Image not available
Illustrative purposes only
LMMT 12-230V AC/DC
Analogue Timer, L, Multifunction, 0.1 s, 100 h, 7 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BROYCE CONTROL
- Product type: Analogue Timers - DIN Rail
- Product Range:L series; Timer Functions:Multifunction; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:230V; Curren
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.1s
- Timer Output: 1 Changeover Relay
- Product Range: L
- Timer Functions: Multifunction
- Current Rating Nom: 8A
- Supply Voltage Max: 230V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 32.81 € |
| Current stock | 500+ |
| Lead time | 30 days |
**==> picture [175 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> Type: LMMT<br>Multifunction, Multi-voltage Timer<br>**----- End of picture text -----**<br> > Terminal Protection =Q ***NEW* 17.5mm DIN rail housing** > to IP20 Q **7 Selectable functions (3 Supply Initiated, 4 Switch Initiated)** Q **3 Switch initiated functions are re-triggerable (DOb, DN and INb)** Q **7 Selectable time ranges (0.1 seconds – 100 hours)** **Fine adjustment of selected time range** **LED warning indication if function is changed whilst powered Switch initiated functions ideal for use in Watchdog circuits Multi-voltage input (12 – 230V AC/DC) 1 x SPDT relay output 8A** **==> picture [59 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> = [a]<br>**----- End of picture text -----**<br> **Green LED indication for supply / timing status Red LED indication for relay status Conforms to IEC 61812** Dims: to DIN 43880 W. 17.5mm **==> picture [291 x 271] intentionally omitted <==** **----- Start of picture text -----**<br> • FUNCTION DIAGRAMS<br>Supply A1, A2 ay i ei e : 6 Supply A1, A2 ah i ei e ft 0 Supply A1, A2 0 e ri l<br>Output Output Output<br>18 18 18<br>15 16 15 16 15 16<br>LS t DOSU0813 t INSU0813 t t t t t RFN081<br>Supply A1, A2 Supply A1, A2 Supply A1, A2<br>V.F.C. A1, B1 oo ay ee ee V.F.C. A1, B1 oo I V.F.C. A1, B1 oo [|<br>Output Output Output<br>15 ~- 1186 oo} il 0 t >=|70 t >=to DOSWL0813 15 ~ - 1186 Oo} t oO]> <t |) <> t DFSW0518 2 15 ~o 1186 oo|e=| t []0/00 . t INSWT0813<br>LED operation: LED Off LED On LED Flashing<br>“Function” Symbol explanation:<br>Symbol Function [1] Triggered from:<br>DO Delay On Operate Supply (A1/A2)<br>Supply A1, A2 i t & & & to IN Interval Supply (A1/A2)<br>V.F.C. A1, B1 fom) 0 DObRF Symmetrical RecDelayy Oncling (Off/On) SuSwitch pply ((A1A1//B1A2))<br>Output 18 00) & O) | a8 INaDN DelaInterval*y Off Switch Switch ((A1A1//B1B1))<br>15 _ 16 t t INSWL0813 INb Interval Switch (A1/B1)<br>< > * This function is non-retriggerable<br>**----- End of picture text -----**<br> ## • _TECHNICAL SPECIFICATION_ **==> picture [238 x 364] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Supply voltage U|(A1, A2)|:|12 – 230V AC/DC| |Frequency range:|48 - 63Hz (AC supplies)| |Supply variation:|+/ - 15%| |Overvoltage category:|III (IEC 60664)| |Rated impulse withstand voltage:|4kV (1.2/50µS) IEC 60664| |Power consumption (max.):|12V|24V|110V|230V| |AC:|0.3VA|0.4VA|1.3VA|3.4VA| |DC:|0.26W|0.24W|0.47W|0.95W| |Timing functions (7):| |Supply initiated:|Delay On (DO), Interval (IN),| |Symmetrical Recycling Off/On (RF)| |Switch initiated:|Delay On (DOb), Delay Off (DN),|Interval (Trailing) (INa),| |Interval (Leading) (INb)| |Timing ranges (7):|Seconds:|Minutes:|Hours:| |0.1 – 1|0.1 – 1|0.1 – 1| |1 – 10|1 – 10|1 – 10| |10 - 100| |Reset time:|100ms| |Accuracy:|± 1% of maximum full scale| |Adjustment accuracy:|< 5% of maximum full scale| |Repeat accuracy:|± 0.5% at constant conditions (IEC 61812)| |Drift with temperature:|± 0.05% / °C| |Drift with voltage:|± 0.2% / V| |External trigger input|(A1 > B1)|:|Volt Free Contact, Open Collector| |External loading:|Yes, between B1 and A2 (i.e. LED, Relay, Lamp)| |Trigger threshold:|>75% of voltage present between A1 and A2 (auto-set)| |Minimum trigger time:|AC: 60ms DC: 40ms (B1 terminal unloaded)| |Maximum input frequency:|10 Hz (with 50:50 duty cycle)| |Maximum cable length:|10m (between Timer and external switching device)| |Power on indication / Timing|[2]|:|Green LED| |Relay status|Red LED| |Ambient temp:|-20 to +60°C| |Relative humidity:|+95%| |Output|(15, 16, 18)|:|SPDT relay| |Output rating:|AC1|250V 8A (2000VA)| |AC15|250V 5A (no), 3A (nc)| |DC1|25V 8A (200W)| |Electrical life:|≥ 150,000 ops at rated load| |Dielectric voltage:|2kV AC (rms) IEC 60947-1| |Rated impulse withstand voltage:|4kV (1.2/50µS) IEC 60664| |Housing:|Orange flame retardant UL94| |Weight:|≈ 60g| |Mounting option:|On to 35mm symmetric DIN rail to BS EN 60715| |or direct surface mounting via 2 x M3.5 or 4BA screws| |using the black clips provided on the rear of the unit.| |Terminal conductor size|≤ 2 x 2.5mm|[2]|solid or stranded| |Approvals:|Conforms to IEC 61812.| **----- End of picture text -----**<br> ## • _INSTALLATION AND SETTING_ Installation work must be carried out by qualified personnel. - BEFORE INSTALLATION, ISOLATE THE SUPPLY. - Connect the unit as required. ## _Setting the unit._ - Set the “Function” selector ➎ to the required position[1] . - Set the “Range” ➍ to the required position (depending on whether seconds, minutes or hours are required), then set the “Set %” adjustment ➌ as required. The “Set %” is a % of the selected range, so 60% of the 1 – 10 hour range will give 6 hours. ## _Applying power._ - Apply power and the green LED ➊ will illuminate or start flashing depending on Function selected. If a Switch initiated function is selected, the LED will begin flashing upon closing of the external input. - The red relay LED ➋ will illuminate to indicate the relay is in the energised state. _Note:_ - _1 If the “Function” selector is changed whilst the power is applied, the relay will remain in its current state and the green LED will flash at a faster rate. Power must be removed and re-applied for the new Function to operate._ - _2 In accordance with IEC 61812, the green LED is permitted to extinguish during a voltage dip or momentary interruption of the power supply providing the state of the output relay does not change. The dip / interruption duration and levels are defined in the product standard._ CE, C-tick and RoHS Compliant. EMC: Immunity: EN 61000-6-2 (EN 61000-4-3 10V/m 80MHz - 2.7GHz). Emissions: EN 61000-6-4 ## • _CONNECTION DIAGRAM_ **==> picture [502 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> • SETTING DETAILS • DIMENSIONS<br>N/-ve 1. Power supply status / SPROVGE 89 (exc. clips)<br>SupplyL/+ve 1 ee A1 B1 . Timing (Green) LED 2. Relay output status at ➊ kK ; 67.545 1———<br>External 15 (Red) LED<br>N.O. contact 3. “Set %” adjustment<br>Example of externalloads that can be ~ 4. Time delay “Range” selector ➎ i) DOb] & as<br>15 connected to the 5. Timing “Function” Insert screwdriver<br>R trigger inputsimultaneously. selector DR AG0141 o to release clips i<br>) ➍ 0.1-4, 1-10 \ '<br>16 18 40-100 140°" ➌<br>10 2035<br>16 18 Withdraw clips fully when<br>➋ surface mounting<br>A2 x 100 9080 ‘ani le 92 (+/- 1mm) all dimensions in mm »|<br>Relay Lamp<br>66.5<br>49.5<br>29<br>**----- End of picture text -----**<br> Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639 Email: sales@broycecontrol.com Web: www.broycecontrol.com _The Information provided in this literature is believed to be accurate (subject to change without prior notice); however, use of such information shall be entirely at the user’s own risk._ LMMT-3-A.DOCX 1804
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →