M1ARM 24-240VAC/DC 60MINS
Analogue Timer, Recycling, 0.5 s, 60 min, 4 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BROYCE CONTROL
- Product type: Analogue Timers - DIN Rail
- Product Range:-; Timer Functions:Recycling; Time Min:0.5s; Time Max:60min; No. of Timing Ranges:4Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:240V; Current Rating Nom:8A; Conn
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 60min
- Time Min: 0.5s
- Timer Output: 1 Changeover Relay
- Product Range: -
- Timer Functions: Recycling
- Current Rating Nom: 8A
- Supply Voltage Max: 240V
- No. of Timing Ranges: 4Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 42.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Type: M1ARM Asymmetrical Recycler - Selectable On or Off first** ## **17.5mm DIN rail housing** **Asymmetrical Recycling Off/On or On/Off (selectable) Multi-voltage supply: 24 - 240V AC / DC** **Selectable time ranges for “On” and “Off” periods (up to 60mins) Separate adjustments for “On” and “Off” periods 1 x SPDT relay output 8A** Dims: to DIN 43880 Terminal Protection to IP20 W. 17.5mm **LED indication of supply and output relay status** - FUNCTION DIAGRAM ## • TECHNICAL SPECIFICATION Supply voltage U: 24 - 240V AC / DC (AC: 48 - 63Hz) Supply variation: 75 - 110% of U Power consumption: ≈ 3VA @ 240V AC 0.8W @ 24V DC Functions: Asymmetrical Recycling - Off first* Asymmetrical Recycling - On first (* selected when external link fitted) Time delay (ton/off) : (selectable) 0.5 - 15, 2 - 60 seconds 0.25 - 8, 2 - 60 minutes Repeat accuracy: ± 0.5% @ constant conditions Reset time: ≈ 100mS Ambient temp: -20 to +60 ° C Relative humidity: +95% Output: SPDT relay Output rating: AC1 250V 8A (2000VA) AC15 250V 5A (no), 3A (nc) DC1 25V 8A (200W) Housing: Orange flame retardant UL94 VO Weight: ≈ 68g Mounting option: On to 35mm symmetric DIN rail to BS5584:1978 (EN50 002, DIN 46277-3) Or direct surface mounting via 2 x M3.5 or 4BA screws using the black clips provided on the rear of the unit Terminal conductor size: ≤ 2 x 2.5mm[2] solid or stranded Approvals: Conforms to IEC. CE and Compliant. iV) **==> picture [281 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> Recycling - On first (A1 & B1 not linked) Recycling - Off first (A1 & B1 linked)<br>oe|< ton |_| toff ton |_| e toff e ee l ¢ toff |<« t on t off > | < t > on |<br>**----- End of picture text -----**<br> - INSTALLATION AND SETTING Installation work must be carried out by qualified personnel. - BEFORE INSTALLATION, ISOLATE THE SUPPLY. - Connect the unit as shown in the diagram below. (Fit external link if required). To set the unit: - Select the “time range” DIP switches for the “on period” and “off period” (see below). - Set the “delay” adjustment as required. (Note the scale is marked as a % of the selected time range). **==> picture [157 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> A B A B A B A B<br>ee On Co Co Co<br>Off i_| i_)| _)_) CHi|<br>0.5 - 15s 2 - 60s 0.25 - 8m 2 - 60m<br>Switch positions shown above for the "Off period".<br>The same positions are used for the "On period"<br>(top two switches).<br>**----- End of picture text -----**<br> - Apply power ( green LED on ). The unit will operate according to the function selected. - During the “on period”, the relay will be energised ( red LED on , contacts 15/18 closed). During the “off period”, the relay will be de-energised ( red LED off , contacts 15/16 closed). Troubleshooting. - If the unit fails to operate, check the wiring is correct and the supply voltage is present and within the operating limits specified. ## • CONNECTION DIAGRAM **==> picture [165 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> -ve Supply +ve<br>* link<br>A1 B1<br>* Fit external link<br>15<br>(A1 to B1) for "Off first"<br>recycling<br>16 18<br>A2<br>**----- End of picture text -----**<br> ## • MOUNTING DETAILS **==> picture [178 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> 89 (excl. clips)<br>45<br>Insert screwdriver —<br>to release clips aoe |<br>\ yo TIN Y<br>\ e y<br>49 59<br>Withdraw clips<br>fully when<br>surface mounting p_<br>93 (+/- 1mm)<br>**----- End of picture text -----**<br> Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England Telephone: +44 (0) 1902 773746 Facsimile: +44 (0) 1902 420639 Email: sales@broycecontrol.com Web: http://www.broycecontrol.com The information provided in this literature is believed to be accurate (subject to change without prior notice); however, use of such information shall be entirely at the user’s own risk. M1ARM-1-A
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →