>**----- End of picture text -----**<br> - Note: When using the RV8H in cold temperature (0ºC or below), install or remove the socket on the mounting rail carefully so that the socket will not be damaged. Download catalogs and CAD from http://asia.idec.com/downloads H-034
Updated at June 5, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →