Image not available
Illustrative purposes only
NDR-120-24
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 120 W, 24 VDC, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:120W; Output Voltage - Output 1:24V; Output Current - Output 1:5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (25-Jun-2025)
- Product Range: NDR-120 Series
- No. of Outputs: 1 Output
- Output Power Max: 120W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 36.57 € |
| Current stock | 200+ |
| Lead time | 30 days |
**- NDR 120 series** 120W Single Output Industrial DIN RAIL **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [212 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>B Was EAL E y www.ID 2000000000tuv.com - CBC € cA<br>TPTC004 BS EN/EN62368-1 IEC62368-1<br>■<br>**----- End of picture text -----**<br> > ■ GTIN CODE > MW Searet: ~~J__________~~ https://www.meanwell.com/serviceGTIN.aspx **==> picture [13 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> > ℃ and/70O ℃ _ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:NDR-120-SPEC 2024-02-24_ **- NDR 120 series** ## 120W Single Output Industrial DIN RAIL ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.6**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load<br>16ms/230VAC 10ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]<br>47 ~ 63Hz<br>85.5%<br>2.25A/115VAC 1.3A/230VAC<br>29 ~ 33V<br>88%<br>56 ~ 65V<br>89%<br>20A/115VAC 35A/230VAC<br><1mA / 240VAC<br>14 ~ 17V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>UL508, TUV BS EN/EN62368-1,<br>approved;(meet BS EN/EN60204-1)<br>EAC TP TC 004<br>Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020<br>Compliance to<br>EN61000-4-2,3,4,5,6,8,11,<br>EN55035,<br>EN61000-6-2 (<br>EN50082-2),<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>,<br>EN61204-3, heavy industry level EAC TP TC 020<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>40*125.2*113.5mm (W*H*D)<br>0.6Kg; 20pcs/13Kg/1.16CUFT<br>**NDR-120-24**<br>**NDR-120-48**<br>24V<br>48V<br>5A<br>2.5A<br>0 ~ 5A<br>0 ~ 2.5A<br>120W<br>120W<br>120mVp-p<br>150mVp-p<br>24 ~ 28V<br>48 ~ 55V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>**NDR-120-12**<br>12V<br>10A<br>0 ~ 10A<br>120W<br>100mVp-p<br>12 ~ 14V<br>±2.0%<br>±0.5%<br>±1.0%<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>μ<br>μ<br>F<br>F<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>2636.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 453.3K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~GC~~<br>Re~~eG~~<br>~~eG~~<br>~~eG~~<br>a ~~OC~~<br>~~eC~~<br>~~eG~~<br>ee~~GG~~<br>~~PG~~<br>a<br>re<br>Re<br>a<br>eeGe<br>a<br>a~~eG~~<br>~~Ce~~<br>~~Pe~~<br>~~se~~<br>~~Cn~~<br>ee<br>rs<br>aaee<br>Ce~~eG~~<br>~~Pe~~<br>ee<br>a<br>Cea<br>I<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 —_ofambienttemperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0.1<br>&47<br>parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered acomponent which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>5. Installation clearances<br>:40mm on top, 20mm on the bottom, 5mm on the leftand right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. Derating may be needed under low input voltage. Please check the derating curve for more details.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than<br>2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.6**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load<br>16ms/230VAC 10ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]<br>47 ~ 63Hz<br>85.5%<br>2.25A/115VAC 1.3A/230VAC<br>29 ~ 33V<br>88%<br>56 ~ 65V<br>89%<br>20A/115VAC 35A/230VAC<br><1mA / 240VAC<br>14 ~ 17V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>UL508, TUV BS EN/EN62368-1,<br>approved;(meet BS EN/EN60204-1)<br>EAC TP TC 004<br>Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020<br>Compliance to<br>EN61000-4-2,3,4,5,6,8,11,<br>EN55035,<br>EN61000-6-2 (<br>EN50082-2),<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>,<br>EN61204-3, heavy industry level EAC TP TC 020<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>40*125.2*113.5mm (W*H*D)<br>0.6Kg; 20pcs/13Kg/1.16CUFT<br>**NDR-120-24**<br>**NDR-120-48**<br>24V<br>48V<br>5A<br>2.5A<br>0 ~ 5A<br>0 ~ 2.5A<br>120W<br>120W<br>120mVp-p<br>150mVp-p<br>24 ~ 28V<br>48 ~ 55V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>**NDR-120-12**<br>12V<br>10A<br>0 ~ 10A<br>120W<br>100mVp-p<br>12 ~ 14V<br>±2.0%<br>±0.5%<br>±1.0%<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>μ<br>μ<br>F<br>F<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>2636.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 453.3K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~GC~~<br>Re~~eG~~<br>~~eG~~<br>~~eG~~<br>a ~~OC~~<br>~~eC~~<br>~~eG~~<br>ee~~GG~~<br>~~PG~~<br>a<br>re<br>Re<br>a<br>eeGe<br>a<br>a~~eG~~<br>~~Ce~~<br>~~Pe~~<br>~~se~~<br>~~Cn~~<br>ee<br>rs<br>aaee<br>Ce~~eG~~<br>~~Pe~~<br>ee<br>a<br>Cea<br>I<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 —_ofambienttemperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0.1<br>&47<br>parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered acomponent which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>5. Installation clearances<br>:40mm on top, 20mm on the bottom, 5mm on the leftand right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. Derating may be needed under low input voltage. Please check the derating curve for more details.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than<br>2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**NDR-120-12**|**NDR-120-24**|**NDR-120-48**| |---|---|---|---|---| ||**DC VOLTAGE**<br>~~GC~~<br>Re|12V<br>~~GC~~<br>~~eG~~|24V<br>~~GC~~<br>~~eG~~|48V<br>~~GC~~<br>~~eG~~| ||**RATED CURRENT**<br>~~GC~~<br>Re|10A<br>~~GC~~<br>~~eG~~|5A<br>~~GC~~<br>~~eG~~|2.5A<br>~~GC~~<br>~~eG~~| ||**CURRENT RANGE**<br>Re<br>~~eG~~|0 ~ 10A<br>~~eG~~<br>~~eG~~|0 ~ 5A<br>~~eG~~<br>~~eG~~|0 ~ 2.5A<br>~~eG~~<br>~~eG~~| ||**RATED POWER**<br>~~eG~~<br>~~eG~~|120W<br>~~eG~~<br>~~eG~~|120W<br>~~eG~~<br>~~eG~~|120W<br>~~eG~~<br>~~eG~~| ||**RIPPLE & NOISE (max.) Note.2**<br>~~eG~~<br>a|100mVp-p<br>~~eG~~<br>~~OC~~|120mVp-p<br>~~eG~~<br>~~OC~~|150mVp-p<br>~~eG~~<br>~~OC~~| ||**VOLTAGE ADJ. RANGE**<br>a <br>~~eC~~|12 ~ 14V<br> ~~OC~~<br>~~eC~~|24 ~ 28V<br>~~OC~~<br>~~eC~~|48 ~ 55V<br>~~OC~~<br>~~eC~~| ||**VOLTAGE TOLERANCE Note.3**<br>~~eC~~<br>~~eG~~<br>ee|±2.0%<br>~~eC~~<br>~~eG~~<br>~~GG~~|±1.0%<br>~~eC~~<br>~~eG~~<br>~~GG~~|±1.0%<br>~~eC~~<br>~~eG~~<br>~~GG~~| ||**LINE REGULATION**<br>~~eG~~<br>ee|±0.5%<br>~~eG~~<br>~~GG~~|±0.5%<br>~~eG~~<br>~~GG~~|±0.5%<br>~~eG~~<br>~~GG~~| ||**LOAD REGULATION**<br>ee<br>~~PG~~<br>a|±1.0%<br>~~GG~~<br>~~PG~~|±1.0%<br>~~GG~~<br>~~PG~~|±1.0%<br>~~GG~~<br>~~PG~~| ||**SETUP, RISE TIME**<br>~~PG~~<br>a<br>re|1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load<br>~~PG~~||| ||**HOLD UP TIME (Typ.)**<br>a<br>re<br>Re|16ms/230VAC 10ms/115VAC at full load||| ||**VOLTAGE RANGE**<br>**Note.6**<br>re<br>Re|90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]||| ||**FREQUENCY RANGE**<br>Re<br>a<br>ee|47 ~ 63Hz<br>Ge||| ||**EFFICIENCY (Typ.)**<br>a<br>ee<br>a|85.5%<br>Ge|88%|89%| ||**AC CURRENT (Typ.)**<br>ee<br>a<br>a|2.25A/115VAC 1.3A/230VAC<br>Ge<br>||| ||**INRUSH CURRENT (Typ.)**<br>a<br>a~~eG~~|20A/115VAC 35A/230VAC<br>~~eG~~||| ||**LEAKAGE CURRENT**<br>a~~eG~~|<1mA / 240VAC<br>~~eG~~||| ||**OVERLOAD**|105 ~ 130% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>~~Ce~~<br>~~Pe~~||| ||**OVER VOLTAGE**<br>ee|29 ~ 33V<br>56 ~ 65V<br>14 ~ 17V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~Pe~~<br>~~se~~<br>~~Cn~~||| ||**OVER TEMPERATURE**<br>ee<br>rs|Shut down o/p voltage, re-power on to recover<br>~~Cn~~||| ||**WORKING TEMP.**<br>ee<br>rs<br>a|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>~~Cn~~||| ||**WORKING HUMIDITY**<br>rs<br>aa|20 ~ 95% RH non-condensing||| ||**STORAGE TEMP., HUMIDITY**<br>aaee|-40 ~ +85<br>, 10 ~ 95% RH<br>℃||| ||**TEMP. COEFFICIENT**<br>aee<br>Ce|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>||| ||**VIBRATION**<br>ee<br>Ce|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>||| ||**SAFETY STANDARDS**<br>Ce~~eG~~<br>~~Pe~~|UL508, TUV BS EN/EN62368-1,<br>approved;(meet BS EN/EN60204-1)<br>EAC TP TC 004<br>~~eG~~<br>~~Pe~~||| ||**WITHSTAND VOLTAGE**<br>~~Pe~~<br>ee|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>~~Pe~~||| ||**ISOLATION RESISTANCE**<br>ee<br>a|I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||| ||**EMC EMISSION**<br>ee<br>a|Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020||| ||**EMC IMMUNITY**<br>a<br>Ce|Compliance to<br>EN61000-4-2,3,4,5,6,8,11,<br>EN55035,<br>EN61000-6-2 (<br>EN50082-2),<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>,<br>EN61204-3, heavy industry level EAC TP TC 020||| ||**MTBF**<br>Cea|2636.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 453.3K hrs min. MIL-HDBK-217F (25<br>)<br>℃||| ||**DIMENSION**<br>Cea|40*125.2*113.5mm (W*H*D)||| ||**PACKING**<br>a<br>I|0.6Kg; 20pcs/13Kg/1.16CUFT||| ||℃<br>μ<br>μ<br>F<br>F<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>I<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 —_ofambienttemperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0.1<br>&47<br>parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered acomponent which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>5. Installation clearances<br>:40mm on top, 20mm on the bottom, 5mm on the leftand right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. Derating may be needed under low input voltage. Please check the derating curve for more details.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than<br>2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|||| _File Name:NDR-120-SPEC 2024-02-24_ **- NDR 120 series** ## 120W Single Output Industrial DIN RAIL **==> picture [481 x 337] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 70KHz<br>EMI FILTER POWER RECTIFIERS +V<br>I/P & SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P.<br>O.L.P.<br>DETECTION<br>FG<br>PWM CIRCUIT<br>O.T.P. CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100 230VAC 12V,24V,48V 100<br>90<br>80<br>115VAC 80<br>60 12V 70<br>50 (115VAC only)<br>60<br>40<br>50<br>20<br>40<br>-20 -10 0 10 20 30 40 45 50 60 70 (VERTICAL) 90 100 125 135 145 155 165 175 180 200 230 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:NDR-120-SPEC 2024-02-24_ **- NDR 120 series** 120W Single Output Industrial DIN RAIL **==> picture [491 x 634] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Case No.992D Unit:mm<br>Top View<br>113.5<br>40<br>1 2 3 4<br>TB2<br>+V ADJ. +<br>DC OK<br>TB1<br>1 2 3<br>Side View Front View Side View<br>Terminal Pin No. Assignment (TB1)<br>Pin No. Assignment<br>1 FG<br>2 AC/N or DC -<br>3 AC/L or DC +<br>Terminal Pin No. Assignment (TB2)<br>Pin No. Assignment<br>1,2 DC OUTPUT -V<br>3,4 DC OUTPUT+V<br>Bottom View<br>Installation Instruction<br>This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>Back View<br>35<br>35<br>125.2<br>**----- End of picture text -----**<br> **==> picture [97 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Installation Manual<br>**----- End of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html _File Name:NDR-120-SPEC 2024-02-24_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →