RAC20-05SK/W
AC/DC PCB Mount Power Supply (PSU), ITE & Household, 1 Output, 20 W, 5 VDC, 4 A
- Manufacturer: RECOM POWER
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:20W; Output Voltage - Output 1:5V; Output Current - Output 1:4A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output 3:
- SVHC: No SVHC (04-Feb-2026)
- Depth: 52.5mm
- Width: 27.4mm
- Height: 23mm
- Product Range: RAC20-K/W Series
- No. of Outputs: 1 Output
- Output Power Max: 20W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 9.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
• Wide input range 85-264VAC / 85-305VAC Features • Standby mode optimized PSU (ENER Lot 6) • Operating Altitude up to 5000m **AC/DC Converter** • Operating temperature range: -40°C to +85°C Regulated • Class II installations (without FG) Converter • EMC compliant without external components **RAC20-K** • No load power consumption 40mW typ. ee Description — **20 Watt** NEAR The RAC20-K series are highly efficient PCB-mount power conversion modules with ultra-low **3** energy losses especially in light load conditions, making them a benchmark for always-on and standby **2“ x 1“** <p> mode operations, which are typically coming along with IoT and smart applications. The power supply units cover worldwide mains input range of 85VAC up to 305VAC and come with international safety **Single and** certifications for industrial, AV and ITE as well as household standards. These AC/DC modules operate in a temperature range of -40°C to +85°C with up to 5000m operating altitude and offer fully protected **Dual Output** single or dual outputs as well as EMC class B compliance without the need of any external components in floating connections. Modified versions for OVC III requirements are available on request. ## Selection Guide |Part|Input|Output|Output|Efficiency|Max. Capacitive| |---|---|---|---|---|---| |Number|Voltage Range|Voltage|Current|typ(1)|Load(2)| ||[VAC]|[VDC]|[mA]|[%]|[µF]| |RAC20-05SK(3,4)|85-264 / 85-305|5|4000|84|10000| |RAC20-12SK(3,4)|85-264 / 85-305|12|1670|86|8000| |RAC20-15SK(3,4)|85-264 / 85-305|15|1333|86|1500| |RAC20-24SK(3,4)|85-264 / 85-305|24|830|85|1000| |RAC20-48SK(3)|85-264|48|410|85|330| |RAC20-12DK|85-264|±12|±833|84|±1200| |RAC20-15DK|85-264|±15|±670|84|±1000| Notes: Note1: Efficiency is tested at 230VAC input and constant resistive load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load ## Model Numbering ~~OO~~ **==> picture [475 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> OO |<br>RAC20- K/W/277 RoHScompliant10 from 102+ REACHcompliant ERPLOT6 compliant<br>nom. Output Power Input Voltage option [(4)]<br>Output Voltage W ired option<br>CERTIFIED<br>S ingle or D ual EN-60335-1 E224736<br>@ CEN:®<br>Notes:<br>Note3: Add suffix „W“ for wired version (only single output)<br>without suffix, standard THT version CB<br>Note4: Add suffix “/277” for wider input voltage range (85-30VAC) SCHEMiTECEEi FAL<br>For more information refer to “Nominal Input Voltage (5, 6)”<br>E<br>T T<br>O O<br>i<br>N N<br>a<br>N P N P<br>C C<br>S<br>l<br>V<br>R<br>V<br>R<br>H<br>A A<br>n<br>E<br>O<br>E<br>I O I<br>M M<br>p<br>L L<br>U<br>R R<br>D D<br>O<br>P P<br>c<br>O T O T<br>U U<br>p<br>O<br>C C<br>M M<br>E E<br>C C<br>L<br>e<br>E R E R<br>O T O T<br>a<br>R R<br>H<br>s<br>S<br>S<br>S<br>C S C<br>D<br>**----- End of picture text -----**<br> IEC/EN62368-1 certified UL62368-1 certified CAN/CSA-C22.2 No. 62368-1-14 certified IEC/EN60335 certified * IEC/EN61558-1 certified * IEC/EN61558-2-16 certified * IEC/EN61204-3 compliant * EN55032/14 compliant * EN55024 compliant * CB Report Ordering Examples: RAC20-05SK 85-264VAC 5Vout Single Output THT RAC20-05SK/W 85-264VAC 5Vout Single Output wired RAC20-12DK 85-264VAC 12Vout Dual Output THT RAC20-05SK/277 85-305VAC 5Vout Single Output THT RAC20-15SK/277 85-305VAC 15Vout Single Output THT * „/277“ models pending REV.: 7/2021 PA-1 **www.recom-power.com** ## **RAC20-K** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) |BASIC CHARACTERISTICS|BASIC CHARACTERISTICS||||||| |---|---|---|---|---|---|---|---| |Parameter||Condition|||Min.|Typ.|Max.| |Internal Input Filter|||||Pi type||| |Nominal Input Voltage(5, 6)||50/60Hz|standard version<br>“/277” version||100VAC||240VAC<br>277VAC| |Operating Range||standard|47-63Hz<br>DC||85VAC<br>120VDC||264VAC<br>370VDC| |||/277 Versions|47-63Hz<br>DC||85VAC<br>120VDC||305VAC<br>430VDC| |Input Current||115VAC<br>230VAC<br>277VAC|||||450mA<br>400mA<br>300mA| |Inrush Current||cold start at +25°C||115VAC<br>230VAC<br>277VAC|||20A<br>40A<br>50A| |No Load Power Consumption||230VAC||||40mW|| |ErP Lot 6 Standby Mode Conformity (Output Load<br>Capability)||Input Power =<br>0.5W<br>1.0W<br>2.0W|||||0.3W<br>0.7W<br>1.6W| |Input FrequencyRange||AC Input|||47Hz||63Hz| |Minimum Load(9)||single<br>dual(required for regulation on both outputs)|||0%|10%|| |Power Factor||115VAC<br>230VAC<br>277VAC|||0.6<br>0.5<br>0.45||| |Start-upTime||||||150ms|| |Rise Time||||||40ms|| |Hold-up Time||115VAC<br>230VAC<br>277VAC||||12ms<br>60ms<br>90ms|| |Internal OperatingFrequency|||||||100kHz| |Output Ripple and Noise(7)||20MHz BW|5Vout<br>others|||100mVp-p|1% of Vout| |continued on nextpage<br>Effciency vs. Load<br>Notes:<br>Note5: The products were submitted for safety fles at AC-Input operation<br>Note6: Refer to_“Derating Graph”_<br>Note7: Measurements are made with a 1.0µF MLCC across output (low ESR)<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]<br>Output Load [%]<br>~~115VAC~~<br>230VAC<br>277VAC<br>RAC20-05SK(W)<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]<br>Output Load [%]<br>~~115VAC~~<br>230VAC<br>277VAC<br>RAC20-12SK(W)|Notes:||||||| REV.: 7/2021 PA-2 **www.recom-power.com** ## **RAC20-K** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) **==> picture [526 x 208] intentionally omitted <==** **----- Start of picture text -----**<br> Efficiency vs. Load<br>RAC20-15DK RAC20-24SK(W)<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 115VAC 30 115VAC<br>20 230VAC 20 230VAC<br>277VAC 277VAC<br>10 10<br>0 0<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> ## REGULATIONS |REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS|REGULATIONS| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Parameter||||||||||Condition|||Value| |Output Accuracy|||||||||||||±2.0% typ.| |Line Regulation||||||||||low line to high line|||±0.5% typ.| |Load Regulation(8)||||||||||10% to 100% load|||2.0% typ.| |Cross Regulation||||||||||dual output only|||±10.0% typ.| |Transient Response||||||||||25% load step change<br>recoverytime|||4.0% max.<br>500µs typ.| |2<br>1<br>0<br>-1<br>1.5<br>0.5<br>-0.5<br>-1.5<br>-2<br>Deviation [%]<br>0<br>10<br>Deviation vs. Load<br>2<br>1<br>0<br>-1<br>1.5<br>0.5<br>-0.5<br>-1.5<br>-2<br>Deviation [%]<br>0<br>10|||20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>Output Load [%]<br>115VAC<br>~~230VAC~~<br>277VAC<br>RAC20-05SK(W)<br>2<br>1<br>0<br>-1<br>1.5<br>0.5<br>-0.5<br>-1.5<br>-2<br>Deviation [%]<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>Output Load [%]<br>115VAC<br>~~230VAC~~<br>277VAC<br>RAC20-12SK(W)<br>Notes:<br>Note8: Operation below 10% load will not harm the converter, but specifcations may not be met<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>Output Load [%]<br>115VAC<br>~~230VAC~~<br>277VAC<br>RAC20-15SK(W)<br>2<br>1<br>0<br>-1<br>1.5<br>0.5<br>-0.5<br>-1.5<br>-2<br>Deviation [%]<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>Output Load [%]<br>115VAC<br>~~230VAC~~<br>277VAC<br>RAC20-24SK(W)||||||||||| ||||||||||||||| ||||||||||||115V<br>~~230V~~|AC<br>~~AC~~|| ||||||||||||||| ||||||||||||277V|AC|| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||0<br>10||||||||||||| ||||||||||||||| ||||||||||||115V<br>~~230V~~|AC<br>~~AC~~|| ||||||||||||||| ||||||||||||277V|AC|| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||0<br>10||20<br>30<br>40<br>50<br>60<br>Output Load [%]||||||||||| REV.: 7/2021 PA-3 **www.recom-power.com** ## **RAC20-K** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) |PROTECTIONS|PROTECTIONS|PROTECTIONS|PROTECTIONS|PROTECTIONS| |---|---|---|---|---| |Parameter||Type||Value| |Input Fuse(9)||internal|standard version|T3.15A, slow blow type| ||||/277 versions|non, refer to_“Protection Circuit”_| |Short Circuit Protection(SCP)||below 100mW||hiccup, auto recovery| |Over Voltage Protection(OVP)||||150% - 195%, latch off mode| |Over Current Protection(OCP)||||110% - 130%, hiccupmode| |Over Voltage Category (10)||||OVCII| |Class of Equipment||||ClassII| |Isolation Voltage(11)||I/P to O/P|tested for 1 minute|3kVAC| |Isolation Resistance|||Viso= 500VDC|1GWmin.| |Isolation Capacitance||||100pF max.| |Insulation Grade||||reinforced| |Leakage Current||||0.25mA max.| |Notes:<br>Note9: Refer to local safety regulations if input over-current protection is also required<br>/277 Versions have no fuse integrated, it is recommended to use an external fuse recognized by<br>UL or evaluated by TUV, refer to below schematic<br>Note10: For OVC III requirements please contact RECOM tech support for advice<br>Note11: For repeat Hi-Pot testing, reduce the time and/or the test voltage<br>-Vout<br>+Vout<br>L<br>N<br>F<br>VACin(L)<br>VACin(N)<br>+Vout<br>-Vout<br>Protection Circuit for /277 Versions|Notes:|||| |ENVIRONMENTAL|ENVIRONMENTAL|||| |---|---|---|---|---| |Parameter||Condition||Value| |Operating Temperature Range||@ natural convection 0.1m/s|full load|-40°C to +55°C| ||||refer to_“Derating Graph”_|-40°C to +85°C| |Maximum Case Temperature||||+95°C| |Temperature Coeffcient||||0.05%/K| |OperatingAltitude(12)||||5000m| |OperatingHumidity||non-condensing||20% - 90% RH max.| |IP Rating||||IP20| |Pollution Degree||||PD2| |Vibration||accordingto MIL-STD-202G||10-500Hz, 2G 10min./1cycle,period 60min. alongx,y,z axes| |Design Lifetime||+25°C||130 x 10³ hours| |||+55°C||16 x 10³ hours| |MTBF||according to MIL-HDBK-217F, G.B.|+25°C<br>+40°C|>1196 x 103hours<br>>955 x 103hours| ||Notes:|||| REV.: 7/2021 PA-4 **www.recom-power.com** **Series** ## **RAC20-K** ## **AC/DC Converter** **==> picture [526 x 257] intentionally omitted <==** **----- Start of picture text -----**<br> Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)<br>Derating Graph<br>(@ Chamber and natural convection 0.1m/s) 100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>-40 -20 0 20 40 60 80 100<br>55 85<br>Ambient Temperature [°C]<br>Notes:<br>Note13: Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 90% at 85VAC)<br>Output Load [%]<br>**----- End of picture text -----**<br> |SAFETY ANDCERTIFICATIONS|SAFETY ANDCERTIFICATIONS|| |---|---|---| |Certifcate Type(Safety)|Report / File Number|Standard| |Audio/Video, information and communication technology equipment -<br>Safetyrequirements|E224736|UL62368-1, 2nd Edition, 2014<br>CAN/CSA C22.2 Nr. 62368-1-14,2nd Ed. 2014| |Audio/Video, information and communication technology equipment -<br>Safetyrequirements(CB Scheme)|E491408-A6008-CB-1|IEC62368-1:2014 2nd Edition| |Audio/Video, information and communication technology equipment -<br>Safetyrequirements(LVD)||EN62368-1:2014 + A11:2017| |Household and similar electrical appliances – Safety – Part 1: General requirements|LCS180508046AS<br>(“/277” modelspending”|IEC60335-1:2010 + AMD2:2016 + COR1:2016<br>EN60335-1:2012 + A11:2014 + A13:2017| |Safety of power transformers, power supplies, reactors and similar products for<br>supplyvoltages upto 1100 V (CB Scheme)|50198090 001<br>(“/277” models pending”|IEC61558-1:2005 2nd Edition + A1:2009| |Safety of power transformers, power supplies, reactors and similar products for<br>supplyvoltages upto 1100 V||EN61558-1:2005 + A1:2009| |Safety of power transformers, power supplies, reactors and similar products for<br>supplyvoltages upto 1100 V Part 2: Particular requirements (CB Scheme)|50198090 001<br>(“/277” models pending”|IEC61558-2-16:2009 1st Edition + A1:2013| |Safety of power transformers, power supplies, reactors and similar products for<br>supplyvoltages upto 1100 V Part 2: Particular requirements||EN61558-2-16:2009 + A1:2013| |EAC|RU-AT.03.67361|TP TC 004/2011| |RoHS2||RoHS-2011/65/EU + AM-2015/863| |||| |EMC Compliance(“/277” modelspending)|Condition|Standard / Criterion| |Low voltagepower supplies, d.c. output Part 3: Electromagnetic compatibility (EMC)||IEC/EN61204-3:2018, Class B| |Electromagnetic compatibilityof multimedia equipment - Emission requirements|without external flter|EN55032:2015, Class B| |Electromagnetic compatibility of household appliances, electric tools and similar<br>apparatus - Emission Requirements||EN55014-1:2006 + A2:2011| |Information technologyequipment - Immunitycharacters - Limits and methods of measurement||EN55024:2010 + A1:2015| |Electromagnetic compatibility of household appliances, electric tools and similar<br>apparatus - ImmunityRequirements||EN55014-2:2015| |ESD Electrostatic discharge immunitytest|Air ±8kV, Contact ±4kV|EN61000-4-2:2009, Criteria B| |Radiated, radio-frequency, electromagnetic feld immunity test|80MHz - 6GHz: 10V/m<br>1.4GHz - 2GHz: 3V/m<br>2.0GHz - 2.7GHz: 1V/m|EN61000-4-3:2006 + A1:2008, Criteria A| |continued on nextpage||| REV.: 7/2021 PA-5 **www.recom-power.com** **Series** ## **RAC20-K** ## **AC/DC Converter** |Specifcations(measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)|Specifcations(measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)|Specifcations(measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)|Specifcations(measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)| |---|---|---|---| ||||| |EMC Compliance||Condition|Standard / Criterion| |Fast Transient and Burst Immunity||AC Port: ±2.0kV<br>DC Port: ±2.0kV|EN61000-4-4:2012, Criteria B| |Surge Immunity||AC Port: L-N ±1.0kV<br>DC Port: ±0.5kV|EN61000-4-5:2014 + A1:2017, Criteria B| |Immunity to conducted disturbances, induced by radio-frequency felds||AC Port: 10V<br>DC Port: 10V|EN61000-4-6:2014, Criteria A| |Power Magnetic Field Immunity||50Hz, 30A/m|EN61000-4-8:2010, Criteria A| |Voltage Dips and Interruptions||Voltage Dips 20%<br>Voltage Dips 30%<br>Voltage Dips 60%<br>Voltage Dips 100%<br>Voltage Interruptions > 95%|EN61000-4-11:2004 + A1:2017, Criteria C<br>EN61000-4-11:2004 + A1:2017, Criteria C<br>EN61000-4-11:2004 + A1:2017, Criteria C<br>EN61000-4-11:2004 + A1:2017, Criteria B<br>EN61000-4-11:2004 + A1:2017, Criteria C| |Limits of Voltage Fluctuations & Flicker|||EN61000-3-3:2013| |Limitations on the amount of electromagnetic interference allowed from digital and electronic devices|||FCC 47 CFR Part 15 Subpart B, Class B| |American National Standard for Methods of Measurement of Radio-Noise Emissions from<br>Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz|||ANSI C63.4-2014, Class B| ||Notes:<br>Note14: If output is connected to GND, please contact RECOM tech support for advice||| **==> picture [526 x 431] intentionally omitted <==** **----- Start of picture text -----**<br> DIMENSION AND PHYSICAL CHARACTERISTICS<br>Parameter Type Value<br>case black plastic, (UL94V-0)<br>potting silicone, (UL94V-0)<br>Material<br>PCB FR4, (UL94V-0)<br>baseplate black plastic, (UL94V-0)<br>Dimension (LxWxH) 52.5 x 27.4 x 23.0mm<br>pin 60g typ.<br>Weight<br>wired 65g typ.<br> Dimension Drawing (mm)<br>52.5<br>embossed logo Pinning information<br>Pin # Single Dual<br>1 VAC in (N) VAC in (N)<br>2 VAC in (L) VAC in (L)<br>51.0 26.3<br>3 no pin -Vout<br>4 -Vout Com<br>5 +Vout +Vout<br>Tolerance: xx.x= ±0.5mm<br>xx.xx= ±0.25mm<br>Ø1.0 [±0.1] 20.32<br>Recommended Footprint Details<br>2 3 1 5<br>Bottom View 4 Top View 4<br>1 5 2 3<br>3.39 18x2.54= 45.72 2.54<br>continued on next page<br>27.4<br>23.0<br>±1.0<br>6.0<br>10.16<br>2. 54<br>3.50 10.16<br>**----- End of picture text -----**<br> REV.: 7/2021 PA-6 **www.recom-power.com** ## **RAC20-K** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) **==> picture [513 x 389] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing Single Wired (mm)<br>52.5<br>embossed logo<br>51.0 26.3<br>Ø2.9<br>Wired information<br>2<br># Function Wire color Type AWG<br>Bottom View 4 1 VAC in (N) blue UL-1015 18<br>2 VAC in (L) brown UL-1015 18<br>1 5 4 -Vout black UL-1015 18<br>5 +Vout red UL-1015 18<br>Tolerance: xx.x= ±0.5mm<br>xx.xx= ±0.25mm<br>27.4<br>23.0<br>100.0±10<br>5 ±2<br>**----- End of picture text -----**<br> |PACKAGING INFORMATION|PACKAGING INFORMATION|PACKAGING INFORMATION|PACKAGING INFORMATION| |---|---|---|---| |Parameter|Type||Value| |Packaging Dimension (LxWxH)|pin<br>wired|tube<br>tray|490.0 x 56.0 x 40.0mm<br>488.0 x 202.0 x 47.0mm| |Packaging Quantity|tube<br>tray||15pcs<br>20pcs| |Storage Temperature Range|||-40°C to +85°C| |Storage Humidity|non-condensing||20% to 90% RH max.| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 7/2021 PA-7 **www.recom-power.com**
Updated at June 3, 2026
RECOM Power is a globally recognized manufacturer specializing in standard and customized power conversion solutions. Headquartered in Austria with state-of-the-art research and development facilities, the company has built a strong reputation for innovation and reliability. Operating from ISO 9001 and IATF 16949 certified manufacturing sites, RECOM delivers premium power supplies engineered for demanding applications across IoT, Industry 4.0, medical technology, and transportation. The core of our RECOM Power portfolio is dedicated to advanced power and line protection, featuring an extensive selection of high-performance AC/DC converters. These modules are designed to provide efficient, stable power distribution for a wide array of industrial and commercial electronics. In addition to general-purpose power supplies, we offer a robust range of AC/DC LED power supplies specifically optimized to meet the stringent efficiency and lifespan requirements of modern lighting systems. To support comprehensive power architecture design, our selection also includes highly efficient DC/DC converters ideal for precise voltage regulation in complex circuits. Furthermore, we provide specialized passive components such as RECOM power inductors, ensuring engineers have access to the critical, high-quality components required to develop resilient and optimized power delivery systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.