MY2IN-D2 DC24
Power Relay, Miniature, DPDT, 24 VDC, 10 A, MY Series, Socket
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Power Relays
- Contact Configuration:DPDT; Coil Voltage:24VDC; Contact Current:10A; Product Range:MY Series; Relay Mounting:Socket; Coil Type:-; Contact Voltage VAC:250V; Relay Terminals:Quick Co
- Coil Type: -
- Coil Voltage: 24VDC
- Product Range: MY Series
- Relay Mounting: Socket
- Coil Resistance: 636ohm
- Contact Current: 10A
- Relay Terminals: Quick Connect, Solder
- Contact Material: Silver
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 125V
- Approvals & Standards: CE, CSA, UL
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 10.93 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **General-purpose Relay MY New model**
## **Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications**
- Models with lockable test buttons now available.
- Many variations possible through a selection of operation indicators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc.
- Arc barrier standard on 4-pole Relays.
- Dielectric strength: 2,000 VAC (coil to contact)
- Environment-friendly cadmium-free contacts.
- Safety standard approvals obtained.
## LR
- Wide range of Sockets (PY, PYF Series) and optional parts are available.
- Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A
- Provided with nameplate.
## **Orderin Information g**
## ■ **Relays**
## **Standard Coil Polarity**
|**Type**|**Contact form**|**Plug-in socket/Solder terminals**|**Plug-in socket/Solder terminals**|**Without LED indicator**|
|---|---|---|---|---|
|||**Standard with LED indicator**|**With LED indicator and**<br>**lockable test button**||
|Standard|DPDT|MY2N|MY2IN|MY2|
||4PDT|MY4N|MY4IN|MY4|
||4PDT (bifurcated)|MY4ZN|MY4ZIN|MY4Z|
|With built-in diode<br>(DC only)|DPDT|MY2N-D2|MY2IN-D2|---|
||4PDT|MY4N-D2|MY4IN-D2|---|
||4PDT (bifurcated)|MY4ZN-D2|MY4ZIN-D2|---|
|With built-in CR<br>(220/240 VAC, 110/120 VAC<br>only)|DPDT|MY2N-CR|MY2IN-CR|---|
||4PDT|MY4N-CR|MY4IN-CR|---|
||4PDT (bifurcated)|MY4ZN-CR|MY4ZIN-CR|---|
## **Reverse Coil Polarity**
|**Type**|**Contact form**|**Plug-in socket/Solder terminals**|**Plug-in socket/Solder terminals**|
|---|---|---|---|
|||**With LED indicator**|**With LED indicator and**<br>**lockable test button**|
|Standard (DC only)|DPDT|MY2N1|MY2IN1|
||4PDT|MY4N1|MY4IN1|
||4PDT (bifurcated)|MY4ZN1|MY4ZIN1|
|With built-in diode<br>(DC only)|DPDT|MY2N1-D2|MY2IN1-D2|
||4PDT|MY4N1-D2|MY4IN1-D2|
||4PDT (bifurcated)|MY4ZN1-D2|MY4ZIN1-D2|
**Note:** When ordering, add the rated coil voltage and “(s)” to the model number. Rated coil voltages are given in the coil ratings table.
Example: MY2 6VAC (S) Fo LL New model Rated coil voltage
General-purpose Relay **MY New model**
1
## ■ **Accessories (Order Separately)**
## **Sockets**
|**Poles**|**Front-mounting**<br>**Socket (DIN-track/**<br>**screw mounting)**|**Back-mounting Socket**|**Back-mounting Socket**|**Back-mounting Socket**|**Back-mounting Socket**|**Back-mounting Socket**|
|---|---|---|---|---|---|---|
|||**Solder terminals**||**Wire-wrap terminals**||**PCB terminals**|
|||**Without clip**|**With clip**|**Without clip**|**With clip**||
|2|PYF08A-E<br>PYF08A-N|PY08|PY08-Y1|PY08QN<br>PY08QN2|PY08QN-Y1<br>PY08QN2-Y1|PY08-02|
|4|PYF14A-E<br>PYF14A-N|PY14|PY14-Y1|PY14QN<br>PY14QN2|PY14QN-Y1<br>PY14QN2-Y1|PY14-02|
## **- Socket Hold down Clip Pairing**
|**Relay type**|**Poles**|**Front-connecting Socket (DIN-track/**<br>**screw mounting)**|**Front-connecting Socket (DIN-track/**<br>**screw mounting)**|**Front-connecting Socket (DIN-track/**<br>**screw mounting)**|**Back-connecting Socket**|**Back-connecting Socket**|**Back-connecting Socket**|**Back-connecting Socket**|**Back-connecting Socket**|**Back-connecting Socket**|
|---|---|---|---|---|---|---|---|---|---|---|
||||||**Solder/Wire-wrap terminals**|||**PCB terminals**|||
|||**Socket**||**Clip**|**Socket**||**Clip**|**Socket**||**Clip**|
|Without 2-pole test<br>button|2|PYF08A-E<br>PYF08A-N||PYC-A1|PY08(QN)||PYC-P<br>PYC-P2|PY08-02||PYC-P<br>PYC-P2|
||4|PYF14A-E<br>PYF14A-N|||PY14(QN)|||PY14-02|||
|2-pole test button|2|PYF08A-E<br>PYF08A-N||PYC-E1|PY08(QN)||PYC-P2|PY08-02||PYC-P2|
|**Mounting Plates for Sockets**|||||||||||
|**Socket model**|||**For 1 Socket**|||**For 18 Sockets**|||**For 36 Sockets**||
|PY08, PY08QN(2), PY14, PY14QN(2)|||PYP-1|||PYP-18|||PYP-36||
**Note:** PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets.
## **Track and Accessories**
|**Track and Accessories**||
|---|---|
|**Supporting Track (length = 500 mm)**|PFP-50N|
|**Supporting Track (length = 1,000 mm)**|PFP-100N, PFP-100N2|
|**End Plate**|PFP-M|
|**Spacer**|PFP-S|
## **S ecifications p**
## ■ **Coil Ratings**
|**Rated voltage**|**Rated voltage**|**Rated current**|**Rated current**|**Coil**<br>**resistance**|**Coil inductance**<br>**(reference value)**|**Coil inductance**<br>**(reference value)**|**Must**<br>**operate**<br>**voltage**|**Must**<br>**release**<br>**voltage**|**Max.**<br>**voltage**|**Power**<br>**consumption**<br>**(approx.)**|
|---|---|---|---|---|---|---|---|---|---|---|
|||**50 Hz**|**60 Hz**||**Arm. OFF**|**Arm. ON**|**% of rated voltage**||||
|AC|6 V*|214.1 mA|183 mA|12.2Ω|0.04 H|0.08 H|80% max.|30% min.|110%|1.0 to 1.2 VA<br>(60 Hz)|
||12 V|106.5 mA|91 mA|46Ω|0.17 H|0.33 H|||||
||24 V|53.8 mA|46 mA|180Ω|0.69 H|1.30 H|||||
||48/50 V*|24.7/<br>25.7 mA|21.1/<br>22.0 mA|788Ω|3.22 H|5.66 H|||||
||110/120 V|9.9/10.8 mA|8.4/9.2 mA|4,430Ω|19.20 H|32.1 H||||0.9 to 1.1 VA<br>(60 Hz)|
||220/240 V|4.8/5.3 mA|4.2/4.6 mA|18,790Ω|83.50 H|136.4 H|||||
|DC|6 V*|151 mA||39.8Ω|0.17 H|0.33 H||10% min.||0.9 W|
||12 V|75 mA||160Ω|0.73 H|1.37 H|||||
||24 V|37.7 mA||636Ω|3.20 H|5.72 H|||||
||48 V*|18.8 mA||2,560Ω|10.60 H|21.0 H|||||
||100/110 V|9.0/9.9 mA||11,100Ω|45.60 H|86.2 H|||||
- **Note: 1.** The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and ±15% for DC coil resistance.
**2.** Performance characteristic data are measured at a coil temperature of 23°C.
**3.** AC coil resistance and impedance are provided as reference values (at 60 Hz).
**4.** Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required.
**5.** Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative.
General-purpose Relay **MY New model**
2
## ■ **Contact Ratings**
|**Item**|**2-pole**|**2-pole**|**4-pole**|**4-pole**|**4-pole (bifurcated)**|**4-pole (bifurcated)**|
|---|---|---|---|---|---|---|
||**Resistive load**<br>**(cos**φ**= 1)**|**Inductive load**<br>**(cos**φ**= 0.4, L/R = 7 ms)**|**Resistive load**<br>**(cos**φ**= 1)**|**Inductive load**<br>**(cos**φ**= 0.4, L/R = 7 ms)**|**Resistive load**<br>**(cos**φ**= 1)**|**Inductive load**<br>**(cos**φ**= 0.4, L/R = 7 ms)**|
|Rated load|5A, 250 VAC<br>5A, 30 VDC|2A, 250 VAC<br>2 A, 30 VDC|3 A, 250 VAC<br>3 A, 30 VDC|0.8 A, 250 VAC<br>1.5 A, 30 VDC|3 A, 250 VAC<br>3 A, 30 VDC|0.8 A, 250 VAC<br>1.5 A, 30 VDC|
|Carry current|10 A (see note)||5 A (see note)||||
|Max. switching<br>voltage|250 VAC<br>125 VDC||250 VAC<br>125 VDC||||
|Max. switching<br>current|10 A||5 A||||
|Max. switching<br>power|2,500 VA<br>300 W|1,250 VA<br>300 W|1,250 VA<br>150 W|500 VA<br>150 W|1,250 VA<br>150 W|500 VA<br>150 W|
|Failure rate<br>(reference value)|5 VDC, 1 mA||1 VDC, 1 mA||1 VDC, 100µA||
**Note:** Don’t exceed the carry current of a Socket in use. Please see page 9.
## ■ **Characteristics**
|■**Characteristics**||
|---|---|
|**Item**|**All Relays**|
|**Contact resistance**|100 mΩmax.|
|**Operate time**|20 ms max.|
|**Release time**|20 ms max.|
|**Max. operating frequency**|Mechanical:<br>18,000 operations/hr<br>Electrical:<br>1,800 operations/hr (under rated load)|
|**Insulation resistance**|1,000 MΩmin. (at 500 VDC)|
|**Dielectric strength**|2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)|
|**Vibration resistance**|Destruction:<br>10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)<br>Malfunction:<br>10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)|
|**Shock resistance**|Destruction:<br>1,000 m/s2<br>Malfunction:<br>200 m/s2|
|**Endurance**|See the followingtable.|
|**Ambient temperature**|Operating: –55°C to 70°C (with no icing)|
|**Ambient humidity**|Operating: 5% to 85%|
|**Weight**|Approx. 35 g|
**Note:** The values given above are initial values.
## ■ **Endurance Characteristics**
|■**Endurance**|**Characteristics**||
|---|---|---|
|**Pole**|**Mechanical life (at 18,000 operations/hr)**|**Electrical life**<br>**(at 1,800 operations/hr under rated load)**|
|2-pole|AC:50,000,000 operations min.<br>DC:100,000,000 operations min.|500,000 operations min.|
|4-pole||200,000 operations min.|
|4-pole (bifurcated)|20,000,000 operations min.|100,000 operations min.|
General-purpose Relay **MY New model**
3
## ■ **Approved Standards**
## **VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435)**
|**No. of poles**|**Coil ratings**|**Contact ratings**|**Operations**|
|---|---|---|---|
|2|6, 12, 24, 48/50, 100/110<br>110/120, 200/220,<br>220/240 VAC<br>6, 12, 24, 48, 100/110,<br>125 VDC|10 A, 250 VAC (cosφ=1)<br>10 A, 30 VDC (L/R=0 ms)|10 x 103|
|4||5 A, 250 VAC (cosφ=1)<br>5 A, 30 VDC (L/R=0 ms)|100 x 103<br>MY4Z AC; 50 x 103|
## **UL508 Recognitions (File No. 41515)**
|**No. ofpoles**|**Coil ratings**|**Contact ratings**|**Operations**|
|---|---|---|---|
|2|6 to 240 VAC<br>6 to 125 VDC|10 A, 30 VDC (General purpose)<br>10 A, 250 VAC(Generalpurpose)|6 x 103|
|4||5 A, 250 VAC (General purpose)<br>5 A, 30 VDC(Generalpurpose)||
|**CSA C22.2 No. 14 Listings (File No. LR31928)**||||
|||||
|**No. ofpoles**|**Coil ratings**|**Contact ratings**|**Operations**|
|2|6 to 240 VAC<br>6 to 125 VDC|10 A, 30 VDC<br>10 A, 250 VAC|6 x 103|
|4||5 A, 250 VAC (Same polarity)<br>5 A, 30 VDC(Samepolarity)||
|**IMQ (File No. EN013 to 016)**||||
|**No. of poles**|**Coil ratings**|**Contact ratings**|**Operations**|
|2|6, 12, 24, 48/50, 100/110<br>110/120, 200/220,<br>220/240 VAC<br>6, 12, 24, 48, 100/110,<br>125 VDC|10 A, 30 VDC<br>10 A, 250 VAC|10 x 103|
|4||5 A, 250 VAC<br>5 A, 30 VDC|100 x 103<br>MY4Z AC; 50 x 103|
## **LR Recognitions (File No. 98/10014)**
|**No. ofpoles**|**Coil ratings**|**Contact ratings**|**Operations**|
|---|---|---|---|
|2|6 to 240 VAC<br>6 to 125 VDC|10 A, 250 VAC (Resistive)<br>2 A, 250 VAC (PF0.4)<br>10 A, 30 VDC (Resistive)<br>2 A, 30 VDC(L/R=7 ms)|50 x 103|
|4||5 A, 250 VAC (Resistive)<br>0.8 A, 250 VAC (PF0.4)<br>5 A, 30 VDC (Resistive)<br>1.5 A, 30 VDC(L/R=7 ms)|50 x 103|
## **SEV Listings (File No. 99.5 50902.01)**
|**No. of poles**|**Coil ratings**|**Contact ratings**|**Operations**|
|---|---|---|---|
|2|6 to 240 VAC<br>6 to 125 VDC|10 A, 250 VAC<br>10 A, 30 VDC|10 x 103|
|4||5 A, 250 VAC<br>5 A, 30 VDC|100 x 103<br>MY4Z AC; 50 x 103|
General-purpose Relay **MY New model**
4
**En ineerin Data g g**
## **Maximum Switching Power**
**==> picture [403 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY2 MY4, MY4Z<br>30CoonPn AC resistive load 1 30 aLTA TTTOn ee<br>AC inductive load<br>i (cosφ=0.4) ee el AC resistive load<br>a) ee | ee AC inductive load<br>5 SSeSEHH SSEe Sas.eee ee ‘05SSsss See S eetis ott (cosφ=0.4)<br>3a ne<br>LCI oNHH DC resistive load ll 3 a<br>DC resistive load<br>AN\ MM sltuil|| eePY NT<br>0.5}SSS See aeaae, teil 0sSEEE S ee<br>DC inductive load DC inductive load<br>a Perr (L/R=7 ms) nhHS oa---4 (L/R=7 ms) YARis ae)<br>ot1 LULU TOU ETT olYt i IE CTHNeTEi<br>3°95 10 30 50 100 © 250 500 3 5 10 30 50 100 250 500<br>Switching voltage (V) Switching voltage (V)<br>Switching current (A) Switching current (A)<br>**----- End of picture text -----**<br>
## **Endurance**
## **MY2 (Resistive Loads)**
## **MY2 (Inductive Loads)**
**==> picture [406 x 340] intentionally omitted <==**
**----- Start of picture text -----**<br>
10000 ———<—<——<—<$_=—=$ — 10000 ————<br>5000 es ee oe 5000 es ee<br>3000 a es 250 VAC 3000 Ps 250 VAC es es ee<br>1000 AS 1000 Ls a 30 VDC<br>PNEZ | NY I<br>500 30 VDC 30 VDC 500<br>300 ee a 300 a 30 VDC lS ~a<br>>.<.) cn eo [PP] 250 VAC<br>100 ee 250 VAC e 100 aw<br>50 a 50 ES OL Ss Ceres<br>30 30<br>-—+——+—_ + + a<br>10 ee ee 10 a ee<br>ié} 2 4 6 8 10 0 1 2 3 4 5<br>Switching current (A) Switching current (A)<br>MY4 (Resistive Loads) MY4 (Inductive Loads)<br>10000 | 10000 — ———————<br>5000 aot 5000 ae ee ee<br>a ee<br>3000 250 VAC 3000<br>ee ee ee ee es ee ee<br>30 VDC<br>1000 1000<br>————eEE— PN<br>500300 ee— a Cre 30 VDC 500300 o ———e 30 VDC<br>30 VDC<br>i. ” A PZ [tsa |<br>250 VAC<br>100 e e 100 N/T<br>= eS ———aS 250 VAC {awe ee ——SS———EE——EE—esee 250 VAC<br>50 50<br>e ee OS<br>30 30<br>a ee s e ee ee<br>10 10<br>0 1 2 3 4 5 0 0.5 1 1.5 2<br>Switching current (A) Switching current (A)<br>3 3<br>3 3<br>Endurance (x10 operations) Endurance (x10 operations)<br>Endurance (x10 operations) Endurance (x10 operations)<br>**----- End of picture text -----**<br>
## **MY4 (Resistive Loads)**
General-purpose Relay **MY New model**
5
**==> picture [422 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY4Z (Resistive Loads) MY4Z (Inductive Loads)<br>10000 _—— ES 10000 —>>===SS=SS==SS—<br>5000 5000<br>3000 3000<br>ee ee eeee<br>1000 1000<br>e————————— e 250 VAC J—————||<br>500 500 30 VDC<br>300 S S 300 —— —<br>30 VDC 30 VDC<br>100 R 30 VDC S 100 P/ 250 VAC h a<br>50 50<br>30 250 VAC 30<br>250 VAC<br>en ee ee a<br>10 10<br>Switching Current (A) Switching Current (A)<br>3 3<br>Endurance (x10 operations) Endurance (x10 operations)<br>**----- End of picture text -----**<br>
General-purpose Relay **MY New model**
6
## **Dimensions**
**Note:** All units are in millimeters unless otherwise indicated.
## **2-Pole Models**
**==> picture [24 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY2N<br>**----- End of picture text -----**<br>
## **4-Pole Models**
**==> picture [24 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY4N<br>**----- End of picture text -----**<br>
**==> picture [131 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.6<br>Eight, 1.2 dia. × 2.2 long holes<br>0.5<br>28 max.<br>is * * _<br>36 max. 6.4<br>21.5 max.<br>2.6<br>Eight, 1.2 dia. × 2.2 long holes<br>0.5<br>= 28 max.<br>a 36 max. 6.4 e<br>21.5 max.<br>**----- End of picture text -----**<br>
## **Models with Test Button**
**==> picture [26 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY2IN<br>**----- End of picture text -----**<br>
**==> picture [220 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pe 2.6<br>8 Eight, 1.2 dia. × 2.2 long holes<br>[|<br>28 max.<br>i<br>fer 14.2 36 max. roo<br>(1.417) —<br>21.5 max.<br>6.3<br>5<br>80.5<br>**----- End of picture text -----**<br>
**==> picture [26 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY4IN<br>**----- End of picture text -----**<br>
**==> picture [221 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.6<br>8 Fourteen, 1.2 dia. × 2.2 long holes<br>28 max.<br>PT et |<br>Som - 9] |<br>fe 14.2 36 max. |<br><1.417> 6.4 21.5 max.<br>6.3<br>0.5<br>5<br>80.5<br>**----- End of picture text -----**<br>
General-purpose Relay **MY New model**
7
## **Terminal Arrangement/Internal Connections (Bottom View)**
**==> picture [17 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY2<br>**----- End of picture text -----**<br>
**MY4(Z)**
**==> picture [457 x 485] intentionally omitted <==**
**----- Start of picture text -----**<br>
MY2N/MY2IN MY2N/MY2IN MY2N-D2/MY2IN-D2<br> (AC Models) (DC Models) (DC Models Only)<br>1 4 1 4 1 4 1 4<br>5 8 5 8 5 8 5 8<br>9 12 9 12 9 12 9 12<br>− + − +<br>13 14 13 14 13 14 13 14<br>MY2N-CR/MY2IN-CR MY2N1/MY2IN1 MY2N1-D2/MY2IN1-D2<br> (AC Models Only) (DC Models Only) (DC Models Only)<br>1 4 1 4 1 4<br>5 8 5 8 5 8<br>9 12 9 12 9 12<br>+ − + −<br>13 14 13 14 13 14<br>MY4(Z)N/MY4(Z)IN MY4(Z)N/MY4(Z)IN MY4(Z)N-D/MY4(Z)IN-D2<br> (AC Models) (DC Models) (DC Models Only)<br>1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4<br>5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8<br>9 10 11 12 9 10 11 12<br>− + − +<br>13 14 13 14 13 14 13 14<br>MY4(Z)N-CR/MY4(Z)IN-CR MY4(Z)N1/MY4(Z)IN1 MY4(Z)N1-D2/MY4(Z)IN1-D2<br> (AC Models Only) (DC Models Only) (DC Models Only)<br>**----- End of picture text -----**<br>
**==> picture [333 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 4 1 2 3 4 1 2 3 4<br>5 6 7 8 5 6 7 8 5 6 7 8<br>9 10 11 12<br>+ − + −<br>13 14 13 14 13 14<br>**----- End of picture text -----**<br>
**Note:** The DC models have polarity.
General-purpose Relay **MY New model**
8
## **Socket for MY**
## **Track-mounted (DIN Track) Socket Conforms to VDE 0106, Part 100**
- Snap into position along continuous sections of any mounting track.
- Facilitates sheet metal design by standardized mounting dimensions.
- Design with sufficient dielectric separation between terminals eliminates the need of any insulating sheet.
## ■ **Safety Standards for Sockets**
|**Model**|**Standards**|**File No.**|
|---|---|---|
|PYF08A-E, PYF08A-N<br>PYF14A-E, PYF14A-N|UL508|E87929|
||CSA22.2|LR31928|
## **Back-connecting Sockets**
## ■ **Specifications**
|**Item**|**Pole**|**Model**|**Carry current**|**Dielectric withstand**<br>**voltage**|**Insulation resistance**<br>**(see note 2)**|
|---|---|---|---|---|---|
|Screwless Clamp<br>Terminal Socket|2|PYF08S|10 A|2,000 VAC, 1 min|Less than 1,000 MΩ|
||4|PYF14S|5 A|||
|Track-mounted<br>Socket|2|PYF08A-E|7 A|2,000 VAC, 1 min|1,000 MΩmin.|
|||PYF08A-N (see note 3)|7 A (see note 4)|||
||4|PYF14A-E|5 A|||
|||PYF14A-N (see note 3)|5 A (see note 4)|||
|Back-connecting<br>Socket|2|PY08(-Y1)|7 A|1,500 VAC, 1 min|100 MΩmin.|
|||PY08QN(-Y1)||||
|||PY08-02||||
||4|PY14(-Y1)|3 A|||
|||PY14QN(-Y1)||||
|||PY14-02||||
- **Note: 1.** The values given above are initial values.
**2.** The values for insulation resistance were measured at 500 V at the same place as the dielectric strength.
**3.** The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C.
**4.** When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40°C, reduce the current to 60%.
**5.** The MY2(S) can be used at 70°C with a carry current of 7 A.
General-purpose Relay **MY New model**
9
## ■ **Dimensions**
**Note:** All units are in millimeters unless otherwise indicated.
|**Socket**|**Dimensions**|**Terminal arrangement/**<br>**Internal connections**<br>**(top view)**|**Mounting holes**|
|---|---|---|---|
|PYF08S|(5.3)<br>85 max.<br>38.2 max.<br>36.5 max.<br>23.2 max.<br>+—32.6—+|||---|
|PYF08A-E<br>ey|31 max.<br>23 max.<br>72 max.<br>Two, 4.2 x 5<br>mounting<br>holes<br>Eight, M3 x 8<br>sems screws<br>|<br>35.4<br>| bes<br>No|oe<br>s|°|(TOP VIEW)<br>Two, M3, M4, or 4.5-dia. holes<br>**Note:**Track mounting is also<br>possible. Refer to page<br>12 for supporting tracks.<br>|<br>‘<br>1<br>J|
|PYF08A-N|4<br>42<br>8<br>44<br>1<br>12<br>5<br>14<br>41<br>12<br>A2<br>14<br>11<br>9<br>A1<br>13<br>A2<br>14<br>PYF-08A-N<br>73<br>22 max.<br>67 max.<br>30 max.<br>~~=|~~<br>Py<br>~~a~~<br>|,|4<br>42<br>1<br>8<br>5<br>12<br>9<br>14<br>14<br>13<br>44<br>12<br>14<br>41<br>11<br>A2 A2 A1<br>db f|18.7<br>3.0 dia.<br>3.5 dia. or M3<br>**Note:**Track mounting is also<br>possible. Refer to page<br>12 for supporting tracks.<br>f~~T~~S|
General-purpose Relay **MY New model**
10
**==> picture [502 x 495] intentionally omitted <==**
**----- Start of picture text -----**<br>
Socket Dimensions Terminal arrangement/ Mounting holes<br>Internal connections<br>(top view)<br>PYF14S Pr 36.5 max.<br>31 max.<br>eA Fr -| braze (3.4) ' H<br>---<br>Be = | ck | CS irra |<br>85 max. ctf Gtk<br>=| 1 | Ar<br>(4.15) he I<br>PYF14A-E Two, 4.2 x 5 3.4<br>mounting Two, M3, M4, or 4.5-dia. holes<br>holes 8 Fourteen, M3 x 8<br>sems screws<br>eee < 72 max. oooc 35.4<br>c0ugf | '<br>Tey<br>4 a T Bee Note: Track mounting is also(TOP VIEW) a<br>29.5 max. 16.5 possible. Refer to page<br>12 for supporting tracks.<br>31 max.<br>PYF14A-N 42 32 22 12<br>—_ 4284 3327 2226 1125 444 O 343 242 141 Two, 4.5 dia. or M4<br>44 34 24 14 8 7 6 5<br>67 max.<br>tp Wo 4112 PYF-14A-N3111 o o 1021 119 73 Ss 26<br>14A2 A214 A113 12 11 10 9 Note: Track mounting is also<br>Can | E 41 31 21 11 possible. Refer to page<br>ali 29.5 max. h) 30 max. | i A214 A214 A113 12 for supporting tracks.<br>eT |<br>**----- End of picture text -----**<br>
General-purpose Relay **MY New model**
11
**==> picture [506 x 608] intentionally omitted <==**
**----- Start of picture text -----**<br>
Socket Dimensions Terminal arrangement/ Mounting holes<br>Internal connections<br>(bottom view)<br>PY08/PY08-Y1 (See note) Eight, 3 x 1.2 elliptical holes<br><itg pera areonnnnasy 4 —<br>25.5 max.<br>oe fp Sdebo--b-----42] | ci { 29.5 max.<br>20 max. 24 max.<br>42 max.<br>Note: The PY08-Y1 includes sections indicated by<br>dotted lines.<br>25,8192<br>PY08QN/<br>PY08QN-Y1<br>gS D prapescpccnnneags | rz<br>oC ae (See note) 29.5 max. o 6<br>41.5 max. 22 max.<br>| | i T e 42 max. 27 25 — _ 24 max. (9) ®<br>Note: The PY08QN-Y1 includes sections<br>indicated by dotted lines.<br>wif<br>PY08-02 on 0.3 ‘Tima,1.0 25.5 max. b : 132mam<br>29.5 max.<br>:<br>27 43 Lt 22 max. 2 64 [1 | _ Eight, 1.3-dia.<br>16.5 max. 4.2 holes<br>PY14/PY14-Y1 (See note) Fourteen, 3 x 1.2 elliptical holes<br>25.5 max.<br>29.5 max.<br>( 27 77 Ts<br>20 max. 24 max.<br>42 max.<br>Note: The PY14-Y1 includes sections indicated by<br>dotted lines.<br>PY14QN/<br>PY14QN-Y1<br>ban (See note) “1<br>29.5 max.<br>ni \ oo. 41.5 max. i ©6000<br>ale : ° oe 9000<br>42 max. 22 max.<br>24 max.<br>a iA — ® ©<br>Note: The PY14QN-Y1 includes sections<br>rt I indicated by dotted lines.<br>PY14-02<br>I 1.0 13.2 “4<br><a to3 KG 25.5 max.<br>29.5 max.<br>air ARIE 8666-4<br>PY = ee Looe 4 12.65<br>27 43 2 Lg’ gi<br>22 max.<br>16.5 max. 4.2 Fourteen, 1.3-dia. holes<br>**----- End of picture text -----**<br>
**Note:** Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.
General-purpose Relay **MY New model**
12
## **Hold-down Clips**
**==> picture [109 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
PYC-A1<br>(2 pcs per set)<br>36.3<br>4.5<br>4.5 1.2<br>**----- End of picture text -----**<br>
**==> picture [90 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
PYC-E1<br>(2 pcs per set)<br>36.3<br>5.75<br>4.25<br>4.5 [±][0.1]<br>**----- End of picture text -----**<br>
**==> picture [109 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
PYC-P<br>5<br>29 max.<br>3.3<br>38.5<br>1]<br>**----- End of picture text -----**<br>
## **PYC-P2**
**==> picture [62 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
10<br>28<br>7<br>**----- End of picture text -----**<br>
## **- Mounting Plates for Back connecting Sockets**
**==> picture [24 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
PYP-1<br>**----- End of picture text -----**<br>
**==> picture [108 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
Two, 3.4-dia. holes 51<br>my 42-£0.1 49<br><ay,<br>t=1.6<br>**----- End of picture text -----**<br>
## **PYP-36**
72 elliptical holes
## **PYP-18**
72 elliptical holes
General-purpose Relay **MY New model**
13
## **Tracks and Accessories**
## **Supporting Tracks**
## **PFP-50N/PFP-100N**
**==> picture [471 x 336] intentionally omitted <==**
**----- Start of picture text -----**<br>
7.3±0.15<br>4.5<br>35±0.3 27±0.15<br>1<br>15 25 25 25 25 15 (5)<br>10 10<br>1000 (500) *<br>Note: The figure in the parentheses is for PFP-50N.<br>PFP-100N2<br>16<br>4.5<br>35±0.3 27 24 29.2<br>aE SS == Se a<br>15 25 10 25 1000 25 10 25 15 1 1.5<br>eZ s e t<br>End Plate<br>PFP-M<br>10<br>M4 x 8 pan head screw 6.2 1.8<br>la 1<br>50 35.5 35.3<br>1.8<br>M! :<br>11.5<br>av M4 spring washer10 - /Fi 1.34.8<br>**----- End of picture text -----**<br>
## **Spacer**
**==> picture [28 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
PFP-S<br>**----- End of picture text -----**<br>
**==> picture [98 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
16<br>5 12<br>34.8<br>44.3<br>16.5 |<br>**----- End of picture text -----**<br>
General-purpose Relay **MY New model**
14
## **Precautions**
Refer to _General Precautions_ on page 11 of the _General-purpose Relays and Power Relays Group_ Catalog (X034).
## ■ **Connections**
Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays.
## ■ **Mounting**
- Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement.
General-purpose Relay **MY New model**
15
## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.**
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J111-E1-03 **In the interest of product improvement, specifications are subject to change without notice. OMRON RELAY & DEVICES Corporation General Purpose Relay Division Marketing & Product Engineering Department** 1110 Sugi, Yamaga-City, Kumamoto, 861-0596 Japan Tel: (81)968-44-4160/Fax: (81)968-44-4107 Printed in Japan
16
**Read and Understand This Catalog**
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
## **Warranty and Limitations of Liability**
## **WARRANTY**
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
## **LIMITATIONS OF LIABILITY**
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
## **Application Considerations**
## **SUITABILITY FOR USE**
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
## **Disclaimers**
## **CHANGE IN SPECIFICATIONS**
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product.
## **DIMENSIONS AND WEIGHTS**
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
**ERRORS AND OMISSIONS** The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
## **PERFORMANCE DATA**
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
## **PROGRAMMABLE PRODUCTS**
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
## **COPYRIGHT AND COPY PERMISSION**
This catalog shall not be copied for sales or promotions without permission.
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.
Cat. No. J111-E1-03
## OMRON Corporation
In the interest of product improvement, specifications are subject to change without notice.
2007.3
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Updated at June 7, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →