- Manufacturer: DOLD
- Product type: Power Relays
- Contact Configuration:DPDT; Coil Voltage:24VDC; Contact Current:16A; Product Range:IK 8701 Series; Relay Mounting:DIN Rail; Coil Type:DC; Contact Voltage VAC:230VAC; Relay Terminals:Screw; Conta
- Coil Type: DC
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail
- Coil Resistance: -
- Contact Current: 16A
- Relay Terminals: Screw
- Contact Material: -
- Contact Voltage VAC: 230VAC
- Contact Voltage VDC: 24V
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 43.04 € |
| Current stock | 200+ |
| Lead time | 30 days |
**Installation / control technique** **Switching relay IK 8701, IL 8701, IN 8701** ~~it~~ **Input-output interface relay** **==> picture [5 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> 0222085<br>**----- End of picture text -----**<br> According to EN 61 810-1 Optionally contacts with up to a maximum of 4 changeover contacts High thermal current Ith Pushbutton for manual actuation of the contact Operating position display Optionally without manual actuation and an operating position display Optionally for 2-wire initiator activation Optionally for switching low loads Optionally for switching lamps with parallel compensation (e.g. HQ lamps) Optionally for switching large inductive direct current loads Optionally with a recovery diode Optionally with reliable release voltage of AC 120 V IK 8701: width 17,5 mm IL 8701: width 35 mm IN 8701: width 52,5 mm ## **Circuit diagrams** **==> picture [274 x 546] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||| |---|---|---|---|---|---|---|---|---| |14|14|24|14| |12| |on|pt|a| |23|24| |13|14|11|14| |13|14|12| |A1|A2|A1|A2| |A1|A2| |Shige|i,| |A1|A2|A1|A2|A1|A2| |13|13|23|11| |IK 8701.01|IK 8701.02|IK 8701.11| |14|24|14|14|34|44|13|14| |12|22|12|22|32|42| |41|44| |21|24|42| |22|31|34|13|14| |32| |1h|11|1214|21|I|2422|i|Et|Gy| |A1|A2| |11|14| |12| |A1|A2| |A1|A2| |A1|A2|A1|A2|A1|A2| |11|21|11|21|31|41| |IK 8701.12|IL 8701.14|IK 8701.01/006| |13|14|23|24|14|24| |11|12|21|22|12|22| |rook|Eee)|pty)| |23|24|21|21|24| |22|22| |13|14| |11|11|14| |12|12| |A1|A2| |A1|A2|A1|A2| |A2| |A1|A2|A1|A2|A1|+| |11|21| |IL 8701.02/006|IL 8701.06/006|IK 8701.12/008| |IK 8701.12/005| **----- End of picture text -----**<br> ## **Approvals and marking** ## **Applications** For switching lamp loads Input interface relay, e.g. for activation of PLC Output interface relay, e.g. for PLC-controlled loads ## **Function** The contacts are actuated with an armature via a plunger. After the exciting voltage has dropped, a spring returns the armature (which is connected to the plunger) to its home position. The contacts can be actuated manually via a pushbutton on the front as well. This pushbutton acts at the same time as an operating position display. The contacts are closed when the pushbutton is pressed. The red pushbutton is flush with the front edge when there is no current. ## **Indicators** Pushbutton: pressed in when the relay is supplied with current ## **Technical data** ## **Input** **Nominal voltage UN:** AC 24, 42, 230 V DC 12, 24 V other voltages available on request **Voltage range:** 0,9 ... 1,1 UN **Nominal consumption:** IK 8701: AC 1,8 W DC 1,2 W IL 8701: AC 3,8 W DC 2,6 W IN 8701: AC 5,8 W DC 4,0 W **Nominal frequency:** 50 or 60 Hz ## **Output** ## **Contacts** **==> picture [259 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |IK 8701.01:|1 NO contact| |IK 8701.02:|2 NO contacts| |IK 8701.05:|1 NC contact| |IK 8701.06:|2 NC contacts| |IK 8701.11:|1 changeover contact| |IK 8701.12:|2 changeover contacts| |IL 8701.13:|3 changeover contacts| |IL 8701.14:|4 changeover contacts| |Operate time:|< 30 ms| |Release time:|< 30 ms| |Nominal output voltage:|AC 230 / 400 V|EN 60 947-5-1| |Thermal current Ith:|16 A| |Direct current load:|See arc limit curve| **----- End of picture text -----**<br> All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. IK 8701, IL 8701, IN 8701 / 31.10.01 bzd 1 ## **Technical data** ## **Switching capacity** fluorescent lamp load: 20 lamps with 58 W / contact each duo switching (series compensated): 2 x 20 lamps with 58 W / contact each 5 x 10[4] switching cycles bulb load: 1200 W / contact 5 x 10[4] switching cycles **Electrical life:** 500 switching cycles / h with ohmic load AC 230 V: 6 A 150 x 10[4] switching cycles 10 A 75 x 10[4] switching cycles 16 A 12 x 10[4] switching cycles Inductive load cos � 0,6: 10 A 10 x 10[4] switching cycles **DC-load:** see arc limit curve **Permissible switching frequency:** 1 000 switching cycles / h **Short circuit strength max. fuse rating:** 16 A gL EN 60 947-5-1 **Mechanical life:** > 10 x 10[6] switching cycles ## **General data** **Operating mode:** Continuous operation **Temperature range:** - 20 ... + 45 � C **Clearance and creepage distances** overvoltage category / contamination level: 4 kV / 2 IEC 60 664-1 **Degree of protection:** Housing: IP 30 EN 60 529 Terminals: IP 20 EN 60 529 **Housing:** Thermoplastic with V0 behaviour according to UL subject 94 **Vibration resistance:** Amplitude 0,35 mm, frequency 10 ... 55 Hz EN 60 068-2-6 **Climate resistance:** Humid heat EN 60 068-2-30 **Terminal designation:** EN 50 005 **Wire connection:** 2 x 2,5 mm[2] solid or 2 x 1,5 mm[2] stranded ferruled DIN 46 228-1/-2/-3 or 2 x 1 mm[2] stranded ferruled DIN 46 228-4 **Wire fixing:** Flat terminals with self-lifting clamping piece EN 60 999 **Mounting:** DIN rail EN 50 022 **Weight:** IK 8701: 100 g IL 8701: 200 g IN 8701: 300 g ## **Dimensions** |**Width x height x depth**||| |---|---|---| |IK 8701:|17,5 x 89 x 58 mm|| |IL 8701:|35 x 89 x 58 mm|| |IN 8701:|52,5 x 89 x 58 mm|| |**Standard type**||| |IK 8701.12 AC 230 V 50 Hz||| |Article number:|0033896|stock item| |�Pushbutton for manual actuation of the contacts||| |and operating position display||| |�Output:|2 changeover contacts|| |�Nominal voltage UN:|AC 230 V|| |�Width:|17,5 mm|| ## **Variants** **IK 8701. _ _ /001:** For switching low loads up to a maximum of 6 VA/W at 0,3 ... 60 V / 1 ... 300 mA The contacts also permit the maximum switching current. However, since the gold plating is burnt off at this current level, the unit is no longer suitable for switching low loads again afterwards. **IK 8701. _ _ /002:** Can be activated with 2-wire initiators, permissible residual current � 3 mA. Max. 6 glow lamps (0,5 mA each) are possible parallel to the mains button. **IK 8701. _ _ /003:** 3 mm contact opening (only NC and NO contact) **IK 8701. _ _ /005:** Same as IK 8701. _ _ /001 with a recovery diode to provide protection against voltage surges **IK 8701. _ _ /006:** For switching large inductive direct current voltage loads (DC 220 V, L/R = 30 ms), (only NC and NO contact) **IK 8701. _ _ /007:** For switching lamps with parallel compensation, For switching lamps with parallel compensation, e.g. HQ lamps. (only 1 or 2 NO contacts) Maximum parallel compensation 100 µF **IK 8701. _ _ /008:** With a recovery diode to provide protection against voltage surges **IK 8701. _ _ /009:** With a reliable release voltage of AC 120 V with a nominal voltage of AC 230 V. **IK 8701. _ _ /010:** Same as IK 8701. _ _ /006 with a recovery diode to provide protection against voltage surges **IK 8701._ _/016:** Nominal voltage DC 24 V Voltage range 0,8 ... 1,15 UN Temperature range - 20 ... + 55 � C (only 1 NC, NO or changeover contact) **IK 8701. _ _ /700:** Without manual actuation and an operating position display ## **Ordering example for variants** IK 8701 .01 /_ _ _ AC 230 V 50 Hz Nominal frequency Nominal voltage Variant, if required Contacts Type ## **Characteristics** **==> picture [142 x 137] intentionally omitted <==** Arc limit curve for direct current voltage-resistive load 2 ## **Specifiaction for tender for IK 8701** Switching relay according to EN 61 810-1 to be built in consumer units, 1 NO contact, thermal current 16 A, pushbutton for manual actuation of the contacts and operating position display. Width 17,5 mm. Type IK 8701.01 Manufactured by: E. DOLD & SÖHNE KG Switching relay according to EN 61 810-1 to be built in consumer units, 2 NO contacts, thermal current 16 A, pushbutton for manual actuation of the contacts and operating position display. Width 17,5 mm. Type IK 8701.02 Manufactured by: E. DOLD & SÖHNE KG Switching relay according to EN 61 810-1 to be built in consumer units, 1 changeover contact, thermal current 16 A, pushbutton for manual actuation of the contacts and operating position display. Width 17,5 mm. Type IK 8701.11 Manufactured by: E. DOLD & SÖHNE KG Switching relay according to EN 61 810-1 to be built in consumer units, 2 changeover contacts, thermal current 16 A, pushbutton for manual actuation of the contacts and operating position display. Width 17,5 mm. Type IK 8701.12 Manufactured by: E. DOLD & SÖHNE KG Switching relay according to EN 61 810-1 to be built in consumer units, 3 changeover contacts, thermal current 16 A, pushbutton for manual actuation of the contacts and operating position display. Width 17,5 mm. Type IK 8701.13 Manufactured by: E. DOLD & SÖHNE KG Switching relay according to EN 61 810-1 to be built in consumer units, 4 changeover contacts, thermal current 16 A, pushbutton for manual actuation of the contacts and operating position display. Width 17,5 mm. Type IK 8701.14 Manufactured by: E. DOLD & SÖHNE KG 3
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →