Image not available
Illustrative purposes only
RSP-2000-48
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 2.016 kW, 48 VDC, 42 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:2.016kW; Output Voltage - Output 1:48V; Output Current - Output 1:42A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RSP-2000 Series
- No. of Outputs: 1Outputs
- Output Power Max: 2.016kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 42A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 406.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
2000W Power Supply with Single Output ## **RSP - 2000 series** **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [268 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>Parallel & VY cL us L A ) J EAL CB CE<br>■ Certificates<br>* Safety: UL/EN/IEC 60950-1<br>* EMC: EN 55022 / 55024<br>■ Applications<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:RSP-2000-SPEC 2018-11-05_ **RSP - 2000 series** 2000W Power Supply with Single Output Caen ee ee eee ee errr ee ee eee ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|||| |---|---|---|---|---| |**RSP-2000-12**<br>**RSP-2000-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4,5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.4**<br>12V<br>24V<br>100A<br>80A<br>0 ~ 100A<br>0 ~ 80A<br>1200W<br>1920W<br>150mVp-p<br>10.5 ~ 14V<br>200mVp-p<br>21 ~ 28V<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>1500ms, 60ms/230VAC at full load<br>16ms/230VAC at 75% load 10ms/230VAC at full load<br>90 ~ 264VAC 127 ~ 320VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>87%<br>COLD START 50A<br>13A/115VAC 7A/230VAC<br>16A/115VAC 10A/230VAC<br>16A/115VAC 10A/230VAC<br><2mA / 240VAC<br>**RSP-2000-48**<br>48V<br>42A<br>0 ~ 42A<br>2016W<br>300mVp-p<br>42 ~ 56V<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>90.5%<br>92%<br>Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover<br>**OVER TEMPERATURE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 125% rated output power<br>14.7 ~ 17.5V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>29.5 ~ 35V<br>57.6 ~ 67.2V<br>**PROTECTION**<br>**DC OK SIGNAL**<br>**REMOTE SENSE**<br>**REMOTE ON-OFF CONTROL**<br>**AUXILIARY POWER**<br>**CURRENT SHARING**<br>The isolated TTL signal out. Please refer to the Function Manual.<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.<br>By electrical signal or dry contact Power ON:open Power OFF:short. Please refer to the Function Manual.<br>5V @ 0.3A, 12V @ 0.8A<br>Up to 8000W or (3+1) units. Please refer to the Function Manual.<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-35 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL60950-1, TUV EN60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>159K hrs min.<br>Telcordia SR-332 (Bellcore) ; 46.3K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>295*127*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 6)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>1.95Kg; 6pcs/12.7Kg/1.15CUFT<br>**NOTE**<br>℃<br>Please contact MEANWELL for 320~370VDC application.<br>℃<br>℃<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2, BSMI CNS13438<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>-----<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Adjustment of output voltage is allowable to 40 ~ 115% of nominal output voltage. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).||**RSP-2000-12**|**RSP-2000-24**|**RSP-2000-48**| ||**DC VOLTAGE**|12V|24V|48V| ||**RATED CURRENT**|100A|80A|42A| ||**CURRENT RANGE**|0 ~ 100A|0 ~ 80A|0 ~ 42A| ||**RATED POWER**|1200W|1920W|2016W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|200mVp-p|300mVp-p| ||**VOLTAGE ADJ. RANGE**|10.5 ~ 14V|21 ~ 28V|42 ~ 56V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±1.0%|±0.5%|±0.5%| ||**LOAD REGULATION**|±1.0%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1500ms, 60ms/230VAC at full load||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC at 75% load 10ms/230VAC at full load||| ||**VOLTAGE RANGE**<br>**Note.4,5**|90 ~ 264VAC 127 ~ 320VDC||| ||**FREQUENCY RANGE**|47 ~ 63Hz||| ||**POWER FACTOR (Typ.)**|0.97/230VAC at full load||| ||**EFFICIENCY (Typ.)**|87%|90.5%|92%| ||**AC CURRENT (Typ.)**<br>**Note.4**|13A/115VAC 7A/230VAC|16A/115VAC 10A/230VAC|16A/115VAC 10A/230VAC| ||**INRUSH CURRENT (Typ.)**|COLD START 50A||| ||**LEAKAGE CURRENT**|<2mA / 240VAC||| ||**OVERLOAD**|Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover<br>105 ~ 125% rated output power||| ||**OVER VOLTAGE**|14.7 ~ 17.5V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>29.5 ~ 35V<br>57.6 ~ 67.2V||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down||| ||**OUTPUT VOLTAGE PROGRAMMABLE(PV)**|Adjustment of output voltage is allowable to 40 ~ 115% of nominal output voltage. Please refer to the Function Manual.||| ||**CURRENT SHARING**|Up to 8000W or (3+1) units. Please refer to the Function Manual.||| ||**AUXILIARY POWER**|5V @ 0.3A, 12V @ 0.8A||| ||**REMOTE ON-OFF CONTROL**|By electrical signal or dry contact Power ON:open Power OFF:short. Please refer to the Function Manual.||| ||**REMOTE SENSE**|Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.||| ||**DC OK SIGNAL**|The isolated TTL signal out. Please refer to the Function Manual.||| ||**WORKING TEMP.**|-35 ~ +70<br>(Refer to "Derating Curve")<br>℃||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes||| ||**SAFETY STANDARDS**|UL60950-1, TUV EN60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**|**Standard**|**Test Level / Note**| |||Conducted|EN55032 (CISPR32) / EN55011 (CISPR11)|Class B| |||Radiated|EN55032 (CISPR32) / EN55011 (CISPR11)|Class A| |||Harmonic Current|EN61000-3-2|-----| |||Voltage Flicker|EN61000-3-3|-----| |||EN55024 , EN61204-3, EN61000-6-2, BSMI CNS13438||| |||**Parameter**|**Standard**|**Test Level / Note**| |||ESD|EN61000-4-2|Level 3, 8KV air ; Level 2, 4KV contact| |||Radiated|EN61000-4-3|Level 3| |||EFT / Burst|EN61000-4-4|Level 3| |||Surge|EN61000-4-5|Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line| |||Conducted|EN61000-4-6|Level 3| |||Magnetic Field|EN61000-4-8|Level 4| |||Voltage Dips and Interruptions|EN61000-4-11|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| |||159K hrs min.<br>Telcordia SR-332 (Bellcore) ; 46.3K hrs min. MIL-HDBK-217F (25<br>)<br>℃||| ||**DIMENSION**|295*127*41mm (L*W*H)||| ||**PACKING**<br>1.95Kg; 6pcs/12.7Kg/1.15CUFT<br>℃<br>Please contact MEANWELL for 320~370VDC application.<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|||| Please contact MEANWELL for 320~370VDC application. ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft). _File Name:RSP-2000-SPEC 2018-11-05_ **RSP - 2000 series** ## 2000W Power Supply with Single Output ## **Block Diagram** **==> picture [491 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 110KHz<br>PWM fosc : 90KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& ORINGFET -V+V<br>-S<br>O.V.P.<br>ORING FET<br>CONTROL<br>PFC PWM DETECTION PV<br>CONTROL CONTROL CIRCUIT<br>TRANSCEIVERS DA/DB<br>DETECTIONCIRCUIT MCU MCU DATA T-Alarm<br>ISOLATION DC-OK<br>O.T.P.<br>AUX FAN RECTIFIERS 12V/0.8A Remote ON-OFF<br>POWER & AUX POWER<br>FILTER 5V/0.3A<br>**----- End of picture text -----**<br> ## **Static Characteristics** **==> picture [205 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>75<br>12V<br>70<br>65 24V,48V<br>50<br>40<br>90 100 115 180 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [172 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> MODEL<br>12V 24V 48V<br>INPUT<br>1200W 1920W 2016W<br>180~264VAC<br>100A 80A 42A<br>1080W 1632W 1713.6W<br>115VAC<br>90A 68A 35.7A<br>1020W 1440W 1512W<br>100VAC<br>85A 60A 31.5A<br>960W 1248W 1310.4W<br>90VAC<br>80A 52A 27.3A<br>**----- End of picture text -----**<br> ## **Derating Curve** ## **Efficiency vs Load (48V Model)** **==> picture [444 x 164] intentionally omitted <==** **----- Start of picture text -----**<br> 94<br>100 92<br>80 90<br>for 180~264VAC<br>88<br>60<br>50 86<br>40<br>84<br>20 82<br>80<br>-35 -25 -10 0 15 30 50 60 70 (HORIZONTAL)<br>10 20 30 40 50 60 70 80 90 100<br>AMBIENT TEMPERATURE ( ℃ ) LOAD<br>◎ The curve above is measured at 230VAC.<br>EFFICIENCY (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:RSP-2000-SPEC 2018-11-05_ **RSP - 2000 series** 2000W Power Supply with Single Output ## **Function Manual** ## **1. Remote Sense** **==> picture [446 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> ※ The Remote Sense compensates voltage drop on the load wiring up to 0.5V<br>PIN2 -S PIN1 +S +V<br>LOAD<br>-V<br>-V +V CN501 Sense lines should be twisted in pairs to minimize noise pick-up.<br>◎ The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.<br>**----- End of picture text -----**<br> **==> picture [461 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> 2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)<br>※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~115% of the nominal voltage by applying<br>EXTERNAL VOLTAGE.<br>PIN2 -S PIN1 +S<br>PIN3 PV<br>EXTERNAL VOLTAGE (DC)<br>-V +V CN501<br>PIN4 GND<br>◎ +S & +V , -S & -V also need to be connected on CN501.<br>Vout<br>100<br>115<br>Non-Linear<br>100 87<br>80 for 12V model 60<br>60 40<br>40<br>20<br>30 for 24V,48V<br>model V<br>20 40 60 80 100 115<br>V<br>0 0.4 1 2 3 4 4.7 5 OUTPUT VOLTAGE (%)<br>EXTERNAL VOLTAGE (DC) ◎ The rated current should change with the<br>Output Voltage Programming accordingly.<br>OUTPUT VOLTAGE(%)<br>OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> ## **3. Remote ON-OFF Control** The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function. **==> picture [431 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> PIN7 Remote ON-OFF<br>Between Remote ON-OFF and +5V-AUX Power Supply Status<br>switch Switch Open ON<br>Switch Short OFF<br>PIN11 +5V-AUX<br>-V +V CN501<br>**----- End of picture text -----**<br> _File Name:RSP-2000-SPEC 2018-11-05_ **RSP - 2000 series** ## 2000W Power Supply with Single Output ## **4.Current Sharing with Remote Sense** RSP-2000 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : - ※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - ※ Difference of output voltages among parallel units should be less than 0.2V. - ※ The total output current must not exceed the value determined by the following equation: - Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 - ※ Under parallel operation, the minimum output load should be greater than 5% of total output load; otherwise, it is likely that only one unit operates whereas other units may enter standby mode or their LED status indicators may not turn on. - ※ When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be fully balanced. - ※ CN502/CN504 Function pin connection **==> picture [465 x 454] intentionally omitted <==** **----- Start of picture text -----**<br> PSU1 PSU2 PSU3 PSU4<br>Parallel<br>CN502 CN504 CN502 CN504 CN502 CN504 CN502 CN504<br>1 unit X V<br>2 unit V V V V<br>3 unit V V V X V V<br>4 unit V V V X V X V V<br>◎V is CN502/CN504 connected to plug pin, X is CN502/CN504 not connected to plug pin.<br>RSP-2000 RSP-2000 RSP-2000 RSP-2000<br>PSU1 PSU2 PSU3 PSU4<br>-V +V CN504 TB1 -V +V CN504 TB1 -V +V CN504 TB1 -V +V CN504 TB1<br>1 5 1 5 1 5 1 5<br>2 6 2 6 2 6 2 6<br>CN502 CN502 CN502 CN502<br>-V +V<br>LOAD<br>Fig 4.1<br>1 3 5 1 3 5 1 3 5 1 3 5<br>DA DB GND DA DB GND DA DB GND DA DB GND<br>DA DB GND DA DB GND DA DB GND DA DB GND<br>2 4 6 2 4 6 2 4 6 2 4 6<br>PSU1 CN502<br>PSU2 CN502 PSU3 CN502 PSU4 CN502<br>If the lines of CN502 are too long, they should<br>be twisted in pairs to avoid the noise.