- Manufacturer: NIDEC COPAL ELECTRONICS
- Product type: Pressure Transducers
- Port Style: Tube
- Product Range: P-2000 Series
- Sensor Output: Analogue
- Supply Current: 1.5mA
- Operating Pressure Max: 49kPa
- Pressure Measurement Type: Gauge
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 16.06 € |
| Current stock | 10+ |
| Lead time | 7 days |
## PRESSURE TRANSDUCERS
## **- P 2000**
**==> picture [135 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
INTERNAL STRUCTURE (BN type)<br>**----- End of picture text -----**<br>
## ■ **FEATURES**
- Compact and light weight
- For non-corrosive gases
- Dual in line package
- Pressure range ~9.81, ~981 kPa {~0.1, ~10 kgf/cm[2] }
**==> picture [240 x 231] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>3<br>2<br>4 5<br>Part name Material<br>ee<br>1 Housing LCP (Liquid crystal polymer)<br>i ee<br>2 Cover Aluminum<br>ee<br>3 Sensor chip Silicone<br>ee<br>4 Chip resistor (compensatory resistor) Ceramic<br>ee eee<br>5 Terminal pin Phosphor bronze + Au-plated<br>ee<br>**----- End of picture text -----**<br>
## ■ **MODEL NUMBER DESIGNATION**
- P 2000 - 501 G - 15 - BN
|Series name<br>Rated pressure range<br>101:0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2}<br>501:0 ~ 49.0 kPa {0 ~ 0.5 kgf/cm2}<br>102:0 ~ 98.1 kPa {0 ~ 1 kgf/cm2}<br>352:0 ~ 343 kPa {0 ~ 3.5 kgf/cm2}<br>502:0 ~ 490 kPa {0 ~ 5 kgf/cm2}<br>702:0 ~ 686 kPa {0 ~ 7 kgf/cm2}<br>103:0 ~ 981 kPa {0 ~ 10 kgf/cm2}<br>~~—— ~~|Series name<br>Rated pressure range<br>101:0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2}<br>501:0 ~ 49.0 kPa {0 ~ 0.5 kgf/cm2}<br>102:0 ~ 98.1 kPa {0 ~ 1 kgf/cm2}<br>352:0 ~ 343 kPa {0 ~ 3.5 kgf/cm2}<br>502:0 ~ 490 kPa {0 ~ 5 kgf/cm2}<br>702:0 ~ 686 kPa {0 ~ 7 kgf/cm2}<br>103:0 ~ 981 kPa {0 ~ 10 kgf/cm2}<br>~~—— ~~||||Terminal direction<br>AN:Same direction as the pressure port<br>BN:Opposite direction to the pressure port<br>Thermal error<br>15:±0.15 % (±0.12 %) F.S./°C<br>Pressure reference<br> ~~|~~|Terminal direction<br>AN:Same direction as the pressure port<br>BN:Opposite direction to the pressure port<br>Thermal error<br>15:±0.15 % (±0.12 %) F.S./°C<br>Pressure reference<br> ~~|~~|Terminal direction<br>AN:Same direction as the pressure port<br>BN:Opposite direction to the pressure port<br>Thermal error<br>15:±0.15 % (±0.12 %) F.S./°C<br>Pressure reference<br> ~~|~~|Terminal direction<br>AN:Same direction as the pressure port<br>BN:Opposite direction to the pressure port<br>Thermal error<br>15:±0.15 % (±0.12 %) F.S./°C<br>Pressure reference<br> ~~|~~|Terminal direction<br>AN:Same direction as the pressure port<br>BN:Opposite direction to the pressure port<br>Thermal error<br>15:±0.15 % (±0.12 %) F.S./°C<br>Pressure reference<br> ~~|~~|Terminal direction<br>AN:Same direction as the pressure port<br>BN:Opposite direction to the pressure port<br>Thermal error<br>15:±0.15 % (±0.12 %) F.S./°C<br>Pressure reference<br> ~~|~~|
|---|---|---|---|---|---|---|---|---|---|---|
||||||||||G:Gauge||
|■**LIST OF MODEL NUMBERS**|**LIST OF MODEL NUMBERS**||||||||||
|**Terminal**|**Rated pressure range**<br>**0 ~ 9.81**||**0 ~ 49.0**|**0 ~ 98.1**|||**0 ~ 343**|**0 ~ 343**|**0 ~ 490**<br>**0 ~ 686**|**0 ~ 981**|
|**direction**|**kPa {kgf/cm2}**<br>**{0 ~ 0.1}**||**{0 ~ 0.5}**||**{0 ~ 1}**|**{0 ~ 1}**|**{0 ~ 3.5}**|**{0 ~ 3.5}**|**{0 ~ 5}**<br>**{0 ~ 7}**|**{0 ~ 10}**|
||**AN**<br> AP-2000-101G-15-AN|AP-2000-501G-15-AN|P-2000-501G-15-AN|AP-2000-102G-15-AN|||AP-2000-352G-15-AN||AP-2000-502G-15-ANAP-2000-702G-15-AN|AP-2000-103G-15-AN|
||**BN**<br>P-2000-101G-15-BN|P-2000-501G-15-BN||P-2000-102G-15-BN|||P-2000-352G-15-BN||P-2000-502G-15-BN<br>P-2000-702G-15-BN|P-2000-103G-15-BN|
## ■ **LIST OF MODEL NUMBERS**
※ Verify the above model numbers when placing orders.
The AN version, marked A is manufactured upon receipt of order basis.
## **P-2000** PRESSURE TRANSDUCERS
## ■ **STANDARD SPECIFICATIONS**
● Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation current of 1.5 mA DC.
||**Item**<br>**Model number**|**Item**<br>**Model number**|**P-2000**|**P-2000**|**P-2000**|**P-2000**|**P-2000**|**P-2000**|**P-2000**|
|---|---|---|---|---|---|---|---|---|---|
||||**101G**|**501G**|**102G**|**352G**|**502G**|**702G**|**103G**|
|**General specifications**|Pressure reference||Gauge|||||||
||Rated pressure range<br>kPa {kgf/cm2}||9.81<br>{0.1}|49.0<br>{0.5}|98.1<br>{1.0}|343<br>{3.5}|490<br>{5}|686<br>{7}|981<br>{10.0}|
||Maximum pressure<br>kPa {kgf/cm2}||19.6<br>{0.2}|98.1<br>{1.0}|196<br>{2.0}|686<br>{7.0}|981<br>{10}|1373<br>{14}|1471<br>{15.0}|
||Break-down pressure<br>kPa {kgf/cm2}||49.0<br>{0.5}|245<br>{2.5}|490<br>{5}|1030<br>{10.5}|1471<br>{15}|1961<br>{20}|1961<br>{20}|
||Operating temp. range<br>°C||−20 ~ 80|||||||
||Compensated temp. range<br>°C||0 ~ 50|||||||
||Operating humidity|%RH|35 ~ 85(No condensation)|||||||
||Storage temp.|°C|−20 ~ 80(Atmospheric pressure, humidity 65 %RH maximum)|||||||
||Bridge resistance|Ω|3300±30 %|||||||
||Pressure medium||Non-corrosive gases|||||||
||Insulation resistance|MΩ<br>minimum|100 (500 V DC)|||||||
||Dielectric strength||500 V AC, 60 s(Leakage current 1 mA maximum)|||||||
||Pressure port|mm|φ3.2|||||||
||Net weight|g|Approx. 1|||||||
|**Power**|Excitation current|mA DC|1.5(Constant current)|||||||
|**Analog output**|Offset voltage|mV|±20|±15||||||
||Span voltage|mV|50±20|90±30||||||
||Linearity/Hysteresis|%F.S.|±0.3|||||||
||Thermal error<br>(Reference temp.: 25 °C)|ZERO %F.S./°C|±0.15|±0.12||||||
|||SPAN %F.S./°C|±0.05|±0.04||||||
||Response|ms|Approx. 1|||||||
## ■ **ENVIRONMENTAL CHARACTERISTICS**
|**Test item**|**Test conditions (At 25**±**5 °C)**|**Permissible change**|
|---|---|---|
|Vibration|10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2,<br>3 directions for 2 hours each|Offset voltage/Span voltage:<br>±1 %F.S. maximum each|
|Shock|981 m/s2, 3 directions for 3 times each||
|Pressure cycling|0 ~ Rated pressure, 106cycles||
|Moisture resistance|40 °C, 90 ~ 95 %RH, 240 hrs.||
※ **P-2000 series can be operated at the vacuum pressure.**
**P-2000** PRESSURE TRANSDUCERS
## ■ **OUTLINE DIMENSIONS**
Unless otherwise specified, tolerance : ± 0.3 (Unit: mm)
## **BN type**
**==> picture [472 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pressure port R1<br>φ1.2<br>Vent hole<br>12 7.3 5.2 3 ± 0.5 Pressure range marking<br>3.5 ± 0.5<br>Vent hole<br>Pressure range marking 5.2 7.3 12<br>Pressure port<br>φ1.2<br>t = 0.3)(0.5 2.5<br>3 4<br>G<br>10 2 5<br>1 6 +0.1 0 PRESSURE TRANSDUCER P-2000 COPAL JAPAN<br>3.2 2.5<br>φ<br>)t = 0.3(0.5 2.5<br>G 3 4<br>10 2 5<br>PRESSURE P-2000 1 6<br>TRANSDUCER COPAL JAPAN +0.1 0<br>3.2 2.5<br>φ<br>**----- End of picture text -----**<br>
## **AN type**
## ■ **INTERNAL ELECTRICAL SCHEMATICS**
## ■ **TERMINAL NUMBER**
**==> picture [97 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 2 (+)<br>4 1<br>R<br>5 3 (–)<br>(+) (–)<br>Output<br>Input<br>**----- End of picture text -----**<br>
|**Pin**|**Connection**|
|---|---|
|1<br>2<br>3<br>4<br>5<br>6|OutputC|
||InputB|
||InputC|
||OutputB|
||InputC|
||InputB|
R : Built-in chip resistor for temp. compensation
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →