IT 65-S ULTRASTAB
Current Transducer, IT xx5 Series, 60 A, 0.03 %, Photocoupler Output, -14.25 VDC to 15.75 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Photocoupler; Supply Voltage DC Min:-14.25V; Supply Voltage DC Max:15.75V; Current Measuring Range DC:-60A to 6; Available until stocks are exhausted Alternative available
- SVHC: No SVHC (17-Jan-2022)
- Accuracy: -
- Accuracy %: 0.03%
- Product Range: IT xx5 Series
- Response Time: 1µs
- Primary Current: 60A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Photocoupler
- Supply Voltage Range: ± 14.25V to ± 15.75V
- Supply Voltage DC Max: 15.75V
- Supply Voltage DC Min: -14.25V
- Current Sensor Technology: Closed Loop
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -85A to 85A
- Current Measuring Range DC: -60A to 60A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 555.98 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Current transducer IT 65-S ULTRASTAB** _I_ **= 60 A** P N **For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.** ## **Features** - ●Wide operating temperature range of ‒40 °C to 85 °C - ●Closed loop (compensated) current transducer using an extremely accurate zero flux detector - ●Electrostatic shield between primary and secondary circuit - ●9-pin D-Sub male secondary connector - ●Optically insulated output (photocoupler type) indicates transducer state - ●LED indicator confirms normal operation. ## **Advantages** - ●Very high accuracy - ●Excellent linearity - ●Extremely low temperature drift - ●Wide frequency bandwidth - ●High immunity to external fields - ●No insertion losses - ●Low noise on output signal ## **Applications** - ●Feed back element in high performance gradient amplifiers for MRI - ●Feedback element in high-precision, high-stability power supplies - ●Calibration unit - ●Energy measurement - ●Medical equipment. ## **Standards** - ●EN 61000-6-2: 2005 - ●EN 61000-6-3: 2007 - ●EN 61010-1: 2010. ## **Application Domains** - ●Industrial - ●Laboratory - ●Medical. - ●Low noise feedback to primary conductor. N° 88.K7.27.000.0 Page 1/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 28September2020/Version 2 **IT 65-S ULTRASTAB** ## **Insulation coordination** **==> picture [454 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Value Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Value**|**Comment**| |---|---|---|---|---| |||||| |Rated insulation RMS voltage, basic insulation|_U_Nm|V|2000|IEC 61010-1 conditions<br>- over voltage cat III<br>- pollution degree 2| |Rated insulation RMS voltage, reinforced insulation|_U_Nm|V|600|| |Rated insulation RMS voltage, basic insulation|_U_Nm|V|1000|EN 50178 conditions<br>- over voltage cat III<br>- pollution degree 2| |Rated insulation RMS voltage, reinforced insulation|_U_Nm|V|600|| |RMS voltage for AC insulation test, 50/60 Hz, 1 min|_U_d|kV|5.4|Between primary and<br>secondary + shield| |||V DC|200|Between secondary and<br>shield| |||V DC|300|Between secondary and<br>status output| |Impulse withstand voltage 1.2/50 µs|_U_Ni|kV|9.9|| |Clearance (pri. - sec.)|_d_CI|mm|11|Shortest distance<br>through air| |Creepage distance (pri. - sec.)|_d_Cp|mm|11|Shortest path along<br>device body| |Comparative tracking index|_CTI_||600|| If insulated cable is used for the primary circuit, the voltage category could be improved with the following table (for single insulation) (IEC 61010-1 standard): Cable insulated (primary) Category HAR03 2150 V CAT III HAR05 2250 V CAT III HAR07 2350 V CAT III ## **Environmental and mechanical characteristics** **==> picture [512 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Min Typ Max Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |||||||| |Ambient operating temperature|_T_A|°C|‒40||85|| |Ambient storage temperature|_T_A st|°C|‒40||85|| |Relative humidity|_RH_|%|20||80|Non-condensing| |Dimensions||||||See drawing on page 7| |Mass|_m_|kg||0.33||| Page 2/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 28September2020/Version 2 **IT 65-S ULTRASTAB** ## **Electrical data** ## At _T_ A = 25 °C, ± _U_ C = ±15 V, unless otherwise noted. Lines with a * in the comment column apply over the −40 … 85 °C ambient temperature range. **==> picture [512 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Min Typ Max Conditions<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Conditions**|**Conditions**| |---|---|---|---|---|---|---|---| ||||||||| |Primary continuous direct current (nominal)|_I_P N DC|A|−60||60|*|| |Primary nominal RMS current|_I_P N|A|||60|*|| |Primary current, measuring range|_I_P M|A|−85||85|*|Peak limit| |Measuring resistance over operating current<br>temperature and supply voltage range|_R_M|Ω|0||50||See graph on page 5| |Secondary current|_I_S|mA|−142||142|*|Peak limit| |Secondary nominal RMS current|_I_S N|mA|||100|*|| |Turns ratio|_N_P/_N_S|||1:600||*|| |Resistance of secondary winding|_R_S|Ω||28|||| |Maximum withstand primary peak current1)|_Î_P max|A|−300||300||@ pulse of 100 ms| |Supply voltage DC|_U_C|V|±14.25|±15|±15.75|*|| |Current consumption|_I_C|mA||65|71||Add_I_Sfor total current<br>consumption| |||||70|78|*|| |RMS noise current 0 ... 10 Hz2)|_I_no|ppm|||0.5||| |RMS noise current 0 ... 100 Hz2)|||||0.75||| |RMS noise current 0 ... 1 kHz2)|||||2||| |RMS noise current 0 ... 10 kHz2)|||||6||| |RMS noise current 0 ... 50 kHz2)|||||15||| |Re-injected RMS noise on primary bus bar||µV|||30||0 ... 50 kHz| |Electrical ofset current + self magnetization +<br>efect of earth magnetic feld2)|_I_O E|ppm||±225|±300||| |||||±330|±400|*|| |Ofset stability2)||ppm/month|||2.5||| |Linearity error2)|_ε_L|ppm||±1|±3||@ ±_I_P N DCrange| |||||±3|±9|*|| |Delay time to 90 % of the final output value for_I_P N DCstep<br>3)|_t_D 90|µs|||1||d_i/_d_t_of 100 A/µs| |Frequency bandwidth (±1 dB)|_BW_|kHz||600|||Small-signal bandwidth,<br>0.5 % of_I_P N DC| |Frequency bandwidth (±3 dB)|_BW_|kHz||800|||Small-signal bandwidth,<br>0.5 % of_I_P N DC| Notes:[1)] Single pulse only, not AC. The transducer may require a few seconds to return to normal operation when autoreset system is running. - 2) All ppm figures refer to full-scale which corresponds to a secondary current ( _I_ S) of 100 mA. - 3) For a d _i /_ d _t_ = 100 A/µs, accurately followed. Page 3/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 28September2020/Version 2 **IT 65-S ULTRASTAB** ## **Overload protection - Electrical specification - Status** The overload occurs when the primary current _I_ P exceeds a trip level such that the fluxgate detector becomes completely saturated and, consequently, the transducer will switch from normal operation to overload mode. This trip level is guaranteed to be greater than 110 % of _I_ P M and its actual value depends on operating conditions such as temperature and measuring resistance. When this happens, the transducer will automatically begin to sweep in order to lock on the primary current again. ## Overload condition should read: - ●The secondary current _I_ S generated is a low frequency signal between ‒142 mA and 142 mA. - ●The signal _U_ out (operation status between pin 3 and 8 of the D-sub connector) switches to _U_ + or GND depending on how it is wired. In other words, the output transistor is switched off (i.e., no current from collector to emitter). See the status port wiring below. - ●The green LED indicator (normal operation status) turns off. The measuring can resume when the primary current returns in the nominal range between − _I_ P M and + _I_ P M. Then the signal _U_ out switches to _U_ + or GND and the green LED indicator (normal operation status) is again lit. ## **TO ENSURE A SAFE RECOVERY FROM SATURATION, THE MAXIMUM BURDEN RESISTOR ALLOWED IS 43 Ω.** ## **Status/Interlock port wiring** **==> picture [352 x 377] intentionally omitted <==** **----- Start of picture text -----**<br> Diagram A: Active Low Output U+ : 4 .. +45V<br>DC<br>Power<br>Supply<br>R<br>I C E max : 30 mA D-Sub9<br>I C E min : 2 mA Pin<br>8 U OUT<br>The photocoupler is driven as follows: Collector<br>ON : Transducer is OK (Normal Operation)<br>D-Sub9<br>OFF : Transducer is not OK Pin U+ (V) - 0.65 V<br>Emitter 3 R min (kΩ) = 30 mA<br>U+ (V) - 0.65 V<br>R max (kΩ) = 2 mA<br>TRANSDUCER USER SIDE<br>Diagram B: Active High Output U+ : 4 .. +45V<br>DC<br>D-Sub9 Power<br>Pin Supply<br>8<br>The photocoupler is driven as follows: Collector<br>ON : Transducer is OK (Normal Operation)<br>D-Sub9<br>OFF : Transducer is not OK Pin<br>Emitter<br>3 U OUT<br>I C E max : 30 mA<br>I C E min : 2 mA R R min (kΩ) = U+ (30 mAV) - 0.65 V<br>U+ (V) - 0.65 V<br>R max (kΩ) = 2 mA<br>TRANSDUCER USER SIDE<br>**----- End of picture text -----**<br> LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 4/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com 28September2020/Version 2 **IT 65-S ULTRASTAB** The following table shows how the output signal _U_ out acts depending on how it is wired: |**Case**|_U_**out**|**Description**| |---|---|---| |Diagram A|< 0.2 V|The transducer is OK (Normal operation)| ||_U+_|The transducer is not OK (Overload mode or supply fault)| |Diagram B|< 0.2 V|The transducer is not OK (Overload mode or supply fault)| ||_U+_|The transducer is OK (Normal operation)| ## Some recommended standard values of _R_ : |**Power supply voltage**_U_**+**|**_R_min (k**Ω**)**|**_R_max (k**Ω**)**|**_R _standard values ±5 %**| |---|---|---|---| |5 V|0.145|2.175|0.150 kΩ, 2 kΩ| |12 V|0.378|5.675|0.390 kΩ, 5.6 kΩ| |24 V|0.778|11.675|0.820 kΩ, 11 kΩ| ## **Electrical data - status port** |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |Collector-emitter voltage, off-state|_U_C E off|V|4||45|| |Maximum collector-emitter current, on-state|_I_C E max|mA|2||30|| |Maximum reverse collector-emitter voltage, off-state|_U_C E R off max|V|||5|| |Collector-emitter voltage, on-state|_U_C E on|V|||0.2|| ## **Maximum measuring resistor versus primary current and temperature** **==> picture [240 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> = ee en i a a<br>1 my a<br>te a!<br>i Pn en Ces<br>‘ 1<br>60 Si a|<br>1 me fey!<br>PO beoneeeboneeeedecceecth1 1 he ; ! me<br>eee e aang EtGfee<br>1 Tay<br>BU ee!<br>P=----; ; et<br>} }<br>BO povsoonpossceegecesceapecsecpecsscteccseny<br>042<br>Primary current I P (A RMS)<br>(Ω)<br>M<br>R<br>Maximum<br>**----- End of picture text -----**<br> LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 5/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com 28September2020/Version 2 **IT 65-S ULTRASTAB** ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. ## Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary connection, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 6/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 28September2020/Version 2 **IT 65-S ULTRASTAB** ## **Dimensions** (in mm) **==> picture [510 x 340] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P<br>+ U C<br>− U C I S<br>d Cl d Cp<br>**----- End of picture text -----**<br> ## **Conn** ~~**e**~~ **ction** ## **Me** ~~**cha**~~ **nic** ~~**a**~~ **l ch** ~~**ar**~~ **ac** ~~**ter**~~ **istics** ●Normal operation status (Pins 3 and 8) Normal operation means: - ±15 V (± _U_ C) present - zero detector is working - compensation current < 110 % of _I_ ~~P M green LED indicator is lit.~~ ## **Remarks** - _I_ S is positive when _I_ P flows in the direction of the arrow. - ●We recommend that a shielded output cable and plug are used to ensure the maximum immunity against electrostatic fields. - ~~G~~ e ~~ne~~ ral t ~~ol~~ eranc ~~e~~ - ±0.3 mm - ●Transducer fastening - Straight mounting - 2 holes ⌀ 5.5 mm 2 M5 steel screws 3.7 N ⋅ m - R ~~e~~ commended fastening torque 3.7 N ⋅ m ~~- Flat mounting 4 holes ⌀ 4.5 mm~~ 4 M4 steel screws Recommended fastening torque - Recommended fastening torque 2.8 N ⋅ m - ●Connection of secondary on D-SUB-9, connector UNC 4-40 - ●Primary through hole ⌀ < 26 mm - ●Pin 4 should be connected to cable and connector shield to maintain lowest output noise. - ●All mounting recommendations are given for a standard mounting. Screws with flat and spring washers. - ●Temperature of the primary conductor should not exceed 100 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **Products/Product Documentation.** Page 7/7 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 28September2020/Version 2
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →