Image not available
Illustrative purposes only
LA 305-S
Current Transducer, LA Series, 300A, -500A to 500A, 0.8 %, Closed Loop Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Closed Loop; Supply Voltage DC Min:-; Supply Voltage DC Max:-; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:-; Accuracy %:0.8%; Product Range:-;
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 0.8%
- Accuracy %: 0.8%
- Product Range: LA305 Series
- Primary Current: 300A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Closed Loop
- Supply Voltage Range: ± 12V to ± 15V
- Secondary Signal Type: 120mA
- Current Sensor Technology: Closed Loop, Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -10°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 115.38 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **Current Transducer LA 305-S** ## **I = 300 A** PN For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). COM 16173 LANT ## **Electrical data** |**I**PN|Primary nominal current rms|||300||||A| |---|---|---|---|---|---|---|---|---| |**I**PM|Primary current, measuring range|Primary current, measuring range||0 .. ± 500||||A| ||||**T**A= 70°C|||**T**A= 85°C||| |**R**M|Measuring resistance||**R**M min**R**M max|||M max**R**M min|M min**R**M max|M max| ||with ± 12 V<br>@ ± 300 Amax||0|52||0|50|50<br>Ω| ||@ ± 500 Amax||0|17||0|15|15<br>Ω| ||with ± 15 V<br>@ ± 300 Amax||0|75||5|73|73<br>Ω| ||@ ± 500 Amax||0|31||5|29|29<br>Ω| |**I**SN|Secondary nominal current rms|Secondary nominal current rms||120||||mA| |**K**N|Conversion ratio|||1 : 2500||||| |**V**C|Supply voltage (± 5 %)|||± 12 .. 15|± 12 .. 15|||V| |**I**C|Current consumption|||20(@ ± 15 V) +|||(@ ± 15 V) +**I**SmA|mA| |**Accuracy - Dynamic performance data**||||||||| |**X**G|Overall accuracy @**I**PN,**T**A= 25°C|||± 0.8|± 0.8|± 0.8||%| |εL|Linearity error|||< 0.1|< 0.1|< 0.1||%| |||||Typ||Max||| |**I**O<br>**I**OM|Offset current @**I**P= 0,**T**A= 25°C<br>Magnetic offset current1)@**I**P= 0 and specified|= 25°C<br>= 0 and specified|= 0 and specified**R**M,|||± 0.20|± 0.20|mA<br>mA| ||after an overload of 3 x||after an overload of 3 x**I**PN|||± 0.40|± 0.40|mA| |**I**OT|Temperature variation of**I**O|- 10°C .. + 85°C||± 0.12 ± 0.30|± 0.12 ± 0.30|± 0.12 ± 0.30|± 0.12 ± 0.30|mA| |**t**ra|Reaction time @ 10 % of**I**PN|||< 500|< 500|< 500||ns| |**t**r|Response time2)@ 90 % of**I**PNstep|||< 1||||µs| |**di/dt**|di/dt accurately followed|||> 100|> 100|> 100|A/µs|| |**BW**|Frequency bandwidth (- 3 dB)|||DC .. 100||||kHz| |**General data**||||||||| |**T**A|Ambient operating temperature|||- 10 .. + 85||||°C| |**T**S|Ambient storage temperature|||- 40 .. + 90||||°C| |**R**S|Secondary coil resistance|@**T**A= 70°C||35||||Ω| |||@**T**A= 85°C||37||||Ω| |**_m_**|Mass|||200||||g| ||Standards|||EN 50178: 1997||||| ## **Features** - ●Closed loop (compensated) current transducer using the Hall effect - ●Isolated plastic case recognized according to UL 94-V0. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. - Notes: 1) The result of the coercive force (Hc) of the magnetic circuit 2) With a di/dt of 100 A/µs. Page 1/3 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 110203/9 ## **Current Transducer LA 305-S** |**Isolation characteristics**|**Isolation characteristics**||| |---|---|---|---| |**V**d|Rms voltage for AC isolation test, 50 Hz, 1 min|6|kV| |**V**w|Impulse withstand voltage 1.2/50 µs|20|kV| |||Min|| |**dCp**|Creepage distance|27|mm| |**dCI**|Clearance distance|26.5|mm| |**CTI**|Comparative Tracking Index (group IIIa)|225|| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |**dCp**,**dCI**,<br>**V**w|Rated insulation voltage|Nominal voltage| |Single insulation|2500 V|2500 V| |Reinforced insulation|1250 V|1250 V| According VDE 0160 (1994): single insulation 3500 V Reinforced insulation 1750 V ## **Safety** This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 110203/9 ## **Dimensions LA 305-S** (in mm) ## **Connection** ## **Mechanical characteristics** - ●General tolerance ●General tolerance ± 0.5 mm ●Transducer fastening 2 holes Ø 5.5 mm 2 M5 steel screws Recommended fastening torque 4 Nm ●Primary through-hole 25.5 x 25.5 mm ●Connection of secondary MOLEX 5046 4 pins tin plated ## **Remarks** - **I** S is positive when **I** P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 100°C. - ●Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 110203/9
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →