LA 150-P
Current Transducer, Closed Loop Hall Effect, AC/DC/Pulsed, 150A, Analogue-75mA, ± 12V to 15V Supply
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 0.5%
- Product Range: LA150 Series
- Primary Current: 150A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Analogue
- Supply Voltage Range: ± 12V to 15V
- Secondary Signal Type: 75mA
- Current Sensor Technology: Closed Loop Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 27.49 € |
| Current stock | 50+ |
| Lead time | 30 days |
## **Current Transducer LA 150-P** ## _I_ **= 150 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## **Features** ## ~~**Electrical data**~~ |_I_P N|Primary nominal RMS current|150|A| |---|---|---|---| |_I_P M|Primary current, measuring range|0 ... ±212|A| |_R_M|Measuring resistance @ 85 °C|_R_M min _R_M max|| ||with ±12 V<br>@ ±150 Amax|0<br>40|Ω| ||@ ±212 Amax<br>with ±15 V<br>@ ±150 Amax|0<br>3<br>0<br>78|Ω<br>Ω| |_I_S N<br>_N_P/_N_S<br>_U_C<br>_I_C|@ ±212 Amax<br>Secondary nominal RMS current<br>Conversion ratio<br>Supply voltage (±5 %)<br>Current consumption|0<br>30<br>Ω<br>75<br>mA<br>1 : 2000<br>±12 ... 15<br>V<br>10 (@ ±15 V) +_I_SmA|| ## ~~**Accuracy - Dynamic performance data** Po~~ _ε_ Error @ _I_ P N, _T_ A = 25 °C < 0.5 % _ε_ L Linearity error < 0.1 % Typ Max _I_ O E Electrical offset current @ _I_ P = 0, _T_ A = 25 °C ±0.10 mA _I_ O M Magnetic offset current @ _I_ P = 0 and specified _R_ M, after an overload of 3 × _I_ P N ±0.25 mA _I_ O _T_ Temperature variation of _I_ O -40 °C ... +85 °C ±0.15 ±0.30 mA _t_ D 10 Delay time to 10 % of the final output value for _I_ P N < 300 ns _t_ D 90 Delay time[1)] to 90 % of the final output value for _I_ P N < 500 ns _BW_ Frequency bandwidth (−1 dB) DC ... 150 kHz ## ~~**General data** Lo~~ |_T_A<br>_T_A st<br>_R_S|A st|Ambient operating temperature<br>Ambient storage temperature<br>Resistance of secondary winding @_T_A= 25 °C|−40 ... +85<br>−40 ... +90<br>64 ±2|°C<br>°C<br>Ω| |---|---|---|---|---| |_m_||Mass|< 25|g| |||Standards|EN 50178: 1997|| ||||UL 508: 2010|| - ●Closed loop (compensated) current transducer using the Hall effect - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. Note:[1)] With a d _i_ /d _t_ of 100 A/µs. N° 52.B4.39.000.0 Page 1/4 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 24July2024/Version 5 ## **Current Transducer LA 150-P** ## **UL 508:Ratings and assumptions of certification** File # E189713 Volume: 2 Section: 1 ## **Standards** - ●CSA C22.2 NO. 14 - 10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 - ●UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15. **==> picture [511 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Value<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Value**| |---|---|---|---| ||||| |Primary potential involved||V AC/DC|600| |Max surrounding air temperature|_T_A|°C|85| |Primary current|_I_P|A|0 to 150| |Secondary supply voltage|_U_C|V DC|±12 ... 15| |Output signal|_I_S N|mA|65| ## **Conditions of acceptability** When installed in the end-use equiment, consideration shall be given to the following _:_ - _1 - These devices must be mounted in a suitable end-use enclosure._ - _2 - The terminals have not been evaluated for field wiring._ - _3 - The LA 150 series are intended to be mounted on the printed wiring board of the end-use equipment (with a minimum CTI of 100)._ - _4 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other than through the grounding means)._ - _5 - Base on results of temperature tests, in the end use application, a maximum of 100 °C cannot be exceeded at soldering point between primary coil pin and soldering point of on the primary bus bar (corrected to the appropriate evaludated max. surrounding air)._ ## **Marking** Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under UL’s Follow-Up Service.Always look for the Mark on the product. Page 2/4 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 24July2024/Version 5 ## **Current Transducer LA 150-P** ||~~**Insulation coordination**~~||| |---|---|---|---| |_U_d|RMS voltage for AC insulation test, 50 Hz/1 min|4.3|kV| |_U_Ni|Impulse withstand voltage 1.2/50 µs|8|kV| |_U_t|Partial discharge RMS test voltage (_q_m< 10 pC)|1.3|kV| |||Min|| |_d_Cp|Creepage distance|8|mm| |_d_CI|Clearance|8|mm| |_CTI_|Comparative tracking index (group I)|600|| ## **Applications examples** According to **EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp**,**_d_CI**,**_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|1000 V|1000 V| |Reinforced insulation|600 V|400 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. ## Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 3/4 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 24July2024/Version 5 ## **Dimensions LA 150-P** (in mm) **==> picture [65 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> d CI d Cp<br>**----- End of picture text -----**<br> **==> picture [103 x 32] intentionally omitted <==** ## **Connection** **==> picture [145 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> I P<br>I S R M +U C<br>-U C<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance ±0.5 mm 13.5 × 10 mm - ●Primary through-hole - ●Fastening & connection of secondary 3 pins 0.6 × 0.6 mm Recommended PCB hole ⌀ 1.1 mm ## **Remarks** - _I_ S is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 100 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: https://www.lem.com/en/fle/3137/download - ●Dynamic performances (d _i_ /d _t_ and delay time) are best with a single bar completely filling the primary hole - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 4/4 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 24July2024/Version 5
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →