MLH300PSB06A
Pressure Sensor, 300 psi, Ratiometric, Sealed Gauge, 5 VDC, 1/8
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: 1/8" - 27 NPT
- Product Range: MLH Series
- Sensor Output: Ratiometric
- Supply Current: 4mA
- Voltage Rating: 5VDC
- Operating Pressure Max: 300psi
- Pressure Measurement Type: Sealed Gauge
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 127.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
_32328895 Issue B_ Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi ## Datasheet ## FEATURES - Pressure range of 6 bar to 550 bar | 50 psi to 8,000 psi - ±0.25% full scale accuracy Best Fit Straight Line (BFSL) - Total Error Band (TEB) as low as 2 %FSS - Compensated and operating temperature range of -40°C to 125°C [-40°F to 257°F] (see Table 4) - Less than 2 ms response time - Fully temperature compensated, calibrated and amplified - Rated IP65 or better for protection from most harsh environments - RoHS, CE, UL Component Recognition for USA and Canada: File No. E258956 ## DESCRIPTION The MLH Series Heavy Duty Pressure Transducers combine Application Specific Integrated Circuit (ASIC) technology with a media-isolated, metal diaphragm design. This digitally compensated transducer offers value and performance, making it a suitable pressure sensing solution for demanding applications. Industry standard electrical connectors and pressure ports are offered for enhanced reliability and user flexibility. The MLH Series has six standard output options: - Ratiometric: 0.5 Vdc to 4.5 Vdc from 5 Vdc excitation - Current: 4 mA to 20 mA - Regulated: 1 Vdc to 6 Vdc - Regulated: 0.25 Vdc to 10.25 Vdc - Regulated: 0.5 Vdc to 4.5 Vdc - Regulated: 1 Vdc to 5 Vdc ## VALUE TO CUSTOMERS - Total Error Band (TEB) as low as 2 %FSS from -40°C to 125°C: Provides indication of the transducer’s true measurement performance over a specified temperature range; small error promotes system uptime and efficiency. (See Figure 1.) ## POTENTIAL APPLICATIONS - Industrial: Compressors, cylinder tank pressure, HVAC, hydraulics, oil and gas, refrigeration, water distribution - Transportation: Multiple applications including braking and alternative fuels - Medical: Anesthesia delivery machines, blood analyzers, chemistry analyzers, gas chromatography, oxygen concentrators, and ventilators ## PORTFOLIO The MLH Series joins the PX3 Series, PX2 Series, SPT Series heavy duty pressure transducers and the 13 mm Series and 19 mm Series heavy duty pressure transducers. ## Figure 1. Total Error Band (TEB) Definition ## **Sources of Error** |**Sources of Error**|| |---|---| |Offset|**Total**<br>**Error**<br>**Band**<br>**Accuracy**<br>**BFSL**| |Full Scale Span|| |Pressure Non-Linearity|| |Pressure Hysteresis|| |Pressure Non-Repeatability|| |Thermal Effect on Offset|| |Thermal Effect on Span|| |Thermal Hysteresis|| - All metal wetted parts allow for potential use in a wide variety of fluid applications. - No internal elastomeric seals eliminate O-ring compatibility issues. - Amplified outputs reduce the need to purchase external amplifiers. - Input reverse voltage protection guards against mis-wiring. - Less than 2 ms response time provides more accurate, high speed measurement. **Sensing and Internet of Things** ## Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Table 1. Pressure Range Specifications[1] (At 25°C [77°F] and at rated excitation unless otherwise specified.) ||||||| |---|---|---|---|---|---| |bar|||psi||| |Operating<br>Pressure|Proof<br>Pressure|Burst<br>Pressure|Operating<br>Pressure|Proof<br>Pressure|Burst<br>Pressure2| |6|18|60|50|150|500| |10|30|100|100|300|1000| |16|48|160|150|450|1500| |25|75|250|200|600|2000| |40|80|400|250|750|2500| |60|120|600|300|900|3000| |100|200|1000|500|1500|5000| |160|320|1600|1000|2000|10000| |250|500|2068|2000|4000|20000| |350|700|2068|3000|6000|30000| |500|750|2068|5000|7500|30000| |550|825|2068|8000|12000|30000| 1 Comparable metric units follow same proof and burst specifications. 2 Bonded washer seal used on G 1/8 (DIN 3852-2) port is limited to 25000 psi burst. Table 2. Electrical Specifications (At 25°C [77°F] unless otherwise noted.) **==> picture [542 x 253] intentionally omitted <==** **----- Start of picture text -----**<br> Output Signal<br>Characteristic Ratiometric Current Regulated Regulated Regulated Regulated<br>A B C D E G<br>Zero output 0.5 Vdc 4 mA 1 Vdc 0.25 Vdc 0.5 Vdc 1 Vdc<br>4 Vdc<br>Full scale 4 Vdc 16 mA 5 Vdc 10 Vdc 4 Vdc<br>(0.5 Vdc to 4.5<br>span (FSS) (0.5 Vdc to 4.5 Vdc) (4 mA to 20 mA) (1 Vdc to 6 Vdc) (0.25 Vdc to 10.25 Vdc) (1 Vdc to 5 Vdc)<br>Vdc)<br>5 Vdc 9.5 Vdc to 8 Vdc to 14 Vdc to 7 Vdc to 8 Vdc to<br>Excitation<br>(6 Vdc max.) [1] 30 Vdc [2] 30 Vdc [2] 30 Vdc [2] 30 Vdc [2] 30 Vdc [2]<br>Supply 4 mA typ., N/A 5 mA typ., 5 mA typ., 5 mA typ., 5 mA typ.,<br>current 8 mA max. 17 mA max. 17 mA max. 17 mA max. 17 mA max.<br>Source<br>1 mA N/A 1 mA 1 mA 1 mA 1 mA<br>(nominal)<br>Sink 1 mA A1 mA 1 mA 1 mA 1 mA<br>N/A<br>(nominal at zero output at zero output at zero output at zero output at zero output<br>Supply 90 dB 90 dB 90 dB 90 dB 90 dB 90 dB<br>rejection ratio<br>Output 25 Ohm max. N/A 25 Ohm max. 25 Ohm max. 25 Ohm max. 25 Ohm max.<br>impedance<br>**----- End of picture text -----**<br> 1 Maintains ratiometricity at 5 ±0.25 Vdc excitation. Product can tolerate 6 Vdc excitation without damage. 2 See Figures 2 and 3 for more information regarding maximum excitation voltage vs. operating temperature. Table 3. Pressure Reference Types **==> picture [542 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> Pressure Reference Description<br>Output is proportional to the difference between applied pressure and a built-in fixed reference to<br>Sealed gage [1]<br>1 atmA, where the minimum operating pressure is set to 14.7 psiA (1 atmA).<br>Transducer measures pressure relative to ambient pressure. Output is proportional to the difference<br>Vented gage (relative) [2] between applied pressure and atmospheric (ambient) pressure, where the minimum operating<br>pressure is set to atmospheric pressure.<br>**----- End of picture text -----**<br> 2 Sensing and Internet of Things ## Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Table 4. Environmental and Mechanical Specifications (At 25°C [77°F] unless otherwise noted.) **==> picture [542 x 226] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Material in contact with media:<br> port stainless steel 304L<br> diaphragm Haynes 214 alloy<br>Housing material black plastic – Amodel AS-4133 HS – PPA<br>Weight (typical for Metri-Pack 150 and 1/8 NPT<br>57.0 g [2.0 oz]<br>pressure port types)<br>Shock 100 g peak [11 ms]<br>MIL-STD-810C, Figure 514.2-5, Curve AK, Table 514.2-V,<br>Vibration<br>Random Vibration Test (overall g rms = 20.7 min.)<br>Compensated and operating temperature range:<br> 0.5 Vdc to 4.5 Vdc ratiometric output -40°C to 125°C [-40°F to 257°F]<br> all regulated and 4 mA to 20 mA outputs -40°C to 125°C [-40°F to 257°F] (See Figures 2 and 3 for operating area details.)<br>Storage temperature range -40°C to 125°C [-40°F to 257°F]<br>Approvals RoHS, CE, UL Component Recognition for USA and Canada: File No. E258956<br>**----- End of picture text -----**<br> Table 5. Performance Specifications (At 25°C [77°F] unless otherwise noted.) **==> picture [543 x 247] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Response time <2 ms<br>Accuracy [1] :<br> >100 psi ±0.25 %FSS<br> <100 psi ±0.50 %FSS<br>Total Error Band [2] :<br> Vented gage (relative):<br> <300 psig ±3 %FSS<br> >300 psig ±2 %FSS<br> Sealed gage:<br> without L, M, P electrical connector types:<br> 100 psis to 299 psis (-40°C to 85°C [-40°F to 185°F]) ±3 %FSS<br> 100 psis to 299 psis (>85°C to 125°C [>185°F to 257°F]) ±10 %FSS<br> >300 psis (-40°C to 125°C [-40°F to 257°F]) ±2 %FSS<br> with L, M, P electrical connector types:<br> 100 psis to 299 psis (-40°C to 65°C [-40°F to 149°F]) ±10 %FSS<br> 100 psis to 299 psis (>65°C to 125°C [>149°F to 257°F]) ±15 %FSS<br> >300 psis (-40°C to 65°C [-40°F to 149°F]) ±5 %FSS<br> >300 psis (>65°C to 125°C [>149°F to 257°F]) ±15 %FSS<br>**----- End of picture text -----**<br> 1Includes pressure non-linearity (BFSL), pressure hysteresis and pressure non-repeatability. Thermal errors are not included. (See Figure 1.) 2 Includes offset error, full scale span error, pressure non-linearity (BFSL), pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. (See Figure 1.) > Sensing and Internet of Things 3 Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 2. Regulated Output Operating and Temperature Compensation **==> picture [276 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> 125<br>124<br>123<br>122<br>121 Operating and temperature<br>120 compensated area<br>119 for regulated output<br>118<br>117<br>116<br>6 8 10 12 14 16 18 20 22 24 26 28 30<br>Supply Voltage (Vdc)<br>Operating Temperature (°C)<br>**----- End of picture text -----**<br> Note: The dot indicates the maximum operating temperature of 125°C [257°F] with a 24 V supply. ## Figure 3. Current Output Operating and Temperature Compensation **==> picture [273 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> 125<br>120 10 Ohmload 250 Ohmload<br>115<br>110<br>105<br>100<br>95<br>90<br>85 Operating and temperature<br>80<br>75 compensated area<br>70 for current output<br>65<br>60<br>6 8 10 12 14 16 18 20 22 24 26 28 30<br>Supply Voltage (Vdc)<br>Operating Temperature (°C)<br>**----- End of picture text -----**<br> Note: The operating area is extended with a 250 Ohm resistor. Higher loads extend the operating area. The dot indicates the maximum operating temperature when using a 24 V supply and a 250 Ohm resistor. ## CAUTION ## PRODUCT DAMAGE DUE TO MECHANICAL ISSUES - Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.) - When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application. - Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers. - Always hand-start transducers into the hole to prevent cross threading and damage. - Ensure that torque is not applied to the electrical connector. - Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits. Failure to comply with these instructions may result in product damage. ## CAUTION ## PRODUCT DAMAGE DUE TO PARTICULATES - Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All MLH Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect transducer output. - It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less likely to enter and settle within the pressure transducer if it is in this position. - Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output; rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue. - Failure to comply with these instructions may result in product damage. 4 Sensing and Internet of Things ## Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi ## Figure 4. Nomenclature and Order GuideE For example, MLH150PSB01B defines an MLH Series Heavy Duty Pressure Transducer, 150 psi pressure range, sealed gage pressure reference, Metri-Pack 150 electrical connector type, 1/4-18 NPT pressure port type, 4 mA to 20 mA output. **==> picture [524 x 538] intentionally omitted <==** **----- Start of picture text -----**<br> MLH 150 P S B 01 B<br>Series Output Transfer Function<br>Heavy A Ratiometric: 0.5 Vdc to 4.5 Vdc<br>MLH DutyPressure from 5 Vdc excitation<br>Transducer [1] B Current: 4 mA to 20 mA<br>C Regulated: 1 Vdc to 6 Vdc<br>Pressure Range D Regulated: 0.25 Vdc to 10.25 Vdc<br> bar psi E Regulated: 0.5 Vdc to 4.5 Vdc<br>006 6 050 50 Electrical Connector Type G Regulated: 1 Vdc to 5 Vdc<br>010 10 100 100 Metri-Pack 150 [3] Cable harness,<br>1 meter cable<br>016 16 150 150<br>length [3] Pressure Port Type<br>025 25 200 200 1/4-18 NPT M10x1 with O-ring seal<br>040 40 250 250 (ANSI B1.20.1) (ISO 6149-2) [5]<br>B L 01 54<br>060 60 300 300<br>= 7 Go<br>100 100 500 500<br>160 160 01K 1000 1/8-27 NPT M12x1.5 with O-ring seal<br>(ANSI B1.20.1) (ISO 6149-2) [5]<br>— 250 250 02K 2000 Hirschmann Cable harness, 06 55<br>350 350 03K 3000 3 meter cable<br>= length [33]<br>500 500 05K 5000 7/16-20 UNF M14x1.5 with O-ring seal<br>550 550 08K 8000 C M 09 1/4 in 45ºFlare Female 56 (ISO 6149-2) [5]<br>—= — — la<br>Schrader with<br>im a =<br>depressor<br>Unit 1 =<br>1/2-14 NPT M16x1.5 with O-ring seal<br>B bar M12x1 11 (ANSI B1.20.1) 57 (ISO 6149-2) [5]<br>(Brad Harrison micro) Flying leads<br>P psi<br>aa =<br>R 1/4-19 BSPT M18x1.5 with O-ring seal<br>Pressure Reference (ISO 7-1) (ISO 6149-2) [5]<br>G Vented gage (relative) D @ == 13 58<br>S Sealed gage [2] P<br>R 1/8-28 BSPT = M20x1.5 with O-ring seal hUm<br>(ISO 7-1) (ISO 6149-2) [5]<br>19 59<br>DIN 43650-C, 8 mm male<br>sh =<br>3/8-24 UNF with O-ring seal G1/8-28 BSPP<br>Metri-Pack 150 mating connector [3] (SAE J1926-2) [5] with bonded washer<br>G 50 60 (DIN 3852-2) [5, ][6]<br>Deutsch DTM04-3P a<br>(integral)<br>7/16-20 UNF with O-ring seal G1/4-19 BSPP<br>(SAE J1926-2) [5] with bonded washer<br>51 61 (DIN 3852-2) [5, ][6]<br>AMP Superseal 1.5 [4]<br>1/2-20 UNF with O-ring seal G1/8-28 BSPP<br>T (SAE J1926-2) [5] with elastomeric seal<br>52 62 (ISO 1179-2) [5]<br>H<br>9/16-18 UNF with O-ring seal G1/4-19 BSPP<br> (SAE J1926-2) [5] with elastomeric seal<br>53 63 (ISO 1179-2) [5]<br>—<br>**----- End of picture text -----**<br> - 1 Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell. - 2 Sealed gage option is only available in pressure ranges at or above 8 bar | 100 psi. - 3 Metri-Pack 150 mating connectors with shielded cable and 22 AWG wire are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] cable length and part no. 3685302 for 3 m [9.8 ft] cable length. - 4 Available with Output Transfer Function A only. - 5 Seal accessory is included with the sensor. Seal accessory materials and specifications are: O-ring (nitrile, durometer 90, temperature range -30°C to 125°C), bonded washer (steel outer ring with nitrile inner ring, temperature range -30°C to 125°C), elastomeric seal (nitrile, temperature range -30°C to 125°C). - 6 When using the bonded washer accessory supplied by Honeywell, the customer’s female port connection design should follow DIN 3852-1: 2000-11 size large. If compliance to DIN 3852-1:2014-05 is required, contact Honeywell for alternate options. 5 Sensing and Internet of Things ## Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 5. Electrical Connector Type Mounting Dimensions (For reference only. mm/[in].) **==> picture [542 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> “H” + “P” = total nominal product length General product marking<br>Catalog listing<br> 27,0 Hex flat to flat<br> [1.06] Date code<br>“H” “P”<br>B C D G<br>Metri-Pack 150 Hirschmann M12x1 (Brad Harrison micro) DIN 43650-C, 8 mm male<br>Connector: Delphi 12078088 Connector: Hirschmann G Connector: DS/EN 61076-2- Connector: DIN 43650C, 8 mm<br>Mating connector: Delphi series, 4-pole (small cubic 101 (IEC 61076-2-101) Mating connector: DIN<br>12110192 connector) Mating connector: 4 POS 43650C, 8 mm<br>IP rating [1] : IP65 (all versions) Mating connector: Hirschman Type D IP rating [1] : IP65 (all versions)<br>G4WF or equivalent IP rating [1] : IP65, IP67 (sealed<br>IP rating [1] : IP65 (all versions) gage versions), IP65 (vented<br>gage versions)<br>Voltage Current Voltage Current Voltage Current Voltage Current<br>Pin Output Output Pin Output Output Pin Output Output Pin Output Output<br>(3-wire) (2-wire) (3-wire) (2-wire) (3-wire) (2-wire) (3-wire) (2-wire)<br>no no<br>A +excitation +excitation 1 1 +excitation +excitation 1 +excitation +excitation<br>connection connection<br>no no -excitation -excitation<br>B common 2 output 2 common 2 common<br>connection connection (return) (return)<br>-excitation -excitation no no no<br>C output 3 common 3 output 3<br>(return) (return) connection connenction connection<br>no no no<br>4 +excitation +excitation 4 4 output<br>connection connection connection<br>Pin C Pin 3<br>Pin 1 Pin 4 Pin 4 Pin 3<br>Pin A Pin B Pin 2<br>Pin 2 Pin 1<br>Pin 1<br>Pin 3<br>Pin 2<br>No connection Pin 4<br>ø16,51<br> [0.46] 17,0<br>[0.67]<br>ø16,0 ø10,0<br> [0.63] [0.39]<br>“H” = 41,7 Hole<br> [1.64] Hole(Vented [1.28]“H” = 32,6 Hole(Vented [1.32]“H” = 33,5 Hole(Vented [1.19]“H” = 30,1 (Ventedgage versions<br>gage versionsonly) gage versionsonly) gage versionsonly) only)<br>**----- End of picture text -----**<br> 6 Sensing and Internet of Things Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 5. Electrical Connector Type Mounting Dimensions (continued) **==> picture [541 x 596] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>T<br>H Cable Harness, 1 Meter P<br>Deutsch DTM04-3P<br>AMP Superseal 1.5 M Flying Leads<br>(integral)<br>Cable Harness, 3 Meter<br>Connector: Amp 282087 Connector: 24 AWG with TPE Connector: 6 in flying leads Connector: DTM04-3P<br>Mating connector: Amp jacket with 20 AWG wire and PE Mating connector: DTM06-<br>282087 Mating connector: Flying insulation 3S with wedgelock WM-3S<br>IP rating [1] : IP65 (all versions) leads IP rating [1] : IP65, IP67, IP69K IP rating [1] : IP65, IP67, IP69K<br>IP rating [1] : IP65, IP67, IP69K (sealed gage versions), IP65 (sealed gage versions), IP65<br>(sealed gage versions), IP65 (vented gage versions) (vented gage versions)<br>(vented gage versions)<br>Voltage Wire Voltage Current Wire Voltage Current Voltage Current<br>Pin Output Color Output Output Color Output Output Pin Output Output<br>(3-wire) (3-wire) (2-wire) (3-wire) (2-wire) (3-wire) (2-wire)<br>1 common red +excitation +excitation red +excitation +excitation 1 +excitation +excitation<br>-excitation -excitation -excitation<br>2 output white output white common 2 common<br>(return) (return) (return)<br>no no<br>connection connection no<br>3 +excitation black common (black wire black output (black wire 3 output connection<br>removed) removed)<br>White<br>White<br>Black Red<br>(Used for voltage Pin 2 Pin 1<br>Pin 3 ouptut only)<br>Pin 2<br>Red<br>Black<br>Pin 1 (Used for voltageouptut only) Pin 3<br> 13,4<br> [0.53]<br> [0.54]13,8 ø10,8 ø10,8<br> [0.43] [0.43]<br> [1.61]“H” = 41,0 Hole(Ventedgage versionsonly) [1.39]“H” = 35,3 Hole(Ventedgage versionsonly) [1.39]“H” = 35,3 Hole(Ventedgage versions [1.68]“H” = 42,6 Hole(Ventedgage versionsonly)<br>only)<br>**----- End of picture text -----**<br> - 1 IP rating is determined by the electrical connector type chosen. 2 Three-wire cable is required for ratiometric and regulated voltage outputs; two wire cable is required for current output. 7 Sensing and Internet of Things ## Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 6. Pressure Port Type Mounting Dimensions (For reference only: mm/[in].)[1] **==> picture [542 x 666] intentionally omitted <==** **----- Start of picture text -----**<br> “H” + “P” = total nominal product length General product marking<br>Catalog listing<br> 27,0 Hex flat to flat<br> [1.06] Date code<br>“H” “P”<br>09<br>01 06<br>7/16-20 UNF 1/4 in 45º<br>1/4-18 NPT 1/8-27 NPT<br>Flare Female Schrader with depressor<br>Seal: Pipe thread Seal: Pipe thread Seal: 45º cone<br>Mating geometry: ANSI B1.20.1-2013 Mating geometry: ANSI B1.20.1-2013 Mating geometry: SAE J512<br>Installation torque: 2 to 3 turns from Installation torque: 2 to 3 turns from Installation torque: 20 Nm [14.8 ft-lb]<br>finger tight finger tight<br> [0.79]“P” = 20,1 [0.60]15,2 [0.59]“P” = 15,0 [0.40]10,2 [0.69]“P” = 17,5 [0.50]12,7<br>11 13 19<br>1/2-14 NPT R1/4-19 (BSPT) R1/8-28 (BSPT)<br>Seal: Pipe thread Seal: Pipe thread Seal: Pipe thread<br>Mating geometry: ANSI B1.20.1-2013 Mating geometry: ISO 7-1 Mating geometry: ISO 7-1<br>Installation Torque: 2 to 3 turns from Installation Torque: 2 to 3 turns from Installation Torque: 2 to 3 turns from<br>finger tight finger tight finger tight<br> [0.98]“P” = 24,9 [0.79]20,1 P” = 19,6 [0.77] [0.58]14,7 [0.59]“P” = 15,0 [0.40]10,2<br>50 51 52<br>3/8-24 UNF (SAE J1926-2) 7/16-20 UNF (SAE J1926-2) 1/2-20 UNF (SAE J1926-2)<br>Seal [1] : O-ring Seal [1] : O-ring Seal [1] : O-ring<br>Mating geometry: SAE J1926-1 Mating geometry: SAE J1926-1 Mating geometry: SAE J1926-1<br>Installation torque: 10 N m [7.4 ft-lb] Installation torque: 20 N m [14.8 ft-lb] Installation torque: 40 N m [29.5 ft-lb]<br>“P” = 18,3 “P” = 19,8 “P” = 19,8<br> [0.72] 13,5 [0.78] 15,0 [0.78] 15,0<br>[0.53] [0.59] [0.59]<br>53 54 55<br>9/16-18 UNF (SAE J1926-2) M10x1.0 (ISO 6149-2) M12x1.5 (ISO 6149-2)<br>Seal [1] : O-ring Seal [1] : O-ring Seal [1] : O-ring<br>Mating geometry: SAE J1926-1 Mating geometry: ISO 6149-2 Mating geometry: ISO 6149-2<br>Installation torque: 45 N m [33.2 ft-lb] Installation torque: 20 N m [14.8 ft-lb] Installation torque: 45 N m [33.2 ft-lb]<br> [0.82]“P” = 20,8 [0.63]16,0 [0.63]“P” = 15,9 [0.44] 11,1 [0.72]“P” = 18,3 [0.53] 13,5<br>**----- End of picture text -----**<br> 8 Sensing and Internet of Things ## Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 6. Pressure Port Type Mounting Dimensions (continued) **==> picture [542 x 590] intentionally omitted <==** **----- Start of picture text -----**<br> 56 57 58<br>M14x1.5 (ISO 6149-2) M16x1.5 (ISO 6149-2) M18x1.5 (ISO 6149-2)<br>Seal [1] : O-ring Seal [1] : O-ring Seal [1] : O-ring<br>Mating geometry: ISO 6149-1 Mating geometry: ISO 6149-1 Mating geometry: ISO 6149-1<br>Installation torque: 45 N m [33.2 ft-lb] Installation torque: 55 N m [40.6 ft-lb] Installation torque: 70 N m [51.6 ft-lb]<br>“P” = 18,3 “P” = 21,3<br> [0.72] [0.53]13,5 “P” = 19,8 [0.78] [0.59]15,0 [0.84] [0.65]16,5<br>59 60 61<br>M20x1.5 (ISO 6149-2) G1/8-28 (BSPP) DIN 3852-2 G1/4-19 (BSPP) DIN 3852-2<br>Seal [1] : O-ring Seal [1] : Bonded washer Seal [1] : Bonded washer<br>Mating geometry: ISO 6149-1 Mating geometry with bonded washer: Mating geometry with bonded washer:<br>Installation torque: 80 N m [59.0 ft-lb] DIN3852-1; 2000-11, large DIN 3852-1:2000-11, large<br>Installation torque: 20 N m [14.8 ft-lb] Installation torque: 50 N m [36.9 ft-lb]<br>“P” = 19,0<br> [0.75] 14,1<br> [0.56]<br>“P” = 14,6<br> 9,7<br> [0.57]<br> [0.38]<br>2,0<br>“P” = 21,3 [0.08] Bonded washer<br> [0.84] 16,5 2,0 Bonded washer<br> [0.65 [0.08]<br>Bonded ø13,7 ø20,6<br>Bonded ø10,4 washer [0.54] [0.81]<br>washer [0.41] [0.63] [ø][15,9]<br>62 63<br>G1/8-28 (BSPP) ISO 1179-2 G1/4-19 (BSPP) ISO 1179-2<br>Seal [1] : Elastomeric Seal [1] : Elastomeric<br>Mating geometry: ISO 1179-1 Mating geometry: ISO 1179-1<br>Installation torque: 20 N m [14.8 ft-lb] Installation torque: 50 N m [36.9 ft-lb]<br>“P” = 18,8<br>“P” =14,3 [0.74] [0.55]14,0<br> [0.56] 9,5<br>[0.37]<br>0,8 Proper assembly of<br>[0.02]0,5 Proper assembly ofseal to stud end [0.03] seal to stud end<br>Elastomeric ø8,4 120° ø11,9 Elastomeric ø11,6 120° ø16,5<br> seal [0.33] [0.47] seal [0.46] [0.65]<br>1,0<br>[0.04]<br>1,5<br>[0.06]<br>**----- End of picture text -----**<br> 1 Seal accessory included with transducer. Seal accessory material and specifications: O-ring (nitrile, durometer 90, temperature range -30°C to 125°C), bonded washer (steel outer ring with nitrile inner ring, temperature range -30°C to 125°C), elastomeric seal (nitrile, temperature range -30°C to 125°C). > Sensing and Internet of Things 9 ## ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: - Product line guide - Product range guide - Product installation instructions - Product CAD models ## WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. ## WARNING ## MISUSE OF DOCUMENTATION - The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. ## Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. ## For more information Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit sensing.honeywell.com or call: Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 USA/Canada +1-800-537-6945 While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. ## Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywell.com 32328895-B-EN | B | 03/18 © 2018 Honeywell International Inc. All rights reserved.
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →