NC1V-1111-30AA
CIRCUIT BREAKER, HYD-MAG, 1P, 250V, 30A
- Manufacturer: IDEC
- Product type: Magnetic Hydraulic Circuit Breakers
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 24.28 € |
| Current stock | 10+ |
| Lead time | 30 days |
## NC1V Circuit Protectors ## IDEC's original Spring-up Terminals and Cover Provide IP20 Finger-safe Protection. **==> picture [381 x 219] intentionally omitted <==** **----- Start of picture text -----**<br> 17.5 mm 35.0 mm 52.5 mm<br>| |<br>(1-pole) (2-pole) Auxiliary/alarm contact terminals (3-pole)<br>are equipped with terminal covers.<br>78.8 mm<br>**----- End of picture text -----**<br> ## **Finger-safe, spring-up terminals reduce wiring time.** Ring terminal tabs can be installed easily, and screws are held secure. ## **Retractable Actuator** The actuator retracts when the circuit protector turns on. Inadvertent operation, due to touching the actuator, is prevented. Status of the circuit protector can easily be confirmed by viewing the position of the actuator. **==> picture [33 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Retractable<br>Actuator<br>**----- End of picture text -----**<br> **==> picture [113 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> ON OFF<br>**----- End of picture text -----**<br> ## **Slim Housing Saves Space** ## **Main Circuit Terminals are Fingersafe (IP20)** Spring-up, fingersafe structure requires no terminal cover. |1-pole|17.5mm Wide| |---|---| |2-pole|35.0mm Wide| |3-pole|52.5mm Wide| ## **Auxiliary/Alarm Contact Terminals are Equipped with a Terminal Cover** Voltage coil terminals on the relay trip version are also equipped with a terminal cover as standard. 2 ## Auxiliary/Alarm Contact, and Relay Trip Voltage Coil Terminals are Equipped with a Terminal Cover. **35mm-wide DIN Rail Mounting or Direct Panel Mounting** ## **Distinguishing Characteristics** Wide variety of rated currents and tripping curves. One and 2-pole models are AC/DC compatible and allow for a reduction in inventory. ## **Rated Short-circuit Capacity 2500A** ## **Available with Inertia Delay** Allows for use with large inrush currents such as motors and lamps. **Conforms to various international standards** **==> picture [206 x 228] intentionally omitted <==** **----- Start of picture text -----**<br> After tripping, the retractable actuator is<br>WEOCEOSO&<br>in the middle position.<br>Circuit protector must be turned off before it can be reset.<br>Se 2 #<br>a =a<br>ON OFF Tripped<br>**----- End of picture text -----**<br> ## **Safe Trip-free Mechanism** The circuit remains open even when the operator is turned on after tripping (unit must be manually reset after removing the cause of the tripping). ## **Available with Auxiliary or Alarm Contacts** **==> picture [112 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Auxiliary or Alarm Contact<br>(Shown without terminal cover.)<br>**----- End of picture text -----**<br> 3 ## NC1V Circuit Protectors ## **IDEC’s original spring-up, fingersafe terminals enhance reliability and safety.** - Integrated electric shock protection structure (IP20). - Auxiliary/alarm contact terminals and voltage coil terminals on the relay trip types are equipped with terminal covers. - Spring-up, fingersafe terminals reduce wiring time. - Ring terminals can be installed. Captive terminal screws. - Available with inertia delay - Available with auxiliary or alarm contacts - Rated short-circuit capacity: 2500A - Slim, space-saving housing - 1-pole: 17.5mm wide - 2-pole: 35.0mm wide - 3-pole: 52.5mm wide - Retractable actuator - The trip-free mechanism maintains the circuit open even when the operator is turned on after tripping. **==> picture [215 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> Applicable Standards Certification Mark Certification Organization(File No.)<br>UL1077 E68029<br>CSA C22.2 No. 235 LR83454<br>B07 09 13332 063<br>EN60934<br>European Commission's<br>c Low Voltage Directive e<br>GB17701-1999 No. 2008010307265840<br>et <) e<br>Electrical Applicance and Series Trip<br>Material Safety Law JET<br>Technical Standard Relay Trip<br>a oe.<br>Note: TÜV, CE, and CCC marks are applicable for series trip type only.<br>**----- End of picture text -----**<br> ## **Specifications** **==> picture [434 x 308] intentionally omitted <==** **----- Start of picture text -----**<br> a Operator Style Retractable actuator D<br>n Internal Circuit Series trip (current trip), Relay trip (voltage trip) D<br>n Protection Method Hydraulic magnetic tripping system, Ma D gnetic tripping system (voltage trip)<br>DQ No. of Poles 1-pole 2-pole 3-pole<br>nD Rated Voltage (AC/DC) (Note 1) 250V AC 50/60Hz, 65V DC 250V AC 50/60Hz, 125V DC 250V AC, 50/60Hz<br>Rated Short-circuit 250V AC, 2500A 250V AC, 2500A<br>Capacity 65V DC, 2500A 125V DC, 2500A 250V AC, 2500A<br>Series Trip(Current Trip) es Rated Current 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A<br>Operation Characteristics Time delay curve curve M (slow), curve A (medium), S (instantaneous)<br>— ——eS (Note 2) Curves M and A are avilable with inertia delay.<br>Relay Trip Rated Current 30A<br>(Voltage Trip) 24 to 48V DC (at 25°C)<br>(Note 3) Trip Voltage Voltage application duration 10 sec maximum, tripping time 0.1 sec maximum (at rated voltage)<br>ee en<br>Auxiliary Contact/ Contact Rating 125V AC 3A (resistive load), 30V DC 2A (resistive load)<br>a Alarm Contact eee Minimum Applicable Load oomo 24V DC 1mA (resistive load, reference value) moons,<br>Insulation Resistance 100 MΩ minimum (500V DC megger)<br>2000V AC, 1 minute (between terminals when main contacts are open, between live parts of different<br>Dielectric Strength poles, between live and dead parts)<br>600V AC (between terminals when auxiliary circuits are open)<br>Vibration Resistance Damage limits: 147 m/s [2] (10 to 55 Hz) (1-pole, 2-pole), 78 m/s [2] (3-pole)<br>a (with rated current applied) Operating extremes: 98 m/s [2] (1-pole, 2-pole), 78 m/s [2] (3-pole)<br>Shock Resistance<br>Damage limits: 490 m/s [2] (1-pole, 2-pole), 297 m/s [2] (3-pole)<br>(S time delay curve: 80% rated current,<br>Operating extremes: 196 m/s [2] (S, A, M types)<br>A, M time delay curve: 100% rated current)<br>a Electrical Life 10,000 cyles minimum (at rated curent), 10 operations per minute<br>a Reference Temperature 40°C<br>−10 to +60°C (no freezing)<br>Operating Tempperature Rated current is based on an ambient temperature of 40°C. When the operating temperature exceeds<br>40°C, derate the rated current by using the factors shown below.<br>RR Operating Humidity 45 to 85% RH (no condensation)<br>Main Circuit Terminal Spring-up, fingersafe terminal: M4 screw (up to 20A), M5 screw (25A and 30A)<br>Terminal Style Auxiliary/Alarm Contacts, M3.5 screw<br>a Voltage Coil Terminal ees<br>a Weight (approx.) 1-pole: 90g, 2-pole: 170g, 3-pole: 260g<br>Note 1: 3-pole type is for AC voltage only.<br>Note 2: For S (instantaneous) tripping curve, humming sound may be caused when used in an AC sinusoidal-wave current circuit around 80% of Operating Temp. Derating Factor<br>the rated current, however, the performance of the circuit protector will not be affected. 50°C 0.9<br>To avoid unnecessary tripping, do not use in circuits where inrush currents may be present. 55°C 0.8<br>Note 3: Relay trip (voltage trip) type is not equipped with an overcurrent trip function. 60°C 0.7<br>**----- End of picture text -----**<br> - Do not use the NC1V circuit protectors in environments where they are exposed to extreme temperature, humidity, dust, corrosive gases, vibration, shock, or in a circuit where inrush current may be present, otherwise unnecessary operations and damage may occur. 4 NC1V Circuit Protectors ## **Type No. Development** NC1V - 2 1 00 F - 30A A DC24V 1 **Type** 8 **Voltage Trip Coil Voltage** NC1V: Flap actuator type DC24V: 24-48V DC DIN rail and panel mounting ∗ Specified for relay trip only. 2 **No. of Poles** 7 **Time Delay Curve** 1: 1-pole M: Slow 2: 2-pole A: Medium 3: 3-pole S: Instantaneous 3 **Internal Circuit** ∗ For both AC/DC. 1: Series trip (current trip) ∗ Specified for series trip only. 5: Relay trip (voltage trip) 6 **Rated Current** 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 4 **Auxiliary/Alarm Contacts** 5A, 7A, 10A 15A, 20A, 25A, 30A 00: None ∗ Specified for series trip only. 11: With one auxiliary contact 12: With two auxiliary contacts 5 **Inertia Delay** 13: With three auxiliary contacts Blank: Without 21: With one alarm contact F: With 31: With one auxiliary contact and one alarm contact ∗ Inertia delay is for AC voltage only. 32: With two auxiliary contacts and one alarm contact ∗ Available with medium and slow types (not applicable with relay trip). ## **Types** - Specity rated current, time delay curve, or voltage trip coil voltage in place of 6 7 8 in the Ordering Type No. **==> picture [435 x 426] intentionally omitted <==** **----- Start of picture text -----**<br> Code<br>Internal No. of Inertia Auxiliary Contact<br>Circuit Poles Delay Alarm Contact Ordering Type No. Applicable Standards 6 Rated 7 Time Delay 8 Voltage Trip<br>Current Curve Coil Voltage<br>— NC1V-1100- 6 7<br>– One Auxiliary Contact NC1V-1111- 6 7<br>One Alarm Contact NC1V-1121 6 7<br>1-pole<br>— NC1V-1100F- 6 7<br>With One Auxiliary Contact NC1V-1111F- 6 7<br>One Alarm Contact NC1V-1121F- 6 7<br>— NC1V-2100- 6 7<br>One Auxiliary Contact NC1V-2111- 6 7<br>— Two Auxiliary Contacts NC1V-2112- 6 7<br>One Alarm Contact NC1V-2121- 6 7<br>One Auxiliary Contact and One Alarm Contact NC1V-2131- 6 7<br>2-pole<br>— NC1V-2100F- 6 7<br>0.1A<br>One Auxiliary Contact NC1V-2111F- 6 7 0.3A<br>With Two Auxiliary Contacts NC1V-2112F- 6 7 0.5A1A<br>One Alarm Contact NC1V-2121F- 6 7 2A<br>3A M (slow)<br>(Current Trip)Series Trip One Auxiliary Contact and One Alarm Contact NC1V-2131F- 6 7 5A7A A (medium)S (instantaneous) —<br>— NC1V-3100- 6 7 10A15A<br>One Auxiliary Contact NC1V-3111- 6 7 20A25A<br>Two Auxiliary Contacts NC1V-3112- 6 7 30A<br>— Three Auxiliary Contacts NC1V-3113- 6 7<br>One Alarm Contact NC1V-3121- 6 7<br>One Auxiliary Contact and One Alarm Contact NC1V-3131- 6 7<br>Two Auxiliary Contacts and One Alarm Contact NC1V-3132- 6 7<br>3-pole<br>— NC1V-3100F- 6 7<br>One Auxiliary Contact NC1V-3111F- 6 7<br>Two Auxiliary Contacts NC1V-3112F- 6 7<br>With Three Auxiliary Contacts NC1V-3113F- 6 7<br>One Alarm Contact NC1V-3121F- 6 7<br>One Auxiliary Contact and One Alarm Contact NC1V-3131F- 6 7<br>Two Auxiliary Contacts and One Alarm Contact NC1V-3132F- 6 7<br>1-pole NC1V-1500- 8<br>Relay Trip 2-pole — — NC1V-2500- 8 — — DC24V<br>(Voltage Trip)<br>3-pole NC1V-3500- 8<br>**----- End of picture text -----**<br> Note: Inertia delay is for AC circuit. Also, time delay curve of S (instantaneous) is not available with inertia delay. 5 NC1V Circuit Protectors ## **Internal Circuit** ## • **1-pole** **==> picture [434 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> NC1V-1100 NC1V-1111 NC1V-1121 NC1V-1500<br>(Without auxiliary/alarm contacts) (With auxiliary contact) (With alarm contact) (Relay Trip)<br>LINE LINE One auxiliary contact. LINE One alarm contact.<br>A<br>B<br>C<br>D<br>C N N C N N<br>LOAD LOAD O C LOAD O C<br>**----- End of picture text -----**<br> ## • **2-pole** **==> picture [434 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> NC1V-2100 NC1V-2111 NC1V-2121 NC1V-2500<br>(Without auxiliary/alarm contacts) (With auxiliary contact) (With alarm contact) (Relay Trip)<br>One auxiliary contact. One alarm contact.<br>Also available with two Also available with one<br>LINE LINE LINE LINE auxiliary contacts. LINE LINE auxiliary contact and<br>one alarm contact. A A<br>B B<br>C C<br>LOAD LOAD LOAD LOAD C NO NC LOAD LOAD C ON NC D D<br>**----- End of picture text -----**<br> Note: Those with two auxiliary contacts and with one auxiliary contact and one alarm contact have been applied for UL and CCC. ## • **3-pole** **==> picture [434 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> NC1V-3100 NC1V-3111 NC1V-3121 NC1V-3500<br>(Without auxiliary/alarm contacts) (With auxiliary contact) (With alarm contact) (Relay Trip)<br>One auxiliary contact. Also available One alarm contact. Also available with one<br>with two or three auxiliary contacts. auxiliary and one alarm contacts, and two<br>auxiliary and one alarm contacts.<br>LINE LINE LINE LINE LINE LINE LINE LINE LINE<br>A A A<br>B B B<br>C C C<br>LOAD LOAD LOAD LOAD LOAD LOAD C NO NC LOAD LOAD LOAD C NO NC D D D<br>**----- End of picture text -----**<br> Note: Those with two or three auxiliary contacts, with one auxiliary contact and one alarm contact, and with two auxiliary contacts and one alarm contacts have been applied for UL and CCC. ## **Overcurrent-Time Delay Characteristics (sec at 40°C) [vertical mounting]** **==> picture [434 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> Percent of Rated Current<br>Item Time Delay Curve<br>100% 125% 150% 175% 200% 400% 600% 800% 1000%<br>S (instantaneous) NO TRIP — ∗to 0.10.005 to 0.060.003 to 0.050.0027 to 0.030.002 to 0.0280.002 to 0.0250.002 to 0.0220.002<br>AC (50/60 Hz)/DC A (medium) NO TRIP ∗25 to 240 16 to 140 — 6 to 32 0.4 to 4 0.0055 to 1.5 to 0.80.004 to 0.650.004<br>M (slow) NO TRIP ∗60 to 600 30 to 200 — 9 to 60 0.4 to 10 to 4.50.006 to 1.80.004 to 0.80.004<br>With Inertia Delay NO TRIP 25 to 240 — — 6 to 32 0.8 to 6 0.09 0.02 0.01<br>A (medium) to 3.5 to 1.8 to 1.0<br>AC (50/60 Hz)<br>With Inertia Delay NO TRIP 60 to 600 — — 10 to 60 0.8 to 10 0.06 0.02 0.01<br>M (slow) to 4.5 to 3 to 1.75<br>**----- End of picture text -----**<br> ∗: MAY TRIP on DC 6 NC1V Circuit Protectors ## **Time Delay Curves at 40°C** **==> picture [434 x 613] intentionally omitted <==** **----- Start of picture text -----**<br> 1000 1000<br>DC (Note) Curve A DC (Note) Cu rve M<br>100 AC (medium) 100 AC (slow)<br>10 10<br>1 1<br>0.1 0.1<br>0.01 0.01<br>100 200 300 400 500 600 700 800 900 1000 100 200 300 400 500 600 700 800 900 1000<br>125 125<br>Current (percent load of the rated current) Current (percent load of the rated current)<br>1000<br>Curve S Note: The entire shaded area applies to AC.<br>DC (Note) (instantaneous) For DC, the shaded area on the right of the dashed line applies.<br>100<br>10<br>1<br>AC<br>0.1<br>0.01<br>100 200 300 400 500 600 700 800 900 1000<br>125<br>Current (percent load of the rated current)<br>1000 1000<br>Curve A Curve M<br>(medium) (slow)<br>With Inertia Delay With Inertia Delay<br>100 100<br>10 10<br>1 1<br>0.1 0.1<br>0.01 0.01<br>100 200 300 400 500 600 700 800 900 1000 100 200 300 400 500 600 700 800 900 1000<br>125 125<br>Current (percent load of the rated current) Current (percent load of the rated current)<br>Time in sec<br>Time in sec<br>Time in sec<br>Time in sec Time in sec<br>**----- End of picture text -----**<br> 7 NC1V Circuit Protectors ## **Time Delay Curve and Ambient Temperature** NC1V circuit protectors employ an electromagnetic tripping system, where the rated current (trip current) is not affected by ambient temperatures. But the time delay may vary with the oil viscosity in the oil dash pot. Lower oil viscosity at higher temperatures results in a shorter delay, whereas at lower temperatures the delay will be longer. ## **Temperature Correction Curve** The time delay curves on the preceding page are measured at 40°C. With reference to the following curves, time delays can be corrected according to ambient temperature. **==> picture [132 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> 600<br>500<br>400<br>300<br>200<br>100<br> 80<br> 60<br> 40<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient Temperature (°C)<br>Change of Time Delay (%)<br>**----- End of picture text -----**<br> The time delay is based on an ambient temperature of 40°C. Time delays at other temperatures are corrected according to the temperature correction curve. The time delay of the instantaneous time delay curve (S) is not affected by the ambient temperature. ## **Inertia Delay** Inertia delay is designed not to trip on a non-repeating single pulse of 20 times the rated current (peak value) for a duration of 8 ms. In addition, circuit protectors equipped with inertia delay do not respond to high inrush currents caused by transformer or lamp loads, but perform the specified interruption on the subsequent overcurrents. Inertia delay is available on AC circuits, and is not available with the series trip curve S (instantaneous). **==> picture [174 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> 12000<br>1. Percent of rated current<br> Pulse peak current ×100<br> Protector rated current<br>10000 2. Sinusoidal or parabolic pulse<br>Pulse peak current<br> 8000<br>Pulse width (Duration)<br> 6000<br> 4000<br> 2000<br>1 2 3 4 5 6 7 8 9 10<br>Pulse Width (ms)<br>Percent of Rated Current (%)<br>**----- End of picture text -----**<br> |||| |---|---|---| |When operating temperature<br>exceeds 40°C, derate the rated<br>current by multiplying the derating<br>factor shown on the right.|Operating<br>Temp.|Derating<br>Factor| ||50°C|0.9| ||55°C|0.8| ||60°C|0.7| ## **Impedance and Coil Resistance** - **Series Trip (Current Trip)** at 25°C **==> picture [211 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> For AC 50/60 Hz For DC<br>Rated Impedance (Ω) Resistance (Ω)<br>Current<br>Curve S Curves A, M Curve S Curves A, M<br>0.1A 66.0 116.0 43.0 106.0<br>0.3A 6.6 11.0 4.1 10.0<br>0.5A 1.92 3.65 0.86 3.40<br>1A 0.50 0.93 0.25 0.90<br>2A 0.16 0.27 0.11 0.25<br>3A 0.07 0.12 0.050 0.11<br>5A 0.025 0.050 0.015 0.045<br>7A 0.014 0.027 0.011 0.025<br>10A 0.007 0.021 0.005 0.020<br>15A 0.006 0.010 0.005 0.009<br>20A 0.005 0.006 0.004 0.005<br>25A 0.004 0.005 0.004 0.005<br>30A 0.003 0.004 0.003 0.004<br>**----- End of picture text -----**<br> ## **Voltage Drop Due to Coil Resistance or Impedance** The internal resistance or impedance of a circuit protector tends to be larger for a smaller rated current. Therefore, when circuit protectors of a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, which should also be considered during installation. Tolerance: ±25% (up to 20A), ±50% (25A and 30A) • **Relay Trip (Voltage Trip)** at 25°C For DC Tripping Voltage Resistance (Ω) 24-48V 100.0 Tolerance: ±25% 8 NC1V Circuit Protectors ## **Dimensions** **==> picture [33 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> • 1-pole<br>**----- End of picture text -----**<br> **==> picture [434 x 441] intentionally omitted <==** **----- Start of picture text -----**<br> All dimensions in mm.<br>DIN Rail (BNDN1000)<br>M4 Terminal Screw<br>12.0 (up to 20A) 6.6 66.0<br>M5 Terminal Screw 48.3<br>(25A or more)<br>NC1V-1100<br>ON<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>17.5 33.0<br>DIN Rail (BNDN1000)<br>12.0 M4 Terminal Screw(up to 20A)M5 Terminal Screw 6.6 66.0 48.3 (M4 Mounting Screws)Mounting Hole Layout<br>(25A or more)<br>12<br>NC1V-1111<br>(Auxiliary Contact)<br>NC1V-1121<br>(Alarm Contact) ON<br>M3.5 Terminal Screw<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>17.5 Terminal Cover 33.0<br>DIN Rail (BNDN1000)<br>12.0 6.6 66.0<br>48.3<br>M5 Terminal Screw (30A)<br>NC1V-1500<br>(Relay Trip) ON<br>M3.5 Terminal Screw<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>17.5 Terminal Cover 33.0<br>2-M4<br>71.4 56.0 72.5 44.0<br>78.8<br>71.4 56.0 72.5 48.4 78.8<br>71.4<br>71.4 56.0 72.5 48.4<br>78.8<br>**----- End of picture text -----**<br> ## • **2-pole** **==> picture [434 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> M4 Terminal Srew DIN Rail (BNDN1000) Mounting Hole Layout<br>29.5 (up to 20A) 6.6 66.0 (M4 Mounting Screws)<br>M5 Terminal Screw 48.3<br>(25A or more) 29.5<br>NC1V-2100<br>ON<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>35.0 33.0<br>2-M4<br>71.4 560. 72.5 44.0<br>78.8<br>71.4<br>**----- End of picture text -----**<br> 9 NC1V Circuit Protectors ## • **2-pole** **==> picture [427 x 289] intentionally omitted <==** **----- Start of picture text -----**<br> DIN Rail (BNDN1000)<br>M4 Terminal Screw<br>29.5 (up to 20A) 6.6 66.0<br>M5 Terminal Screw 48.3<br>NC1V-2111 (25A or more)<br>(one auxiliary contact)<br>NC1V-2112<br>(two auxiliary contacts)<br>NC1V-2121<br>(one alarm contact) ON<br>NC1V-2131<br>(one auxiliary contact<br>and one alarm contact) M3.5 Terminal Screw Mounting Hole Layout<br>2-ø4.5 Holes (M4 Mounting Screws)<br>(for screw mounting) 5.0<br>35.0 Terminal Cover 33.0 29.5<br>The dimensions are for NC1V-2111 and NC1V-2121.<br>DIN Rail (BNDN1000)<br>29.5 6.6 66.0<br>48.3<br>M5 Terminal Screws (30A)<br>NC1V-2500<br>(Relay Trip) ON<br>M3.5 Terminal Screw<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>35.0 Terminal Cover 33.0<br>2-M4<br>71.4 56.0 72.5 48.4 78.8<br>71.4<br>71.4 56.0 72.5 48.4<br>78.8<br>**----- End of picture text -----**<br> ## • **3-pole** **==> picture [429 x 288] intentionally omitted <==** **----- Start of picture text -----**<br> DIN Rail (BNDN1000)<br>M4 Terminal Screw<br>47.0 (up to 20A) 6.6 66.0<br>M5 Terminal Srew 48.3<br>(25A or more)<br>NC1V-3100<br>ON<br>Mounting Hole Layout<br>(M4 Mounting Screws)<br>47.0<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>52.5 33.0<br>NC1V-3111 M4 Terminal Screw DIN Rail (BNDN1000)<br>(one auxiliary contact) 47.0 (up to 20A) 6.6 66.0<br>NC1V-3112 M5 Terminal Srew(25A or more) 48.3<br>(two auxiliary contacts)<br>NC1V-3113<br>(three auxiliary contacts)<br>NC1V-3121<br>(one alarm Contact) ON<br>NC1V-3131<br>(one auxiliary contact<br>and one alarm contact) M3.5 Terminal Srew<br>NC1V-3132 2-ø4.5 Holes<br>and one alarm contact)(two auxiliary contacts 52.5 (for screw mounting) Terminal Cover 33.05.0<br>The dimensions are for NC1V-3111 and NC1V-3121.<br>2-M4<br>71.4 56.0 72.5 44.0 887.<br>71.4<br>71.4 56.0 72.5 48.4<br>78.8<br>**----- End of picture text -----**<br> 10 NC1V Circuit Protectors ## • **3-pole** **==> picture [434 x 332] intentionally omitted <==** **----- Start of picture text -----**<br> • All dimensions in mm.<br>DIN Rail (BNDN1000)<br>47.0 6.6 66.0 Mounting Hole Layout<br>48.3 (M4 Mounting Screws)<br>M5 Terminal Screw (30A) 47.0<br>NC1V-3500<br>(Relay Trip) ON<br>M3.5 Terminal Screw<br>2-ø4.5 Holes<br>(for screw mounting) 5.0<br>52.5 Terminal Cover 33.0<br>Instructions<br>• Installation Angle • Applicable Wire and Crimp Terminal<br>Tripping method is hydraulic magnetic. Minimum operating Terminal Terminal Screw Connectable Wire Size ApplicableCrimping Tightening Torque<br>current varies with installation angle. Operating currents (mm [2] ) Terminal (N·m)<br>are influenced by the weight of movable iron core. With Spring-up, fingersafe, 0.25 to 1.65 R1.25-4<br>reference to the following figures, correct the rated current. slotted Phillips screw 1.04 to 2.63 R2-4 1 to 1.4<br>with square washer<br>(up to 20A) 2.63 to 6.64 R5.5-4<br>Spring-up fingersafe 0.25 to 1.65 R1.25-5<br>100% terminal 1.04 to 2.63 R2-5 1.8 to 2.2<br>(25A and 30A) 2.63 to 6.64 R5.5-5<br>0.25 to 1.65 R1.25-3.5<br>Slotted Phillips screw 0.7 to 0.9<br>with square washer<br>1.04 to 2.63 R2-3.5<br>• For wiring the main circuit terminal, use the applicable crimp terminals and<br>tighten to the recommended torque.<br>2-M4<br>71.4 56.0 72.5 48.4<br>78.8 71.4<br>Main Circuit Terminals<br>Terminals<br>Alarm Contact Voltage Coil<br>Auxiliary Contact<br>**----- End of picture text -----**<br> **==> picture [148 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>120% 90%<br>100%<br>**----- End of picture text -----**<br> - When using the NC1V circuit protector as CSA-certified product, use with CSAcertified crimp terminal. - When using the NC1V circuit protector as UL-listed product, use with UL-listed crimp terminal. ## **Panel Mounting Screw (not supplied)** **==> picture [175 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> Srew Type Tightening Torque Shape<br>Spring Washer<br>M4 0.8 to 1.0 N·m<br>Plain Washer<br>**----- End of picture text -----**<br> Minimum operating current is calculated from the following formula: ## **Product Markings (Example: NC1V-1111-30AA)** (Minimum operating current) = (Rated current) × (Correction factor by installation angle) × (Reference minimum tripping current rate) **==> picture [195 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> PSE Certification<br>Type No.<br>Rated Voltage 220VACPES J E T30A I.C.2500A No. of Poles<br>Rated Current NC1V-1111Ue 250VAC 50/60Hz · 65VDCIn 30A CIRCUIT PROTECTORCURVE APOLE 1 Time Delay CurveAuxiliary/Alarm Contact Rating<br>Suppl. Prot. 125VAC 3AAUX. SW Reference Operating<br>30 VDC 2A Temperature<br>A.T. 40°CJAPAN<br>Certification Marks<br>LOAD LINE<br>**----- End of picture text -----**<br> ## • **DIN Rails** - [Installation on DIN Rail] 1. Fasten the DIN rail securely. 2. With the latch facing downward, install the NC1V circuit protector on the DIN rail as shown below. [Removal from DIN Rail] ## **Installation of Auxiliary/Alarm Terminal Cover** Using a flat screwdriver, pull the latch on the circuit protector to remove from the DIN rail. After wiring the terminals, install the terminal cover by aligning with the circuit protector as shown below. **==> picture [189 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> Installing Removing<br>35mm-wide 35mm-wide<br>DIN Rail DIN Rail<br>Push<br>Flat<br>Srcrewdriver<br>Latch<br>**----- End of picture text -----**<br> **==> picture [54 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal cover installed<br>**----- End of picture text -----**<br> 11 NC1V Circuit Protectors ## **Accessories** ## • **DIN Rail** **==> picture [425 x 218] intentionally omitted <==** **----- Start of picture text -----**<br> F<br>35mm-wide DIN Rails<br>G H A<br>K B D<br>C<br>He<br>H<br>— Overall length 39.4" (1000mm) J ab<br>Length Part No. Material<br>1000mm BNDN1000 Aluminum<br>[1 -—J<br>• End Clip<br>Part No. Applicable Rail Material Package Quantity<br>Galvanized Trivalent<br>BNL6 BNDN1000 10<br>Chromate Treatment<br>9mm wide Se S S<br>**----- End of picture text -----**<br> - **Auxiliary/Alarm Terminal Cover** **==> picture [208 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> Type No. Material Package Quantity<br>NC1V-AUX-CV Nylon (PA66) 1<br>[_<br>**----- End of picture text -----**<br> - **Miscellaneous Accessories** (available 2009) |Type No.|Description| |---|---| |NC9Z-MA11|Panel Cut-Out Mountingbracket for 1-pole mode| |NC9Z-MA21|Panel Cut-Out Mountingbracket for 2-pole model| |NC9Z-MA31|Panel Cut-Out Mountingbracket for 3-pole model| |NC9Z-TA1|Fast-On Tab terminal Adapter| |NC9Z-PW1|MarkingPlate| |NC9Z-LK1|Lock-Out Bracket| Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: products@idec.co.jp IDEC CORPORATION (USA) IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD. Mipec 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA ~~ecm~~ Wendenstrasse 331, 20537 Hamburg, Germany Units 11-15, Level 27, Tower 1, Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 Millennium City 1, 388 Kwun Tong Road, Fax: +1-408-744-9055 / (800) 635-6246 E-mail: service@idec.de Kwun Tong, Kowloon, Hong Kong E-mail: opencontact@idec.comIDEC CANADA LIMITED IDEC (SHANGHAI) CORPORATIONRoom 608-609, 6F, Gangtai Plaza, No. 700, Tel: +852-2803-8989, Fax: +852-2565-0171E-mail: info@hk.idec.com 3155 Pepper Mill Court, Unit 4, Mississauga, Yan'an East Road, Shanghai 200001, PRC IDEC TAIWAN CORPORATION Ontario, L5L 4X7, Canada Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 8F-1, No. 79, Hsin Tai Wu Road, Sec. 1, Tel: +1-905-890-8561, Toll Free: (888) 317-4332 E-mail: idec@cn.idec.com Hsi-Chih, Taipei County, Taiwan Fax: +1-905-890-8562E-mail: sales@ca.idec.com IDEC (BEIJING) CORPORATIONRoom 211B, Tower B, The Grand Pacific Building, Tel: +886-2-2698-3929, Fax: +886-2-2698-3931E-mail: service@tw.idec.com IDEC AUSTRALIA PTY. LTD. 8A Guanghua Road, Chaoyang District, IDEC IZUMI ASIA PTE. LTD. 2/3 Macro Court, Rowville, Victoria 3178, Australia Beijing 100026, PRC No. 31, Tannery Lane #05-01, Tel: +61-3-9763-3244, Toll Free: 1800-68-4332 Tel: +86-10-6581-6131, Fax: +86-10-6581-5119 HB Centre 2, Singapore 347788 Fax: +61-3-9763-3255E-mail: sales@au.idec.com IDEC (SHENZHEN) CORPORATIONUnit AB-3B2, Tian Xiang Building, Tian’an Cyber Park, Tel: +65-6746-1155, Fax: +65-6844-5995E-mail: info@sg.idec.com IDEC ELECTRONICS LIMITED Fu Tian District, Shenzhen, Guang Dong 518040, PRC Unit 2, Beechwood, Chineham Business Park, Tel: +86-755-8356-2977, Fax: +86-755-8356-2944 Basingstoke, Hampshire RG24 8WA, UK Tel: +44-1256-321000, Fax: +44-1256-327755 www.idec.com E-mail: sales@uk.idec.com Cat. No. NC9Y-B100-0 PRINTED IN U.S.A. 5K 09/08
Updated at February 9, 2023
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →