Image not available
Illustrative purposes only
LMMT/2 12-230V AC/DC
Analogue Timer, LMMT/2, Multifunction, 0.1 s, 100 h, 7 Ranges, 2 Changeover Relays
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BROYCE CONTROL
- Product type: Analogue Timers - DIN Rail
- Product Range:LMMT/2 Series; Timer Functions:Multifunction; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:2 Changeover Relays; Supply Voltage Max:230V; Cur
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.1s
- Timer Output: 2 Changeover Relays
- Product Range: LMMT/2
- Timer Functions: Multifunction
- Current Rating Nom: 8A
- Supply Voltage Max: 230V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 37.13 € |
| Current stock | 50+ |
| Lead time | 30 days |
## _**Type: LMMT/2**_ **Multifunction, Multi-voltage Timer** > Terminal Protection ——s to IP20 Dims: to DIN 43880 W. 17.5mm ***NEW* 17.5mm DIN rail housing 7 Selectable functions (3 Supply Initiated, 4 Switch Initiated) 7 Selectable time ranges (0.1 seconds – 100 hours) Fine adjustment of selected time range** **LED warning indication if function is changed whilst powered Switch initiated functions ideal for use in Watchdog circuits Multi-voltage input (12 – 230V AC/DC) 1 x DPDT relay output 8A Green LED indication for supply / timing status Red LED indication for relay status Conforms to IEC 61812** **==> picture [405 x 271] intentionally omitted <==** **----- Start of picture text -----**<br> • FUNCTION DIAGRAMS • TECHNICAL SPECIFICATION<br>Supply voltage U (A1, A2) :<br>Frequency range:<br>Supply variation:<br>Overvoltage category:<br>Supply A1, A2 a ee Supply A1, A2 ee Supply A1, A2 a oF Power consumption (max.): Rated impulse withstand voltage:<br>AC:<br>DC:<br>Output 15 ve, 1816 =< t tal & DOSU0813 0 Output 15 1186 it t 1 INSU0813 oO Output 15 ee 1816 He t ><ot t >< © t Sal & t >< t RFN081 fo Timing functions (7): Supply initiated: Supply initiated:<br> Switch initiated:<br>Timing ranges (7):<br>Supply A1, A2 otf & & to Supply A1, A2 a 4 f to Supply A1, A2 1 % & & & h o<br>V.F.C. A1, B1 060 1ie — V.F.C. A1, B1 rome) Tf) V.F.C. A1, B1 00es Reset timeAccuracy: Accuracy: [[3]] :<br>Output Output Output Adjustment accuracy:<br>15 1168 oo|0 t #} | 0 t ta DOSWL0813 15 1186 ojt) & t > on DFSW0813 15 1186 oo <>¢ t o/* t > on INSWT0813 Drift with temperature: Repeat accuracy: Drift with voltage: Repeat accuracy: Drift with voltage: Drift with voltage:<br>LED operation: = LED Off LED On LED Flashing External trigger input (A1 > B1) :<br>“Function” Symbol explanation: External loading:<br>Symbol Function [1] Triggered from: Trigger threshold:<br>DO Delay On Operate Supply (A1/A2) Minimum trigger time:<br>Supply A1, A2 i* ¢§ & e & 0 IN Interval Supply (A1/A2) Maximum input frequency:<br>V.F.C. ) RF Symmetrical Recycling (Off/On) Supply (A1/A2) Maximum cable length:<br>A1, B1 ox — . DOb Delay On Switch (A1/B1)<br>Output DN Delay Off Switch (A1/B1) Power on indication / Timing [[2]] :<br>15 ~ o 1168 l =oz t = * t 00 INSWL0813 INbINa Interval*Interval Switch Switch ((A1A1//B1B1)) Ambient temp: Relay status<br>* This function is non-retriggerable<br>**----- End of picture text -----**<br> **==> picture [109 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> • TECHNICAL SPECIFICATION<br>**----- End of picture text -----**<br> Supply voltage U **(A1, A2)** : 12 – 230V AC/DC Frequency range: 48 - 63Hz (AC supplies) Supply variation: AC: +15/-10% DC: +/-15% Overvoltage category: III (IEC 60664) Rated impulse withstand voltage: 4kV (1.2/50µS) IEC 60664 Power consumption (max.): Rated impulse withstand voltage: 12V 24V 110V 230V AC: 0.6VA 0.8VA 2.6VA 6.8VA DC: 0.52W 0.48W 0.94W 1.9W Timing functions (7): Supply initiated: Supply initiated: Delay On (DO), Interval (IN), Symmetrical Recycling Off/On (RF) Switch initiated: Delay On (DOb), Delay Off (DN), Interval (Trailing) (INa), Interval (Leading) (INb) Timing ranges (7): Seconds: Minutes: Hours: 0.1 – 1 0.1 – 1 0.1 – 1 1 – 10 1 – 10 1 – 10 10 - 100 : < 100mS Reset timeAccuracy: Accuracy:[[3]] ± 1% of maximum full scale Adjustment accuracy: < 5% of maximum full scale ± 0.5% at constant conditions (IEC 61812) ± 0.05% / °C Drift with temperature: Repeat accuracy: Drift with voltage: Repeat accuracy: Drift with voltage: Drift with voltage: ± 0.2% / V External trigger input **(A1 > B1)** : Volt Free Contact, Open Collector External loading: Yes, between B1 and A2 (i.e. LED, Relay, Lamp) Trigger threshold: >75% of voltage present between A1 and A2 (auto-set) Minimum trigger time: AC: 60mS DC: 40mS (B1 terminal unloaded) Maximum input frequency: 10 Hz (with 50:50 duty cycle) Maximum cable length: 10m (between Timer and external switching device) Power on indication / Timing[[2]] : Green LED Relay status Red LED Ambient temp: Relay status -20 to +60°C Relative humidity: +95% Output **(15, 16, 18 / 25, 26, 28)** : DPDT relay Output rating: AC1 250V 8A (2000VA) AC15 250V 5A (no), 3A (nc) DC1 25V 8A (200W) Electrical life: ≥ 150,000 ops at rated load Dielectric voltage: 2kV AC (rms) IEC 60947-1 Rated impulse withstand voltage: 4kV (1.2/50µS) IEC 60664 Housing: Orange flame retardant UL94 Weight: ≈ 70g Mounting option: On to 35mm symmetric DIN rail to BS EN 60715 or direct surface mounting via 2 x M3.5 or 4BA screws using the black clips provided on the rear of the unit. Terminal conductor size ≤ 2 x 2.5mm[2] solid or stranded Approvals: Conforms to IEC 61812. ## • _INSTALLATION AND SETTING_ Installation work must be carried out by qualified personnel. - BEFORE INSTALLATION, ISOLATE THE SUPPLY. - Connect the unit as required. ## _Setting the unit._ - Set the “Function” selector ➎ to the required position[1] . - Set the “Range” ➍ to the required position choosing seconds, minutes or hours then set the “Set %” adjustment ➌ as required. The “Set %” is a % of the selected range, so 60% of the 1 – 10 hour range will give 6 hours. - _Applying power._ - Apply power and the green LED ➊ will illuminate or start flashing depending on Function selected. If a Switch initiated function is selected, the LED will begin flashing upon closing of the external input. - The red relay LED ➋ will illuminate to indicate the relay is in the energised state. ## _Note:_ - _1 If the “Function” selector is changed whilst the power is applied, the relay will remain in its current state and the green LED will flash at a faster rate. Power must be removed and re-applied for the new Function to operate._ - _2 In accordance with IEC 61812, the green LED is permitted to extinguish during a voltage dip or momentary interruption of the power supply providing the state of the output relay does not change._ - _3 The dip / interruption (reset) duration and levels are defined in the product standard however, the standard allows for these to be different from the levels actually specified._ > CE, C-tick Cc and RoHS Compliant. EMC: Immunity: EN 61000-6-2 (EN 61000-4-3 10V/m 80MHz - 2.7GHz). Emissions: EN 61000-6-4 **==> picture [542 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> • CONNECTION DIAGRAM • SETTING DETAILS • DIMENSIONS<br>._ ——— N/-ve 1. Power supply status / — —————e , SRE c aeceor 89 (exc. clips)<br>SupplyL/+ve = A1 A2 n Timing (Green) LED 2. Relay output status a ➊ - 67.545 4<br>External B1 Example of external (Red) LED<br>N.O. contact @ ® loads that can beconnected to the 3. “Set %” adjustment RF’ | s ' H |<br>trigger inputsimultaneously. 4. Time delay “Range” ➎<br>15 selector<br>(25) 5. Timing “Function” 0.1-1, 1-100 Insert screwdriverto release clips '<br>/ 1 R selector ➍ s Gre04-1 » \ ' |) +<br>(26)16 (28)18 10 203 ➌<br>a<br>15 = 16 18 = ➋ vice:so-so0100 40°"9080 3 surface mounting @ Withdraw clips fully when )-<br>25 26 28 LMMT/2 le 92 (+/- 1mm) all dimensions in mm. |<br>Relay Lamp<br>66.5<br>49.5<br>29<br>**----- End of picture text -----**<br> Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639 Email: sales@broycecontrol.com Web: www.broycecontrol.com _The Information provided in this literature is believed to be accurate (subject to change without prior notice); however, use of such information shall be entirely at the user’s own risk._ LMMT2-3-A.DOCX 1811
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →