ICB18S30F05PO
PROX INDUCTIVE SENSOR, 5MM, PNP/SPST-NO
- Manufacturer: CARLO GAVAZZI
- Product type: Inductive Proximity Sensors
- Sensor Type:Inductive Proximity Sensor; Operating Temperature Max:70°C; Supply Voltage Min:10VDC; Supply Voltage Max:36VDC; Sensor Output Type:3-Wire, PNP, NO; 91Y1055
- SVHC: No SVHC (21-Jan-2025)
- IP Rating: IP67
- Sensor Type: Inductive Proximity Sensor
- Product Range: ICB Series
- Sensor Terminals: Cable
- Sensing Range Max: 5mm
- Sensor Output Type: 3-Wire, PNP, NO
- Supply Voltage Max: 36VDC
- Supply Voltage Min: 10VDC
- Sensing Distance Max: -
- Sensing Distance Min: -
- Sensing Distance Nom: 5mm
- Sensor Body Material: Brass
- Thread Size - Metric: M18 x 1
- Sensor Case / Package: Cylindrical M18 Thread
- Supply Voltage DC Max: 36V
- Supply Voltage DC Min: 10V
- Operating Temperature Max: 70°C
- Operating Temperature Min: -25°C
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 59.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Proximity Inductive SensorsICB, M18 Standard Range, Nickel-Plated Brass Housing Types ICB, M18** - **Sensing distance: 5 to 8 mm** - **Flush or non-flush types** - **Short or long body versions** - **Rated operational voltage (Ub): 10 - 36 VDC** - **Output: DC 200 mA, NPN or PNP** - **Normally open or Normally closed** - **LED indication for output ON** - **Protection: reverse polarity, short circuit, transients** - **Cable or M12 plug versions** - **According to IEC 60947-5-2** - **Laser engraved on front cap, permanently legible** - **CSA certified for Hazardous Locations** ## **Product Descri tion p** ## **Orderin Ke g y** **ICB18S30F05NOM1** A family of inductive proxOutput is open collector **Type** imity switches in industriNPN or PNP transistors. **Housing style** al ~~|~~ standard nickel-plated **Housing material** brass housings. They are **Housing size** able to handle applications **Housing length** where high sensing range is **Thread length** requested. **Detection principle Sensing distance Output type Output configuration Connection** ## **T e Selection yp** **ConnecBody Rated Ordering no. Ordering no. Ordering no. Ordering no. tion style operating NPN, PNP, NPN, PNP, distance Sn Normally open Normally open Normally closed Normally closed** Cable Short 5 mm[1)] **ICB18S30F05NO ICB18S30F05PO ICB18S30F05NC ICB18S30F05PC** Cable Short 8 mm[2)] **ICB18S30N08NO ICB18S30N08PO ICB18S30N08NC ICB18S30N08PC** Plug Short 5 mm[1)] **ICB18S30F05NOM1 ICB18S30F05POM1 ICB18S30F05NCM1 ICB18S30F05PCM1** Plug Short 8 mm[2)] **ICB18S30N08NOM1 ICB18S30N08POM1 ICB18S30N08NCM1 ICB18S30N08PCM1** Cable Long 5 mm[1)] **ICB18L50F05NO ICB18L50F05PO ICB18L50F05NC ICB18L50F05PC** Cable Long 8 mm[2)] **ICB18L50N08NO ICB18L50N08PO ICB18L50N08NC ICB18L50N08PC** Plug Long 5 mm[1)] **ICB18L50F05NOM1 ICB18L50F05POM1 ICB18L50F05NCM1 ICB18L50F05PCM1** Plug Long 8 mm[2)] **ICB18L50N08NOM1 ICB18L50N08POM1 ICB18L50N08NCM1 ICB18L50N08PCM1** 1) For flush mounting in metal 2) For non-flush mounting in metal ## **S ecifications p** |**Specifications**|| |---|---| |**Rated operational voltage (Ub**)10 to 36 VDC|10 to 36 VDC(ripple incl.)| |**Ripple**|≤ 10%| |**Output current (Ie)**|≤ 200 mA @ 50°C<br>(≤ 150 mA @ 50-70°C)| |**OFF-state current** **(Ir)** <br>**No load supply current** **(Io)**<br>**Voltage drop (Ud) **<br>**Protection**<br>**Voltage transient**<br>**Power ON delay (tv)**|≤ 50μA<br>≤ 15 mA<br>Max. 2.5 VDC @ 200 mA<br>Reverse polarity,<br>short-circuit,transients<br>1 kV/0.5 J<br>≤ 20 ms| |**Operating frequency (f)**|≤ 1500 Hz| |**Indication for output ON**|Activated LED, yellow| |NO version<br>NC version|Target present<br>Target not present| |**Indication for short circuit/**|| |---|---| |**overload**|LED blinking (f = 2 Hz)| |**Assured operating**|| |**sensing distance(Sa) **|0 ≤ Sa≤ 0.81 x Sn| |**Effective operating**|| |**distance(Sr) **|0.9 x Sn≤ Sr≤ 1.1 x Sn| |**Usable operating distance(Su) **|0.9 x Sr≤ Su≤ 1.1 x Sr| |**Repeat accuracy (R) **|≤ 10%| |**Differential travel (H)**|| |(Hysteresis)|1 to 20% of sensingdist.| |**Ambient temperature**|| |Operating|-25° to +70°C (-13° to +158°F)| |Storage|-30° to +80°C(-22° to +176°F)| |**Shock and vibration**|IEC 60947-5-2/7.4| |**Housing material**|| |Body|Nickel-plated brass| |Front|Grey thermoplastic polyester| **1** Specifications are subject to change without notice (16.01.2017) **ICB, M18** ## **Specifications (cont.)** |**Connection**||| |---|---|---| |Cable||Ø4.1 x 2 m, 3 x 0.25 mm2,| |Plug||grey PVC, oil proof<br>M12 x 1| |**Degree ofprotection**||IP 67| |**Weight**(cable/nuts included)||| |Cable||Max. 150 g| |Plug||Max. 70g| |**Dimensions**<br>**Tightening torque**<br> Non-flush version<br>Flush version|**Tightening torque**<br>Non-flush version|See diagrams below<br>25 Nm| |From 0 to 7 mm||20 Nm| |> 7 mm||25 Nm| |**Approvals**|**cULus**|(UL508)| ||**cCSAus**|As Process Control| |||Equipment for Hazardous| |Note: The terminal connector||Locations.| |(version ...M1) was not||- Class I, Division 2,| |evaluated. The suitability of||Groups A, B, C and D.| |the terminal connector should||-T5 up to 150 mA, T4A for a| |be determined in the end-use||load current > 150 mA and| |application.||up to 200 mA, Enclosure| |||Type 4.| **Approvals (cont.)** Ambient temperature Ta: -25° to +60°C CCC is not required for products with a maximum operating voltage of ≤ 36 V **EMC protection** According to IEC 60947-5-2 IEC 61000-4-2 (ESD) 8 KV air discharge, 4 KV contact discharge IEC 61000-4-3 3 V/m IEC 61000-4-4 2 kV IEC 61000-4-6 3 V IEC 61000-4-8 30 A/m **MTTFd** 850 years @ 50°C (122°F) ## **Dimensions (mm)** **==> picture [230 x 329] intentionally omitted <==** **----- Start of picture text -----**<br> 7.5 LED<br>30.0 20.1<br>53.0<br>Short body, flush version, cable<br>S S<br>7.5 LED (4 x 90°)<br>4 3<br>1 2<br>30.0<br>54.0<br>Short body, flush version, plug<br>7.5 LED<br>50.0<br>73.1<br>Long body, flush version, cable<br>M18x1<br>M18x1<br>M18x1<br>**----- End of picture text -----**<br> **==> picture [156 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> 7.5 LED<br>10.0 30.0 20.1<br>63.0<br>Short body, non-flush version, cable<br>M18x1<br>**----- End of picture text -----**<br> **==> picture [225 x 206] intentionally omitted <==** **----- Start of picture text -----**<br> 7.5 LED (4 x 90°)<br>4 3<br>1 2<br>10.0 30.0<br>64.0<br>Short body, non-flush version, plug<br>7.5 LED<br>10.0 50.0<br>83.1<br>Long body, non-flush version, cable<br>M18x1<br>M18x1<br>**----- End of picture text -----**<br> **2** Specifications are subject to change without notice (16.01.2017) **ICB, M18** ## **Dimensions (mm) (cont.)** **==> picture [492 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> 7.5 LED (4 x 90°) 7.5 LED (4 x 90°)<br>4 3 4 3<br>1 2 1 2<br>50.0 10.0 50.0<br>74.0 84.0<br>Long body, flush version, plug Long body, non-flush version, plug<br>M18x1 M18x1<br>**----- End of picture text -----**<br> ## **Installation** Flush sensor, when installed in damping material, must be according to Picture 1A. **==> picture [180 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 1A<br>Free zone or<br>≥ 3 x Sn non-damping<br>d<br>material<br>Sn : nominal sensing distance<br>d : sensor diameter (18 mm)<br>**----- End of picture text -----**<br> Non-flush sensor, when installed in damping material, must be according to Picture 1B. **==> picture [210 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 1B<br>Free zone or<br>≥ 3 x d<br>≥ 3 x Sn non-damping<br>d<br>material<br>Sn : nominal sensing distance<br>d : sensor diameter (18 mm)<br>≥ 2 x Sn<br>**----- End of picture text -----**<br> Flush sensors, when installed together in damping material, must be according to Picture 2A. **==> picture [150 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 2A<br>d d d<br>d : sensor diameter (18 mm)<br>**----- End of picture text -----**<br> Non-flush sensors, when installed together in damping material, must be according to Picture 2B. **==> picture [192 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 2B<br>d d 2 x d d d<br>d : sensor diameter (18 mm)<br>**----- End of picture text -----**<br> For sensors installed opposite each other, a minimum space of 6 x Sn (the nominal sensing distance) must be observed (See Picture 3). **Picture 3** **==> picture [99 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> ≥ 6 x Sn<br>Sn : nominal sensing distance<br>**----- End of picture text -----**<br> **3** Specifications are subject to change without notice (16.01.2017) **ICB, M18** ## **Wiring Diagram** **==> picture [481 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 1 BN + 1 BN + 1 BN + 1 BN +<br>4 BK<br>2 BK 2 BK<br>4 BK<br>3 BU 3 BU<br>- - 3 BU 3 BU<br>an ;7 LV, - x0, -<br>NPN - Normally open NPN - Normally closed PNP - Normally open PNP - Normally closed<br>**----- End of picture text -----**<br> ## **Reduction Factors** The rated operating distance is reduced by the use of metals and alloys other than Fe360. The most important reduction factors for inductive proximity sensors are shown in Picture 4. **Picture 4 Fe360 : Steel CrNi : Chrome-nickel CuZn : Brass Al : Aluminium** St approx. (%] **Cu : Copper** 100 | Fe360 **Sr : Effective operating distance** ## **Accessories for Plu Versions g** **PVC PUR** 3-wire angled connector, 2 m cable **CONB13NF-A2 CONB13NF-A2P** 3-wire angled connector, 5 m cable **CONB13NF-A5 CONB13NF-A5P** 3-wire angled connector, 10 m cable **CONB13NF-A10 CONB13NF-A10P** ~~CO~~ 3-wire angled connector, 15 m cable **CONB13NF-A15 CONB13NF-A15P** ~~<a~~ 3-wire straight connector, ~~e~~ 2 m cable **CONB13NF-S2 CONB13NF-S2P** ~~Cee~~ 3-wire straight connector, 5 m cable **CONB13NF-S5 CONB13NF-S5P** ~~—________] nnn~~ 3-wire straight connector, 10 m cable **CONB13NF-S10 CONB13NF-S10P** ~~ne~~ 3-wire straight connector, ~~——iSY~~ 15 m cable **CONB13NF-S15 CONB13NF-S15P** ## **Deliver Contents y** - Inductive proximity switch ICB. - 2 nuts NPB **For any additional information or different options, please refer to the “General Accessories - Connector Cables -Type CONB1...” datasheets.** - Packaging: plastic bag **4** Specifications are subject to change without notice (16.01.2017)
Updated at April 21, 2026
Founded in Milan in 1931, Carlo Gavazzi is a globally recognized leader in the design and manufacture of high-quality automation components. For nearly a century, the company has driven technological innovation in the industrial and building automation markets. With ISO 9001-certified production facilities across Europe and Asia, Carlo Gavazzi delivers state-of-the-art solutions tailored for demanding applications, including HVAC, renewable energy, semiconductor manufacturing, and electric vehicle charging infrastructure. Our extensive portfolio of Carlo Gavazzi components focuses heavily on their industry-leading switching and sensing technologies. We carry a comprehensive selection of solid state relays, contactors, and power relays engineered for exceptional reliability and thermal performance. Alongside these robust switching solutions, our range features a wide array of precision sensors, with a strong emphasis on proximity switches and light sensors that are critical for automated manufacturing processes, mobile equipment, and access control systems. Beyond core sensing and switching, the Carlo Gavazzi lineup extends into essential power management, circuit protection, and control devices. This includes highly efficient AC/DC converters, thermal magnetic circuit breakers, and advanced panel instrumentation designed to monitor and optimize energy efficiency. From current sensing transformers to motor starters, engineers consistently trust Carlo Gavazzi to provide competitive, dependable, and forward-thinking components for their most complex automation challenges.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.