<br>∣ ∣ ∣ ∣ ∣ ∣<br>∣ ∣ ∣ ∣<br>∣ ∣<br>**----- End of picture text -----**<br> - DA,DB and GND are connected mutually in parallel. _File Name:RSP-2000-SPEC 2018-11-05_ **RSP - 2000 series** ## 2000W Power Supply with Single Output **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 952D Unit:mm<br>271<br>6<br>3-M4 L=6<br>1 1<br>295<br>41 21 34.5<br>2-M5<br>-V<br>+V<br>2<br>CN501 SVR Air flow<br>1211 21CN504 CN502 2 34 56 1 2 direction<br>3<br>2<br>1<br>3-M4 L=4<br>TB1<br>2<br>1 1<br>3-M4 L=6<br>6<br>271<br>Chassis of RSP-2000<br>Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque Mounting Surface<br>1 M4 6mm 7~1 K0 gf-cm<br>2 M4 4mm 7~1 K0 gf-cm<br>Mounting Screw<br>※Control Pin No. Assignment (CN501) : HRS DF11-12DP-2DS or equivalent<br>L<br>1 11<br>Mating Housing HRS DF11-12DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>2 12<br>Pin No. Function Description<br>1 +S Positive sensing for remote sense.<br>2 -S Negative sensing for remote sense.<br>3 PV Connection for output voltage programming. (Note.1)<br>4 GND This pin connect to the negative terminal(-V).<br>High (4.5 ~ 5.5V) : When the Vout ≦80%±6%.<br>5 DC-OK Low (0 ~ 0.5V) : When Vout ≧80%±6%.<br>The maximum sourcing current is 10mA and only for output. (Note.2)<br>High (4.5 ~ 5.5V) : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.<br>6 T-ALARM Low (0 ~ 0.5V) : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. The maximum sourcing<br>current is 10mA and only for output. (Note.2)<br>7 Remote The unit can turn the output on and off by electrical signal or dry contact between Remote ON-OFF and +5V-AUX . (Note.2)<br>ON-OFF Short (4.5 ~ 5.5V) : Power OFF ; Open (0 ~ 0.5V) : Power ON ; The maximum input voltage is 5.5V.<br>8,9,10 GND-AUX Auxiliary voltage output GND.<br>The signal return is isolated from the output terminals (+V & -V).<br>11 +5V-AUX Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX .<br>The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON-OFF control.<br>12 +12V-AUX Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX .<br>The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON-OFF control.<br>Note1: Non-isolated signal, referenced to the output terminals (-V).<br>Note2: Isolated signal, referenced to GND-AUX .<br>7.8<br>20.5<br>25.4<br>18.5<br>59<br>127 90<br>10<br>25.4<br>20.5<br>7.8<br>7<br>**----- End of picture text -----**<br> _File Name:RSP-2000-SPEC 2018-11-05_ **RSP - 2000 series** ## 2000W Power Supply with Single Output **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※LED Indicators & Corresponding Signal at Function Pins<br>Function LED Description * Signal Power Supply Output<br>DC-OK GREEN When output voltage ≧ 80% ± 5% of Vo rated. 0 ~ 0.5V ON<br>DC-NG RED When output voltage ≦ 80% ± 5% of Vo rated. 4.5 ~ 5.5V ON<br>T-OK GREEN When the internal temperature (TSW1 & TSW2 short) is within safe limit 0 ~ 0.5V ON<br>T-ALARM RED When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm 4.5 ~ 5.5V OFF<br>*Signal between function pin and "GND-AUX".<br>※Control Pin No. Assignment (CN502) : HRS DF11-6DP-2DSA or equivalent<br>2 1 Mating Housing HRS DF11-6DS or equivalent<br>4 3<br>6 5 Terminal HRS DF11-**SC or equivalent<br>Pin No. Function Description<br>1,2 DA Differential digital signal for parallel control.<br>3,4 DB Differential digital signal for parallel control.<br>5,6 GND These pins connect to the negative terminal (-V).<br>※Control Pin No. Assignment (CN504):<br>Pin No. Function Description<br>Terminal<br>1,2 resistance CN504 is the selector of terminal resistor that is designed for DA/DB signals and parallel control function.<br>※AC Input Terminal Pin No. Assignment<br>Pin No. Assignment Diagram Maximum mounting torque<br>1 AC/N<br>2 AC/L 18Kgf-cm<br>3 FG<br>※DC Output Terminal Pin No. Assignment<br>Assignment Diagram Maximum mounting torque<br>+V, -V 10Kgf-cm<br>Installation Manual<br>Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br> _File Name:RSP-2000-SPEC 2018-11-05_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →