PMC01D115
MULTIFUNCTION TIMER
- Manufacturer: CARLO GAVAZZI
- Product type: Analogue Timers
- Product Range:PMC01 Series; Timer Functions:Multifunction; No. of Timing Ranges:7Ranges; Time Min:0.1s; Time Max:100h; Timer Output:2 Changeover Relays; Supply Voltage Max:115VAC; C
- No. of Timing Ranges: 7Ranges
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 216.14 € |
| Current stock | 10+ |
| Lead time | 22 days |
## **Timers Multifunction** ## **Types DMC01, PMC01** - **Time range 0.1 s to 100 h** **==> picture [239 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> DMC01C DMC01D PMC01<br>ov<br>**----- End of picture text -----**<br> - **7 knob selectable functions Op - Delay on operate, manual start Oa - Delay on operate, automatic and manual start In - Interval, manual start Ia - Interval, automatic and manual start Nr - Interval with no time reset, manual start Na - Interval with no time reset, automatic and manual start** - **Dr - Delay on release** - **Knob selection of time range** - **Knob adjustable time setting** - **External adjustable time setting available** - **Repeatability:** ≤ **0.2%** - **DC supply for PNP/NPN and Namur sensors** - **Output: 8 A SPDT or 2 x 8 A SPDT relay** - **For mounting on DIN-rail in accordance with DIN/EN 50 022 or Plug-in** - **22.5 mm or 45 mm Euronorm or 36 mm Plug-in module housing** - **LED indication for relay status and power supply ON** ## **Product Descri tion p** 15 VDC, 10 mA (1 relay) or 24 VDC, 15 mA (2 relays) supply for PNP/NPN sensors and 8.2 VDC supply for Namur sensor. For mounting on DIN-rail (DMC01) or Plug-in (PMC01). Multi-voltage timer with 7 knob selectable functions and 7 knob selectable time ranges within 0.1s and 100h. Remote time setting available. **Ordering key DMC 01 C B23** **Housing Function Type Item number Output Power Supply** ~~———s~~ ## **T e Selection yp** **Mounting Output Housing Supply: 24 VDC Supply: 24 or 48 VAC Supply: 115 or 230 VAC** For DIN-rail 1 x SPDT D - 22.5 mm **DMC 01 C 724 DMC 01 C B48 DMC 01 C B23** For DIN-rail 2 x SPDT D - 45 mm **DMC 01 D 724 DMC 01 D B48 DMC 01 D B23 Mounting Output Housing Supply: 24 VDC Supply: 24 VAC Supply: 115 VAC Supply: 230 VAC** Plug-in 1 x SPDT P - Housing **PMC 01 C 724 PMC 01 C 024 PMC 01 C 115 PMC 01 C 230** Plug-in 2 x SPDT P - Housing **PMC 01 D 724 PMC 01 D 024 PMC 01 D 115 PMC 01 D 230** ## **Time S ecifications p** **Time ranges** Knob selectable 0.1 to 1 s 1 to 10 s 6 to 60 s 60 to 600 s 0.1 to 1 h 1 to 10 h 10 to 100 h **Setting accuracy** ≤ 5% **Repeatability** ≤ 0.2% **Time variation** Within rated power supply ≤ 0.05%/V Within ambient temperature ≤ 0.2%/°C **External time setting** Linear remote potentiometer 10 kΩ Max length of pot. cable 3 m ## **Reset** Manual reset of time and/or relay Pulse duration Power supply interruption - 1 relay versions: - 2 relays versions: - **PNP/NPN sensor supply output** 1 relay versions: - 2 relays versions: **Namur sensor connection** Close the trigger contact ≥ 10 ms - ≥ 700 ms ≥ 200 ms 15 VDC, 10 mA 24 VDC, 15 mA pins + and - or 6 and 7 pin + or 6 positive 8.2 VDC, 1kΩ pins + and S or 6 and 5 pin + or 6 positive **1** Specifications are subject to change without notice (18.06.07) **DMC01, PMC01** ## **Out ut S ecifications p p** |**Output**||1 or 2 x SPDT relay|| |---|---|---|---| |**Rated insulation voltage**<br>**Contact Ratings**(AgSnO2)<br>Resistive loads<br>AC 1||250 VAC(RMS)<br>µ<br>8 A @ 250 VAC|| ||DC 12|5 A @ 24 VDC|| |Small inductive loads|AC 15|2.5 A @ 250 VAC|| ||DC 13|2.5 A @ 24 VDC|| |**Mechanical life**<br>**Electrical life**<br>**Operating frequency**||≥30 x 106 operations<br>≥105 operations<br>(at 8 A,250 V,cosϕ= 1<br>< 7200 operations / h|= 1)| |**Dielectric strength**|||| |Dielectric voltage||2 kVAC (RMS)|| |Rated impulse withstand volt.||4 kV (1.2/50 µs)|| ## **Su l S ecifications pp y p** |**Power supply**|Overvoltage cat. III| |---|---| |Rated operational voltage|(IEC 60664, IEC 60038)| |through terminals:<br>A1, A2 or A1, A3 (DMC01)<br>B48|24 or 48 VAC ± 15%| |B23|45 to 65 Hz<br>115 or 230 VAC ± 15%| ||45 to 65 Hz| |724|24 VDC ± 20%| |2, 10 (PMC01)|| |024|24 VAC ± 15%,45 to 65 Hz| |115<br>230|115 VAC ± 15%,45 to 65 Hz<br>230 VAC ± 15%,45 to 65 Hz| |724|24 VDC ± 20%| |**Voltage interruption**|≤10 ms| |**Rated operational power**|| ## **General S ecifications p** |**Power ON delay**||≤100 ms| |---|---|---| |**Reaction time from trigger**||| |Delayed contact(s)||< 10 ms| |Instantaneous contcat||< 20 ms| |**Indication for**||| |Power supply ON||LED, green| |Output relays ON||LED, yellow (flashing when| |||timing)| |**Environment**||(EN 60529)| |Degree of protection||IP 20| |Pollution degree||3 (DMC01), 2 (PMC01)| |||(IEC 60664)| |Operating temperature||-20 to 60 °C, R.H. < 95%| |Storage temperature||-30 to 80 °C,R.H. < 95%| |**Housing**||| |Dimensions|DMC01C|22.5 x 80 x 99.5 mm| ||DMC01D<br>PMC01|45 x 80 x 99.5 mm<br>36 x 80 x 94 mm| |**Weight**||120 to 260g depending on| |||model| |**Screw terminals**||(DMC01)| |Tightening torque||Max 0.5 Nm according to| |||IEC EN 60947| |**Approval**||UL,CSA| |**CE Marking**||Yes| |**EMC**||Electromagnetic Compatibility| |Immunity||According to EN 61000-6-2| |Emission||Accordingto EN 61000-6-3| |**Timer Specifications**||According to EN 61812-1| AC supply: 5 VA DC supply: 2 W ## **Function/Range/Time Setting** Adjust the function setting the DIP switches 1 to 6 as shown below (1 to 4 for DMC01Cxxx). In - Interval, manual start Ia - Interval, automatic and manual start To access the DIP switches open the grey plastic cover using a screwdriver as shown below. scale: 1 to 10 with respect to the chosen range. ## **Lower knob:** - Nr - Interval with no time reset, manual start Setting of time range **Note 1:** DIP switch 5 must be kept ON when using PMC01Dxxx. ## **Upper knob:** **External potentiometer** Na - Interval with no time reset, automatic and manual start Selection of function: **(DMC01D, PMC01C):** Time setting on relative scale: 1 to 10 with respect to the chosen range. Op - Delay on operate, manual start **Note 2:** DIP switch 6 does not have any effect on the PMC01Cxxx working mode. Dr - Delay on release Oa - Delay on operate, automatic and manual start **Centre knob:** Time setting on relative **Sensor type selection** **DMC01D, PMC01C, PMC01D** **PMC01C,** ON ON OFF OFF: PNP/NPN sensor, **PMC01D** ~~7~~ Open collectoror contact ~~_~~ —_ **DMC01C** OFF OFF ON ON: Namur sensor **Time setting (DMC01D and PMC01C)** ON: Centre knob on front OFF: External trimmer **Second relay** ON: Instantaneous OFF: DPDT ~~e~~ e ~~s~~ **2** Specifications are subject to change without notice (18.06.07) **DMC01, PMC01** ## **Mode of O eration p** ## **Function Op: Delay on operate, manual start** ## **Function Ia: Interval, automatic and manual start** ## **Function Dr: Delay on release** The time period begins as The relay operates and the soon as the trigger contact time period begins as soon is closed. as the power supply is connected. The relay operates as soon as the trigger contact is closed. The time period begins when the trigger contact is opened. The relay releases at the end of the set delay time or when the power supply is disconnected. The relay operates again when the input contact is closed again. If it is closed before the end of the delay time the relay keeps ON, a new time period begins as soon as the contact is opened again. At the end of the set delay nected. time the relay operates and The relay releases at the end doesn't release until the trigof this period or when the ger contact is closed again power supply is disconnector the power supply is dised. The relay operates again connected. When the trigger when the trigger contact is contact is closed, the relay closed. If the trigger contact releases and a new time is closed before the end of period starts. the delay time, the relay keeps ON and a new time period starts. ## **Function Oa: Delay on operate, automatic and manual start** ## **Function Nr: Interval with no time reset, manual start** The time period begins as **Example1: Delay on** soon as the power supply is The relay operates and the **operate with remote** connected. time period begins as soon **control time setting:** At the end of the set delay as the trigger contact is time the relay operates and closed. The relay releases at Using the delay on operate doesn't release until the trigthe end of this period or function, DMC01D or ger contact is closed or the when the power supply is PMC01C can be used to set power supply is disconnectdisconnected. The relay the working delay of an ed. When the trigger contact operates again when the equipment (i.e. a pump) by a is closed, the relay releases trigger contact is closed knob placed on a panel. It is and a new time period again. only necessary to connect starts. an external potentiometer to the suitable pins (T1, T2, T3 **Function Na: Interval with** for DMC01D or 8. 9. 11 for **Function In: Interval, no time reset, automatic** PMC01C) and mount the **manual start and manual start** knob on the control panel. The relay operates and the The relay operates and the time period begins as soon time period begins as soon as the trigger contact is as the power supply is conclosed. The relay releases at nected. the end of this period or The relay releases at the end when the power supply is of this period or when the disconnected. The relay power supply is disconnectoperates again when the ed. The relay operates again trigger contact is closed when the trigger contact is again. If the trigger contact closed. is closed before the end of the delay time, the relay keeps ON and a new time period starts. ## **Note:** The external potentiometer must be connected before the product operates. The cable length must be below 3 m ## **Example 2: Interval with NPN or Namur proximity sensor.** Using the Interval function and a NPN or Namur proximity sensor, DMC01 and PMC01 can be used to monitor the actual presence of an object (i.e. a can) in the right place on a convejor belt. In fact the sensor triggers the timer each time it detects an object on the belt, so the relay keeps ON as long as there is no gap on the belt. As soon as there is a gap on the belt, the relay switches OFF and an alarm can be activated. ## **Yellow LED working mode** Timing: Slow blinking Relay ON: See operation diagrams Incorrect knobs position: Fast blinking **3** Specifications are subject to change without notice (18.06.07) **DMC01, PMC01** ## **O eration Dia rams p g** **Function Op - Delay on operate, manual start Function Oa - Delay on operate, automatic and manual start Power supply Power supply Trigger input Trigger input** ON ON **Relay 1 ON Relay 1 ON** OFF OFF **Relay 2 ON** ON **Relay 2 ON** ON **(delayed) (delayed)** OFF OFF **Relay 2 ON** ON **Relay 2 ON** ON **(instant.) (instant.)** OFF OFF **LED LED** **Function In - Interval, manual start** |**Power supply**||||||||| |---|---|---|---|---|---|---|---|---| |||||||||| |**Trigger input**||||||||| |ON||||||||| |**Relay 1 ON**<br>||||||||| |OFF||||||||| |**Relay 2 ON**<br>**(delayed)**<br>ON||||||||| |||||||||| |OFF||||||||| |**Relay 2 ON**<br>**(instant.)**<br>ON<br>||||||||| |||||||||| |OFF||||||||| |**LED**||||||||| **Function Ia - Interval, automatic and manual start** |**Power supply**|||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**Trigger input**|||||||||||||||| |**Trigger input**|||||||||||||||| |**Relay 1 ON**<br>ON|||||||||||||||| |**Relay 2 ON**<br>**(delayed)**<br>ON<br>OFF|||||||||||||||| |**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF|||||||||||||||| |**LED**<br>OFF|||||||||||||||| |**LED**|||||||||||||||| **Function Nr - Interval with no time reset, manual start** |**Power supply**|||||||| |---|---|---|---|---|---|---|---| |**Trigger input**|||||||| ||||||||| |**Relay 1 ON**<br>ON|||||||| ||||||||| |OFF|||||||| |**Relay 2 ON**<br>**(delayed)**<br>ON|||||||| ||||||||| |**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF|||||||| ||||||||| |OFF|||||||| |**LED**|||||||| **Function Na - Interval with no time reset, automatic and manual start** **Power supply Trigger input** ON **Relay 1 ON** OFF **Relay 2 ON (delayed)** ON OFF **Relay 2 ON (instant.)** ON OFF **LED** |**Function Dr - Delay on release**<br>**Power supply**<br>**Trigger input**<br>**Relay 1 ON**<br>**LED**<br>**Relay 2 ON**<br>**(delayed)**<br>**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF|**Function Dr - Delay on release**<br>**Power supply**<br>**Trigger input**<br>**Relay 1 ON**<br>**LED**<br>**Relay 2 ON**<br>**(delayed)**<br>**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF|**Function Dr - Delay on release**<br>**Power supply**<br>**Trigger input**<br>**Relay 1 ON**<br>**LED**<br>**Relay 2 ON**<br>**(delayed)**<br>**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF|**Function Dr - Delay on release**<br>**Power supply**<br>**Trigger input**<br>**Relay 1 ON**<br>**LED**<br>**Relay 2 ON**<br>**(delayed)**<br>**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF| |---|---|---|---| |**Power supply**|||| |**Trigger input**|||| ||||| |**Relay 1 ON**<br>ON|||| ||||| |**Relay 2 ON**<br>**(delayed)**<br>ON<br>OFF|||| ||||| |**Relay 2 ON**<br>**(instant.)**<br>ON<br>OFF|||| ||||| |**LED**<br>OFF|||| ||||| ||||| **4** Specifications are subject to change without notice (18.06.07) **DMC01, PMC01** ## **Wiring Diagrams** **==> picture [501 x 296] intentionally omitted <==** **----- Start of picture text -----**<br> DMC01C - Contact input PMC01C - Contact input<br>DMC01C - Open collector input PMC01C - Open collector input<br>**----- End of picture text -----**<br> **==> picture [245 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> DMC01D - PNP / NPN sensor input<br>**----- End of picture text -----**<br> **==> picture [245 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> DMC01D - Namur sensor input<br>**----- End of picture text -----**<br> **==> picture [245 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> PMC01D - PNP / NPN sensor input<br>**----- End of picture text -----**<br> **==> picture [245 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> PMC01D - Namur sensor input<br>**----- End of picture text -----**<br> **5** Specifications are subject to change without notice (18.06.07) **DMC01, PMC01** ## **Dimensions** **==> picture [244 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> DIN-rail<br>22.5<br>99.5<br>28.5<br>80 83.5 63<br>**----- End of picture text -----**<br> **==> picture [245 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> DIN-rail<br>45 99.5<br>28.5<br>80 83.5 63<br>**----- End of picture text -----**<br> **==> picture [244 x 180] intentionally omitted <==** **----- Start of picture text -----**<br> Plug-in<br>94<br>36 90<br>28.5<br>80 63<br>**----- End of picture text -----**<br> **6** Specifications are subject to change without notice (18.06.07)
Updated at April 29, 2026
Founded in Milan in 1931, Carlo Gavazzi is a globally recognized leader in the design and manufacture of high-quality automation components. For nearly a century, the company has driven technological innovation in the industrial and building automation markets. With ISO 9001-certified production facilities across Europe and Asia, Carlo Gavazzi delivers state-of-the-art solutions tailored for demanding applications, including HVAC, renewable energy, semiconductor manufacturing, and electric vehicle charging infrastructure. Our extensive portfolio of Carlo Gavazzi components focuses heavily on their industry-leading switching and sensing technologies. We carry a comprehensive selection of solid state relays, contactors, and power relays engineered for exceptional reliability and thermal performance. Alongside these robust switching solutions, our range features a wide array of precision sensors, with a strong emphasis on proximity switches and light sensors that are critical for automated manufacturing processes, mobile equipment, and access control systems. Beyond core sensing and switching, the Carlo Gavazzi lineup extends into essential power management, circuit protection, and control devices. This includes highly efficient AC/DC converters, thermal magnetic circuit breakers, and advanced panel instrumentation designed to monitor and optimize energy efficiency. From current sensing transformers to motor starters, engineers consistently trust Carlo Gavazzi to provide competitive, dependable, and forward-thinking components for their most complex automation challenges.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →