Current Transducer, LA Series, 100A, -160A to 160A, 0.7 %, Closed Loop Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Closed Loop; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-160A to 160A; Current Measuring Range AC:-160A to 160A; Response Time:1µs; Accur
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 0.45%
- Accuracy %: 0.7%
- Product Range: LA100P Series
- Response Time: 1µs
- Primary Current: 100A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Closed Loop
- Supply Voltage Range: ± 12V to ± 15V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Closed Loop, Hall Effect
- Operating Temperature Max: 70°C
- Operating Temperature Min: 25°C
- Current Measuring Range AC: -160A to 160A
- Current Measuring Range DC: -160A to 160A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 41.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer LA 100-P/SP13** ## _I_ **= 100 A** PN For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data**~~ |_I_PN<br>_I_PM|Primary nominal rms current<br>Primary current, measuring range|100<br>0 .. ±160|A<br>A| |---|---|---|---| |_R_M|Measuring resistance @ 70 °C||| |||_R_M min _R_M max|| ||with ±12 V<br>@ ±100 Amax|10<br>65|Ω| ||@ ±160 Amax|10<br>30|Ω| ||with ±15 V<br>@ ±100 Amax|40<br>95|Ω| |_I_SN|@ ±160 Amax<br>Secondary nominal rms current|40<br>50<br>100|Ω<br>mA| |_K_N<br>_U_C<br>_I_C|Conversion ratio<br>Supply voltage (±5 %)<br>Current consumption|1 : 1000<br>±12 .. 15<br>10(@ ±15 V) +_I_S|V<br>mA| |**Accuracy - Dynamic performance data**|||| |_X_<br>_ε_L<br>_I_O<br>_I_OM<br>_I_O_T_<br>_t_ra|Accuracy @_I_PN,_T_A= 25 °C<br>@ ±15 V (±5 %)<br>@ ±12 .. 15 V (±5 %)<br>Linearity error<br>Offset current @_I_P= 0,_T_A= 25 °C<br>Magnetic offset current1)@_I_P= 0 and specified_R_M,<br>after an overload of 3 ×_I_PN<br>Temperature variation of_I_O<br>-25 °C .. +70 °C<br>Reaction time|±0.45<br>±0.70<br>< 0.15<br>Typ<br>Max<br>±0.2<br>±0.3<br>±0.1<br>±0.5<br><500|%<br>%<br>%<br>mA<br>mA<br>mA<br>ns| |_t_r|Step response time2)to 90 % of_I_PN|<1|µs| |d_i/_d_t_|d_i_/d_t_accurately followed|>200|A/µs| |_BW_|Frequency bandwidth (-1 dB)|DC .. 200|kHz| |~~**General data**~~|||| |_T_A<br>_T_S<br>_R_S<br>_m_|Ambient operating temperature<br>Ambient storage temperature<br>Resistance of secondary winding @_T_A= 70 °C<br>Mass<br>Standards|-25 .. +70<br>°C<br>-40 .. +90<br>°C<br>25<br>Ω<br>18<br>g<br>EN 50178: 1997<br>UL 508: 2010|| Notes:[1)] Result of the coercive field of the magnetic circuit - 2) With a d _i_ /d _t_ of 100A/ µs. ## **Features** - ●Closed loop (compensated) current transducer using the Hall effect - ●Insulating plastic case recognized according to UL 94-V0. ## **Special features** - _I_ PM = 0 .. ±160 A - _K_ N = 1 : 1000 - _T_ A = -25 °C .. +70 °C. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. N° 97.09.34.013.0 Page 1/3 3February2015/version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com ## **Current Transducer LA 100-P/SP13** |~~**Insulation coordination**~~|~~**Insulation coordination**~~||| |---|---|---|---| |_U_d|Rms voltage for AC insulation test, 50 Hz/1 min|2.5|kV| |_Û_W|Impulse withstand voltage 1.2/50 µs|4.5|kV| |||Min|| |_d_Cp|Creepage distance1)|3.8|mm| |_d_CI|Clearance2)|3.8|mm| |_CTI_|Comparative tracking index (group I)|600|| Notes:[1)] Distance between hole busbar and winding 2) Direct distance between hole busbar and winding. ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp,_d_CI,_Û_W|Rated insulation voltage|Nominal voltage| |Basic insulation|300 V|300 V| |Reinforced insulation|150 V|150 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 3February2015/version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com ## **Dimensions LA 100-P/SP13** (in mm) **==> picture [511 x 372] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P<br>I S R M<br>U C<br>U C d Cl d Cp<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance - ●General tolerance ±0.2 mm ●Primary through-hole 12.7 × 7 mm ●Fastening & connection of secondary 3 pins 0.6 × 0.7 mm - ●Recommended PCB hole 1.2 mm ## **Remarks** - _I_ S is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 100 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **Products/Product Documentation** . - ●Dynamic performances (d _i_ /d _t_ and response time) are best - with a single bar completely filling the primary hole. - ●In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. Page 3/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 3February2015/version 5 www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →