Image not available
Illustrative purposes only
NDR-75-48
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 76.8 W, 48 VDC, 1.6 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:76.8W; Output Voltage - Output 1:48V; Output Current - Output 1:1.6A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: NDR-75 Series
- No. of Outputs: 1 Output
- Output Power Max: 76.8W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 1.6A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 28.77 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- NDR 75 series** 75W Single Output Industrial DIN RAIL **==> picture [13 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** ℃℃ ■ **** ~~T~~ **** ~~é~~ **** _File Name:NDR-75-SPEC 2016-08-29_ **- NDR 75 series** 75W Single Output Industrial DIN RAIL ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|**SPECIFICATION**|||| |---|---|---|---|---|---| |Protection type : Shut down o/p voltage, re-power on to recover<br>℃<br><br><br><br><br><br><br><br>**OUTPUT**<br>**INPUT**<br>**PROTECTION**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.6**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load<br>60ms/230VAC 12ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]<br>47 ~ 63Hz<br>85.5%<br>1.45A/115VAC 0.9A/230VAC<br>29 ~ 33V<br>88%<br>20A/115VAC 35A/230VAC<br><1mA / 240VAC<br>14 ~ 17V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Ul508, TUV EN60950-1 approved;(meet EN60204-1)<br>-20 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>486.2K hrs min. MIL-HDBK-217F (25℃)<br>32*125.2*102mm (W*H*D)<br>0.51Kg; 28pcs/15.3Kg/1.22CUFT<br>**NDR-75-24**<br>24V<br>3.2A<br>0 ~ 3.2A<br>76.8W<br>120mVp-p<br>24 ~ 28V<br>±1.0%<br>±0.5%<br>±1.0%<br>**NDR-75-12**<br>12V<br>6.3A<br>0 ~ 6.3A<br>75.6W<br>80mVp-p<br>12 ~ 14V<br>±2.0%<br>±0.5%<br>±1.0%<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>56 ~ 65V<br>89%<br>**NDR-75-48**<br>48V<br>1.6A<br>0 ~ 1.6A<br>76.8W<br>150mVp-p<br>48 ~ 55V<br>±1.0%<br>±0.5%<br>±1.0%<br>Compliance to EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A|||||| ||Protection type : Shut down o/p voltage, re-power on to recover<br>℃<br><br><br>**OUTPUT**<br>**INPUT**<br>**PROTECTION**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.6**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load<br>60ms/230VAC 12ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]<br>47 ~ 63Hz<br>85.5%<br>1.45A/115VAC 0.9A/230VAC<br>29 ~ 33V<br>88%<br>20A/115VAC 35A/230VAC<br><1mA / 240VAC<br>14 ~ 17V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Ul508, TUV EN60950-1 approved;(meet EN60204-1)<br>-20 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>486.2K hrs min. MIL-HDBK-217F (25℃)<br>32*125.2*102mm (W*H*D)<br>0.51Kg; 28pcs/15.3Kg/1.22CUFT<br>**NDR-75-24**<br>24V<br>3.2A<br>0 ~ 3.2A<br>76.8W<br>120mVp-p<br>24 ~ 28V<br>±1.0%<br>±0.5%<br>±1.0%<br>**NDR-75-12**<br>12V<br>6.3A<br>0 ~ 6.3A<br>75.6W<br>80mVp-p<br>12 ~ 14V<br>±2.0%<br>±0.5%<br>±1.0%<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>56 ~ 65V<br>89%<br>**NDR-75-48**<br>48V<br>1.6A<br>0 ~ 1.6A<br>76.8W<br>150mVp-p<br>48 ~ 55V<br>±1.0%<br>±0.5%<br>±1.0%<br>Compliance to EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A||**NDR-75-12**|**NDR-75-24**|**NDR-75-48**| |||**DC VOLTAGE**|12V|24V|48V| |||**RATED CURRENT**|6.3A|3.2A|1.6A| |||**CURRENT RANGE**|0 ~ 6.3A|0 ~ 3.2A|0 ~ 1.6A| |||**RATED POWER**|75.6W|76.8W|76.8W| |||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|120mVp-p|150mVp-p| |||**VOLTAGE ADJ. RANGE**|12 ~ 14V|24 ~ 28V|48 ~ 55V| |||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%|±1.0%| |||**LINE REGULATION**|±0.5%|±0.5%|±0.5%| |||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%| |||**SETUP, RISE TIME**|1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load||| |||**HOLD UP TIME (Typ.)**|60ms/230VAC 12ms/115VAC at full load||| |||**VOLTAGE RANGENote.6**|90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]||| |||**FREQUENCY RANGE**|47 ~ 63Hz||| |||**EFFICIENCY (Typ.)**|85.5%|88%|89%| |||**AC CURRENT (Typ.)**|1.45A/115VAC 0.9A/230VAC||| |||**INRUSH CURRENT (Typ.)**|20A/115VAC 35A/230VAC||| |||**LEAKAGE CURRENT**|<1mA / 240VAC||| |||**OVERLOAD**|105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed||| |||**OVER VOLTAGE**|29 ~ 33V<br>14 ~ 17V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>56 ~ 65V||| |||**OVER TEMPERATURE**|Protection type : Shut down o/p voltage, re-power on to recover||| |||**WORKING TEMP.**|-20 ~ +70℃(Refer to "Derating Curve")||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)||| |||**VIBRATION**|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||| |||**SAFETY STANDARDS**|Ul508, TUV EN60950-1 approved;(meet EN60204-1)||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH||| |||**EMC EMISSION**|Compliance to EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3||| |||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A||| |||**MTBF**|486.2K hrs min. MIL-HDBK-217F (25℃)||| |||**DIMENSION**|32*125.2*102mm (W*H*D)||| |||**PACKING**|0.51Kg; 28pcs/15.3Kg/1.22CUFT||| |||℃<br><br>|||| |||<br><br><br><br>|||| _File Name:NDR-75-SPEC 2016-08-29_ **- NDR 75 series** 75W Single Output Industrial DIN RAIL ## **Block Diagram** **==> picture [470 x 330] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 85KHz<br>EMI FILTER POWER RECTIFIERS +V<br>I/P & SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P.<br>O.L.P.<br>DETECTION<br>FG<br>PWM CIRCUIT<br>O.T.P. CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100 230VAC Others 100<br>90<br>80<br>80<br>115VAC<br>60 12V(115VAC only) 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-20 -10 0 10 20 30 40 45 50 60 70 (VERTICAL) 90 100 125 135 145 155 165 175 180 200 230 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:NDR-75-SPEC 2016-08-29_ **- NDR 75 series** 75W Single Output Industrial DIN RAIL **==> picture [465 x 445] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Case No.221B Unit:mm<br>Top View<br>102 32<br>1 2 3 4<br>TB2<br>(12V,24V only)<br>DC OK<br>+V ADJ.<br>(48V only)<br>TB1<br>1 2 3<br>Side View Front View Side View<br>Terminal Pin No. Assignment (TB1)<br>Pin No. Assignment<br>1 FG<br>2 AC/N or DC -<br>3 AC/L or DC +<br>Terminal Pin No. Assignment (TB2)<br>Pin No. Assignment<br>1,2 DC OUTPUT -V<br>3,4 DC OUTPUT+V<br>Bottom View<br>39<br>125.2<br>**----- End of picture text -----**<br> **==> picture [115 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Installation Instruction<br>**----- End of picture text -----**<br> **==> picture [478 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the USER MANUAL on<br>http://www.meanwell.com/search/NDR-75/NDR_manual.pdf<br>ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>Back View<br>35<br>**----- End of picture text -----**<br> _File Name:NDR-75-SPEC 2016-08-29_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →