MACX PL-EX-T-UIREL-UP
RTD Sensor, -200 °C, 850 °C, 50 kohm
- Manufacturer: PHOENIX CONTACT
- Product type: RTD Temperature Sensors
- Resistance: 50kohm
- Sensing Temperature Max: 850°C
- Sensing Temperature Min: -200°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 356.87 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal inputs, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, screw connection, PLd. Replacement part: 2865751 MACX MCR-EX-T-UIREL-UP. Key Commercial Data ~~a~~ Packing unit 1 pc GTIN ~~IE a~~ GTIN 4046356899789 Weight per Piece (excluding packing) 180.000 g ~~a~~ Custom tariff number 85437090 ~~a a~~ Country of origin Germany ~~a~~ Note Made to Order (non-returnable) ## Technical data ## Dimensions |Width|35 mm| |---|---| |Height|99 mm| |Depth|114.5 mm| |Ambient conditions|| |Ambient temperature (operation)|-20 °C ... 65 °C| |Ambient temperature (storage/transport)|-40 °C ... 85 °C| |Maximum altitude|≤ 2000 m| |Permissible humidity (operation)|typ. 5 % ... 95 % (non-condensing)| |Noise immunity|EN 61000-6-2 When being exposed to interference, there may be<br>minimal deviations.| |Shock|15g, according to IEC 60068-2-27| 02/27/2020 Page 1 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Technical data ## Ambient conditions |Vibration (operation)<br>5g, accordance to IEC 60068-2-6| |---| |Input data| |Sensor types (RTD) that can be used<br>Pt, Ni, Cu sensors: 2, 3, 4-wire<br>Sensor types that can be used (TC)<br>B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG<br>Temperature measuring range<br>-200 °C ... 850 °C<br>Input signal range<br>0 Ω ... 50 kΩ<br>Potentiometer resistance range<br>0 Ω ... 50 kΩ<br>Input signal range<br>-1000 mV ... 1000 mV<br>~~==~~| |Output data| |Configurable/programmable<br>Yes<br>Current output signal<br>4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)<br>Max. current output signal<br>22 mA<br>Load/output load current output<br>≤ 600 Ω (20 mA)<br>Behavior in the event of a sensor error<br>according to NE 43 or freely configurable<br>Output name<br>Relay output<br>Output description<br>1 SIL/PL<br>Configurable/programmable<br>Yes<br>Contact type<br>2 PDT<br>Contact material<br>AgSnO2, hard gold-plated<br>Maximum switching voltage<br>250 V AC (250 V DC)<br>Maximum inrush current<br>2 A (250 V AC)<br>2 A (28 V DC)<br>0.2 A (120 V DC)<br>Mechanical service life<br>1x 10<br>5cycles<br>Power supply<br>Supply voltage range<br>24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)<br>Typical current consumption<br>< 100 mA (24 V DC)<br>Power consumption<br>< 2.4 W<br>~~=~~| |General| |Maximum transmission error<br>0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)<br>Maximum temperature coefficient<br>0.01 %/K<br>Step response (0–99%)<br>typ. 1000 ms (With SIL)<br>typ. 700 ms (Without SIL)<br>Status display<br>Green LED (supply voltage, PWR)<br>Red LED, flashing (line, sensor error, ERR)<br>Red LED (module error, ERR)<br>Yellow LED (switching output)<br>~~==~~| |02/27/2020 Page 2 / 12| https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Technical data ## General Degree of pollution 2 ~~a~~ Overvoltage category II ~~a~~ Electromagnetic compatibility Conformance with EMC directive ~~CO~~ Housing material PA 6.6-FR ~~a~~ Color yellow ~~pf~~ Designation Input/output/power supply Electrical isolation 2.5 kV (50 Hz, 1 min., test voltage) ~~fp~~ Designation Input/output ~~a a~~ Electrical isolation 375 V (Peak value in accordance with EN 60079-11) ~~CO~~ Designation Input/power supply ~~a~~ Electrical isolation 375 V (Peak value in accordance with EN 60079-11) ~~pf~~ Designation Input/switching output Electrical isolation 375 V (Peak value in accordance with EN 60079-11) ~~fp a~~ Designation Output/supply 300 Vrms (Rated insulation voltage (overvoltage category II; degree of Electrical isolation pollution 2, safe isolation as per EN 61010-1)) ~~a~~ Conformance CE-compliant ~~pe GO~~ ATEX II (1) G [Ex ia Ga] IIC ~~a~~ II (1) D [Ex ia Da] IIIC ~~a~~ II 3 G Ex nA nC ic IIC T4 Gc X ~~OO~~ IECEx [Ex ia Ga] IIC ~~CO~~ [Ex ia Da] IIIC Ex nA nC ic IIC T4 Gc X ~~pe pf~~ UL, USA/Canada UL 508 Listed SIL 2 ~~a~~ Safety data Max. internal inductance Li negligible Max. internal capacitance Ci 44 nF Max. output voltage Uo 6 V Max. output current Io 7.4 mA Max. output power Po 11 mW Group IIC Max. external inductivity Lo 100 mH Max. external capacitance Co 1.3 µF Group IIC Max. external inductivity Lo 10 mH Max. external capacitance Co 1.7 µF Group IIC Max. external inductivity Lo 1 mH 02/27/2020 Page 3 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 Technical data Safety data Max. external capacitance Co 2.6 µF Group IIC Max. external inductivity Lo 0 mH Max. external capacitance Co 10 µF Group IIB Max. external inductivity Lo 100 mH Max. external capacitance Co 6.8 µF Group IIB Max. external inductivity Lo 10 mH Max. external capacitance Co 9.2 µF Group IIB Max. external inductivity Lo 1 mH Max. external capacitance Co 15 µF Safety-related maximum voltage Um 253 V AC/DC ~~.~~ EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 2 % Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 2 % Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 2 % ~~=~~ Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation 4-way, between input/output/power supply/switching output Shock 15g, according to IEC 60068-2-27 Vibration (operation) 5g, accordance to IEC 60068-2-6 Conformance CE-compliant ATEX II (1) G [Ex ia Ga] IIC II (1) D [Ex ia Da] IIIC II 3 G Ex nA nC ic IIC T4 Gc X ~~__~~ 02/27/2020 Page 4 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Technical data ## Standards and Regulations |IECEx|[Ex ia Ga] IIC| |---|---| ||[Ex ia Da] IIIC| ||Ex nA nC ic IIC T4 Gc X| |UL, USA/Canada|UL 508 Listed| |Group|IIC| ||IIC| ||IIC| ||IIC| ||IIB| ||IIB| ## Environmental Product Compliance |REACh SVHC|Lead 7439-92-1| |---|---| |China RoHS|Environmentally Friendly Use Period = 50| ||For details about hazardous substances go to tab “Downloads”,<br>Category “Manufacturer's declaration”| ## Drawings 02/27/2020 Page 5 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 Block diagram Pictogram 02/27/2020 Page 6 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Classifications ## eCl@ss |eCl@ss 4.0|eCl@ss 4.0|27200200| |---|---|---| |eCl@ss 4.1|eCl@ss 4.1|27200200| |eCl@ss 5.0|eCl@ss 5.0|27200200| |eCl@ss 5.1|eCl@ss 5.1|27200200| |eCl@ss 6.0|eCl@ss 6.0|27200200| |eCl@ss 7.0|eCl@ss 7.0|27200206| |eCl@ss 8.0|eCl@ss 8.0|27200206| |eCl@ss 9.0|eCl@ss 9.0|27210129| ## ETIM |ETIM 2.0|ETIM 2.0|EC001446| |---|---|---| |ETIM 3.0|ETIM 3.0|EC001446| |ETIM 4.0|ETIM 4.0|EC001446| |ETIM 5.0|ETIM 5.0|EC001446| |ETIM 6.0|ETIM 6.0|EC002919| |ETIM 7.0|ETIM 7.0|EC002919| ## UNSPSC |UNSPSC 6.01|UNSPSC 6.01|30211506| |---|---|---| |UNSPSC 7.0901|UNSPSC 7.0901|39121008| |UNSPSC 11|UNSPSC 11|39121008| |UNSPSC 12.01|UNSPSC 12.01|39121008| |UNSPSC 13.2|UNSPSC 13.2|41112105| |UNSPSC 18.0|UNSPSC 18.0|41112105| |UNSPSC 19.0|UNSPSC 19.0|41112105| |UNSPSC 20.0|UNSPSC 20.0|41112105| |UNSPSC 21.0|UNSPSC 21.0|41112105| ## Accessories ## Accessories ## Cradle unit Adapter module - IFS-OP-CRADLE - 2811886 The adapter (IFS-OP-CRADLE) for the operator interface is ideal for use as a remote operator panel and display device for 17.5 mm / 35 mm modules. Can be mounted directly on the DIN rail. Replacement part: 2905872 IFS-BTPROG-ADAPTER. Device marking 02/27/2020 Page 7 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Accessories Plastic label - UC-EMLP (11X9) - 0819291 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 ## Plastic label - UC-EMLP (11X9) YE - 0822602 Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 ## Plastic label - UC-EMLP (11X9) SR - 0828094 Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 ## Plastic label - US-EMLP (11X9) - 0828789 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 ## Plastic label - US-EMLP (11X9) YE - 0828871 Plastic label, Card, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 02/27/2020 Page 8 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Accessories Plastic label - US-EMLP (11X9) SR - 0828872 Plastic label, Card, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 Device marker - LS-EMLP (11X9) WH - 0831678 Device marker, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 Device marker - LS-EMLP (11X9) YE - 0831732 Device marker, Sheet, yellow, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 Device marker - LS-EMLP (11X9) SR - 0831705 Device marker, Sheet, silver, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 ## Insulating sleeve Insulating sleeve - MPS-IH BK - 0201731 Insulating sleeve, color: black 02/27/2020 Page 9 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Accessories Insulating sleeve - MPS-IH GY - 0201728 Insulating sleeve, color: gray Insulating sleeve - MPS-IH GN - 0201702 Insulating sleeve, color: green Insulating sleeve - MPS-IH YE - 0201692 Insulating sleeve, color: yellow Insulating sleeve - MPS-IH BU - 0201689 Insulating sleeve, color: blue ## ~~ee~~ Insulating sleeve - MPS-IH RD - 0201676 Insulating sleeve, color: red ~~me~~ 02/27/2020 Page 10 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Accessories Insulating sleeve - MPS-IH WH - 0201663 Insulating sleeve, color: white ## Labeled device marker Plastic label - UC-EMLP (11X9) CUS - 0824547 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm ## Plastic label - UC-EMLP (11X9) YE CUS - 0824548 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm ## Plastic label - UC-EMLP (11X9) SR CUS - 0828098 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 ## Operator interface Operator interface - IFS-OP-UNIT - 2811899 The operator interface facilitates straightforward parameterization and operation of the MACX MCR(-EX)-...-UI(REL) (-UP) on-site, even without software. Can be snapped onto the 35 mm module. Replacement part: 2905872 IFS-BTPROG-ADAPTER. Plug 02/27/2020 Page 11 / 12 https://www.phoenixcontact.com/gb/products/2904910 ## Temperature measuring transducer - MACX PL-EX-T-UIRELUP - 2904910 ## Accessories Plug - MACX MCR-EX-I20 - 2905679 Connection terminal block for current signals +20 mA ...-20 mA for safe switching of limit values, in combination with MACX...EX-T-UI... temperature transducers. Plug - MACX MCR-EX-CJC - 2925002 Plug for cold junction compensation for thermocouples, for safe switching of limit values, in combination with MACX ...EX-T-UI... temperature transducers. ## Programming adapter Programming adapter - IFS-USB-PROG-ADAPTER - 2811271 Programming adapter with USB interface, for programming with software. The USB driver is included in the software solutions for the products to be programmed, such as measuring transducers or motor managers. ## Test plug terminal block Test plugs - MPS-MT - 0201744 Test plugs, with solder connection up to 1 mm² conductor cross section, color: gray Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 02/27/2020 Page 12 / 12
Updated at February 9, 2023
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →