K50LIBXXPQ
LED Indicator, Blue, Steady, 30 VDC, IP67/IP69K, -40 to 50 °C, 50 mm Dia, 69 mm External Height
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (25-Jun-2025)
- Power Rating: -
- Lens Diameter: 50mm
- Product Range: K50 Core Series
- External Height: 69mm
- IP / NEMA Rating: IP67, IP69K
- Module Lens Colour: Blue
- Supply Voltage VAC: -
- Supply Voltage VDC: 30V
- Visual Signal Type: Steady
- Operating Temperature Max: 50°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 115.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
K30L and K50L Intrinsically Safe Indicators
## Datasheet
- For use in hazardous areas with suitable zener barriers or galvanic isolators
- • ATEX, CSA c/us, UKCA, and IECEx • Fully sealed and rated to IP67/IP69K per DIN 40050-9 • 1-, 2-, or 3-color models available with 5 available colors
|Models||||
|---|---|---|---|
||Color|||
|Family|2<br>1|3|Input<br>Connection|
|K30L<br>G<br>R<br>I<br>Q<br>Y<br>P<br>oe||||
|K30L|G = Green<br>I = Ex ia||Blank = 2 m Integral PVC Cable<br>P = PNP|
|K50L|R = Red||Q = Integral 4-pin M12 Quick|
||Y = Yellow||Disconnect (K50L only)*|
||B = Blue||QP = 150 mm (5.9 in) cable with|
||W = White||4-pin M12 Quick Disconnect|
||X = Not Used||W/XX = XX ft. Integral PVC Cable|
||||*Models with a quick disconnect require a mating cordset|
|K30L Models<br>Model<br>K30LIGXXPQP<br>K30LIYXXPQP<br>K30LIRXXPQP<br>K30LIBXXPQP<br>K30LIWXXPQP<br>K30LIGRXPQP<br>K30LIGYXPQP<br>K30LIRYXPQP<br>K30LIGRYPQP|LED Function<br>1 Color: Green<br>1 Color: Yellow<br>1 Color: Red<br>1 Color: Blue<br>1 Color: White<br>2 Color: Green, Red<br>2 Color: Green, Yellow<br>2 Color: Red, Yellow<br>3 Color: Green, Red, Yellow||K50L Models<br>Model(1)<br>LED Function<br>K50LIGXXPQ<br>1 Color: Green<br>K50LIYXXPQ<br>1 Color: Yellow<br>K50LIRXXPQ<br>1 Color: Red<br>K50LIBXXPQ<br>1 Color: Blue<br>K50LIWXXPQ<br>1 Color: White<br>K50LIGRXPQ<br>2 Color: Green, Red<br>K50LIGYXPQ<br>2 Color: Green, Yellow<br>K50LIRYXPQ<br>2 Color: Red, Yellow<br>K50LIGRYPQ<br>3 Color: Green, Red, Yellow|
(1) To order the 150 mm (6 in) PVC cable model with a 4-pin M12 quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, K50LIGXXPQP. Models with a quick disconnect require a mating cordset.
Original Instructions 04-Sep-25
© Banner Engineering Corp. All rights reserved.
www.bannerengineering.com
p/n: 172445 Rev. G
K30L and K50L Intrinsically Safe Indicators
## Installation Instructions
## Ex/HazLoc Applications
## WARNING:
- Explosive Atmospheres/Hazardous Locations
- It is the user's responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relating to the installation and use of this device in any particular application are satisfied. This device must be installed by a Qualified Person[(2)] , in accordance with this document and applicable regulations.
- WARNING: • Explosion Hazard • Do not disconnect equipment unless the power has been switched off or the area is known to be nonhazardous.
WARNING:
- Electrostatic Discharge (ESD) Specific Conditions for Safe Use
- • Parts of the enclosure are non-conducting and can generate an ignition-capable level of ESD. • To reduce the risk of ignition due to electrostatic discharge, avoid contact with the equipment while an explosive atmosphere is present.
- • Clean the equipment with only a damp cloth.
## Specific Conditions for Use and General Notes
- See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations, electrical connections and certifications.
- In addition to the warning above concerning user responsibility, the installation must comply with the following:
- All installations must comply with all manufacturer's instructions.
- ◦ U.S. Installations: The relevant requirements of the National Electrical Code® (ANSI/NFPA-70 (NEC®) and when appropriate ANSI/ISA-RP12.06.01 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations.
- Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1).
- ATEX and IECEx Installations: The relevant requirements of EN IEC 60079-14 and applicable National regulations.
- ◦ For quick disconnect (QD) models only: Use Banner MQDC-4## cordsets (see "Cordsets" on page 6), or suitable M12 quick disconnect cordsets with threaded retaining nut (see "Specifications" on page 4). The cordset must be securely fastened using the M12×1 quick disconnect retaining nut to prevent disconnection. Maximum connector torque: 6 ft·lbs.
- Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with non-factory components may adversely affect the safe use of the system.
- Approved Apparatus entity parameters must meet the following requirements:
- Voc or Vt ≤ Vmax
- ◦ Ca ≥ Ci + Ccable ◦ Isc or It ≤ Imax ◦ La ≥ Li + Lcable
- Device and Cable Entity Parameters: See "Wiring Diagram" on page 3 and "Configuration" on page 3
- The ambient operating temperature range of the device: ◦ EPL Ga & Ma:
- Pi = 2.8W: Ta = –40 °C to +50 °C (–40 °F to +122 °F)
- ▪ Pi = 3.4W: Ta = –40 °C to +40 °C (–40 °F to +104 °F)
- EPL Da: ▪ Pi = 2.2W: Ta = –40 °C to +50 °C (–40 °F to +122 °F) ▪ Pi = 2.7W: Ta = –40 °C to +40 °C (–40 °F to +104 °F)
- For intrinsically safe installations, device must be used with certified intrinsically safe switching amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits that limit supply voltage and current in the event of failures.
- Intrinsic safety ground, if required for the Associated Apparatus, shall be less than 1 ohm.
- The ingress protection (for example, IP rating) of enclosures/panels may be invalidated by the installation of the EZ-LIGHT(s). The installation of the EZ-LIGHT(s) in a particular enclosure/panel is subject to the evaluation/acceptance of the applicable approval agency.
- The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges.
- Clean with a damp cloth only.
(2) A Qualified Person is a person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
page 2 of 7
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
04-Sep-25
K30L and K50L Intrinsically Safe Indicators
- If the equipment is likely to come into contact with aggressive substances[(3)] , then it is the responsibility of the user to take suitable precautions[(4)] that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised.
- For indicators with multiple colors, only one color is intended to be on at a time.
- When more than one intrinsically safe supply (e.g. two or three barriers) is connected to an LED indicator (input) the combined electrical parameters of the supply must remain intrinsically safe.
## Wiring Diagram
The device is intrinsically safe ONLY when used with certified intrinsically safe switching amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits.
Banner does not manufacture such devices; however, Banner applications engineers can refer you to suppliers of certified devices that will interface with the Banner device.
The user is responsible for proper installation and maintenance of this equipment, and must conform with the certification requirements relating to barriers and to maximum allowable capacitance and inductance of the field wiring. If in doubt about these requirements, Banner applications engineers can refer you to the appropriate authority.
**==> picture [415 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
bu (3) _ Wiring Key 1 = Brown Pinout<br>bk (4) 2 = White 1<br>+ 3 = Blue<br>bn (1) 4 = Black 2<br>Color Key 4<br>wh (2) C1 = Color 1<br>C2 = Color 2 3<br>C3 = Color 3<br>**----- End of picture text -----**<br>
See "Configuration" on page 3 for hazardous area wiring and installation notes.
## Configuration
**==> picture [360 x 305] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control Drawing 1-Color Configuration<br>One Color Configuration<br>Non-Hazardous Location Hazardous Location<br>Non-Explosive Atmospheres Explosive Atmospheres<br>Power<br>I.S. Barrier #1<br>8-30 V DC<br>Ground<br>_<br>Black wire (pin 4)<br>Brown wire (pin 1)<br>N/C<br>White wire (pin 2) K30/K50<br>Blue wire (pin 3)<br>:sll<br>;/<br>N/C Flying Lead or Quick Disconnect Models<br>I.S. Barrier Installation Notes _<br>1. Safety parameters are as follows: 2. Choose approved barriers such that the 3. Install I.S. barriers in 4. Suggested I.S. barriers are as follows<br>Ui/Vmax = 30 V DC following conditions are met with all barriers accordance with manufacturers MTL 7715+ (15 V / 100 Ω)<br>Ii/Imax = 1 A combined instructions and local codes MTL 7715P+ (15 V / 50 Ω)<br>EPL Ga & Ma: Ui / Vmax ≥ Uo / Voc Turck MZB15PX (15 V / 50 Ω)<br>Pi = 3.4 W (Ta = -40 °C to +40 °C) Ii / Imax ≥ Io / Isc<br>Pi = 2.8 W (Ta = -40 °C to +50 °C) Pi / Pmax ≥ Po<br>Ci = 0 Co / Ca ≥ Ci + Ccable IIC IIB IIA<br>Li = 0 Lo /La ≥ Li + Lcable Ccable 66 nF 0.56 µF 1.82 µF<br>EPL Da: —— Lcable 35 µH 140 µH 280 µF<br>Pi = 2.7 W (Ta = -40 °C to +40 °C)<br>Pi = 2.2 W (Ta = -40 °C to +50 °C)<br>Ci = 0<br>Li = 0<br>**----- End of picture text -----**<br>
(3) Aggressive substances—for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials.
(4) Suitable precaution—for example, regular checks as part of routine inspections or establishing from the materials data sheet that it is resistant to specific chemicals.
04-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 3 of 7
K30L and K50L Intrinsically Safe Indicators
## _Control Drawing 2-Color Configuration_ **Two Color Configuration**
**==> picture [333 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
Non-Hazardous Location Hazardous Location<br>Non-Explosive Atmospheres Explosive Atmospheres<br>Power<br>I.S. Barrier #1<br>8-30 V DC<br>Ground<br>Black wire (pin 4)<br>Brown wire (pin 1)<br>I.S. Barrier #2<br>White wire (pin 2) K30/K50<br>Blue wire (pin 3)<br>N/C Flying Lead or Quick Disconnect Models<br>**----- End of picture text -----**<br>
**==> picture [356 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
I.S. Barrier Installation Notes _<br>1. Safety Parameters are as follows: 2. Choose approved barriers such that the 3. Install I.S. barriers in 4. Suggested I.S. barriers are as follows<br>Ui / Vmax = 30 V DC following conditions are met with all barriers accordance with manufacturers MTL 7715+ (15 V / 100 Ω)<br>Ii / Imax = 1 A combined instructions and local codes MTL 7715P+ (15 V / 50 Ω)<br>EPL Ga & Ma: Ui / Vmax ≥ Uo / Voc Turck MZB15PX (15 V / 50 Ω)<br>Pi = 3.4 W (Ta = -40 °C to +40 °C) Ii / Imax ≥ Io / Isc<br>Pi = 2.8 W (Ta = -40 °C to +50 °C) Pi / Pmax ≥ Po<br>Ci = 0 Co / Ca ≥ Ci + Ccable IIC IIB IIA<br>Li = 0 Lo /La ≥ Li + Lcable Ccable 66 nF 0.56 µF 1.82 µF<br>EPL Da: Lcable 35 µH 140 µH 280 µH<br>Pi = 2.7W (Ta = -40 °C to +40 °C)<br>Pi = 2.2W (Ta = -40 °C to +50 °C)<br>Ci = 0<br>Li = 0<br>**----- End of picture text -----**<br>
_Control Drawing 3-Color Configuration_
## **Three Color Configuration**
**==> picture [329 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
Non-Hazardous Location Hazardous Location<br>Non-Explosive Atmospheres Explosive Atmospheres<br>Power<br>I.S. Barrier #1<br>8-30 V DC<br>Ground<br>Black wire (pin 4)<br>I.S. Barrier #2 Brown wire (pin 1)<br>K30/K50<br>White wire (pin 2)<br>Blue wire (pin 3)<br>I.S. Barrier #3 Flying Lead or Quick Disconnect Models<br>**----- End of picture text -----**<br>
**==> picture [75 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
I.S. Barrier Installation Notes<br>**----- End of picture text -----**<br>
**==> picture [348 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
_<br>1. Safety Parameters are as follows: 2. Choose approved barriers such that the 3. Install I.S. barriers in 4. Suggested I.S. barriers are as follows<br>Ui / Vmax = 30 V DC following conditions are met with all barriers accordance with manufacturers MTL 7715+ (15 V / 100 Ω)<br>Ii / Imax = 1 A combined instructions and local codes MTL 7715P+ (15 V / 50 Ω)<br>EPL Ga & Ma: Ui / Vmax ≥ Uo / Voc Turck MZB15PX (15 V / 50 Ω)<br>Pi = 3.4 W (Ta = -40 °C to +40 °C) Ii / Imax ≥ Io / Isc<br>Pi = 2.8 W (Ta = -40 °C to +50 °C) Pi / Pmax ≥ Po<br>Ci = 0 Co / Ca ≥ Ci + Ccable IIC IIB IIA<br>Li = 0 Lo /La ≥ Li + Lcable Ccable 66 nF 0.56 µF 1.82 µF<br>EPL Da: Lcable 35 µH 140 µH 280 µH<br>Pi = 2.7 W (Ta = -40 °C to +40 °C)<br>Pi = 2.2 W (Ta = -40 °C to +50 °C)<br>Ci = 0<br>Li = 0<br>**----- End of picture text -----**<br>
## Specifications
Supply Voltage and Current
See Configuration for safety parameters
page 4 of 7
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
04-Sep-25
K30L and K50L Intrinsically Safe Indicators
## Indicators
Entire translucent diffuser or dome provides indication. LEDs are independently selected: Green, Red, or Amber; 2 or 3 colors, depending on model. For other colors/combinations, contact Banner Engineering for availability.
## Environmental Rating
IP67/IP69K per DIN 40050-9
Approvals
CSA-c/us
Gas and Vapors: Class I Zone 0 AEx/Ex ia IIC T4 Ga / Class I Div 1 Groups ABCD
Dust: Zone 20 AEx/Ex ia IIIC T130°C Da / Class II Div 1 Groups EFG / Class III Div 1
CSA14CA2679646X
ATEX/IECEx/UKCA
Gas and Vapors: II 1 G Ex ia IIC T4 Ga (Group IIC Zone 0) Dust: II 1 D Ex ia IIIC T200 130°C Da (Group IIIC Zone 20) Mines: I M1 Ex ia I Ma (Methane)
Sira 13ATEX2058X IECEx SIR 13.0020X
CSAE 21UKEX2681X
ATEX/UKCA: EN IEC 60079-0:2018 & EN 60079-11:2012
IECEx: IEC 60079-0:2017 Ed.7 & IEC 60079-11:2011 Ed.6
Construction
Base: polycarbonate
Translucent dome: polycarbonate
## Operating Conditions
## EPL Ga & Ma:
- Pi = 2.8W: Ta = –40 °C to +50 °C (–40 °F to +122 °F)
- • Pi = 3.4W: Ta = –40 °C to +40 °C (–40 °F to +104 °F)
- EPL Da:
- Pi = 2.2W: Ta = –40 °C to +50 °C (–40 °F to +122 °F)
- • Pi = 2.7W: Ta = –40 °C to +40 °C (–40 °F to +104 °F)
- See "Configuration" on page 3
Certifications
**==> picture [222 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
Banner Engineering<br>BV Park Lane |<br>Culliganlaan 2F bus 3 |<br>2809 1831 Diegem,<br>BELGIUM<br>Turck Banner<br>LTD Blenheim House |<br>Blenheim Court |<br>1725 Wickford, Essex SS11<br>8YT | Great Britain<br>**----- End of picture text -----**<br>
IEC IECEx SIR 13.0020X ATEX Sira 13ATEX2058X CSAE 21UKEX2681X CSA CoC 2679646
## Connections
Maximum cable length 29 m per parameters list in "Configuration" on page 3.
Connecting 4-pin M12 QD Cordsets (see "Cordsets" on page 6): Female single-ended Multiconductor cable (at minimum): UL Style 2517, 24 AWG wire, rated ≥ 80 °C; M12 quick disconnect connector: per IEC 61076-2-101, must have threaded M12 × 1 retaining nut.
K30: 2 m (6.5 ft) PVC integral cable, or 150 mm (5.9 in) PVC cable with 4-pin M12 quick disconnect connector
K50: 4-pin M12 integral quick disconnect connector, 2 m (6.5 ft) PVC integral cable, or 150 mm (5.9 in) PVC cable with 4- pin M12 quick disconnect connector
**==> picture [63 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
K30L Product Label<br>**----- End of picture text -----**<br>
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
K50L Product Label<br>**----- End of picture text -----**<br>
04-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 5 of 7
K30L and K50L Intrinsically Safe Indicators
## Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change.
**==> picture [66 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
K30L Cabled Models<br>**----- End of picture text -----**<br>
**==> picture [274 x 175] intentionally omitted <==**
**==> picture [500 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
K50L Quick Disconnect Models K50L Cabled Models<br>50.0 mm<br>(1.97")<br> 38 mm (1.50")<br>M30 x 1.5<br>(mounting nut<br>included)<br>Max. Torque 4.5 Nm<br>(40 in-lbf)<br>20 mm (0.79")<br>Internal Threads<br>½ - 14 NPT 11 mm (0.43")<br>Max. Torque 2.25 Nm<br>(20 in-lbf)<br>**----- End of picture text -----**<br>
## Accessories
## Cordsets
**==> picture [500 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
4-Pin Single-Ended M12 Female Cordsets<br>Model Length Style Dimensions Pinout (Female)<br>MQDC-406 2 m (6.56 ft) 44 Typ.<br>MQDC-415 5 m (16.4 ft)<br>1 = Brown<br>MQDC-430 9 m (29.5 ft) 2 2 = White<br>M12 x 1 1 3 = Blue<br>4 = Black<br>Straight ø 14.5 3 5 = Not used<br>Ø5.2 mm 4 5<br>MQDC-450 15 m (49.2 ft)<br>7 mm<br>58 mm<br>Continued on page 7<br>**----- End of picture text -----**<br>
page 6 of 7
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
04-Sep-25
K30L and K50L Intrinsically Safe Indicators
**==> picture [500 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
Continued from page 6<br>4-Pin Single-Ended M12 Female Cordsets<br>Model Length Style Dimensions Pinout (Female)<br>MQDC-406RA 2 m (6.56 ft) 32 Typ.<br>[1.26"]<br>MQDC-415RA 5 m (16.4 ft)<br>MQDC-430RA 9 m (29.5 ft)<br>30 Typ. 2<br>[1.18"] 3<br>1<br>Right-Angle 4<br>M12 x 1<br>ø 14.5 [0.57"]<br>MQDC-450RA 15 m (49.2 ft)<br>Ø5.2 mm<br>7 mm<br>58 mm<br>**----- End of picture text -----**<br>
## Repairs and Translations
Obtain assistance with product repairs by contacting your local Banner Engineering Corp distributor or by calling Banner directly at (763) 544-3164. Access literature translated into your native language on the Banner website at www.bannerengineering.com or contact Banner directly at (763) 544-3164.
Para reparaciones de productos, por favor contacte a su distribuidor local de Banner Engineering o llame a Banner directamente al 00 1 (763) 544-3164. Vea la literatura traducida en su idioma en el sitio web Banner en www.bannerengineering.com o comuníquese con Banner directamente al 00 1 (763) 544-3164.
Pour vous aider lors de la réparation de produits, contactez votre distributeur Banner local our appelez directement Banner au (763) 544-3164. La documentation traduite dans votre langue est disponible sur le site internet de Banner www.bannerengineering.com ou contactez directement Banner au (763) 544-3164.
请联系当地的 Banner Engineering Corp 经销商或直接致电 Banner +1 (763) 544-3164,以获得产品维修帮助。请访问邦纳网站 www.bannerengineering.com 或直接拨打 +1 (763) 544-3164 联系邦纳,获取翻译成您母语的资料。
제품 수리에 대한 지원은 지역 Banner Engineering Corp 대리점에 문의하거나 Banner에 직접 (763) 544-3164로 문의하실 수 있습니다. 사용자의 모국어로 번역된 자료는 Banner 웹사이트 www.bannerengineering.com에서 액세스하거나 Banner에 직접 (763) 544-3164로 문의하실 수 있습니 다.
## Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
04-Sep-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 7 of 7
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →