Image not available
Illustrative purposes only
HY 10-P
Current Transducer, HY Series, 10A, -30A to 30A, 1 %, Voltage Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-30A to 30A; Current Measuring Range AC:-30A to 30A; Response Time:3µs; Accuracy %:1%; Prod
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 1%
- Accuracy %: 1%
- Product Range: HY Series
- Response Time: 3µs
- Primary Current: ± 10A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: ± 12V to ± 15V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 80°C
- Operating Temperature Min: -10°C
- Current Measuring Range AC: -30A to 30A
- Current Measuring Range DC: -30A to 30A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 15.23 € |
| Current stock | 100+ |
| Lead time | 30 days |
## **Current Transducer HY 5 ... 25-P** ## _I_ **= 5 ... 25 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data**~~ |Primary nominal Primary current|Primary nominal Primary current|Primary|Primary|**Type**|**RoHS since**|**RoHS since**| |---|---|---|---|---|---|---| |RMS current<br> measuring range||measuring range<br>conductor|||date code|| |_I_P N(A)|(A)<br> _I_P M(A)||(mm)|||| |5|±15||⌀0.7|**HY 5-P**|45260|| |10|10<br>±30||⌀1.1|**HY 10-P**|45286|| |12.5<br>±37.5|||⌀1.4|**HY 12-P**|45264|| |15|15<br>±45||⌀1.4|**HY 15-P**|45276|| |20|20<br>±60|2 ×|2 ×⌀1.21)|**HY 20-P**|46097|| |25|25<br>±75|2 ×|2 ×⌀1.41)|**HY 25-P**|45269|| |_U_out|Output voltage (Analog) @_I_P N,_R_L= 10 kΩ,_T_A= 25 ° C||||±4|V| |_Î_P max|Primary withstand peak current (1 ms)||Primary withstand peak current (1 ms)||50 ×_I_P N|| |_R_INS|Insulation resistance @ 500 V DC||Insulation resistance @ 500 V DC||> 1000|MΩ| |_R_L|Load resistance||||> 1|kΩ| |_R_out|Output internal resistance||||100|Ω| |_U_C|Supply voltage (±5 %)2)||||±12 ... 15 V|±12 ... 15 V| |_I_C|Current consumption||||±10|mA| ## ~~**Accuracy - Dynamic performance data**~~ _ε_ Error @ _I_ P N, _T_ A = 25 ° C (excluding offset) < ±1 % _ε_ L Linearity error[3)] (0 .. ± _I_ P N) < ±1 % of _I_ P N _TCU_ O E Temperature coefficient of _U_ O E typical ±1.5 mV/K max ±3 mV/K _TCU_ out Temperature coefficient of _U_ out (% of reading) < ±0.1 %/K _U_ O E Electrical offset voltage @ _T_ A = 25 °C < ±40 mV _U_ O M Magnetic offset voltage @ _I_ P = 0, after an excursion of 1 × _I_ P N < ±15 mV _t_ D 90 Delay time to 90 % of the final output value for _I_ P N step[4)] HY 25-P < 5 µs others < 3 µs _BW_ Frequency bandwidth (−3 dB)[5)] DC ... 50 kHz ~~**General data**~~ _T_ A Ambient operating temperature −10 ... +80 °C _T_ A st Ambient storage temperature −25 ... +85 °C _m_ Mass < 14 g Standard[6)] EN 50178: 1997 ## **Features** - ●Hall effect measuring principle - ●Compact design for PCB mounting - ●Low power consumption - ●Extended measuring range (3 × _I_ P N) - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Easy mounting - ●Small size and space saving - ●Only one design for wide current ratings range - ●High immunity to external interference. ## **Applications** - ●Static converters for DC motor drives - ●Switched Mode Power Supplies (SMPS) - ●AC variable speed drives - ●Uninterruptible Power Supplies (UPS) - ●Battery supplied application - ●General purpose inverters. ## **Application Domain** - ●Industrial. Notes:[1) ] Conductor terminals are soldered together - 2) Operating at ±12 V ≤ _U_ C < ±15 V will reduce measuring range - 3) Linearity data exclude the electrical offset > 4) For a d _i/_ d _t_ = 50 A/µs - 5) Please refer to derating curves in the technical file to avoid excessive core heating at - high frequency - 6) Please consult characterisation report for more technical details and application advice. 74.73.08.000.0, 74.73.13.000.0, 74.73.14.000.0, 74.73.15.000.0, 74.73.17.000.0, 74.73.19.000.0 Page 1/4 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 1March2021/Version 11 ## **Current Transducer HY 5 ... 25-P** ## ~~**Insulation coordination**~~ |_U_d|RMS voltage for AC insulation test, 50 Hz, 1 min|2.5|kV| |---|---|---|---| |_U_Nm|Rated insulation RMS voltage|5001)|V| Note:[1) ] Pollution class 2, overvoltage category III. ## **UL 508: Ratings and assumptions of certification** File # E189713 Volume: 2 Section: 1 ## **Standards** - ●Standard for Industrial Control Equipment UL 508, Seventeeth Edition - ●Canadian Standard for Industrial Control Equipment CSA C22.2 No. 14-10, Eleventh Edition ## **Ratings** **==> picture [381 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Value<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Value**| |---|---|---|---| ||||| |Max surrounding air temperature|_T_A|°C|40| |Primary current|_I_P|A|According to series primary currents| |Secondary supply voltage|_U_C|V DC|0 to ±15| |Output voltage|_U_out|V DC|0 ... 4| ## **Conditions of acceptability** When installed in the end-use equipment, consideration shall be given to the following: - _1 - These devices must be mounted in a suitable end-use enclosure._ - _2 - The terminals have not been evaluated for field wiring._ - _8 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other than through the grounding means)._ ## **Marking** Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under UL’s Follow-Up Service. Always look for the Mark on the product. Page 2/4 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 1March2021/Version 11 ## **Safety** This tran _sducer_ must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. ## Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (e.g. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 3/4 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 1March2021/Version 11 ## **Dimensions HY 5 .. 25-P** (in mm) **==> picture [310 x 354] intentionally omitted <==** **----- Start of picture text -----**<br> 36.0 Max.<br>32.0 Max. HY 5 to 15-P<br>J<br>JAPAN<br>18.0 12 Max.<br>12.0<br>_— ——<br> HY 5-P<br> 45059<br>H Y 10 - P<br>3 CE JP29639 a]<br>« _ We _|<br>: | he l | [<br>(0.5) ( d) (0.3)<br>3 x 2.54 10±0.3 8.5±0.3 (a)±0.3<br>3.9±0.3 Pins Arrangement<br>1 2 3 4 5 6<br>1 +15 V<br>HY 20 to 25-P HY 20 - P PIN ARRANGEMENT 2 -15 V<br>9639 3 OUTPUT<br>1 +15V<br>2 --15V 4 0 V<br>Connection 3 OUTPUT<br>4 0V<br>PYTyy de 5 PRIMARY IN<br>3±0.5 ( dx2) 5 PRIMARY IN 6 PRIMARY OUT<br>3 x 2.54 10±0.3 8.5±0.3 6 PRIMARY OUT<br>PCB MOUNTING DIMENSIONS (in mm ±0.1, hole -0, +0.2)<br>2 holes dia. (e)<br>HY 5 to15-P 9364 O—-b— +<br>3 x 2.54 10 8.5<br>HY 20 to 25-P 4 holes dia 1 holes dia (e) TypeHY 05-P mm1.1a mm0.7d mme1.2 mmg--<br>HY 10-P 1.4 1.1 1.6 --<br>HY 12-P 1.5 1.4 2.0 --<br>(g) (g) HY 15-P 1.5 1.4 2.0 --<br>HY 20-P 1.4 1.2 1.8 1.4<br>3 x 2.54 10 8.5 HY 25-P 1.5 1.4 2.0 1.6<br>**----- End of picture text -----**<br> ## **Remark** - ●Temperature of the primary conductor should not exceed 100°C. Page 4/4 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 1March2021/Version 11
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →