LEDO/2 12-230V AC/DC
Analogue Timer, LEDO/2, Delay-On-Operate, 0.1 s, 100 h, 7 Ranges, 2 Changeover Relays
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BROYCE CONTROL
- Product type: Analogue Timers - DIN Rail
- Product Range:LEDO/2 Series; Timer Functions:Delay-On-Operate; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:2 Changeover Relays; Supply Voltage Max:230
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.1s
- Timer Output: 2 Changeover Relays
- Product Range: LEDO/2
- Timer Functions: Delay-On-Operate
- Current Rating Nom: 8A
- Supply Voltage Max: 230V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 31.89 € |
| Current stock | 25+ |
| Lead time | 30 days |
**Delay On Operate, Multi-voltage Timer** ## S CONTROL ## _**Type: LEDO/2**_ **==> picture [262 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Protection ———s Q *NEW* 17.5mm DIN rail housing<br>to IP20 Q Supply Initiated Delay On Operate Delay On Operate timing function<br>z a<br>Q Fine adjustment of selected time range<br>Multi-voltage input (12 – 230V AC/DC)<br>oll<br>1 x DPDT relay output 8A<br>Q<br>“3! a Red LED indication for relay status<br>Conforms to IEC 61812<br>Dims: to DIN<br>=" Leno<br>43880<br>W. 17.5mm<br>**----- End of picture text -----**<br> **Supply Initiated Delay On Operate Delay On Operate timing function 7 Selectable time ranges (0.1 seconds – 100 hours) Fine adjustment of selected time range Multi-voltage input (12 – 230V AC/DC) 1 x DPDT relay output 8A** **Green LED indication for supply / timing status Red LED indication for relay status Conforms to IEC 61812** **==> picture [88 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> • FUNCTION DIAGRAM<br>**----- End of picture text -----**<br> **==> picture [233 x 355] intentionally omitted <==** **----- Start of picture text -----**<br> • TECHNICAL SPECIFICATION<br>Supply voltage U (A1, A2) : 12 – 230V AC/DC<br>Frequency range: 48 - 63Hz (AC supplies)<br>Supply variation: AC: +15/- 10% DC: +/-15%<br>Overvoltage category: III (IEC 60664)<br>Rated impulse withstand voltage: 4kV (1.2/50µS) IEC 60664<br>Power consumption (max.): 12V 24V 110V 230V<br>AC: 0.6VA 0.8VA 2.6VA 6.8VA<br>DC: 0.52W 0.48W 0.94W 1.9W<br>Timing function: Delay On Operate (Supply Initiated)<br>Timing ranges (7): Seconds: Minutes: Hours:<br>0.1 – 1 0.1 – 1 0.1 – 1<br>1 – 10 1 – 10 1 – 10<br>10 - 100<br>Reset time [2] : <100mS<br>Accuracy: ± 1% of maximum full scale<br>Adjustment accuracy: < 5% of maximum full scale<br>Repeat accuracy: ± 0.5% at constant conditions (IEC 61812)<br>Drift with temperature: ± 0.05% / °C<br>Drift with voltage: ± 0.2% / V<br>Power on indication / Timing [1] : Green LED<br>Relay status Red LED<br>Ambient temp: -20 to +60°C<br>Relative humidity: +95%<br>Output (15, 16, 18/25, 26, 28) : DPDT relay<br>Output rating: AC1 250V 8A (2000VA)<br>AC15 250V 5A (no), 3A (nc)<br>DC1 25V 8A (200W)<br>Electrical life: ≥ 150,000 ops at rated load<br>Dielectric voltage: 2kV AC (rms) IEC 60947-1<br>Rated impulse withstand voltage: 4kV (1.2/50µS) IEC 60664<br>Housing: Orange flame retardant UL94<br>Weight: ≈ 70g<br>Mounting option: On to 35mm symmetric DIN rail to BS EN 60715<br>or direct surface mounting via 2 x M3.5 or 4BA screws<br>using the black clips provided on the rear of the unit.<br>Terminal conductor size ≤ 2 x 2.5mm [2] solid or stranded<br>Approvals: Conforms to IEC 61812.<br>e(U)us LISTED IND. CONT.111187 EQ.<br>CE, C-tick © and RoHS Compliant.<br>EMC: Immunity: EN 61000-6-2 (EN 61000-4-3 10V/m<br>80MHz - 2.7GHz)<br>Emissions: EN 61000-6-4<br>**----- End of picture text -----**<br> **==> picture [147 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> Supply<br>A1, A2<br>Output u<br>18 (28)<br>15 (25) o N<br>16 (26)<br>t<br>LED operation:<br>vl,<br>LED Off LED On LED Flashing<br>**----- End of picture text -----**<br> **==> picture [19 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> DO2SU0715<br>**----- End of picture text -----**<br> **==> picture [114 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> • INSTALLATION AND SETTING<br>**----- End of picture text -----**<br> - Installation work must be carried out by qualified personnel. - BEFORE INSTALLATION, ISOLATE THE SUPPLY. - Connect the unit as required. - _Setting the unit._ - Set the “Range” ➍ to the required position (depending on whether seconds, minutes or hours are required). - Set the “Set %” adjustment ➌ as required. The “Set %” is a % of the selected range; so for example, a 30% setting on the 1 – 10 hour range will give 3 hours. - _Applying power._ - Apply power across terminals “A1” and “A2” and the green LED ➊ will start flashing indicating timing in progress. - The relay will remain de-energised (contacts **15** / **16** and **25 / 26** closed, **15** / **18** and **25 / 28** open) and red LED ➋ extinguished. - After the delay period “t” has elapsed, the relay will energise (contacts **15** / **16** and **25 / 26** open, **15** / **18** and **25 / 28** closed) and the red LED will illuminate. - The green LED will remain permanently lit. - The whole timing process is repeated by removing and re-applying power. ## _Note:_ - _1 In accordance with IEC 61812, the green LED is permitted to extinguish during a voltage dip or momentary interruption of the power supply providing the state of the output relay does not change._ - _2 The dip / interruption (reset) duration and levels are defined in the product standard however, the standard allows for these to be different from the levels actually specified._ **==> picture [362 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> • SETTING DETAILS • DIMENSIONS<br>1. Power supply status / Timing (Green) LED 2. Relay output status t SPRONGE ➊ | ik 89 (exc. clips)67.545 q o<br>(Red) LED aol - pt<br>3. “Set %” adjustment<br>4. Time delay “Range”<br>selector<br>Insert screwdriver<br>to release clips<br>ot 1100 : \ |<br>➍<br>➌<br>40-400e730 10"4 sl @ Withdraw clips )<br>fully when<br>➋ vie" 80 i surface mounting : |<br>LEDOI2 i 92 (+/- 1mm) all dimensions in mm. 1<br>LEDO_2-2-A.DOCX<br>1811<br>66.5<br>49.5<br>29<br>**----- End of picture text -----**<br> **==> picture [98 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> • CONNECTION DIAGRAM<br>**----- End of picture text -----**<br> Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639 Email: sales@broycecontrol.com Web: www.broycecontrol.com _The Information provided in this literature is believed to be accurate (subject to change without prior notice); however, use of such information shall be entirely at the user’s own risk._
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →