K100PBLNZGBR
VISUAL SIGNAL INDICATOR UNITS
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 503.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## Features
High Daylight Visibility, Programmable Multicolor Indicator with Optional Audible Alarm for Indoor or Outdoor Use
- Highly visible indicator provides bright, even light in direct sunlight
- • Ex/HazLoc approvals for potentially explosive environment applications. ATEX/IECEx and U.S./Canadian Zone approvals on non-audible models only
- • Three colors in one device • Programmable using Banner's Pro Editor software and Pro Converter Cable • 36 mm threaded polycarbonate base • Rugged IP69K per ISO 20653, UL Type 4X housing • PNP or NPN operation depending on wiring • Rugged UV-stabilized polycarbonate base and dome • 12 V DC to 48 V DC operating voltage • 100 V AC to 240 V AC operating voltage • IK10 Impact rating for maximum protection in demanding applications
## Models
**==> picture [491 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Family|Style|Type|Classification|Voltage|Color 1|Color 2|Color 3|Audible|Connector|[(1)]|
|G = Green|G = Green|G = Green|Blank = Non-audible|Blank = 2 m (6.5 ft) integral cable|[(2)]|
|Y = Yellow|Y = Yellow|Y = Yellow|
|BL =|N = Hazardous|
|K100|P = Pro|Z = AC|R = Red|R = Red|R = Red|
|Beacon|Area|A = Audible|Q = Integral 5-pin M12 male quick-|
|B = Blue|B = Blue|B = Blue|disconnect (QD) connector|[(3)]|
|W = White|W = White|W = White|
**----- End of picture text -----**<br>
Audible and non-audible K100 Pro Beacon models are approved for (both 2 m integral cable and QD models):
- Class I Div. 2, Groups ABCD
- Class II Div. 2, Groups FG
- • Class III Div. 1 & Div. 2
Additionally, non-audible K100 Pro Beacon models with 2 m integral cable are ATEX/IECEx and U.S./Canadian Zone[(2)] approved for:
- x II 3 G Ex ec IIC T4 Gc
- II 3 D Ex tc IIIC T85°C Dc
- Class I Zone 2, AEx ec IIC T4 Gc
- • Class I Zone 2, Ex ec IIC T4 Gc • Zone 22, AEx tc IIIB T85°C Dc • Zone 22, Ex tc IIIB T85°C Dc
## Installation Instructions
## Ex/HazLoc Applications
## WARNING:
- Explosive Atmospheres/Hazardous Locations
- It is the user's responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relating to the installation and use of this device in any particular application are satisfied. This device must be installed by a Qualified Person[(4)] , in accordance with this document and applicable regulations.
- (1) Models with a quick-disconnect connector require a mating cordset.
(2) For American/Canadian Zone Certification, must be enclosed with a protected conduit or suitable enclosure as detailed in the specific conditions of use.
> (3) Must be enclosed with a protected conduit or a suitable enclosure.
- (4) A Qualified Person is a person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
Original Instructions 18-Feb-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
p/n: 225025 Rev. D
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## WARNING:
- Explosion Hazard
- Do not disconnect equipment unless the power has been switched off or the area is known to be nonhazardous.
## WARNING:
- Electrostatic Discharge (ESD) Specific Conditions for Safe Use
- Parts of the enclosure are non-conducting and can generate an ignition-capable level of ESD.
- To reduce the risk of ignition due to electrostatic discharge, avoid contact with the equipment while an explosive atmosphere is present.
- Clean the equipment with only a damp cloth.
## Specific Conditions for Use and General Notes
- See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations, electrical connections and certifications.
- In addition to the warning above concerning user responsibility, the installation must comply with the following:
- All installations must comply with all manufacturer's instructions.
- All applicable wiring methods in accordance with the relevant local regulations and the authority having jurisdiction.
- ◦ U.S. Installations: The relevant requirements of the National Electric Code® (ANSI/NFPA-70 NEC®).
- Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1).
- ◦ ATEX / IECEx Installations: The relevant requirements of EN IEC 60079-14 and applicable National regulations.
- Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with non-factory components may adversely affect the safe use of the system.
- The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges.
- Clean with a damp cloth only.
- If the equipment is likely to come into contact with aggressive substances[(5)] , then it is the responsibility of the user to take suitable precautions[(6)] that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised.
- • The ingress protection (IP rating) of enclosures/panels may be invalidated by the installation of the beacon. The installation of the beacon in a particular enclosure/panel is subject to the evaluation/acceptance of the authority having jurisdiction.
- Models with integral quick-disconnect (QD) connectors: Use recommended Banner cordsets (see "Cordsets" on page 7), or suitable quick-disconnect cordsets with threaded retaining nut (see"Specifications" on page 4). The cordset must be securely fastened using the quick-disconnect retaining nut to prevent disconnection. Maximum connector torque: 6 ft-lbs.
- Must be installed such that the connector is protected from impact and unauthorized disconnection. The method of protection can include conduit (e.g. pole, pendent), enclosed raceway, a listed enclosure suitable for the intended use, and/ or by inaccessible location that excludes possible impact damage.
- ATEX / IECEx Installations; additional specific conditions of use
- The Beacon shall only be installed in areas with low risk of mechanical impact.
- Transient protection shall be provided at a level not exceeding 140% of the peak rated voltage at the supply terminals of the Beacon.
- For Zone 2: When the equipment is mounted to an external enclosure, the external enclosure shall be rated ATEX/IECEx Zone 2 IP54 minimum, in accordance with IEC/EN 60079-0. To maintain the IP64 rating for the overall assembly of beacon and external enclosure, the external enclosure and any fittings used must be rated IP64 minimum.
- For Zone 22: When the equipment is mounted to an external enclosure, the external enclosure shall be rated ATEX/IECEx Zone 22 IP64 minimum, in accordance with IEC/EN 60079-0 and IEC/EN 60079-31.
- U.S. / Canadian Zone Installations; additional specific conditions of use ◦ Only non-audible K100 Pro Beacon models with 2 m integral cable. ◦ The Beacon shall only be installed in areas with low risk of mechanical impact.
- Transient protection shall be provided at a level not exceeding 140% of the peak rated voltage at the supply terminals of the Beacon.
- The beacons must be mounted to a conduit/standoff pipe or on an external enclosure. The K100 beacons must be installed on the conduit/standoff pipe or external enclosure in a way that ensures all field wiring is fully contained within the conduit/ standoff pipe or external enclosure.
- For Zone 2: When the beacon is mounted to an external enclosure, the external enclosure shall be rated Zone 2 IP54 minimum, in accordance with UL/CSA 60079-0. To maintain the IP64 rating for the overall assembly of beacon and external enclosure, the external enclosure and any fittings used must be rated IP64 minimum.
- For Zone 22: When the beacon is mounted to an external enclosure, the external enclosure shall be rated Zone 22 IP64 minimum, in accordance with UL/CSA 60079-0 and UL/CSA 60079-31.
> (5) Aggressive substances—for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials.
> (6) Suitable precaution—for example, regular checks as part of routine inspections or establishing from the materials data sheet that is resistant to specific chemicals.
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 2 of 8
18-Feb-25
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## Mechanical Installation
Install in a location free of visual obstructions, protected from impact and/or an inaccessible location that minimizes possible impact damage. The K100 Beacon, the cable, and the quick-disconnect connector (if used) must be protected from environmental influences, impact, and unauthorized disconnection (for example, inaccessible location).
The installation of the K100 Beacon must comply with all applicable wiring methods in accordance with the relevant local regulations and the authority having jurisdiction. The K100 Beacon is supplied with a foam washer, an M36 knurl nut, and a 105 mm protective shield.
The K100 has three typical mounting methods:
## Enclosure-Mounted
Use only a listed enclosure suitable for the intended use and appropriately rated for the application and the environment as specified in the Specific Conditions of Use section (above). The K100 Beacon requires a 36 mm hole and the enclosure must extend beyond the K100 housing.
The ingress protection (IP rating) of enclosures may be invalidated by the installation of the beacon.
Proper installation of the foam washer is between the K100 Beacon and the enclosure. The M36 knurl nut is installed on the interior of the enclosure and torqued to a maximum of 5.0 N·m (44 inch-lbf).
## LMB36RA Mounting Bracket
Mount the LMB36RA, or similar L- or flat-plate bracket (customer supplied), in the desired location that complies with the above general mechanical installation requirements.
To maintain ATEX/IECEx and U.S./Canadian Zone ratings, the installation must use the 105 mm protective shield. The protective shield is mounted between the K100 Beacon and the mounting bracket; the M36 knurl nut is installed once the K100 Beacon is in place and torqued to a maximum of 5.0 N·m (44 inch-lbf).
The K100 Beacon cable and the quick-disconnect connector (if used) may be required to be located within 3/4-14 NPT conduit (see below) or race/cable tray as described by relevant local regulations.
## Conduit / Standoff Pipe
Identify the desired mounting location that complies with the above general mechanical installation requirements, and route the conduit as described by relevant local regulations. Depending on the application, conduit sealing methods may be required at the connection of the conduit and the K100 Beacon (that is, the metal-to-plastic junction will not be gas-tight).
To maintain ATEX/IECExand U.S./Canadian Zone ratings, the installation must use the 105 mm protective shield. The protective bracket is mounted on the base of the K100 Beacon using the M36 knurl nut torqued to a maximum of 5.0 N·m (44 inch-lbf). Once the protective bracket is installed, the K100 Beacon assembly can be fitted onto the 3/4-14 NPT conduit/pipe and tightened to a maximum torque of 4.0 N·m (35 inch-lbf).
## Wiring Diagrams
**==> picture [500 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Diagram Key<br>wh (3)<br>Neutral<br>100-240 V AC<br>bn (1)<br>1 Hot<br>1 = Brown<br>bu (2) 2 = Blue<br>2 3 = White<br>4 = Black<br>bk (4)<br>3 5 = Gray<br>gy (5)<br>A<br>**----- End of picture text -----**<br>
## An "X" denotes an active input.
For example: When Input 1 and Input 3 are both active, the indicator will be Color 1 Flashing at 1 Hz. Refer to model number scheme in "Models" on page 1 to determine individual colors.
## Default Configuration
**==> picture [500 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wiring Operating Mode/Function<br>Brown Blue Black Gray Non-Audible Audible<br>(Input 1) (Input 2) (Input 3) (Input 4)<br>X Color 1 Steady Color 1 Steady<br>X Color 2 Steady Color 2 Steady<br>X Color 3 Steady Color 3 Steady<br>Continued on page 4<br>**----- End of picture text -----**<br>
© Banner Engineering Corp. All rights reserved.
page 3 of 8
18-Feb-25
www.bannerengineering.com
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
**==> picture [500 x 213] intentionally omitted <==**
**----- Start of picture text -----**<br>
Continued from page 3<br>Wiring Operating Mode/Function<br>Brown Blue Black Gray Non-Audible Audible<br>(Input 1) (Input 2) (Input 3) (Input 4)<br>X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz<br>X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz<br>X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz<br>X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe<br>X Off Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 1 Steady Color 1 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 2 Steady Color 2 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X Color 3 Steady Color 3 Steady, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High<br>X X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe, Audible Steady, Frequency 2.5 KHz, Volume High<br>**----- End of picture text -----**<br>
## Specifications
## Supply Protection Circuitry
Protected against reverse polarity and transient voltages
## Leakage Current Immunity
400 µA
The use of relay output PLC is recommended since there is no leakage current. Solid state output PLCs often have leakage current above 1 mA and, therefore, turn the light on in the off state. To counteract the leakage current, a shunt resistor must be used. A resistor must be applied from the neutral wire of the device to the hot wire of each channel of the device.
## Indicator Response Time
On Response: 350 ms (maximum)
Off Response: 20 ms (maximum)
## Audible Characteristics
Sound Intensity at 2.5 KHz, at 1 m (typical):
Low volume setting: 93 dB Medium volume setting: 96 dB High volume setting: 101 dB
## Construction
Base, Dome, and Nut: Polycarbonate 105 mm protective shield: Stainless steel
## Operating Conditions
–40 °C to +60 °C (–40 °F to +140 °F)
90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F)
## Connections
2 m (6.5 ft) integral ITC-ER PVC-jacketed cable:
PLTC and ITC-ER (UL 2095) 22 AWG (0.34 mm[2] ), 105°C, 300 V
Jacket & Conductor Insulation: PVC Jacket Diameter: 5.6 mm
Integral 5-pin Dual-key (M12-style) male quick-disconnect connector:
1/2-20UNF
Aluminum Black Anodize
Models with a quick disconnect require a mating cordset. Specific cordset will be determined by installation requirements, at a minimum:
5-pin Dual-key (M12-style) female quick-disconnect cordset (see "Cordsets" on page 7) Dual-key connector must have threaded 1/2-20UNF retaining nut
Multiconductor cable: UL AWM 2517, 24 AWG (0.25 mm[2] ) wire, rated ≥ 80 °C
## Mounting
M36 by 2.0 threaded base, maximum torque 5.0 N·m (44 inch-lbf)
Interior 3/4-14 NPT Thread
Mounting nut included
Adjacent Unit Mounting Separation Distance Minimum: 0 in (mounted with unit flanges touching)
page 4 of 8
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
18-Feb-25
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## Approvals
## NEC and CEC (cULus)
Gas and Vapors: Class I Div 2 Groups ABCD T4 Dust and Fibers/flyings: Class II Div 2 Groups FG T6; Class III Div 1 and Div 2 T6 NOIV(7) E530817-Vol1-Sec1
## ATEX/IECEx
Only non-audible K100 Pro Beacon models with 2 m integral cable
Gas and Vapors: II 3 G Ex ec IIC T4 Gc (Group IIC Zone 2)
Dust: II 3 D Ex tc IIIC T85°C Dc (Group IIIC Zone 22) UL 24 ATEX 3240X IECEx UL 24.0047X
## Supply Voltage and Current
100 V AC to 240 V AC, 50 Hz to 60 Hz
**==> picture [206 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
Maximum Current (mA AC at 60 Hz)<br>Steady On, Flash, or Strobe Rotate Function<br>Function [(7)]<br>Light &<br>Voltage Light Only Light & Audible Light Only Audible<br>100 140 154 96 100<br>230 78 85 62 68<br>**----- End of picture text -----**<br>
## Default Indicator Characteristics
- U.S. and Canadian Zone Certification
Only non-audible K100 Pro Beacon models with 2 m integral cable Must be enclosed with a protected conduit or suitable enclosure as detailed in the specific conditions of use Class I Zone 2, AEx ec IIC T4 Gc Class I Zone 2, Ex ec IIC T4 Gc Zone 22, AEx tc IIIB T85°C Dc Zone 22, Ex tc IIIB T85°C Dc
FOR **Ind. Cont. Eq.For HazLoc** -40°C ≤ Ta ≤ +60°CClass I Division 2 Groups ABCD T4 Banner Engineering, **E530817** USTED Class II Division 2 Groups FG T6Class III Division 1 & Division 2 T6 Minneapolis, MN 55441 USA
|Color|Dominant Wavelength<br>(nm) or Color|Color<br>Coordinates(8)|Color<br>Coordinates(8)|Lumen Output<br>(Typical at 25|Lumen Output<br>(Typical at 25|
|---|---|---|---|---|---|
|Green|Temperature (CCT)<br>528 nm|x<br>0.1603|y<br>0.6973|360|°C)|
|Yellow|589 nm|0.5557|0.4276|525||
|Red|625 nm|0.6999|0.2982|155||
|Blue|475 nm|0.1167|0.1121|165||
|White|5000K|0.332|0.3433|600||
E530817 usa
Maximum Input Power Light Only: 12.33 W Light and Audible: 13.7 W
Internal temperature compensation circuitry: Reduces the Lumen Output to decrease the unit internal operating temperature. The amount of reduction is dependent on the ambient operating temperature, supply voltage, color, and/or audible functions being utilized.
## Required Overcurrent Protection
## Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave)
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.
Impact: IK10 (60068-2-75)
## Environmental Rating
UL Type 4X
IP66, IP69K per ISO 20653. IP64 when mounted on to an enclosure.
## LED Lifetime
Lumen maintenance L70
When operating within specifications, output decreases less than 30% after 42,000 hours
## Certifications
Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM LISTED E530817
Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go
to www.bannerengineering.com.
**==> picture [208 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br>
(7) Flash or Strobe Mode: Peak current, operating at 50% duty cycle or less. (8) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates.
## Photometric Data
Multiply the values shown in the chart by the maximum candela values in the Max. Candela table:
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 5 of 8
18-Feb-25
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## Polar Candela Distribution
**==> picture [148 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
180°<br>1.2 170°160°150°<br>1 140°<br>0.8 130°<br>0.6 120°<br>0.4 110°<br>0.2 100°<br>0 90°<br>0.2 80°<br>0.4 70°<br>0.6 60°<br>0.8 50°<br>1 40°<br>1.2 Vertical Angle: 0° 10° 20° 30°<br>0° Vertical 90° Horizontal<br>**----- End of picture text -----**<br>
## Base Candela
**==> picture [500 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Green 46<br>Yellow 67<br>Red 20<br>Blue 21<br>White 76<br>**----- End of picture text -----**<br>
## Candela Viewing Angle Example – Red
**==> picture [500 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
Angle Factor Base [(9)] Candela<br>120 (top view) 0.7 20 14<br>90 (side view) 1 20 20<br>60 (bottom view) 0.7 20 14<br>**----- End of picture text -----**<br>
## Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change.
**==> picture [500 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
Standard Models Audible Models<br>Ø 92.8 Ø 92.8<br>[3.65] [3.65]<br>80.9 81.0<br>[3.18] [3.19]<br>134.7 134.8<br>[5.3] [5.31]<br>25.5<br>25.5 M36 x 2.0 [1.01]<br>M36 x 2.0 [1.01]<br>Interior<br>Interior 3/4 - 14 NPT<br>3/4 - 14 NPT<br>13.0 1/2 - 20 13.0<br>1/2 - 20 [0.51] [0.51]<br>Ø 118.5<br>Ø 118.5 [4.67]<br>[4.67]<br>**----- End of picture text -----**<br>
(9) Red shown. See Base Candela table.
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 6 of 8
18-Feb-25
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## Accessories
## Cordsets
All measurements are listed in millimeters, unless noted otherwise. The measurements provided are subject to change.
MQAC2-5xx specifications:
- 1/2-20UNF female retaining nut
- • AWM (UL 2517) 22 AWG, 105 °C, 300 V • Jacket & Conductor Insulation: PVC • Jacket Diameter: 5.6 mm
**==> picture [500 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
5-Pin Single-Ended 1/2-in Dual Key Female Cordsets<br>Model Length Style Dimensions Pinout (Female)<br>MQAC2-506 2 m (6.56 ft) 3 4<br>42 Typ.<br>MQAC2-515 5 m (16.4 ft)<br>2<br>1 5<br>Straight<br>1/2-20 UNF-2B 1 = Brown<br>MQAC2-530 9.14 m (30 ft) 2 = Blue<br>ø 14.5 3 = White<br>4 = Black<br>5 = Gray<br>**----- End of picture text -----**<br>
## Brackets
**==> picture [500 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
65 70<br>50.8<br>LMB36RA • Indicator light right-angle mounting 4 X Ø6.5 25.4<br>• 36 mm mounting hole Ø36.5<br>• Stainless steel 62.5<br>**----- End of picture text -----**<br>
## Elevated Mount System
**==> picture [500 x 222] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model<br>Black Anodized Black Anodized Aluminum Clear Anodized Aluminum Features Components<br>Aluminum<br>½ in. NPT ½ in. NPT<br>¾ in. NPT<br>SOP-E34-150A 150 mm SOP-E12-150A 150 mm (6 SOP-E12-150AC 150 mm<br>(6 in) long in) long (6 in) long<br>• Elevated-use stand-off pipe<br>SOP-E34-300A 300 mm SOP-E12-300A 300 mm (12 SOP-E12-300AC 300 mm • Black anodized aluminum or clear<br>(12 in) long in) long (12 in) long anodized aluminum surface<br>• Threaded at both ends<br>SOP-E34-600A 600 mm SOP-E12-600A 600 mm (24 — • Compatible with most industrial<br>(24 in) long in) long environments<br>SOP-E34-900A 900 mm SOP-E12-900A 900 mm (36 SOP-E12-900AC 900 mm<br>(36 in) long in) long (36 in) long<br>Pipe Mounting Flange<br>Model Description Construction<br>1/2-14 54<br>• Elevated-use stand-off pipes (½ in, NPSM/ NPSM 4x ø5.5<br>SA-F12 • DN15)M5 mounting hardware and nitrile gasket included Die-cast zinc base with black paint 10 ø70ø28<br>**----- End of picture text -----**<br>
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
page 7 of 8
18-Feb-25
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet
## Shields
105 mm Protective Shield
- Impact protection
- Stainless steel
- • See "Specific Conditions for Use and General Notes" on page 2 and "Mechanical Installation" on page 3
**==> picture [67 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø105<br>Ø35.8<br>**----- End of picture text -----**<br>
## Repairs and Translations
Obtain assistance with product repairs by contacting your local Banner Engineering Corp distributor or by calling Banner directly at (763) 544-3164. Access literature translated into your native language on the Banner website at www.bannerengineering.com or contact Banner directly at (763) 544-3164.
Para reparaciones de productos, por favor contacte a su distribuidor local de Banner Engineering o llame a Banner directamente al 00 1 (763) 544-3164. Vea la literatura traducida en su idioma en el sitio web Banner en www.bannerengineering.com o comuníquese con Banner directamente al 00 1 (763) 544-3164.
Pour vous aider lors de la réparation de produits, contactez votre distributeur Banner local our appelez directement Banner au (763) 544-3164. La documentation traduite dans votre langue est disponible sur le site internet de Banner www.bannerengineering.com ou contactez directement Banner au (763) 544-3164.
请联系当地的 Banner Engineering Corp 经销商或直接致电 Banner +1 (763) 544-3164,以获得产品维修帮助。请访问邦纳网站 www.bannerengineering.com 或直接拨打 +1 (763) 544-3164 联系邦纳,获取翻译成您母语的资料。
제품 수리에 대한 지원은 지역 Banner Engineering Corp 대리점에 문의하거나 Banner에 직접 (763) 544-3164로 문의하실 수 있습니다. 사용자의 모국어로 번역된 자료는 Banner 웹사이트 www.bannerengineering.com에서 액세스하거나 Banner에 직접 (763) 544-3164로 문의하실 수 있습니 다.
## Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
## Contact Us
Banner Engineering Corp. headquarters is located at: 9714 Tenth Avenue North | Plymouth, MN 55441, USA | Phone: + 1 888 373 6767
For worldwide locations and local representatives, visit www.bannerengineering.com.
page 8 of 8
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com
18-Feb-25
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →