Image not available
Illustrative purposes only
PMT-12V150W1AA
POWER SUPPLY, AC-DC, 12V, 12.5A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Enclosed Power Supplies
- Power Supply Applications:ITE; No. of Outputs:1Outputs; Output Power Max:150W; Output Voltage - Output 1:12V; Output Current - Output 1:12.5A; Output Voltage - Output 52AH7577
- Product Range: PMT Series
- No. of Outputs: 1Outputs
- Output Power Max: 150W
- Input Voltage VAC: 90V AC to 132V AC, 180V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 12.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 30.48 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **PMT** ## **Highlights & Features** - AC input voltage range selectable by switch (90-132Vac, 180-264Vac) - Conforms to harmonic current IEC/EN 61000-3-2, Class A - High MTBF > 700,000 hrs as per Telcordia SR-332 - Versatile configuration options (Enclosed, L Frame) - Versatile connector options (Terminal Block, Front Face, Harness) ## **Safety Standards** CB Certified for worldwide use **Model Number:** PMT-12V150W1A☐ **Unit Weight** : 0.48 kg (1.06 lb) **Dimensions (L x W x D):** 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) ## **General Description** The new PMT series of panel mount power supplies is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. The product offers a wide operating temperature range from -10°C to +70°C and can withstand shock and vibration requirements (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years. This versatile series has three different connector options (Terminal Block, Front Face and Harness) and can also be converted into L Frame (PML) type of power supplies to satisfy different application needs. ## **Model Information** PMT Panel Mount Power Supply |**ModelNumber**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated Output Current**| |---|---|---|---| |PMT-12V150W1A☐|90-132Vac, 180-264Vac<br>(Selectable by Switch)|12Vdc|12.5A| ## **Model Numbering** ||||||||**CC Code****| |---|---|---|---|---|---|---|---| |**PM**|□**–**|**12V**|**150W**|**1**|**A**|□|□| |Panel Mount|Product Type<br>T – Enclosed<br>L – L Frame*|Product Type<br>Output Voltage|Output Power|Single Phase|No PFC|Connector Type<br>A – Terminal Block<br>G – Front Face*<br>H – Harness*|B – With conformal<br>coating| *Options **For Enclosed type with Terminal Block All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 1 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Specifications** Input Ratings / Characteristics |**Specifications**<br>Input Ratings / Characteristics|| |---|---| |Nominal Input Voltage|100-120Vac, 200-240Vac(Selectable bySwitch)| |Input Voltage Range|90-132Vac, 180-264Vac(Selectable bySwitch)| |Nominal Input Frequency|50-60Hz| |Input FrequencyRange|47-63Hz| |Input Current|< 3.00A @ 115Vac, < 2.00A @ 230Vac| |Efficiencyat 100% Load|> 86.0%@230Vac| |Max Inrush Current(Cold Start)|< 45A@230Vac| |Leakage Current|< 0.5mA@240Vac| Output Ratings / Characteristics* |Output Ratings / Characteristics*|| |---|---| |Nominal Output Voltage|12Vdc| |FactorySet Point Tolerance|12 Vdc ± 1%| |Output Voltage Adjustment Range|11.4-13.5Vdc| |Output Current|12.5A(150W max.)| |Output Power|150W| |Line Regulation|± 0.5% typ.(@100-132Vac & 200-264Vac)| |Load Regulation|± 0.5% typ.(@100-132Vac & 200-264Vac)| |PARD**(20MHz)|< 120mVpp| |Rise Time|< 30ms@115Vac, < 20ms@230Vac(100% load)| |Start-up Time|< 1200ms @ 115Vac, < 800ms @ 230Vac (100% load)| |Hold-up Time|> 20ms@115Vac, > 24ms@230Vac(100% load)| |Dynamic Response (Overshoot & Undershoot O/P Voltage)|± 5% @ 0-100% load| |Start-upwith Capacitive Loads|8,000µF Max| *For power de-rating from 50°C to 70°C, see power de-rating on page 3. **PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 2 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## Mechanical |Mechanical||| |---|---|---| |Case Chassis / Cover||Aluminium / SGCC| |Dimensions (L x W x D)||178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch)| |Unit Weight||0.48 kg (1.06 lb)| |Indicator||Green LED(DC OK)| |CoolingSystem||Convection| |Terminal|PM☐-12V150W1AA☐|M3.5 x 7 Pins(Rated 300V/15A)| ||PM☐-12V150W1AG|M3.5 x 7 Pins (Rated 300V/20A)| ||PM☐-12V150W1AH|I/P (JWT): A3963WV2-5P-A<br>O/P(JWT): A3963WV2-7P-U| |Wire|PM☐-12V150W1AA☐|AWG 18-12| ||PM☐-12V150W1AG|| ||PM☐-12V150W1AH|AWG 18 (For the recommended Mating Connector and<br>Terminal, please refer to the Table on Page 8)| |Noise(1 Meter frompower supply)||Sound Pressure Level(SPL)< 25dBA| ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating|-10°C to +70°C| ||Storage|-25°C to +85°C| |Power De-rating||> 50°C de-rate power by 2.5% / °C<br><100Vac de-rate power by 3% / 1V| |OperatingHumidity||5 to 95% RH(Non-Condensing)| |OperatingAltitude||0 to 5,000 Meters(16,400 ft.)| |Shock Test|Non-Operating|IEC 60068-2-27, Half Sine: 50G for a duration of 11ms,<br>3 times per direction, 18 times in total| |Vibration|Non-Operating|IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms,<br>20 min per axis for all X, Y, Z direction| |Over Voltage Category||II| |Pollution Degree||2| ## Protections |Protections|| |---|---| |Overvoltage|115-135%, Hiccup Mode, Non-Latching<br>(Auto-Recovery)| |Overload / Overcurrent|110-150%, Hiccup Mode, Non-Latching<br>(Auto-Recovery)| |Over Temperature|< 70°C Surrounding Air Temperature @ 100% load, Non-<br>Latching (Auto-Recovery)| |Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-Recoverywhen the fault is removed)| |Internal Fuse at L pin|T5AH| |Protection Against Shock|Class I with PE* connection| *PE: Primary Earth **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 3 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## Reliability Data |Reliability Data||| |---|---|---| |MTBF||> 700,000 hrs as per Telcordia SR-332<br>I/P: 100Vac, O/P: 100% load, Ta: 35°C| |Expected Cap Life Time||10years(115Vac & 230Vac, 50% load@40°C)| ## Safety Standards / Directives |Safety Standards / Directives||| |---|---|---| |SafetyEntryLow Voltage||SELV(EN 60950-1)| |Electrical Safety|TUV Bauart<br>UL/cUL recognized<br>CB scheme<br>CCC|EN 60950-1<br>UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)<br>IEC 60950-1<br>GB4943| |CE||In conformance with EMC Directive 2014/30/EU and<br>Low Voltage Directive 2014/35/EU| |Material and Parts||RoHS Directive 2011/65/EU Compliant| |Galvanic Isolation|Input to Output|3.0KVac| ||Input to Ground|1.5KVac| ||Output to Ground|0.5KVac| ## EMC |EMC||| |---|---|---| |Emissions(CE & RE)||CISPR 32, EN 55032, FCC Title 47: Class B| |Immunity||| |Electrostatic Discharge|IEC 61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV| |Radiated Field|IEC 61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation| |Electrical Fast Transient / Burst|IEC 61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge|IEC 61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Conducted|IEC 61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms| |Power Frequency Magnetic Fields|IEC 61000-4-8|Criteria A1)<br>10A/Meter| |Voltage Dips and Interruptions|IEC 61000-4-11|100% dip; 1 cycle (20ms); Self Recoverable| |Low Energy Pulse Test (Ring Wave)|IEC61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Harmonic Current Emission||IEC/EN 61000-3-2, Class A| |Voltage Fluctuation and Flicker||IEC/EN 61000-3-3| 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 4 **www.DeltaPSU.com (November 2018, Rev. 03)** ## **TECHNICAL DATASHEET PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Block Diagram** ## **Device Description** **PMT-12V150W1AA** ~~-~~ ☐ **:** Terminal Block **PMT-12V150W1AG:** Front Face ; COBO ~~OR~~ ERO ~~ROO ERB~~ GN Ne: Side surface Pesceraceasccessnc t oO Eorccorccccncdnedsar8 5 CO ele. 004 eX A\ . C@CS2R62<SEBO esa erccercceeePOCPROOR Es LAGEA\ ZOOSZOECCOSRLOO.sFOCSZSPPOBSOr O28 QO, S Stra)NeeDFx e) Or ep<x<> } CEPOBEP COEF OOERO N SECO OS (2) OBLOBZESRPOOCLOOPRO Top surface Steep cs Ke: PPEOOPRBOSROOCPOCPPOS ESN \ See Recercccecceeecceessencne) e ODBPEROSPOCEO CREO CREO OR R **O** N Ne ® ODORSCOEFROOKCORRCOCRCOOKCORRCOELCOOKECORRCOEFOOZCOER®COFCOCOEZLO OC. OO6LEOOAL COB?COOKCORRCORKCORROCOEKCORROEOFS **PMT-12V150W1AH:** ~~—~~ Harness - 1) Input & Output terminal block connector - 2) DC voltage adjustment potentiometer 3) DC OK control LED (Green) - 4) AC selectable switch All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 5 ## **TECHNICAL DATASHEET PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Dimensions** **L x W x D:** 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 6 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. **Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation** > 50°C de-rate power by 2.5% / °C 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm (0.79 inch) with adjacent units while the device is in operation. 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please contact **info@deltapsu.com** for more details. ## Output Load De-rating VS Input Voltage - No output power de-rating for the input voltage from 100Vac to 132Vac & 200Vac to 264Vac All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 7 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Assembly & Installation** Mounting holes for power supply assembly onto the mounting surface. - Ⓐ The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm (0.20 inch) length. Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted. Ⓒ Connector |Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted.This surface belongs to customer’s end system or panel where the power supply is mounted.<br>Ⓒ ConnectorConnector|Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted.This surface belongs to customer’s end system or panel where the power supply is mounted.|Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted.This surface belongs to customer’s end system or panel where the power supply is mounted.| |---|---|---| |**Side Mounting (Vertical)**|**Base Mounting (Vertical)**|**Side Mounting (Horizontal)**| |ike<br>@<br>©)|@) |ee|| hrpepperreeegsL| |**Fig. 2**<br>**Recommended Mounting Orientations**||| - **PM** ☐ **-12V150W1AA** ☐ **/ PM** ☐ **-12V150W1AG:** Use flexible cable (stranded or solid) of AWG No. 18-12. The torque at the connector shall not exceed 13Kgf.cm (11.23 lbf.in). The insulation stripping length should not exceed 0.275” or 7mm. - • **PM** ☐ **-12V150W1AH:** Please refer the table below for the recommended mating connector, terminal and AWG wire size. ||**Header (Board Mounting)**|**Mating Connector**|**Terminal**|**AWG**| |---|---|---|---|---| |**Input (JWT)**|A3963WV2-5P-A|A3963H02-5P|A3963T0P-2|18| |**Output (JWT)**|A3963WV2-7P-U|A3963H02-7P||| ## Installation of Mounting Accessories **Fig. 3 Assembly Reference** With reference to Fig. 3, the device should be mounted on a sturdy heat conducting surface with minimum of 4 mounting holes using M3 screw through the base or side mounting holes. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 8 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ - - Only use M3 screw ≤ 4.0 mm (0.16 inch) through the base and side mounting holes. This is to keep a safe distance between the screw and internal components. - Recommended mounting tightening torque: 4~7Kgf.cm. (3.47~6.08 lbf.in). ## **Fig. 4 Mounting Screw** ## Safety Instructions - Must select correct AC input voltage before turning on (Refer to the “Device Description” on Page 5). - If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information. - To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm (0.79 inch) from all ventilated surfaces while the device is in operation. - The device is not recommended to be placed on low thermal conductive surfaces, for example, plastics. - The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause electric shock, safety hazard, fire and/or product failure. - The power supply must be mounted by metal screws onto a grounded metal surface. It is also highly recommended that the Earth terminal on the connector be connected to the grounded metal surface. - Warning (For Standard Terminal Block and Front Face Terminal Block products): When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. **==> picture [63 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories<br>**----- End of picture text -----**<br> ## L-02: Latch ## P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 9 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Functions** ## Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ## ■ **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. ## Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. ## **50% duty cycle / 5Hz to 1KHz** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 10 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 110150% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection (Auto-Recovery) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. ## Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is <110-150% but >100%, since it may cause damage to the PSU. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the derating graph. ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 11 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 12V 150W 1 Phase / PMT-12V150W1A □ ## **Others** ## Delta RoHS Compliant ## **Restriction of the usage of hazardous substances** **==> picture [43 x 46] intentionally omitted <==** The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. ## PFC – Norm EN 61000-3-2 ## **Line Current Harmonic content** Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 03)** 12
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →