IT 605-S ULTRASTAB
Current Transducer, IT xx5 Series, 600A, 0.0032 %, Photocoupler Output, -14.25 Vdc to 15.75 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Accuracy %: 0.0032%
- Product Range: IT xx5 Series
- Response Time: 1µs
- Sensor Output: Photocoupler
- Supply Voltage DC Max: 15.75V
- Supply Voltage DC Min: -14.25V
- Current Measuring Range AC: -849A to 849A
- Current Measuring Range DC: -600A to 600A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 809.13 € |
| Current stock | 10+ |
| Lead time | 30 days |
_I_ **= 600 A PN**
## **Current Transducer IT 605-S ULTRASTAB**
**For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary.**
## **Features**
- ●Wide operating temperature range of −40 °C to 85 °C
- ●Closed loop (compensated) current transducer using an
- extremely accurate zero flux detector
- ●Electrostatic shield between primary and secondary circuit
- ●9-pin D-Sub male secondary connector
- ●Optically insulated output (photocoupler type) indicates transducer state
- ●LED indicator confirms normal operation.
## **Advantages**
- ●Very high accuracy
- ●Excellent linearity
- ●Extremely low temperature drift
- ●Wide frequency bandwidth
- ●High immunity to external fields
- ●No insertion losses
- ●Low noise on output signal
## **Applications**
- ●Feed back element in high performance gradient amplifiers for MRI
- ●Feedback element in high-precision, high-stability power supplies
- ●Calibration unit
- ●Energy measurement
- ●Medical equipment.
## **Standards**
- ●EN 61000-6-2: 2005
- ●EN 61000-6-3: 2007
- ●EN 61010-1: 2010.
## **Application Domains**
- ●Industrial
- ●Laboratory
- ●Medical.
- ●Low noise feedback to primary conductor.
Page 1/6
N° 88.K7.52.000.0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
16April2015/version 1
www.lem.com
**IT 605-S ULTRASTAB**
## **Insulation coordination**
**==> picture [512 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Parameter Symbol Unit Value Comment<br>**----- End of picture text -----**<br>
|**Parameter**|**Symbol**|**Unit**|**Value**|**Comment**|
|---|---|---|---|---|
||||||
|Rated insulation rms voltage, basic insulation|_U_b|V|1600|IEC 61010-1 conditions<br>- over voltage cat III<br>- pollution degree 2|
|Rated insulation rms voltage, reinforced insulation|_U_b|V|300|IEC 61010-1 conditions<br>- over voltage cat III<br>- pollution degree 2|
|Rated insulation rms voltage, basic insulation|_U_b|V|1000|EN 50178 conditions<br>- over voltage cat III<br>- pollution degree 2|
|Rated insulation rms voltage, reinforced insulation|_U_b|V|600|EN 50178 conditions<br>- over voltage cat III<br>- pollution degree 2|
|Rms voltage for AC insulation test, 50/60 Hz, 1 min|_U_d|kV|4.6|Between primary and<br>secondary + shield|
|Insulation voltage between secondary and shield||V DC|200|Between secondary and<br>shield|
|Insulation voltage between secondary status output||V DC|500|Between secondary and<br>status output|
|Impulse withstand voltage 1.2/50 µs|_Û_W|kV|8.5||
|Clearance (pri. - sec.)|_d_CI|mm|9|Shortest distance through<br>air|
|Creepage distance (pri. - sec.)|_d_Cp|mm|9|Shortest path along device<br>body|
|Comparative tracking index|_CTI_||600||
If insulated cable is used for the primary circuit, the voltage category could be improved with the following table (for single insulation) (IEC 61010-1 standard):
Cable insulated (primary) Category HAR03 1750 V CAT III HAR05 1850 V CAT III HAR07 1950 V CAT III
## **Environmental and mechanical characteristics**
|**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**|
|---|---|---|---|---|---|---|
|Ambient operating temperature|_T_A|°C|−40||85||
|Ambient storage temperature|_T_S|°C|−40||85||
|Relative humidity|_RH_|%|20||80|Non-condensing|
|Dimensions||||||See drawing page 6|
|Mass|_m_|kg||1.08|||
Page 2/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
16April2015/version 1
www.lem.com
**IT 605-S ULTRASTAB**
## **Electrical data**
At _T_ A= 25 °C, ± _U_ C = ±15 V, unless otherwise noted.
Lines with a * in the comment column apply over the −40 … 85 °C ambient temperature range.
**==> picture [513 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Parameter Symbol Unit Min Typ Max Comment<br>**----- End of picture text -----**<br>
|**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**|**Comment**|
|---|---|---|---|---|---|---|---|
|||||||||
|Primary continuous direct current|_I_PN DC|A|−600||600|*||
|Primary nominal rms current|_I_PN|A|||600|*||
|Primary current, measuring range|_I_PM|A|−849||849|*|Peak limit|
|Measuring resistance over supply voltage<br>range|_R_M|Ω|0||5||See graph page 4|
|Secondary current|_I_S|mA|−566||566|*|Peak limit|
|Secondary nominal rms current|_I_SN|mA|||400|*||
|Conversion ratio|_K_N|||1:1500||*||
|Resistance of secondary winding|_R_S|Ω||11||||
|Overload capability1)|_Î_P|A|−3000||3000||@ pulse of 100 ms|
|Supply voltage DC|_U_C|V|±14.25|±15|±15.75|*||
|Current consumption|_I_C|mA||122|128||Add_I_Sfor<br>total current<br>consumption|
|||||131|139|*||
|Output rms noise current 0 … 10 Hz2)|_I_no|ppm|||0.05|||
|Output rms noise current 0 … 100 Hz2)|||||0.5|||
|Output rms noise current 0 … 1 kHz2)|||||1|||
|Output rms noise current 0 … 10 kHz2)|||||3|||
|Output rms noise current 0 … 50 kHz2)|||||6|||
|Re-injected rms noise on primary bus bar||µV|||5||0 … 50 kHz|
|Electrical offset current + self magnetization<br>+ effect of earth magnetic feld2)|_I_OE|ppm||±25|±32|||
|||||±28|±36|*||
|Offset stability2)||ppm/month|||1|||
|Linearity error2)|_ε_L|ppm||±3|±7||@ ±_I_PN DCrange|
|||||±4|±8|*||
|Step response time to 90 % of_I_PN DC|_t_r|µs|||1||d_i_/d_t_of 100 A/µs|
|d_i_/d_t_accurately followed|d_i_/d_t_|A/µs||100||||
|Frequency bandwidth (±1 dB)|_BW_|kHz||200|||Small-signal<br>bandwidth,<br>0.5 % of_I_PN DC|
|Frequency bandwidth (±3 dB)|_BW_|kHz||300|||Small-signal<br>bandwidth,<br>0.5 % of_I_PN DC|
Notes: 1) Single pulse only, not AC. The transducer may require a few seconds to return to normal operation when autoreset system is running
> 2) All ppm figures refer to full-scale which corresponds to a secondary nominal rms current ( _I_ SN) of 400 mA.
Page 3/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
16April2015/version 1
www.lem.com
**IT 605-S ULTRASTAB**
## **Overload protection - Electrical specification - Status**
The overload occurs when the primary current _I_ P exceeds a trip level such that the fluxgate detector becomes completely saturated and, consequently, the transducer will switch from normal operation to overload mode.
This trip level is guaranteed to be greater than 110 % of _I_ PM and its actual value depends on operating conditions such as temperature and measuring resistance.
When this happens, the transducer will automatically begin to sweep in order to lock on the primary current again and the measuring can resume when the primary current returns in the measuring range between − _I_ PM and + _I_ PM. In overload mode, the secondary current _I_ S generated is a low frequency signal between −0.566 A and 0.566 A.
The overload conditions will be:
- ●The potential-free contact (normal operation status) between pin 3 and 8 (of the D-sub connector) switches off, this contact becomes open.
- ●The green LED indicator (normal operation status) turns off.
Max voltage pin 3 and pin 8, off-State 100 V Max current pin 3 and pin 8, on-State 1000 mA On-State resistance pin 3 and pin 8: 30 mΩ (max)
## **Maximum measuring resistor versus primary current and temperature**
**==> picture [233 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
+. ime<br>eyre | ae arMea<br>er ea!<br>TO ree | i<br>pen nnen denn needec nee e chen Pgh neon ne Pein donee<br>Pee!<br>i ey<br>aay!<br>ae!<br>qo<br>goo 420440. sss<br>Primary current I P (A rms)<br>(Ω)<br>M<br>R<br>Maximum<br>**----- End of picture text -----**<br>
Page 4/6 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
16April2015/version 1
**IT 605-S ULTRASTAB**
## **Status/Interlock port wiring**
**==> picture [307 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
Example of application<br>Status/Interlock port wiring<br>V+<br>V+<br>DC DC<br>Power Power<br>Supply D-SUB-9 Pin Supply<br>R 3<br>D-SUB-9 Pin<br>3 V out D-SUB-9 Pin<br>8 V out<br>D-SUB-9 Pin<br>R<br>8<br>V out is Active Highis Active High<br>**----- End of picture text -----**<br>
- _**V**_ **out is Active Low** _**V**_ **out is Active Highis Active High** → _**V**_ **out** switches to GND when the transducer is OK → _**V**_ **out** switches to V+ when the transducer is OK (Normal operation). (Normal operation).
- → _**V**_ **out** switches to V+ when the transducer is not OK → _**V**_ **out** switches to GND when the transducer is not OK (Overload mode or supply fault). (Overload mode or supply fault).
## **Safety**
This transducer must be used in limited-energy secondary circuits according to IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary connection, power supply). Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 5/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
16April2015/version 1
www.lem.com
**IT 605-S ULTRASTAB**
## **Dimensions** (in mm)
**==> picture [511 x 334] intentionally omitted <==**
## ~~**Connection**~~
- ●Normal operation status (Pins 3 and 8) Normal operation means: - ±15 V (± _U_ C) present - zero detector is working - primary current ≤ 110 % of _I_ PM
- green LED indicator is lit.
|**Contact(Pins 3 and 8)**|**Description**|
|---|---|
|Closed<br>T<br>(|he transducer is OK<br>Normal operation)|
|Open<br>T<br>(|he transducer is not OK<br>Overload mode or supply fault)|
## **Remarks**
_I_ S is positive when _I_ P flows in the direction of the arrow. We recommend that a shielded output cable and plug are used to ensure the maximum immunity against electrostatic fields. Pin 4 should be connected to cable and connector shield to maintain lowest output noise.
## ~~**Mechanical characteristics**~~
- ●General tolerance ±0.3 mm
- ●Transducer fastening
- - Straight mounting 2 holes ⌀ 6.5 mm
- ● 2 × M6 steel screws
- Recommended fastening torque 4.4 N·m
- Flat mounting 4 holes ⌀ 5.5 mm 4 × M5 steel screws
- Recommended fastening torque 3.7 N·m
- ●Connection of secondary on D-SUB-9, connector UNC 4-40
- ●All mounting recommendations are given for a standard mounting. Screws with flat and spring washers.
- ⌀ ≤ 30 mm
- ●Primary through hole
- ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **Products/Product Documentation.**
Temperature of the primary conductor should not exceed 100 °C.
Page 6/6 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
16April2015/version 1
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →