- Manufacturer: EOS POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: MFLS250 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 18A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 350W @ 375LFM
- Power Rating (Convection Cooling): 250W
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 117.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Medical Grade Silent 250 Watt AC-DC Power Supplies** Oy Ee ## **250 Watt** ## l 4.5 x 2.5 X 1.5 - l Mounting as Per 4 X 2 Footprint/ 3 X5 Footprint - l 250 Watts Convection Cooled & 350 Watts Forced Cooled - l Efficiency up to 94% - l -40 to 70 °C operating temperature - l High power density : 20.74W/inch[3] - l Meets EN60601-1-2, 4[th] Edition - l 12 V Fan O/P / Thermal Shut-Down feature / Dual fusing - l Current Sharing (Optional with ADD-ON CARD) - l 5 V STBY/ PGPF Signal / Remote ON-OFF Feature (Optional ) - l 2.56m Hours, Telcordia -SR332-issue 3 MTBF - l No Load Power < 1W - l Suitable for BF applications - l Available with metal enclosures/accessories **Dimension** The New MFLS250 series is true fanless power up to 250W. this is a highly efficient power supply that can deliver up to 350W with air. The power supply is packed in 4.5’ x 2.5’ size having the ~~**FLS :** 4.5 x 2.5 x 1.5 Inches~~ option of industry-standard “2 x 4” or “3 x 5” like a mounting option. Also available in various ~~Form factor~~ type of casing option. ## ~~**250 Watts**~~ |~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~|~~**250 Watts**~~| |---|---|---|---|---|---|---|---|---| |~~**250 Watts**~~||||||||| |||||||||| ||**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**<br>**(Convection) (375 LFM)**|**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**<br>**(Convection) (375 LFM)**|**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**<br>**(Convection) (375 LFM)**|**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**<br>**(Convection) (375 LFM)**|**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**<br>**(Convection) (375 LFM)**|**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Max. Load Min. Load Ripple**1|| ||**(Convection) (375 LFM)**|**(Convection) (375 LFM)**|**(Convection) (375 LFM)**|**(Convection) (375 LFM)**|**(Convection) (375 LFM)**|||| |Pe|MFLS250-1X12<br>~~ee~~<br>~~es~~|with Screw Terminal<br>~~eG~~|12V<br>~~eG~~|16.60A<br>~~eG~~<br>~~QO~~|25.00A<br>~~eG~~<br>~~QO~~|0.0A<br>~~eG~~<br>~~QO~~|2%<br>~~eG~~|| ||MFLS250-1X12<br>~~ee~~<br>~~a ~~<br>~~es~~|with JST Connector<br>~~eG~~<br> ~~GG~~|12V<br>~~eG~~<br>~~GG~~|16.60A<br>~~eG~~<br>~~GG~~<br>~~QO~~|18.00A<br>~~eG~~<br>~~GG~~<br>~~QO~~|0.0A<br>~~eG~~<br>~~GG~~<br>~~QO~~|2%<br>~~eG~~<br>~~GG~~|| ||MFLS250-1X15<br>~~es~~<br>~~Rs~~|with Screw Terminal|15V|13.30A<br>~~QO~~|20.00A<br>~~QO~~|0.0A<br>~~QO~~|2%|| ||MFLS250-1X15<br>~~es~~<br>~~Rs~~<br>Pe|with JST Connector<br>|15V<br>|13.30A<br>~~QO~~<br>|18.00A<br>~~QO~~<br>|0.0A<br>~~QO~~<br>|2%<br>|| ||MFLS250-1X24<br>MFLS250-1X24<br>~~Rs~~<br>Pe~~es~~|with Screw Terminal<br>with JST Connector<br>~~GG~~|24V<br>24V<br>~~GG~~|10.41A<br>10.41A<br>~~GG~~|14.50A<br>14.50A<br>~~GG~~|0.0A<br>0.0A<br>~~GG~~|1%<br>1%<br>~~GG~~|| ||MFLS250-1X30<br>~~es~~<br>~~Rs~~|with Screw Terminal<br>~~GG~~<br>|30V<br>~~GG~~<br>~~GG~~<br>|8.30A<br>~~GG~~<br>~~GG~~<br>|11.60A<br>~~GG~~<br>~~OO~~<br>|0.0A<br>~~GG~~<br>|1%<br>~~GG~~<br>|| ||MFLS250-1X30<br>MFLS250-1X48<br>~~es~~<br>~~eG~~<br>~~Rs~~<br>~~es~~|with JST Connector<br>with Screw Terminal<br>~~GG~~<br>~~eG~~<br>~~GG~~|30V<br>48V<br>~~GG~~<br>~~eG~~<br>~~GG~~<br>~~GG~~|8.30A<br>5.20A<br>~~GG~~<br>~~eG~~<br>~~GG~~<br>~~GG~~<br>~~OO~~|11.60A<br>7.20A<br>~~GG~~<br>~~eG~~<br>~~OO~~<br>~~GG~~<br>~~OO~~|0.0A<br>0.0A<br>~~GG~~<br>~~eG~~<br>~~GG~~<br>~~OO~~|1%<br>1%<br>~~GG~~<br>~~eG~~<br>~~GG~~|| ||MFLS250-1X48<br>~~Rs~~<br>~~es~~<br>~~es~~|with JST Connector<br>|48V<br>~~GG~~<br>|5.20A<br>~~GG~~<br><br>~~OO~~|7.20A<br>~~OO~~<br><br>~~OO~~<br>~~QO~~|0.0A<br><br>~~OO~~|1%<br>|| ||MFLS250-1X58<br>~~es~~<br>~~QQ~~<br>~~es~~|with Screw Terminal<br>~~QQ~~|58V<br>~~QQ~~|4.30A<br>~~OO~~<br>~~QQ~~|6.0A<br>~~OO~~<br>~~QQ~~<br>~~QO~~|0.0A<br>~~OO~~<br>~~QQ~~|1%<br>~~QQ~~|| ||MFLS250-1X58<br>~~es~~|with JST Connector|58V|4.30A|6.0A<br>~~QO~~|0.0A|1%|| |~~a~~|For Screw Terminal version replace “X” above with “0”, example MFLS250-1024<br>For Header version replace “X” above with “3”, example MFLS250-1324<br>Add Suffix “B“ for 3 X 5 Mounting option, example MFLS250-1024-B<br>For Current Sharing (ADD-ON CARD) Option contact sales person.<br>For 5V STBY / Remote ON-OFF / PGPF used model number MFLS250-2XXX (Contact Sales for more details)<br>~~QO~~<br>~~es~~<br>~~a~~|||||||| |MFLS250-CK Metal Cover Kit Accessory Available.<br>~~a,~~||||||||| MFLS250-CK Metal Cover Kit Accessory Available. ~~a,~~ **www.eospower.com** ~~4EM-21-295 1 39-DE60-42759-002 / A~~ **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Pin Connection** |**Pin Connection**||| |---|---|---| |J1 (Input)|PIN 1|AC LINE| ||PIN 2|NOT FITTED| ||PIN 3|AC NEUTRAL| |J2 Option 1 & 2|PIN 1,2,3|V1 +VE| |(Output)|PIN 4,5,6|V1 -VE| |J4 (Earth)||Quick Disconnect| |(J9)|PIN 1|+VS| |Signal Connector|PIN 2|-VS| ||PIN 3|FAN -| ||PIN 4|FAN +| |J(310)|PIN 1|+5V| |(Multifunction Connector)***|PIN 2|GND| ||PIN 3|GND| ||PIN 4|REMOTE ON/OFF| ||PIN5|PGPF| ## Notes 1. ”***” mark content available only in MFLS250-2XXX series 2. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. ~~3. Specifcatons are for nominal input voltage, 25~~ ° ~~C unless otherwise stated.~~ ~~4. 250W with natural convecton cooling at 100 to 264VAC.~~ ~~5. 350W with Forced cooling at 100 to 264VAC.~~ ~~6. Combine Output Power of Main Output, Fan supply and Standby shall not exceed max power ratng.~~ 7. Output ripple can be more than 1 % of the output voltage. 8. When used in Cover Kit, de-rate output power to 70% under all operating conditions. 9. ”***” Standby output voltage 5 V/ 0.5A(convection) with tolerance including set point accuracy, line and load regulation is +/-10 %.Ripple and noise is less than 5 %. ## ~~**Input**~~ |~~**Input**~~|||| |---|---|---|---| |**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**| |Input Voltage|85<br>264|VAC|De-rate linearly from 100% at 100VAC to 80% at 85VAC| ||120<br>370|VDC|| |Input Frequency|47<br>63|Hz|| |Input Current|6.3|A|| |Inrush Current|115 VAC - 25A<br>264 VAC -75A<br>230VAC - 45A|A|| |No Load Input Power|1|W|| |Power Factor|exceeds 0.95 at Full Load||| **www.eospower.com** ~~4EM-21-295 2 39-DE60-42759-002 / A~~ **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Output** ||**Characteristic Minimum Typical Maximum Units Notes & Conditions**<br>esSd|**Characteristic Minimum Typical Maximum Units Notes & Conditions**<br>Sd|**Characteristic Minimum Typical Maximum Units Notes & Conditions**<br>rs|**Characteristic Minimum Typical Maximum Units Notes & Conditions**<br>eG|**Characteristic Minimum Typical Maximum Units Notes & Conditions**<br>eG|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**| |---|---|---|---|---|---|---|---| ||Output Power<br>esSd<br>Rs|Sd<br>es|250<br>rs<br>es|350<br>eG<br>GO|W<br>eG<br>GO||| ||Hold-up Time<br>esSd<br>Rs<br>rs|Sd<br>es<br>re|8mS<br>rs<br>es<br>rs|eG<br>GO<br>QR|eG<br>GO<br>QR|At 230 VAC|| ||Line Regulation<br>Rs <br>rs<br>rs|es<br>re<br>re|es<br>rs<br>rs|+/-0.5%<br>GO<br>QR<br>GR|GO<br>QR<br>QO||| ||Line Regulation<br>Load Regulation<br>rs<br>rs<br>Rs|re<br>re<br>es|rs<br>rs<br>es|+/-0.5%<br>QR<br>GR<br>GQ|QR<br>QO<br>GQ||| ||Load Regulation<br>Output Voltage Adjustability<br>rs<br>Rs<br>~~es~~|re<br>es<br>~~es~~|rs<br>es<br>~~rs(Qe~~|+/-3%<br>GR<br>GQ<br>~~(Qe~~|QO<br>GQ<br>~~(Qe~~|~~(Qe~~|| ||Rise Time<br>Rs <br>~~es~~<br>~~es~~|es<br>~~es~~<br>~~es~~|55<br>es<br>~~rs(Qe~~<br>~~esGQ~~|GQ<br>~~(Qe~~<br>~~GQ~~|ms<br>GQ<br>~~(Qe~~<br>~~GQ~~|~~(Qe~~<br>~~GQ~~|| |(se|Set Point Tolerance<br>~~es ~~<br>~~es~~<br>~~Rs~~|~~es~~<br>~~es~~<br>re|+/-1%<br>~~rs(Qe~~<br>~~esGQ~~<br>eG|~~(Qe~~<br>~~GQ~~<br>eG|~~(Qe~~<br>~~GQ~~<br>QO|~~(Qe~~<br>~~GQ~~|| ||Over Current Protection<br>~~es ~~<br>~~Rs~~<br>es|~~es ~~<br>re<br>rs|> 110%<br> ~~esGQ~~<br>eG<br>rs~~GG~~|~~GQ~~<br>eG<br>~~GG~~|~~GQ~~<br>QO<br>~~GG~~|~~GQ~~<br>~~GG~~|| ||Over Voltage Protection<br>~~Rs~~<br>es<br>(se|re<br>rs<br>(se|110 to 140%<br>eG<br>rs~~GG~~<br>~~Pe~~|eG<br>~~GG~~<br>~~Pe~~|QO<br>~~GG~~<br>~~Pe~~|~~GG~~<br>~~Pe~~|| |25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms<br>Transient Response<br>es<br>(se||25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms<br>rs<br>(se|25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms<br>rs~~GG~~<br>~~Pe~~||||| ## **General** |**General**|| |---|---| |**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**| |Efficiency<br>92%<br>94%|At 230 VAC| |Mean Time BetweenFailure<br>2.56m Hours|Telcordia -SR332-issue 3| |<br>Isolation: Input to Output<br>4380|Input to Output: 4380VAC (2x MOPP),| |Input to Ground<br>1690|Input to Ground: 1690VAC (1x MOPP),<br>VAC| |Output to Ground<br>1500|Output to Ground: 1500VAC (1x MOPP)| |Leakage Current<br>300 uA Typical; Touch current <100uA|300 uA Typical; Touch current <100uA| ## ~~**Effciency Vs Load**~~ ~~4EM-21-295 3 39-DE60-42759-002 / A~~ ~~**www.eospower.com**~~ **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Environmental** **==> picture [531 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Characteristic Minimum Typical Maximum Units Notes & Conditions| |Operating Temperature|-40|70|°C|-40 to 0 startup is guaranteed with spec deviation.| |70°C (Derated)| |Storage Temperature|-40|85|°C| |Relative Humidity|5|95|%| |Operating Altitude|16,000|ft|RH, non-condensing| |Short Circuit Protection|Hiccup mode| |Switching Frequency|PFC – 70 to 130 KHz ,PWM – 50-80 KHz| |Cooling|350W with 375 LFM forced air cooling at 100 to 264VAC| |250W with natural convection cooling at 100 to 264VAC| **----- End of picture text -----**<br> ## ~~**Signals & Controls**~~ **==> picture [521 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Characteristic Notes & Conditions| |***Power Good|Is a TTL signal which goes high after main output reaches 90% of its set value.| |The delay is 0.1 s to 0.5 s| |***Power Fail|The same signal goes low at least 1ms before main output falls to 90% of set value| |at AC Power off| |***Remote on/off|Shorting Pin 3 to Pin 4 enables main output while keeping the Pins open disables| |main output.| **----- End of picture text -----**<br> ## ~~**Signals & Controls Drawing**~~ ## ~~*****Power Good / Power Fail Signal**~~ ~~4EM-21-295 4 39-DE60-42759-002 / A~~ ~~**www.eospower.com**~~ ## **Silent 250 Watt** ## **Medical Grade AC-DC Power Supplies** **==> picture [173 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> Signals & Controls Drawing<br>**----- End of picture text -----**<br> **==> picture [151 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> *** Remote ON OFF<br>**----- End of picture text -----**<br> ## **Signals & Controls Drawing** ## **Voltage Sense** 4EM-21-295 5 39-DE60-42759-002 / A **www.eospower.com** ## **Medical Grade** **==> picture [523 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Silent 250 Watt| |AC-DC Power Supplies| |Mechanical Specifications| |AC Input Connector (J1)|Molex: 26-60-4030| |Mating: 09-50-3031; Pins: 08-50-0106| |DC Output Connector (J2) Option 1|Molex: 39357 Series or equivalent| |(Screw Terminal)| |DC Output Connector (J2) Option 2|JST p/n: B6P-VH(LF)(SN)| |(JST Connector)|Mating: JST p/n: VHR-6M; Pins: SVH-41T-P1.1| |Signal Connector (J9)|Molex Part No: 10-89-7041 or equivalent| |Mating part no: 1053082204 ; Pins: 1053001100| |J(310)|HEADER 5POS 2.54MM) P/N : P9102-40-12-1| |(Multifunction Connector)***|Mating part no : CONN RCPT HSNG 5POS CST-100 II P/N :1375820-5| |Pins : CONN SOCKET 22-26AWG CRIMP TIN P/N : 1375819-1| |Dimensions|4.5 x 2.5 x 1.58 inches| |(114.30 x 63.5 x 40 mm)| |Weight|400 gm approx| |=—| |EMC: Emissio|ns| |Phenomenon Standard Test Level Notes & Conditions| |Conducted|EN 55011|Level B|CISPR22-B, FCC PART15-B| |Radiated|EN 55011|Level A|Level B with external core| |(King core K5B RC 25x12x15-M or Equivalent| |in input cable)| **----- End of picture text -----**<br> ## ~~**EMC: Immunity**~~ **==> picture [437 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Phenomenon Standard Test Level Criteria Notes & Conditions| |Input CurrMedical D|e|nt Harmonicsvice EMC|EN 61000-3-2|Class A| |VL|o|w Voltage PSU EMCltage Fluctuaton and Flicker|EN 61000-3-3|compliance| |ESD ImmunityESD Immunity|EN 61000-4-2|Level 4|A| |Radiated Field ImmunityRadiated Immunity|EN 61000-4-3|Level 3|A| |Electrical Fast Transient ImmunityEFT/Burst|EN61000-4-4|Level 3|A| |SuSurgerge Immunity|EN 61000-4-5|Level 3|A| |CoConducted Immunitynducted Immunity|EN61000-4-6|Level 3|A| |Magnetc Field Immunity|EN61000-4-8|Level 4|A| |Voltage dips, interruptions|EN61000-4-11|A & B| |Standard IEC60601-1-2 : 2014 (4th Editon)| **----- End of picture text -----**<br> ## ~~**Safety Approvals**~~ **==> picture [498 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Safety Agency|Safety Standard|Notes & Conditions| |CB|IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012| |Input to Output: 4380VAC (2x MOPP),| |Nemko|EN60601-1| |Input to Ground: 1690VAC (1x MOPP),| |UL|ANSI /AAMI 60601-1| |Output to Ground: 1500VAC (1x MOPP)| |CSA|CSA C22.2 No.60601-1| |CE Mark|Complies with LVD Directve| **----- End of picture text -----**<br> ~~4EM-21-295 6 39-DE60-42759-002 / A~~ ~~**www.eospower.com**~~ ## **Silent 250 Watt** ## **Medical Grade AC-DC Power Supplies** ## **Derating Curve** De-rate linearly from 100% at 100VAC to 80% at 85VAC ## **Derating Curve** Convection load: 250W up to 40 °C. De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C Forced air cooled load: 350W up to 40 °C. De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C 4EM-21-295 7 39-DE60-42759-002 / A **www.eospower.com** ## **Silent 250 Watt** i ## **Medical Grade AC-DC Power Supplies** ## **Derating Curve** Convection load: 200W up to 40 °C. De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C Forced air cooled load: 300W up to 40 °C. De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C ## **Derating Curve** Convection load: 175W up to 40 °C. De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C 4EM-21-295 8 39-DE60-42759-002 / A **www.eospower.com** **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Mechanical Drawing** ## **Screw terminal (1XXX/ 2XXX)** 4EM-21-295 9 39-DE60-42759-002 / A **www.eospower.com** **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Mechanical Drawing** ## **Header terminal (1XXX/ 2XXX)** 4EM-21-295 10 39-DE60-42759-002 / A **www.eospower.com** **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Mechanical Drawing** ## **Screw terminal (1XXX-B/ 2XXX-B)** 4EM-21-295 11 39-DE60-42759-002 / A **www.eospower.com** **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Mechanical Drawing** ## **Header terminal (1XXX-B/ 2XXX-B)** 4EM-21-295 12 39-DE60-42759-002 / A **www.eospower.com** **Silent 250 Watt** i ## **Medical Grade AC-DC Power Supplies** ## **Mechanical Drawing** ## **MFLS250 2.5 X 4.5 with L-Bracket** 4EM-21-295 13 39-DE60-42759-002 / A **www.eospower.com** **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Mechanical Drawing** ## **MFLS250 3 X 5 with L -Bracket** **www.eospower.com** 4EM-21-295 14 39-DE60-42759-002 / A ## **Silent 250 Watt** i ## **Medical Grade AC-DC Power Supplies** ## **Mechanical Drawing** ## **MFLS250 2.5 X 4.5 with U Channel** 4EM-21-295 15 39-DE60-42759-002 / A **www.eospower.com** **Medical Grade AC-DC Power Supplies** ## **Silent 250 Watt** ## **Mechanical Drawing** ## **MFLS250 3 X 5 with U Channel** 4EM-21-295 16 39-DE60-42759-002 / A **www.eospower.com** ## **Silent 250 Watt** ## **Medical Grade AC-DC Power Supplies** ## **Mechanical Drawing** ## **MFLS250 2.5 X 4.5 with Cover kit** 4EM-21-295 17 39-DE60-42759-002 / A **www.eospower.com** **Silent 250 Watt** i **Medical Grade AC-DC Power Supplies** ## **Mechanical Drawing** ## **MFLS250 3 X 5 with Cover Kit** 4EM-21-295 18 39-DE60-42759-002 / A **www.eospower.com** **Silent 250 Watt** i ## **Medical Grade AC-DC Power Supplies** ## **Mechanical Drawing** ## **MFLS250 2.5 X 4.5 with Cover kit - Fan** 4EM-21-295 19 39-DE60-42759-002 / A **www.eospower.com** **Silent 250 Watt** i **Medical Grade AC-DC Power Supplies** ## **Mechanical Drawing** ## **MFLS250 3 X 5 with Cover kit - Fan** 4EM-21-295 20 39-DE60-42759-002 / A **www.eospower.com**
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →