Image not available
Illustrative purposes only
NHXS1C20
Circuit Breaker, 240 V, 20 A, 2 Pole
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: WYLEX
- Product type: RCBO, RCD, GFCI, AFDD Circuit Breakers
- No. of Poles: 2 Pole
- Current Rating: 20A
- Voltage Rating VAC: 240V
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 33.7 € |
| Current stock | 10+ |
| Lead time | 7 days |
## Miniature ## RCBOs & MCBs (for domestic household premises & similar installations) NHX & NHXL Devices ## **WYLEX MINIATURE RCBOs** A range of MCB sized RCBOs for use in domestic household premises and similar installations. Wylex miniature RCBOs bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard and bring cost savings by reducing installation and testing times. ## **Safer installations means safer homes** Wylex Miniature RCBOs with switched neutral built in as standard will fully isolate a faulty or damaged circuit by disconnecting live and neutral conductors. Using Wylex Miniature RCBOs will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off. This avoids danger and prevents inconvenience in the event of a ***** fault (as required by regulation 314.1) . Miniature RCBOs take up less space in the consumer unit and so provide more wiring space for the installer, making the installation process easier and quicker. **==> picture [46 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> ACTUAL SIZE<br>**----- End of picture text -----**<br> Wylex RCBOs go one step further, they have switched neutral built in as standard, live and neutral conductors do not have to be disconnected for insulation resistance testing. This saves time and money, particularly for responsible landlords who regularly test installations during occupancy voids. *** BS 7671 IET Wiring Regulations** ## Consumer Unit MCBs & Miniature RCBOs NHXS MINIATURE RCBO (MCB sized 1 module with switched neutral) CURRENT RCD B CURVE C CURVE RATING RATING POLES MODULES NHXS1B06 NHXS1C06 6A 30mA 2 1 NHXS1B10 NHXS1C10 10A 30mA 2 1 NHXS1B16 NHXS1C16 16A 30mA 2 1 NHXS1B20 NHXS1C20 20A 30mA 2 1 NHXS1B25 - 25A 30mA 2 1 NHXS1B32 NHXS1C32 32A 30mA 2 1 NHXS1B40 NHXS1C40 40A 30mA 2 1 NHXL MINIATURE CIRCUIT BREAKERS (6kA) CURRENT B CURVE C CURVE RATING POLES MODULES - NHXLC03 3A 1 1 NHXLB06 NHXLC06 6A 1 1 NHXLB10 NHXLC10 10A 1 1 NHXLB16 NHXLC16 16A 1 1 NHXLB20 NHXLC20 20A 1 1 NHXLB25 - 25A 1 1 NHXLB32 NHXLC32 32A 1 1 NHXLB40 NHXLC40 40A 1 1 NHXLB50 NHXLC50 50A 1 1 • Type A - Pure AC and pulsating DC sensitivity WRCBL MINIATURE RCBO (MCB sized 2 module with switched neutral) CURRENT RCD B CURVE C CURVE RATING RATING POLES MODULES WRCBL45B2 WRCBL45C2 45A 30mA 2 2 WRCBL50B2 WRCBL50C2 50A 30mA 2 2 • Type A - Pure AC and pulsating DC sensitivity NHX Miniature RCBOs and NHXL MCBs are for use in Wylex Consumer Units as shown below **==> picture [367 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> NMX seamless all metal enclosures NM all metal enclosures<br>**----- End of picture text -----**<br> Not suitable for use with balcony type busbar units |MODEL RCBO MCB<br>~~SE~~|MODEL RCBO MCB<br>~~SE~~| |---|---| |Product brand name NHXS NHXL|Product brand name NHXS NHXL| |Product designation RCD operated circuit breaker Miniature circuit breaker|Product designation RCD operated circuit breaker Miniature circuit breaker| |GENERAL TECHNICAL DATA <br>~~SE~~|| |Number ofpoles 2 1|oles 2 1| |Number ofpoles / Note 1P+N 1P|oles / Note 1P+N 1P| |Number ofpoles / withprotection 1 1|rotection 1 1| |Trippingcharacteristics class B or C B or C|characteristics class B or C B or C| |RCD type A -|e A -| |Mechanical service life(switchingcycles)/ typical 10|ical 10,000 -| |Overvoltage category III 3<br>PRODUCT FUNCTION <br>Product function / neutral conductor switching Yes N/A<br>VOLTAGE <br>Surge current resistance / at (8/20) µs 1kA N/A<br>SUPPLY VOLTAGE<br>• at AC / rated value 240V 250V<br>~~eee~~<br>eee ee<br>~~ee~~<br>ee ee<br>~~ee~~<br>ee ee|| |• for testingequipment / minimum 195V -|ment / minimum 195V -| |Supply voltage frequency / rated value 50Hz 50Hz<br>PROTECTION CLASS <br>Protection class IP IP20 IP20<br>~~ee~~<br>ee ee|| |Energy limiting class 3 3<br>SWITCHING CAPACITY CURRENT <br>• acc. to EN 60898 / rated value 6kA 6kA<br>DISSIPATION<br>Power loss (W)<br>~~ee~~<br>ee<br>~~eee~~<br>ee ee<br>ee|| |• for rated value of the current / at AC / in hot operating state / per pole 1.5W 2.6W|| |• maximum 2.6W 2.6W|• maximum 2.6W 2.6W| |ELECTRICITY|| |Trippingresidual current / rated value 30mA N/A|residual current / rated value 30mA N/A| |Rated current in / IEC,DIN/VDE / at 40 cel 9.4A 15.08A|DIN/VDE / at 40 cel 9.4A 15.08A| |Current / at AC / rated value 6A - 40A 3A - 50A|Current / at AC / rated value 6A - 40A 3A - 50A| |CONNECTIONS<br>~~a~~|| |Connectable conductor cross-section / stranded|| |• minimum 0.75mm|• minimum 0.75mm20.75mm2| |• maximum 16mm|• maximum 16mm225mm2| |Connectable conductor cross-section|| |• solid - minimum 0.75mm|• solid - minimum 0.75mm20.75mm2| |• solid - maximum 16mm|• solid - maximum 16mm225mm2| |• finely stranded / with core end processing - minimum 0.75mm20.75mm2<br>TIGHTENING TORQUE / WITH SCREW-TYPE TERMINALS<br>Line terminal<br>~~ee~~<br>eee ~~ee~~|| |• minimum 2.5Nm|• minimum 2.5Nm 2.3Nm| |• maximum 3.0Nm|• maximum 3.0Nm 3.0Nm| |Load terminal|| |• minimum 1.2Nm|• minimum 1.2Nm 2.3Nm| |• maximum 2.0Nm|• maximum 2.0Nm 3.0Nm| |MECHANICAL DESIGN<br>~~SE~~|| |Height x Width x Depth 90mm x 18mm x 77mm 90mm x 18mm x 77mm|th 90mm x 18mm x 77mm 90mm x 18mm x 77mm| |Mounting position An|osition AnyAny| |Installation depth 70mm 70mm|th 70mm 70mm| |Number of width units 1 1|Number of width units 1 1| |Net weight 130g - 168g 116g - 156g|Net weight 130g - 168g 116g - 156g| |ENVIRONMENTAL CONDITIONS<br>~~Se~~|| |Degree ofpollution 2 2|ollution 2 2| |Influence of the surroundingtemperature Maximum 95% humidit|erature Maximum 95% humidityMaximum 95% humidity| |Ambient Temperature|| |• minimum -25ºC -25ºC|• minimum -25ºC -25ºC| |• maximum 55ºC 45ºC|• maximum 55ºC 45ºC| |• during storage / minimum -40ºC -40ºC|• during storage / minimum -40ºC -40ºC| |• duringstorage / maximum 75ºC 75ºC|e / maximum 75ºC 75ºC| ## ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE. eMail: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 01543 455020 Facsimile: 01543 455021 eMail: wylex.sales@electrium.co.uk TECHNICAL Telephone: 01543 438320 Facsimile: 01543 438321 eMail: wylex.technical@electrium.co.uk EXPORT SALES Telephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail: export@electrium.co.uk DUBAI OFFICE Telephone: +971 4 3660687 Facsimile: +971 4 3660676 eMail: btlv.sales.ae@siemens.com Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Wylex. Publication No. WY2382 10/17 Printed in England. @ElectriumNews or download the APP
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →