Image not available
Illustrative purposes only
RP1A23D3M1
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (21-Jan-2025)
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 40.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RP1A, RP1B** ## **RP1A, RP1B** ## **1-phase PCB mount solid state relays** ## **Main features** - AC Solid State Relay for PCB mounting - Zero-cross switching or instant-on - Rated operational current: 3, 5 or 5.5 AACrms - Rated operational voltage: up to 480 VACrms - Surface mount technology - Flexible encapsulation for extended life - Control voltage: 3 to 32 VDC / 16 to 32 VAC - Opto-isolation: > 4000 VACrms - Blocking voltage: up to 1000 Vp - Non-repetitive surge current: up to 250 Ap ## **Description** The **RP1** is an SSR series for socket or PCB mounting, providing an ideal interface between logic controls and AC loads. The **RP1** is designed for resistive and inductive loads up to 480 VACrms. Internally this new series enjoys an improved technical design with the introduction of stress-free flexible encapsulation and automated assembly of components. The solid state technology used can withstand peak voltages of 1000 V, making the **RP1** series suitable to drive AC loads such as valve solenoids and small induction motors. Specifications are at a surrounding temperature of 25°C unless otherwise specified. ## **Applications** These relays can be used to switch heaters, motors, lights, valves or solenoids. ## **Main functions** - Zero-cross or instant-on AC switching - Ratings up to 480 VACrms, 5.5 AACrms - 3-32 VDC or 16-32 VAC control voltage **1** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** ## **Order code** ## **RP1** **==> picture [483 x 251] intentionally omitted <==** **----- Start of picture text -----**<br> Enter the code option instead of . Refer to the Selection guide section for valid part numbers.<br>Code Option Description Comments<br>R -<br>Solid State Relay (PCB)<br>P -<br>1 - 1-pole switching<br>A Switching mode: zero-cross switching<br>B Switching mode: instant-on switching<br>23 Rated operational voltage: 230 VACrms<br>40 Rated operational voltage: 400 VACrms<br>48 Rated operational voltage: 480 VACrms<br>4 - 32 VDC for RP1A48..<br>D Control voltage: 3 - 32 VDC<br>4 - 32 VDC for RP1B40.. and RP1B48..<br>A Control voltage: 16 - 32 VAC Only available for 230 V, 5.5 A<br>3 Rated operational current: 3 AACrms<br>5 Rated operational current: 5 AACrms<br>6 Rated operational current: 5.5 AACrms<br>M1 = Mounting on DIN EN adaptor RPM1 Max. 250 V<br>Mx<br>M2 = Mounting on DIN EN adaptor RPM2 Max. 600 V<br>**----- End of picture text -----**<br> ## **Selection guide** **==> picture [483 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Rated operational current<br>Blocking Control<br>operational<br>voltage voltage 3 AACrms 5 AACrms 5.5 AACrms<br>voltage<br>RP1A23D3 RP1A23D5 RP1A23D6<br>3 - 32 VDC<br>RP1B23D3 RP1B23D5 RP1B23D6<br>230 VACrms 650 Vp<br>16 - 32 VAC - - RP1A23A6<br>3 - 32 VDC RP1A40D3 RP1A40D5 RP1A40D6<br>400 VACrms 850 Vp<br>4 - 32 VDC RP1B40D3 RP1B40D5 RP1B40D6<br>RP1A48D3 RP1A48D5 RP1A48D6<br>480 VACrms 1000 Vp 4 - 32 VDC<br>RP1B48D3 RP1B48D5 RP1B48D6<br>**----- End of picture text -----**<br> **2** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** ## **Selection guide: mounted on DIN EN adaptor** **==> picture [483 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Rated operational current<br>Blocking Control<br>operational<br>voltage voltage 3 AACrms 5 AACrms 5.5 AACrms<br>voltage<br>RP1A23D3M1 RP1A23D5M1 RP1A23D6M1<br>5 - 34 VDC<br>RP1B23D3M1 RP1B23D5M1 RP1B23D6M1<br>230 VACrms 650 Vp<br>16 - 32 VAC - - RP1A23A6M1*<br>480 VACrms 1000 Vp 6 - 34 VDC - RP1A48D5M2 -<br>**----- End of picture text -----**<br> - Version RP1A23A6M1 does not include an LED on the DIN adaptor. ## **Carlo Gavazzi compatible components** **==> picture [483 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Description Component code Notes<br>**----- End of picture text -----**<br> |**Description**|**Component code**|**Notes**| |---|---|---| |||| |**DIN adaptors**|RPM1*<br>RPM1V*<br>RPM1P<br>RPM1PD*<br>RPM2|DIN adaptor 250 V with LED<br>DIN adaptor 250 V with LED + varistor<br>DIN adaptor 250 V with pins for removal of RP<br>DIN adaptor 250 V with pins for removal of RP + LED<br>DIN adaptor 600 V with LED| - Not suitable for use with RP1A23A6 **3** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** ## **Features** ## **General data** |**Material**<br>P|BT, RAL7035| |---|---| |**Potting compound**<br>F|lame-retardant fexible silicone rubber| |**Weight**<br>A|pprox. 20 g| |**Isolation**<br>I|nput to output: ≥ 4000 VACrms| |**Insulation resistance**<br>1|010Ω| |**Insulation capacitance**<br>8|pF| ## **Dimensions** **==> picture [6 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>**----- End of picture text -----**<br> Dimensions in mm unless otherwise noted. Tolerances +/- 0.5 mm. **4** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** ## **Performance** **==> picture [483 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> Mains supply<br>RP1..23.. RP1..40.. RP1..48..<br>Operational voltage range<br>RP1A 12 - 265 VACrms 20 - 440 VACrms 20 - 530 VACrms<br>RP1B 12 - 265 VACrms 12 - 440 VACrms 12 - 530 VACrms<br>Operational frequency range 45 - 65 Hz<br>Blocking voltage 650 Vp 850 Vp 1000 Vp<br>Zero voltage turn-on < 10 V<br>**----- End of picture text -----**<br> **==> picture [483 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> Outputs<br>RP1..3 RP1..5 RP1..6<br>Rated operational current<br>AC 51 @ Ta = 25°C 3 A 5 A 5.5 A<br>AC 53a @ Ta = 25°C 2 A 3 A 5 A<br>Minimum operational current 20 mA<br>Power factor > 0.5<br>Rep. overload current t=1 s 10 AACrms 12 AACrms 16 AACrms<br>Non-repetitive surge current<br>65 Ap 80 Ap 250 Ap<br>(ITSM), t=20 ms<br>< 1 mA<br>Off-state leakage current<br>I²t for fusing (t=10 ms) 20 A [2] s 50 A [2] s 340 A [2] s<br>Critical dV/dt off state min. 250 V/μs 500 V/μs<br>On-state voltage drop @ rated<br>< 1.2 Vrms<br>current<br>**----- End of picture text -----**<br> **5** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** **==> picture [484 x 277] intentionally omitted <==** **----- Start of picture text -----**<br> Inputs<br>RP1..D.. RP1..D..M.. RP1A23A6<br>Control voltage 16 - 32 VAC<br>RP1..23.. RP1A40.. 3-32 VDC 5-34 VDC -<br>RP1B40.. RP1..48.. 4-32 VDC 6-34 VDC -<br>Pick-up voltage 10 VAC<br>RP1..23.. RP1A40.. 2.8 VDC 4.8 VDC -<br>RP1B40.. RP1..48.. 3.8 VDC 5.8 VDC -<br>Drop-out voltage 1.2 VDC 5 VAC<br>Max. input curent 13 mAAC<br>RP1A 10 mADC -<br>RP1B 15 mADC -<br>Max. reverse voltage 32 VDC 34 VDC -<br>Response time pick-up<br>RP1A < 10 ms < 20 ms<br>RP1B < 160 μs (12 VDC / 50 Hz) -<br>-<br>< 320 μs (5 VDC / 50 Hz)<br>Response time drop-out < 20 ms<br>RP1A < 10 ms -<br>RP1B < 10 ms -<br>**----- End of picture text -----**<br> ## **Current derating** **==> picture [483 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> 6<br>5<br>4<br>RP1..6<br>3<br>RP1..5<br>RP1..3<br>2<br>1<br>0<br>20 25 30 35 40 45 50 55 60 65 70<br>Surrounding ambient temperature (°C)Surrounding ambient temperature (°C)<br>Load current (AAC)<br>Load current (AAC)<br>**----- End of picture text -----**<br> When used at full load current, the relays must be placed vertically. If more than one relay is mounted, please allow a minimum distance of 20 mm in between for sufficient air cooling. **6** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** ## **Current derating with 0 mm spacing** **==> picture [483 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>2.5<br>2<br>1.5 RP1..6<br>RP1..5<br>RP1..3<br>1<br>0.5<br>0<br>20 25 30 35 40 45 50 55 60 65 70<br>Surrounding ambient temperature (°C)Surrounding ambient temperature (°C)<br>Load current (AAC)Load current (AAC)<br>**----- End of picture text -----**<br> ## **Increased current options** **==> picture [20 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> Ipeak<br>Inom<br>Tamb<br>**----- End of picture text -----**<br> ## t |**Ipeak (Amps)**|6|8|10| |---|---|---|---| |**D5 : t (minutes)**|15|5|3| |**D6 : t (minutes)**|||| Note: even though the D3 can withstand a slight increase in current for a limited time, it is not recommended for this purpose. **7** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** ## **Compatibility and conformance** **Approvals** ~~«(CEBAss FA~~ LVD: EN 60947-4-3 EMCD: EN 60947-4-3 **Standards compliance** cURus: UL508 Recognized (E80573), NRNT2, NRNT8 CSA: C22.2 No. 14 (204075) VDE: VDE 0600-100, VDE 0600-109 (excluding RP1A23A6) |**Electromagnetic compatibility (EMC) - Immunity**|**Electromagnetic compatibility (EMC) - Immunity**| |---|---| |**Electrostatic discharge (ESD)**|EN/IEC 61000-4-2<br>8 kV air discharge, 4 kV contact(PC1)| |**Radiated radio frequency**|EN/IEC 61000-4-3<br>10 V/m, from 80 MHz to 1 GHz (PC1)<br>10 V/m, from 1.4 to 2 GHz (PC1)<br>10 V/m,from 2 to 2.7 GHz(PC1)| |**Electrical fast transient (burst)**|EN/IEC 61000-4-4<br>Output: 2 kV, 5 kHz (PC2)<br>Input: 1 kV,5 kHz(PC2)| |**Conducted radio frequency**|EN/IEC 61000-4-6<br>10 V/m,from 0.15 to 80 MHz(PC1)| |**Electrical surge**|EN/IEC 61000-4-5<br>Output, line to line: 1 kV (PC2)<br>Output, line to earth: 1 kV (PC2)1<br>Input, line to line: 500 V (PC2)2<br>Input, line to earth: 500 V(PC2)2| |**Voltage dips**|EN/IEC 61000-4-11<br>0% for 0.5, 1 cycle (PC2)<br>40% for 10 cycles (PC2)<br>70% for 25 cycles (PC2)| |**Voltage interruptions**|EN/IEC 61000-4-11<br>0% for 5000 ms(PC2)| 1. A suppression device, such as a varistor, needs to be connected across the output terminals L1, T1 for immunity against higher voltage levels. 2. A suppression device, such as a transil, needs to be connected across the control terminals A1, A2 for immunity against higher voltage levels. |**Electromagnetic compatibility (EMC) - Emissions**|**Electromagnetic compatibility (EMC) - Emissions**| |---|---| |**Radio interference field**<br>**emission (radiated)**|EN/IEC 55011<br>Class A: from 30 to 1000 MHz| |**Radio interference voltage**<br>**emissions (conducted)**|EN/IEC 55011<br>Class A: from 0.15 to 30 MHz, with filter capacitor across the mains supply.*| * For conformance to EN/IEC 55011, an external capacitor class X1, 100 nF is to be connected across the output terminals 1-2. ## Note: - Control input lines must be installed together to maintain products’ susceptability to Radio Frequency interference. - Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. - Use of mains filters may be necessary for cases where the user must meet E.M.C requirements. - Performance Criteria 1 (PC1): No degradation of performance or loss of function is allowed when the product is operated as intended. - Performance Criteria 2 (PC2): During the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself. - Performance Criteria 3 (PC3): Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. **8** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** **==> picture [37 x 37] intentionally omitted <==** ## **Environmental specifications** |**Operating temperature**|-20°C to +70°C (-4°F to +158°F)| |---|---| |**Storage temperature**|-40°C to +100°C (-40°F to +212°F)| |**Pollution degree**|2| |**EU RoHS compliant**|Yes| |**China RoHS**|25| The declaration in this section is prepared in compliance with People’s Republic of China Electronic Industry Standard SJ/ T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products. |**Part Name**|**Toxic or Hazardous Substances and Elements**|**Toxic or Hazardous Substances and Elements**|**Toxic or Hazardous Substances and Elements**|**Toxic or Hazardous Substances and Elements**|**Toxic or Hazardous Substances and Elements**|**Toxic or Hazardous Substances and Elements**| |---|---|---|---|---|---|---| ||Lead<br>(Pb)|Mercury<br>(Hg)|Cadmium<br>(Cd)|Hexavalent<br>Chromium<br>(Cr(Vl))|Polybrominat-<br>ed biphenyls<br>(PBB)|Polybromi-<br>nated diphenyl<br>ethers (PBDE)| |**Power Unit**<br>**Assembly**|x|O|O|O|O|O| |O: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit<br>requirement of GB/T 26572.<br>X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above<br>the limit requirement of GB/T 26572.||||||| ## 这份申明根据中华人民共和国电子工业标准 ## SJ/T11364-2014:标注在电子电气产品中限定使用的有害物质 |零件名称|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素| |---|---|---|---|---|---|---| ||铅<br>(Pb)|汞<br>(Hg)|镉<br>(Cd)|六价铬<br>(Cr(Vl))|多溴化联苯<br>(PBB)|多溴联苯醚<br>(PBDE)| |功率单元|x|O|O|O|O|O| |O:此零件所有材料中含有的该有害物低于GB/T 26572的限定。<br>X: 此零件某种材料中含有的该有害物高于GB/T 26572的限定。||||||| **9** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd. **RP1A, RP1B** ## **Functional diagram: RP1..** **==> picture [385 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> Pe<br>1<br>(+) 3 REGULATION<br>ZC *<br>Control Control IO<br>input input<br>2<br>_4<br>(-) 4 y e Ht<br>ZC - Zero Crossing<br>IO - Instant On<br>|<br>**----- End of picture text -----**<br> **==> picture [477 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> Functional diagram: RP1..Mx<br>><br> fp<br>(+) 3 1 1<br>(+) 3 V— ¢) REGULATION ) 0)<br>ZC *<br>Control Control IO<br>input input<br>2<br>(-) 4 Z 1 ME —7,<br>(-) 4 2<br>**----- End of picture text -----**<br> * The varistor is not included in the solid state relay. Connecting a varistor across terminals 1-2 helps protect the solid state relay against damages by over-voltage. |**Connection specifications**<br>>|| |---|---| |**Terminals**|Copper alloy, tin-plated| |**Terminals soldering temperature**|Max. 300°C for 5 seconds| COPYRIGHT ©2026 Content subject to change. Download the PDF: https://gavazziautomation.com **10** 02/01/2026 RP1A, RP1B DS ENG Carlo Gavazzi Ltd.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →