Image not available
Illustrative purposes only
IULN111-1REC4-61-15.0-E
MAGNETIC HYDRAULIC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-AIRPAX / PARTNER STOCK
- Product type: Magnetic Hydraulic Circuit Breakers
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 413.55 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **IAL/CEL/LEL Series** Magnetic Circuit Protectors |_Introduction_|**•** **_147_**| |---|---| |_Poles_|**•** **_148_**| |_Handles_|**•** **_150_**| |_Configurations_|**•** **_154_**| |_Operating Characteristics_|**•** **_157_**| |_Delay Curves_|**•** **_159_**| |_Specifications_|**•** **_163_**| |_Decision Tables_|**•** **_165_**| ## AIRPAX: **IAL/CEL/LEL Series** | Hydraulic Magnetic Circuit Protectors ## **INTRODUCTION** IAL/IUL/IEL/LEL magnetic circuit protectors provide low-cost power switching, reliable circuit protection and accurate circuit control for equipment in the international marketplace. the LEL models are UL listed under the conditions of UL 489. Both are CSA certified and CCC Approved. The IEL is CSA certified as a supplementary protector per CSA C22.2–No. 235. IAL models are for those applications where the unit’s inherent attributes are desired, but compliance with the various standards is not required. The CEL model has achieved two new enhancements, including a single pole, 125 amp rating with TÜV approval, and a parallel 4-pole version with 400 amp rating. IUL models have been tested and approved in accordance with UL 1077 requirements for UL recognition. IEL/LEL models are VDE approved to VDE 0660, part 101. They meet IEC spacing requirements, mandatory for equipment which must comply with IEC specifications 601 and 950, and VDE specifications 0804 and 0805. In addition, the IEL models are UL recognized to UL 1077 as supplementary protectors and Airpax™ IAL/CEL/LEL circuit protectors are available in a wide variety of configurations, including series, series with auxiliary switch, shunt and relay with choice of delays and ratings in DC and/or 50/60Hz or 400Hz versions. Single or multi-pole versions are available with a variety of pole arrangements to meet your specifications. Please see the appropriate product specification table for ratings and limitations. **147** _IAL Series - Introduction_ http://airpax.sensata.com ## **SINGLE POLE, STANDARD STUD TERMINAL** **==> picture [181 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> (SEE TABLE)<br>.281<br>[7.14] .140<br>(SEE TABLE) [3.56]<br>ON<br>1.940<br>[49.28]<br>.142<br>[3.61] OFF<br>1.859 .690<br>[47.22] [17.53]<br>**----- End of picture text -----**<br> **==> picture [263 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> STUD TERMINAL TYPES<br>Screw Stud Thread Dimension “A” Dimension “B”<br>.510 ± .045 .652 ± .035<br>M6<br>[12.95 ± 1.14] [16.56 ± 0.89]<br>.545 ± .045 .687 ± .035<br>1/4 -20<br>[13.84 ± 1.14] [17.45 ± 0.89]<br>.510 ± .045 .652 ± .035<br>M5<br>[12.95 ± 1.14] [16.56 ± 0.89]<br>.545 ± .045 .687 ± .035<br>10-32<br>[13.84 ± 1.14] [17.45 ± 0.89]<br>**----- End of picture text -----**<br> ## Single Pole ## Mounting Detail **==> picture [506 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> 2X 6-32 THREAD .755<br>.140 [3.56] DEEP [19.18]<br>M3 ISO THD. OPTIONAL<br>.402 .220<br>[10.21] [5.59]<br>1.448 Panel Mounting Detail<br>[36.78] 2.060 Tolerance ±.005 [.13] unless noted.<br>[52.32]<br>1.438<br>[36.53] 2.060<br>[52.32]<br>2.490 .432 2X Ø .156<br>[63.24] [10.98] [3.96]<br>.750<br>[19.05]<br>**----- End of picture text -----**<br> **==> picture [280 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> Screw Terminal Clip Terminal<br>.281 Ø .250 MAX.<br>.281 [7.13] [6.35]<br>[7.13]<br>1.940 1.940<br>[49.28] [49.28]<br>.142 .375<br>[3.61] [9.53]<br>.392<br>[9.96]<br>.592<br>[15.04]<br>**----- End of picture text -----**<br> ## Bullet Terminal **==> picture [19 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> .967<br>[24.57]<br>**----- End of picture text -----**<br> **==> picture [67 x 89] intentionally omitted <==** Notes: - Tolerance ± .015 [.39] unless noted. Bullet terminal receptacle should be .312 ± .001 diameter hole not less than .250 depth. Contact Sensata for other bullet sizes. Dimensions in brackets [ ] are millimeters. - A Terminal protrusion dimensions are referenced from back of mounting panel. - B Each screw terminal is supplied with a 10-32x.312 [7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher. Note: Each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut. - C Stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or M5 hex nut (<=70A) (<=50A for LEL),1/4-20 or M6 hex nut (>70A)(>50A for LEL). _IAL Series - Poles_ **148** **==> picture [612 x 60] intentionally omitted <==** ## **MULTI-POLE CIRCUIT PROTECTORS** Multi-pole units are combined in an assembly with the trip mechanisms internally coupled. A fault in any protected circuit opens all poles simultaneously. Applications include use in polyphase circuits, single-phase three-wire systems, or in two or more related but electrically isolated circuits. A mix of delays, ratings and configurations are offered. The auxiliary switch is offered with either gold or silver contacts and is available when a series construction pole is specified. ## **Two Pole Units** An assembly consisting of two single pole units, having their trip mechanisms internally coupled, is available with either a single toggle handle or with a handle per pole. Please see decision one of the part number decision tables. Individual poles may vary in ratings, delays and internal configurations. If the poles are of series construction, an auxiliary switch may be included in either or both poles, allowing you to mix SELV and hazardous voltages. **==> picture [181 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> Two Pole<br>(SEE TABLE)<br>.281<br>[7.14] .140<br>(SEE TABLE) [3.56]<br>ON<br>1.940<br>[49.28]<br>.142<br>[3.61] OFF<br>1.859 .690<br>[47.22] [17.53]<br>**----- End of picture text -----**<br> **==> picture [249 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> IELH11 IEL11<br>4X 6-32 THREAD<br>.140 [3.56] DEEP<br>.402 .220 M3 ISO THD. OPTIONAL<br>[10.21] [5.59]<br>1.438<br>[36.53]<br>2.060<br>[52.32]<br>1.515 1.515<br>2.490 [38.48] [38.48]<br>[63.24] MAX. MAX.<br>Note:<br>Tolerance ± .015 [.38] unless noted.<br>Dimensions in brackets [ ] are millimeters.<br>**----- End of picture text -----**<br> **==> picture [188 x 74] intentionally omitted <==** **----- Start of picture text -----**<br> M6 .510 .652<br>1/4 - 20 .545 .687<br>M5 .510 .652<br>10 - 32 .545 .687<br>Screw stud Dim. “A” Dim. “B”<br>thread (± .045) (± .035)<br>**----- End of picture text -----**<br> Note: Each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut. **==> picture [316 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> Two Pole* Two Pole*<br>1.530<br>4X Ø .15 6 [38.86]<br>[3.96]<br>1.448<br>[36.78] 2.060<br>[52.32]<br>[10.97].432 [19.05].750 [19.05].750 Panel Mounting Detail Tolerance ±.005 [.13] unless noted.<br>**----- End of picture text -----**<br> Note: A Terminal protrusion dimensions are referenced from back of mounting panel. - B Each screw terminal is supplied with a 10-32x.312 [7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher. - C Stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or M5 hex nut (<=70A), 1/4 -20 or M6 hex nut (>70A). _IAL Series - Poles_ http://airpax.sensata.com **149** ## **Three Pole and Four Pole Units** The three pole structure consists of three single pole units assembled with an internal mechanical interlock which actuates all units simultaneously. The units are available with either a single toggle handle or with a handle per pole. Units with four pole construction operate with a minimum of two center toggle handles or with a handle per pole. Please see decision one of the part number decision tables. Mixing of delays, ratings and configurations is available in each individual pole. The auxiliary switch is offered in any series trip pole. ## **BX - FLAT ROCKER HANDLE** The innovative new design of our IAL/CEL/LEL BX Style circuit protectors features a flat rocker that will satisfy your aesthetic needs while guarding against accidental actuation, providing the highest degree of circuit protection and quality. Only Airpax offers this new standard in user interface. Available on a variety of versions with a full range of agency approvals, the IEL BX style circuit protectors meet or exceed all current performance specifications, including interrupting capacities up to 50,000 amperes. Breaker poles are numbered consecutively when viewed from the terminal side, with the ON position up, starting with pole #1 on the left side and proceeding to the right. **==> picture [526 x 427] intentionally omitted <==** **----- Start of picture text -----**<br> 2.173 MAX. .387 REF.<br>Three Pole Mounting Detail* [55.19] [9.84]<br>.125<br>IEL111 1.859 [3.17]<br>[47.22]<br>.768<br>[19.49]<br>1.395<br>[35.43]<br>2.490 MAX.<br>[63.25]<br>.750<br>2.265 [19.05] .750<br>[57.53] [19.05]<br>MAX.<br>1.239<br>Three Pole Mounting Detail* [31.47]<br>IELH111<br>.314<br>[7.98]<br>6-32 THD. MOUNTING<br>M3 ISO THD. OPTIONAL<br>.750 MAX.<br>[19.05]<br>.750<br>2.265 [19.05] .750<br>[57.53]MAX. 2.280 [19.05] ACTUATIO N<br>[57.91] POSITION "OFF"HANDLE ACCESS(SEE NOTE) POSITION "ON"HANDLE<br>1.660 (SIXTH DECISION, G)WITH GUARD (SIXTH DECISION, G)WITH GUARD<br>Four Pole Mounting Detail* [42.16]<br>IEL1111<br>1.530<br>[38.86] OPTIONAL<br>GUARD<br>(SEE DETAIL ìCî) SINGLE POLE<br>.750<br>[19.05] HANDLE HANDLE<br>POSITION "OFF" POSITION "ON"<br>GUARD WITH NO ACTUATE GUARD WITH NO ACTUATE<br>OFF FEATURE OFF FEATURE<br>3.015 (SIXTH DECISION, X) (SIXTH DECISION, X)<br>[76.58] .750 .750<br>MAX. [19.05] [19.05].750 [19.05] [42.16]1.660 [32.00]1.260<br>Four Pole Mounting Detail*<br>IELH1111 2X ÿ.156 .200<br>3.030 [3.96] [5.08]<br>[76.96]<br>HANDLE HANDLE<br>Panel Mounting Detail POSITION "OFF" POSITION "ON"<br>Mounting Detail Tolerance: WITHOUT GUARD WITHOUT GUARD<br> ±.005 [.13] unless noted DETAIL "A"<br>NOTE: ACCESS IS LIMITED TO A DEVICE SMALLER THAN THE<br> UNDERWRITERS LABORATORY "ARTICULATED PROBE"<br> DEFINED IN UL-489 FIG. 11.1.7.2.1.<br>I<br>I<br>I<br>ON<br>ON<br>ON<br>O<br>PUSHTO PUSHTO<br>RESET RESET<br>O O<br>OFF O<br>ONI<br>OFF OFF<br>ONI<br>ONI<br>OFF<br>**----- End of picture text -----**<br> **==> picture [197 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> Four Pole Mounting Detail*<br>IELH1111<br>3.030<br>[76.96]<br>[76.58]3.015 .750 .750<br>MAX. [19.05] [19.05]<br>.750<br>[19.05]<br>**----- End of picture text -----**<br> Note: Panel Mounting Detail Tolerance ±.005 [.13] unless noted. Tolerance ± .015 [.39] unless noted. Dimensions in brackets [ ] are millimeters. *See Single Pole Mounting Detail for Hole Sizes and Locations. _IAL Series - Handles_ **150** **==> picture [612 x 60] intentionally omitted <==** ## **LELHP/CELHP CIRCUIT PROTECTORS** The Airpax™ LELHP/CELHP high current magnetic circuit protector compliments our entire series of LEL circuit protectors. Its unique, parallel current sensing design provides precise current overload protection and reliability in the compact size of a two pole LEL. The unit is ideal for high power DC applications such as drive motor systems and telecommunication power systems. LEL is available in series and series with auxiliary switch configurations with a choice of delays for DC ratings of 125, 150, 175 and 200 amperes. The CEL has been enhanced to include these same ratings plus a 4-pole, parallel 400 amp rating for UL489A. The LELHP is UL listed under the conditions of UL489 and CSA certified. The CELHP is UL listed under the conditions of UL489A. Mid-trip handle indication, voltage trip and remote operator options complete the LELHP/CELHP circuit breaker series. Please see the individual product tables for approved ratings. **==> picture [549 x 496] intentionally omitted <==** **----- Start of picture text -----**<br> Two Pole<br>1.515 MAX<br>.687 [38.48]<br>[17.45] .740 2X 6-32 THREAD<br>[7.14].281 [13.84].545 [3.56].140 (Note E)[18.80] [10.21].402 .140 [3.56] DEEPM3 ISO THD OPTIONAL [5.59].220<br>.640 ON<br>1.047 [16.26] 2.490<br>[26.59] [63.25]<br>1.438 2.060<br>1.940 [36.53] [52.32]<br>[49.28]<br>1.282 OFF<br>[32.56]<br>1/4-20 STU D 1.859 .690 .750<br>(M6 x 1.0 STUD [47.22] [17.53] [19.05]<br>OPTION)<br>Three Pole (Note D)<br>.740<br>Series Parallel Series Parallel with optional (Note E)[18.80]<br>.740 .220<br>1REC4 Auxiliary switch [18.80] [5.59]<br>(Note E)<br>.402<br>[10.21]<br>C<br>NO<br>BREAKER INNC [36.53]1.438 OFF OFF OFF [52.32]2.060<br>OFF POSITION 2.490<br>[63.25]<br>-REC4 175/200 Parallel Pole<br>.110 2.265 MAX.<br>[57.53]<br>[2.79] 6X 6-32 THREAD<br>2.438 MAX .140 [3.56] DEEP<br>[61.93] Four Pole (CEL _ _ P and CML _ _ P only) M3 ISO THD OPTIONAL<br>(SEE NOTE 1)<br>DIM. "H"<br>(SEE TABLE) 8X 6-32 THREAD<br>[6.60].260 (SEE TABLE)DIM. "H" DIM. "H"(SEE TABLE) 10.21.402 M3 ISO THD OPTIONAL.140 [3.56] DEEP .2205.59<br>Notes:<br>Tolerance ± .015 [.39] unless noted. Dimensions in brackets [ ] are millimeters. 2.49063.25<br>A Terminal protrusion dimensions are referenced from back of mounting panel. 1.438 OFF OFF OFF OFF<br>B Each screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mm screw, 36.53 2.060<br>flatwasher and external tooth lockwasher. 52.32<br>C Stud terminals are supplied with a flatwasher, external tooth lockwasher and<br>a 10-32 or M5 hex nut (<=70A), 1/4 -20 or M6 hex nut (>70A).<br>D Units are supplied without bus bars must have a minimum copper strap (1<br>31/32 x 1/2 x 1/16 ) of appropriate length to accommodate connections tying<br>E each set of terminals together.Other spacing available upon request. Contact factory for assistance. [76.33]3.005 MAX<br>**----- End of picture text -----**<br> **151** _IAL Series - Handles_ http://airpax.sensata.com ## **IALN/IULN PANEL SEAL CIRCUIT PROTECTORS** The lALN/IULN family is a sealed toggle version of the IAL/IUL family. The silicone rubber seal around the handle assures panel seal integrity and makes this style a natural for harsh environments. This sealed toggle family is available in one to three pole models with ratings of .050 to 100 amperes. **==> picture [191 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> .130<br>[3.30] 6-32 MTG. SCREW<br>FOR HIGH SHOCK<br>MTG.<br>LOCKWASHER<br>ON<br>OFF<br>1/2-32 HEX NUT<br>.142 2.040<br>[3.61] [51.82] .625 .750<br>[15.88] [19.05]<br>**----- End of picture text -----**<br> **==> picture [213 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Single Pole Two Pole<br>**----- End of picture text -----**<br> **==> picture [45 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Three Pole<br>**----- End of picture text -----**<br> **==> picture [455 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> KEYWAY<br>.060 [1.52]-.065 [1.65] WIDE<br>.030 [.76]-.035 [.89] DEEP 1.515 2.265<br>.750 [38.48] [57.53]<br>[19.05] MAX. MAX.<br>1.375<br>[34.92]<br>2.490<br>[63.25]<br>.656<br>[16.66]<br>(Optional handle may be in<br>pole 2 instead<br>of pole 1.)<br>**----- End of picture text -----**<br> Panel Mounting Details: Tolerance ±.005 [.13] Unless noted. **==> picture [476 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> Single Pole Two Pole* Three Pole*<br>.750 .750 .750<br>[19.05] [19.05] [19.05]<br>Ø.156 MAX. MAX. MAX.<br>[3.96]<br>.656<br>[16.66] Ø.515<br>[13.08]<br>Optional handle *See Single Pole Mounting Detail for Hole<br>Sizes and Locations.<br>**----- End of picture text -----**<br> Notes: A Terminal protrusion dimensions are referenced from back of mounting panel. B Each screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher. C Stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or M5 hex nut (<=70A), 1/4 -20 or M6 hex nut (>70A). _IAL Series - Handles_ **152** **==> picture [612 x 60] intentionally omitted <==** ## **IALX/IULX/IELX ROCKER HANDLE** **==> picture [403 x 243] intentionally omitted <==** **----- Start of picture text -----**<br> The rocker style is available in one to four poles. Choose<br>either vertical or horizontal mounting with ON-OFF, 1.859<br>international markings or a combination of both. [47.22]<br>2.490 1.375<br>Five front panel enhancing colors including black, white, red, [63.25] 1.940 [34.92]<br>grey and orange are available. [49.28]<br>[3.61]<br>2.249 .419<br>[57.12] [10.65]<br>Single Pole<br>M3 ISO THD.2X 6-32 THD. (TYP.) Two Pole Three Pole Four Pole<br>OPTIONAL<br>.750<br>[19.05]<br>2.361<br>1.972<br>[50.09] ON ON ON ON<br>ON 1.660<br>[42.16] 1.260<br>OFF OFF OFF OFF [32.00]1.260<br>OFF<br>[19.05].750 (HANDLE WIDTH).735[18.67] [38.07]1.499MAX. [57.12]2.249MAX. [76.58]3.015MAX. [5.08].200.200<br>**----- End of picture text -----**<br> Panel Mounting Detail* Four Pole** Single,Two & Three Pole **==> picture [169 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> .750<br>[19.05] 1.510<br>[38.35]<br>[32.00]1.260 1.660 [32.00]1.260<br>[42.17]<br>[5.08].200.200 2X Ø .156[3.96] [19.05].750<br>**----- End of picture text -----**<br> (Optional handle may be in Pole 2 instead of Pole 1.) Note: - A Terminal protrusion dimensions are referenced from back of mounting panel. *Mounting detail tolerance ±.005 [.13] Unless noted. - **See single mounting detail for hole sizes and locations. - B Each screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher. - C Stud terminals are supplied with a flatwasher, external tooth lock washer and a 10-32 or M5 hex nut (<=70A), º -20 or M6 hex nut (>70A). ## **IALZX/IULZX/IELZX ROCKER HANDLE** The IALZX/IULZX/IELZX style adds our rocker handle options of contrasting dual color rocker actuators, affording a clear visual indication of the handle position and integrated handle guards, to help prevent accidental turn-on and turn-off of the unit. Available with a black rocker and white, red or green indicator color for either ON or OFF indication. **==> picture [268 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> 2.173 MAX. .420 REF<br>[55.19] [10.67]<br>1.859<br>[47.22] .201 .750 MAX.<br>[5.11] [19.05]<br>.772<br>[19.62]<br>1.395<br>[35.43]<br> 2.490 MAX.<br>[63.25] ON 1.660<br>[42.16]<br>OPTIONAL OFF<br>HANDLE GUARDS<br>1.239<br>[31.47]<br>.314 .506<br>[7.98] [12.85] 2X 6-32 THD.M3 ISO THD.<br>OPTIONAL<br>Note: Tolerance ± .015 [.38] unless noted.<br>Dimensions in brackets [ ] are millimeters.<br>**----- End of picture text -----**<br> Panel Mounting Detail **==> picture [67 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> .750<br>[19.05]<br>1.660<br>[42.17] 1.260<br>[32.00]<br> 2X Ø .156 .200<br>[3.96] [5.08]<br>**----- End of picture text -----**<br> Panel Mounting Detail Tolerance ±.005 [.13] unless noted. **153** _IAL Series - Handles_ http://airpax.sensata.com **==> picture [94 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Series and Switch Only<br>**----- End of picture text -----**<br> ## **CONFIGURATIONS** ## **Series Trip** The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indicates circuit status. In addition to providing conventional overcurrent protection, it’s simultaneously used as an on-off switch. **==> picture [133 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> .281[7.13] Dimension B(See Table)<br>SERIES SWITCH ONLY<br>1.940<br>[49.28]<br>Dimension A<br>(See Table)<br>**----- End of picture text -----**<br> Series with Auxiliary Switch ## **Shunt Trip** The shunt trip is designed for controlling two separate loads with one assembly. The control is established by providing overload protection for the critical load. When the current through this load becomes excessive and reaches the trip point, the protector will open and remove power from both loads simultaneously. The total current rating of both loads must not exceed the maximum contact rating. ## **Dual Coil** By combining two electrically independent coils on a common magnetic circuit, it is possible to provide contact opening when either an over-current or trip voltage is applied to the respective coils. One coil will be a current trip coil with standard specifications. The second, or dual coil, can be used to provide a control function permitting contact opening from a remote interlock or other transducer functions. Standard coils are 6, 12, 24, 48, 120 and 240 volts. Tripping is instantaneous and must be removed (usually self-interrupting) after trip. **==> picture [151 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> .648<br>[16.46]<br>C<br>NO<br>1.055 NC<br>1.290 [26.80]<br>[32.77] BREAKER IN OFF POSITION<br>**----- End of picture text -----**<br> **==> picture [263 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> STUD TERMINAL TYPES<br>Screw Stud Thread Dimension “A” Dimension “B”<br>.510 ± .045 .652 ± .035<br>M6<br>[12.95 ± 1.14] [16.56 ± 0.89]<br>.545 ± .045 .687 ± .035<br>1/4 -20<br>[13.84 ± 1.14] [17.45 ± 0.89]<br>.510 ± .045 .652 ± .035<br>M5<br>[12.95 ± 1.14] [16.56 ± 0.89]<br>.545 ± .045 .687 ± .035<br>10-32<br>[13.84 ± 1.14] [17.45 ± 0.89]<br>**----- End of picture text -----**<br> Shunt and Dual Coil ## **Auxiliary Switch (Applies to Series Trip Only)** This is furnished as an integral part of a series pole in single or multi-pole assemblies. Isolated electrically from the protector’s circuit, the switch works in unison with the power contacts and provides indication at a remote location of the protector’s on-off status. Auxiliary switch contacts actuate simultaneously with the main breaker contacts, and will open regardless of whether the breaker contacts are opened manually or electrically. For auxiliary switch ratings below 6Vac or 5Vdc, an auxiliary switch with gold contacts, designated as REG is available. Gold contacts are not recommended for load current above 100 milliamps. ## Note: - A Terminal protrusion dimensions are referenced from back of mounting panel. - B Each screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher. - C Stud terminals are supplied with a flatwasher, external tooth lock washer and a 10-32 or M5 hex nut (<=70A), 1/4-20 or M6 hex nut (>70A). **==> picture [92 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension B<br>.278 (See Table)<br>[7.05]<br>1.26 .660 ±.045<br>[32.00] [16.76] ±1.14]<br>1.940<br>[49.28]<br>.795<br>[20.19] 2.640 MAX.<br>[67.06]<br>(SEE NOTE A)<br>**----- End of picture text -----**<br> **==> picture [48 x 119] intentionally omitted <==** **==> picture [252 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> SHUNT DUAL COIL<br>Spacing for V D E S witch<br>2.454 MAX.<br>.187 [64.52]<br>[4.75] (SEE NOTE A)<br>[24.6.971 6] [17.17] .676<br>[32.16]1.266 -IREC5 .250[6.35]<br>2.438 MAX.<br>[2.79].110 [64.52](SEE NOTE A)<br>.260<br>Note: Each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut. -IREC4, -IREG4[6.60]<br>**----- End of picture text -----**<br> _IAL Series - Configurations_ **154** **==> picture [612 x 60] intentionally omitted <==** ## **CONFIGURATIONS (CONT.)** ## **Relay Trip** This permits the overload sensing coil to be placed in a circuit which is electrically isolated from the trip contacts. The coil may be actuated by sensors monitoring pressure, flow, temperature, speed, etc. Other typical applications include crowbar, interlock and emergency/rapid shutdown circuitry. Trip may be accomplished by voltage or current, which must be removed after trip. ## **Voltage Trip** Sometimes called “dump circuits” or “panic trip circuits,” these units make it possible to open main power contacts with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt or relay configurations. **==> picture [250 x 211] intentionally omitted <==** **----- Start of picture text -----**<br> FIG.1 FIG.2<br>Barriers<br>1.378<br>1.098 [35.00] .303<br>[27.89] .952 [7.69]<br>.670 .122 [24.18]<br>[17.02] [3.11]<br>3.100<br>2.740 [78.74]<br>[69.60]<br>FIG.3 FIG.4<br>**----- End of picture text -----**<br> **==> picture [531 x 418] intentionally omitted <==** **----- Start of picture text -----**<br> Relay and Dual Coil<br>.795<br>.660[20.19] [±.045] [29.13]1.147 [29.13]1.147<br>.281 [16.76±1.14] [18.31].721 [.84].033 [18.31].721 [.84].033<br>[7.14]<br>.722<br>1.330 [18.34] [65.02]2.560 [65.02]2.560<br>[33.78]<br>1.940<br>[49.28]<br>NOTE:<br>THIS BARRIER CAN BE FLIPPED<br>TO COVER EITHER POLE.<br>2.640 MAX PLEASE CONTACT FACTORY FOR SPECIFIC PART NUMBER<br>BARRIER OPTIONS<br>Standard Optional<br>Rating Option<br>Barrier Barrier<br>RELAY DUAL COIL IEL<br>240/415 VAC<br>415 VAC (VDE)<br>Fig. 1 Fig. 2, 3 & 4<br>Notes: 277/480 VAC<br>Tolerance ± .015 [.39] unless noted. Dimensions in brackets [ ] are millimeters.<br>1/4-20, M6 studs for AC<br>A Terminal protrusion dimensions are referenced from back of mounting panel.<br>B Each screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mm screw, 120/240 VAC multi-pole<br>flatwasher and external tooth lockwasher. Fig. 2 Fig. 3 & 4<br>125VDC<br>C Stud terminals are supplied with a flatwasher, external tooth lockwasher and<br>a 10-32 or M5 hex nut (<=70A), 1/4 -20 or M6 hex nut (>70A). LEL<br>All multi-pole 50/60 Hz Fig. 2 Fig. 3 & 4<br>All multi-pole 80 VDC, if opposite polarity Fig. 2 Fig. 3 & 4<br>125VDC Fig. 2 Fig. 3 & 4<br>Note: Optional barrier available with factory assigned part number. Contact<br>factory for assistance.<br>**----- End of picture text -----**<br> _IAL Series - Configurations_ http://airpax.sensata.com **155** ## **Mid-Trip Indication** Circuit protection, rapid fault location and alarm capability are blended together in the Airpax mid-trip indication option. This option is designed for automatic handle movement to a middle position upon electrical overload, allowing for easier detection of the fault circuitand minimizing downtime due to the overload condition. In the optional auxiliary switch configuration, the switch allows an alarm or signal to be forwarded when the breaker trips and the handle moves to the middle position. The alarm can be disengaged by the manual actuation of the handle to the OFF position. Once the fault has been corrected, the circuit breaker can be reset to the ON position. The mid-trip option is available in one, two or three pole toggle handle packages and in either standard panel screw or snap-in mounting. Please see specification tables of specific product for available ratings. ## **Snap-In Mounting** The snap-in mounting adapter allows for simplified mounting of most IEL/LEL toggle handle products. Prior to shipment, the adapter is attached to the circuit breaker during our final product assembly, allowing you to securely snap the unit into a rectangular panel cut-out. This eliminates the need for panel mounting hardware and associated assembly costs. Available for units up to three poles, with or without an option handle guard. Note: Tolerance ± .015 [.39] unless noted. Dimensions in brackets [ ] are millimeters. Panel Mounting Detail Tolerance ±.005 [.13] unless noted. **==> picture [301 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> Mid-Trip Handle Panel Mounting<br>Positions Detail<br>C<br>NO<br>NC<br> BREAKER IN ON OR MANUALLY<br>MID-TRIP TURNED OFF POSITION<br>POSITION 2.938 [±.007]<br>C [74.63 [±.18]]<br>NO<br>NC<br> BREAKER IN MID-TRIP<br> POSITION (ELECTRICALLY<br> TRIPPED)<br>DIM.“A”<br>(SEE TABLE)<br> ONPOSITION<br> OFF<br>POSITION<br>**----- End of picture text -----**<br> **==> picture [336 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 2.061 .995 1.750 2.495<br>[52.35] [25.27] [44.45] [63.37]<br>3.220<br>[81.79]<br>**----- End of picture text -----**<br> **==> picture [317 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> .687<br>[17.45]<br>1.560<br>[39.62]<br>**----- End of picture text -----**<br> |**PANEL MOUNTING OPTIONS**|**PANEL MOUNTING OPTIONS**|**PANEL MOUNTING OPTIONS**| |---|---|---| |**# of Poles**|**Dimension “A”**|**Panel Thickness**| |1 pole|.760 ± .007<br>[19.30 ± .18]|.062 ± .005<br>[1.57 ± .13]| |2 pole|1.530 ± .007<br>[38.86 ± .18]|.062 ± .005<br>[1.57 ± .13]| |3 pole|2.280 ± .007<br>[57.91 ± .18]|.062 ± .005<br>[1.57 ± .13]| _IAL Series - Configurations_ **156** **==> picture [612 x 60] intentionally omitted <==** ## **OPERATING CHARACTERISTICS** ## **NOMINAL DCR /IMPEDANCE** |**NOMINAL DCR /IMPEDANCE**|**NOMINAL DCR /IMPEDANCE**|**NOMINAL DCR /IMPEDANCE**|**NOMINAL DCR /IMPEDANCE**| |---|---|---|---| |**Current Ratings**<br>**(Amps)**|**Resistance (ohms)**|**Impedance (ohms)**|**Impedance (ohms)**| ||**DC Delays**|**AC, 50/60Hz Delays**|**AC, 400Hz Delays**| ||**_51, 52, 53, 59_**|**_61, 62, 63, 69_**|**_41, 42, 43, 49_**| |0.20|45.8|28.5|71.94| |1.0|1.38|1.10|2.85| |2.0|0.371|0.29|0.76| |5.0|0.055|0.051|0.12| |10.0|0.017|0.016|0.032| |20.0|0.006|0.006|0.010| |30.0|0.003|0.004|0.006| |50.0|0.0019|0.0018|0.0019| |60.0|0.00157|0.00134|—| |70.0|0.00147|0.00133|—| |80.0|0.00146|0.00123|—| |90.0|0.00135|0.00114|—| |100.0|0.00135|0.00114|—| |125.0|0.0005|—|—| |150.0**|0.0005|—|—| |165.0**|0.0004|—|—| |175.0**|0.0004|—|—| |200.0**|0.0004|—|—| |250.0**|0.0004|—|—| |400**|0.0003|—|—| |_Notes:_<br>_DCR and impedance based on 100% rated current applied and stablized a minimum of one hour._<br>_No 53 delay on 125 amp single pole or 400 amp four pole devices_<br>_Tolerance: .02 amperes to 2.5 amperes, ± 20%; 2.6 amperes to 20 amperes, ± 25%; 21 amperes to 50 amperes, ± 50%. Consult factory for special values and for coil_<br>_impedance of delays not shown_<br>_** Paralleled poles only, 400 amps only available on CELHP_|||| **14957** _IAL Series - Operating Characteristics_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## **PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C** |**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C**| |---|---|---|---|---|---|---|---|---| |**Delay**|**100%**|**125%***|**150%**|**200%**|**400%**|**600%**|**800%**|**1000%**| |41*|No Trip|May trip|.5 to 8|.15 to 1.9|.02 to .4|.006 to .25|.004 to .1|.004 to .05| |42*|No Trip|May trip|5 to 70|2.2 to 25|.40 to 5|.012 to 2|.006 to .2|.006 to .15| |43*|No Trip|May trip|35 to 350|12 to 120|1.5 to 20|.012 to 2.2|.01 to .22|.01 to .1| |49*|No Trip|May trip|.100 max.|.050 max.|.020 max.|.020 max.|.020 max.|.020 max.| |51|No Trip|.5 to 6.5|.3 to 3|.1 to 1.2|.031 to .5|.011 to .25|.004 to .1|.004 to .08| |52|No Trip|2 to 60|1.8 to 30|1 to 10|.15 to 2|.04 to 1|.008 to .5|.006 to .1| |53**|No Trip|80 to 700|40 to 400|15 to 150|2 to 20|.23 to 9|.015 to .55|.012 to .2| |59|No Trip|.120 max.|.100 max.|.050 max.|.022 max.|.017 max.|.017 max.|.017 max.| |61|No Trip|.7 to 12|.35 to 7|.130 to 3|.030 to 1|.015 to .3|.01 to .15|.008 to .1| |62|No Trip|10 to 120|6 to 60|2 to 20|.2 to 3|.02 to 2|.015 to .8|.01 to .25| |63|No Trip|50 to 700|30 to 400|10 to 150|1.5 to 20|.4 to 10|.013 to .85|.013 to .5| |69|No Trip|.120 max|.100 max.|.050 max.|.022 max.|.017 max.|.017 max.|.017 max| |71|No Trip|.44 to 10|.3 to 7|.100 to 3|.030 to 1|.012 to .3|.004 to .15|.004 to .1| |72|No Trip|1.8 to 100|1.7 to 60|1 to 20|.15 to 3|.015 to 2|.008 to .79|.006 to .28| |73|No Trip|50 to 600|30 to 400|10 to 150|1.8 to 20|.015 to 10|.015 to .88|.011 to .5| |79|No Trip|.120 max|.100 max.|.050 max.|.023 max.|.016 max.|.015 max.|.015 max| |_Notes:_<br>_All trip curves and trip currents are specifed with the protector mounted in the normal vertical position at ambient temperature of +25° C. Protectors do not carry_<br>_current prior to application of overload. A: Ratings above 30 amps may deviate from the above limits by approximately 10% (130% for delay 49)._<br>_* No 53 delay on 125 amp single pole or 400 amp four pole devices_<br>_* 135% for delay 71, 72, 73 & 79_||||||||| _**IAL/CEL/LEL Series - Operating Characteristics** IAL Series - Operating Characteristics_ **1508** _http://airpax.sensata.com/_ **==> picture [612 x 60] intentionally omitted <==** ## **DELAY CURVES** ## **400Hz, DC, 50/60Hz Delay Curves (typ)** ## **Inrush Pulse Tolerance** A choice of delays is offered for DC, 50/60Hz, 400Hz, or combined DC/50/60Hz applications. Delays 49, 59, 69 and 79 provide fast-acting, instantaneous tripping and are often used to protect sensitive electronic equipment (not recommended where a known inrush exists). Delays 41, 51, 61 and 71 have a short delay for general purpose applications. Delays 42, 52, 62 and 72 are long enough for most transformers and capacitor loads. Delays 43, 53, 63 and 73 are extra long for special motor applications. Pulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. The table on page 171 provides a guide to determine if the inertia delay feature is required. Consult factory for further assistance. **==> picture [502 x 364] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>1000 DELAY 61 1000 DELAY 62<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 0 100 150 200 300 400 500 600 700 800 900 1000 .001 0 100 150 200 300 400 500 600 700 800 900 1000<br>125 125 PERCENT OF RATED CURRENT<br>PERCENT OF RATED CURRENT<br>10000 10000<br>1000 DELAY 63 1000 DELAY 69<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 0 100125150125150150 200 300 400 500 600 700 800 900 1000 .001 0 100125150 200 300 PERCENT OF RATED CURRENT400 500 600 700 800 900 1000<br>MAY TRIP MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>Y TRIPAM<br>MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [204 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 63<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100125150125150150 200 300 PERCENT OF RATED CURRENT400 500 600 700 800 900 1000<br>MAMY TRIPAM<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **1495** _IAL Series - Delay Curves_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## **DC Delay Curves (typ)** **==> picture [204 x 363] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 51<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 52<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> |**PULSE TOLERANCES**|**PULSE TOLERANCES**| |---|---| |**Delay**|**Pulse Tolerance**| |61, 62, 63, 71, 72, 73|10 times (approx.) rated current| |61F, 62F, 63F, 71F, 72F, 73F|12 times (approx.) rated current| |64, 65, 66 (0 - 50A)|25 times (approx.) rated current| |64, 65, 66 (>50 - 80A)|20 times (approx.) rated current| |64, 65, 66 (>80 - 100A)|18 times (approx.) rated current| **==> picture [205 x 363] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 53<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125 PERCENT OF RATED CURRENT<br>10000<br>1000 DELAY 59<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>125<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> _**IAL/CEL/LEL Series - Operating Characteristics** IAL Series - Delay Curves_ **1506** _http://airpax.sensata.com/_ **==> picture [612 x 60] intentionally omitted <==** ## **400Hz Delay Curves (typ)** *Available only in IAL/IUL/IEL; not available in LEL. **==> picture [504 x 361] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>1000 DELAY 41 1000 DELAY 43<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 .001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>125 PERCENT OF RATED CURRENT 125 PERCENT OF RATED CURRENT<br>10000 10000<br>1000 DELAY 42 1000 DELAY 49<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 .001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>125 130<br>PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT<br>MAY TRIP<br>MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>MAY TRIP<br>MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>**----- End of picture text -----**<br> **==> picture [202 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 DELAY 49<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>130<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> **14961** _IAL Series - Delay Curves_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## **DC/50/60Hz Dual-frequency Delay Curves (typ)** **==> picture [539 x 393] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>1000 DELAY 71 1000 DELAY 72<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 .001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>135 PERCENT OF RATED CURRENT 135 PERCENT OF RATED CURRENT<br>10000 10000<br>1000 DELAY 73 1000 DELAY 79<br>100 100<br>10 10<br>1 1<br>.1 .1<br>.01 .01<br>.001 .001<br>0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000<br>135 PERCENT OF RATED CURRENT 135 PERCENT OF RATED CURRENT<br>MAY TRIP MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>MAY TRIP<br>MAY TRIP<br>TIME IN SECONDS TIME IN SECONDS<br>**----- End of picture text -----**<br> _**IAL/CEL/LEL Series - Operating Characteristics** IAL Series - Delay Curves_ _http://airpax.sensata.com/_ **15062** **==> picture [612 x 60] intentionally omitted <==** ## **IAL/IUL/IEL/IDL/LEL SPECIFICATIONS** ## **Trip Free** Will trip open on overload even when forcibly held in the ON position. This prevents the operator from damaging the circuit by holding the breaker on. ## **Moisture Resistance** Meet all the requirements of MIL-PRF-55629 when tested in accordance with Method 106 of MIL-STD-202. ## **Shock** ## **Trip Indication** The operating handle moves positively to the OFF or mid-trip position on electrical overload. Circuit protectors shall not trip when tested per MIL-STD-202, Method 213, Test Condition I with 100% rated current applied to delayed units and 80% rated current to instantaneous units. ## **Ambient Operation** IAL/IUL/IEL protectors operate in temperatures between –40°C to +85°C. ## **Insulation Resistance** ## **Vibration** Circuit protectors shall not trip when vibrated per MILSTD-202, Method 204, Test Condition A with 100% rated current applied to delayed units and 80% rated current to instantaneous units. Not less than 100 megohms at 500 volts DC. ## **UL-1500 (Marine Ignition Protected)** ## **Dielectric Strength** IAL/IUL/IEL protectors withstand 3750Vac (1250Vac for LEL), 60Hz for 60 seconds between all electrically isolated terminals except auxiliary switch terminals shall withstand 600Vac, 60Hz for REG and REC types. Four terminal dual coil and relay construction (not offered in the LEL) will withstand 1500Vac. The IDL/IDLH is approved for Marine Ignition Protection (series configuration only), covering ignition protected circuit breakers. This specification requires devices to be used in accordance with the requirementsof U.S. Coast Guard and Fire Protection Standard for Pleasure and Commercial Motor Craft, ANSI/MFPA #302. ## **Endurance** Operating as a switch, the operating life exceeds 10,000 operations, 6000 at rated load, 4000 without load, at a rate of 6 per minute. ## **APPROXIMATE WEIGHT PER POLE** ## **Electrical Characteristics** .050-100 amperes 80Vdc, 240Vac Max., 240/415Vac at 50 amperes Max., 50/60Hz and 400Hz. Consult factory for specific product ratings. Units rated for 240/415Vac and above 50 amperes are not suitable for across-the-line motor starting. ||**Ounces**<br>3.1|**Grams**<br>90| |---|---|---| ## **Poles** One through six poles available. ## **Construction** Series, shunt, relay dual coil and series with auxiliary switch available in various delays and combinations. ## **Auxiliary Switch** When supplied shall be S.P.D.T. configuration. Non VDE approved switches have a maximum UL rating of 10.0 amperes, 250 volts, 60Hz; 3.0 amperes, 50 volts DC (REC type) or 0.1 amperes, 125 volts, 60Hz (REG type). VDE approved switches have a maximum UL rating of 10.0 amperes, 250 volts, 60Hz (REC type); or 0.1 amperes, 125 volts, 60Hz (REG; type). The maximum VDE ratings are 1.0 amperes, 125 volts, 60Hz (REC type); 0.1 amperes, 125 volts, 60Hz (REG type). ## **Salt Spray (Corrosion)** Meet the requirements of MIL-PRF-55629 when tested in accordance with Method 101 of MIL-STD-202. ## **RECOMMENDED TORQUE SPECIFICATIONS** |**RECOMMENDED TORQUE SPECIFICATIONS**|**RECOMMENDED TORQUE SPECIFICATIONS**| |---|---| |**Component**|**Torque (in-lbs)**| |6-32 MountingInserts|6 to 8| |M3 MountingScrews|4 to 5| |10-32 Screw Terminals|14 to 15| |M5 Terminal Screws|14 to 15| |10-32 Stud Terminals|13 to 14| |M5 Stud Terminals|13 to 14| |1/4 - 20 Stud Terminals|40 to 45| |M6 Stud Terminals|40 to 45| |1/2 - 32 MountingBushing|30 to 35| |_Where applicable, mechanical support must be provide to the_<br>_terminals when applying torque_|| **14963** _IAL Series - Specifications_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## **IAL/IUL/IEL/IDL/LEL/LELHP SPECIFICATIONS** ## **AGENCY APPROVALS - IAL/IUL/IEL** |**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**|**AGENCY APPROVALS - IAL/IUL/IEL**| |---|---|---|---|---|---|---|---|---|---| |Voltage|Frequency<br>(Hz)|Phase|Min.<br>Poles|TC|OL|UL/CSA|VDE<br>(amps)|UL 1077 & CSA<br>(AIC)|VDE<br>(AIC)| |65|DC|-|1|1|1|.02-100|.10-70|U2,7500|4000| |65(4)|DC|-|1|1|1|.02-100|-|U2,3000|-| |65(4)|DC|-|1|1|1|.02-50|-|U2,5000|-| |65|DC|-|2**|2|1|101-150|-|U2,7500|-| |80|DC|-|1|1|1|.02-70|.10-50|U2,7500|4000| |80|DC|-|1|1|1|70.1-100|-|U2,5000|-| |80|DC|-|2|1|1|101-150|-|U1,10000|-| |80|DC|-|3|1|0|251-300|-|U2,7500|-| |125|DC|-|2|1|0|.02-100|-|U2,5000|-| |250|DC|-|2+|1|0|.02-50|-|U1,5000|-| |300|DC|-|3++|1|0|.02-50|.10-50|U2,1000|5000| |125|50/60|1|1|1|0|.02-70|-|U2,5000|-| |125|50/60|1|1|1|1|.02-100|-|U1,3000|-| |125(5)|50/60|1|1|1|1|.02-100|-|U3,1500|-| |120/240|50/60|1|2|2|1|.02-100|-|U1,2000|-| |125/250(5)|50/60|1|2 only|1|1|.02-100|-|U3,1500|-| |240|50/60|1&3|1|1|0|.02-70|-|U1,2000|-| |240|50/60|3|2|1|1|.02-100|-|U2,2000|-| |250|50/60|3|1|1|1|.02-50|.10-100|U2,3000|2000| |250|50/60|3|1|1|1|.02-50|.10-100|C2,5000(1)|2000| |250|50/60|1|1|1|1|.02-50|.10-100|C2,5000(2)|2000| |250|50/60|3|2|1|0|.02-80|.10-100|U1,1000|2000| |250|50/60|3|1|1|0|.02-60|.10-100|U1,5000|2000| |250(5)|50/60|3|3 only|1|1|.02-100|-|U3,2000|-| |277|50/60|1|1|1|1|.02-50|-|U2,2000|-| |277|50/60|1&3|1|2|1|.02-50|-|C2,5000(1)|-| |240/415|50/60|3|2|2|0|.02-50|.10-50|U2,2000|2000| |240/415|50/60|1|2|2|0|.02-50|.10-50|C2,5000(1)|2000| |277/480|50/60|3|2|2|1|.02-30|-|U2,2000|-| |277/480|50/60|3|2|2|1|.02-50|-|U2,1200|-| |277/480|50/60|3|2|1|1|.02-30|-|C2,5000(3)|-| |277480|50/60|1&3|2|1|0|.02-50|-|C2,5000(3)|-| |480|50/60|1&3|2|1|1|.02-30|-|C2,5000(3)|-| |480|50/60|3|2|1|0|.02-50|-|C2,5000(3)|-| |250|400|1&3|1|2|1|.02-50|-|U2,1500|-| ## **AGENCY APPROVALS - IDL/IDLP (MARINE)** |**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**|**AGENCY APPROVALS - IDL/IDLP (MARINE)**| |---|---|---|---|---|---|---|---|---|---| |Voltage|Frequency<br>(Hz)|Phase|Min.<br>Poles|TC|OL|UL/CSA|VDE<br>(amps)|UL 1077 & CSA<br>(AIC)|VDE<br>(AIC)| |48|DC|-|1|1|1|.02-100|-|U1,5000|-| |48|DC|-|2**|1|1|101-150|-|U1,5000|-| |65|DC|-|1|1|1|.02-60|-|U1,1000|-| |80|DC|-|1|1|1|.02-100|-|U2,1500|-| |125|50/60|1|1|1|1|.02-100|-|U 1,1500|-| |250|50/60|1|2|1|1|.02-100|-|U2,1500|-| |250|50/60|1&3|1|1|1|.02-60|-|U1,1000|-| |**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**|**AGENCY APPROVALS - IULQ (TAPPED COIL)**| |---|---|---|---|---|---|---|---|---|---| |Voltage|Frequency<br>(Hz)|Phase|Min.<br>Poles|TC|OL|UL/CSA|VDE<br>(amps)|UL 1077 & CSA<br>(AIC)|VDE<br>(AIC)| |125/250|50/60|1|1|1|1|2/1-30/15|-|C2,5000(1)|-| |**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**|**AGENCY APPROVALS - IULD (DUST SEALED)**| |---|---|---|---|---|---|---|---|---|---| |Voltage|Frequency<br>(Hz)|Phase|Min.<br>Poles|TC|OL|UL/CSA|VDE<br>(amps)|UL 1077 & CSA<br>(AIC)|VDE<br>(AIC)| |250|50/60|1&3|1|1|1|.02-100|-|C2,5000(3)|-| |277|50/60|1|1|1|1|.02-30|-|C2,5000(3)|-| |Notes:<br>** Paralleled poles; + 2 poles in series; ++ 3 poles in series; (1) With 125 A max. series fuse; (2) Series<br>combination with 209 or 229 series (100 A max.); (3) With 100 A max. series fuse; (4) With blocked vent<br>construction (5) Non-standard construction. “Fit for further use” approval|||||||||| ## **AGENCY APPROVALS - LEL/LELHP** |**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**|**AGENCY APPROVALS - LEL/LELHP**| |---|---|---|---|---|---|---|---| |Voltage|Frequency<br>(Hz)|Phase|Min.<br>Poles|UL/CSA|VDE<br>(amps)|UL489<br>(AIC)|VDE<br>(AIC)| |65|DC|-|1|.05-50|-|7500|-| |65|DC|-|2**|101-150|-|50 000|-| |65|DC|-|3**|175-200|-|50000|-| |80|DC|-|1|.05-100|.10-100|10000|2000| |80|DC|-|1|.05-100|-|50000|-| |80|DC|-|2**|125-150|125-150|10000|2000| |80|DC|-|3**|175-200|151-200|10000|2000| |125|DC|-|1|.05-70|.05-70|5000|3000| |125/250|DC|-|2|.05-50|-|5000|-| |125|50/60|1&3|1|.05-40|-|10000|-| |125|50/60|1&3|1|.05-50|.10-50|5000|2000| |120/240|50/60|1|2|.05-70|.10-50|5000|2000| |240|50/60|1&3|1|.05-20|-|5000|-| |**AGENCY APPROVALS - CELHP**|||||||| |80|DC|-|4|400|-|10000 AIC<br>(UL489A)|-| ## **AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)** |**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**|**AGENCY APPROVALS - CEL/CELP (COMMUNICATIONS)**| |---|---|---|---|---|---|---|---| |Voltage|Frequency<br>(Hz)|Phase|Min.<br>Poles|UL/CSA|VDE<br>(amps)|UL 489A<br>(AIC)|VDE<br>(AIC)| |65|DC|-|1|.05-50|-|7500|-| |65|DC|-|2**|101-150|-|50000|-| |80|DC|-|1|.05-100|-|50000|-| |80|DC|-|2**|101-200|-|10000|-| |80|DC|-|3**|201-250|-|10000|-| |125|DC|-|1|.05-70|-|5000|-| |80|DC|-|1|15.1-125|-|10000|-| General notes: - All supplementary protectors are of the overcurrent (OC) type - The family of protectors has been evaluated for end use application for use groups (UG) A, B, C and D - The terminals (FW) are suitable for factory wiring only (0) - The maximum voltage ratings for which the protectors have been tested are shown in the chart - The current is the amperage range that the protectors have been tested - The tripping current (TC) for all of the protectors is either either “1” (in the range of 125% to 135% of ampere rating) or “2” (more than 135% of ampere rating) - The overload rating (OL) – designates whether the protector has been tested for general use or motor starting applications. - 0 – tested at 1.5 times amp rating for general use - 1 – tested at 6 times AC rating or 10 times DC rating for motor starting - The short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below: - C – Indicates short circuit test was conducted with series overcurrent protection - U – Indicates short circuit test was conducted without series overcurrent protection - 1 – Indicates a recalibration was not conducted as part of the short circuit testing - 2 – Indicates a recalibration was performed as part of the short circuit testing - 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further Use” rating _**IAL/CEL/LEL Series - Operating Characteristics** IAL Series - Specifications_ **15064** _http://airpax.sensata.com/_ **==> picture [612 x 62] intentionally omitted <==** ## **IAL/IUL/IEL DECISION TABLES** The ordering code for IAL/IUL/IEL/LEL circuit protectors may be determined by following the decision steps in the appropriate part number decision table subsequent to this page. The coding given permits a self-assigning part number but with certain limitations. Special applications may require a factory assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table, etc. With these, it is suggested that order entry be by description and/or drawings, and a part number will be established. Additionally, it is standard policy to establish a factoryassigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control. When specifying a circuit breaker for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection. For example the code shown is the code for a single pole breaker with a series construction and auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, rating of 20 amperes and a marked black handle, and is VDE approved. To determine the ordering number for your particular IAL/IUL/IEL unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have. ## Notes: IEL, IELH and IELX circuit protectors are designed to meet 8mm creepage clearance requirements for installation Category 111, Pollution Degree 3, Case A as measured in IEC 664. Intended for use in equipment to comply with IEC 950, 601 and VDE 0804 & 0805. **==> picture [285 x 304] intentionally omitted <==** **----- Start of picture text -----**<br> 1 First Decision<br>Select Type and Terminal<br>Type Description Terminal<br> IAL One handle per unit Standard screw terminal,<br>** IUL no designation required<br>*** IEL<br>K Stud terminals<br> IALH One handle per pole<br> ** IULH C Clip terminals<br> *** IELH B Bullet terminals<br> IALN One handle per unit<br> *** IULN panel seal<br> IALX ** IULX One handle per unit,rocker, bracket mounting 2 Second Decision<br> *** IELX Poles<br> IALZX One handle per unit, 1 Single pole<br> ** IULZX rocker, integral mounting<br> *** IELZX 11 Two pole<br>* IDL One handle per unit 111 Three pole<br>UL 1500<br>1111 Four pole*<br>* IDLH One handle per poleUL 1500 *Not available in toggle seal handle type.<br>Consult factory for 5 and 6 pole IEL part number.<br>One handle per unit<br>*** IML mid trip indication<br>*** IMLH One handle per pole Example:<br>mid trip indication<br> IALBX One handle per unit, IEL 1 - 1REC4- 61- 20.0 - 01 - V<br>** IULBX rocker, accidental-off<br>*** IELBX protection<br>** IMLBX One handle per unit,mid trip indication, rocker, 1 2 3 4 5<br>accidental-off protection<br> *UL Recognized<br> **UL Recognized, CSA Certified<br>***UL Recognized, CSA Certified, VDE Approved<br>**----- End of picture text -----**<br> ## **IEL 1 - 1REC4- 61- 20.0 - 01 - V** 1 2 3 4 5 7 ||||||4||**Fourth Decision**| |---|---|---|---|---|---|---|---| ||||||||Frequency & Delay| |||Internal Confguration<br>**Third Decision**<br>3<br>**-0**<br>**-1**<br>**-1REC4**<br>**-1REC5**<br>Switch only(50, 70 or 100 amp switch)<br>Series<br>Series with auxiliary switch*<br>.110 quick connect<br>Series with auxiliary switch*<br>.187 quick connect|||**SW**<br>**-41**<br>**-42**<br>**-43**<br>**-49**<br>**-51**<br>**-52**<br>**-53**||Switch only<br>400Hz short delay<br>400Hz long delay<br>400Hz motor start<br>400Hz 150% instant trip<br>DC short delay<br>DC long delay<br>DC motor start| |||**-1REG4**|Series with auxiliary switch||**-59**||DC 125% instant trip| ||||.110 quick connect||**-61**||50/60Hz short delay| |||**-1RS4**|Series with alarm switch,<br>electrical trip, .110 quick connect<br>terminals||**-62**<br>**-63**||50/60Hz long delay<br>50/60Hz motor start| |||**-1RLS4**|Series with alarm switch,||**-69**||50/60Hz 125% instant trip| ||||electrical trip, .110 quick connect<br>terminals (mid-trip only)||**-71**||DC/60Hz short delay| |||**-1RS5**|Series with alarm switch,||**-72**||DC/60Hz long delay| ||||electrical trip, .187 quick connect||**-73**||DC/60Hz motor start| ||||terminals||||| |||**-3**|Shunt||For<br>**-79**|DC/60 Hz 135% instant trip<br>addition of inertial delay, add an ìFî to any|| |||**-4**|Relay (not available in IEL/IELX)||delay numeral.||| * Only one auxiliary switch is normally supplied on two or three pole units. Switch is located in the right-hand pole (viewed from terminal end) unless otherwise specified. ## **V** = VDE and CCC Approved The shaded areas denote VDE and CCC (if applicable) Approval options. This approval requires the addition of a V at the end of the part number. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be VDE or CCC Approved, but other approvals still apply. ## **C** = CCC Approved This approval requires the addition of a C at the end of the part number. The unit will not be VDE Approved. Note: CCC Approval is pending. Note: CCC Approval is pending. _IAL Series - Decision Tables_ http://airpax.sensata.com **165** **==> picture [613 x 411] intentionally omitted <==** **----- Start of picture text -----**<br> 5 Rated Current Fifth Decision 6 Sixth Decision Optional ROCKER HANDLECOLOR INDICATING COLOR<br>Use three numbers to print required Standard hardware. No designation required. INDICATINGCOLOR ROCKER HANDLECOLOR<br>current value between minimum and 100 amps maximum. .100 amps -A Metric thread mounting inserts and terminals LINE LINE<br>For example, use:.100 or 2.00 or 10.0 -B Barrier Mounting/Indicator Code: A, B, CINDICATION “ON” Mounting/Indicator Code: F, G, HINDICATION “OFF”<br>-C 277V (50/60Hz only) (See note 3)<br>The VDE (lth) will be 95% of the LOAD ON ON LINE LOAD LINE LOAD LINE LOAD<br>UL/CSA rated current. -D 240/415V (50/60Hz only) LINE OFF O OFFO OFF ON OFF ON<br>-E 277V/480V (50/60Hz only) (See note 4) FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6<br>MARKING DETAIL “A” (SEE TABLE)<br>-G Handle guard, (available in ZX, BX and snap-in<br>versions only)<br>-K (<=70A requires -K, if >70A do not use -K)1/4 - 20 stud (M6 stud when -A option is selected) LINE<br>INDICATING<br>-L Handle lock COLOR<br>7 Seventh Decision -M Handle in opposite pole ROCKERHANDLECOLOR<br>-P Snap-in face plate adapter<br>Handle Color and Marking Selection<br>-U 120/240V 50/60Hz INDICATION “ON”<br>IAL, IUL, IEL, IALH, Mounting/Indicator Code: J, K, L<br>IULH, IELH - Toggle Handle -W Wire clamp supplied (VDE approved up to<br>and including 16.0 amps) LINE OFF O OFFO LOAD LINE LOAD LINE LOAD LINE<br> Marked* ON-OFF -X Handle guard with no actuation feature (BX rocker only) LOAD FIG. 1ON FIG. 2 FIG. 3ON ONFIG. 4OFF FIG. 5 ONFIG. 6OFF<br> Color Unmarked I-O MARKING DETAIL “B” (SEE TABLE)<br>-1 Silver 5/16" (.312") bullet<br>Black -00 -01 (STD) -2 Gold 5/16" (.312") bullet<br>Yellow -10 -11 Notes:<br>1. One or more descriptions may be used as required.<br>2. When this is not used, table one may be substituted and U.S. thread and<br>Red -20 -21 two lockwashers will be supplied. Unit will be rated at 250V (50/60Hz only.)<br>3. VDE approved at 250Vac<br>4. VDE approved at 415Vac<br>Blue -30 -31<br>Green -40 -41 LINE<br>Orange -60 -61 INDICATION “OFF”<br>Mounting/Indicator Code: M, N, P, R<br>White -90 -91 LOAD ON LINE LOAD<br>LINE O OFFO OFFO ON<br>FIG. 2 FIG. 3 FIG. 6<br>MARKING DETAIL “C” (SEE TABLE)<br>ONI<br>OFFO<br>I<br>O<br>OOFF I<br>OFF<br>ON<br>ON<br>IAL Series<br>O O<br>O O<br>**----- End of picture text -----**<br> **==> picture [442 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> 7 Seventh Decision<br>**----- End of picture text -----**<br> |7|7|7|7|7|7|7|7|7|7|7| |---|---|---|---|---|---|---|---|---|---|---| |Rocker Handle Color, Indicator Color and Marking Selection (See Notes)||||||||||| |IALX, IULX, IELX, IALZX, IULZX, IELZX Rocker Handle (Single Rocker Color)||||||||||| ||||||Vertical Mounting|||Horizontal Mounting||| |Rocker<br>Handle<br>Color|Indicating<br>Color|Marking<br>Color|Indicates:|Unmarked|On-Off<br>Fig.1|I-O<br>Fig.2|On-Off<br>I-O<br>Fig.3|On-Off<br>Fig.4|I-O<br>Fig.5|M<br>De<br>On-Off<br>I-O<br>Fig.6| |Black|N/A|White|N/A|**-00**|**-01**|**-02**|**-03**|**-04**|**-05**|**-06**<br>**-26**<br>**-46**<br>**-56**<br>**-96**| |Red|N/A|White|N/A|**-20**|**-21**|**-22**|**-23**|**-24**|**-25**|| |Grey|N/A|Black|N/A|**-40**|**-41**|**-42**|**-43**|**-44**|**-45**|| |Orange|N/A|Black|N/A|**-50**|**-51**|**-52**|**-53**|**-54**|**-55**|| |White|N/A|Black|N/A|**-90**|**-91**|**-92**|**-93**|**-94**|**-95**|| |IALZX, IULZX, IELZXRocker Handle (Dual Rocker Color)||||||||||| |Black|White|White|On|**-A0**|**-A1**|**-A2**|**-A3**|**-A4**|**-A5**|**-A6**<br>**-B6**<br>**-C6**<br>**-F6**<br>**-G6**<br>**-H6**| |Black|Red|White|On|**-B0**|**-B1**|**-B2**|**-B3**|**-B4**|**-B5**|| |Black|Green|White|On|**-C0**|**-C1**|**-C2**|**-C3**|**-C4**|**-C5**|| |Black|White|White|Off|**-F0**|**-F1**|**-F2**|**-F3**|**-F4**|**-F5**|| |Black|Red|White|Off|**-G0**|**-G1**|**-G2**|**-G3**|**-G4**|**-G5**|| |Black|Green|White|Off|**-H0**|**-H1**|**-H2**|**-H3**|**-H4**|**-H5**|| |Black|White|White|On|**-J0**|**-J1**|**-J2**|**-J3**|**-J4**|**-J5**|**-J6**<br>**-K6**<br>**-L6**| |Black|Red|White|On|**-K0**|**-K1**|**-K2**|**-K3**|**-K4**|**-K5**|| |Black|Green|White|On|**-L0**|**-L1**|**-L2**|**-L3**|**-L4**|**-L5**|| |IALBX,|IULBX, IELBX, L|ELBX Rocker Ha|ndle (Dual Rock|er Color)||||||| |Black|White|White|Off|**-M0**|N/A|**-M2**|**-M3**|N/A|N/A|**-M6**<br>**-N6**<br>**-P6**<br>**-R6**| |Black|Red|Red|Off|**-N0**|N/A|**-N2**|**-N3**|N/A|N/A|| |Black|Green|Green|Off|**-P0**|N/A|**-P2**|**-P3**|N/A|N/A|| |Black|Yellow|Yellow|Off|**-R0**|N/A|**-R2**|**-R3**|N/A|N/A|| |Notes: A. Bezels of IALBX, IULBX, IELB, IELBX are black.<br>B. Consult factory for other marking options.||||||||||| Notes: A. Bezels of IALBX, IULBX, IELB, IELBX are black. B. Consult factory for other marking options. **==> picture [612 x 36] intentionally omitted <==** **==> picture [612 x 60] intentionally omitted <==** ## **LEL DECISION TABLES** |1|**First Decision**|**First Decision**||**Fourth Decision**<br>4<br>Frequency and Delay<br>DC short delay<br>DC long delay<br>DC motor start<br>DC 125% instant trip<br>50/60Hz short delay<br>50/60Hz long delay<br>50/60Hz motor start<br>50/60Hz 125% instant trip<br>For addition of inertial delay, add an “F” to any<br>delay numeral.<br>*Not available above 100 amps.<br>**-51**<br>**-52**<br>**-53***<br>**-59**<br>**-61**<br>**-62**<br>**-63**<br>**-69**<br>The shaded areas denote VDE and CCC (if applicable)<br>Approval options. This approval requires the addition of<br>a V at the end of the part number. The V will be added to<br>any part number formed entirely from shaded decisions.<br>If non-shaded areas are selected, the unit will not be<br>VDE or CCC Approved, but other approvals still apply.<br>**V**= VDE and CCC Approved<br>The approval requires the addition of a C at the end<br>of the part number. The unit will not be VDE Approved.<br>**C**= CCC Approved<br>1<br>2<br>3<br>4<br>**LEL 1 - 1REC4 - 61 - 20.0 - 01 - V**<br>5<br>7<br>Example:<br>Terminal<br>Standard screw terminal,<br>no designation required<br>Stud terminals<br>Clipterminals<br>Bullet terminals|**Fourth Decision**<br>4<br>Frequency and Delay<br>DC short delay<br>DC long delay<br>DC motor start<br>DC 125% instant trip<br>50/60Hz short delay<br>50/60Hz long delay<br>50/60Hz motor start<br>50/60Hz 125% instant trip<br>For addition of inertial delay, add an “F” to any<br>delay numeral.<br>*Not available above 100 amps.<br>**-51**<br>**-52**<br>**-53***<br>**-59**<br>**-61**<br>**-62**<br>**-63**<br>**-69**<br>The shaded areas denote VDE and CCC (if applicable)<br>Approval options. This approval requires the addition of<br>a V at the end of the part number. The V will be added to<br>any part number formed entirely from shaded decisions.<br>If non-shaded areas are selected, the unit will not be<br>VDE or CCC Approved, but other approvals still apply.<br>**V**= VDE and CCC Approved<br>The approval requires the addition of a C at the end<br>of the part number. The unit will not be VDE Approved.<br>**C**= CCC Approved<br>1<br>2<br>3<br>4<br>**LEL 1 - 1REC4 - 61 - 20.0 - 01 - V**<br>5<br>7<br>Example:<br>Terminal<br>Standard screw terminal,<br>no designation required<br>Stud terminals<br>Clipterminals<br>Bullet terminals|5|**Fifth Decision**| |---|---|---|---|---|---|---|---| |Select Type and Terminal||||||Rated Current|| |Type<br>Description||||Terminal|||| |||||||Use three numbers to print (.050 or 1.50 or 100)<br>Value between**.050**amps and**100**amps.|| |**LEL**||One handle per unit|||Standard screw terminal,<br>no designation required||| |**LELH**||One handle per pole||||**Sixth Decision**<br>6<br>Optional|| ||||**K**||Stud terminals||| |**LML**||One handle per unit, mid-trip<br>indication|||||| ||||**C**||Clipterminals||| |**LMLH**||One handle per pole, mid-trip<br>indication|**B**||Bullet terminals||| ||||||||| |**LELZX**||One handle per unit, rocker,<br>integral mounting||||**-A**|Metric thread mounting inserts<br>and terminals| |**LMLZX**||One handle per unit, rocker,<br>mid-trip indication, integral mounting|||||| |||||||**-B**|Barrier| |**LELBX**||One handle per unit, rocker,<br>accidental-off protected||||**-F**|240V 50/60Hz| |||||||**-G**|Handle guard, (available in ZX, BX and<br>snap-in versions only)| |**LMLBX**||One handle per unit, rocker,<br>mid-trip indication, accidental-off<br>protected|||||| |||||||**-K**|1/4- 20 Stud (M6 Stud when -A<br>option is selected) ( 50A requires -K,<br>>50A do not use -K)| |Note: Other options available, consult factory.|||||||| |**Second Decision**<br>Single pole<br>Two pole<br>Three pole<br>**1**<br>**11**<br>**111**<br>2<br>Poles<br>**Third Decision**<br>3<br>* Used only with mid-trip.<br>**-1**<br>**-1REC4**<br>**-1REC5**<br>**-1REG4**<br>**-1RS4**<br>**-1RLS4**<br>Series<br>Series with auxiliary switch<br>.110 quick connect<br>Series with auxiliary switch<br>.187 quick connect<br>Series with auxiliary switch<br>(gold contacts)<br>.110 quick connect<br>Series with alarm switch,<br>electrical trip,<br>.110 quick connect<br>Series with alarm switch,<br>electrical trip,<br>.110 quick connect*<br>Internal Confguration||||||**-L**|Handle Lock| |||||||**-M**|Handle in opposite pole| |||||||**-P**|Snap-in mounting plate adapter| |||||||**-U**|120/240Vac, 5000 A.I.C., 70A max.<br>2 pole only with barrier (VDE 250Vac)| |||||||**-V**|125VDC| |||||||**-X**|Handle guard with no actuate<br>"off" feature (see detail C)| |||||||**-1**|Silver 5/16" (.312") bullet| |||||||**-2**|Gold 5/16" (.312") bullet| |||||||Notes:<br>1. One or more descriptions may be used as required.<br>2. When this decision is not used, decision 7 may be<br>substituted and U.S. thread will be supplied.<br>3.If (M5 or M6) studs are required, use “A” only on an LELK.|| |||||||**Seventh Decision**<br>7|| |**-1**||Series||||7|| |**-1REC4**||Series with auxiliary switch<br>.110 quick connect||**V**= VDE and CCC Approved||LEL Toggle Handle Color Selection|| |||||The shaded areas denote VDE and CCC (if applicable)<br>Approval options. This approval requires the addition of<br>a V at the end of the part number. The V will be added to<br>any part number formed entirely from shaded decisions.<br>If non-shaded areas are selected, the unit will not be<br>VDE or CCC Approved, but other approvals still apply.||**-01**|Black w/ white markings| |**-1REC5**||Series with auxiliary switch<br>.187 quick connect|||||| |||||||**-11**|Yellow w/ black markings| |**-1REG4**||Series with auxiliary switch<br>(gold contacts)<br>.110 quick connect|||||| |||||||**-21**|Red w/ white markings| |||||||**-31**|Blue w/ white markings| |**-1RS4**||Series with alarm switch,<br>electrical trip,<br>.110 quick connect|||||| |||||||**-41**|Green w/ white markings| |||||||**-61**|Orange w/ black markings| |||||**C**= CCC Approved|||| |**-1RLS4**||Series with alarm switch,<br>electrical trip,<br>.110 quick connect*|||||| |||||||**-91**|White w/ black markings| |||||The approval requires the addition of a C at the end<br>of the part number. The unit will not be VDE Approved.|||| |||||||See alternate 7th Decision for ZX and BX Rocker<br>Handles.|| |* Used only with mid-trip.|||||||| Notes: The LEL family of circuit breakers are designed to meet 8mm creepage and clearance requirements for installation Category 111, pollution degree 3, Case A as measured in IEC 664. Intended for use in equipment designed to comply with IEC 380, 435, 601 AND VDE 0730, 0804 & 0805. **14967** _LEL Series - Decision Tables_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## 7 **Seventh Decision** Rocker Handle Color, Indicator Color and Marking Selection (See Notes) LELZX & LMLZX Rocker Handle (Single Rocker Color) |Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)| |---|---|---|---|---|---|---|---|---|---|---|---|---| |LELZX & LMLZX Rocker Handle (Single Rocker Color)||||||||||||| ||||||Vertical Mounting<br>H||||orizontal Mounting|||| |Rocker<br>Handle<br>Color|Indicating<br>Color|Marking<br>Color|Indicates:|Unmarked|On-Off<br>Fig.1|I-O<br>Fig.2|On-Off<br>I-O<br>Fig.3<br>O<br>Fi||I-O<br>Fig.5<br>n-Off<br>g.4||On-Off<br>I-O<br>Fig.6|Marking<br>Detail| |Black|N/A|White|N/A|**-00**|**-01**|**-02**|**-0**|**3**<br>**-0**|**4**<br>**-05**||**-06**|A| |Red|N/A|White|N/A|**-20**|**-21**|**-22**|**-2**|**3**<br>**-2**|**4**|**-25**|**-26**|| |Grey|N/A|Black|N/A|**-40**|**-41**|**-42**|**-4**|**3**<br>**-4**|**4**|**-45**|**-46**|| |Orange|N/A|Black|N/A|**-50**|**-51**|**-52**|**-5**|**3**<br>**-5**|**4**|**-55**|**-56**|| |White|N/A|Black|N/A|**-90**|**-91**|**-92**|**-9**|**3**<br>**-9**|**4**|**-95**|**-96**|| |LELZX & LMLZXRocker Handle (Dual Rocker Color)||||||||||||| |Black|White|White|On|**-A0**|**-A1**|**-A2**|**-**|**A3**<br>**-A**|**4**<br>**-A5**||**-A6**|A| |Black|Red|White|On|**-B0**|**-B1**|**-B2**|**-B**|**3**<br>**-B**|**4**<br>**-B5**||**-B6**|| |Black|Green|White|On|**-C0**|**-C1**|**-C2**|**-C**|**3**<br>**-C**|**4**<br>**-C5**||**-C6**|| |Black|White|White|Off|**-F0**|**-F1**|**-F2**|**-F**|**3**<br>**-F**|**4**<br>**-F5**||**-F6**|| |Black|Red|White|Off|**-G0**|**-G1**|**-G2**|**-G3**<br>**-G**||**4**<br>**-G5**||**-G6**|| |Black|Green|White|Off|**-H0**|**-H1**|**-H2**|**-**|**H3**<br>**-H**|**4**<br>**-H5**||**-H6**|| |Black|White|White|On|**-J0**|**-J1**|**-J2**|**-J**|**3**<br>**-J**|**4**<br>**-J5**||**-J6**|B| |Black|Red|White|On|**-K0**|**-K1**|**-K2**|**-K**|**3**<br>**-K**|**4**<br>**-K5**||**-K6**|| |Black|Green|White|On|**-L0**|**-L1**|**-L2**|**-L**|**3**<br>**-L**|**4**<br>**-L5**||**-L6**|| |LELB|X Rocker Handle|(Dual Rocker Col|or)|||||||||| |Black|White|White|Off|**-M0**|**N/A**|**-M2**|**-**|**M3**<br>**N/**|**A**<br>**-M5**||**-M6**|C| |Black|Red|Red|Off|**-N0**|**N/A**|**-N2**|**-**|**N3**<br>**N/**|**A**<br>**-N5**||**-N6**|| |Black|Green|Green|Off|**-P0**|**N/A**|**-P2**|**-P**|**3**<br>**N/**|**A**<br>**-P5**||**-P6**|| |Black|Yellow|Yellow|Off|**-R0**|**N/A**|**-R2**|**-R**|**3**<br>**N/**|**A**<br>**-R5**||**-R6**|| |Notes: A. Bezels of IALBX, IULBX, IELB, IELBX are black.<br>B. Consult factory for other marking options.||||||||||||| Notes: A. Bezels of IALBX, IULBX, IELB, IELBX are black. B. Consult factory for other marking options. **==> picture [501 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> LINE<br>ROCKER HANDLECOLOR INDICATING COLOR INDICATING COLOR<br>INDICATINGCOLOR ROCKER HANDLECOLOR ROCKER HANDLECOLOR<br>LINE NO<br>Mounting/Indicator Code: A, B, CLINE INDICATION “ON” LINEMounting/Indicator Code: F, G, HINDICATION “OFF” Mounting/Indicator Code: J, K, LINDICATION “ON” Mounting/Indicator Code: M, N, P, RINDICATION “OFF”Mounting/Indicator Code: M, N, P, RINDICATION “OFF” POSITION “OFF”WITH GUARDHANDLE ACTUATIONOPTIONALACCESS POSITION “ON”WITH GUARDHANDLE<br>LOAD ON ON LINE LOAD LINE LOAD LINE LOAD LINE OFF O OFFO LOAD LINE LOAD LINE LOAD LINE LOAD ON LOADLINE LOAD ON LINE LOAD<br>LINE OFF O OFFO OFF ON O OFFO ON LOAD ON ON ON OFF ON OFF LINE O OFFO LINE OFFO OON OFFO OFFO ON<br>FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 Area reserved for FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 2 FIG. 3 FIG. 6FIG. 2 FIG. 3 FIG. 6<br>amperage marking.<br>MARKING DETAIL “A” (SEE TABLE) MARKING DETAIL “B” (SEE TABLE) MARKING DETAIL “C” (SEE TABLE)MARKING DETAIL “C” (SEE TABLE)<br>ONI<br>OFFO<br>I<br>O<br>OOFF I<br>OFF<br>ON<br>ON<br>O O<br>**----- End of picture text -----**<br> _**IAL/CEL/LEL Series - Operating Characteristics** LEL Series - Decision Tables_ **15068** _http://airpax.sensata.com/_ **==> picture [612 x 60] intentionally omitted <==** ## **CEL DECISION TABLES** **==> picture [522 x 582] intentionally omitted <==** **----- Start of picture text -----**<br> 1 First Decision 5 Fifth Decision<br>Select Type and Terminal Rated Current<br>Type Description Terminal<br>Use three numbers in build (.050 or 1.50 or 100).<br>CEL One handle per unit, UL489A Listed Standard screw terminal,<br>CELH One handle per pole, UL489A Listed no designation required Required value between and 125 amps maximum. .050 amps minimum<br>K Stud terminals<br>CML Single pole only, one handle per unit<br>mid-trip construction, UL489A Listed C Clip terminals<br>CMLH One handle per pole B Bullet terminals 6 Sixth Decision<br>mid-trip construction, UL489A Listed Optional<br>CELZX One handle per unit, rocker handle, -A Metric thread mounting inserts and<br>UL489A Listed<br>terminals<br>CMLZX Single pole only, one handle per unit, -B Barrier<br>rocker handle w/ RLS aux switch,mid-trip construction, UL489A Listed Example: -G Snap-in mounting plate adapter with<br>handle guard (ZX, BX and snap-in only)<br>CELBX One handle per unit, flat rocker handle, CEL 1 - 1REC4 - 51 - 20.0 - A - 01 - V<br>UL489A Listed -K 1/4-20 Stud (M6 stud when metric option<br>-A selected) 50A requires -K, >50A do<br>CMLBX Single pole only, one handle per unit, 1 2 3 4 5 6 7 not use -K<br>flat rocker handle w/ RLS aux switch, -P Snap-in mounting plate adapter<br>mid-trip construction, UL489A Listed<br>-T 80VDC, 10000AIC, (required over 50A)<br>-V 125VDC<br>2 Second Decision -1 Silver 5/16” (.312”) bullet<br>Poles -2 Gold 5/16” (.312”) bullet<br>1 Single pole Notes:<br>1. One or more descriptions may be used as required.<br>11 Two pole 2. When this decision is not used, decision 7 may be<br> substituted and U.S. thread will be supplied.<br>111 Three pole<br>7 Seventh Decision<br>3 Third Decision<br>LEL Toggle Handle Color Selection<br>Internal Configuration<br>-1 Series -01 Black w/ white markings<br>-1REC4 Series with auxiliary switch -11 Yellow w/ black markings<br> .110 quick connect V = VDE and CCC Approved -21 Red w/ white markings<br>-1RLS4 ** Series with auxiliary switch<br> .110 quick connect, mid-trip only The shaded areas denote VDE and CCC -31 Blue w/ white markings<br>-1REC5 Series with auxiliary switch (if applicable) approval options. Thisapproval requires the addition of a V at -41 Green w/ white markings<br> .187 quick connect<br>the end of the part number. The V will be -61 Orange w/ black markings<br>-1RS4 ** Alarm switch, .110 quick connect added to any part number formed<br>entirely from shaded decisions. If -91 White w/ black markings<br>* Only one auxiliary switch is normally supplied on two non-shaded areas are selected, the unit<br>and three pole units switch is located in the right hand will not be VDE or CCC Approved, but See alternate 7th Decision for ZX and BX Rocker<br>pole (viewed from terminal end). Note, aux switchfollowed by “R” indicates reverse mount option other approvals still apply. Handles.<br>** Not available for 125 amp single pole<br>C = CCC Approved<br>4 Fourth Decision The approval requires the addition of a<br>C at the end of the part number. The<br>Frequency and Delay unit will not be VDE Approved.<br>-51 DC short delay<br>-52 DC long delay T = TÜV Approved<br>-53* DC motor start The approval requires the addition of a<br>-59 DC 125% instant trip T at the end of the part number. The<br>unit will only be TÜV EN60947-2<br>For addition of inertial delay, add an “F” to any approved with a single pole,<br>delay numeral. Example: -51F *Not available above 100 amps. 125 amp rating configuration.<br>**----- End of picture text -----**<br> **1496** _CEL Series - Decision Tables_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## 7 **Seventh Decision** Rocker Handle Color, Indicator Color and Marking Selection (See Notes) LELZX & LMLZX Rocker Handle (Single Rocker Color) |Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)|Rocker Handle Color, Indicator Color and Marking Selection (See Notes)| |---|---|---|---|---|---|---|---|---|---|---|---|---| |LELZX & LMLZX Rocker Handle (Single Rocker Color)||||||||||||| ||||||Vertical Mounting||||Horizo|ntal Mounting||| |Rocker<br>Handle<br>Color|Indicating<br>Color|Marking<br>Color|Indicates:|Unmarked|On-Off<br>Fig.1|I-O<br>Fig.2|On-Off<br>I-O<br>Fig.3||On-Off<br>Fig.4|I-O<br>Fig.5<br>|On-Off<br>I-O<br>Fig.6|Marking<br>Detail| |Black|N/A|White|N/A|**-00**|**-01**|**-02**|**-03**||**-04**|**-05**|**-06**|A| |Red|N/A|White|N/A|**-20**|**-21**|**-22**|**-23**||**-24**|**-25**|**-26**|| |Grey|N/A|Black|N/A|**-40**|**-41**|**-42**|**-43**||**-44**|**-45**|**-46**|| |Orange|N/A|Black|N/A|**-50**|**-51**|**-52**|**-53**||**-54**|**-55**|**-56**|| |White|N/A|Black|N/A|**-90**|**-91**|**-92**|**-93**||**-94**|**-95**|**-96**|| |LELZX & LMLZXRocker Handle (Dual Rocker Color)||||||||||||| |Black|White|White|On|**-A0**|**-A1**|**-A2**|**-A3**||**-A4**|**-A5**|**-A6**|A| |Black|Red|White|On|**-B0**|**-B1**|**-B2**|**-B3**||**-B4**|**-B5**|**-B6**|| |Black|Green|White|On|**-C0**|**-C1**|**-C2**|**-C3**||**-C4**|**-C5**|**-C6**|| |Black|White|White|Off|**-F0**|**-F1**|**-F2**|**-F3**||**-F4**|**-F5**|**-F6**|| |Black|Red|White|Off|**-G0**|**-G1**|**-G2**|**-G3**||**-G4**|**-G5**|**-G6**|| |Black|Green|White|Off|**-H0**|**-H1**|**-H2**|**-H3**||**-H4**|**-H5**|**-H6**|| |Black|White|White|On|**-J0**|**-J1**|**-J2**|**-J3**||**-J4**|**-J5**|**-J6**|B| |Black|Red|White|On|**-K0**|**-K1**|**-K2**|**-K3**||**-K4**|**-K5**|**-K6**|| |Black|Green|White|On|**-L0**|**-L1**|**-L2**|**-L3**||**-L4**|**-L5**|**-L6**|| |LELB|X Rocker Handle|(Dual Rocker Col|or)|||||||||| |Black|White|White|Off|**-M0**|**N/A**|**-M2**|**-M3**||**N/A**|**-M5**|**-M6**|C| |Black|Red|Red|Off|**-N0**|**N/A**|**-N2**|**-N3**||**N/A**|**-N5**|**-N6**|| |Black|Green|Green|Off|**-P0**|**N/A**|**-P2**|**-P3**||**N/A**|**-P5**|**-P6**|| |Black|Yellow|Yellow|Off|**-R0**|**N/A**|**-R2**|**-R3**||**N/A**|**-R5**|**-R6**|| |Notes: A. Bezels of IALBX, IULBX, IELB, IELBX are black.<br>B. Consult factory for other marking options.||||||||||||| Notes: A. Bezels of IALBX, IULBX, IELB, IELBX are black. B. Consult factory for other marking options. **==> picture [293 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> LINE<br>ROCKER HANDLECOLOR INDICATING COLOR INDICATING COLOR<br>INDICATINGCOLOR ROCKER HANDLECOLOR ROCKER HANDLECOLOR<br>LINE LINE<br>INDICATION “ON” INDICATION “OFF” INDICATION “ON”<br>Mounting/Indicator Code: A, B, C Mounting/Indicator Code: F, G, H Mounting/Indicator Code: J, K, L<br>LOAD ON ON LINE LOAD LINE LOAD LINE LOAD LINE OFF O OFFO LOAD LINE LOAD LINE LOAD LINE<br>LINE OFF O OFFO OFF ON O OFFO ON LOAD ON ON ON OFF ON OFF<br>FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 Area reserved for FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6<br>amperage marking.<br>MARKING DETAIL “A” (SEE TABLE) MARKING DETAIL “B” (SEE TABLE)<br>ONI<br>OFFO<br>I<br>O<br>OOFF I<br>OFF<br>ON<br>ON<br>O O<br>**----- End of picture text -----**<br> **==> picture [214 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> NO<br>Mounting/Indicator Code: M, N, P, RINDICATION “OFF” LINE INDICATION “OFF” POSITION “OFF”WITH GUARDHANDLE ACTUATIONOPTIONALACCESS POSITION “ON”WITH GUARDHANDLE<br>Mounting/Indicator Code: M, N, P, R<br>LINELOAD O LINELOAD OFFONO O LINEOFFO OFFLOADONOON LINEOFFO LOADON<br>FIG. 2 FIG. 3FIG. 2 FIG. 6FIG. 3 FIG. 6<br>MARKING DETAIL “C” (SEE TABLE)MARKING DETAIL “C” (SEE TABLE)<br>**----- End of picture text -----**<br> _**IAL/CEL/LEL Series - Operating Characteristics** CEL Series - Decision Tables_ **1507** _http://airpax.sensata.com/_ **==> picture [612 x 60] intentionally omitted <==** ## **LELHP DECISION TABLES** ||||||**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**LELHPK 11 - 1REC4 - 51 - 125. - A**<br>Example:<br>1<br>2<br>3<br>4<br>5<br>6|**V**= VDE Approved|| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||||||||||||||||||||The shaded areas denote VDE approval<br>options. This approval requires the<br>addition of a V at the end of the part<br>number. The V will be added to any part<br>number formed entirely from shaded<br>decisions. If non-shaded areas are<br>selected, the unit will not be VDE<br>approved, but other approvals still apply.|| |**LELPK**||One handle per unit||||||||||||||||||| |**LMLPK**||One handle per unit, mid-trip||||||||||||||||||| |**LELZXPK**||One ZX rocker handle per unit (integral mounting)||||||||||||||||||| |**LMLZXPK**||One ZX rocker handle per unit, mid-trip (integral mounting)||||||||||||||||||| |**LELBXPK**||One BX rocker handleper unit (integral mounting)||||||||||||||||||| |**LMLBXPK**||One BX rocker handle per unit, mid-trip (integral mounting)||||||||||||||||||| |**LELHPK**||One handle per pole||||||||||||||||||| |**LMLHPK**||One handle per pole, mid-trip||||||||||||||||||| |||||||||||||||||||||| |1. One toggle handle per unit on 125A to 150A units (2-parallel pole)<br>2. 175A to 200A (3-parallel pole) requires handle in each pole, “H” se||||lection||||||||||||||||| |||||||1||2|||3||4||5|||6||| |Poles<br>**Second Decision**<br>**11**<br>Two pole (up to 150 amps)<br>**111**<br>Three pole (160 to 200 amps)<br>Internal Confguration<br>**Third Decision**<br>**-1**<br>Series<br>**-1REC4**<br>Series with auxiliary switch<br>.110 quick connect<br>**-1REG4**<br>Series, aux switch (gold contacts)<br>.110 quick connect<br>**-1RLSG4**Series, alarm aux switch (gold<br>contacts), .110 quick connect,<br>mid-trip only<br>**-1RLS4**<br>Series with alarm aux switch<br>.110 quick connect, mid-trip only<br>**-1RS4**<br>Series with alarm aux switch<br>.110 quick connect<br>**-1RS4**<br>Series with alarm aux switch<br>.187 quick connect<br>**-1RS5**<br>Series with alarm aux switch<br>.187 quick connect, mid-trip<br>**-1REC5**<br>Series with aux switch<br>.187 quick connect<br>**-1RLS5**<br>Series with alarm aux switch<br>.187 quick connect, mid-trip only||||||||||||||||||||| |||||**Fourth Decision**||||||**Fifth Decision**||||||||||| |||||Frequency and Delay||||||||||||||||| ||||**-51**|DC 125% short delay (125 to 150 amp)||||**125.**||||||||||||| |||||DC 135% short delay (160 to 200 amp)||||**130.**||||||||||||| |**-1**|Series|||||||||||||||||||| ||||**-52**|DC 125% long delay (125 to 150 amp)||||**135.**||||||||||||| |**-1REC4**|Series with auxiliary switch<br>.110 quick connect|||||||||||||||||||| |||||DC 135% long delay (160 to 200 amp)||||**150.**||||||||||||| |**-1REG4**|Series, aux switch (gold contacts)<br>.110 quick connect||**-59**|DC 125% instant trip (125 to 150 amp)||||**175.**||||||||||||| |||||DC 135% instant trip (160 to 200 amp)||||**200.**||||||||||||| |**-1RLS4**|Series with alarm aux switch<br>.110 quick connect, mid-trip only|||||||||||||||||||| ||||For addition of intertial delay, add an “F” to any<br>delay option. Example: - 59 becomes -59F|||||Additional ratings available.||||||||||||| |**-1RLSG4**|Series, alarm aux switch (gold<br>contacts), .110 quick connect,<br>mid-trip only|||||||||||||||||||| |**-1RS4**|Series with alarm aux switch<br>.110 quick connect|||||||||||||||||||| |**-1REC5**|Series with aux switch<br>.187 quick connect|||||||||||||||||||| |**-1RLS5**|Series with alarm aux switch<br>.187 quick connect, mid-trip only|||||||||||||||||||| |**-1RS4**|Series with alarm aux switch<br>.187 quick connect|||||||||||||||||||| |**-1RS5**|Series with alarm aux switch<br>.187 quick connect, mid-trip|||||||||||||||||||| **V** = VDE Approved The shaded areas denote VDE approval options. This approval requires the addition of a V at the end of the part number. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be VDE approved, but other approvals still apply. **==> picture [185 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> LELHPK 11 - 1REC4 - 51 - 125. - A - 01 - V<br>**----- End of picture text -----**<br> **==> picture [105 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> 7<br>7 Seventh Decision<br>Toggle Handle Color<br>-01 Black w/ white markings<br>-11 Yellow w/ black markings<br>-21 Red w/ white markings<br>-31 Blue w/ white markings<br>-41 Green w/ white markings<br>-61 Orange w/ black markings<br>-91 White w/ black markings<br>See LEL alternative 7th decision for<br>ZX & BX rocker handles<br>**----- End of picture text -----**<br> **14971** _LELHP Series - Decision Tables_ _**IAL/CEL/LEL Series - Operating Characteristics**_ _http://airpax.sensata.com/_ http://airpax.sensata.com ## **CELHP DECISION TABLES** **==> picture [268 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> First Decision<br>Select Type Terminal<br>CELP One toggle handle per unit Standard screw terminal,<br>no designation required<br>CELHP One toggle handle per pole<br>K Stud terminals<br>CMLHP One toggle handle per pole,<br>mid-trip construction C Clip terminals<br>B Bullet terminals<br>CELZXP One rocker handle per unit<br>CELBXP One flat rocker handle per unit<br>**----- End of picture text -----**<br> Example: **==> picture [107 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> V = VDE Approved<br>**----- End of picture text -----**<br> The shaded areas denote VDE approval options. This approval requires the addition of a V at the end of the part number. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be VDE approved, but other approvals still apply. 1. One toggle handle per unit is available only on 101A to 200A (two parallel pole construction) **==> picture [188 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> CELHPK 11 - 1REC4 - 51 - 125. - A - 01 - V<br>**----- End of picture text -----**<br> 2. 201A to 250A (three parallel pole constructions) require handles in each pole, “H” version |frst decision|frst decision|frst decision|frst decision|frst decision|||||**-**|**-**|**-**|**-**|**-**|**-**|**-**|**-**|**-**|**-**|**. -**|**. -**|||**-**|**-**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |3. Unit supplied with bullet terminals will not have buss bar installed, unless requested, buss bar<br>supplied standard to 150A only.<br>4. One handle per unit is available for 100A to 200A (two parallel pole constructions) and<br>201A to 250A (three pole constructions) (ZX & BX versions only)<br>5. 400 amps available with toggle handes only|||||1|||||||||||||||||||| |||||||1|||2|||3|||4|||5|||6||7|| |||||||||||||||||||||||||| |Poles<br>**Second Decision**<br>**11**<br>Two pole (up to 150 amps)<br>**111**<br>Three pole (160 to 250 amps)<br>**1111**<br>Four pole (400 amps)<br>Internal Confguration<br>**Third Decision**<br>**-0**<br>Switch only<br>**-1**<br>Series<br>**-1REC4**<br>Series with auxiliary switch<br>.110 quick connect<br>**-1RLS4 ***Series with alarm aux. switch<br>.110 quick connect, mid-trip only<br>**-1RS4 ***<br>Series with alarm aux. switch<br>.110 quick connect<br>**-1RS4 ***<br>Series with alarm aux. switch<br>.187 quick connect<br>**-1REC5**<br>Series with auxiliary switch<br>.187 quick connect<br>**-1RLS5 ***Series with alarm aux. switch<br>.187 quick connect, mid-trip only<br>1. Only one auxiliary switch is normally supplied<br>on two and three pole units. Switch is located in<br>the right hand pole (viewed from terminal end<br>panel mount position).<br>2. When more than one aux. switch is required,<br>change the 1 (of the 1REC4) to 2 or 3. If switches<br>are mixed, then use “2R” or 3R”.<br>*||||||||||||||||||||||||| |||||**Fourth Decision**|||||||**Fifth Decision**||||||||||||**7**|| |||||Frequency and Delay|||||Rated Current (Amps)||||||||||||||Toggle Handle Color|| ||||**-51**|DC 125% short delay (101 to 150 amp)|||||**125.**||||||||||||||**-01**|Black w/ white markings| |**-0**|Switch only|||DC 135% short delay (160 to 250 amp)|||||**130.**||||||||||||||**-11**|Yellow w/ black markings| |**-1**|Series||**-52**|DC 125% long delay (101 to 150 amp)|||||**135.**||||||||||||||**-21**|Red w/ white markings| |**-1REC4**|Series with auxiliary switch<br>.110 quick connect|||DC 135% long delay (160 to 250 amp)|||||**150.**||||||||||||||**-31**|Blue w/ white markings| ||||**-53**|DC 125% motor start (101 to 150 amp)|||||**175.**||||||||||||||**-41**|Green w/ white markings| |**-1RLS4 ***|Series with alarm aux. switch<br>.110 quick connect, mid-trip only|||||||||||||||||||||||| |||||DC 135% motor start (160 to 250 amp)|||||**200.**||||||||||||||**-61**|Orange w/ black markings| |**-1RS4 ***|Series with alarm aux. switch<br>.110 quick connect||**-59**|DC 125% instant trip (101 to 150 amp)|||||**400.**||||||||||||||**-91**|White w/ black markings| |||||DC 135% instant trip (160 to 250 amp)|||||Additional ratings available.||||||||||||||See LEL alternative 7th decision for<br>ZX & BX rocker handles|| |**-1REC5**|Series with auxiliary switch<br>.187 quick connect|||||||||||||||||||||||| |||||||||||||||||||||||||| ||||**6**|**Sixth Decision**||||||||||||||||||||| |**-1RLS5 ***|Series with alarm aux. switch<br>.187 quick connect, mid-trip only|||Optional (leave entry blank if none apply)||||||||||||||||||||| ||||**-A**|Metric thread mounting inserts and terminals||||||||||||||||||||| |**-1RS4 ***|Series with alarm aux. switch<br>.187 quick connect|||||||||||||||||||||||| ||||**-B**|Barrier||||||||||||||||||||| ||||**-G**|Snap-in mounting plate adapter with handle guard (ZX, BX & snap-in only)||||||||||||||||||||| |1. Only one auxiliary switch is normally supplied<br>on two and three pole units. Switch is located in<br>the right hand pole (viewed from terminal end<br>panel mount position).<br>2. When more than one aux. switch is required,<br>change the 1 (of the 1REC4) to 2 or 3. If switches<br>are mixed, then use “2R” or 3R”.<br>*||||||||||||||||||||||||| ||||**-X**|Handle guard with no actuate off feature (BX only, no mid-trip)||||||||||||||||||||| ||||**-1**|Silver 5/16” (.312”) bullet||||||||||||||||||||| ||||**-2**|Gold 5/16” (.312”) bullet||||||||||||||||||||| ||||Note<br>1. On|s:<br>e or more descriptions may be used as required.||||||||||||||||||||| |Not available at 400 amps|||2 When this decision is not used decision 7 may be substituted and U S thread will be supplied|||||||||||||||||||||| - Not available at 400 amps - 2 When this decision is not used decision 7 may be substituted and U S thread will be supplied _**IAL/CEL/LEL Series - Operating Characteristics** LELHP Series - Decision Tables_ **15072** _http://airpax.sensata.com/_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →