Image not available
Illustrative purposes only
ICB12LN04NOM1
INDUCTIVE PROXIMITY SENSORS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type: Capacitive Proximity Sensors
- SVHC: No SVHC (21-Jan-2025)
- Product Range: ICB Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 140.49 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Proximity Inductive Sensors Standard range, Nickel-Plated Brass Housing Types ICB, M12** - **Sensing distance: 2 to 4 mm** - **Flush and non-flush types** - **Short and long body versions** - **Rated operational voltage (Ub): 10 - 36 VDC** - **Output: DC 200 mA, NPN or PNP** - **Normally open, Normally closed** - **LED indication for output ON** - **Protection: reverse polarity, short circuit, transients** - **Cable and M12 plug versions** - **According to IEC 60947-5-2** - **Higher resistance to magnetic field** - **CSA certified for Hazardous Locations** ## **Product Descri tion p** A family of inductive proximity switches in industrial standard nickel-plated brass housings. They are able to handle applica tions where high sensing range is requested. Output is open collector NPN or PNP transistors. ## **Ordering Key ICB12SF02NOM1** **Type Housing style Housing material Housing size Housing length Detection principle Sensing distance Output type Output configuration Connection** ## **T e Selection yp** **Connec- Body Rated Ordering no. Ordering no. Ordering no. Ordering no. tion style operating NPN PNP NPN PNP distance S** n **Normally open Normally open Normally closed Normally closed** Cable Short 2 mm[1)] **ICB 12 SF 02 NO ICB 12 SF 02 PO ICB 12 SF 02 NC ICB 12 SF 02 PC** Cable Short 4 mm[2)] **ICB 12 SN 04 NO ICB 12 SN 04 PO ICB 12 SN 04 NC ICB 12 SN 04 PC** Plug Short 2 mm[1)] **ICB 12 SF 02 NOM1 ICB 12 SF 02 POM1 ICB 12 SF 02 NCM1 ICB 12 SF 02 PCM1** Plug Short 4 mm[2)] **ICB 12 SN 04 NOM1 ICB 12 SN 04 POM1 ICB 12 SN 04 NCM1 ICB 12 SN 04 PCM1** Cable Long 2 mm[1)] **ICB 12 LF 02 NO ICB 12 LF 02 PO ICB 12 LF 02 NC ICB 12 LF 02 PC** Cable Long 4 mm[2)] **ICB 12 LN 04 NO ICB 12 LN 04 PO ICB 12 LN 04 NC ICB 12 LN 04 PC** Plug Long 2 mm[1)] **ICB 12 LF 02 NOM1 ICB 12 LF 02 POM1 ICB 12 LF 02 NCM1 ICB 12 LF 02 PCM1** Plug Long 4 mm[2)] **ICB 12 LN 04 NOM1 ICB 12 LN 04 POM1 ICB 12 LN 04 NCM1 ICB 12 LN 04 PCM1** 1) For flush mounting in metal 2) For non-flush mounting in metal ## **S ecifications p** |**Specifications**|| |---|---| |**Rated operational voltage** (Ub)|10 to 36 VDC(ripple incl.)| |**Ripple**|**le**≤10%| |**Output current**(Ie) <br>|≤200 mA @ 50°C<br> (≤150 mA @ 50-70°C)| |**OFF-state current(Ir)** <br>**No load supply current**(IO) <br>**Voltage drop **(Ud) <br>**Protection**<br>short-circuit<br>**Voltage transient** 1 kV/0.5 J<br>**Power ON delay **(tv) 300 ms|≤50µA<br> ≤15 mA<br> Max. 2.5 VDC @ 200 mA<br>**Protection**Reverse polarity,<br>short-circuit,transients<br>1 kV/0.5 J<br>300 ms| |**Operating frequency **(f)|≤2000 Hz| |**Indication for output ON**|**Indication for output ON**Activated LED, yellow| |NO version Target present<br>NC version Target not present|Target present<br>NC version Target not present| |**Indication for short circuit/**|| |---|---| |**overload **|LED blinking| |**Assured operating**|| |**sensing distance**(Sa)|0≤Sa≤0.81 x Sn| |**Effective operating**|| |**distance**(Sr) 0.9 x S|0.9 x Sn≤Sr≤1.1 x Sn| |**Usable operating distance**(Su)0.9 x S|0.9 x Sr≤Su≤1.1 x Sr| |**Repeat accuracy **(R)|≤10%| |**Differential travel**(H)|| |(Hysteresis)|1 to 20% of sensingdist.| |**Ambient temperature**|| |Operating|Operating-25° to +70°C (-13° to +158°F)| |Storage|-30° to +80°C(-22° to +176°F)| |**Shock and vibration**IEC 60947-5-2/7.4|IEC 60947-5-2/7.4| |**Housing material**|| |Body Nickel-plated brass|Nickel-plated brass| |Front|Grey thermoplastic polyester| **1** Specifications are subject to change without notice (06.02.14) **ICB, M12** ## **Specifications (cont.)** |**Connection**|| |---|---| |Cable 2 m, 3 x 0.25 mm|Cable 2 m, 3 x 0.25 mm2,| |grey PVC, oil proof|grey PVC, oil proof| |PlugM12 x 1<br>**Degree ofprotection**<br>**Weight**(cable/nuts included) <br>Cable Max. 120 g<br>PlugMax. 30|M12 x 1<br>**rotection**IP 67 <br>Cable Max. 120 g <br>Max. 30g| |**Dimensions **|See diagrams below| |**Tightening torque** <br>Distance from sensing face<br>from 2 mm to 5 mm 4 Nm<br>> 5 mm 10 Nm|Distance from sensing face<br>4 Nm<br>10 Nm| |**Approvals**|| |**UL (CRUUS), CSA** As Industrial Control|As Industrial Control| |Equipment - Proximity|Equipment - Proximity| |Switches.|Switches.| |Types 1, 4, 4X or 12.|Types 1, 4, 4X or 12.| |Max ambient temperature|Max ambient temperature| |40°C.|40°C.| ## **Approvals (cont.)** **CCSAUS** As Process Control Equipment for Hazardous Locations. **Note:** The terminal connector Locations. (version ...M1) was not evalu- Class I, Division 2, ated. The suitability of the terGroups A, B, C and D. minal connector should be - T5, Enclosure Type 4. determined in the end-use Ambient temperature application. Ta: -25° to +60°C. **CE-marking** Yes **EMC protection** According to IEC 60947-5-2 IEC 61000-4-2 (ESD) 8 KV air discharge, 4 KV contact discharge IEC 61000-4-3 3 V/m IEC 61000-4-4 2 kV IEC 61000-4-6 3 V IEC 61000-4-8 30 A/m ## **Dimensions** **==> picture [483 x 227] intentionally omitted <==** **----- Start of picture text -----**<br> 50 50<br>O S se | glee<br>1 32 8 25<br>LED Els LED ele<br>p> p><br>Short body, flush version, cable Short body, non-flush version, cable<br>51 51<br>4 3 4 3<br>1 2 1 2<br>Hit s eal i : — Hii} bal | :<br>1 a 30 ae 11 a 8 23 ae 11<br>LED LED<br>Short body, flush version, plug Short body, non-flush version, plug<br>**----- End of picture text -----**<br> **==> picture [228 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> 4 3<br>1 2<br>1 a 30 ae 11<br>LED<br>Short body, flush version, plug<br>**----- End of picture text -----**<br> **==> picture [194 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> ST 65<br>1 47<br>LED<br>Long body, flush version, cable<br>**----- End of picture text -----**<br> **==> picture [191 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> ns 65<br>8 40<br>LED<br>Long body, non-flush version, cable<br>**----- End of picture text -----**<br> **2** Specifications are subject to change without notice (06.02.14) **ICB, M12** ## **Dimensions (cont.)** **==> picture [490 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> 66 66<br>4 3 4 3<br>1 2 1 2<br>1 _rr 45 LED eK 11 ee 8 38 LED ee 11<br>Long body, flush version, plug Long body, non-flush version, plug<br>**----- End of picture text -----**<br> ## **Installation** Flush sensor, when installed in damping material, must be according to Picture 1A. **==> picture [194 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 1A<br>Free zone or non-<br>≥ 3 x Sn damping material<br>|<br>Sn : nominal sensing distance<br>d : sensor diameter<br>**----- End of picture text -----**<br> Non-flush sensor, when installed in damping material, must be according to Picture 1B. **==> picture [230 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 1B<br>≥ 3 x Sn ≥ 4 x dd damping materialFree zone or non-<br>Sn : nominal sensing distance<br>d : sensor diameter<br> 2 x Sn<br>≥<br>**----- End of picture text -----**<br> Flush sensors, when installed together in damping material, must be according to Picture 2A. **==> picture [187 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 2A<br>— d d d<br>d : sensor diameter<br>**----- End of picture text -----**<br> Non-flush sensors, when installed together in damping material, must be according to Picture 2B. **==> picture [172 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 2B d d<br>4 4 x d<br>d : sensor diameter<br>**----- End of picture text -----**<br> For sensors installed opposite each other, a minimum space of 6 x Sn (the nominal sensing distance) must be observed (See Picture 3). **==> picture [173 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> Picture 3<br>6 x Sn<br>Sn : nominal sensing distance<br>**----- End of picture text -----**<br> **3** Specifications are subject to change without notice (06.02.14) **ICB, M12** ## **Wiring Diagrams** **==> picture [220 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> 1 BN + 1 BN +<br>2 WH BK<br>4 BK<br>3 BU 3 BU<br>- -<br>NPN - Normally open NPN - Normally closed<br>**----- End of picture text -----**<br> ## **Reduction factors** The rated operating distance is reduced by the use of metals and alloys other than Fe360. The most important reduction factors for inductive proximity sensors are shown in Picture 4. **Picture 4 Fe360 : Steel CrNi : Chrome-nickel** Sr approx. (%) **CuZn : Brass** 100 Fe360 **Al : Aluminium Cu : Copper Sr : Effective operating distance** **==> picture [222 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> 1 BN + 1 BN +<br>4 BK<br>2 WH BK<br>3 BU 3 BU<br>- -<br>PNP - Normally open PNP - Normally closed<br>**----- End of picture text -----**<br> ## **Accessories for Plu Versions g** 3-wire angled connector, 2 m cable **CONM13NF-A2** 3-wire angled connector, 5 m cable **CONM13NF-A5** 3-wire angled connector, 10 m cable **CONM13NF-A10** 3-wire stright connector, 2m cable **CONM13NF-S2** ~~TT~~ 3-wire stright connector, 5m cable **CONM13NF-S5** **For any additional information or different options, please refer to the “General Accessories” datasheets.** ## **Deliver Contents y** - Inductive proximity switch ICB. - 2 nuts NPB - Packaging: plastic bag **4** Specifications are subject to change without notice (06.02.14)
Updated at April 26, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →