PSG240F24RM
POWER SUPPLY, AC-DC, 24V, 10A
- Manufacturer: EATON
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:240W; Output Voltage - Output 1:24VDC; Output Current - Output 1:10A; Output Voltage - Output 2:-; Output Current -
- Product Range: PSG Series
- No. of Outputs: 1 Output
- Output Power Max: 240W
- Current, Output 4: -
- Input Voltage VAC: 320V AC to 600V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 10A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 290.79 € |
| Current stock | 50+ |
| Lead time | 30 days |
**DATASHEET - PSG240F24RM** **Power supply unit, 3-phase, 400-500VAC/24VDC, 10A** **Part no. PSG240F24RM Catalog No. 172884 Alternate Catalog PSG240F24RM No. EL-Nummer 4560882 (Norway)** ## **Delivery program** |**No.**<br>**EL-Nummer**<br>**(Norway)y)) **<br>**4560882**<br>**Deliveryy programrogramgramram**|||| |---|---|---|---| |Product range|||Power supplies PSG| |Subrange|||power supply unit| |Description|||Power Boost via 1.5-fold rated operational current for 5 s<br>PELV (EN 60204), SELV (EN 60950)| |Phases|||Three-phase| |Input voltage range|||320 - 600 V AC<br>(450 - 800 V DC)| |Nominal input voltage|||3 x 400 - 500 V AC| |Rated output voltage|||24 V DC (± 2%)| |Rated output current||A|10| |Setting range for the output voltage|||24 - 28 V DC| |Rated output power||W|240| ## **Technical data** ## **Input characteristics** |**Technical data**<br>**Input characteristicsput characteristicsut characteristics**|||| |---|---|---|---| |Nominal input voltage|||3 x 400 - 500 V AC| |Input voltage range||V|3 x 320 - 600 V AC| ||||2 x 360 - 600 V AC| ||||450 - 800 V DC| |Supply frequency|||| |Rated value||Hz|50/60| |Range||Hz|47 - 63| |Nominal current|In|A|< 0.75 bei 3 x 400 V AC| ||||< 0.65 bei 3 x 500 V AC| |Inrush current limitation I²t (+25 °C)||A|Voltage source up to 3 KVA: < 40 A with 3x 400 V AC & 3x 500 V AC| ||||Voltage source up to 18 KVA: < 60 A with 3x 400 V AC & 3x 500 V AC| |Mains buffering at nominal load||ms|| |Mains failure bridging||ms|> 20 with 3x 400 V AC| ||||>40 with 3x 500 V AC| |Run-up time after mains voltage applied||ms|< 1000| |Internal input fuse (device protection, not accessible)|||T3.15 AH/500 V, 600 V| |Back-up fuse|||3 x 6, 10, 16 A (recommended)| |Tripping characteristic|||B| |Leakage Current|||< 3.5 mA at 500 V AC| |Short-term interruption|||100% voltage dip, 1 cycle (20 ms at 50 Hz), automatic start| |DC duty|||L1 +, L2 –, L3 nc, PE #| ||||L1 +, L2 nc, L3 –, PE #| |**Output characteristics**|||| |Rated output power||W|240| |Rated output voltage|||24 V DC (± 2%)| |Tolerance|||±2 %| |Setting range for the output voltage|||24 - 28 V DC| |Nominal current||A|10| |Derating from Tamb> +50 °C|||Vertical:| ||||> 50 °C (2.5% / °C)| ||||> 70 °C (5% / °C)| ||||Horizontal:| ||||> 40 °C (2.5% / °C)| ||||> 60 °C (5% / °C)| |Capacitive load starting|||Max 10000 µF| |Heat dissipation||W|26.7| ## **Output characteristics** 05/10/2022 Eaton 172884 ED2022 V91.0 EN 1 / 4 |Efciency||%|> 90 with 3 x 400 V AC & 3 x 500 V AC| |---|---|---|---| |Residual ripple and switching peaks|||< 50 mVpp / < 150 mVpp| |Can be switched in parallel|||for redundancy, with O ring diode (PSG480R24RM/PSG960R24RM)| |**General characteristics**|||| |Housing|||Aluminium| |Status indication|||green LED for "DC OK"| |MTBF (mean time between failures)|||> 300,000 h| |Height||mm|121| |Width||mm|70| |Depth||mm|117.3| |Weight||kg|0.89| |Terminations|||Screw connection| |Stripping length||mm|7| |Terminal capacity|||| |fexible with ferrules/solid||mm2|Primary side: 0.82 - 3.3 mm² (18 - 12 AWG)<br>Secondary side: 1.3 - 3.3 mm² (16 - 12 AWG)| |Tightening torque||Nm|Primary side: 0.9<br>Secondary side: 0.6| |Ambient air temperature range||°C|| |Operation||°C|-25 - +80| |Storage, transport|ϑ|°C|| |Storage|ϑ|°C|-25 - +85| |damp heat|||< 95 % relative humidity at +25 °C, no condensation| |Vibrations (IEC/EN 60068-2-6)|||10 - 500 Hz at 30 m/s² (3 G max ) for 60 min. in X-axis, Y-axis, Z-axis directions| |Mechanical shock resistance (IEC 60068-2-27)|||30 g (300 m/s²) in all directions| |Pollution degree|||2| |Climatic class (IEC)|||3K3 according to EN 60721| |**Safety and safety features**|||| |Transient overvoltage protection|||Varistor| |Current limitation at short-circuit|||IÜberstrom= 150 % der max. Ausgangsleistung| |Overvoltage protection|||Yes, against internal overvoltage| |Insulation voltage|||| |Input/Output|||4 kV AC| |Input/PE|||2 kV AC| |Output/PE|||1.5 kV AC| |Degree of Protection|||IP20| |Protection class|||Class I with PE connection| |**Standards**|||| ||||Electrical equipment of machines: IEC60204-1 (Overvoltage category III)<br>Equipping power installations with electronic apparatus: EN 50178/IEC 62103<br>Safety extra-low voltage: PELV (EN 60204), SELV (EN 60950)<br>Protection against electric shock: DIN 57100-410<br>CE: according to EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU<br>RoHS-compliant: RoHS Directive 2011/65/EU<br>ITE: EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024<br>Industrial: EN 55011<br>Mains harmonics limitation: EN 601000-3-2<br>Electrical Safety (of IT equipment) : SIQ to EN60950-1, UL/c-UL recognized to UL<br>60950-1, CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1<br>UL508<br>Class2: UL/c-UL recognized to UL1310 and CSA C22.2 No. 223 |<br>Component power supply unit for general use: EN61204-3| |Approvals|||EAC| |**Design verifcation asper IEC/EN 61439**|**Design verifcation asper IEC/EN 61439**|**Design verifcation asper IEC/EN 61439**|**Design verifcation asper IEC/EN 61439**| |---|---|---|---| |<br>Technical data for design verifcation|||| |<br>Static heat dissipation, non-current-dependent|Pvs|W|26.7| |Operating ambient temperature min.||°C|-25| |Operating ambient temperature max.||°C|80| |IEC/EN 61439 design verifcation|||| |<br>10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| 05/10/2022 Eaton 172884 ED2022 V91.0 EN 2 / 4 |10.2.3.1 Verifcation of thermal stability of enclosures|||Meets the product standard's requirements.| |---|---|---|---| |<br>10.2.3.2 Verifcation of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |<br>10.2.3.3 Verifcation of resistance of insulating materials to abnormal heat<br>and fre due to internal electric efects|||Meets the product standard's requirements.| |<br>10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Meets the product standard's requirements.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |10.9 Insulation properties|||| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| ## **Technical data ETIM 8.0** Low-voltage industrial components (EG000017) / DC-power supply (EC002540) |**Technical data ETIM 8.0**|**Technical data ETIM 8.0**|**Technical data ETIM 8.0**|**Technical data ETIM 8.0**| |---|---|---|---| |Low-voltage industrial components (EG000017) / DC-power supply (EC002540)|||| |Electric engineering, automation, process control engineering / Power supply devices / Power supply device / Continuous current supply (ecl@ss10.0.1-27-04-07-01 [AFX040003])|||| |Voltage type of supply voltage|||AC| |1st secondary output voltage||V|24 - 24| |2nd secondary output voltage||V|0 - 0| |3rd secondary output voltage||V|0 - 0| |Max. output current 1||A|10| |Max. output current 2||A|0| |Max. output current 3||A|0| |Secondary voltage adjustable|||Yes| |Nominal value output voltage 1||V|24| |Nominal value output voltage 2||V|0| |Nominal value output voltage 3||V|0| |Nominal value output current 1||A|10| |Nominal value output current 2||A|0| |Nominal value output current 3||A|0| |Short-circuit-proof|||Yes| |Rated supply voltage at AC 50 Hz||V|320 - 600| |Rated supply voltage at AC 60 Hz||V|320 - 600| |Rated supply voltage at DC||V|0 - 0| |Output voltage stabilized|||Yes| |Power consumption||VA|300| |Power output||W|240| |Stabilized|||Yes| |Type of electric connection|||Screw connection| |Rail mounting possible|||Yes| |Wall mounting possible|||No| |Modular version|||Yes| |Width in number of modular spacings|||0| |Built-in width||mm|70| 05/10/2022 Eaton 172884 ED2022 V91.0 EN 3 / 4 |Built-in height||mm|121| |---|---|---|---| |Direct mounting possible|||No| |Width||mm|110| |Height||mm|145| |Depth||mm|160| |Suitable for safety functions|||No| |SIL according to IEC 61508|||None| |Performance level according to EN ISO 13849-1|||None| |Degree of protection (IP)|||IP20| |Degree of protection (NEMA)|||1| ## **Dimensions** ## **Additional product information (links)** Product overview WEB) http://www.eaton.eu/psg Eaton Industries GmbH http://www.eaton.eu © 05/2022 by Eaton Industries GmbH Eaton 172884 ED2022 V91.0 EN 05/10/2022 4 / 4
Updated at June 4, 2026
Eaton is a global leader in power management technologies, providing energy-efficient solutions that help customers effectively manage electrical power safely and sustainably. Renowned in the electronics industry for its deep engineering expertise, the company develops reliable components designed to address the most critical power challenges across the computing, industrial, medical, and transportation sectors. The manufacturer's product portfolio is highly regarded for its robust power and line protection solutions. A core focus of their offering includes high-efficiency AC/DC converters designed for demanding power supply applications. Complementing these are Eaton's advanced passive components, particularly power inductors, which play a critical role in energy storage, filtering, and voltage regulation in modern electronic circuitry. Furthermore, their industry-leading circuit protection lineup features precision thermal circuit breakers built to safeguard sensitive equipment from overcurrent events. Beyond power conversion and protection, Eaton supplies specialized components for broader industrial applications. This includes precision panel instrumentation for automation and process control, as well as dependable power relays for complex switching tasks. Through a steadfast commitment to innovation and quality, Eaton equips engineers with the critical components required to build safe, efficient, and resilient electronic systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →