Image not available
Illustrative purposes only
NDR-240-24
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 240 W, 24 VDC, 10 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:240W; Output Voltage - Output 1:24V; Output Current - Output 1:10A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage
- SVHC: No SVHC (25-Jun-2025)
- Product Range: NDR-240 Series
- No. of Outputs: 1 Output
- Output Power Max: 240W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 10A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 63.83 € |
| Current stock | 50+ |
| Lead time | 30 days |
240W Single Output Industrial DIN RAIL ## **- NDR 240 series** **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> ## ■ THOMAS SAMUEL THOMAS SAMUEL BauarSicherheitbeegelodwacmat geprufto ges g **www.ID 2000000000tuv.com (for 48V onlyK60950-1** cc[&] **)**[ @©-] @[C] Z ~~[S]~~ N **TPTC004**[Hil] 3)[®] **IS13252 BS EN/EN62368-1** ~~[G_I]~~[CBcexk] **IEC62368-1** as ■ Applications * Industrial control system * Semi-conductor fabrication equipment Over voltage * Factory automation * Electro-mechanical or 15 ■ GTIN CODE https://www.meanwell.com/serviceGTIN.aspx ## ■ ℃ ℃ **==> picture [13 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:NDR-240-SPEC 2024-02-23_ **- NDR 240 series** ## 240W Single Output Industrial DIN RAIL ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load<br>28ms/230VAC 22ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>2.5A/115VAC 1.3A/230VAC<br>29 ~ 33V<br>88.5%<br>56 ~ 65V<br>90%<br>20A/115VAC 35A/230VAC<br><1mA / 240VAC<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL508, TUV BS EN/EN62368-1,<br>, BSMI CNS14336-1,<br>,KC K60950-1(<br>)approved;<br>IS13252(Part1)/IEC60950-1<br>for 48V only<br>EAC TP TC 004<br>Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438,<br>KSC 9832(for 48V only)<br>Compliance to<br>EN61000-4-2,3,4,5,6,8,11,<br>EN55035,<br>EN61000-6-2 (<br>EN50082-2),<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>(for 48V only)<br>EN61204-3, heavy industry level,EAC TP TC 020,KSC 9835<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>63*125.2*113.5mm (W*H*D)<br>1Kg; 12pcs/13Kg/1.22CUFT<br>**NDR-240-24**<br>**NDR-240-48**<br>24V<br>48V<br>10A<br>5A<br>0 ~ 10A<br>0 ~ 5A<br>240W<br>240W<br>150mVp-p<br>150mVp-p<br>24 ~ 28V<br>48 ~ 55V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>μ<br>μ<br>F<br>F<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>℃<br>℃<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>:<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>**POWER FACTOR (Typ.)**<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>(meet BS EN/EN60204-1)<br>1645.2K hrs min.<br>Telcordia SR-332 (Bellcore) ; 230.2K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>a<br>a<br>~~ee~~<br>a<br>a<br>~~ee~~<br>a~~ee~~<br>a<br>a<br>a<br>~~ee~~<br>RR<br>Re<br>~~ee~~<br>a<br>a<br>~~a Ce~~<br>~~Ce~~<br>~~a~~<br>~~|~~<br>**e**s<br>~~e~~<br>a<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~a~~<br>Re<br>a<br>a<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltage. Please check the derating curve for more details.<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than<br>2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load<br>28ms/230VAC 22ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>2.5A/115VAC 1.3A/230VAC<br>29 ~ 33V<br>88.5%<br>56 ~ 65V<br>90%<br>20A/115VAC 35A/230VAC<br><1mA / 240VAC<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL508, TUV BS EN/EN62368-1,<br>, BSMI CNS14336-1,<br>,KC K60950-1(<br>)approved;<br>IS13252(Part1)/IEC60950-1<br>for 48V only<br>EAC TP TC 004<br>Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438,<br>KSC 9832(for 48V only)<br>Compliance to<br>EN61000-4-2,3,4,5,6,8,11,<br>EN55035,<br>EN61000-6-2 (<br>EN50082-2),<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>(for 48V only)<br>EN61204-3, heavy industry level,EAC TP TC 020,KSC 9835<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>63*125.2*113.5mm (W*H*D)<br>1Kg; 12pcs/13Kg/1.22CUFT<br>**NDR-240-24**<br>**NDR-240-48**<br>24V<br>48V<br>10A<br>5A<br>0 ~ 10A<br>0 ~ 5A<br>240W<br>240W<br>150mVp-p<br>150mVp-p<br>24 ~ 28V<br>48 ~ 55V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>μ<br>μ<br>F<br>F<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>℃<br>℃<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>:<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>**POWER FACTOR (Typ.)**<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>(meet BS EN/EN60204-1)<br>1645.2K hrs min.<br>Telcordia SR-332 (Bellcore) ; 230.2K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>a<br>a<br>~~ee~~<br>a<br>a<br>~~ee~~<br>a~~ee~~<br>a<br>a<br>a<br>~~ee~~<br>RR<br>Re<br>~~ee~~<br>a<br>a<br>~~a Ce~~<br>~~Ce~~<br>~~a~~<br>~~|~~<br>**e**s<br>~~e~~<br>a<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~a~~<br>Re<br>a<br>a<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltage. Please check the derating curve for more details.<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than<br>2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**NDR-240-24**|**NDR-240-48**| |---|---|---|---| ||**DC VOLTAGE**<br>a|24V|48V| ||**RATED CURRENT**<br>a<br>a|10A|5A| ||**CURRENT RANGE**<br>a<br>~~ee~~<br>a|0 ~ 10A<br>~~ee~~|0 ~ 5A<br>~~ee~~| ||**RATED POWER**<br>~~ee~~<br>a|240W<br>~~ee~~|240W<br>~~ee~~| ||**RIPPLE & NOISE (max.) Note.2**<br>a<br>a|150mVp-p|150mVp-p| ||**VOLTAGE ADJ. RANGE**<br>a<br>~~ee~~<br>a|24 ~ 28V<br>~~ee~~<br>|48 ~ 55V<br>~~ee~~<br>| ||**VOLTAGE TOLERANCE Note.3**<br>~~ee~~<br>a|±1.0%<br>~~ee~~<br>|±1.0%<br>~~ee~~<br>| ||**LINE REGULATION**<br>a~~ee~~|±0.5%<br>~~ee~~|±0.5%<br>~~ee~~| ||**LOAD REGULATION**<br>~~ee~~<br>a|±1.0%<br>~~ee~~|±1.0%<br>~~ee~~| ||**SETUP, RISE TIME**<br>a<br>a|1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load|| ||**HOLD UP TIME (Typ.)**<br>a<br>a|28ms/230VAC 22ms/115VAC at full load|| ||**VOLTAGE RANGE**<br>**Note.4**<br>a<br>~~ee~~<br>RR|90 ~ 264VAC 127 ~ 370VDC<br>~~ee~~|| ||**FREQUENCY RANGE**<br>~~ee~~<br>RR<br>Re|47 ~ 63Hz<br>~~ee~~|| ||**POWER FACTOR (Typ.)**<br>RR<br>Re<br>~~ee~~|PF>0.98/115VAC, PF>0.95/230VAC at full load<br>~~ee~~|| ||**EFFICIENCY (Typ.)**<br>Re<br>~~ee~~|88.5%<br>~~ee~~|90%<br>~~ee~~| ||**AC CURRENT (Typ.)**<br>a|2.5A/115VAC 1.3A/230VAC|| ||**INRUSH CURRENT (Typ.)**<br>a<br>~~a~~|20A/115VAC 35A/230VAC<br>~~Ce~~|| ||**LEAKAGE CURRENT**<br>a<br>~~a~~|<1mA / 240VAC<br>~~Ce~~|| ||**OVERLOAD**<br>~~a ~~|105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br> ~~Ce~~<br>~~Ce~~|| ||**OVER VOLTAGE**<br>**e**s|29 ~ 33V<br>56 ~ 65V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~Ce~~<br>~~a~~<br>~~|~~|| ||**OVER TEMPERATURE**<br>**e**s|Shut down o/p voltage, recovers automatically after temperature goes down|| ||**WORKING TEMP.**<br>**e**s|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>~~e~~|| ||**WORKING HUMIDITY**<br>a|20 ~ 95% RH non-condensing|| ||**STORAGE TEMP., HUMIDITY**<br>a<br>~~ee~~|-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>~~ee~~|| ||**TEMP. COEFFICIENT**<br>~~ee~~<br>~~ee~~|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>~~ee~~<br>~~ee~~|| ||**VIBRATION**<br>~~ee~~<br>~~a~~|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>~~ee~~<br>~~a~~|| ||**SAFETY STANDARDS**<br>~~a~~|UL508, TUV BS EN/EN62368-1,<br>, BSMI CNS14336-1,<br>,KC K60950-1(<br>)approved;<br>IS13252(Part1)/IEC60950-1<br>for 48V only<br>EAC TP TC 004<br>(meet BS EN/EN60204-1)<br>~~a~~|| ||**WITHSTAND VOLTAGE**<br>~~a~~<br>Re|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>~~a~~|| ||**ISOLATION RESISTANCE**<br>Re|I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|| ||**EMC EMISSION**<br>Re|Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438,<br>KSC 9832(for 48V only)|| ||**EMC IMMUNITY**<br>a|Compliance to<br>EN61000-4-2,3,4,5,6,8,11,<br>EN55035,<br>EN61000-6-2 (<br>EN50082-2),<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>(for 48V only)<br>EN61204-3, heavy industry level,EAC TP TC 020,KSC 9835|| ||**MTBF**<br>a<br>a|1645.2K hrs min.<br>Telcordia SR-332 (Bellcore) ; 230.2K hrs min. MIL-HDBK-217F (25<br>)<br>℃|| ||**DIMENSION**<br>a<br>a|63*125.2*113.5mm (W*H*D)|| ||**PACKING**<br>1Kg; 12pcs/13Kg/1.22CUFT<br>℃<br>μ<br>μ<br>F<br>F<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>℃<br>℃<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>:<br>a<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltage. Please check the derating curve for more details.<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than<br>2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to||| ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:NDR-240-SPEC 2024-02-23_ **- NDR 240 series** ## 240W Single Output Industrial DIN RAIL **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 70KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P.<br>O.L.P.<br>DETECTION<br>FG<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>O.T.P.<br>Derating Curve Output derating VS input voltage<br>100<br>100<br>90<br>80<br>80<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-20 0 10 20 30 40 50 60 70 (VERTICAL) 90 100 125 135 145 155 165 175 180 200 230 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:NDR-240-SPEC 2024-02-23_ **- NDR 240 series** 240W Single Output Industrial DIN RAIL **==> picture [496 x 660] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Case No.979C Unit:mm<br>Top View<br>113.5 63<br>1 2 3 4<br>TB2<br>+V ADJ. +<br>DC OK<br>TB1<br>1 2 3<br>Side View Front View Side View<br>Terminal Pin No. Assignment (TB1)<br>Pin No. Assignment<br>1 FG<br>2 AC/N or DC -<br>3 AC/L or DC +<br>Terminal Pin No. Assignment (TB2)<br>Pin No. Assignment<br>1,2 DC OUTPUT -V<br>3,4 DC OUTPUT+V<br>Bottom View<br>Installation Instruction<br>This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>Back View<br>Installation Manual<br>35<br>36<br>125.2<br>**----- End of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html _File Name:NDR-240-SPEC 2024-02-23_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →