R45C-K-UQ.
SIGNAL CONVERTER, 1-CH, VOLTAGE, 30VDC
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- Signal Conditioner Input:-; Signal Conditioner Output:Voltage; No. of Output Channels:1Channels; Accuracy:0.5%; Output Accuracy:-; Supply Voltage:30VDC; No. of 30AK5460
- Accuracy %: 0.5%
- Product Range: R45C Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 1 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: -
- Signal Conditioner Output: Voltage
- Signal Conditioner Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 113.91 € |
| Current stock | 10+ |
| Lead time | 30 days |
R45C Analog Converter (Voltage and Current) IO-Link Data Reference Guide ## IO-Link Data Map This document refers to the following IODD file: Banner_Engineering-R45C-IU-20200715-IODD1.1.xml. The IODD file and support files can be found on www.bannerengineering.com under the download section of the product family page. ## Communication Parameters The following communication parameters are used. |**Parameter**|**Value**|**Parameter**|**Value**| |---|---|---|---| |IO-Link revision<br>Process Data In length<br>Process Data Out length<br>Bit Rate<br>Minimum cycle time<br>Device ID|V1.1|Port class|A| ||32 bits|SIO mode|Yes| ||32 bits|Smart Sensor Profile|Yes| ||38400 bps|Block parameterization|Yes| ||4.8 ms|Data Storage|Yes| ||659470||| ## IO-Link Process Data In (Device to Master) Two analog files are supported by the IODD file. The voltage model is presented in mV and the current model is presented in µA. If the model is the voltage version (V_ModelType = 0), then Process Data Input = value × 0.001 V. If the model is the current version (V_ModelType = 1), then Process Data Input = value × 0.000001 A. PDI only on models = R45C-KI-IQ, R45C-KU-UQ, R45C-K-IIQ, R45C-K-UUQ ## Process Data Input Configuration - Analog Data |**Subindex**|**Subindex**|**Name**|**Name**|**Name**|**Name**|**Number of Bits**|**Number of Bits**|**Number of Bits**|**Data Values**|**Data Values**|**Data Values**| |---|---|---|---|---|---|---|---|---|---|---|---| |1||Measurement Value||||32|||The measurement device value||| ||||||||||||| |**Octet 0**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|31||30|29|28||27|26||25|24| |Value|0||0|0|0||0|0||0|1| |**Octet 1**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|23||22|21|20||19|18||17|16| |Value|1||1|1|1||1|1||0|1| |**Octet 2**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|15||14|13|12||11|10||9|8| |Value|1||1|1|1||1|1||1|0| |**Octet 3**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|7||6|5|4||3|2||1|0| |Value|1||1|1|1||1|1||1|0| ## Example Based Upon the Value Above Measurement Value = 509 Scaled Measurement Value = 0.509 V Original Document 223174 Rev. A 17 February 2022 223174 R45C Analog Converter (Voltage and Current) IO-Link Data Reference Guide ## Process Data Input Configuration - Digital Measuring Sensor |**Subindex**|**Subindex**|**Name**|**Name**|**Name**|**Name**|**Number of Bits**|**Number of Bits**|**Number of Bits**|**Data Values**|**Data Values**|**Data Values**| |---|---|---|---|---|---|---|---|---|---|---|---| |1||Measurement Value||||16|||The measurement device value||| |2||Measurement Scale||||8|||The measurement device scale<br>Voltage = -3<br>Current = -6||| ||||||||||||| |**Octet 0**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|31||30|29|28||27|26||25|24| |Value|0||0|0|0||0|0||0|1| |**Octet 1**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|23||22|21|20||19|18||17|16| |Value|1||1|1|1||1|1||0|1| |**Octet 2**|||||||||||| |Subindex|2||2|2|2||2|2||2|2| |Bit offset|15||14|13|12||11|10||9|8| |Value|1||1|1|1||1|1||1|0| |**Octet 3**|||||||||||| |Subindex|///||///|///|///||///|///||///|///| |Bit offset|7||6|5|4||3|2||1|0| |Value|1||1|1|1||1|1||1|0| ## Example Based Upon the Value Above Measurement Value = 509 Measurement Scale = -3 Scaled Measurement Value = 0.509 V ## IO-Link Process Data Out (Master to Device) If the model is the voltage version (V_ModelType = 0), then Process Data Input = value × 0.001 V. If the model is the current version (V_ModelType = 1), then Process Data Input = value × 0.000001 A. ## Process Data Output |**Subindex**|**Subindex**|**Name**|**Name**|**Name**|**Name**|**Number of Bits**|**Number of Bits**|**Number of Bits**|**Data Values**|**Data Values**|**Data Values**| |---|---|---|---|---|---|---|---|---|---|---|---| |1||Analog Out Value||||32|||The value to send to the analog output||| ||||||||||||| |**Octet 0**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|31||30|29|28||27|26||25|24| |**Octet 1**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|23||22|21|20||19|18||17|16| |**Octet 2**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| |Bit offset|15||14|13|12||11|10||9|8| |**Octet 3**|||||||||||| |Subindex|1||1|1|1||1|1||1|1| P/N 223174 Rev. A 2 www.bannerengineering.com - Tel: + 1 888 373 6767 R45C Analog Converter (Voltage and Current) IO-Link Data Reference Guide |**Octet 3**||||||||| |---|---|---|---|---|---|---|---|---| |Bit offset|7|6|5|4|3|2|1|0| ## Parameters Set Using IO-Link These parameters can be read from and/or written to an R45C-K-analog converter. Also included is information about whether the variable in question is saved during Data Storage and whether the variable came from the IO-Link Smart Sensor Profile. Unlike Process Data In, which is transmitted from the IO-Link device to the IO-Link master cyclically, these parameters are read or written acyclically as needed. |**Index**|**Sub-**<br>**index**|**Name**|**Length**|**Value Range**|**Default**|**Access**<br>**Rights**|**Data**<br>**Storage?**|**Smart Sensor**<br>**Profile**| |---|---|---|---|---|---|---|---|---| |0|1-16|Direct Parameter Page 1 (incl.<br>Vendor ID & Device ID)||||ro||| |1|1-16|Direct Parameters Page 2||||rw||| |2||Standard Command||130 = Restore Factory Settings<br>162 = Start discovery<br>163 = Stop discovery||wo||y| |3||Data Storage Index (device-<br>specific list of parameters to be<br>stored)||||rw||| |4-11||_reserved by IO-Link_<br>_Specification_||||||| |**12**||**Device Access Locks**||||||| |12|1|Parameter Write Access Lock<br>_(deprecated)_||||||| |12|2|Data Storage Lock<br>_(deprecated)_||||||| |12|3|Local Parameterization Lock||0 = off, 1 = on|0|rw|y|| |12|4|Local User Interface Lock||0 = off, 1 = on|0|rw|y|| |16||Vendor Name string||Banner Engineering Corporation||ro||| |17||Vendor Text string||More Sensors. More Solutions.||ro||| |18||Product Name string||||ro||| |19||Product ID string||||ro||| |20||Product Text string||||ro||y| |21||Serial Number||||ro||| |23||Firmware Version||||ro||y| |24||App Specific Tag (user<br>defined)||||rw|y|y| |25-35||_reserved_||||||| |36||Device Status|8-bit integer|0 = Device is OK<br>1 = Maintenance required<br>2 = Out of specification<br>3 = Functional check<br>4 = Failure<br>5..255 Reserved||ro||| |37||Detailed Device Status|Array[6] of 3-octet|||ro||| |40||Process Data Input||_see Process Data In_||ro||| |41||Process Data Output||_see Process Data Out_||ro||| |**60**||**BDC1 Setpoints**||||||| |60|1|Setpoint SP1|32-bit Integer|SP1 Switchpoint = Analog In LED<br>lower switchpoint|0.004 A<br>0.2 V|rw||| |60|2|Setpoint SP2|32-bit Integer|SP1 Switchpoint = Analog In LED<br>upper switchpoint|0.02 A<br>10 V|rw||| |**61**||**BDC1 Configuration**||||||| |61|1|Switchpoint Logic_(deprecated)_|8-bit Uinteger|||||| |61|2|BDC Mode_(deprecated)_|8-bit Uinteger|||||| P/N 223174 Rev. A www.bannerengineering.com - Tel: + 1 888 373 6767 3 R45C Analog Converter (Voltage and Current) IO-Link Data Reference Guide |**Index**|**Sub-**<br>**index**|**Name**|**Length**|**Value Range**|**Default**|**Access**<br>**Rights**|**Data**<br>**Storage?**|**Smart Sensor**<br>**Profile**| |---|---|---|---|---|---|---|---|---| |61|3|Hysteresis|16-bit Uinteger|Hyteresis value for the switchpoint|0.0001 A<br>0.05 V|rw||| |**69**||**All-Time Run Time**||||||| |69|1|Run counter|32-bit Uinteger|0..2147483647||ro|y|| |**70**||**Resettable Run Time**||||||| |70|1|Run counter|32-bit Uinteger|0..2147483647|0|rw||| |**76**||**Vendor Specific**<br>**Configuration**||||||| |76|1|Process Data Input<br>Configuration|8-bit Uinteger|0 = Analog Value<br>1 = Digital Measurement Value|0|rw|y|| |76|2|IOL Filter Time|16-bit Uinteger||200|rw|y|| |76|3|PDO Outside Valid Range<br>(POVR)|8-bit Uinteger|0 = Hold<br>1 = Low<br>2 = High|1|rw|y|| |**78**||**All-Time Run Time Event**<br>**Time**||||||| |78|1|Event Time|32-bit Uinteger|0..2147483647|0|rw|y|| |**79**||**Resettable Run Time Event**<br>**Time**||||||| |79|1|Event Time|32-bit Uinteger|0..2147483647|0|rw|y|| |86||Model Type|8-bit Uinteger|0 = Voltage, 1 = Current|0|ro||| |**16512**||**MDC Descriptor**||**Measuring Data Channel**<br>**Descriptor - Smart Sensor Profile**<br>**2nd Edition**||||| |16512|1|Lower Limit|32-bit integer|||ro||| |16512|2|Upper Limit|32-bit integer|||ro||| |16512|3|Unit|16-bit uinteger|1209 = A, 1240 = V||ro||| |16512|4|Scale|8-bit integer|-6 (µA), -3 (mV)||ro||| ## IO-Link Events Events are acyclic transmissions from the IO-Link device to the IO-Link master. Events can be error messages and/or warning or maintenance data. |**Code**|**Type**|**Name**|**Description**| |---|---|---|---| |25376 (0x6320)|Error|Parameter error|Check data sheet and values| |36000 (0x8CA0)|Warning|All-time Run Time Event|Event indicating the corresponding configured running time<br>has elapsed.| |36001 (0x8CA1)|Warning|Resettable Run Time Event|Event indicating the corresponding configured running time<br>has elapsed.| © Banner Engineering Corp. All rights reserved
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →